LIMITED HAZARDOUS

MATERIALS SURVEY

REPORT

Jet Engine Repair Shop – B3416 Hawaii Air National Guard

Joint Base Pearl Harbor Hickam Pearl Harbor, Hawaii

Prepared for:

Burns & McDonnell Engineering Co., Inc.

9400 Ward Parkway Kansas City, Missouri 64114

Report Date: October 29, 2012

Prepared By:

677 Ala Moana Blvd., Suite 920

Honolulu, HI 96813

TRC Project: 198110

TABLE OF CONTENTS

EXECUTIVE SUMMARY ................................................................................................................... i

INTRODUCTION

BACKGROUND

Asbestos Containing Materials

Asbestos Sampling Procedures

Paint Chip Sampling

Laboratory Analysis

Suspect PCB Containing Equipment

Mercury Containing Fluorescent Light Tubes and Thermostats

FINDINGS

Asbestos Containing Materials (>1% Asbestos)

Negative Materials (No Asbestos Detected)

Paint Chip Sampling Results

Suspect PCB Containing Equipment

Mercury Containing Fluorescent Lights and Thermostats

RECOMMENDATIONS

Asbestos Containing Materials

Lead Containing Paints

Suspect PCB Containing Light Ballasts and Electrical Transformers

Mercury Containing Fluorescent Lights and Thermostats

DISCLAIMER

Appendices

Appendix A – Sample Location Diagrams

Appendix B – Asbestos Containing Material Diagrams

Appendix C – Laboratory Results and Chain of Custody

Appendix D – Certifications

Limited Hazardous Materials Survey Report October 29, 2012 Hawaii Air National Guard – B3416, Pearl Harbor, HI TRC Project: 198110

- i -

EXECUTIVE SUMMARY

TRC Environmental Corporation (TRC) was contracted by Burns & McDonnell Engineering Co., Inc. to conduct a limited scope hazardous materials survey at the Hawaii Air National Guard Jet Engine Repair Shop, Building B3416, located at the Joint Base Pearl Harbor Hickam, Pearl Harbor, Hawaii. The limited hazardous materials survey included an interior and exterior asbestos survey, inspection and sampling for lead containing paints, identification of suspect poly chlorinated biphenyl (PCB) containing equipment and identification of suspect mercury containing equipment.

Building 3416 is a two story, metal structure with metal roof which was reportedly built in 1976 and contains approximately 32,080 square feet of floor space. TRC understands building B3416 is used by the Hawaii Air National Guard for the repair of jet engines. The inspection was performed on October 17 and 18, 2012, by Mr. K. Heath Howard (HIASB-2836), Asbestos Hazard Emergency Response Act (AHERA) certified Asbestos Building Inspector and Hawaii Lead Risk Assessor (PB-0438).

Asbestos-Containing Materials

Results of analysis confirmed asbestos was identified within some of the bulk samples collected.

Any materials uncovered during renovation or demolition activities that are not addressed in this inspection report, or presumed asbestos containing materials (PACM), must be sampled by an accredited asbestos inspector prior to any disturbance, or they must be treated as asbestos containing (ACM). Please note that TRC was unable to fully inspect the Northwest Carpeted Areas on the Second Floor due to restricted access.

Material Location Percentage/

Type Approx.

Quantity

Condition Material

Type

NESHAP

Category

First Floor Black

Mastic Bearing Room 4% Chrysotile 178 SF Good Misc. Cat I

Residual Black

Mastic

Contractor’s Room

5% Chrysotile 450 SF Good Misc. Cat I

Black Mirror Mastic

Gym 20%

Chrysotile 320 SF Good Misc. Cat I

Second Floor

Black Mastic

Southeast Offices, Break

Room, Southeast Hallway

(Under 2nd Layer Tile)

4% Chrysotile 5,710 SF Good Misc. Cat I

12” White with Tan Specks Vinyl

Floor Tile

Training Class Room, Plans &

Scheduling, Women’s Shower

2% Chrysotile 1134 SF Good Misc. Cat I

- ii -

Lead-Containing Paints

Results of laboratory analysis indicate that lead was detected in some of the paint chip samples that were collected and analyzed.

Sample Number

Location Description % Lead

(by weight)

Pb-1 Fan Repair Ceiling Cream Interior Paint 0.029

Pb-2 Southwest Exterior Wall

Conduit Cream Exterior Paint

<0.010

Pb-3 Courtyard Southwest

Corner Light Brown Exterior

Paint

0.084

Pb-4 Floor 1 Contractor Room

Door Dark Tan Interior

Door Paint

<0.010

Pb-5 Southeast Exterior

Staircase Dark Brown Exterior

Rail Paint 0.058

Pb-6 Center Roof White Roof Paint <0.010

Pb-7 Server Room Door Yellow / Brown Interior Paint

<0.010

Pb-8 Floor 2 Northwest

Hallway White Interior Paint <0.010

Pb-9 Floor 2 Northwest

Hallway South Steel Column

Brown over Orange Paint on Structural

Steel 0.031

Suspect Polychlorinated Biphenyl Containing Equipment

Based on the limited visual inspection, suspect PCB containing equipment was identified at the property.

