240 W. Bessemer Street Alcoa, Tennessee 37701
ADDENDUM NO. 1
September 2, 2016
TO
SPECIFICATIONS AND DRAWINGS FOR
REPAIR BUILDING 406
MCGHEE TYSON AIR NATIONAL GUARD BASE
PSXE102033
Addendum Descriptions:
1. All FCUs shall include factory supplied supply and return air grilles.
2. Refer to Drawing M1.2: All concentric vent termination kits for the boilers and water heaters shall be stainless steel.
3. All Open Storage compartments in the dormitory room millwork shall have a stainless steel corner guard on the bottom edge of the millwork. Corner guard shall be ¾”x¾”, 90 degree, 16 gage, Type 304 SS, Satin #4 brushed finish.
4. FP3.1 fire protection pipe bracing details show wire rope/cable bracing. Rigid bracing may be required depending on the available overhead space and for coordination with the other building utilities, structural members, etc. No additional payment shall be made for rigid pipe bracing where required.
5. Provide a tether stop on all cabinet doors in the dormitory rooms. Product shall be
HAFELE Item #366.74.900, or approved equal.
6. Bid Question #25: Automatic Door Opener associated with the ABA push button shall be Door Motion Technologies commercial door operator DuraSwing 5 full time door operator, or approved equal.
7. All of the exterior hand railing shall receive factory powder coat finish in lieu of the clear anodized finish called out on the plans and specs. Color shall be Dove Gray.
Powder coat finish shall conform to AAMA 2605 High Performance requirements.
8. Door stops shall be installed for all of the Accessible Bedrooms. Door stop shall be floor mounted type No. 241F as manufactured by Hager Company with US26D finish, or approved equal.
9. Revised Glazing Specification 08800 provided with changes to Section 2.1 for
Insulating Glass Units.