This document is a Water Well Record form completed by the South Carolina Department of Health and Environmental Control (DHEC) for a water well drilled in Richland County. The well was drilled on 12-22-2022 to a total depth of 52.1 feet using a hollow-stem auger drilling method with a 2-inch PVC casing and screen. The well stratigraphy includes layers of silty sand, poorly graded sand, poorly graded gravel, lean clay, and additional silty sand, with a bentonite pellet layer installed from 37.4 to 39.6 feet. The well is classified as a monitor well for Akshai M. Gandhi, located at 1325 S. Carolina Rd., Ste 20 in Eastover, SC, with the nearest potential contamination source (jet fuel) located 220 feet to the northwest.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers 1.pdf | ||
| MW-07 Well Record.pdf | ||
| Solicitation W912HN25Q5006.docx.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DHEC 1903 (08/2017) COPY 1 MAIL TO SCDHEC, COPY 2 TO WELL OWNER, COPY 3 TO WELL DRILLER
Water Well Record Bureau of Water
2600 Bull Street, Columbia, SC 29201-1708; (803) 898-4300
1. WELL OWNER INFORMATION:
Name:
(last) (first)
Address:
City: State: Zip:
Telephone: Work: Home:
2. LOCATION OF WELL: COUNTY:
Name:
Street Address:
City: Zip:
Latitude: Longitude:
3. PUBLIC SYSTEM NAME: PUBLIC SYSTEM NUMBER:
4. ABANDONMENT: Yes No Give Details Below
Grouted Depth: from ft. to ft.
*Thickness Depth to
Formation Description of Bottom of Stratum Stratum
*Indicate Water Bearing Zones
(Use a 2nd sheet if needed)
5. REMARKS:
6. TYPE: Mud Rotary Jetted Bored Dug Air Rotary Driven Cable tool Other
7. PERMIT NUMBER:
8. USE:
Residential Public Supply Process Irrigation Air Conditioning Emergency Test Well Monitor Well Replacement
9. WELL DEPTH (completed) Date Started:
ft. Date Completed:
10. CASING: Threaded Welded
Diam.: Height: Above/Below Type: PVC Galvanized Surface ft.
Steel Other Weight lb./ft.
in. to ft. depth Drive Shoe? Yes No
in. to ft. depth
11. SCREEN:
Type: Diam.:
Slot/Gauge: Length:
Set Between: ft. and ft. NOTE: MULTIPLE SCREENS
ft. and ft. USE SECOND SHEET Sieve Analysis Yes (please enclose) No
12. STATIC WATER LEVEL ft. below land surface after 24 hours
13. PUMPING LEVEL Below Land Surface.
ft. after hrs. Pumping G.P.M.
Pumping Test: Yes (please enclose) No Yield:
14. WATER QUALITY
Chemical Analysis Yes No Bacterial Analysis Yes No Please enclose lab results.
15. ARTIFICIAL FILTER (filter pack) Yes No Installed from ft. to ft.
Effective size Uniformity Coefficient
16. WELL GROUTED? Yes No Neat Cement Bentonite Bentonite/Cement Other
Depth: From ft. to f t .
17. NEAREST SOURCE OF POSSIBLE CONTAMINATION: ft. direction Type Well Disinfected Yes No Type: Amount:
18. PUMP: Date installed: Not installed Mfr. Name: Model No.:
H.P. Volts Length of drop pipe ft. Capacity gpm TYPE: Submersible Jet (shallow) Turbine
Jet (deep) Reciprocating Centrifugal
19. WELL DRILLER: CERT. NO.:
Address: (Print) Level: A B C D (circle one)
Telephone No.: Fax No.:
20. WATER WELL DRILLER’S CERTIFICATION: This well was drilled under my direction and this report is true to the best of my knowledge and belief.
Signed: Date:
If D Level Driller, provide supervising driller's name:
Well Driller
Note: Personal information provided on this document is subject to public scrutiny or release.
(MACROCORE LOGGING)
HOLLOW-STEM AUGER
DRILLING METHOD
| name: GANDHI, AKSHAI M. |
| street: 1325 S. CAROLINA RD, STE 20 |
| city: EASTOVER |
| state: SC |
| zip: 29044-0000 |
| work#: 803-647-8535 |
| home#: |
| welllocation: McEntire |
| county: RICHLAND |
| locname: MW-08 |
| locst: 1325 S. CAROLINA RD, STE 20 |
| loccity: EASTOVER |
| loczip: 29044-0000 |
| welllat: |
| welllong: |
| sysname: |
| sysnumber: Not Applicable |
| abandno: Yes |
| abandyes: Off |
| gdepthfrom: |
| gdepthto: |
| desc1: SILTY SAND |
| desc2: POORLY GRADED SAND |
| desc3: POORLY GRADED GRAVEL |
| desc4: LEAN CLAY |
| desc5: SILTY SAND |
| desc6: |
| desc7: |
| desc8: |
| desc9: |
| desc10: |
| desc11: |
| desc12: |
| stratumthick1: 15' |
| stratumthick2: 15' |
| stratumthick3: 9' |
| stratumthick4: 3' |
| stratumthick5: 13' |
| stratumthick6: |
| stratumthick7: |
| stratumthick8: |
| stratumthick9: |
| stratumthick10: |
| stratumthick11: |
| stratumthick12: |
| stratdepth1: 15' |
| stratdepth2: 30' |
| stratdepth3: 39' |
| stratdepth4: 42' |
| stratdepth5: 55' |
| stratdepth6: |
| stratdepth7: |
| stratdepth8: |
| stratdepth9: |
| stratdepth10: |
| stratdepth11: |
| stratdepth12: |
| wbz1: |
| wbz2: |
| remarks1: Bentonite pellet layer installed from 37.4 ft to 39.6 ft. |
| remarks2: |
| remarks3: |
| mud: Off |
| dug: Off |
| cable: Off |
| jetted: Off |
| air: Off |
| otherdrill: Off |
| bored: Yes |
| driven: Off |
| use1: Off |
| use2: Off |
| use3: Off |
| use4: Off |
| use5: Off |
| use6: Yes |
| use7: Off |
| use8: Off |
| use9: Off |
| depthcomplete: 52.1 |
| datestart: 12-22-2022 |
| datecomplete: 12-22-2022 |
| threaded: Yes |
| welded: Off |
| casing diameter: 2 inch |
| pvc: Yes |
| steel: Off |
| galv: Off |
| othercasing: Off |
| casing1: |
| casing2: |
| casing3: |
| casing4: |
| height2: Yes |
| surface: |
| weight: |
| drive: Off |
| drive1: Off |
| screen type: PVC |
| screen diameter: 2 inch |
| gauge: 0.010 inch |
| screen length: 10 feet |
| set1: 42 |
| set2: 52 |
| set3: |
| set4: |
| sieve: Off |
| sieve2: Yes |
| water level: 47.40 |
| pumping level: |
| hours: |
| gpm: |
| pumptest1: Off |
| pumptest2: Yes |
| yield: |
| chem: Off |
| chemno: Yes |
| bactyes: Off |
| bactno: Yes |
| filteryes: Yes |
| filterno: Off |
| filterfrom: 39.6 |
| filterto: 52 |
| effsize: |
| uc: |
| groutyes: Yes |
| groutno: Off |
| neat: Off |
| bentonite: Off |
| bc: Yes |
| othergrout: Off |
| othergrout1: |
| groutfrom: 0 |
| groutto: 37.4 |
| contamft: 220 |
| contamdirction: NW |
| contamtype: Jet Fuel |
| disinfect: Off |
| disno: Yes |
| distype: |
| disamount: |
| datepump: |
| nopump: Yes |
| manuf: |
| model: |
| hp: |
| volts: |
| drop: |
| capacity: |
| sub: Off |
| jetpump: Off |
| jetshallo: Off |
| recip: Off |
| turbine: Off |
| centrif: Off |
| driller: USACE |
| certification: |
| a: Off |
| drilleraddress: 100 W. Oglethorpe Ave., |
Savannah GA 31401
| drillerphone: 912-652-5670 |
| drillerfax: 912-652-5311 |
| formdate: |
| permit: DHEC Letter of December 9, 2023. |
| drillers name: USACE On Site Driller: Ed Ratliff |
File details come from the government source that posted it. Updated .