09651_-_Resilient_Tile_Flooring_and_Accesories.pdf

PDF 43 KB Posted

Attached to
Renovate Building 1056 Federal contract opportunity
Solicitation number
W912L1-17-B-0002
Issued by
Department of the Army Texas Army National Guard

About this file

Tile flooring

View the file

Other files for this federal contract opportunity

Other files attached to Renovate Building 1056, newest first.
File Type Posted
W912L1-17-B-0002-0001.pdf PDF
09310A-Ceramic_Tile.pdf PDF
15440-Plumbing_Fixtures.pdf PDF
10801-Toilet_Room_Accessories.pdf PDF
08211-Flush_Wood_Doors.pdf PDF
09900_-_Painting.pdf PDF
Questions_and_Answers.docx DOCX document
06402-Interior_Architectural_Woodwork.pdf PDF
08710-Door_Hardware.pdf PDF
09680_-_Carpet.pdf PDF
09310B-Pocelain_Tile.pdf PDF
1056_Site_Plans_20160722.pdf PDF
SOW_-_1056_-_Renovate_for_SG_DSI_HG_20170324_Rev1.pdf PDF
1056_Dimensions.pdf PDF
Ellington_JRB_Design_Standard_20160615.pdf PDF
Standard_Finish_Schedule_&_Colors.jpg JPG image
Solicitation_W912L1-17-B-0002.pdf PDF
FWJH152260_SOW-_1056_-_Renovate_for_SG_DSI_HG_20170324.pdf PDF
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ellington Field ANGB Houston, Texas

Resilient Floor Tiles, Wall Base, and Accessories 09651-1

SECTION 09651

RESILIENT FLOOR TILE, WALL BASE, AND ACCESSORIES

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.

1.2 SUMMARY

A. This Section includes the following:

1. Vinyl composition tile (VCT).

2. Resilient wall base and accessories.

1.3 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Samples for Initial Selection: For each type of product indicated.

C. Samples for Verification: Full-size units of each color and pattern of resilient floor tile required.

1. Resilient Wall Base and Accessories: Manufacturer's standard-size Samples, but not less than 12 inches (300 mm) long, of each resilient product color and pattern required.

D. Maintenance Data: For resilient products to include in maintenance manuals.

1.4 DELIVERY, STORAGE, AND HANDLING

A. Store resilient products and installation materials in dry spaces protected from the weather, with ambient temperatures maintained within range recommended by manufacturer, but not less than 50 deg F (10 deg C) or more than 90 deg F (32 deg C). Store tiles on flat surfaces.

1.5 PROJECT CONDITIONS

A. Maintain temperatures within range recommended by manufacturer, but not less than 70 deg F (21 deg C) or more than 95 deg F (35 deg C), in spaces to receive floor tile during the following time periods:

1. 48 hours before installation.

2. During installation.

3. 48 hours after installation.

09651-2

B. After postinstallation period, maintain temperatures within range recommended by manufacturer, but not less than 55 deg F (13 deg C) or more than 95 deg F (35 deg C).

C. Close spaces to traffic during floor covering installation.

D. Close spaces to traffic for 48 hours after floor covering installation.

E. Install resilient products after other finishing operations, including painting, have been completed.

1.6 EXTRA MATERIALS

A. Furnish extra materials described below that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

1. Floor Tile: Furnish 1 box for every 50 boxes or fraction thereof, of each type, color, and pattern of floor tile installed.

2. Resilient Wall Base and Accessories: Furnish not less than 10 linear feet (3 linear m) for every 500 linear feet (150 linear m) or fraction thereof, of each type, color, pattern, and size of resilient product installed.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the products listed in other Part 2 articles.

2.2 COLORS AND PATTERNS

A. Colors and Patterns: As selected from manufacturer's full range.

2.3 VINYL COMPOSITION TILE

A. Vinyl Composition Tile (VCT): ASTM F 1066.

1. Armstrong World Industries, Inc.

2. Azrock Commercial Flooring, DOMCO.

3. Congoleum Corporation.

4. Mannington Mills, Inc..

5. Tarkett Inc.

B. Wearing Surface: Smooth.

C. Thickness: 0.125 inch (3.2 mm).

D. Size: 12 by 12 inches (305 by 305 mm).

09651-3

E. Fire-Test-Response Characteristics:

1. Critical Radiant Flux Classification: Class I, not less than 0.45 W/sq. cm per

ASTM E 648.