Fluorescent Light Ballasts Electrical Transformers

317 2

- iii -

Mercury Containing Fluorescent Lights and Thermostats

Based on the limited visual inspection, suspect mercury containing equipment was identified at the property.

Fluorescent Light Tubes

HID Lamps Thermostats

912 45 3

INTRODUCTION

A limited hazardous materials survey was conducted by TRC at the Hawaii Air National Guard Jet Engine Repair Shop Building, B3416, located at Joint Base Pearl Harbor Hickam. Building 3416 is a two story, metal structure with metal roof which was reportedly built in 1976 and contains approximately 32,080 square feet of floor space. TRC understands building B3416 is used by the Hawaii Air National Guard for the repair of jet engines.

The limited hazardous materials survey included an interior and exterior asbestos survey, inspection and sampling for lead containing paints, identification of suspect poly chlorinated biphenyl (PCB) containing equipment and identification of suspect mercury containing equipment. Mr. K. Heath Howard (HIASB-2836), AHERA certified Asbestos Building Inspector and Hawaii Lead Risk Assessor (PB-0438), conducted the inspections and sampling activities on October 17 and 18, 2012. Please note that TRC was unable to fully inspect the Northwest Carpeted Areas on the Second Floor due to restricted access.

BACKGROUND

Asbestos Containing Materials

The Occupational Safety and Health Administration (OSHA), the Environmental Protection Agency (EPA) and the State of Hawaii Department of Health (DOH) define an asbestos-containing material (ACM) as any material containing more than one percent (>1.0%) asbestos by weight. In addition, ACM are designated as:

Friable asbestos - material which can be crumbled, pulverized or reduced to powder by hand pressure, a.k.a. Regulated Asbestos Containing Materials (RACM).

Category I Non-friable - includes resilient floor coverings, asphalt roofing products, gaskets and packing.

Category II Non-friable - any non-friable ACM that is not in Category I (i.e. Asbestos-cement (Transite) siding or roofing material).

Asbestos Sampling Procedures

The survey was conducted in accordance with the sample collection protocols established in 40 CFR 763 (AHERA), 40 CFR 61 Subpart M (NESHAP) and HAR 11:501-504 (Hawaii asbestos rules). A summary of survey activities is provided below.

Survey activities began with visual observation of the exterior and interior areas of the areas of the building to identify homogeneous areas of suspect ACM. A homogeneous area consists of building materials that appear similar throughout in terms of color and texture that does not extend to other buildings or floors. Visual assessments were conducted in accessible areas of the building. Building materials identified as glass, wood, masonry or metal were not considered suspect ACM.

A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. Friability was assessed by physically touching suspect materials.

Based on results of the visual observation, bulk samples of suspect ACM were collected in accordance with State of Hawaii Department of Health (DOH) sampling protocols. Samples of suspect materials were collected in each homogeneous area. Bulk samples were collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker. One-hundred and eight (108) bulk samples were collected from building B3416.

All asbestos bulk samples were submitted under proper COC documentation to the laboratory.

Bulk samples were analyzed by PLM utilizing the EPA’s, Method for the Determination of Asbestos in Bulk Building Materials, EPA 600/M4-82-020. Analysis by PLM was performed by visual observation of the bulk sample and slides prepared of the bulk sample for microscopic examination and identification. The samples were analyzed for asbestos (Chrysotile, Amosite, Crocidolite, Anthophyllite, and Actinolite/Tremolite), fibrous non-asbestos constituents (mineral wool, cellulose, etc.) and non-fibrous constituents. Using a stereoscope, the microscopist visually estimated the relative amounts of each constituent by determining the estimated area of the asbestos compared with the area estimate of the total sample.

Paint Chip Sampling

Paint chip samples were collected from painted surfaces to determine total lead content and assist in determining Occupational Safety and Health Administration (OSHA) requirements with respect to construction activities which may disturb lead-containing paints. Nine (9) paint chip samples were collected from building B3416.

All paint chip samples were submitted under proper COC documentation to the laboratory.

Samples were analyzed by Flame AAS utilizing the Environmental Protection Agency’s (EPA) Test Method for Evaluating Solid Waste, Physical / Chemical Methods, EPA SW-846 Method 7420.

Laboratory Analysis

Laboratory services were provided by LA Testing, a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory (NVLAP code #200232-0) and an Environmental Lead Laboratory Accreditation Program (ELLAP) certified laboratory (ELLAP #102814), located in South Pasadena, California.

