This document is an architectural floor plan for a military facility. The plan displays a detailed layout of the Directorate of Military Facilities Engineering building for the State of Maine, showing multiple levels with comprehensive dimensional annotations and spatial organization. The drawing includes grid references (numbered 1-18 horizontally and lettered A-S vertically) that define the structural bay system and room locations throughout the building.

The floor plan depicts numerous interior spaces with precise measurements in feet and inches, indicating room sizes, corridor widths, and structural elements. Various functional areas are delineated throughout the layout, including what appear to be office spaces, meeting areas, mechanical rooms, and circulation corridors. The plan incorporates architectural symbols for doors, walls, stairs, and other building components. The document includes a title block in the lower right corner referencing camp information and drawing specifications, with a State of Maine seal visible. This appears to be a working construction or facilities management document used for building administration, space planning, and maintenance purposes.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6'

-4

5/

8"

233'-6"

7'

-5

1.8

AA

J

N

B

4.4

Q

5 7

10 12 15

DD

FF

GG

KK

LL

PP

R

S

K.5

J.5

5.9

M

C C

Q.2

R.3

H

15.5

11'-8" 24'-0" 26'-5" 18'-3" 24'-0" 24'-0" 24'-0" 20'-4" 26'-0" 32'-0" 30'-4"

'-0

'-8

'-4

'-0

'-0

'-0

8' -4

'-8

'-0

'-0

7' -4

88'-3 1/2" 30'-4"

9'-8" 18'-8" 26'-0" 32'-0" 30'-4"24'-0" 21'-4" 21'-4" 21'-4"32'-4" 24'-0"

'-0

'-2

/2

7' -4

'-8

'-0

'-0

'-4

'-0

'-0

'-8

8' -4

'-0

9.2

'-4

12.2

8'-4" 24'-0" 3'-3" 20'-9" 8"

7 1/2"

8'-4 1/2" 13'-0" 13'-0"

'-8

A.7A.7

K.8

4' -3

'-9

'-0

'-0

'-0

12.1

7' -4

'-8

8'-5" 18'-0" 3'-0" 21'-0"

'-8

'-8

14'-2"

'-3

" 13'-7" 13'-6"

'-2

1 2" 16'-3"

'-6

1 2"

'-8

14'-01 2"

11'-8" 11'-7" 13'-8"

'-6

1 2"

'-6

1 2"

'-6

1 2"

'-6

1 2"

'-6

1 2"

'-6

1 2"

'-6

1 2"

13'-8" 11'-6" 15'-71 2" 12'-101

2"

23'-11 2"

9' -5

7'

6' -1

1 2"

'-4

1 2"

10'-11 2"

'-4

1 2"

'-4

1 2"

16'-7"

17'

7' -1

1"

11'-61 2"

'-0

1 2"

14'-1" 14'-11"

8' -1

1"

8' -6

6'-91 2"

'-0

1 2"

35'-5"

'-8

25'-6"

'-9

12'-1"

17'-4"

'-7

'-8 1 2"

17'-21 2"

'-0

1 2"

17'-21 2"

42'-2"

'-1

01 2"

8' -6

1 2"

13'-2"

'-1

0"

10' 5'

22'-6" 12 '-4

1 2"

'-3

1 2"

7'-11"

6'-4"

5' -1

1 2"

26'-8"

7' -5

1 2" 43'-10"

'-5

1 2"

'-6

11'-7"

'-6

27'-61 2"

'-6

1 2"

31'-8"

'-0

1 2" 11'-7"

'-5

1 2"

11'-101 2"

'-5

1 2"

12'-1"

8' -5

6'-71 2"

10'-9"

'-0

1 2"

6'-01 2"

5' 56'-01 2"

7' -1

1"

9'

8' -2

1 2"

9' -2

13' 9' -2

1 2"

25'-7"

9' -5

1 2"

13' 12'-3" 9' -5

1 2"

9' -5

1 2"

12'-10"

8' -6

" 8'-101 2"

'-3

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

17'-01 2"

'-4

1 2"

'-8

'-8

'-9

1 2"

50'-7"

4'-111 2"

5' -4

'-1

0"

9' -1

01 2"9'-21 2"12'-7"

9' -8

"12'-3"

9' -8

1 2"13'

9' -8

1 2"

45'-7"

5' -3

1 2"

'-6

" 8'-11"

'-7

" 14'-8"

'-7

" 14'-7"

'-6

1 2"8'-10"

13'-11"

5' -8

1 2"

'-6

'-7

'-7

13'-71 2"

19'-51 2"

'-8

"19'-7"

'-8

30'-101 2"

5' -8

84'-11 2"

7' -9

1 2"67'-1" 7'

-6

'-9

1 2"24 '-0

1 2"

5'-61 2"

'-1

01 2" 14'-01 2"

'-8

" 10'-6" 13'-61

2"

'-7

7'-5" 9'-1"

'-1

11 2"

'-1

1"

'-1

11 2" 13'-101

2"

13'-101 2"

'-4

14'-9"

8' -6

'-7

10'-71 2"

'-8

13'-11" 14'-01

2"

14'-01 2"

14'-01 2"

14'-01 2"

'-9

9' -8

13'-8" 13'-81 2"

'-6

'-2

5'

'-7

13'-101 2"

19'-5"

9' -7

14'-01 2"

14'-01 2"

14'-01 2"

14'-01 2"

9' -0

1 2"

'-4

'-4

'-3

'-1

1"

'-7

'-1

11 2"

52'-111 2"

69'-81 2"

67'-6" 7' -3

1 2"

22'-1"

'-9

1'

-3

6'-101 2"

32'-4"

'-7

" 22 '-7

1 2"

7'-6"

'-5

1 2"

14'-31 2"

'-7

'-8

'-6

9' -7

1 2"

9' -0

1 2"

11'-61 2"11'-71

2"

9' -1

"22'-01 2"

22'-9"

'-2

'-1

0"

7'-8"

8' -9

1 2" 7'

19'-3"

'-7

" 11'-11"

'-7

10'-9"

7' -2

7'10'-81 2"

'-8

23'-11"

24'-31 2" 7'

-1 01 2"

'-4

5'

'-7

"9'-81 2"9'-7"

'-7

9'-7"

'-7

13'-11"

'-7

9'-7"

'-8

1 2"

20'

'-2

'-7

9'-6"

17'-3"11 '-1

01 2"

'-1

9'-61 2" 9'-7"

'-8

'-7

" 9'-7"

'-6

'-7

'-4

'-1 0"

9' -7

1 2" 9'-7"

9'-7"

9'-61 2"

9'-7"

'-1

9'-61 2"

'-1

9'-2"

9'-21 2"

6' -1

0"

6' -0

1 2"9'-7"

'-6

14'-31 2"

'-5

'-3

6'-71 2"

52'-10" 6' -0

1 2"

'-1

14'-101

2"

'-5

21'-01 2"

'-1

7'-8" 6'

-1

'-2

1 2"

D

I R EC T ORA T E

M

I L I TARY BUREAU

FA

C

I L

IT

IES ENG INEER

I NG

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text

OF

AutoCAD SHX Text

DEPARTMENT OF DEFENSE, VETERANS

AutoCAD SHX Text

DIRECTORATE OF FACILITIES ENGINEERING

AutoCAD SHX Text

STATE OF MAINE

AutoCAD SHX Text

AND EMERGENCY MANAGEMENT

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJECT:

AutoCAD SHX Text

LOCATION:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

FACILITY - ASSET

AutoCAD SHX Text

SHEET NO:

AutoCAD SHX Text Description of Revision

AutoCAD SHX Text Date

AutoCAD SHX Text DFE Project #

AutoCAD SHX Text Rev#

AutoCAD SHX Text

JOINT FORCE HEADQUARTERS

AutoCAD SHX Text

OVERALL SECOND FLOOR PLAN

AutoCAD SHX Text

CAMP CHMBRLN. AUGUSTA, MAINE

AutoCAD SHX Text

KES

AutoCAD SHX Text

KES

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 12/08/2021

AutoCAD SHX Text 23956

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AS-BUILT INFORMATION

AutoCAD SHX Text 230113

AutoCAD SHX Text 12-08/2021

AutoCAD SHX Text

AutoCAD SHX Text

UPDATED TO 6.2 A/E/C CAD STANDARDS

AutoCAD SHX Text

KES

AutoCAD SHX Text 06/10/2025

Sheets and Views
Building Layout

File details come from the government source that posted it. Updated .