2.4 RESILIENT WALL BASE

A. Wall Base: Product complying with FS SS-W-40, Type II and with requirements specified in Resilient Tile Flooring Schedule on the Drawings. Color and pattern in accordance with Schedule.

1. Armstrong World Industries, Inc.

2. Azrock Commercial Flooring, DOMCO.

3. Burke Mercer Flooring Products.

4. Johnsonite.

5. Roppe Corporation.

B. Minimum Thickness: 0.125 inch (3.2 mm).

C. Height: 4 inches (102 mm).

D. Lengths: Cut lengths 48 inches (1219 mm) long or coils in manufacturer's standard length.

E. Outside Corners: Premolded.

F. Inside Corners: Job formed.

G. Surface: Smooth.

2.5 RESILIENT MOLDING ACCESSORIES

A. Description: [Cap for cove carpet] [Cap for cove resilient sheet floor covering] [Carpet bar for tackless installations] [Carpet edge for glue-down applications] [Nosing for carpet] [Reducer strip for resilient floor covering] [Joiner for tile and carpet] <Insert description>.

1. Burke Mercer Flooring Products.

2. Johnsonite.

3. Marley Flexco (USA), Inc.

4. Roppe Corporation.

5. Stoler Industries.

B. Material: Vinyl.

C. Profile and Dimensions: As indicated.

2.6 INSTALLATION MATERIALS

A. Trowelable Leveling and Patching Compounds: Latex-modified, portland cement based or blended hydraulic cement based formulation provided or approved by resilient product manufacturer for applications indicated.

09651-4

B. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated.

C. Metal Edge Strips: Extruded aluminum with mill finish of width shown, of height required to protect exposed edges of tiles, and in maximum available lengths to minimize running joints.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, with Installer present, for compliance with requirements for installation tolerances, moisture content, and other conditions affecting performance.

1. Verify that finishes of substrates comply with tolerances and other requirements specified in other Sections and that substrates are free of cracks, ridges, depressions, scale, and foreign deposits that might interfere with adhesion of resilient products.

2. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

A. Prepare substrates according to manufacturer's written recommendations to ensure adhesion of resilient products.

B. Concrete Substrates: Prepare according to ASTM F 710.

1. Verify that substrates are dry and free of curing compounds, sealers, and hardeners.

2. Alkalinity and Adhesion Testing: Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing.

3. Moisture Testing:

a. Perform anhydrous calcium chloride test, ASTM F 1869. Proceed with installation only after substrates have maximum moisture-vapor-emission rate of 3 lb of water/1000 sq. ft. (1.36 kg of water/92.9 sq. m) in 24 hours.

b. Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing.

C. Remove substrate coatings and other substances that are incompatible with adhesives and that contain soap, wax, oil, or silicone, using mechanical methods recommended by manufacturer.

Do not use solvents.

D. Use trowelable leveling and patching compound to fill cracks, holes, and depressions in substrates.

E. Move resilient products and installation materials into spaces where they will be installed at least 48 hours in advance of installation.

1. Do not install resilient products until they are same temperature as space where they are to be installed.

F. Sweep and vacuum clean substrates to be covered by resilient products immediately before installation. After cleaning, examine substrates for moisture, alkaline salts, carbonation, and dust. Proceed with installation only after unsatisfactory conditions have been corrected.

09651-5

3.3 TILE INSTALLATION

A. Lay out tiles from center marks established with principal walls, discounting minor offsets, so tiles at opposite edges of room are of equal width. Adjust as necessary to avoid using cut widths that equal less than one-half tile at perimeter.

1. Lay tiles in patterns indicated.

B. Match tiles for color and pattern by selecting tiles from cartons in the same sequence as manufactured and packaged, if so numbered. Discard broken, cracked, chipped, or deformed tiles.

1. Lay tiles in pattern of colors and sizes indicated.

C. Scribe, cut, and fit tiles to butt neatly and tightly to vertical surfaces and permanent fixtures including built-in furniture, cabinets, pipes, outlets, edgings, door frames, thresholds, and nosings.

D. Extend tiles into toe spaces, door reveals, closets, and similar openings.

E. Maintain reference markers, holes, and openings that are in place or marked for future cutting by repeating on floor tiles as marked on substrates. Use chalk or other nonpermanent, nonstaining marking device.

F. Install tiles on covers for telephone and electrical ducts and similar items in finished floor areas.

Maintain overall continuity of color and pattern with pieces of tile installed on covers. Tightly adhere tile edges to substrates that abut covers and to cover perimeters.

G. Adhere tiles to flooring substrates using a full spread of adhesive applied to substrate to produce a completed installation without open cracks, voids, raising and puckering at joints, telegraphing of adhesive spreader marks, and other surface imperfections.

3.4 RESILIENT WALL BASE INSTALLATION

A. Apply wall base to walls, columns, pilasters, casework and cabinets in toe spaces, and other permanent fixtures in rooms and areas where base is required.

B. Install wall base in lengths as long as practicable without gaps at seams and with tops of adjacent pieces aligned.

C. Tightly adhere wall base to substrate throughout length of each piece, with base in continuous contact with horizontal and vertical substrates.

D. Do not stretch wall base during installation.

E. On masonry surfaces or other similar irregular substrates, fill voids along top edge of wall base with manufacturer's recommended adhesive filler material.

F. Premolded Corners: Install premolded corners before installing straight pieces.

G. Job-Formed Corners:

09651-6

1. Inside Corners: Use straight pieces of maximum lengths possible. Form by cutting an inverted V-shaped notch in toe of wall base at the point where corner is formed. Shave back of base where necessary to produce a snug fit to substrate.

3.5 CLEANING AND PROTECTION

A. Perform the following operations immediately after completing resilient product installation:

1. Remove adhesive and other blemishes from exposed surfaces.

2. Sweep and vacuum surfaces thoroughly.

3. Damp-mop surfaces to remove marks and soil.

a. Do not wash surfaces until after time period recommended by manufacturer.

B. Protect resilient products from mars, marks, indentations, and other damage from construction operations and placement of equipment and fixtures during remainder of construction period.

Use protection methods recommended in writing by manufacturer.

1. Apply protective floor polish to horizontal surfaces that are free from soil, visible adhesive, and surface blemishes if recommended in writing by manufacturer.

a. Use commercially available product acceptable to manufacturer.

b. Coordinate selection of floor polish with Government's maintenance service.

2. Cover products installed on horizontal surfaces with undyed, untreated building paper until Substantial Completion.

3. Do not move heavy and sharp objects directly over surfaces. Place hardboard or plywood panels over flooring and under objects while they are being moved. Slide or roll objects over panels without moving panels.

END OF SECTION 09651

PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section includes the following:
1. Vinyl composition tile (VCT).
2. Resilient wall base and accessories.
1.3 SUBMITTALS
A. Product Data: For each type of product indicated.
B. Samples for Initial Selection: For each type of product indicated.
C. Samples for Verification: Full-size units of each color and pattern of resilient floor tile required.
1. Resilient Wall Base and Accessories: Manufacturer's standard-size Samples, but not less than 1T12 inches1T5T (300 mm)5T long, of each resilient product color and pattern required.

D. Maintenance Data: For resilient products to include in maintenance manuals.

1.4 DELIVERY, STORAGE, AND HANDLING
A. Store resilient products and installation materials in dry spaces protected from the weather, with ambient temperatures maintained within range recommended by manufacturer, but not less than 1T50 deg F1T5T (10 deg C)5T or more than 1T90 deg F1T5T (...
1.5 PROJECT CONDITIONS
A. Maintain temperatures within range recommended by manufacturer, but not less than 1T70 deg F1T5T (21 deg C)5T or more than 1T95 deg F1T5T (35 deg C)5T, in spaces to receive floor tile during the following time periods:
1. 48 hours before installation.
2. During installation.
3. 48 hours after installation.
B. After postinstallation period, maintain temperatures within range recommended by manufacturer, but not less than 1T55 deg F1T5T (13 deg C)5T or more than 1T95 deg F1T5T (35 deg C)5T.
C. Close spaces to traffic during floor covering installation.
D. Close spaces to traffic for 48 hours after floor covering installation.
E. Install resilient products after other finishing operations, including painting, have been completed.
1.6 EXTRA MATERIALS
A. Furnish extra materials described below that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
1. Floor Tile: Furnish 1 box for every 50 boxes or fraction thereof, of each type, color, and pattern of floor tile installed.
2. Resilient Wall Base and Accessories: Furnish not less than 1T10 linear feet1T5T (3 linear m)5T for every 1T500 linear feet1T5T (150 linear m)5T or fraction thereof, of each type, color, pattern, and size of resilient product installed.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the products listed in other Part 2 articles.
2.2 COLORS AND PATTERNS
A. Colors and Patterns: As selected from manufacturer's full range.
2.3 VINYL COMPOSITION TILE
A. Vinyl Composition Tile (VCT): ASTM F 1066.
1. Armstrong World Industries, Inc.
2. Azrock Commercial Flooring, DOMCO.
3. Congoleum Corporation.
4. Mannington Mills, Inc..
5. Tarkett Inc.
B. Wearing Surface: Smooth.
C. Thickness: 1T0.125 inch1T5T (3.2 mm)5T.
D. Size: 1T12 by 12 inches1T5T (305 by 305 mm)5T.
E. Fire-Test-Response Characteristics:
1. Critical Radiant Flux Classification: Class I, not less than 0.45 W/sq. cm per ASTM E 648.
2.4 RESILIENT WALL BASE
A. Wall Base: Product complying with FS SS-W-40, Type II and with requirements specified in Resilient Tile Flooring Schedule on the Drawings. Color and pattern in accordance with Schedule.
1. Armstrong World Industries, Inc.
2. Azrock Commercial Flooring, DOMCO.
3. Burke Mercer Flooring Products.
4. Johnsonite.
5. Roppe Corporation.
B. Minimum Thickness: 1T0.125 inch1T5T (3.2 mm)5T.
C. Height: 1T4 inches1T5T (102 mm)5T.
D. Lengths: Cut lengths 1T48 inches1T5T (1219 mm)5T long or coils in manufacturer's standard length.
E. Outside Corners: Premolded.
F. Inside Corners: Job formed.
G. Surface: Smooth.
2.5 RESILIENT MOLDING ACCESSORIES
A. Description: [Cap for cove carpet] [Cap for cove resilient sheet floor covering] [Carpet bar for tackless installations] [Carpet edge for glue-down applications] [Nosing for carpet] [Reducer strip for resilient floor covering] [Joiner for tile and...
1. Burke Mercer Flooring Products.
2. Johnsonite.
3. Marley Flexco (USA), Inc.
4. Roppe Corporation.
5. Stoler Industries.
B. Material: Vinyl.
C. Profile and Dimensions: As indicated.
2.6 INSTALLATION MATERIALS
A. Trowelable Leveling and Patching Compounds: Latex-modified, portland cement based or blended hydraulic cement based formulation provided or approved by resilient product manufacturer for applications indicated.
B. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated.
C. Metal Edge Strips: Extruded aluminum with mill finish of width shown, of height required to protect exposed edges of tiles, and in maximum available lengths to minimize running joints.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, with Installer present, for compliance with requirements for installation tolerances, moisture content, and other conditions affecting performance.
1. Verify that finishes of substrates comply with tolerances and other requirements specified in other Sections and that substrates are free of cracks, ridges, depressions, scale, and foreign deposits that might interfere with adhesion of resilient pr...
2. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Prepare substrates according to manufacturer's written recommendations to ensure adhesion of resilient products.
B. Concrete Substrates: Prepare according to ASTM F 710.
1. Verify that substrates are dry and free of curing compounds, sealers, and hardeners.
2. Alkalinity and Adhesion Testing: Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing.
3. Moisture Testing:
a. Perform anhydrous calcium chloride test, ASTM F 1869. Proceed with installation only after substrates have maximum moisture-vapor-emission rate of 1T3 lb of water/1000 sq. ft.1T5T (1.36 kg of water/92.9 sq. m)5T in 24 hours.
b. Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing.
C. Remove substrate coatings and other substances that are incompatible with adhesives and that contain soap, wax, oil, or silicone, using mechanical methods recommended by manufacturer. Do not use solvents.
D. Use trowelable leveling and patching compound to fill cracks, holes, and depressions in substrates.
E. Move resilient products and installation materials into spaces where they will be installed at least 48 hours in advance of installation.
1. Do not install resilient products until they are same temperature as space where they are to be installed.

F. Sweep and vacuum clean substrates to be covered by resilient products immediately before installation. After cleaning, examine substrates for moisture, alkaline salts, carbonation, and dust. Proceed with installation only after unsatisfactory con...

3.3 TILE INSTALLATION
A. Lay out tiles from center marks established with principal walls, discounting minor offsets, so tiles at opposite edges of room are of equal width. Adjust as necessary to avoid using cut widths that equal less than one-half tile at perimeter.
1. Lay tiles in patterns indicated.
B. Match tiles for color and pattern by selecting tiles from cartons in the same sequence as manufactured and packaged, if so numbered. Discard broken, cracked, chipped, or deformed tiles.
1. Lay tiles in pattern of colors and sizes indicated.
C. Scribe, cut, and fit tiles to butt neatly and tightly to vertical surfaces and permanent fixtures including built-in furniture, cabinets, pipes, outlets, edgings, door frames, thresholds, and nosings.
D. Extend tiles into toe spaces, door reveals, closets, and similar openings.
E. Maintain reference markers, holes, and openings that are in place or marked for future cutting by repeating on floor tiles as marked on substrates. Use chalk or other nonpermanent, nonstaining marking device.
F. Install tiles on covers for telephone and electrical ducts and similar items in finished floor areas. Maintain overall continuity of color and pattern with pieces of tile installed on covers. Tightly adhere tile edges to substrates that abut cove...
G. Adhere tiles to flooring substrates using a full spread of adhesive applied to substrate to produce a completed installation without open cracks, voids, raising and puckering at joints, telegraphing of adhesive spreader marks, and other surface imp...
3.4 RESILIENT WALL BASE INSTALLATION
A. Apply wall base to walls, columns, pilasters, casework and cabinets in toe spaces, and other permanent fixtures in rooms and areas where base is required.
B. Install wall base in lengths as long as practicable without gaps at seams and with tops of adjacent pieces aligned.
C. Tightly adhere wall base to substrate throughout length of each piece, with base in continuous contact with horizontal and vertical substrates.
D. Do not stretch wall base during installation.
E. On masonry surfaces or other similar irregular substrates, fill voids along top edge of wall base with manufacturer's recommended adhesive filler material.
F. Premolded Corners: Install premolded corners before installing straight pieces.
G. Job-Formed Corners:
1. Inside Corners: Use straight pieces of maximum lengths possible. Form by cutting an inverted V-shaped notch in toe of wall base at the point where corner is formed. Shave back of base where necessary to produce a snug fit to substrate.
3.5 CLEANING AND PROTECTION
A. Perform the following operations immediately after completing resilient product installation:
1. Remove adhesive and other blemishes from exposed surfaces.
2. Sweep and vacuum surfaces thoroughly.
3. Damp-mop surfaces to remove marks and soil.
a. Do not wash surfaces until after time period recommended by manufacturer.
B. Protect resilient products from mars, marks, indentations, and other damage from construction operations and placement of equipment and fixtures during remainder of construction period. Use protection methods recommended in writing by manufacturer.
1. Apply protective floor polish to horizontal surfaces that are free from soil, visible adhesive, and surface blemishes if recommended in writing by manufacturer.
a. Use commercially available product acceptable to manufacturer.
b. Coordinate selection of floor polish with Government's maintenance service.
2. Cover products installed on horizontal surfaces with undyed, untreated building paper until Substantial Completion.
3. Do not move heavy and sharp objects directly over surfaces. Place hardboard or plywood panels over flooring and under objects while they are being moved. Slide or roll objects over panels without moving panels.

File details come from the government source that posted it. Updated .