Suspect PCB Containing Equipment

TRC identified the approximate number of fluorescent light ballasts and electrical transformers in the building as part of the hazardous materials survey. TRC’s inspection did not include a determination as to whether the light ballasts or electrical transformers are in fact PCB containing.

Mercury Containing Fluorescent Light Tubes and Thermostats

TRC identified the approximate number of fluorescent light tubes and thermostats in the building as part of the hazardous materials survey. TRC’s inspection did not include a determination as to whether the fluorescent lights and thermostats are in fact mercury containing.

FINDINGS

Asbestos Containing Materials (>1% Asbestos)

Laboratory analytical results indicated the following materials were positive for asbestos in concentrations greater than 1%:

Percentage/

Type Approx.

Quantity

Condition Material

Type

NESHAP

Category

First Floor Black

Mastic Bearing Room 4% Chrysotile 178 SF Good Misc. Cat I

Residual Black

Mastic

Contractor’s Room

5% Chrysotile 450 SF Good Misc. Cat I

Black Mirror Mastic

Gym 20%

Chrysotile 320 SF Good Misc. Cat I

Second Floor

Black Mastic

Southeast Offices, Break

Room, Southeast Hallway

(Under 2nd Layer Tile)

4% Chrysotile 5,710 SF Good Misc. Cat I

12” White with Tan Specks Vinyl

Floor Tile

Training Class Room, Plans &

Scheduling, Women’s Shower

2% Chrysotile 1134 SF Good Misc. Cat I

Negative Materials (No Asbestos Detected)

Samples of the following suspect materials were collected in the following locations and were found to be negative for asbestos following laboratory analysis:

First Floor

White Drywall and Joint Compounds Gym, Packing & Crating, Contractor Room, Packing & Crating Offices

White 2’ x 4’ Wormhole Drop Ceiling Tile Gym, Packing & Crating Offices Blue Vinyl Cove Base with Tan Glue Gym

Black Waterproofing Paper Exterior Corrugated Metal Walls Cream CMU Block and Mortar Perimeter Walls, Fan Prep Area, Nozzle Repair, Packing & Crating, Break Room, Restrooms, Engine Inspection and Repair, Welding, Packing & Crating Offices Brown / Gray Plaster on Lathe Courtyard South Entry Columns, Fan Prep

Area Columns, East Exterior Wall Columns, West Exterior Wall Columns

Gray Concrete Slab Throughout Slab

White Drywall and Joint Compound Fan Prep Area, Nozzle Repair, Break Room, Restrooms, Welding Room, Center Offices

White 2’ x 4’ Pinhole Drop Ceiling Tile Contractor’s Room, Contractor’s Office Black Vinyl Cove Base with Beige Glue Contractor’s Room, Welding Office, Bearing

Room, Contractor’s Office, Packing & Crating Office

12” Tan with Specks Vinyl Floor Tile with Yellow Glue

(Please note residual black mastic in the

Contractor’s Room is ACM.)

Contractor’s Room, Contractor’s Office

12” Blue with Specks Vinyl Floor Tile with Yellow Glue

Room 107

12” White with Brown Specks Vinyl Floor Tile

(Please note the associated black mastic is

ACM.)

Bearing Room

12” Brown Faux Wood Vinyl Floor Tile and Black Mastic

Packing & Crating Offices Including Carpeted Area

Gray Window Caulking Courtyard, South Exterior Wall, East Exterior Wall

Black Window Caulking West Exterior Wall Gray HVAC Mastic West Mechanical Equipment

Beige Plaster Skim Coat Contractor’s Office Black Waterproofing West Shed Corrugated Metal Walls Yellow Carpet Glue Packing & Crating South Office

Tan Glue with Residual Black Mastic Gym Second Floor

12” Brown Faux Marble Vinyl Floor Tile with Brown / Clear Glue

(Please note the associated black mastic on the 2nd layer floor tile is ACM.)

Southeast Hallway, Southeast Offices

Black Vinyl Cove Base with Tan / Brown Glue

Throughout Floor 2 Southeast Areas

White Drywall and Joint Compound Throughout Floor 2 12” Tan with Specks Vinyl Floor Tile and

Orange Glue Northwest Hallway, Training, Testing, Testing

Storage

Please note that TRC was unable to fully inspect the Northwest Carpeted Areas on the

Second Floor due to restricted access.

2’ x 4’ Tan / White Wormhole Drop Ceiling

Tile Southeast Offices

Yellow Carpet Glue Throughout Carpeted Areas

2nd Layer Beige Vinyl Floor Tile

(Please note that the associated black mastic is ACM.)

Southeast Offices, Break Room, Southeast Hallway

Brown Vinyl Cove Base and Brown Glue Northeast Offices, Northeast Hallway, Server Room, Bathroom Utility Closet

Black Mastic

(Please note that the associated 12” white with specks vinyl floor tile is ACM.)

Training Classroom, Plans & Scheduling, Women’s Shower

12” White Wall Acoustic Tile MXOP, Server Room White TSI Wrap Throughout Above Drop Ceiling

White Window Caulk Break Room Windows Roof

White Penetration Mastic Roof Penetrations

Paint Chip Sampling Results

Sample Number

Location Description % Lead

(by weight)

Pb-1 Fan Repair Ceiling Cream Interior Paint 0.029

Pb-2 Southwest Exterior Wall

Conduit Cream Exterior Paint

<0.010

Pb-3 Courtyard Southwest

Corner Light Brown Exterior

Paint

0.084

Pb-4 Floor 1 Contractor Room

Door Dark Tan Interior

Door Paint

<0.010

Pb-5 Southeast Exterior

Staircase Dark Brown Exterior

Rail Paint 0.058

Pb-6 Center Roof White Roof Paint <0.010

Pb-7 Server Room Door Yellow / Brown Interior Paint

<0.010

Pb-8 Floor 2 Northwest

Hallway White Interior Paint <0.010

Pb-9 Floor 2 Northwest

Hallway South Steel Column

Brown over Orange Paint on Structural

Steel 0.031

Lead was detected above the detection limit in samples 1, 3, 5, and 9.

Suspect PCB Containing Equipment

Fluorescent Light Ballasts Electrical Transformers

317 2

Three hundred seventeen fluorescent light ballasts and two pad mounted electrical transformers were identified in B3416.

Fluorescent Light Tubes

HID Lamps Thermostats

912 45 3

Nine-hundred twelve fluorescent light tubes, forty-five High-Intensity Lamps (HID) and three thermostats were identified in B3416.

RECOMMENDATIONS

Asbestos Containing Materials

Results of laboratory analysis confirmed asbestos was identified within some of the bulk samples collected. The asbestos-containing materials were found to be in good condition at the time of the inspection. Removal of asbestos-containing materials should be performed by a State of Hawaii licensed asbestos abatement contractor, and should be handled, stored, and disposed of according to all local, state, and federal regulations.

Any materials uncovered during renovation or demolition activities that are not addressed in this inspection report, or presumed asbestos containing materials (PACM), must be sampled by an accredited asbestos inspector prior to any disturbance, or they must be treated as asbestos containing (ACM).

Lead Containing Paints

Results of laboratory analysis confirmed that lead was detected in some of the paint chip samples collected. TRC recommends that any demolition or renovation activities which may disturb painted surfaces be conducted according to the OSHA requirements regarding lead in construction (29 CFR 1926.62).

Suspect PCB Containing Light Ballasts and Electrical Transformers

Suspect PCB containing fluorescent light ballasts and pad mounted electrical transformers were identified in B3416. Fluorescent ballasts manufactured prior to January 1, 1978 or ballasts that are not labeled “No PCBs” must be considered PCB containing unless testing proves otherwise.

The two pad mounted electrical transformers should be assumed to be PCB containing until proven otherwise.

Mercury containing fluorescent light tubes and suspect mercury containing thermostats were identified in B3416. Fluorescent light tubes and thermostats that are scheduled for disposal must be managed according to applicable local, state and federal waste disposal regulations.

DISCLAIMER

The content presented in this report is based on data collected during the site inspection and survey, review of pertinent regulations, requirements, guidelines and commonly followed industry standards, and information provided by Client, their clients, agents, and representatives.

The work has been conducted in an objective and unbiased manner and in accordance with generally accepted professional practice for this type of work. TRC believes the data and analysis to be accurate and relevant, but cannot accept responsibility for the accuracy or completeness of available documentation or possible withholding of information of other parties.

This limited hazardous materials survey report is designed to aid the property owner, architect, construction manager, general contractor, and asbestos abatement contractor in locating asbestos containing materials, lead containing paints, suspect PCB containing equipment and suspect mercury containing equipment.

Sincerely, TRC Environmental Corporation

K. Heath Howard Bart Ashley, CIH, CSP Industrial Hygienist Senior Project Manager

Appendix A – Sample Location Diagrams

FA B C D E G I J K L

WOMENS

LATRINE

CONTRACTOR

MENS

LATRINE

BREAKROOMNOZZLE

REPAIR

FAN REPAIR

PARTS

STORAGE

PACKING &

CRATING

PACKING &

CRATING

WELDING

SHOP

SUPER

MEN'S

LOCKER

MEN'S

LATRINE

MACHINE SHOP

WELDING

SUPER

OFFICE

MECH

ROOM

CONTRACTOR'S

OFFICE

BEARING

ROOM

PARTS

CLEANING

HALLWAY

AIRCRAFT ENGINE

INSPECTION &

REPAIR SHOP

COURT - YARD

ELEV

TOOL CRIB

S c a le

F o r M ic ro fi lm in g

In c h e s

M ill im e te rs

191 1615141312111098765432 17 18

N

M

L

K

J

I

H

G

F

E

D

C

B

A date detailed checkeddesigned ofsheet sheets project contract rev.drawing fileC O

P Y

R

IG

H T

B U

R N

S A

N D

M cD

O N

N E

LL

E

N G

IN

E

E R

IN

G

C O

M P

A N

Y , I

N C

C

HAWAII AIR NATIONAL GUARD

JOINT BASE PEARL HARBOR - HICKAM

OAHU, HAWAII

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

68331

Project No. - KNMD069212

JANUARY 2012

W90FYQ-09-D-0002

REPAIR JET ENGINE SHOP

B3416

68331 EXISTING 1ST FLR.DWG

B. AMES

L. COLE J. WIEDERHOLT

60960 [200'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[1

'-0

[1

8' -4

[2

3' -4

[1

8' -4

[2

7' -0

[3 8'

-0

EXISTING FIRST FLOOR PLAN

FLOOR 1 SAMPLE

LOCATION

DIAGRAM

1-A

1-B

1-C

2-A

2-B

2-C

3-A - 3-C

4-A - 4-C 5-A

5-B

5-C

6-A

6-B 6-C

7-A

7-B

7-C

8-A

8-B

8-C

9-A

9-B

9-C

10-A - 10-C

11-A - 11-B

11-C

12-A

12-B - 12-C

13-A - 13-C

14-A

14-B

14-C

15-A

15-B

15-C

16-A - 16-C

17-A - 17-C

25-A - 25-C

26-A - 26-C

27-A 27-C

28-A - 28-C

Pb-1

Pb-2

Pb-3 Pb-4

Pb-5

32-A 32-B - 32-C

33-A - 33-C

VICE

MXG

AMXS

COMMANDER

MXG

XO

MXG

COMMANDER

CONFERENCE

ROOM

CONTRACTOR

OFFICE MOF

CHIEF

CSS

WOMEN'S

LATRINE

MEN'S

LATRINE

WATER

HEATER

JAN

LOCKER

ROOM

M A

IN

TE

N A

N C

E O

FF

IC

E R

MAINTENANCE

CONTROL

COMPUTER

ROOM

STORAGE

CLOSET

UPPER PORTION OF

AIRCRAFT ENGINE

INSPECTION &

REPAIR SHOP

TRAINING

COURT - YARD

BELOW

UPPER PORTION OF

PYLON M.E.R. & T.E.R.

STORAGE

CSS

NCOIC

OFFICE

TRAINING

CLASSROOM

A/V-STORAGE

ROOM

PLANS &

SCHEDULING

MXOP

TESTING

STORAGE

TESTING

UNISEX

LATRINE

LOCKER

ROOM

CSS

NCOIC

OFFICE

ELEV

S c a le

F o r M ic ro fi lm in g

In c h e s

M ill im e te rs

191 1615141312111098765432 17 18

N

M

L

K

J

I

H

G

F

E

D

C

B

A date detailed checkeddesigned ofsheet sheets project contract rev.drawing fileC O

P Y

R

IG

B U

R N

S A

N D

M cD

O N

N E

LL

E

N G

IN

E

E R

IN

G

C O

M P

A N

Y , I

N C

C

HAWAII AIR NATIONAL GUARD

JOINT BASE PEARL HARBOR - HICKAM

OAHU, HAWAII

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

68331

Project No. - KNMD069212

JANUARY 2012

W90FYQ-09-D-0002

REPAIR JET ENGINE SHOP

68331 EXHIBIT 1B.DWG

[1

'-0

[1

8' -4

[2

3' -4

[1

8' -4

[2

7' -0

[3 8'

-0

PROPOSED 10'X10'

ELEVATOR

PROPOSED

1,400 SF AREA

(SCHEME 1)

60960 [200'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

EXISTING SECOND FLOOR PLAN

FLOOR 2 SAMPLE

LOCATION

DIAGRAM

19-C

19-A - 19-B 20-A - 20-C

21-A - 21-B

21-C

22-A

22-B - 22-C

23-A - 23-B

23-C 24-A - 24-C

29-A - 29-B

29-C

30-A - 30-C

18-A

18-B

18-C

31-A 31-B - 31-C

34-A 34-B - 34-C

35-A - 35-B35-C

36-A - 36-C

Pb-6

Pb-7

Pb-8

Pb-9

Appendix B – Asbestos Containing Material Diagrams

WOMENS

LATRINE

CONTRACTOR

MENS

LATRINE

BREAKROOMNOZZLE

REPAIR

FAN REPAIR

PARTS

STORAGE

PACKING &

CRATING

PACKING &

CRATING

WELDING

SHOP

SUPER

MEN'S

LOCKER

MEN'S

LATRINE

MACHINE SHOP

WELDING

SUPER

OFFICE

MECH

ROOM

CONTRACTOR'S

OFFICE

BEARING

ROOM

PARTS

CLEANING

HALLWAY

AIRCRAFT ENGINE

INSPECTION &

REPAIR SHOP

COURT - YARD

ELEV

TOOL CRIB

S c a le

F o r M ic ro fi lm in g

In c h e s

M ill im e te rs

191 1615141312111098765432 17 18

N

M

L

K

J

I

H

G

F

E

D

C

B

A date detailed checkeddesigned ofsheet sheets project contract rev.drawing fileC O

P Y

R

IG

B U

R N

S A

N D

M cD

O N

N E

LL

E

N G

IN

E

E R

IN

G

C O

M P

A N

Y , I

N C

C

HAWAII AIR NATIONAL GUARD

JOINT BASE PEARL HARBOR - HICKAM

OAHU, HAWAII

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

68331

Project No. - KNMD069212

JANUARY 2012

W90FYQ-09-D-0002

REPAIR JET ENGINE SHOP

68331 EXISTING 1ST FLR.DWG

60960 [200'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[1

'-0

[1

8' -4

[2

3' -4

[1

8' -4

[2

7' -0

[3 8'

-0

EXISTING FIRST FLOOR PLAN

FLOOR 1 ACM

LOCATIONS

BEARING

ROOM

BLACK MASTIC

CONTRACTOR

RESIDUAL BLACK MASTIC

MIRROR MASTIC

VICE

MXG

AMXS

COMMANDER

MXG

XO

MXG

COMMANDER

CONFERENCE

ROOM

CONTRACTOR

OFFICE MOF

CHIEF

CSS

WOMEN'S

LATRINE

MEN'S

LATRINE

WATER

HEATER

JAN

LOCKER

ROOM

M A

IN

TE

N A

N C

E O

FF

IC

E R

MAINTENANCE

CONTROL

COMPUTER

ROOM

STORAGE

CLOSET

UPPER PORTION OF

AIRCRAFT ENGINE

INSPECTION &

REPAIR SHOP

TRAINING

COURT - YARD

BELOW

UPPER PORTION OF

PYLON M.E.R. & T.E.R.

STORAGE

CSS

NCOIC

OFFICE

TRAINING

CLASSROOM

A/V-STORAGE

ROOM

PLANS &

SCHEDULING

MXOP

TESTING

STORAGE

TESTING

UNISEX

LATRINE

LOCKER

ROOM

CSS

NCOIC

OFFICE

ELEV

S c a le

F o r M ic ro fi lm in g

In c h e s

M ill im e te rs

191 1615141312111098765432 17 18

N

M

L

K

J

I

H

G

F

E

D

C

B

A date detailed checkeddesigned ofsheet sheets project contract rev.drawing fileC O

P Y

R

IG

B U

R N

S A

N D

M cD

O N

N E

LL

E

N G

IN

E

E R

IN

G

C O

M P

A N

Y , I

N C

C

HAWAII AIR NATIONAL GUARD

JOINT BASE PEARL HARBOR - HICKAM

OAHU, HAWAII

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

68331

Project No. - KNMD069212

JANUARY 2012

W90FYQ-09-D-0002

REPAIR JET ENGINE SHOP

68331 EXHIBIT 1B.DWG

[1

'-0

[1

8' -4

[2

3' -4

[1

8' -4

[2

7' -0

[3 8'

-0

PROPOSED 10'X10'

ELEVATOR

PROPOSED

1,400 SF AREA

(SCHEME 1)

60960 [200'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

[20'-0"]

EXISTING SECOND FLOOR PLAN

FLOOR 2 ACM

LOCATIONS

VICE

MXG

AMXS

COMMANDER

MXG

XO

MXG

COMMANDER

CONFERENCE

ROOM

CONTRACTOR

OFFICE MOF

CHIEF

CSS

WOMEN'S

LATRINE

MEN'S

LATRINEEENNNNNNNNEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEENNNNNNNNNNNNEEEEEEE

WATERT R

HEATERA RRETE

JANNN

LOCKER

ROOM

M A

IN

TE

N A

N C

E O

FF

IC

E R

MAINTENANCE

CONTROL

COMPUTER

ROOM

CSS

NCOIC

OFFICE

CSS

NCOIC

OFFICE

BLACK MASTIC UNDER

2ND LAYER FLOOR TILE

TRAINING

CLASSROOM

PLANS &

SCHEDULINGN

12" WHITE VINYL FLOOR

TILE

Appendix C – Laboratory Results and Chain of Custody

EMSL Analytical, Inc.

7916 Convoy Court,Building 4, Suite A, San Diego, CA 92111 Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

1A

431202156-0001

DWJC White None Detected Fibrous Homogeneous

Cellulose4% Non-fibrous (other)96%

1B-Drywall

431202156-0002

DWJC White None Detected Fibrous Homogeneous

Cellulose4% Non-fibrous (other)96%

1B-Joint Compound

431202156-0002A

DWJC White None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

1C-Drywall

431202156-0003

DWJC White None Detected Fibrous Homogeneous

Cellulose3% Non-fibrous (other)97%

1C-Joint Compound

431202156-0003A

DWJC White None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

2A

431202156-0004

2'X4' DROP

CEILING

Beige None Detected Fibrous Homogeneous

Cellulose40% Min. Wool25%

Non-fibrous (other)25% Perlite10%

2B

431202156-0005

2'X4' DROP

CEILING

Tan None Detected Fibrous Homogeneous

Cellulose40% Min. Wool30%

Non-fibrous (other)20% Perlite10%

2C

431202156-0006

2'X4' DROP

CEILING

Tan None Detected Fibrous Homogeneous

Cellulose40% Min. Wool30%

Non-fibrous (other)20% Perlite10%

1Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128) http://www.emsl.com mailto:sandiegolab@emsl.com

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

3A-Cove Base

431202156-0007

VINYL COVE

BASE

Blue None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

3A-Mastic

431202156-0007A

VINYL COVE

BASE

Beige None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

3B-Cove Base

431202156-0008

VINYL COVE

BASE

Blue None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

3B-Mastic

431202156-0008A

VINYL COVE

BASE

Beige None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

3C-Cove Base

431202156-0009

VINYL COVE

BASE

Blue None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

3C-Mastic

431202156-0009A

VINYL COVE

BASE

Beige None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

4A

431202156-0010

WATERPROOF

PAPER

Brown/Black None Detected Fibrous Homogeneous

Cellulose60% Non-fibrous (other)40%

4B

431202156-0011

WATERPROOF

PAPER

Brown/Black None Detected Fibrous Homogeneous

Cellulose55% Non-fibrous (other)45%

2Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

4C

431202156-0012

WATERPROOF

PAPER

Brown/Black None Detected Fibrous Homogeneous

Cellulose55% Non-fibrous (other)45%

5A

431202156-0013

CMU BLOCK +

MORTER

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

5B

431202156-0014

CMU BLOCK +

MORTER

Cream None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

5C

431202156-0015

CMU BLOCK +

MORTER

Cream None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

6A

431202156-0016

PLASTER ON

LATHE

Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

6B

431202156-0017

PLASTER ON

LATHE

Brown/Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

6C

431202156-0018

PLASTER ON

LATHE

Brown/Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

7A

431202156-0019

CONCRETE SLAB Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

3Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

7B

431202156-0020

CONCRETE SLAB Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

8A-Drywall

431202156-0021

DWJC White None Detected Fibrous Homogeneous

Cellulose3% Non-fibrous (other)97%

8A-Joint Compound

431202156-0021A

DWJC White None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

8B-Drywall

431202156-0022

DWJC White None Detected Fibrous Homogeneous

Cellulose4% Non-fibrous (other)96%

8B-Joint Compound

431202156-0022A

DWJC White None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

8C-Drywall

431202156-0023

DWJC White None Detected Fibrous Homogeneous

Cellulose3% Non-fibrous (other)97%

8C-Joint Compound

431202156-0023A

DWJC White None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

9A

431202156-0024

2'X4' DROP

CEILING

Tan/White None Detected Fibrous Heterogeneous

Cellulose40% Min. Wool20%

Non-fibrous (other)30% Perlite10%

4Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

9B

431202156-0025

2'X4' DROP

CEILING

Tan None Detected Fibrous Homogeneous

Cellulose40% Min. Wool20%

Non-fibrous (other)30% Perlite10%

9C

431202156-0026

2'X4' DROP

CEILING

Tan None Detected Fibrous Homogeneous

Cellulose40% Min. Wool20%

Non-fibrous (other)30% Perlite10%

10A-Cove Base

431202156-0027

VINYL COVE

BASE

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

10A-Mastic

431202156-0027A

VINYL COVE

BASE

Beige None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

10B-Cove Base

431202156-0028

VINYL COVE

BASE

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

10B-Mastic

431202156-0028A

VINYL COVE

BASE

Beige None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

10C-Cove Base

431202156-0029

VINYL COVE

BASE

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

10C-Mastic

431202156-0029A

VINYL COVE

BASE

Beige None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

5Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

11A-Floor Tile

431202156-0030

12" SPECK VINYL

FLOOR TILE

Tan None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

11A-Mastic

431202156-0030A

12" SPECK VINYL

FLOOR TILE

Yellow None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

11B-Floor Tile

431202156-0031

12" SPECK VINYL

FLOOR TILE

Tan None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

11B-Mastic

431202156-0031A

12" SPECK VINYL

FLOOR TILE

Yellow None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

11C-Floor Tile

431202156-0032

12" SPECK VINYL

FLOOR TILE

Tan None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

11C-Mastic

431202156-0032A

12" SPECK VINYL

FLOOR TILE

Yellow None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

12A

431202156-0033

12" BLUE SPECK

TILE

Blue None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

12B

431202156-0034

12" BLUE SPECK

TILE

Blue None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

6Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

12C

431202156-0035

12" BLUE SPECK

TILE

Blue None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

13A-Floor Tile

431202156-0036

12" WHITE

W/BROWN

SPECK VFT

Tan None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

13A-Mastic

431202156-0036A

12" WHITE

W/BROWN

SPECK VFT

Black Non-Fibrous Homogeneous

Chrysotile3%Non-fibrous (other)97%

13B-Floor Tile

431202156-0037

12" WHITE

W/BROWN

SPECK VFT

Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

13B-Mastic

431202156-0037A

12" WHITE

W/BROWN

SPECK VFT

Black Non-Fibrous Homogeneous

Chrysotile4%Non-fibrous (other)96%

13C-Floor Tile

431202156-0038

12" WHITE

W/BROWN

SPECK VFT

Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

13C-Mastic

431202156-0038A

12" WHITE

W/BROWN

SPECK VFT

Black Non-Fibrous Homogeneous

Chrysotile3%Non-fibrous (other)97%

14A-Floor Tile

431202156-0039

12" BROWN

FAUX WOOD VFT

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

7Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

14A-Mastic

431202156-0039A

12" BROWN

FAUX WOOD VFT

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

14B-Floor Tile

431202156-0040

12" BROWN

FAUX WOOD VFT

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

14B-Mastic

431202156-0040A

12" BROWN

FAUX WOOD VFT

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

14C-Floor Tile

431202156-0041

12" BROWN

FAUX WOOD VFT

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

14C-Mastic

431202156-0041A

12" BROWN

FAUX WOOD VFT

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

15A

431202156-0042

WINDOW

CAULKING

Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

15B

431202156-0043

WINDOW

CAULKING

Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

15C

431202156-0044

WINDOW

CAULKING

Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

8Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

16A

431202156-0045

WINDOW

CAULKING

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

16B

431202156-0046

WINDOW

CAULKING

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

16C

431202156-0047

WINDOW

CAULKING

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

17A

431202156-0048

HVAC MASTIC Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

17B

431202156-0049

HVAC MASTIC Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

17C

431202156-0050

HVAC MASTIC Gray None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

19A-Floor Tile

431202156-0051

12" FAUX

MARBLE VFT

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

19A-Mastic

431202156-0051A

12" FAUX

MARBLE VFT

Brown/Clear None Detected Non-Fibrous Heterogeneous

Non-fibrous (other)100%

9Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 10/24/2012 13:29:56

Rebecca Luu (128)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.emsl.com sandiegolab@emsl.com

431202156 CustomerID: 32EVSW63 CustomerPO:

ProjectID:

EMSL Order:

Attn: Heath Howard TRC Environmental Corp.

677 Ala Moana Blvd.

Suite 920 Honolulu, HI 96813

Received: 10/19/12 12:00 PM

198110 HICKAM BLD 3416

Fax:

Phone: (808) 728-4111

Project:

10/24/2012Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

19B-Floor Tile

431202156-0052

12" FAUX

MARBLE VFT

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

19B-Mastic

431202156-0052A

12" FAUX

MARBLE VFT

Brown/Clear None Detected Non-Fibrous Heterogeneous

Non-fibrous (other)100%

19C-Floor Tile

431202156-0053

12" FAUX

MARBLE VFT

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

19C-Mastic

431202156-0053A

12" FAUX

MARBLE VFT

Brown/Clear None Detected Non-Fibrous Heterogeneous

Non-fibrous (other)100%

20A-Cove Base

431202156-0054

VINYL COVE

BASE

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

20A-Mastic 1

431202156-0054A

VINYL COVE

BASE

Beige None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

20A-Mastic 2

431202156-0054B

VINYL COVE

BASE

Brown None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

20B-Cove Base

431202156-0055

VINYL COVE

BASE

Black None Detected Non-Fibrous Homogeneous

Non-fibrous (other)100%

10Test Report PLM-7.16.0 Printed: 10/24/2012 1:29:56 PM

Michelle LaVallee, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis.