This document provides details for a federal construction solicitation. The Department of Energy is seeking to award a firm fixed-price construction contract valued between $5-10 million to build a viewing platform and general purpose building at the East Tennessee Technology Park in Oak Ridge, Tennessee. The solicitation is set aside for small businesses only. Interested parties must submit bids electronically through the Procurement Integrated Enterprise Environment by 1:00 PM Central Time on January 19, 2023. Upon award, the selected contractor must provide performance and payment bonds each valued at 100% of the contract price. The pre-bid site visit will take place on January 4, 2023 and all registration requirements for attendance must be met.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING NUMBER
DRAWING TITLE
DRAWING SCALE
SHEET NUMBER
A101
SYMBOLS
A101
SIM
A101
1 Ref
R ef
1 Ref
R ef
SIM
A101R101
1 SIM
R101 A101
SECTION
NUMBER
SHEET ON WHICH
SECTION IS SHOWN
DIRECTION OF CUT
DETAIL
NUMBER
CALLOUT
DRAWING
NUMBER
VIEW
NUMBER
SHEET
NUMBER
ROOM
NAME
ROOM
NUMBER
DOOR TAG
WINDOW TAG
SPOT
ELEVATION
TITLE BAR
SECTION
INTERIOR ELEVATION
DETAIL
ELEVATION
KEY NOTE
16a
WALL TAG
Room name
150 SF
ROOM SQUARE
FOOTAGE
W25
SHEET ON WHICH
SECTION IS TAKEN
SHEET ON WHICH
ELEVATION IS
SHOWN
TAGS
MISC.
SHEET ON WHICH
SECTION IS SHOWN
SHEET ON WHICH
SECTION IS TAKEN
1. COORDINATE WITH APPLICABLE DIMENSIONS AND
DETAILS ON OTHER SHEETS.
2 COORDINATE WITH REQUIREMENTS OF UCOR/DOE
SUPPLIED EQUIPMENT AS REQUIRED.
3. DIMENSIONS ARE TO FACE OF STUD OR OUTSIDE
EDGE GIRT U.N.O..
4. THE CONTRACTOR FOR CONSTRUCTION SHALL
LAYOUT ALL PARTITIONS AND VERIFY ACCEPTABILITY OF
LAYOUT WITH ARCHITECT PRIOR TO START OF THIS
WORK.
5. DO NOT SCALE DRAWINGS, IF DIMENSIONS ARE IN
QUESTION, THE CONTRACTOR FOR CONSTRUCTION
SHALL OBTAIN WRITTEN CLARIFICATION FROM
ARCHITECT BEFORE CONTINUING WITH CONSTRUCTION.
6. SEE "SITE IMPROVEMENT DESIGN K-25 PHASE II" FOR
SITE INFORMATION & "EXHIBIT DESIGN K-25 PHASE II"
FOR EXHIBIT INFORMATION.
7. COORDINATE WITH ARCHITECT FOR SPECIFIC
LOCATIONS OF ELECTRICAL FLOOR BOXES
GENERAL NOTES
Telephone:
Fax:
Contact:
E-Mail:
Web Site:
Telephone:
Fax:
Contact:
E-Mail:
Web Site:
Telephone:
Fax:
Contact:
E-Mail:
Web Site:
Telephone:
Fax:
Contact:
E-Mail:
Web Site:
Telephone:
Fax:
Contact:
E-Mail:
Web Site:
Telephone:
Fax:
Contact:
E-Mail:
Web Site:
Telephone:
Fax:
Contact:
E-Mail:
Web Site:
LANDSCAPE
HEDSTROM DESIGN
110 WEST MAGNOLIA AVENUE
KNOXVILLE , TENNESSEE 37917
865.329.0012 865.329.0064 www.hedstromdesign.com
ANDREW SPATZ
andrew@hedstromdesign.com
STRUCTURAL
Ross Bryan ASSOCIATES, INC. ENGINEERS
227 FRENCH LANDING DRIVE
NASHVILLE , TENNESSEE 37228
615.323.1300 615.327.4446 rossbryan.com
KURT BOYD
boyd@rossbryan.com
MP&E ENGINEER
FACILITY SYSTEMS CONSULTANTS
713 S CENTRAL ST #101
KNOXVILLE , TENNESSEE 37902
865.246.0164 865.246.1084 www.facilitysystems.org
LARRY HEADLA
lheadla@facilitysystems.com
CIVIL ENGINEER
FULGHUM MACINDOE & ASSOCIATES, INC.
10330 HARDIN VALLEY ROAD, SUITE 201
KNOXVILLE , TENNESSEE 37932
865.690.6419 865.690.4668 www.fulgrammacindoe.com
AARON GRAY
gray@fulghummacindoe.com
EXHIBIT DESIGNER
HILFERTY & ASSOCIATES, INC.
14240 ROUTE 550
ATHENS , OHIO 45701
740.448.3821
(865) 544-0402 www.hilferty.com
CRAIG DICKELMAN
craig@hilferty.com
ARCHITECTS
SMEE + BUSBY ARCHITECTS, P.C.
2554 SUTHERLAND AVE
KNOXVILLE , TENNESSEE 37919
865.521.7550 865.521.7551 www.smeebusby.com
GREGOR SMEE
gsmee@smeebusby.com
UCOR
PROJECT NAME:
SITE CLASS
TYPE REV
RPE
DATE
DRAWING REVISIONS
SCALE:LE DRAWING NUMBER
BUILDING
ELECTRONIC SIGNATURES
PROFESSIONAL SEAL
TITLE:
CD
U
ORG/
ENGR
ENGR
CHK
PROJ
ENGR
KAREA ETTP
PROJECT RECORD NUMBER:
AS SHOWN
CONFIGURATION MANAGEMENT LEVEL
DE-SC-0004645
an AECOM-led partnership with Jacobs
MANAGED FOR THE DEPARTMENT OF ENERGY
UNDER CONTRACT NUMBER DE-SC-0004645
OAK RIDGE TN 37830
OAK RIDGE RESERVATION
3/31/2022 CFC SUBMITTAL GC GC SB GS
ARCHITECTSSMEE + BUSBY
Knoxville, TN 37902
DRW
BY
GS
QA
SB
A1E-700NHP-
FOUNDATION VENTING ENGINEER
SHIELD ENGINEERING, INC.
4301 TAGGART CREEK ROAD
CHARLOTTE , NORTH CAROLINA 28208
704.394.6913 shieldengineering.com
RAY TANT
rtant@shieldengineering.com
REV. DATE DESCRIPTION
UCOR
OAK RIDGE, TENNESSEE
21026
BUILDING DESIGN K-25 PHASE II
BUILDING COVER SHEET
H684
12" = 1'-0"
VIEW NAME
DRAWING INDEX
ARCHITECTURAL
A1E-700NHP-H685 RENDERING 1
A1E-700NHP-H686 RENDERING 2
A1E-700NHP-H687 RENDERING 3
A1E-700NHP-H688 RENDERING 4
A1E-700NHP-H689 WALL TYPES
A1E-700NHP-H690 LIFE SAFETY PLANS
A1E-700NHP-H691 FLOOR PLANS
A1E-700NHP-H692 REFLECTED CEILING PLANS
A1E-700NHP-H693 ROOF PLAN
A1E-700NHP-H694 ENLARGED PLANS
A1E-700NHP-H695 STAIR DESIGNS
A1E-700NHP-H696 ENTRY CANOPY
A1E-700NHP-H697 EXTERIOR ELEVATIONS
A1E-700NHP-H698 BUILDING SECTION - LONGITUDINAL
A1E-700NHP-H699 BUILDING SECTIONS
A1E-700NHP-H700 BUILDING SECTION - VIEWING PLATFORM
A1E-700NHP-H701 WALL SECTIONS
A1E-700NHP-H702 WALL SECTIONS - SIDE WALLS
A1E-700NHP-H703 WALL SECTIONS - STOREFRONT SYSTEMS
A1E-700NHP-H704 DETAILS - OPENINGS
A1E-700NHP-H705 DETAILS - METAL PANEL
A1E-700NHP-H706 DETAILS - DOORS
A1E-700NHP-H707 DETAILS - CONNECTIONS
A1E-700NHP-H708 DETAILS
A1E-700NHP-H709 DOOR TYPES
A1E-700NHP-H710 WINDOW TYPES
A1E-700NHP-H711 FINISH PLAN & SCHEDULES
STRUCTURAL
S1E-700NHP-H712 GENERAL NOTES
S1E-700NHP-H713 SPECIAL INSPECTIONS
S1E-700NHP-H714 TYPICAL DETAILS - STEEL
S1E-700NHP-H715 TYPICAL DETAILS - FOUNDATION
S1E-700NHP-H716 TYPICAL DETAILS - CONCRETE MASONRY
S1E-700NHP-H717 LEVEL 01 FOUNDATION PLAN
S1E-700NHP-H718 LEVEL 02 FRAMING PLAN
S1E-700NHP-H719 ROOF FRAMING PLAN
S1E-700NHP-H720 SCHEDULES AND DIAGRAMS
S1E-700NHP-H721 BRACED FRAMING AND CMU ELEVATIONS
S1E-700NHP-H722 FOUNDATION SECTIONS
S1E-700NHP-H723 FRAMING SECTIONS
S1E-700NHP-H878 FRAMING CONNECTIONS
S1E-700NHP-H879 MISCELLANEOUS CONNECTIONS
MECHANICAL
M1E-700NHP-H726 HVAC SCHEDULES, NOTES, AND LEGENDS
M1E-700NHP-H727 HVAC DETAILS
M1E-700NHP-H728 FIRST FLOOR HVAC PLAN
M1E-700NHP-H729 SECOND FLOOR HVAC PLAN
M1E-700NHP-H730 ROOF HVAC PLAN
PLUMBING
P1E-700NHP-H731 PLUMBING SCHEDULES, NOTES & DETAILS
P1E-700NHP-H732 SANITARY PLAN
P1E-700NHP-H733 DOMESTIC WATER PLAN
P1E-700NHP-H734 NATURAL GAS PLAN
ELECTRICAL
E1E-700NHP-H735 ELECTRICAL LEGENDS, SCHEDULES & DETAILS
E1E-700NHP-H736 PANELBOARDS & RISER DIAGRAM
E1E-700NHP-H737 LIGHTING PLAN
E1E-700NHP-H738 POWER PLAN
E1E-700NHP-H739 COMMUNICATIONS, FIRE ALARM PLAN & GROUNDING PLAN
E1E-700NHP-H740 HVAC POWER PLAN
E1E-700NHP-H741 ROOF ELECTRICAL PLAN
A1E-700NHP-H684 BUILDING COVER SHEET
FIRE PROTECTION
F1E-700NHP-H724 FIRE PROTECTION SCHEDULES, NOTES & DETAILS
F1E-700NHP-H725 FIRE PROTECTION FLOOR PLANS
CODE SYNOPSIS
