Safety Testing Trip Report
BLACK & VEATCH
FEDERAL SERVICES DIVISION
Black & Veatch 1 Date 7/7/2011
ENGINEERING REPORT
Purpose: Perform various tests to confirm impacts of the fish barrier operation on structures and areas around the Demonstration, IIA, and IIB barriers.
Date: June 13-16, 2011
Location: Romeoville, IL
Point of Contact: Joseph W. Schulenberg, USACE – Chicago District
Attachments: A: Site overview map, B: Parasitic Testing Data/Barrier Operation Data, C: Field Mapping Data, and D: Continuous Monitoring Data/Pictures/Additional Testing Information/Lat- Long Coordinates
Overiew: This trip report is subsequent to a series of previous reports submitted on February 19, 2010 titled CURRENTS INVESTIGATION DRAFT REPORT, September 21, 2010 titled CURRENTS
INVESTIGATION FINAL REPORT, and a final May 10, 2011 report titled TAR 24 - SAFETY
TESTING FINAL REPORT. These reports document various field investigations, technical evaluations, alternatives development, and other research associated with the operation of the fish barriers in Romeoville, IL. These reports document methods to mitigate the stray currents, methods to mitigate corrosion, the test results, the electrical modeling results and the various research that has been performed to understand the issues occurring around the barrier site. This report is a continuation of the previous reports.
This report includes the documentation of the daily activities performed by the test team while at the site during the week of June 13th, 2011. The information in this report includes documentation of the field test methods and procedures, presentation of the data recorded, analysis of that data, and additional onsite information observed by the testing team. There are several
Attachments that include the recorded field mapping data, parasitic testing data, map of point’s measured, continuous monitoring information, and barrier operation data.
1. Observations
The site has changed significantly since the February 2011 field testing investigation.
Several of the points used to record electrical data have been removed due to site modifications.
Black & Veatch 2 Date 7/7/2011
Following is a brief list of the site changes found.
New Fencing – Changes to the fencing was found through out the site. Fencing near point 168 and around point 21 has been revised.
Signage where previous measurements were recorded has been moved. An example of this was found at 603 and point 78.
Jersey barriers at point 406 have been removed.
Multiple points have been removed because of construction or modifications onsite. Examples of these are points are 603, 406, and 712.
Residences have installed additional grounding.
Gate at point 1 has had grounding jumper removed.
Barrier 2A was not operational.
Parasitic 2 was damaged and not operational.
In addition to site modifications, the weather was significantly different than the weather during the February 2011 field testing. The air temperature was in the 80’s for the duration of the trip. The first two days were sunny, while the last two days were cloudy and rainy. The soil was moist and was less resistive than the February 2011 field testing.
2. Methods and Procedures:
Testing began by establishing continuous monitoring stations at five different locations at the fish barriers. Meters were used to continuously record voltage potentials and capture changes due to barrier operation, parasitic changes, or effects from other testing taking place on site. Fluke
Scopemeters, powered by portable generators, recorded the trends of maximum root mean squared voltage. Points where continuous monitoring was located included 421.3 (touch to light pole in front of 805 E. Old Romeo Rd.), 429A (touch to utility meter box at 805 E. Old Romeo Road), 32 (touch to bridge abutment), 7 (perpendicular step near barrier IIB), and point 78 (perpendicular step near
IIA). These points were monitored starting at the beginning of testing around seven in the morning and recorded until the end of testing at approximately five in the afternoon each day.
After continuous monitoring was set up, field mapping began. The Black & Veatch safety testing team was responsible for 56 different points across the fish barrier site. These points were measured twice a day, morning and afternoon, creating over 100 different data logs for each day. At each point three different measurements and up to three different orientations were recorded totaling around 1000 different daily entries. Orientations included touch, perpendicular step, and parallel
Black & Veatch 3 Date 7/7/2011 step readings. For each of these readings, three different voltages were recorded: Peak-Peak Voltage
(VPk-Pk), Root Mean Squared Voltage (VRMS), and Direct Current Voltage (VDC). Each recording was logged in a notebook and analyzed. All point locations for continuous monitoring and field mapping can be found on the site overview map in Attachment A. These recorded values were verified using multiple meters, reference electrodes, and spot checks during field mapping.
3. Data Recorded:
A full list of recorded values can be found in attachment’s C and D.
Maximum VRMS Values by Step/Touch/Reach:
Parallel Step – 5.6V – Point 21 on 6/15 at 1531 hours Perpendicular Step – 8.5V – Point 404 on 6/14 at 745 hours Touch – 42.5V – Point 21 on 6/13 at 1030 hours Reach – 5.85V – Point 1 on6/14 at 1514 hours
Maximum VRMS Value at OXBOW (disconnected from utility):
Touch – 0.12V – Service Meter on 6/13 at 927 hours
Maximum VRMS Value at Marine Material Handling:
Touch – 1.04V – Service Meter on 6/14 at 1005 hours
Maximum VRMS Value on Fence, Bollards, Rails, Seal, and Barb wire:
Touch to Bollard – 16.8V – Point 718 on 6/15 at 1523 hours Touch to Guard Rail – 33V – Point 719 on 6/14 at 1023 hours Touch to Fence – 19.2V – Point 91 on 6/16 at 955 hours Touch to Door Seal – 35.5V – Point 717 on 6/13 at 1005 hours Touch to Barb Wire – 5.4V – Point 719 on 6/14 at 1025 hours
Maximum VRMS Value on BNSF Sheds:
Touch to Metal Building – 0.53V – Point 715 on 6/13 at 956 Touch to Control Enclosure – 0.52V – Point 716 on 6/14 at 1403
Maximum VRMS Value with Barge in the Water (Collision Testing):
Touch – 33.5V – Point 21, Grounding on Power Pole on 6/16 at 1006 hours
Black & Veatch 4 Date 7/7/2011
Maximum VRMS Value with Parasitic Operation (1&3 connected OR all off):
1&3 -Touch – 42.5V – Point 21, Grounding on Power Pole on 6/13 at 1030 hours All OFF – Touch – 10.54V – Point 46 on 6/14 at 1535 hours
Maximum VRMS Value with Barrier Operation (2.0 and 2.3 V/in):
2.3 – Touch – 42.5V – Point 21, Grounding on Power Pole on 6/13 at 1030 hours
2.0 – Touch – 33.5V – Point 21, Grounding on Power Pole on 6/16 at 1006 hours
Maximum VRMS Value Recorded on at Continuous Monitoring Points:
Point 7 – Step – 14.5V – Taken on 6/14 at around 830 hours
Black & Veatch 5 Date 7/7/2011
Point 32 – Touch – 5.2V – Taken on 6/16 at around 923 hours
Point 421.2 – Touch – 14.5V – 1)Taken on 6/13 at 1224 hours & 2) 6/14 at 1140, 1158, and 1340 hours
Black & Veatch 6 Date 7/7/2011
Point 421.3 – Touch – 8.3V – Taken on 6/16 at 1000 hours
Black & Veatch 7 Date 7/7/2011
Point 429A – Touch – 0.755V – Taken on 6/14 at 1215 hours
4. Interpretation of Data:
The recorded data confirmed trends that were noticed during the February 2011 field testing.
Direct comparison of the data is difficult due to the changes in the site, and the climate between the two testing periods. The analysis of the data focused on the barrier operation, parasitic orientations, and effects of a barge in the water to ground field mapping. In the following comparisons, the only variable that has changed is the variable that is listed. The other variables remained the same.
Barrier Operation (2.0 vs. 2.3 V/in):
2.3 – Point 21 Touch to Guy Wire – 6.34 VRMS
2.0 – Point 21 Touch to Guy Wire – 5.3 VRMS
2.3 – Point 7 Perpendicular Step – 7.57 VRMS
2.0 – Point 7 Perpendicular Step – 6.76 VRMS
2.3 – Point 46 Parallel Step – 3.8 VRMS
2.0 – Point 46 Parallel Step – 3.9 VRMS
The data suggests increasing the barrier output in the canal will increase ground surface voltage potentials. This is congruent with data recorded in February 2011.
Black & Veatch 8 Date 7/7/2011
Barge in the Canal (Yes OR No):
Yes – Point 20 Touch to Fence – 2.75 VRMS No – Point 20 Touch to Fence – 1.17 VRMS
Yes – Point 7 Perpendicular Step – 2.13 VRMS No – Point 7 Perpendicular Step – 2.88 VRMS
Yes – Point 46 Touch to Fence - 3.4 VRMS No – Point 46 Touch to Fence – 4.6 VRMS
Data confirmed discussion from February 2011 that stated ground surface voltage potentials were lower when a barge was in the canal.
Parasitic Orientations (Para 1 and 3 ON, 2 OFF and All OFF):
To determine the effects of parasitic configurations on ground surface voltage potentials, a test was preformed on Wednesday June 15th, 2011 where the parasitic switches were run through a series of scenarios and voltage measurements were recorded. Four points were monitored and the following results were found. Points measured included 78, 7, 9, and 423.3 step Vrms voltage readings. (Note: Trends could not be verified by comparing to data taken in February because the inoperable condition of parasitic 2 and the use of only barrier 2b.)
LIST OF SCENARIOS RUN
Scenarios Parasitic 1 Parasitic 2 Parasitic 3
1 ON ON ON
2 ON ON OFF
3 ON OFF ON
4 OFF ON ON
5 OFF OFF OFF
ACTUAL LIST OF SCENARIOS DUE TO BROKEN PARASITIC 2
Scenarios Parasitic 1 Parasitic 2 Parasitic 3
1 ON OFF ON
2 OFF OFF OFF
3 ON OFF ON
4 OFF OFF OFF
Black & Veatch 9 Date 7/7/2011
POINT 7
POINT 9
Black & Veatch 10 Date 7/7/2011
POINT 423.3
POINT 78
The field testing showed a direct impact on ground surface voltage potentials by adjusting the configuration of the parasitics to north, south, east, and west of the barrier 2B. These changes are
Black & Veatch 11 Date 7/7/2011 documented in the waveforms above. The changes in electrical measurements between scenario 1 and 2 is difficult to explain. The voltage decrease during scenario 1 is not caused by the parasitics.
The changes in the barrier output could have caused these voltage swings. The barrier control room data logs do no t show that any changes in barrier operation were made during this time. In addition, there was no activity in the canal such as tug boats or barges that could have accounted for the decreased voltage.
5. Additional Onsite Testing and Information:
During the safety testing, additional tests outside of the primary field mapping were completed. Additional tests included testing on BNSF equipment, parasitic busbar tests, and busbar readings in building 2A.
BNSF Testing
On June 14th, 2011 at 1100 hours, the Black & Veatch testing team was approached by BNSF personnel performing maintenance on the traffic arms at the Old Romeo Rd crossing. Mr. Arman of the Chicago District was present and B&V’s point of contact, Mr. Schulenberg, was contacted.
Upon receiving permission from the Chicago District and BNSF, several tests were performed to determine the effect of the fish barriers stray current on the BNSF equipment.
BNSF mentioned that the tracks carry 5 different signals, 4 pulsed DC and one AC. The AC signal’s frequency is 156 Hz. Track #2 is the East track and track #1 is the West track. BNSF mentioned that they noticed an elongated waveform on signal #5. B&V requested that the BNSF signals be temporary shut down. The following waveforms were captured.
Black & Veatch 12 Date 7/7/2011
VOLTAGE MEASUREMENTS TAKEN BETWEEN TRACKS – EAST
FREQUENCY MEASUREMENT TAKEN BETWEEN TRACKS - EAST
Black & Veatch 13 Date 7/7/2011
FREQUENCY AND VOLTAGE MEASUREMENT TAKEN BETWEEN TRACKS – WEST
The waveforms indicate that the fish barrier electrical signature is present in the tracks. The data log from the control room shows that barrier 2B was running at 15 Hz when these readings were taken which was confirmed by measurements. It could not be determined whether the barrier signal was interfering with BNSF track signals. Additional testing will need to be performed to determine if the fish barrier signal is disrupting the track signals.
Parasitic Cables
A test to confirm current in the parasitic cables and voltage on the busbar was performed on
Wednesday June 15th, 2011 at 715 hours. The data is listed below. The max voltage recorded was
172 VRMS and the max current found was 75 Amps. See the full list of data below and in attachment
B.
Scenarios Parasitic 1 Parasitic 2 Parasitic 3
1 ON ON ON
2 ON ON OFF
3 ON OFF ON
4 OFF ON ON
Black & Veatch 14 Date 7/7/2011
PARASITIC TESTING RESULTS
June 15, 2011 IIA = 0V/in IIB = 2.0V/in
Point Cable Date Time
RMS
Amps
RMS
Volts MAT 1 MAT 2 MAT 3
PS2 R1 6/15/2011 7:16 AM 0 62 ON ON ON
PS2 R2 6/15/2011 7:16 AM 0 62 ON ON ON
PS2 R3 6/15/2011 7:16 AM 69 62 ON ON ON
PS2 R4 6/15/2011 7:16 AM 67 62 ON ON ON
PS2 R5 6/15/2011 7:16 AM 67 62 ON ON ON
PS2 R6 6/15/2011 7:16 AM 66 62 ON ON ON
PS2 R1 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R2 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R3 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R4 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R5 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R6 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R1 6/15/2011 7:28 AM 0 60 ON OFF ON
PS2 R2 6/15/2011 7:28 AM 0 60 ON OFF ON
PS2 R3 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R4 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R5 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R6 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R1 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R2 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R3 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R4 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R5 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R6 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R1 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R2 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R3 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R4 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R5 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R6 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
Black & Veatch 15 Date 7/7/2011
During the analysis of the parasitics, B&V noticed an abnormality in the data. The data suggested that current was not flowing through the Parasitic 2 cables. During February 2011 the opposite was true. The parasitic switch enclosure was opened to check the integrity of the cables.
Inspection of the switch closure showed there was damage to the switch and that the cables to
Parasitic 2 were missing. It appears that the cables from the parasitic mat were snagged and ripped from the enclosure down through the feeder conduit that connects the cables to the parasitic mat.
The damage may have been caused by a barge anchor or by debris dragging through the canal. B&V documented the findings and participated in a conference call with various Chicago District personnel to discuss the findings. The following pictures document the damage within the enclosure. The exact timing of the damage is unknown. The enclosure was opened and tested during the February 2011 field test. Any testing that required the operation of Parasitic 2 during since the February 2011 field test can not be considered reliable.
Black & Veatch 16 Date 7/7/2011
Busbar Tests
B&V was requested to perform tests on the 2A busbar that provides voltage to the pulsars.
Testing was completed on June 15th, 2011 around 12:00 pm. See the following results and pictures from the test.
BUS TEST AT 2A
June 15, 2011 IIA = 0V/in
IIB = 2.3V/in
BUS Date Time
RMS
Volts
DC
Volts
Pk‐Pk Volts
Peak Max Volts
1 6/15/2011 11:10 AM 45 ‐1.1 231 118
2 6/15/2011 11:10 AM 36 3.6 190 115
3 6/15/2011 11:10 AM 30 1.6 171 98
4 6/15/2011 11:10 AM 27 4.1 161 97
Black & Veatch 17 Date 7/7/2011
PROPER LOCK OUT / TAG OUT
EXPOSED BUSBAR
PERFORMING BUSBAR TEST
REPLACING BUSBAR COVE
Black & Veatch 18 Date 7/7/2011
6. Conclusion
Direct comparisons between the February 2011 and the June 2011 field testing are difficult to make due to the site changes and the climate changes. The June 2011 electrical field mapping confirmed lower reading across the site. The reduction in the readings may be due to the climatic changes, changes in barrier operation (only barrier 2b was operation in June 2011), implementation of electrical mitigation measures throughout the site or changes in the parasitics. There are some locations that showed large electrical potential readings. The locations of high readings are at the new points not previously measured such as the door seals at 2B and grounding at point 21. The field testing performed at the BNSF buildings, MMH, and OXBOW all showed low influence from the barriers and small voltage potentials.
New readings on BNSF and MMH buildings showed influence from the fish barrier. The voltage potentials were small and caused no increase to health and safety. These readings could change with the addition of running barrier 2A on its current system. This would change the analysis of the utility network to include possible heightened voltages at these locations. Effects from a winter climate would speculate that these values would increase with higher ground resistance. These readings were not taken during the February safety trip. Readings at OXBOW were small and inconsistent. OXBOW was disconnect and running on generators. Measurements there indicated no fish barrier influence.
Large differences were not noticed by changing the barrier operation from 2.0 to 2.3 V/in during the safety testing. Points varied across the site in how they increased or decreased and each point behaved uniquely. These changes nonetheless were small enough to not confidently be able to attribute the change directly to a adjusting the barrier operation. There was no attributed heightened safety risk by running at 2.3 V/in. These small changes between the two scenarios were consistent to the data taken in February.
The ground surface voltage potentials are lower when a barge is in the canal. The in canal surface water voltage potentials measured by CERL show a rise in voltage potentials when a barge passes through the fish barrier area. This observation is similar to the observations made during the
February 2011 field testing.
During the field testing, the damage to the Parasitic 2 electrical enclosure was documented.
Black & Veatch 19 Date 7/7/2011
Since Parasitic 2 was not operable the field testing of the impacts associated with the orientation of the parasitics were inconclusive. The parasitics do affect the ground surface voltage potentials.
Increases were shown in some areas while decreases were found elsewhere.
Additional investigation and testing of the parasitics is needed to optimize their operation.
However, Black & Veatch does recommend running Parasitics 1 and 3 in the ON position while barrier 2b is in operation. This setting did show the largest shunting of the current and the most conditioning of the canal electric field.
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY XY
XY
XY
XY XY XYXY
XY
XY
XY XY
XY
XY
XY
XY
XY
XY
XY
XY
XY E Romeo Rd
710602
420419
412411
171168
429A
421.3 421.1421.2
June 2011 Safety Testing Site Overview
Data Sources :
Orthoimage - 2010 NAIP Imagery obtained from USDA Farm Service Agency. 22 June 2011
.XY Stray Current Test Point
Electrical Hazard Area
0 175 350 Feet
MAP
POINT Date Time
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
1 6/13/2011 1423 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
1 6/14/2011 810 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
1 6/14/2011 1514 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
1 6/15/2011 1410 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
1 6/16/2011 756 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
3 6/13/2011 1427 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
3 6/14/2011 812 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
3 6/14/2011 1517 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
3 6/15/2011 1407 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
3 6/16/2011 757 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
7 6/13/2011 1343 2 1 4609 1753 30 30 2.5 2.5 566 114 896 3.01
7 6/14/2011 743 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
7 6/14/2011 1545 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
7 6/15/2011 1336 2 1 4541 2227 15 15 6.5 6.5 658 159 935 N/A
7 6/16/2011 827 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
9 6/13/2011 1350 2 1 N/A N/A 30 30 2.5 2.5 N/A N/A 896 2.8
9 6/14/2011 748 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
9 6/14/2011 1540 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
9 6/15/2011 1341 2 1 4541 2227 15 15 6.5 6.5 658 159 935 N/A
9 6/16/2011 832 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
20 6/13/2011 1022 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
20 6/14/2011 1035 2 1 4091 2133 15 15 6.5 6.5 594 158 872 2.11
20 6/14/2011 1348 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
20 6/15/2011 1530 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
20 6/16/2011 1000 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
21 6/13/2011 1025 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
21 6/13/2011 1025 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
21 6/14/2011 1047 2 1 4091 2133 15 15 6.5 6.5 594 158 872 2.11
21 6/14/2011 1047 2 1 4091 2133 15 15 6.5 6.5 594 158 872 2.11
21 6/14/2011 1048 2 1 4091 2133 15 15 6.5 6.5 594 158 872 2.11
21 6/14/2011 1352 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
21 6/14/2011 1352 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
21 6/14/2011 1354 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
21 6/15/2011 1531 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
21 6/15/2011 1531 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
21 6/15/2011 1534 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
21 6/16/2011 952 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
June 13‐16, 2011
Safety Testing ‐ BARRIER OPERATION
2B
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
21 6/16/2011 1004 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
21 6/16/2011 1004 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
21 6/16/2011 1006 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
24 6/13/2011 1537 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
24 6/14/2011 1014 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
24 6/14/2011 1332 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
24 6/15/2011 1512 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
24 6/16/2011 933 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
32 6/13/2011 1315 2 1 4150 2332 15 15 6.5 6.5 608 202 896 2.14
32 6/14/2011 828 2.3 1 5576 819 30 30 2.5 2.5 824 109 872 3.35
32 6/14/2011 1510 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
32 6/15/2011 1418 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
32 6/16/2011 749 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
36 6/13/2011 1402 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
36 6/14/2011 758 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
36 6/14/2011 1530 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
36 6/15/2011 1352 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
36 6/16/2011 808 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
46 6/13/2011 1409 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
46 6/14/2011 802 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
46 6/14/2011 1535 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
46 6/15/2011 1355 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
46 6/16/2011 812 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
78 6/13/2011 1339 2 1 4101 820 15 15 6.5 635 579 159 896 2.16
78 6/14/2011 740 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
78 6/14/2011 1548 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
78 6/15/2011 1334 2 1 4541 2227 15 15 6.5 6.5 658 159 935 N/A
78 6/16/2011 823 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
91 6/13/2011 1540 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
91 6/14/2011 1027 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
91 6/14/2011 1340 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
91 6/15/2011 1525 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
91 6/16/2011 955 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
112 6/13/2011 1558 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
112 6/14/2011 956 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
112 6/14/2011 1425 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
112 6/15/2011 1602 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
112 6/16/2011 1032 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
123 6/13/2011 1527 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
123 6/14/2011 917 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
123 6/14/2011 1320 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
123 6/15/2011 1500 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
123 6/16/2011 913 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
130 6/13/2011 1500 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
130 6/14/2011 852 2.3 1 5576 819 30 30 2.5 2.5 824 109 872 3.35
130 6/14/2011 1445 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
130 6/15/2011 1436 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
130 6/16/2011 850 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
133 6/13/2011 1505 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
133 6/14/2011 857 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
133 6/14/2011 1449 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
133 6/15/2011 1441 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
133 6/16/2011 855 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
149 6/13/2011 1503 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
149 6/14/2011 855 2.3 1 5576 819 30 30 2.5 2.5 824 109 872 3.35
149 6/14/2011 1447 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
149 6/15/2011 1438 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
149 6/16/2011 853 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
168 6/13/2011 1553 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
168 6/13/2011 1553 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
168 6/14/2011 952 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
168 6/14/2011 952 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
168 6/14/2011 1420 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
168 6/14/2011 1420 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
168 6/15/2011 1558 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
168 6/15/2011 1558 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
168 6/16/2011 1027 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
168 6/16/2011 1027 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
171 6/13/2011 1547 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
171 6/14/2011 948 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
171 6/14/2011 1408 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
171 6/15/2011 1549 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
171 6/16/2011 1024 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
176 6/13/2011 1058 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
176 6/14/2011 947 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
176 6/14/2011 1408 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
176 6/15/2011 1548 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
176 6/16/2011 1023 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
190 6/13/2011 1047 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
190 6/13/2011 1047 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
190 6/14/2011 920 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
190 6/14/2011 1411 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
190 6/15/2011 1550 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
190 6/16/2011 1015 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
202 6/13/2011 1047 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
202 6/14/2011 920 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
202 6/14/2011 1412 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
202 6/16/2011 1017 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
302 6/13/2011 1038 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
305 6/13/2011 1042 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
305 6/14/2011 1357 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
305 6/15/2011 1539 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
305 6/16/2011 1010 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
400 6/13/2011 1431 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
400 6/14/2011 814 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
400 6/14/2011 1520 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
400 6/15/2011 1405 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
400 6/16/2011 800 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
401 6/13/2011 1437 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
401 6/14/2011 823 2.3 1 5576 819 30 30 2.5 2.5 824 109 872 3.35
401 6/14/2011 1558 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
401 6/15/2011 1415 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
401 6/16/2011 835 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
403 6/13/2011 1355 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
403 6/14/2011 750 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
403 6/14/2011 1525 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
403 6/15/2011 1343 2 1 4541 2227 15 15 6.5 6.5 658 159 935 N/A
403 6/16/2011 818 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
404 6/13/2011 1346 2 1 N/A N/A 30 30 2.5 2.5 N/A N/A 896 2.8
404 6/14/2011 745 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
404 6/14/2011 1543 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
404 6/15/2011 1337 2 1 4541 2227 15 15 6.5 6.5 658 159 935 N/A
404 6/16/2011 828 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
405 6/13/2011 1357 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
405 6/14/2011 753 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
405 6/14/2011 1523 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
405 6/15/2011 1345 2 1 4541 2227 15 15 6.5 6.5 658 159 935 N/A
405 6/16/2011 820 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
407 6/13/2011 1032 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
407 6/14/2011 1355 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
407 6/15/2011 1537 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
407 6/16/2011 1010 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
408 6/13/2011 1036 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
411 6/13/2011 1007 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
411 6/13/2011 1011 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
411 6/13/2011 1011 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
411 6/13/2011 1013 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
411 6/13/2011 1013 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
411 6/14/2011 1022 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
411 6/14/2011 1339 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
411 6/15/2011 1522 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
411 6/16/2011 953 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
412 6/13/2011 1557 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
412 6/14/2011 954 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
412 6/14/2011 1422 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
412 6/15/2011 1600 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
412 6/16/2011 1030 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
413 6/13/2011 1017 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
413 6/14/2011 1032 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
413 6/14/2011 1345 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
413 6/15/2011 1527 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
413 6/16/2011 957 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
418 6/13/2011 1510 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
418 6/14/2011 901 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
418 6/14/2011 1453 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
418 6/15/2011 1443 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
418 6/16/2011 858 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
419 6/13/2011 1440 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
419 6/14/2011 825 2.3 1 5576 819 30 30 2.5 2.5 824 109 872 3.35
419 6/14/2011 1512 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
419 6/15/2011 1420 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
419 6/16/2011 752 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
420 6/13/2011 1318 2 1 4169 1946 15 15 6.5 6.5 597 156 896 2.14
420 6/14/2011 819 2.3 1 5576 819 30 30 2.5 2.5 824 109 872 3.35
420 6/14/2011 1556 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
420 6/15/2011 1402 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
420 6/16/2011 803 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
421.1 6/14/2011 945 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
421.1 6/14/2011 1416 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
421.1 6/15/2011 1606 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
421.1 6/15/2011 1606 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
421.1 6/16/2011 1022 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
421.1 6/16/2011 1022 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
421.2 6/13/2011 1052 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
421.2 6/14/2011 925 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
421.2 6/14/2011 1414 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
421.2 6/15/2011 1555 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
421.2 6/16/2011 1019 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
421.3 6/13/2011 1050 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
421.3 6/14/2011 924 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
421.3 6/14/2011 1413 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
421.3 6/15/2011 1554 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
421.3 6/16/2011 1018 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
509 6/14/2011 1030 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
509 6/14/2011 1344 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
509 6/15/2011 1526 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
509 6/16/2011 956 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
510 6/13/2011 1018 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
510 6/14/2011 1033 2 1 4091 2133 15 15 6.5 6.5 594 158 872 2.11
510 6/14/2011 1347 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
510 6/15/2011 1529 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
510 6/16/2011 1002 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
602 6/13/2011 1417 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
602 6/14/2011 805 2.3 1 5556 824 30 30 2.5 2.5 824 109 872 3.21
602 6/14/2011 1533 2 1 4335 1934 15 15 6.5 6.5 634 155 1004 2.1
602 6/15/2011 1357 2.3 1 6074 1992 30 30 2.5 2.5 899 124 935 3.06
602 6/16/2011 815 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
710 6/13/2011 1534 2.3 1 5410 1707 30 30 2.5 2.5 801 103 896 3.08
710 6/14/2011 1010 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
710 6/14/2011 1329 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
710 6/15/2011 1510 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
710 6/16/2011 928 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
713 6/13/2011 927 2.3 1 5351 1691 30 30 2.5 2.5 824 104 896 2.2
713 6/14/2011 920 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
713 6/16/2011 920 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
714 6/13/2011 929 2.3 1 5351 1691 30 30 2.5 2.5 824 104 896 2.2
714 6/14/2011 1018 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
714 6/14/2011 1326 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
714 6/15/2011 1503 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
714 6/16/2011 954 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
715 6/13/2011 930 2.3 1 5351 1691 30 30 2.5 2.5 824 104 896 2.2
715 6/13/2011 1030 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
715 6/14/2011 1405 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
715 6/15/2011 1544 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
716 6/13/2011 935 2.3 1 5351 1691 30 30 2.5 2.5 824 104 896 2.2
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
716 6/14/2011 1025 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
716 6/14/2011 1403 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
716 6/15/2011 1545 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
717 6/13/2011 956 2.3 1 5449 1907 30 30 2.5 2.5 855 141 896 2.2
717 6/14/2011 1019 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
717 6/14/2011 1020 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
717 6/14/2011 1021 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
717 6/14/2011 1337 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
717 6/14/2011 1337 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
717 6/14/2011 1337 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
717 6/15/2011 1520 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
717 6/15/2011 1520 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
717 6/15/2011 1520 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
717 6/16/2011 937 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
717 6/16/2011 937 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
717 6/16/2011 937 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
717 6/16/2011 954 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
717 6/16/2011 954 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
718 6/13/2011 958 2.3 1 5449 1907 30 30 2.5 2.5 855 141 896 2.2
718 6/13/2011 1003 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
718 6/14/2011 1021 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
718 6/14/2011 1023 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
718 6/14/2011 1338 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
718 6/14/2011 1338 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
718 6/15/2011 1523 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
718 6/15/2011 1523 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
719 6/13/2011 1004 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
719 6/13/2011 1005 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
719 6/14/2011 1005 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
719 6/14/2011 1023 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
719 6/14/2011 1023 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
719 6/14/2011 1025 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
719 6/14/2011 1342 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
719 6/14/2011 1342 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
719 6/14/2011 1342 2 1 4414 2013 15 15 6.5 6.5 640 161 872 2.13
719 6/15/2011 1523 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
719 6/15/2011 1523 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
719 6/15/2011 1523 2 1 4921 2198 15 15 6.5 6.5 284 174 935 2.1
719 6/16/2011 1012 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
719 6/16/2011 1014 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
# 6/16/2011 952 2 1 N/A N/A 15 15 6.5 6.5 N/A N/A N/A N/A
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
ESTIMATED*
Volts (V)
2B‐Narrow
ESTIMATED*
Volts (V)
2B‐Wide
ESTIMATED*
Amps (A)
2B ‐Narrow
ESTIMATED*
Amps (A)
2B ‐ Wide
ESTIMATED*
Hertz (Hz)
2B‐Narrow
ESTIMATED*
Hertz (Hz)
2A‐Wide
ESTIMATED*
Pulse Width (ms)
2B‐Narrow
ESTIMATED*
Pulse Width (ms)
2B‐Wide
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐
Narrow
ESTIMATED*
Power Usage (KW)
Barrier 2B ‐ Wide
ESTIMATED
Conductivity (µS)
Measured
In Water
Voltage
(V/in)
429A 6/13/2011 1056 2.3 1 5517 2155 30 30 2.5 2.5 864 169 896 3.52
429A 6/14/2011 926 2.3 1 5517 2074 30 30 2.5 2.5 810 114 872 3.02
429A 6/14/2011 1415 2 1 4430 1874 15 15 6.5 6.5 644 149 872 2.11
429A 6/15/2011 1556 2.3 1 6171 2002 30 30 2.5 2.5 920 123 953 2.92
429A 6/16/2011 1020 2.3 1 6933 2846 30 30 2.5 2.5 1029 174 924 N/A
* Control room data was only recorded when barrier configurations were changed. Because the barrier constantly changes its output to match canal conductivity, actual values for times between these changes are only an estimate and interpretation.
Point Cable Date Time
RMS
Amps
RMS
Volts MAT 1 MAT 2 MAT 3
PS2 R1 6/15/2011 7:16 AM 0 62 ON ON ON
PS2 R2 6/15/2011 7:16 AM 0 62 ON ON ON
PS2 R3 6/15/2011 7:16 AM 69 62 ON ON ON
PS2 R4 6/15/2011 7:16 AM 67 62 ON ON ON
PS2 R5 6/15/2011 7:16 AM 67 62 ON ON ON
PS2 R6 6/15/2011 7:16 AM 66 62 ON ON ON
PS2 R1 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R2 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R3 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R4 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R5 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R6 6/15/2011 7:22 AM 0 3.2 ON ON OFF
PS2 R1 6/15/2011 7:28 AM 0 60 ON OFF ON
PS2 R2 6/15/2011 7:28 AM 0 60 ON OFF ON
PS2 R3 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R4 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R5 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R6 6/15/2011 7:28 AM 75 60 ON OFF ON
PS2 R1 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R2 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R3 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R4 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R5 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R6 6/15/2011 7:34 AM 0 172 OFF ON ON
PS2 R1 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R2 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R3 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R4 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R5 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PS2 R6 6/15/2011 7:40 AM 0 0.5 OFF OFF OFF
PARASITIC TESTING
June 15, 2011 IIA = 0V/in
IIB = 2.0V/in
Step ||
RMS
Step ||
Pk‐Pk
Step ||
DC
Step I
RMS
Step I
Pk‐Pk
Step I
DC
Touch
RMS
TouchPk‐
Pk
Touch
DC
Reach
RMS Reach Pk‐Pk
Reach
DC Parasitic 1 Parasitic 2 Parasitic 3
Barrier IIA
V/in
Barrier IIB
V/in
Measured
In Water
Voltage
(V/in) COLLISION
In‐Water
Field Mapping NOTES:
1 6/13/2011 1423 0.105 0.32 0.077 0.183 1.06 ‐0.078 1.2 6.8 0.32 1.8 10.4 0.5 ON ON ON 0.0 2.3 3.08 YES WIRE AT GATE HAS BEEN REMOVED
1 6/14/2011 810 0.044 0.266 ‐0.103 0.08 0.51 0.2 1.51 8.9 0.112 5.4 30 ‐0.31 OFF ON ON 0.0 2.3 3.21 YES
1 6/14/2011 1514 0.051 0.136 0.002 0.227 0.81 ‐0.142 1.7 8.9 0.3 5.85 27 ‐0.01 OFF ON ON 0.0 2 2.1 YES
1 6/15/2011 1410 0.033 0.319 ‐0.105 0.19 1.45 ‐0.13 0.22 7.5 1.2 3 12 ‐0.4 ON OFF ON 0.0 2.3 3.06 YES
1 6/16/2011 756 0.651 0.338 0.093 0.19 1.11 0.156 1.3 7.6 0.366 1.4 8.5 ‐0.48 ON OFF ON 0.0 2 N/A YES
3 6/13/2011 1427 0.067 0.366 0.033 0.245 1.2 ‐0.154 0.31 0.96 0.27 N/A N/A N/A ON ON ON 0.0 2.3 3.08 YES
3 6/14/2011 812 0.21 1.16 0.032 0.72 3.78 0.22 1.28 7 ‐0.063 N/A N/A N/A OFF ON ON 0.0 2.3 3.21 YES
3 6/14/2011 1517 0.41 1.89 ‐0.223 0.225 1.04 0.005 1.34 6.5 0.033 N/A N/A N/A OFF ON ON 0.0 2 2.1 YES
3 6/15/2011 1407 0.049 0.23 0.057 0.185 0.98 0.017 0.33 1.84 0.089 N/A N/A N/A ON OFF ON 0.0 2.3 3.06 YES
3 6/16/2011 757 0.075 0.35 ‐0.023 0.219 1.3 ‐0.114 0.46 2.3 0.137 N/A N/A N/A ON OFF ON 0.0 2 N/A YES
7 6/13/2011 1343 0.04 1.9 0.015 2.88 20.7 ‐0.19 N/A N/A N/A N/A N/A N/A ON ON ON 0.0 2 3.01 YES
7 6/14/2011 743 0.5 2.24 0.98 7.57 38 ‐0.77 N/A N/A N/A N/A N/A N/A OFF ON ON 0.0 2.3 3.21 YES
7 6/14/2011 1545 0.329 1.41 ‐0.061 6.76 0.385 ‐0.39 N/A N/A N/A N/A N/A N/A OFF ON ON 0.0 2 2.1 YES
7 6/15/2011 1336 0.21 2.6 0.14 2.13 13.6 ‐0.034 N/A N/A N/A N/A N/A N/A ON OFF ON 0.0 2 N/A YES
7 6/16/2011 827 0.097 0.83 0.14 0.65 2.83 0.039 N/A N/A N/A N/A N/A N/A ON OFF ON 0.0 2 N/A YES
9 6/13/2011 1350 0.14 1.2 0.043 0.43 4.5 ‐0.0014 N/A N/A N/A N/A N/A N/A ON ON ON 0.0 2 2.8 YES
9 6/14/2011 748 0.47 2.7 0.11 2.4 12.5 ‐0.14 1.06 5.4 0.56 N/A N/A N/A OFF ON ON 0.0 2.3 3.21 YES
9 6/14/2011 1540 0.51 2.57 0.154 2.35 11.2 ‐0.15 1.97 9.3 0.56 N/A N/A N/A OFF ON ON 0.0 2 2.1 YES
9 6/15/2011 1341 0.203 1.15 0.045 0.719 3.89 0.018 0.778 0.425 0.447 N/A N/A N/A ON OFF ON 0.0 2 N/A YES
9 6/16/2011 832 0.097 0.86 0.035 0.31 0.18 ‐0.21 0.46 3.8 0.51 N/A N/A N/A ON OFF ON 0.0 2 N/A YES
20 6/13/2011 1022 0.135 0.98 ‐0.04 0.8 4.9 ‐0.14 3.35 19 0.21 N/A N/A N/A ON ON ON 0.0 2.3 3.52 YES TOUCH TO FENCE BOLT
20 6/14/2011 1035 0.05 0.768 ‐0.037 0.53 1.68 ‐0.19 1.17 8.4 0.15 N/A N/A N/A ON ON ON 0.0 2 2.11 YES
20 6/14/2011 1348 0.111 0.449 ‐0.043 0.63 6.23 ‐0.12 2.2 11.5 0.23 N/A N/A N/A ON ON ON 0.0 2 2.13 YES
20 6/15/2011 1530 0.1 0.607 ‐0.004 1.2 6.5 ‐0.103 2.75 11.9 ‐0.05 N/A N/A N/A ON OFF ON 0.0 2 2.1 YES
20 6/16/2011 1000 0.051 0.875 ‐0.043 0.252 2.46 0.071 0.23 3.2 0.004 N/A N/A N/A ON OFF ON 0.0 2 N/A YES
21 6/13/2011 1025 2.7 14.4 0.11 0.075 3.3 0.006 6.07 32 0.25 N/A N/A N/A ON ON ON 0.0 2.3 3.52 YES TOUCH TO SUB FENCE
21 6/13/2011 1025 N/A N/A N/A N/A N/A N/A 6.71 37.7 ‐0.95 N/A N/A N/A ON ON ON 0.0 2.3 3.52 YES TOUCH TO GUY WIRE
21 6/13/2011 1030 N/A N/A N/A N/A N/A N/A 42.5 240 0.1 N/A N/A N/A ON ON ON 0.0 2.3 3.52 YES GND ON PWR POLE SOUTH OF SUB
21 6/14/2011 1047 N/A N/A N/A N/A N/A N/A 3.04 17.6 ‐0.9 N/A N/A N/A ON ON ON 0.0 2 2.11 YES TOUCH TO GUY WIRE
21 6/14/2011 1047 2.02 20 ‐0.14 0.35 2.02 0.026 5.08 28 0.38 N/A N/A N/A ON ON ON 0.0 2 2.11 YES TOUCH TO FENCE
21 6/14/2011 1048 N/A N/A N/A N/A N/A N/A 33 194 0.5 N/A N/A N/A ON ON ON 0.0 2 2.11 YES GRND PWR POLE SO. OF SUB
21 6/14/2011 1352 1.1 13.1 ‐0.025 0.153 1.2 ‐0.017 2.41 14.8 0.17 N/A N/A N/A ON ON ON 0.0 2 2.13 YES TOUCH TO FENCE
21 6/14/2011 1352 N/A N/A N/A N/A N/A N/A 5.02 30.7 ‐0.81 N/A N/A N/A ON ON ON 0.0 2 2.13 YES TOUCH TO GUY WIRE
21 6/14/2011 1354 N/A N/A N/A N/A N/A N/A 32.5 211 0.01 N/A N/A N/A ON ON ON 0.0 2 2.13 YES TOUCH TO PWR POLE GROUNDING
21 6/15/2011 1531 5.6 31 0.08 0.234 1.3 0.065 4.65 26 ‐0.03 N/A N/A N/A ON OFF ON 0.0 2.3 2.92 YES TOUCH TO FENCE
21 6/15/2011 1531 N/A N/A N/A N/A N/A N/A 6.34 38 ‐1.2 N/A N/A N/A ON OFF ON 0.0 2.3 2.92 YES TOUCH TO GUY WIRE
21 6/15/2011 1534 N/A N/A N/A N/A N/A N/A 28 215 ‐2.9 N/A N/A N/A ON OFF ON 0.0 2.3 2.92 YES PWR POLE SO. OF SUB
21 6/16/2011 1004 1.2 5.6 ‐0.13 0.49 0.148 0.035 2.42 13.7 1.19 N/A N/A N/A ON OFF ON 0.0 2 N/A YES TOUCH TO FENCE
21 6/16/2011 1004 N/A N/A N/A N/A N/A N/A 5.3 26 0.12 N/A N/A N/A ON OFF ON 0.0 2 N/A YES TOUCH TO GUY WIRE
21 6/16/2011 1006 N/A N/A N/A N/A N/A N/A 33.5 160 4.9 N/A N/A N/A ON OFF ON 0.0 2 N/A YES GRND PWR POLE SOUTH SUB
24 6/13/2011 1537 0.54 3.19 0.001 0.59 2.4 0.12 2.3 81 0.14 N/A N/A N/A ON ON ON 0.0 2.3 3.08 YES
24 6/14/2011 1014 0.73 4.24 0.002 0.5 3.3 0.16 2 80 0.12 N/A N/A N/A ON OFF ON 0.0 2.3 3.02 YES
24 6/14/2011 1332 0.63 3.5 0.42 0.018 0.065 0.08 1.79 0.56 0.17 N/A N/A N/A ON ON ON 0.0 2 2.13 YES
24 6/15/2011 1512 0.47 2.86 ‐0.02 0.223 1.5 0.104 1.5 49.6 0.01 N/A N/A N/A ON OFF ON 0.0 2 2.1 YES
24 6/16/2011 933 0.28 1.9 0.095 0.21 1.6 0.13 1.5 63 0.03 N/A N/A N/A ON OFF ON 0.0 2 N/A YES
32 6/13/2011 1315 N/A N/A N/A N/A N/A N/A 1.8 10 0.92 N/A N/A N/A ON ON ON 0.0 2 2.14 YES
32 6/14/2011 828 N/A N/A N/A N/A N/A N/A 1.5 1.6 0.4 N/A N/A N/A OFF ON ON 0.0 2.3 3.35 YES
32 6/14/2011 1510 N/A N/A N/A N/A N/A N/A 0.7 2.6 ‐0.55 N/A N/A N/A OFF ON ON 0.0 2 2.1 YES
32 6/15/2011 1418 N/A N/A N/A N/A N/A N/A 0.261 2.18 0.341 N/A N/A N/A ON OFF ON 0.0 2.3 3.06 YES
32 6/16/2011 749 N/A N/A N/A N/A N/A N/A 1.78 6.07 0.67 N/A N/A N/A ON OFF ON 0.0 2 N/A YES
36 6/13/2011 1402 1.5 2.4 ‐1.3 0.109 0.126 0.1 0.378 1.15 ‐0.132 N/A N/A N/A ON ON ON 0.0 2.3 3.08 YES
36 6/14/2011 758 1.5 2.4 ‐1.2 0.126 0.158 0.12 0.56 1.6 ‐0.25 N/A N/A N/A OFF ON ON 0.0 2.3 3.21 YES
36 6/14/2011 1530 0.035 2.3 ‐1.2 0.132 0.172 ‐0.117 0.367 0.85 ‐0.11 N/A N/A N/A OFF ON ON 0.0 2 2.1 YES
36 6/15/2011 1352 0.744 2.03 ‐0.897 0.051 0.25 ‐0.144 2.31 7.8 ‐3.17 N/A N/A N/A ON OFF ON 0.0 2.3 3.06 YES
OTHER TESTING
Safety Testing ‐ FIELD DATA
June 13‐16, 2011 STEP TOUCH REACH PARASITICS BARRIER
Step ||
RMS
Step ||
Pk‐Pk
Step ||
DC
Step I
RMS
Step I
Pk‐Pk
Step I
DC
Touch
RMS
TouchPk‐
Pk
Touch
DC
Reach
RMS Reach Pk‐Pk
Reach
DC Parasitic 1 Parasitic 2 Parasitic 3
Barrier IIA
V/in
Barrier IIB
V/in
Measured
In Water
Voltage
(V/in) COLLISION
In‐Water
Field Mapping NOTES:
36 6/16/2011 808 0.77 2.5 ‐1.26 0.069 0.198 0.064 2.3 8.1 ‐3.29 N/A N/A N/A ON OFF ON 0.0 2 N/A YES
46 6/13/2011 1409 0.23 10.2 0.21 0.42 3.5 0.063 4.6 22.2 0.3 N/A N/A N/A ON ON ON 0.0 2.3 3.08 YES
46 6/14/2011 802 3.8 21 0.42 0.6 3.9 ‐0.01 9.7 49.4 0.83 N/A N/A N/A OFF ON ON 0.0 2.3 3.21 YES
46 6/14/2011 1535 3.9 18.4 ‐0.18 0.42 1.04 ‐0.15 10.54 46 0.45 N/A N/A N/A OFF ON ON 0.0 2 2.1 YES
46 6/15/2011 1355 1.78 11.1 0.29…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .