These technical design documents detail the specifications for a three-person workstation for the Tennessee Army National Guard Joint Emergency Operations Center (EOC). The design includes precise schematics for a custom workstation with multiple technical requirements: high-pressure laminate work surfaces in crisp linen color, slate-colored panels, black metal accents, three dimmable task lights, 6-outlet power bars, hinged monitor access lids, panel locks, low-profile monitor mounts supporting up to 34" monitors, and electrical lift systems with independent configurations. Each workstation will accommodate individual 30"-38" work areas with specific dimensional requirements for floor clearance, panel depths, and electrical component housing.
The solicitation (W912L7-25-Q-1613) is a small business set-aside competitive procurement seeking a firm-fixed price contract for furnishing, assembling, and installing these workstations. Key procurement details include a 15 July 2025 10:00 AM CST proposal submission deadline, 30-60 calendar day delivery preference, and evaluation criteria focusing on technical compliance, pricing, and vendor past performance. The Tennessee Army National Guard requires complete workstation delivery to their Nashville, TN facility, with the government providing power connection services. Warranty terms include lifetime coverage for structural components, five-year coverage for electrical components, and extended original equipment manufacturer (OEM) warranties.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVISIONS:
REV. DESCRIPTION BY DATE QUOTE REF.
DRAWN BY:
CHECKED BY:
SUBMITTAL DATE:
DRAWING NO.
PROJECT NO.
SHEET NO.
of 06
Tennessee National Guard EOC REVISION NO.
0ISOMETRIC
CONCEPTIONAL IMAGE ONLY
1 2 3
REV. DESCRIPTION BY DATE QUOTE REF.
DRAWN BY:
CHECKED BY:
SUBMITTAL DATE:
DRAWING NO.
PROJECT NO.
SHEET NO.
of 06
Tennessee National Guard EOC REVISION NO.
0FLOOR PLAN
X
AutoCAD SHX Text 36.00"
AutoCAD SHX Text 27.75"
AutoCAD SHX Text
EXISTING CONSOLES
AutoCAD SHX Text
NOTES: 1. OPERATOR POSITION OPERATOR POSITION
A
REVISIONS:
REV. DESCRIPTION BY DATE QUOTE REF.
0 ISSUED FOR DESIGN
DRAWN BY:
CHECKED BY:
DRAWING NO.
PROJECT NO.
SHEET NO.
of 06
Tennessee National Guard EOC REVISION NO.
0CONSOLE PLAN & ELEVATION (QTY 1)
AutoCAD SHX Text 36.00"
AutoCAD SHX Text 39.00"
AutoCAD SHX Text
MONITOR LIFT SYSTEM
AutoCAD SHX Text
GROMMET
AutoCAD SHX Text
END PANEL
AutoCAD SHX Text
ARTICULATING TASK LIGHT
AutoCAD SHX Text
KEYBOARD & MOUSE (BY OTHERS)
AutoCAD SHX Text
MOLDED PVC NOSING
AutoCAD SHX Text
HIGH PRESSURE LAMINATE (HPL) WORKSURFACE
AutoCAD SHX Text
ARTICULATING TASK LIGHT
AutoCAD SHX Text
34" DISPLAY MONITOR (BY OTHERS)
AutoCAD SHX Text
END PANEL
AutoCAD SHX Text
34" DISPLAY MONITOR (BY OTHERS)
AutoCAD SHX Text
6-OUTLET POWERBAR (QTY 1 PER OPERATOR POSITION)
AutoCAD SHX Text
HINGED FRONT PANEL
AutoCAD SHX Text
MONITOR LIFT SYSTEM
AutoCAD SHX Text
FRONT & REAR PANEL LOCKS
AutoCAD SHX Text
FIXED CPU SHELF
NOTES: 1. FINAL LOCATION OF POWER BARS AND FINAL LOCATION OF POWER BARS AND SUPPORT FEET TO BE DETERMINED DURING DETAILED ENGINEERING.
0 ISSUED FOR DESIGN I
DRAWN BY:
CHECKED BY:
DRAWING NO.
PROJECT NO.
SHEET NO.
of 06
Tennessee National Guard EOC REVISION NO.
0CONSOLE SECTIONS
A SECTION
A SECTION
AutoCAD SHX Text 28.50"
AutoCAD SHX Text 21.00"
AutoCAD SHX Text 21.00"
AutoCAD SHX Text 36.00"
AutoCAD SHX Text 36.00"
AutoCAD SHX Text 15.00"
AutoCAD SHX Text 15.00"
AutoCAD SHX Text
FLIP-UP SURFACE
AutoCAD SHX Text
34" DISPLAY MONITOR (BY OTHERS)
AutoCAD SHX Text
MONITOR LIFT SYSTEM
AutoCAD SHX Text
HINGED REAR PANEL
AutoCAD SHX Text
6 - OUTLET POWERBAR
AutoCAD SHX Text
FIXED CPU SHELF
AutoCAD SHX Text
HIGH PRESSURE PLASTIC LAMINATE (HPL) WORKSURFACE
AutoCAD SHX Text
MOLDED PVC NOSING
AutoCAD SHX Text
34" DISPLAY MONITOR (BY OTHERS)
AutoCAD SHX Text
FRONT & REAR PANEL LOCKS
HINGED FRONT PANEL
0 ISSUED FOR DESIGN 04 APR 25
DRAWN BY:
CHECKED BY:
DRAWING NO.
PROJECT NO.
SHEET NO.
of 06
Tennessee National Guard EOC REVISION NO.
0CONSOLE AVAILABLE SPACE FOR CPU
AVAILABLE SPACE FOR CPU UNDER MONITOR AVAILABLE SPACE FOR CPU BEHIND MONITOR
AutoCAD SHX Text 14.50"
AutoCAD SHX Text 4.00"
AutoCAD SHX Text 6.00"
8.00"
| Sheets and Views |
| 25-136 Tennessee Air National Guard EOC_r0-01 |
| 25-136 Tennessee Air National Guard EOC_r0-02 |
| 25-136 Tennessee Air National Guard EOC_r0-03 |
| 25-136 Tennessee Air National Guard EOC_r0-04 |
| 25-136 Tennessee Air National Guard EOC_r0-05 |
| 25-136 Tennessee Air National Guard EOC_r0-06 |
File details come from the government source that posted it. Updated .