Name Gross Area Main Floor 7534 SF Viewing Platform 2077 SF
9611 SF
K-25 VIEWING PLATFORM BUILDING SITE IMPROVEMENTS
Occupancy: A3 Construction Type: IIIB Fully Sprinklered
Required Provided -Height 75' Max 44' -# of Stories 3 Max 2 -Area 28,500 Max 9,369SF
Occupant Load: 1 per 30sf net 196 (Floor 1) (Table 1004.5) 53 (Floor 2) (Exhibits/Museum)
# of Exits per Floor 2 4 (Floor 1) (Table 1006.3.2) 2 (Floor 2)
Interior Stairway -Width (1009.3.2) 48" 48" -Fire Rating (1023.2) 1hr 1hr -Area of Refuge (1009.3.3) Not required per exception 2
Exit Access Stairway (Section 1019.3) Permitted under exception 1 -Width 48" 72"
2018 International Building Code (IBC) 2018 International Fire Code (IFC) 2018 International Plumbing Code (IPC) 2018 International Mechanical Code (IMC) 2018 International Fuel Gas Code (IFGC) 2018 International Energy Code (IECC)
2020 NEC (NFPA 70, NFPA 70E)
2018 NFPA 70E, Arc Flash Protection 2017 American National Standards Institute
2009 ICC A117.1 (ANSI)
2010 ADA Standards for Accessible Design
BUILDING DESIGN
SHEET NUMBER SHEET TITLEREV
VENTING SYSTEM
C1E-700NHP-H849 VENT SYSTEM PLAN
C1E-700NHP-H850 FOUNDATION VENTING SYSTEM DETAILS AND SPECIFICATIONS
1 08/02/2022 CLARIFY EXTENT OF EXISTING UTILITIES TO BE REMOVED
OR ABANDONED IN PLACE GC GC SB SGSG SB
REVISED CFC - REVISION CLOUDS AND TRIANGLES REMOVED TO
PRODUCE A CLEAN DRAWING SET FOR USACE TO START PROCUREMENT2 GC GC SB SGSG SB10/06/2022
CLARIFICATIONS IN RESPONSE TO BIDDER QUESTIONS3 1/20/2023 GC GC SB SGSG SB
MAIN FLOOR
0' - 0"
VIEWING
PLATFORM
24' - 0"
1 4 5 6
PLATFORM
PARAPET
44' - 0"
T.O. GLASS
34' - 0"
SOFFIT
20' - 0"
PARAPET
32' - 0"
'-0
INSULATED METAL PANEL, TYPE 1
H700H691
ROOF LINE BEHIND
PRE-FINISHED METAL
COPING, COLOR TO MATCH
METAL PANEL BELOW
ALUMINUM STOREFRONT SYSTEM
W13
W1
P.E. METAL CANOPY,
SEE DETAILS ON
SHEET 696
INSULATED METAL
PANEL, TYPE 2
ROOF LINE BEHIND
PRE-FINISHED METAL
COPING, COLOR TO MATCH
METAL PANEL BELOW
2" EXPANSION JOINT
SPANDREL GLASS
STEEL COLUMN,
PT-4, SEE STRUCT
7.6
EXTERIOR WALL SCONCE, TYP, SEE ELEC
INSULATED METAL PANEL, TYPE 1A
TY
P
'-0
25'-0" 25'-0" 5'-0"
H703H691
THROUGH WALL FLASHING AT ENTRY
CANOPY, SEE SECTION ON H703
" 12
VERTICAL PANEL
SUPPORT AT 6'-0" O.C. H697
MAIN FLOOR
0' - 0"
VIEWING
PLATFORM
24' - 0"
BCD
PLATFORM
PARAPET
44' - 0"
AE
SOFFIT
20' - 0"
H698H691
PARAPET
32' - 0"
H699H691
W7
W14
W9 W9
HM DOOR & FRAME,
PAINT, TYP.
OVERFLOW SCUPPER, COLOR TO
MATCH INSULATED PANELS, TYP
SCUPPER & DOWNSPOUT,
COLOR TO MATCH
INSULATED PANELS, TYP
OVERFLOW SCUPPER
SCUPPER & DOWNSPOUT
INSULATED METAL
PANEL, TYPE 1A
P.E. METAL CANOPY, SEE
DETAILS ON SHEET H696
PRE-FINISHED METAL COPING,
COLOR TO MATCH INSULATED
METAL PANELS BELOW, TYP
INSULATED METAL
PANEL, TYPE 2
PRE-FINISHED
METAL COPING
STEEL COLUMN, PT-4,
TYP, SEE STRUCT
'-0
ALUMINUM STOREFRONT
EQ EQ EQEQ
ALUMINUM
STOREFRONT
INSULATED METAL
PANEL, TYPE 1A
2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"
2' -0
"2 '-0
"2 '-0
"2 '-0
W10W10W10W10W10
H697 H697
VERTICAL PANEL
SUPPORT AT 6'-0" OC
MAIN FLOOR
0' - 0"
VIEWING
PLATFORM
24' - 0"
PLATFORM
PARAPET
44' - 0"
T.O. GLASS
34' - 0"
SOFFIT
20' - 0"
H700H691
3 2
W2
W13
INSULATED METAL PANEL, TYPE 1
ROOF LINE BEHIND
METAL COPING, COLOR
TO MATCH TYPE 1
ALUMINUM
STOREFRONT
SYSTEM
INSULATED METAL
PANEL, TYPE 2
ROOF LINE BEHIND
PRE-FINISHED METAL
COPING, COLOR TO MATCH
METAL PANEL BELOW
2" EXPANSION JOINT
SPANDREL GLASS
STEEL COLUMN,
PT-4, SEE STRUCT
7.6
GAS METER,
SEE PLUMBING
EXTERIOR
WALL SCONCE,
TYP, SEE ELEC
EMERGENCY
LIGHT, TYP,
SEE ELEC
HM DOOR & FRAME,
PAINT TO MATCH
TYPE 1, TYP.
10'x10' GLASS
OVERHEAD DOOR.
CLEAR ANODIZED
FINISH
INSULATED METAL PANEL, TYPE 1A
ALUMINUM
STOREFRONT SYSTEM
'-0
ALUMINUM STOREFRONT
H702H691
5'-0" 25'-0"
EQ EQ
H703H691
ALUMINUM SCUPPER AND DOWNSPOUT,
COLOR TO MATCH PANEL 2
H697
MAIN FLOOR
0' - 0"
B C D
PLATFORM
PARAPET
44' - 0"
A E
H698H691
PARAPET
32' - 0"
W6
INSULATED METAL PANEL,
TYPE 1
PRE-FINISHED METAL COPING,
COLOR TO MATCH PANEL 1
1'x1' COLLECTOR HEAD, SCUPPER & 4"x4"
DOWNSPOUT, COLOR
TO MATCH PANEL 2
OVERFLOW
SCUPPER
1'x1' COLLECTOR HEAD, SCUPPER & 4"x4"
DOWNSPOUT, COLOR TO
MATCH PANEL 2
OVERFLOW
SCUPPER
ALUMINUM
STOREFRONT
EQEQ EQEQ
EXTERIOR WALL
SCONCE, TYP,
SEE ELEC 12
'-0
SEE ENTRY CANOPY
SHEET H696
CENTER LIGHT FIXTURE
OVER DOOR IN 1'-0" PANEL
INSULATED METAL
PANEL, TYPE 2
EQ EQ
VERTICAL PANEL
SUPPORTS AT
6'-0" O.C., INSULATED METAL PANEL,
TYPE 1A
H697
UCOR
PROJECT NAME:
SITE CLASS
TYPE REV
RPE
DATE
DRAWING REVISIONS
SCALE:LE DRAWING NUMBER
BUILDING
ELECTRONIC SIGNATURES
PROFESSIONAL SEAL
TITLE:
CD
U
ORG/
ENGR
ENGR
CHK
PROJ
ENGR
KAREA ETTP
PROJECT RECORD NUMBER:
AS SHOWN
CONFIGURATION MANAGEMENT LEVEL
DE-SC-0004645
an AECOM-led partnership with Jacobs
MANAGED FOR THE DEPARTMENT OF ENERGY
UNDER CONTRACT NUMBER DE-SC-0004645
OAK RIDGE TN 37830
OAK RIDGE RESERVATION
3/31/2022 CFC SUBMITTAL GC GC SB GS
ARCHITECTSSMEE + BUSBY
Knoxville, TN 37902
DRW
BY
GS
QA
SB
A1E-700NHP-
REV. DATE DESCRIPTION
21026
BUILDING DESIGN K-25 PHASE II
EXTERIOR ELEVATIONS
H697
1/8" = 1'-0"H697 1 East Elevation
1/8" = 1'-0"H697 2 North Elevation
1/8" = 1'-0"H697 3 West Elevation
1/8" = 1'-0"H697 4 South Elevation
ELEVATION NOTES:
1. LOCATE EXTERIOR LIGHTS AS CLOSE TO NOTED
DIMENSIONS AS IS FEASIBLE WITHOUT LOCATING
THEM ON A INSULATED METAL PANEL SEAM.
METAL PANEL LEGEND:
1 - POLAR WHITE
1A - SLATE GREY
2 - TUNDRA
1/20/2023 CLARIFICATIONS IN RESPONSE TO BIDDER QUESTIONS1
1 1/20/2023 CLARIFICATIONS IN RESPONSE TO BIDDER QUESTIONS
SEE SCHED
SE
E
SC
H
ED
F
SEE SCHED
SE
E
SC
H
ED
FG
SEE SCHED
SE
E
SC
H
ED
OH
T
1 2
SE
E
SC
H
ED
2"
2"
SCHED
SEE 2"
2"
SE
E
SC
H
ED
2"
SCHED
SEE 2"
SE
E
SC
H
ED
4"
2"
SCHED
SEE 2"
UCOR
PROJECT NAME:
SITE CLASS
TYPE REV
RPE
DATE
DRAWING REVISIONS
SCALE:LE DRAWING NUMBER
BUILDING
ELECTRONIC SIGNATURES
PROFESSIONAL SEAL
TITLE:
CD
U
ORG/
ENGR
ENGR
CHK
PROJ
ENGR
KAREA ETTP
PROJECT RECORD NUMBER:
AS SHOWN
CONFIGURATION MANAGEMENT LEVEL
DE-SC-0004645
an AECOM-led partnership with Jacobs
MANAGED FOR THE DEPARTMENT OF ENERGY
UNDER CONTRACT NUMBER DE-SC-0004645
OAK RIDGE TN 37830
OAK RIDGE RESERVATION
3/31/2022 CFC SUBMITTAL GC GC SB GS
ARCHITECTSSMEE + BUSBY
Knoxville, TN 37902
DRW
BY
GS
QA
SB
A1E-700NHP-
REV. DATE DESCRIPTION
21026
BUILDING DESIGN K-25 PHASE II
DOOR TYPES
H709
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
ABBREVIATIONS:
AL - ALUMINUM
AL GL - ALUMINUM & GLASS
F - FLUSH
FGL - FIBERGLASS
FG - FULL GLASS
HG - HALF GLASS
HM - HOLLOW METAL
N - NARROW LITE
OH - OVERHEAD DOOR
PT - PAINT
SC WD - SOLID CORE WOOD
STL - STEEL
STN - STAIN
T - TEMPERED GLASS
WD ST GL - WOOD STILE & GLASS
DOOR SCHEDULE
MARK
(DOOR
NUMBER)
DOOR FRAME DETAILS
FIRE
RATING
HARDWARE.
SET COMMENTSHEIGHT THICKNESS TYPE MATERIAL FINISH WIDTH FRAME MATERIAL FINISH HEAD JAMB SILL
101A 7' - 0" 0' - 1 3/4" FG AL GL CLR
ANOD
6' - 0" 2 AL CLR ANOD 5|H704 6|H704 - - 1
101B 7' - 0" 0' - 1 3/4" FG AL GL CLR
ANOD
6' - 0" 2 AL CLR ANOD 14|H706 6|H706 - - 2
102A 7' - 0" 0' - 1 3/4" FG AL GL CLR
ANOD
6' - 0" 2 AL CLR ANOD 5|H704 6|H704 - - 1
102B 7' - 0" 0' - 1 3/4" FG AL GL CLR
ANOD
6' - 0" 2 AL CLR ANOD 14|H706 6|H706 - - 2
103A 7' - 0" 0' - 1 3/4" FG AL GL CLR
ANOD
6' - 0" 2 AL CLR ANOD 5|H704 6|H704 - - 1
104A 7' - 0" 0' - 1 3/4" FG AL GL CLR
ANOD
6' - 0" 2 AL CLR ANOD 1|H704 12|H704 - - 1
105A 7' - 0" 0' - 1 3/4" F SC WD STN 3' - 0" 1 HM PT 9|H706 10|H706 - 1 6
106A 7' - 0" 0' - 1 3/4" FG AL GL CLR
ANOD
3' - 0" 1 AL CLR ANOD 14|H706 6|H706 - - 3
107A 7' - 0" 0' - 1 3/4" F SC WD STN 3' - 0" 1 HM PT 7|H704 8|H704 - - 9
108A 7' - 0" 0' - 1 3/4" F SC WD STN 3' - 0" 1 HM PT 7|H704 8|H704 - - 9
109A 7' - 0" 0' - 1 3/4" F SC WD STN 3' - 0" 1 HM PT 7|H704 8|H704 - - 10
110A 7' - 0" 0' - 1 3/4" F HM PT 3' - 0" 1 HM PT 1|H706 2|H706 3|H706 - 4
111A 7' - 0" 0' - 1 3/4" FG WD ST GL STN 3' - 0" 1 HM PT 7|H704 8|H704 - - 11 1
112A 7' - 0" 0' - 1 3/4" F SC WD STN 3' - 0" 1 HM PT 7|H704 8|H704 - - 12
113A 7' - 0" 0' - 1 3/4" FG WD ST GL STN 3' - 0" 1 HM PT 7|H704 8|H704 - - 11 1
201A 7' - 0" 0' - 1 3/4" F HM PT 3' - 0" 1 HM PT 7|H704 8|H704 - - 9
S101A 7' - 0" 0' - 1 3/4" F HM PT 3' - 0" 3 HM PT 4|H706 5|H706 - 1 5
S201A 7' - 0" 0' - 1 3/4" F HM PT 3' - 0" 3 HM PT 9|H706 10|H706 - - 7
S201B 7' - 0" 0' - 1 3/4" F HM PT 3' - 0" 3 HM PT 4|H706 5|H706 & 9|H707 8|H707 1 8
Z101 10' - 0" 0' - 1 3/4" OH AL GL CLR
ANOD
10' - 0" AL CLR ANOD 11|H706 12|H706 13|H706 -
COMMENTS:
1. GLASS TO BE FROSTED.
1/20/2023 CLARIFICATIONS IN RESPONSE TO BIDDER QUESTIONS1
1 11
B C DA E
EXHIBIT AREA
MONUMENTAL
STAIR
S102
ELEV MACHINE
ROOM
ELEVATOR
STAIR
S101
VESTIBULE
OFFICE
ELEC ROOM
EQUIPMENT
ROOM
STORAGE
SPRINKLER
RISER ROOM
WOMEN'S
RESTROOM
JANITOR'S
CLOSET
MEN'S
RESTROOM
VESTIBULE
GB-1/PT-1 ALL (4)
SIDES OF WALL
LEVEL 5 FINISH FOR
GYPSUM BOARD
8 8
H703H691
B C D
7.67.6
VIEWING
PLATFORM
STAIR
S201
ELEVATOR
MECHANICAL
SC - SEALED CONCRETE
CPT - 1 - CARPET TILE 1
CPT - 2 - CARPET TILE 2
FLOOR FINISH LEGEND
UCOR
PROJECT NAME:
SITE CLASS
TYPE REV
RPE
DATE
DRAWING REVISIONS
SCALE:LE DRAWING NUMBER
BUILDING
ELECTRONIC SIGNATURES
PROFESSIONAL SEAL
TITLE:
CD
U
ORG/
ENGR
ENGR
CHK
PROJ
ENGR
KAREA ETTP
PROJECT RECORD NUMBER:
AS SHOWN
CONFIGURATION MANAGEMENT LEVEL
DE-SC-0004645
an AECOM-led partnership with Jacobs
MANAGED FOR THE DEPARTMENT OF ENERGY
UNDER CONTRACT NUMBER DE-SC-0004645
OAK RIDGE TN 37830
OAK RIDGE RESERVATION
3/31/2022 CFC SUBMITTAL GC GC SB GS
ARCHITECTSSMEE + BUSBY
Knoxville, TN 37902
DRW
BY
GS
QA
SB
A1E-700NHP-
REV. DATE DESCRIPTION
21026
BUILDING DESIGN K-25 PHASE II
FINISH PLAN & SCHEDULES
H711
NOTES:
1. NOT USED.
2. VESTIBULE WALKOFF CARPET = CPT
3. ALL WALLS BEHIND SINKS, TOILETS, AND WATER
FOUNTAINS TO RECEIVE MOISTURE RESISTANT GYP
WITH EPOXY PAINT.
4. PAINT HANDRAILS, GUARDRAILS, & STAIRS, PT 4
5. TILE TO GO UP TO CEILING
6. PAINT CEILING, WALLS, EXPOSED DUCTS, AND
CONDUIT ABOVE 10'-6", PT-2.
7. LOCATION OF MURAL, SEE EXHIBIT DESIGN
8. STAINLESS STEEL CORNER TRIM. 48" TALL
9. INTERIOR FACE OF INSULATED PANELS TO HAVE
BLACK, FACTORY APPLIED FINISH. TOUCH UP IN
FIELD AS NECESSARY
ABBREVIATIONS:
CMU CONCRETE MASONRY UNIT
CPT CARPET TILE
EXP EXPOSED STRUCTURE
EP PT EPOXY PAINT
PLY PRESSURE TREATED PLYWOOD PANELS
GB GYPSUM BOARD
PBT PORCELAIN BASE TILE
PT PAINT
PWT PORCELAIN WALL TILE
RB RUBBER BASE
SC SEALED CONCRETE
FINISH SCHEDULE
ROOM INFORMATION
FLOOR WALL BASE
WALL FINISHES
CEILING
MATERIAL
CEILING
FINISH CEILING HEIGHT NOTESNUMBER NAME
NORTH: MATERIAL /
FINISH
SOUTH: MATERIAL /
FINISH
EAST: MATERIAL
/ FINISH
WEST: MATERIAL
/ FINISH
101 VESTIBULE CPT-2 RB 2 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 PT-2 9' - 11" 2 102 VESTIBULE CPT-2 RB 2 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 PT-2 9' - 11" 2 103 EXHIBIT AREA SC RB 2 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 - - 25' - 6" 3, 4, 6, 9
105 ELEV MACHINE ROOM SC - CMU CMU CMU CMU - - 23' - 6"
"11 - '92-TP1-BG1-TP | 1-BG1-TP | 1-BG1-TP | 1-BG1-TP | 1-BG1 BRCSECIFFO601
107 ELEC ROOM SC RB 1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 PT-1 9' - 11" 108 EQUIPMENT ROOM SC RB 1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 PT-1 9' - 11"
BG1-TP | 1-BG1-TP | 1-BG1 BRCSEGAROTS901 -1 | PT-1 GB-1 | PT-1 GB-1 PT-1 9' - 11" 110 SPRINKLER RISER ROOM SC RB 1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 PT-1 9' - 11" 111 WOMEN'S RESTROOM SC PBT GB-2 | PWT GB-2 | PWT GB-2 | PWT GB-2 | PWT GB-2 PT-2 9' - 11" 3, 5 112 JANITOR'S CLOSET SC RB 1 GB-2 | PT-1 GB-2 | PT-1 GB-2 | PT-1 GB-2 | PT-1 GB-2 PT-1 9' - 11" 3 113 MEN'S RESTROOM SC PBT GB-2 | PWT GB-2 | PWT GB-2 | PWT GB-2 | PWT GB-2 PT-2 9' - 11" 3, 5
114 ELEVATOR CONC - CMU CMU CMU CMU - - 40' - 7"
201 VIEWING PLATFORM CPT-1 RB 1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 GB-1 | PT-1 - - 17' - 11" 4, 6
202 MECHANICAL SC - GB-1 | PT-1 GB-1 | PT-1 CMU GB-1 | PT-1 - - 16' - 8"
4"9 - '32--1-TP | UMC1-TP | UMC1-TP | UMC1-TP | UMC-CSRIATS101S
S102 MONUMENTAL STAIR SC RB 2 GB-1 | PT-1 - CMU | PT-1 GB-1 - - 32' - 11" 4, 7
4"01 - '61--1-TP | UMC1-TP | UMC1-TP | UMC1-TP | UMC-CSRIATS102S
FINISH LEGEND
KEY NAME MATERIAL SPECIFICATION
FLOOR FINISHES
CPT 1 CARPET TILE MOHAWK-BIGELOW, CARPET TILE: ICONIC EARTH-DRIFTED GROUND BT389; COLOR:983; COLORSTRAND SD NYLON; INSTALLATION: BRICK ASHLAR CPT 2 WALK-OFF CARPET SHAW CONTRACT, COLLECTION: STEPPIN OUT, STYLE: #5T032 BON JOUR II, COLOR: #31500 EBONY, 24"X24", INSTALLED QUARTER TURN
SC SEALED CONCRETE SEALED CONCRETE, REFER TO SPEC
BASE/TRIM FINISHES
PBT PORCELAIN BASE TILE CROSSVILLE TILE, COLLECTION: SHADES, COLOR: #AV243 FOG, UNPOLISHED, 6"X24", INSTALLED W/ GT 1 RB 1 RUBBER BASE JOHNSONITE, COLORMATCH TRADITIONAL WALL BASE, COLOR: 40 BLACK B, SIZE: 4" RB 2 RUBBER BASE JOHNSONITE, COLORMATCH TRADITIONAL WALL BASE, COLOR: 40 BLACK B, SIZE: 6"
WALL FINISHES
:ROLOC ,SMAILLIW NIWREHSTNIAP1 TP #SW7636 ORIGAMI WHITE, EGGSHELL FINISH (ALL WALLS)(GB CEILINGS) 0996WS# :ROLOC ,SMAILLIW NIWREHSTNIAP2 TP CAVIAR, FLAT FINISH (PUBLIC GB CEILINGS)
MAGIRO 6367WS# :ROLOC ,SMAILLIW NIWREHSTNIAP3 TP I WHITE, SEMI-GLOSS FINISH (MTL DOOR FRAMES)
)SLIAR( SSOLG IMES ,EZNORB GNIRUDNE 5507WS# :ROLOC ,SMAILLIW-NIWREHSTNIAP4 TP
996WS# :ROLOC ,SMAILLIW NIWREHSTNIAP5 TP 0 CAVIAR, SEMI-GLOSS FINISH (COLUMNS)
PWT 1 PORCELAIN WALL TILE CROSSVILLE, PORCELAIN STONE, ALTERED STATE, COLOR: AV341 WHITE HOT, SIZE: 6"x24", GROUT SIZE: 1/8", EPOXY GROUT: LATICRETE COLOR: 90 LIGHT PEWTER
CEILING FINISHES
GB 1 GYPSUM BOARD
GB 2 GYPSUM BOARD MOISTURE RESISTANT
ERUTCURTS OT NEPO GNILIECNEPONEPO
N
Project North
1/8" = 1'-0"H711 1 Main Floor Plan
N
Project North
1/8" = 1'-0"H711 2 Viewing Platform Plan
ROOM SIGNAGE SCHEDULE
TNETNOC EGANGISSNOITACIFICEPS MOOR
ROOM
NUMBER ROOM NAME SIGNAGE ROOM NAME
SIGNAGE
NUMBER SIGNAGE NOTES
105 ELEV MACHINE ROOM ELEVATOR MACHINE ROOM 109
101ECIFFOECIFFO601
107 ELEC ROOM ELECTRICAL ROOM 102
108 EQUIPMENT ROOM EQUIPMENT ROOM 103
401EGAROTSEGAROTS901
110 SPRINKLER RISER ROOM SPRINKLER RISER ROOM 105
111 WOMEN'S RESTROOM WOMEN'S RESTROOM 106 HANDICAP SYMBOL
112 JANITOR'S CLOSET JANITOR'S CLOSET 110
113 MEN'S RESTROOM MEN'S RESTROOM 107 HANDICAP SYMBOL
3801ROTAVELEROTAVELE411
202 MECHANICAL MECHANICAL 201
202RIATSRIATS102S
GENERAL SIGNAGE NOTES:
1. VERIFY SIGNAGE NAMES, NUMBERS, AND QUANTITIES WITH CONTRACTOR FOR
CONSTRUCTION PRIOR TO FABRICATION.
2. ALL SIGNAGE TO INCORPORATE TACTILE CHARACTERS UNLESS OTHERWISE NOTED.
3. SIGN FOR EACH DOOR
4. SIGNS TO BE MOUNTED 48" AFF TO BOTTOM OF SIGN. PLACE ON LATCH SIDE OF DOOR.
1 GC GC SB SGSG SB
REVISED CFC - REVISION CLOUDS AND TRIANGLES REMOVED TO
PRODUCE A CLEAN DRAWING SET FOR USACE TO START PROCUREMENT10/06/2022
2 1/20/2023 CLARIFICATIONS IN RESPONSE TO BIDDER QUESTIONS
STRUCTURAL DESIGN CRITERIA
1. ALL CONSTRUCTION SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE.
2. SERVICE DESIGN LIVE LOADS ARE AS FOLLOWS:
• ASSEMBLY AREAS: 100 PSF
• MECHANICAL ROOMS: 150 PSF
• STORAGE: 125 PSF
• OFFICE: 50 PSF
• ROOF: 20 PSF
• STAIRS: 100 PSF
• HANDRAILS: 200 LB APPLIED AT ANY POINT IN ANY DIRECTION
• GUARDRAILS:
• 200 LB APPLIED AT ANY POINT IN ANY DIRECTION AT THE TOP OF THE
GUARDRAIL.
• 50 PLF HORIZONTALLY AT THE REQUIRED HEIGHT SIMULTANEOUS WITH 100
PLF VERTICAL LOAD.
• 200 LB HORIZONTAL LOAD ON 1 FT SQ AT ANY LOCATION.
• GRAB BARS: 250 LB APPLIED IN ANY DIRECTION ANYWHERE ALONG THE LENGTH OF
THE BAR.
3. SNOW LOADS ARE AS FOLLOWS:
• GROUND SNOW LOAD: PG - 10 PSF
• FLAT ROOF SNOW LOAD: PF - 10 PSF
• SNOW EXPOSURE FACTOR: CE - 0.9
• IMPORTANCE FACTOR: IS - 1.0
• THERMAL FACTOR: CT -1.1
4. WIND DESIGN DATA
• BASIC WIND SPEED: 104 MPH
• IMPORTANCE FACTOR, IW : 1.0
• EXPOSURE CATEGORY: B
• INTERNAL PRESSURE COEFFICIENT, GCPI : +0.18
• COMPONENTS AND CLADDING DESIGN WIND PRESSURE: SEE TABLE ON SHEET H712.
5. SEISMIC DESIGN DATA
A.
a. SEISMIC IMPORTANCE FACTOR, IE : 1.0
b. RISK CATEGORY: II
B.
a. MAXIMUM SEISMIC SPECTRAL ACCELERATION AT 0.2 SECONDS, SS: 0.5
b. MAXIMUM SEISMIC SPECTRAL ACCELERATION AT 1.0 SECONDS, S1: 0.122
C. SITE CLASS: D
a. DESIGN SPECTRAL RESPONSE ACCELERATION FACTOR AT SHORT PERIOD, SDS: 0.466
b. DESIGN SPECTRAL RESPONSE ACCELERATION FACTOR AT 1-SECOND PERIOD, SD1 : 0.192
D. SEISMIC DESIGN CATEGORY: C
E. SEISMIC RESISTING SYSTEM: STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC
RESISTANCE & INTERMEDIATE REINFORCED MASONRY SHEAR WALL
F. DESIGN BASE SHEAR, V: 96.5 K
G. SEISMIC RESPONSE COEFFICIENT, CS: 0.156
H. RESPONSE MODIFICATION FACTOR, R: 3.0
I. ANALYSIS BY: EQUIVALENT LATERAL FORCE PROCEDURE
GENERAL
1. ALL CONTRACTORS SHALL CONFORM TO THE SAFETY REQUIREMENTS OF THE GOVERNMENT,
AIA DOCUMENT A201, OSHA SAFETY AND HEALTH STANDARDS, AND ANY OTHER LOCAL
AUTHORITY IN CONNECTION WITH THE PROJECT.
2. THE CONTRACTOR SHALL PROVIDE ADEQUATE BRACING AND OTHERWISE PROTECT ALL WORK
IN PROGRESS UNTIL CONSTRUCTION IS COMPLETED.
3. THE CONTRACTOR IS RESPONSIBLE FOR SHORING AND THE STRUCTURAL INTEGRITY OF ANY
EXISTING STRUCTURES DURING CONSTRUCTION.
4. FOR LOCATION OF MISCELLANEOUS ITEMS (SUCH AS OPENINGS, INSERTS, ETC.) AFFECTING
STRUCTURAL WORK, SEE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. ALL
OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
SPECIAL STRUCTURAL DESIGN CRITERIA
SOIL LATERAL DESIGN DATA:
• ACTIVE PRESSURE: 35 PCF
• AT-REST PRESSURE: 55 PCF
FOUNDATION
1. REFER TO S&ME GEOTECHNICAL REPORT (PROJECT NO. 7143-15-062) DATED 10/01/2015 FOR
DETAILED SUBSURFACE INFORMATION.
2. FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2500 PSF. FOOTING
EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE GEOTECHNICAL ENGINEER.
3. THE BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE 18" MINIMUM BELOW FINISHED GRADE UNLESS
NOTED OTHERWISE. CONTRACTOR SHALL CONTROL SURFACE AND SUBSURFACE WATER DURING
CONSTRUCTION SO THAT THE FOUNDATION WILL BE CONSTRUCTED ON DRY SOIL/ROCK. NO
FOUNDATION SHALL BE PLACED IN WATER OR FROZEN SUBSURFACE.
4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN 1 VERTICAL TO 2
HORIZONTAL, EXCEPT AS SHOWN ON THE CONTRACT DOCUMENTS.
5. WHERE COMPACTED EARTH FILL IS SHOWN ON THE CONTRACT DOCUMENTS, IT SHALL BE PLACED IN
STRICT ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER'S REPORT.
6. ELEVATIONS SHOWN THUS,TOF ARE APPROXIMATE TOPS OF FOOTING ELEVATIONS.
(FOOTING BEARING CONDITIONS SHALL BE VERIFIED BY THE GEOTECHNICAL ENGINEER.)
7. ELEVATION OF TOP OF FOOTING MUST BE MAINTAINED AT COLUMNS WHERE NO TOP OF PIER
ELEVATION IS GIVEN. IF FOOTING MUST BE LOWERED, ADD PIER TO ACHIEVE DESIRED ELEVATION.
REINFORCED CONCRETE
1. ALL CONCRETE WORK SHALL CONFORM TO ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI 315 “MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES”, AND CRSI
“MANUAL OF STANDARD PRACTICE” LATEST EDITION.
2. SEE TABLE OF CONCRETE MIX DESIGN REQUIREMENTS ON THIS SHEET FOR THE 28-DAY STRENGTH OF
CAST-IN-PLACE CONCRETE.
3. CONCRETE SHALL HAVE A MAXIMUM WATER-CEMENT RATIO OF 0.45. CONCRETE MIX DESIGNS SHALL BE SUBMITTED
AND APPROVED PRIOR TO CASTING OF ANY CONCRETE.
4. WHERE SHOWN ON CONTRACT DOCUMENTS, LEAN CONCRETE SHALL HAVE A MINIMUM 28-DAY STRENGTH OF 2500
PSI.
5. ALL CONCRETE PLACED SHALL BE CONSOLIDATED BY MECHANICAL VIBRATORS.
6. REINFORCING BARS SHALL CONFORM TO ASTM-A615, "STANDARD SPECIFICATION FOR DEFORMED AND PLAIN
BILLET-STEEL BARS FOR CONCRETE REINFORCEMENT". THE MINIMUM YIELD STRESS OF REINFORCING BARS SHALL
BE 60,000 PSI.
7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM-A185, "STANDARD SPECIFICATION FOR STEEL WELDED WIRE
FABRIC, PLAIN, FOR CONCRETE REINFORCEMENT". MIN. YIELD STRESS 65 KSI FOR WWF.
8. COMPLETE FABRICATION AND PLACING DRAWINGS FOR REINFORCING STEEL SHALL BE SUBMITTED FOR APPROVAL.
NO FABRICATION MAY BEGIN UNTIL DRAWINGS ARE COMPLETED AND APPROVED.
9. LAP SPLICES FOR REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI 318. SPLICES NOT SPECIFICALLY SHOWN
SHALL BE CLASS B SPLICES UNLESS APPROVED BY THE STRUCTURAL ENGINEER.
10. REINFORCING OF ALL CONCRETE MEMBERS SHALL HAVE THE FOLLOWING CLEAR CONCRETE COVER:
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
a. #6 THROUGH #18 BARS: 2"
b. #5 BAR, W31 OR D31 WIRE, AND SMALLER: 1-1/2"
C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
a. SLABS, WALLS, JOISTS:
• #14 AND #18: 1-1/2"
• #11 BAR AND SMALLER: 3/4"
b. BEAMS, COLUMNS:
• PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS: 1-1/2"
c. SHELLS, FOLDED PLATE MEMBERS: 1-1/2"
• #6 BAR AND LARGER: 3/4"
• #5 BAR, W31 OR D31 WIRE, AND SMALLER: 1/2"
11. THE CONTRACTOR SHALL PROVIDE CHAIRS AT 4'-0" CENTER-TO-CENTER TO SUPPORT WIRE MESH WHILE CASTING
SLAB. PULL FABRIC UP BETWEEN SUPPORTS TO PROVIDE 2" CLEARANCE TO TOP OF SLAB. MINIMUM SIDE AND END
LAP ON FABRIC SHALL BE ONE WIRE SPACE.
12. ANCHOR BOLTS SHALL BE F1554 GR. 36 WITH HIGH STRENGTH NUTS UNLESS NOTED OTHERWISE.
13. WELDING OF REINFORCING STEEL SHALL BE DONE IN STRICT ACCORDANCE WITH THE AMERICAN WELDING
SOCIETY "STRUCTURAL WELDING CODE – REINFORCING STEEL", A.W.S. D1.4. PREHEATING OF REINFORCING SHALL
BE BASED ON THE CARBON EQUIVALENT DETERMINED FROM REINFORCING MILL REPORTS. GRADE 60 REINFORCING
SHALL BE WELDED WITH E90XX LOW-HYDROGEN ELECTRODES.
14. CONCRETE WALLS AND SLABS SHALL BE REINFORCED AROUND ALL OPENINGS WITH 2 - #6 BARS ALL SIDES AND
EXTENDED 3'-1" BEYOND OPENING UNLESS NOTED OTHERWISE.
15. THE LONGITUDINAL REINFORCING STEEL IN BOND BEAMS, WALLS, AND FOOTINGS SHALL BE CONTINUOUS AROUND
CORNERS. SEE TYPICAL DETAILS, SHEET H715.
16. A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF COLUMNS AND BEAMS.
17. INTERIOR SLABS-ON-GRADE SHALL BE 4" THICK ON A 4" GRAVEL FILL AND REINFORCED WITH WWF 6 X 6 - W1.4 X
W1.4 UNLESS NOTED OTHERWISE. CONSTRUCTION JOINTS SHALL BE 15'-0" ON CENTER MAXIMUM.
18. SAWN JOINTS IN SLABS-ON-GRADE SHALL BE ACCOMPLISHED WITHIN 24 HOURS OF SLAB PLACEMENT.
19. CASTS OF SLABS-ON-GRADE SHALL HAVE NO LENGTH-TO-WIDTH RATIOS EXCEEDING 2. ADJACENT CASTS SHALL
BE DELAYED A MINIMUM OF THREE DAYS.
20. USE EXPANSION JOINT MATERIAL BETWEEN ALL EXTERIOR SLABS-ON-GRADE AND THE ABUTTING STRUCTURE
EXCEPT AT RETAINING WALLS AND FOUNDATION WALLS.
21. CONSTRUCTION JOINTS IN BEAMS, GIRDERS AND SLABS (WHERE USED) SHALL OCCUR AT MIDSPAN AND SHALL BE
KEYED. IN ALL CASES, THE LOCATION OF CONSTRUCTION JOINTS SHALL BE APPROVED BY THE STRUCTURAL
ENGINEER. KEYWAYS SHALL BE ONE-THIRD THE DEPTH OF THE MEMBER AND PLACED AT MID-DEPTH.
22. CONSTRUCTION AND/OR CONTRACTION JOINTS IN ALL FOUNDATION AND RETAINING WALLS SHALL BE PLACED NOT
MORE THAN 20' - 0" APART AND SHALL BE 3/4" V-CHAMFERED ON BOTH SIDES, UNLESS NOTED. CONSTRUCTION
JOINTS SHALL FALL AT CONTRACTION JOINTS AND SHALL BE KEYED. DISCONTINUE WALL REINFORCING AT
CONTRACTION JOINTS. USE #4 x 4' - 0" DOWELS SPACED AT 12". EXPANSION JOINTS SHALL BE AT 80' - 0". SEE DETAIL, SHEET H715.
23. SHORES SHALL REMAIN IN PLACE OR SLABS AND BEAMS SHALL BE CONTINUOUSLY RESHORED AFTER REMOVAL OF
FORMS UNTIL CONCRETE STRENGTH REACHES 70% OF THE SPECIFIED 28-DAY STRENGTH. ALL CASTS MUST BE
SUPPORTED BY A MINIMUM OF TWO COMPLETED FLOORS.
24. NO BACKFILLING AGAINST BASEMENT AND RETAINING WALLS SHALL BE PERFORMED UNTIL THE CONCRETE IN THE
WALL AND SUPPORTING FLOORS HAS REACHED 100% OF THE DESIGN STRENGTH.
STRUCTURAL STEEL
1. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE 15TH EDITION OF THE "STEEL CONSTRUCTION MANUAL"
OF THE A.I.S.C. WITH THE FOLLOWING EXCEPTIONS: DELETE SECTION 3.2 OF CODE OF STANDARD PRACTICES FOR
STEEL BUILDINGS AND BRIDGES AND INSERT THE FOLLOWING: "ARCHITECTURAL, ELECTRICAL AND/OR
MECHANICAL DESIGN DRAWINGS SHALL BE USED TO SUPPLEMENT THE STRUCTURAL DESIGN DRAWINGS FOR
THE PURPOSES OF DEFINING DETAIL CONFIGURATIONS, ADDITIONAL STRUCTURAL FRAMING NOT SHOWN ON
THE STRUCTURAL DRAWINGS, AND OTHER INFORMATION REQUIRED".
2. ALL REACTIONS AND LOADS SHOWN ON THESE DRAWINGS ARE FACTORED.
3. FABRICATORS SHALL MAINTAIN CERTIFICATION FOR CATEGORY STANDARD BY THE A.I.S.C. QUALITY
CERTIFICATION PROGRAM. ERECTORS SHALL MAINTAIN CERTIFICATION FOR CATEGORY CSE BY THE A.I.S.C.
CERTIFICATION PROGRAM.
4. SHOP DRAWINGS FOR ALL STRUCTURAL STEEL SHALL BE SUBMITTED AND APPROVED PRIOR TO ANY
FABRICATION. REPRODUCTION OF CONTRACT DRAWINGS IS NOT PERMITTED.
5. ALL CONNECTIONS SHALL BE THE RESPONSIBILITY OF THE STEEL FABRICATOR. ALL CONNECTIONS SHALL BE
DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF TENNESSEE AND ENGAGED BY THE
STEEL FABRICATOR. FACTORED LOADS AT THE CONNECTIONS ARE SHOWN ON THE STRUCTURAL PLANS OR WILL
BE PROVIDED BY THE STRUCTURAL ENGINEER OF RECORD UPON REQUEST. THE STEEL FABRICATOR'S
CONNECTION DESIGNER SHALL SUBMIT CALCULATIONS TO THE STRUCTURAL ENGINEER OF RECORD FOR HIS
REVIEW. THE CALCULATIONS SHALL BE STAMPED WITH THE PROFESSIONAL REGISTRATION OF THE CONNECTION
DESIGNER. THE CONNECTION DESIGNER SHALL REVIEW AND STAMP ALL SHOP DRAWINGS CONCERNING HIS
CONNECTION DESIGNS. SHOP DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD
AFTER THEY HAVE BEEN STAMPED APPROVED BY THE GENERAL CONTRACTOR AND AFTER THE CONNECTION
DESIGNER HAS REVIEWED AND STAMPED THE SHOP DRAWINGS WITH HIS PROFESSIONAL REGISTRATION.
6. SHEAR CONNECTIONS FOR ALL COMPOSITE AND NON-COMPOSITE BEAMS SHALL BE DESIGNED FOR THE
REACTION SHOWN ON THE PLAN. IF NO REACTION IS SHOWN ON THE PLAN, SHEAR CONNECTIONS FOR NON-
COMPOSITE BEAMS SHALL BE DESIGNED FOR THE LOAD CAPACITY OF A SIMPLE SPAN BEAM WITH CONTINUOUS
LATERAL SUPPORT.
7. SHOULD BOLTED CONNECTIONS BE CHOSEN TO SPLICE TRUSS MEMBERS, THE CONNECTIONS SHALL BE
DESIGNED AS SLIP CRITICAL.
8. STRUCTURAL STEEL SHALL MEET THE FOLLOWING ASTM SPECIFICATIONS:
• STRUCTURAL PIPE:
• WALL THICKNESS: >0.625, A53 TYPE E OR S, GRADE B
• WALL THICKNESS: <0.625, A500, GRADE B
• STRUCTURAL TUBE: A500 GRADE C
• STEEL WIDE FLANGE SECTIONS: A992, GRADE 50 UNLESS GRADE 65 IS NOTED ON THE DRAWINGS
• STEEL JOISTS: REFER TO PROVISIONS OF THE STEEL JOIST INSTITUTE
• COLUMN BASE PLATES: UP TO 4" THICK - A572, GRADE 50
OVER 4" THICK - A572, GRADE 42
• ALL OTHER FRAMING UNLESS NOTED OTHERWISE ON CONTRACT DOCUMENTS: A36.
1. STEEL FRAMING CONNECTIONS SHALL BE BOLTED OR WELDED. BOLTS SHALL BE A MINIMUM OF 3/4" DIAMETER
ASTM A325 OR AS INDICATED ON THE DRAWINGS. EACH FASTENER SHALL BE TIGHTENED TO THE MINIMUM
TENSION FOR THE SIZE AND GRADE OF FASTENER USED AS DETERMINED BY ONE OF THE FOLLOWING METHODS:
• TURN OF THE NUT (A.I.S.C.)
• CALIBRATED WRENCH
• LOAD INDICATOR WASHERS
• LOAD INDICATOR BOLTS
2. BURNING OF HOLES, CUTS, OR OTHER PENETRATIONS IN STRUCTURAL STEEL MEMBERS ARE NOT PERMITTED
WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
3. THE CONTACT SURFACES WITHIN SLIP CRITICAL CONNECTIONS SHALL BE FREE OF OIL, PAINT, LACQUER, OR
GALVANIZING.
4. STEEL BEAMS THAT BEAR ON MASONRY WALLS SHALL HAVE MASONRY ANCHORS AND SHALL BEAR EITHER ON
BOND BEAMS OR FILLED BLOCK CORES AND SHALL BEAR A MINIMUM OF 8" UNLESS SHOWN OTHERWISE.
5. BEAMS SHALL BE FABRICATED AND ERECTED WITH NATURAL CAMBER UP. ANY ADDITIONAL CAMBER IS CALLED
OUT ON THE DRAWINGS AS "C = 1-1/2".
6. ALL WELDS SHALL CONFORM TO ANSI/AWS D1.1, "STRUCTURAL WELDING CODE." ALL GROOVE WELDS SHOWN
ON CONTRACT DOCUMENTS SHALL PROVIDE COMPLETE JOINT PENETRATION UNLESS NOTED OTHERWISE.
WELDING SHALL BE DONE WITH E7018 ELECTRODES UNLESS NOTED OTHERWISE.
7. SHEAR STUDS OF COMPOSITE BEAMS SHALL BE 3/4" HEADED STUD COLD FINISHED CARBON STEEL, ASTM
A108-61T, GRADE 1015 OR 1020. REFER TO PLANS FOR NUMBER OF STUDS IN PARENTHESIS - SPACE EQUALLY.
8. [ ] DENOTES DEVIATION FROM STATED TOP OF STEEL ELEVATION IN INCHES.
9. GROUT USED IN GROUT BEDS UNDER COLUMN BASE PLATES SHALL BE CEMENT-BASED, NON-SHRINK GROUT.
THE GROUT SHALL EXHIBIT NO SHRINKAGE IN ACCORDANCE WITH ASTM C827 "TEST METHOD FOR EARLY
VOLUME CHANGE OF CEMENTITIOUS MIXTURES" AND SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH
OF 5,000 PSI WHEN TESTED IN ACCORDANCE WITH ASTM C109 "TEST METHOD FOR COMPRESSIVE STRENGTH OF
HYDRAULIC CEMENT MORTARS".
10. SHOP OR FIELD SPLICES NOT SHOWN ON THE CONTRACT DOCUMENTS SHALL BE SUBMITTED TO THE
STRUCTURAL ENGINEER FOR APPROVAL.
11. STRUCTURAL STEEL FRAMING SHALL BE ERECTED TRUE AND PLUMB IN ACCORDANCE WITH A.I.S.C. CODE OF
STANDARD PRACTICE. ANY FRAMING EXCEEDING TOLERANCES OF THE CODE OF STANDARD PRACTICE SHALL BE
CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AS DIRECTED BY THE STRUCTURAL ENGINEER.
12. THE STRUCTURAL STEEL ERECTOR SHALL PROVIDE TEMPORARY BRACING OF THE STRUCTURAL STEEL
FRAMEWORK AGAINST ALL GRAVITY CONSTRUCTION LOADS, STRUCTURE SELFWEIGHT, AND LATERAL LOADS, SUCH AS WIND. THIS BRACING SHALL REMAIN IN PLACE UNTIL THE FINAL SYSTEM FOR RESISTING LATERAL
LOADS IS IN PLACE AND EFFECTIVE AS APPROVED BY THE STRUCTURAL ENGINEER. THE ERECTOR SHALL
ENGAGE A QUALIFIED PROFESSIONAL ENGINEER LICENSED IN THE LOCATION OF THE PROJECT TO DESIGN A
PLAN AND SEQUENCE FOR ERECTION FOR THE LATERAL STABILITY OF THE STRUCTURAL STEEL FRAME DURING
CONSTRUCTION. THIS PROFESSIONAL ENGINEER SHALL SEAL THE PLANS AND SEQUENCE AND SUBMIT IT TO THE
ENGINEER OF RECORD FOR REVIEW.
13. STEEL COLUMNS EXTENDING BELOW GRADE AND NOT ENCASED WITH CONCRETE SHALL BE COATED WITH
BITUMASTIC.
14. STEEL LINTELS AND SHELF ANGLES ARE TO BE GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A384.
15. GALVANIZED STEEL AND ITS CONNECTORS SHALL CONFORM TO ASTM A123, ASTM A153, ASTM A384, AND THE
RECOMMENDATIONS OF THE "AMERICAN HOT DIP GALVANIZERS ASSOCIATION STANDARD SPECIFICATION".
ABRADED, SCRAPED, AND FIELD WELDED AREAS SHALL BE REPAIRED WITH ZINC-RICH PAINT.
STEEL DECK
1. COMPLY WITH APPLICABLE PROVISIONS OF THE FOLLOWING SPECIFICATIONS :
• AMERICAN IRON AND STEEL INSTITUTE (AISI COLD FORMED STEEL DESIGN MANUAL)
• AMERICAN WELDING SOCIETY (ANSI/AWS D1.3 STRUCTURAL WELDING CODE – SHEET STEEL)
• AMERICAN WELDING SOCIETY (ANSI/AWS D1.1 STRUCTURAL WELDING CODE – STEEL)
• STEEL DECK INSTITUTE (SDI)
2. PROTECT STEEL DECK FROM CORROSION, DEFORMATION, AND OTHER DAMAGE DURING DELIVERY, STORAGE, AND HANDLING.
3. FLOOR AND ROOF DECKING SHALL BE INSTALLED IN ACCORDANCE WITH THE STEEL DECK
INSTITUTE AND MANUFACTURER'S RECOMMENDATIONS.
4. THE DECK MANUFACTURER SHALL FURNISH RIDGE AND VALLEY PLATES, FLAT PLATES OR ANGLES
AT CHANGE OF DECK DIRECTION, AND/OR SUMP PANS, TO PROVIDE A FINISHED SURFACE FOR THE
APPLICATION OF THE ROOFING MATERIAL.
5. WHERE WELDING IS ACCEPTED, THE SELECTION OF ELECTRODE AND AMPERAGE IS LEFT TO THE
CONTRACTOR. WELDING WASHERS ARE REQUIRED FOR DECK WITH A THICKNESS LESS THAN 0.028
INCHES AND ARE OPTIONAL FOR HEAVIER SECTIONS. PUDDLE WELDS SHALL BE AT LEAST 5/8 INCH
VISIBLE DIAMETER AND SHALL PENETRATE ALL LAYERS OF DECK MATERIAL AT END LAPS AND SIDE
LAPS AND HAVE GOOD FUSION TO THE SUPPORTING MEMBER. FIELD WELDING OF DECK SHALL BE
IN ACCORDANCE WITH ANSI/AWS D1.3 “STRUCTURAL WELDING CODE – SHEET METAL”. METAL DECK
SHALL BE INSTALLED AND WELDED BEFORE THE TEMPORARY BRACING IS REMOVED.
6. DECKING SHALL BE PLACED IN A THREE-SPAN CONTINUOUS CONDITION WHERE POSSIBLE. SINGLE
AND DOUBLE SPAN CONDITIONS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
7. SUBMITTED SHOP DRAWINGS SHALL SHOW THE DECK LAYOUT, TYPE OF DECK, ANCHORAGE
DETAILS, SUPPLEMENTAL FRAMING, CUT OPENINGS, AND ACCESSORIES.
8. STEEL DECK SHALL BE FABRICATED FROM STEEL CONFORMING TO SECTION A3 OF THE LATEST
EDITION OF SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS
(AISI). DECK SHALL BE MANUFACTURED FROM STEEL CONFORMING TO ASTM A1008, GRADES C OR
D, OR A653, STRUCTURAL QUALITY. THE MINIMUM FINISH SHALL BE A GALVANIZED COATING AS
DEFINED IN ASTM A653, G60. THE STEEL USED SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
9. COMPOSITE SHEAR STUDS SHALL BE WELDED (AWS D1.1 SECTION 7) THROUGH THE DECK OR
DIRECTLY TO THE STEEL MEMBER.
PRE-ENGINEERED METAL BUILDING
1. ALL DESIGN AND SHOP DRAWINGS SHALL BE PREPARED UNDER THE SUPERVISION OF A PROFESSIONAL
ENGINEER REGISTERED IN THE STATE OF TENNESSEE AND SHALL BEAR THE ENGINEER'S SEAL.
2. DESIGN BY MANUFACTURER SHALL INCLUDE ALL TEMPORARY BRACING REQUIRED FOR INSTALLATION.
BRACING SHALL BE SHOWN ON SHOP DRAWINGS.
3. GIRTS SHALL BE DESIGNED TO RESIST LATERAL LOADS.
4. MANUFACTURER SHALL PROVIDE FOUNDATION DESIGN LOADS.
5. ANCHOR BOLTS SHALL BE DESIGNED AND SUPPLIED BY MANUFACTURER AND INSTALLED BY THE
GENERAL CONTRACTOR.
POST-INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE DRAWINGS. CONTRACTOR
SHALL OBTAIN APPROVAL FROM ENGINEER OF RECORD (EOR) PRIOR TO USING POST-INSTALLED
ANCHORS FOR MISSING OR MISPLACED CAST-IN-PLACE ANCHORS.
2. CARE SHALL BE GIVEN TO AVOID CONFLICTS WITH EXISTING REBAR WHEN DRILLING HOLES. HOLES
SHALL BE DRILLED AND CLEANED PER THE MANUFACTURER'S INSTRUCTIONS. ANCHORS SHALL BE
INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AT NOT LESS THAN MINIMUM
EDGE DISTANCES AND/OR SPACINGS INDICATED IN THE MANUFACTURER'S LITERATURE.
3. SPECIAL INSPECTION SHALL BE PROVIDED FOR ALL ADHESIVE AND MECHANICAL ANCHOR
INSTALLATIONS AS REQUIRED BY THE 2018 INTERNATIONAL BUILDING CODE. INDEPENDENT ON-SITE
PROOF LOAD TESTING SHALL BE PERFORMED AS REQUIRED BY THE EOR. CONTACT EOR FOR AMOUNT
OF ANCHORS REQUIRED TO BE TESTED AND REQUIRED ROOF LOAD MAGNITUDE.
4. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE LISTED ON THE DRAWINGS SHALL BE
SUBMITTED TO THE EOR WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY A REGISTERED
PROFESSIONAL ENGINEER IN THE STATE OF TENNESSEE SHOWING THAT THE SUBSTITUTED PRODUCT
WILL ACHIEVE AN EQUIVALENT CAPACITY USING THE APPROPRIATE DESIGN PROCEDURE REQUIRED BY
THE 2018 INTERNATIONAL BUILDING CODE. PRODUCT ICC-ES CODE REPORTS SHALL BE INCLUDED WITH
SUBMITTAL PACKAGE.
5. AN ICC-ES EVALUATION REPORT SHALL BE PROVIDED FOR ALL POST-INSTALLED ANCHORS.
6. FOR ANCHORING INTO CONCRETE:
• MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE
WITH ACI 355.2 AND ICC-ES AC193.
• ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH
ACI 355.4 AND ICC-ES AC308.
7. FOR ANCHORING INTO MASONRY:
• MECHANICAL ANCHORS USED FOR ANCHORAGE TO SOLID-GROUTED CONCRETE MASONRY
SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC01 OR
ICC-ES AC106.
• ADHESIVE ANCHORS USED FOR ANCHORAGE TO SOLID-GROUTED CONCRETE MASONRY SHALL
HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC58.
• MECHANICAL ANCHORS USED FOR ANCHORAGE TO HOLLOW CONCRETE MASONRY SHALL
HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC58.
SPECIAL INSPECTIONS AND TESTING (2018 IBC)
1. THE GOVERNMENT SHALL EMPLOY AN INDEPENDENT TESTING COMPANY TO PERFORM THE FOLLOWING
ON SITE INSPECTIONS AND TESTING USING THE DESIGNATED 2018 IBC SECTION:
· STEEL CONSTRUCTION SECTION 1705.2
· CONCRETE CONSTRUCTION SECTION 1705.3
· SOILS SECTION 1705.6
2. UCOR/DOE SHALL EMPLOY A DESIGN PROFESSIONAL REGISTERED IN THE STATE OF TENNESSEE TO
PERFORM STRUCTURAL OBSERVATIONS IN ACCORDANCE WITH IBC SECTION 1704.2.
3. SPECIAL INSPECTORS SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND TO THE
ENGINEER OF RECORD INACCORDANCE WITH IBC SECTION 1704.2.4. THE REPORTS SHALL INDICATE
THAT WORK INSPECTED WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION
DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR
CORRECTION. IF THE DISCREPANCIES ARE NOT CORRECTED, THE BUILDING OFFICIAL AND THE
ENGINEER OF RECORD SHALL BE NOTIFIED.
REINFORCED MASONRY
1. ALL MASONRY CONSTRUCTION SHALL COMPLY WITH THE LATEST EDITION OF ACI 530/ASCE 5/TMS 402, "BUILDING
CODE REQUIREMENTS FOR MASONRY STRUCTURES".
2. ALL CONCRETE MASONRY UNITS FOR LOAD-BEARING WALLS SHALL CONFORM TO ASTM C-90, "STANDARD
SPECIFICATION FOR LOAD-BEARING CONCRETE MASONRY UNITS". TYPE M OR S MORTAR SHALL BE USED.
3. ALL LOAD-BEARING BLOCK MASONRY SHALL HAVE A MINIMUM PRISM STRENGTH OF 2,000 PSI. CONCRETE OR
GROUT USED FOR FILLING CELLS SHALL HAVE A MINIMUM STRENGTH OF 3,000 PSI.
4. ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED VERTICAL
CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND CROSS WEBS FORMING SUCH CELLS TO BE FILLED SHALL
BE FULL-BEDDED IN MORTAR TO PREVENT LEAKAGE OF GROUT. ALL HEAD (OR END) JOINTS SHALL BE SOLIDLY
FILLED WITH MORTAR FOR A DISTANCE IN FROM THE FACE OF THE WALL OR UNIT NOT LESS THAN THE
THICKNESS OF THE LONGITUDINAL FACE SHELLS. BOND SHALL BE PROVIDED BY LAPPING UNITS IN SUCCESSIVE
VERTICAL COURSES OR BY EQUIVALENT MECHANICAL ANCHORAGE.
5. VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED, CONTINUOUS VERTICAL CELL MEASURING NOT LESS THAN 3" AND HAVING A CLEAR AREA OF 10
SQUARE INCHES.
6. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF ALL CELLS TO BE FILLED IN EACH POUR OF
GROUT WHERE SUCH GROUT POUR IS IN EXCESS OF 4 FEET IN HEIGHT. ANY OVERHANGING MORTAR OR OTHER
OBSTRUCTION OR DEBRIS SHALL BE REMOVED FROM THE INSIDES OF SUCH CELL WALLS. THE CLEANOUTS
SHALL BE SEALED BEFORE GROUTING, AFTER INSPECTION.
7. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND AT INTERVALS NOT
EXCEEDING 192 DIAMETERS OF THE REINFORCEMENT OR 10 FEET.
8. ALL CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLIDLY WITH GROUT. GROUT SHALL BE POURED IN
LIFTS OF 8 FEET MAXIMUM HEIGHT. ALL GROUT SHALL BE CONSOLIDATED AT TIME OF POURING BY PUDDLING
OR VIBRATING AND THEN RECONSOLIDATED AGAIN BY PUDDLING LATER, BEFORE PLASTICITY IS LOST.
9. WHEN TOTAL GROUT POUR EXCEEDS EIGHT FEET IN HEIGHT, THE GROUT SHALL BE PLACED IN FOUR-FOOT LIFTS
AND SPECIAL INSPECTION DURING GROUTING SHALL BE REQUIRED. MINIMUM CELL DIMENSION SHALL BE THREE
INCHES.
10. WHEN THE GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL CONSTRUCTION JOINTS SHALL BE
FORMED BY STOPPING THE POUR OF GROUT NOT LESS THAN 1/2 INCH BELOW THE TOP OF THE UPPERMOST UNIT
GROUTED.
11. THE STRUCTURAL ENGINEER SHALL BE GIVEN A MINIMUM 24 HOURS NOTICE PRIOR TO EACH REINFORCED
BLOCK GROUTING OR CONCRETING OPERATION.
12. WHERE BOND BEAMS ARE INTERRUPTED BY STRUCTURAL STEEL COLUMNS OR BEAMS, BOND BEAM
REINFORCING SHALL BE WELDED TO THE COLUMN OR BEAM TO PROVIDE CONTINUITY OF THE BOND BEAM.
13. MASONRY WALLS SHALL BE REINFORCED WITH #5 @ 24" C.C. VERTICAL UNLESS NOTED OTHERWISE ON PLANS
OR SECTIONS. PROVIDE 2 – #5 VERTICAL BARS EACH SIDE OF OPENINGS AND EXTEND A MINIMUM OF 3'-0"
BEYOND OPENINGS. HORIZONTAL JOINT REINFORCEMENT SHALL CONSIST OF 9 GAUGE STANDARD LADDER
JOINT REINFORCEMENT SPACED AT 16" C.C. PROVIDE BOND BEAM AT MAXIMUM VERTICAL SPACING OF 3'-0" C.C.
REINFORCED WITH (2) #5 BARS SPACED AT 8'-0" C/C MAX.
14. NO BACKFILLING AGAINST BASEMENT AND RETAINING WALLS SHALL BE PERFORMED UNTIL THE GROUT AND
SUPPORTING FLOORS HAVE REACHED 100% OF THE DESIGN STRENGTH.
ABBREVIATION
ALT
APPROX
ARCH
BLDG
BRG
C c/c
CIP
CJ
CL
CLR
CMU
COL
CONC
CONST
CONT
db
DBL
DEG
DIA
DIAG
DL
DWG(S)
EA
EF
EJ
EL
ENGR
EOD
EOS
EQ
EW
FFE
FND
F.S.
FTG
GA
GALV
GB
GR
HORIZ
HT
INFO
K
KLF
KSF
LL
LLH
LLV
MAX
MECH
MEP
MEZZ
MIN
MISC
MP
Mu
NIC
NO
N.S.
NTS
OH
OPP
PG
PL
PSF
PSI
PT
REF
REINF
REQ'D
SDL
SECT
SF
SIM
SLV
SOG
STD
T
T&B
TB
TEMP
THK
TLS
TYP
UNO
V
VEJ
VERT
VIF
w/ w/o
WP
WWF
DESCRIPTION
ALTERNATE
APPROXIMATE
ARCHITECT OR ARCHITECTURAL DRAWINGS
BUILDING
BEARING
FACTORED COMPRESSION
CENTER ON CENTER
CAST-IN-PLACE
CONTROL JOINT
CENTER LINE
CLEAR OR CLEARANCE
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONSTRUCTION
CONTINUOUS
REINFORCING BAR DIAMETER
DOUBLE
DEGREE
DIAMETER
DIAGONAL
DEAD LOAD
DRAWING(S)
EACH
EXTERIOR FACE
EXPANSION JOINT
ELEVATION
ENGINEER
EDGE OF DECK
EDGE OF SLAB
EQUAL
EACH WAY
FINISH FLOOR ELEVATION
FOUNDATION
FAR SIDE
FOOTING
GAUGE
GALVANIZED
GRADE BEAM
GRADE
HORIZONTAL
HEIGHT
INFORMATION
KIP
KIP PER LINEAR FOOT
KIP PER SQUARE FOOT
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MAXIMUM
MECHANICAL
MECHANICAL, ELECTRICAL, PLUMBING
MEZZANINE
MINIMUM
MISCELLANEOUS
MICROPILE
FACTORED MOMENT
NOT IN CONTRACT
NUMBER
NEAR SIDE
NOT TO SCALE
OPPOSITE HAND
OPPOSITE
PLATE GIRDER
PLATE
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POST-TENSIONED
REFERENCE
REINFORC(ED) OR (ING)
REQUIRED
SUPERIMPOSED DEAD LOAD
SECTION
SQUARE FEET
SIMILAR
SHORT LEG VERTICAL
SLAB-ON-GRADE
STANDARD
FACTORED TENSION
TOP AND BOTTOM
TIE BEAM
TEMPERATURE
THICK
TENSION LAP SPLICE
TYPICAL
UNLESS NOTED OTHERWISE
FACTORED SHEAR
VERTICAL EXPANSION JOINT
VERTICAL
VERIFY IN FIELD
WITH
WITHOUT
WORK POINT
WELDED WIRE FABRIC
ABBREVIATION LIST
2 2 a a
2a2a a a
ROOF PLAN
45 5 a
WALL ELEVATION
a
NOTE:
THESE ARE FOR Iws = 1.00 & EXP. C. VALUES ARE BASED ON
AN EFFECTIVE WIND AREA OF 10 SF.
DIMENSION "a" IS DEFINED IN ASCE 7-16 AS 10% OF LEAST
HORIZONTAL DIMENSION, BUT NOT LESS THAN 3' - 0".
GENERAL NOTES FOR SECTIONS AND DETAILS:
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
DETAIL NUMBER
SHEET ON WHICH
SECTION IS SHOWN
SECTION MARKER
DETAIL CALLOUT
BUILDING ELEVATION MARKER
DETAIL NUMBER
PROJECT NORTH ARROW
REVISION CLOUD
REVISION DELTA
NUMBER
BRICK / MASONRY CONCRETE
MASONRY
UNIT (CMU)
EARTH GRAVEL FILL RIGID
INSULATION
MATERIALS LEGEND
HXXX
HXXX
HXXX
TYPICAL DETAIL MARKER
NOTE:
THIS SEQUENCIAL MARKER IS PART OF THE
DETAIL TITLE ON THE SHEET WHERE THE
DETAIL IS SHOWN. THIS MARKER IS NOT
REFERENCED ANYWHERE ELSE IN THE
DOCUMENTS.
N
HXXX
SHEET ON WHICH
SECTION IS TAKEN
DIRECTION OF CUT
HXXX
SHEET ON WHICH
SECTION IS TAKEN
CALL OUT
HXXX SHEET ON WHICH
ELEVATION IS SHOWN
SHEET ON WHICH
ELEVATION IS TAKEN
AGRICULTURE
K
UR
T BOYD
R E G
IS
TE
RED ENG IN
E E R
N o . 1 0 4 5 7 2
C O M M E R C E
S T A
T E
OF T ENNE
S
S E E
UCOR
PROJECT NAME:
SITE CLASS
TYPE REV
RPE
DATE
DRAWING REVISIONS
SCALE:LE DRAWING NUMBER
BUILDING
ELECTRONIC SIGNATURES
PROFESSIONAL SEAL
TITLE:
CD
U
ORG/
ENGR
ENGR
CHK
PROJ
ENGR
KAREA ETTP
PROJECT RECORD NUMBER:
AS SHOWN
CONFIGURATION MANAGEMENT LEVEL
DE-SC-0004645
an AECOM-led partnership with Jacobs
MANAGED FOR THE DEPARTMENT OF ENERGY
UNDER CONTRACT NUMBER DE-SC-0004645
OAK RIDGE TN 37830
OAK RIDGE RESERVATION
03/31/2022 CFC SUBMITTAL DLP SKR KAB KAB
ARCHITECTSSMEE + BUSBY
Knoxville, TN 37902
DRW
BY
KAB
QA
KAB0
REV. DATE DESCRIPTION
141101.11
BUILDING DESIGN K-25 PHASE II
GENERAL NOTES
S1E-700NHP-H712
01/20/2023
WIRE MESH SUPPORT SPACING REQUIREMENTS
WIRE SIZE WIRE SPACING SUPPORT SPACING
W OR D9 AND LARGER 12" AND GREATER 4' - 0" TO 6' - 0"
W OR D5 TO W OR D8 12" AND GREATER 3' - 0" TO 4' - 0"
W OR D9 AND LARGER LESS THAN 12" 3' - 0" TO 4' - 0"
W OR D4 OR W OR D8 LESS THAN 12" 2' - 0" TO 3' - 0"
LESS THAN W OR D4 LESS THAN 12" 2' - 0" TO 3' - 0" OR LESS
TABLE OF CONCRETE MIX DESIGN REQUIREMENTS
MEMBER TYPE/LOCATION
28 DAY
STRENGTH (PSI)
EXPOSURE
CATEGORY
MAXIMUM
W/C RATIO
AIR
CONTENT
MAXIMUM UNIT
WEIGHT (PCF)
INTERIOR SLAB-ON-GRADE 3000 F0 0.45 - 145
EXTERIOR SLAB-ON-GRADE 4500 F1 0.45 4.5%-7.5% 145
FOOTINGS 3000 F0 0.45 - 145
INTERIOR WALLS * 4000 F0 0.45 - 145
EXTERIOR WALLS 4500 F1 0.45 4.5%-7.5% 145
SLABS ON COMPOSITE METAL DECK 4000 F0 0.45 4% - 7% 125
COMPONENTS AND CLADDING ULTIMATE WIND LOADS (Based on 10ft² effective area)
ROOF (PSF) WALL (PSF)
ZONE 1 ZONES 2 & 3 ZONE 4 ZONE 5
19.3, -44.2 19.3, -44.2 19.3,-20.9 19.3,-25.7
STRUCTURAL SHEET INDEX
DRAWING NUMBER TITLE
S1E-700NHP-H712 GENERAL NOTES
S1E-700NHP-H713 SPECIAL INSPECTIONS
S1E-700NHP-H714 TYPICAL DETAILS - STEEL
S1E-700NHP-H715 TYPICAL DETAILS - FOUNDATION
S1E-700NHP-H716 TYPICAL DETAILS - CONCRETE MASONRY
S1E-700NHP-H717 LEVEL 01 FOUNDATION PLAN
S1E-700NHP-H718 LEVEL 02 FRAMING PLAN
S1E-700NHP-H719 ROOF FRAMING PLAN
S1E-700NHP-H720 SCHEDULES AND DIAGRAMS
S1E-700NHP-H721 BRACED FRAMING AND CMU ELEVATIONS
S1E-700NHP-H722 FOUNDATION SECTIONS
S1E-700NHP-H723 FRAMING SECTIONS
S1E-700NHP-H878 FRAMING CONNECTIONS
S1E-700NHP-H879 MISCELLANEOUS CONNECTIONS
10/06/20221
REVISED CFC - REVISION CLOUDS AND TRIANGLES REMOVED TO
PRODUCE A CLEAN DRAWING SET FOR USACE TO START PROCUREMENT
DLP SKR KAB KAB
KAB KAB
01/20/20232 CLARIFICATIONS IN RESPONSE TO BIDDER QUESTIONS
DLP SKR KAB KAB KAB KAB
A B C D E
STAIR
S101
VESTIBULE
MEN'S RESTROOM
WOMEN'S RESTROOM
JANITOR'S CLOSET
EQUIPMENT ROOM
EXHIBIT AREA
STORAGE
SPRINKLER RISER ROOM
OFFICE
ELEC ROOM
ELEV MACHINE ROOM
VESTIBULE
MONUMENTAL STAIR
S102
EF-1
EF-2
EF-3
EXHAUST WALL LOUVER,
RUSKIN MODEL ELF375DX
OR APPROVED EQUAL.
6" ø
6" ø
6"ø
DSS-3
U/C
U/C
U/C
6" ø
8" ø
"ø
8" ø
CD-1(12x12)
150 CFM
CD-1(12x12)
150 CFM
CD-1(12x12)
70 CFM
CD-1(12x12)
160 CFM
EH-2
ELEVATOR
TTRTU1 TTRTU2
U/C
U/C U/C
U/C
T
TDSS2
T TDSS3
T TEH1
T TEH2
CD-1(12x12)
70 CFM
PAINT EXPOSED DUCT AND TOPS OF
ROOMS BLACK (TYP. OF FIRST FLOOR).
8" ø
10"ø
6"ø
8" ø
EH-1
8"ø
DSS-2
T TDSS1
DSS-1
U/C
10"Ø FROM ROOF ABOVE.
10"Ø FROM ROOF ABOVE.
SWS-1(10x4)
150 CFM
10"Ø FROM RTU-3 ABOVE.
6"ø
6" ø
SWS-1(10x4)
150 CFM
UCOR
PROJECT NAME:
SITE CLASS
TYPE REV
RPE
DATE
DRAWING REVISIONS
SCALE:LE DRAWING NUMBER
BUILDING
ELECTRONIC SIGNATURES
PROFESSIONAL SEAL
TITLE:
CD
U
ORG/
ENGR
ENGR
CHK
PROJ
ENGR
KAREA ETTP
PROJECT RECORD NUMBER:
AS SHOWN
CONFIGURATION MANAGEMENT LEVEL
DE-SC-0004645
an AECOM-led partnership with Jacobs
MANAGED FOR THE DEPARTMENT OF ENERGY
UNDER CONTRACT NUMBER DE-SC-0004645
OAK RIDGE TN 37830
OAK RIDGE RESERVATION
3/31/2022 CFC SUBMITTAL
ARCHITECTSSMEE + BUSBY
Knoxville, TN 37902
DRW
BY
GS
QA
SB0
REV. DATE DESCRIPTION
21026
BUILDING DESIGN K-25
FIRST FLOOR HVAC PLAN
M1E-700NHP-H728
1/8" = 1'-0"
LEVEL 01 HVAC PLAN
CC PCH JWH PCH
1. ALL EXPOSED SUPPLY AND RETURN DUCTWORK BELOW ROOF TO BE PAINT GRIP, FLAT BLACK.
GENERAL NOTES:
CC PCH JWH PCH1/20/20231 SB GSCLARIFICATIONS IN RESPONSE TO BIDDER QUESTIONS
A B C D E
VIEWING PLATFORM
"ø
"ø
"ø
22"Ø UP TO RTU-2 ON ROOF
22"Ø UP TO RTU-1 ON ROOF
22"Ø TO RTU-3 ON ROOF
"ø
"ø
"ø
"ø
COVER OPENING WITH
1/2" WIRE MESH
COVER OPENING WITH
1/2" WIRE MESH
SWS-1(16x4)
300 CFM
SWS-1(16x4)
300 CFM
SWS-1(16x4)
375 CFM
SWS-1(16x4)
375 CFM
SWS-1(16x4)
375 CFM
SWS-1(16x4)
375 CFM
SWS-1(16x4)
300 CFM
SWS-1(16x4)
300 CFM
"ø22 "ø
SWS-1(24x4)
450 CFM
SWS-1(24x4)
450 CFM
SWS-1(24x4)
450 CFM
SWS-1(24x4)
450 CFM
"ø
"ø
10"ø
10"ø
SWS-1(24x4)
450 CFM
SWS-1(24x4)
450 CFM
"ø
"ø
SWS-1(24x4)
450 CFM
SWS-1(24x4)
450 CFM
"ø
"ø
10"Ø DOWN TO
FLOOR BELOW
10"Ø DOWN TO
FLOOR BELOW
SWS-1(24x4)
450 CFM
SWS-1(24x4)
450 CFM
SWS-1(24x4)
425 CFM
SWS-1(24x4)
400 CFM
SWR-1(36x18)
2540 CFM
ELEVATOR
MECHANICAL
"ø
"ø
"ø
TTRTU3
22"Ø UP
21'-0" A.F.F.
21'-0" A.F.F.
21'-0" A.F.F. 21'-0" A.F.F.
14'-0" A.F.F.
UCOR
PROJECT NAME:
SITE CLASS
TYPE REV
RPE
DATE
DRAWING REVISIONS
SCALE:LE DRAWING NUMBER
BUILDING
ELECTRONIC SIGNATURES
PROFESSIONAL SEAL
TITLE:
CD
U
O…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .