This document is a Questions and Answers (Q&A) file related to a federal contract opportunity for the installation of fiber optic cabling. The project aims to extend connectivity and provide a pathway for future redundancy within a given building at Camp Dawson in Kingwood, West Virginia.

The key details include:

  • Gel-filled fiber optic cable can be replaced with gel-free (Corning) type, which is easier to maintain.
  • Manholes have minimal mud and water present.
  • Fiber loops are required at all splice locations within the buildings, with each loop being approximately 25 feet long.
  • Two-way OTDR testing is acceptable, and the test results are to be provided to the customer in digital and hard copy formats.
  • Two additional Tripp-Lite SR45UB cabinets are required for future expansion, and the new outlets are to be fed from switches located in room 1220.
  • Payment/performance bonds are not required, and site visits are possible with prior coordination.
  • The solicitation number is W912L8-24-Q-0053, and the contracting agency is the West Virginia Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to Fiber Optic Cabling, newest first.
File Type Posted
RFQ Provisions and Clauses for RTI Fiber.docx DOCX document
RTI Fiber objectives 1.docx DOCX document
RTI SOW Attachment A Overview.pdf PDF
SOW RTI Fiber Statement of Work.docx DOCX document
RTI SOW Attachment B Cable Route.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

national guard bureau

United states property and fiscal office west virginia national guard 50 aRMORY ROAD

BUCKHANNON, WEST VIRGINIA 26201-2052

RTI Fiber Optic Cabling Installation/W912L8-24-Q-0053 Contact: Juan H. Arevalo EMAIL: juan.h.arevalojimenez.civ@army.mil Phone Number: 304-473-5226 Q&A Revised: September 5th , 2024 Questions and Answers

1. Can gel-filled fiber optic cable be replaced with gel-free (Corning) type? (Both are designed to block water penetration but gel-free is easier to maintain.)

Yes, dry water block is acceptable.

2. Is water or mud likely to be present in handholes and manholes?

Manholes have minimal mud and water.

3. Do you require extra fiber loops in handholes, manholes, or termination points? If so, how long?

Fiber loops are not required in the manholes. Cable must be routed around the perimeter and properly secured to racking or walls in the manholes. Fiber loops are required at all splice locations within the buildings. Each loop is to be approximately 25’.

4. Will visible light source and OTDR at typical wavelengths be sufficient for cable testing? For OTDR, will it be one-way or two-way testing?

VLS and two-way OTDR testing is acceptable. OTDR test results are to be provided to the customer in digital and hard copy formats.

5. Page 5 of SOW, paragraph 2.4:

a. Please confirm that TWO new cabinets Tripp-Lite SR45UB are needed.

Two additional cabinets are required for future expansion.

b. Will the new outlets be on dedicated circuits? If so, how far is the distribution panel?

The new outlets are to be fed from switches located in room 1220. See OPS Room 1220 Configuration Drawing.

5.Are payment/performance bonds required? NO
6.Site Visit possible?

Yes, with prior coordination.