This document provides details on a federal contract solicitation for construction services. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Savannah on July 16, 2020 under number W912HN20B3012 for construction of a Company Operations Facility at Fort Benning, Georgia. One drawing file and three specifications files are included. Bids for the project are due by August 19, 2020 at 2:00pm Eastern Time. The solicitation seeks construction services for a new Company Operations Facility and includes bidding documents such as drawings and specifications to guide contractor responses. The response due date is August 19th at 2pm ET.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8/4/20208/04/2020
08/04/20
VICINITY MAP
NO SCALE
ATLANTA
FORT BENNING
COLUMBUS
MACON
AUGUSTA
SAVANNAH
ALBANY
STATE OF GEORGIA
NO SCALE
CONTRACTOR ENTRANCE
U.S. HIGHWAY 27/280
HAUL ROUTE
CUSSETA
CHATTAHOOCHEE
RIVER
G E O R G I A
MITCHELL
FORT
MILITARY
RESERVATION
FORT BENNING
COLUMBUS
PHENIX CITY
FLOURNOYS
FORT
MITCHELL
LAWSON
AAF
85 80
VESPER
IDA
CHATTAHOOCHEE
COUNTY
COMPANY OPERATIONS
BUILDING
PROJECT LOCATION
LO
C
AT
IO
N P
LA
N
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1G -0
.d w g
G-003
W
2H N
-2 0-
B-
G . L
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
O
VE
R
AL
L
SU
R
VE
Y
PL
AN
N
40' 20' 0 40' 80' 120'
GRAPHIC SCALE: 1" = 40'
V-111
V-112
GENERAL SURVEY NOTES
1. NO UNDERGROUND INSTALLATION OR IMPROVEMENTS
HAVE BEEN LOCATED EXCEPT THOSE SHOWN HEREON.
2. LOWE ENGINEERS' CERTIFICATE OF AUTHORIZATION
NUMBER TO PROVIDE SURVEYING SERVICES IN GEORGIA
IS COA 648.
3. AS USED ON THIS DRAWING, CERTIFY MEANS TO STATE
OR DECLARE A PROFESSIONAL OPINION OF CONDITIONS
REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE
SUBJECT OF THE CERTIFICATION AND DOES NOT
CONSTITUTE A WARRANTY OF GUARANTEE, EITHER
EXPRESSED OR IMPLIED. THIS CERTIFICATION IS ONLY
FOR THE LANDS AS DESCRIBED. IT IS NOT A CERTIFICATE
OF TITLE, ZONING, EASEMENTS OR FREEDOM OF
ENCUMBRANCES.
4. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS,
RIGHTS-OF-WAY AND/OR OWNERSHIP WERE FURNISHED
THIS SURVEYOR EXCEPT AS SHOWN HEREON.
5. VERTICAL DATUM NOTE. THE ELEVATIONS SHOWN HERON
ARE REFERENCED TO NAVD 1988.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1V -1
.d w g
V-101
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
SU
R
VE
Y
PL
AN
N
10' 5' 0 10' 20' 30'
GRAPHIC SCALE: 1" = 10'
KEYMAP
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1V -1
.d w g
V-111
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
SU
R
VE
Y
PL
AN
N
10' 5' 0 10' 20' 30'
GRAPHIC SCALE: 1" = 10'
KEYMAP
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1V -1
.d w g
V-112
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
O
VE
R
AL
L
BO
R
IN
G L
AY
O
U T
PL
AN
N
40' 20' 0 40' 80' 120'
GRAPHIC SCALE: 1" = 40'
LEGEND
BORING LOCATION.
B-01
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1B -1
.d w g
B-101
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
BO
R
IN
G
L O
G S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1B -3
.d w g
B-301
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
BO
R
IN
G
L O
G S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1B -3
.d w g
B-302
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
W W W
LPG
E E E
E E E
NPW
A CLR CLEAR, ELECT ELECTRIC G J O Q ST STREET V
ABN ABANDON CLEARANCE ELEV ELEVATION GA GAGE J OC OVERCROSSING QTY QUANTITY STA STATION V VALVE, ABUT ABUTMENT CM CORRUGATED METAL EMB EMBANKMENT GALV GALVANIZED JCT JUNCTION OD OUTSIDE DIAMETER STD STANDARD VAR VARIABLE
AC ASPHALT CONCRETE CMP CORRUGATED METAL PIPE ENGR ENGINEER GP GRADING PLAN JB JUNCTION BOX OF OUTSIDE FACE R STR STRUCTURE VC VERTICAL CURVE
ADJ ADJUST CO CLEANOUT EP EDGE OF PAVEMENT GR GUARD RAILING JT JOINT OG ORIGINAL GROUND R RADIUS SURF SURFACING VCP VITRIFIED CLAY PIPE
AHD AHEAD COL COLUMN EQ EQUATION GSP GALVANIZED STEEL PIPE OH OVERHEAD RCP REINFORCED CONCRETE PIPE SW SIDEWALK, VERT VERTICAL
ALT ALTERNATE CONC CONCRETE ES EDGE OF SHOULDER GTR GUTTER L OPP OPPOSITE RD ROAD SWR SEWER VOL VOLUME
APPROX APPROXIMATE CONST CONSTRUCT, ETW EDGE OF TRAVELED WAY L LENGTH REINF REINFORCED, SYM SYMMETRICAL
ASSY ASSEMBLY CONSTRUCTION EVC END VERTICAL CURVE H LAT LATITUDE P REL RELOCATE W
ATFP ANTI TERRORISM FORCE CONT CONTINUOUS EW ENDWALL H HEIGHT LOC LOCATION P PAGE REPL REPLACEMENT T W WEST, PROTECTION COORD COORDINATE EXC EXCAVATION H, HR HOUR LONG LONGITUDE PB PULL BOX RET RETAINING TAN TANGENT WIDTH
AVE AVENUE CTRS CENTERS EXIST EXISTING HD HORIZONTAL DRAIN LONGIT LONGITUDINAL PC POINT OF CURVATURE, REV REVISED TBR TIMBER WT WEIGHT
AVG AVERAGE CULV CULVERT EXP EXPANSION, HDWL HEADWALL LT LEFT PRECAST RDWY ROADWAY TC TOP OF CURB WV WATER VALVE @ AT CL CENTERLINE EXPRESSWAY HORIZ HORIZONTAL PCC POINT OF COMPOUND CURVE, RR RAILROAD TEL TELEPHONE WW WINGWALL
EXP JT EXPANSION JOINT HP HINGE POINT, M PCVC POINT OF COMPOUND VERTICAL CURVE RSP ROCK SLOPE PROTECTION TEMP TEMPORARY
B D EXT EXTERIOR HORSEPOWER MAINT MAINTENANCE PED PEDESTRIAN RT RIGHT TG TOP OF GRATE X
BC BEGIN HORIZONTAL CURVE D DEPTH HS HIGH STRENGTH MAX MAXIMUM PG PROFILE GRADE RTE ROUTE TOT TOTAL X SEC CROSS SECTION
BCR BEGIN CURB RETURN DD DOWNDRAIN F HW HEADWALL, MEP MILITARY EQUIPMENT PI POINT OF INTERSECTION R/W RIGHT OF WAY TP TELEPHONE POLE XING CROSSING
BEG BEGIN DBL DOUBLE FB FLOOR BEAM HIGH WATER PARKING P/L PROPERTY LINE RWY RAILWAY TRANS TRANSITION
BK BACK DEG DEGREE FDN FOUNDATION HWM HIGH WATER MARK MH MANHOLE POC POINT OF HORIZONTAL CURVE TS TRANSVERSE Y
BKF BACKFILL DIA DIAMETER FF FILTER FABRIC HWY HIGHWAY MIN MINIMUM POT POINT OF TANGENT S TRAFFIC SIGNAL, YR YEAR
BLDG BUILDING DIAPH DIAPHRAGM FG FINISHED GRADE MISC MISCELLANEOUS POVC POINT OF VERTICAL CURVE S SOUTH, TUBULAR STEEL YRS YEARS
BLVD BOULEVARD DIST DISTANCE, FH FIRE HYDRANT I MKR MARKER PP POWER POLE SALV SALVAGE TYP TYPICAL
BM BENCH MARK DISTRICT FIG FIGURE ID INSIDE DIAMETER MOD MODIFIED, PPL PREFORMED PERMEABLE LINER SD STORM DRAIN
BOT BOTTOM DR DRIVE FL FLOW LINE IF INSIDE FACE MODIFY PRC POINT OF REVERSE CURVE SEC SECOND, U
BVC BEGIN VERTICAL CURVE FOB FREE ON BOARD INT INTERIOR MON MONUMENT PRF PAVEMENT REINFORCING FABRIC SECTION USAR UNITED STATES ARMY
BW BARBED WIRE E FOC FACE OF CONCRETE INV INVERT MTL MATERIAL PRVC POINT OF REVERSE VERTICAL CURVE SEP SEPARATION RESERVE
E EAST FR RD FRONTAGE ROAD IRR IRRIGATION PERF PERFORATED SHLD SHOULDER
C EASE EASEMENT FTG FOOTING N PT POINT OF TANGENCY SHT SHEET
CB CATCH BASIN EC END HORIZONTAL CURVE N NORTH PVC POLYVINYL CHLORIDE SIM SIMILAR
CHNL CHANNEL ECR END CURB RETURN NB NORTHBOUND PVMT PAVEMENT SPEC SPECIAL,
CI CURB INLET ED EDGE DRAIN NO. NUMBER SPECIFICATIONS
CIP CAST-IN-PLACE, NTS NOT TO SCALE
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
C
IV
IL
L
EG
EN
D A
N D
AB
BR
EV
AT
IO
N
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C -0
.d w g
C-001
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
GENERAL SURVEY NOTES
1. NO UNDERGROUND INSTALLATION OR IMPROVEMENTS
HAVE BEEN LOCATED EXCEPT THOSE SHOWN HEREON.
2. LOWE ENGINEERS' CERTIFICATE OF AUTHORIZATION
NUMBER TO PROVIDE SURVEYING SERVICES IN GEORGIA
IS COA 648.
3. AS USED ON THIS DRAWING, CERTIFY MEANS TO STATE
OR DECLARE A PROFESSIONAL OPINION OF CONDITIONS
REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE
SUBJECT OF THE CERTIFICATION AND DOES NOT
CONSTITUTE A WARRANTY OF GUARANTEE, EITHER
EXPRESSED OR IMPLIED. THIS CERTIFICATION IS ONLY
FOR THE LANDS AS DESCRIBED. IT IS NOT A CERTIFICATE
OF TITLE, ZONING, EASEMENTS OR FREEDOM OF
ENCUMBRANCES.
4. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS,
RIGHTS-OF-WAY AND/OR OWNERSHIP WERE FURNISHED
THIS SURVEYOR EXCEPT AS SHOWN HEREON.
5. VERTICAL DATUM NOTE. THE ELEVATIONS SHOWN HERON
ARE REFERENCED TO NAVD 1988.
GENERAL SURVEY NOTES
1. NO UNDERGROUND INSTALLATION OR IMPROVEMENTS
HAVE BEEN LOCATED EXCEPT THOSE SHOWN HEREON.
2. LOWE ENGINEERS' CERTIFICATE OF AUTHORIZATION
NUMBER TO PROVIDE SURVEYING SERVICES IN GEORGIA
IS COA 648.
3. AS USED ON THIS DRAWING, CERTIFY MEANS TO STATE
OR DECLARE A PROFESSIONAL OPINION OF CONDITIONS
REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE
SUBJECT OF THE CERTIFICATION AND DOES NOT
CONSTITUTE A WARRANTY OF GUARANTEE, EITHER
EXPRESSED OR IMPLIED. THIS CERTIFICATION IS ONLY
FOR THE LANDS AS DESCRIBED. IT IS NOT A CERTIFICATE
OF TITLE, ZONING, EASEMENTS OR FREEDOM OF
ENCUMBRANCES.
4. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS,
RIGHTS-OF-WAY AND/OR OWNERSHIP WERE FURNISHED
THIS SURVEYOR EXCEPT AS SHOWN HEREON.
5. VERTICAL DATUM NOTE. THE ELEVATIONS SHOWN HERON
ARE REFERENCED TO NAVD 1988.
1. CONTRACTOR SHALL CONTACT GEORGIA 811 BEFORE
COMMENCING ANY LAND DISTURBANCE ACTIVITIES.
2. BACK FILL VOIDS LEFT BY DEMOLITION TO ADJACENT
GRADE. REFER TO SPECIFICATION 31 00 00 EARTHWORK.
3. ALL DEMOLITION DEBRIS SHALL BE REMOVED FROM FORT
BENNING AND DISPOSED OF IN A LEGAL AND REGULATED
MANNER AT NO ADDITIONAL EXPENSE TO THE
GOVERNMENT.
4. CONTRACTOR SHALL COORDINATE UTILITY DEMOLITION
WITH THE UTILITY OWNER.
GENERAL DEMOLITION NOTES
1. CONTRACTOR SHALL CONTACT GEORGIA 811 BEFORE
COMMENCING ANY LAND DISTURBANCE ACTIVITIES.
2. BACK FILL VOIDS LEFT BY DEMOLITION TO ADJACENT
GRADE. REFER TO SPECIFICATION 31 00 00 EARTHWORK.
3. ALL DEMOLITION DEBRIS SHALL BE REMOVED FROM FORT
BENNING AND DISPOSED OF IN A LEGAL AND REGULATED
MANNER AT NO ADDITIONAL EXPENSE TO THE
GOVERNMENT.
4. CONTRACTOR SHALL COORDINATE UTILITY DEMOLITION
WITH THE UTILITY OWNER.
GENERAL DEMOLITION NOTES
1. REFER TO SHEET CD101 FOR LIMITS OF CONSTRUCTION
NORTHING/EASTINGS.
GENERAL SITE LAYOUT NOTES
1. REFER TO SHEET CD101 FOR LIMITS OF CONSTRUCTION
NORTHING/EASTINGS.
GENERAL SITE LAYOUT NOTES
1. REFER TO SHEETCG701 THRU CG819 FOR EROSION AND
SEDIMENT CONTROL PLAN.
2. REFER TO SHEET C-001 FOR CIVIL LEGEND.
GENERAL GRADING NOTES
1. REFER TO SHEETCG701 THRU CG819 FOR EROSION AND
SEDIMENT CONTROL PLAN.
2. REFER TO SHEET C-001 FOR CIVIL LEGEND.
GENERAL GRADING NOTES
GENERAL EROSION NOTES
1. ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD
GREATER THAN 14 DAYS SHALL BE STABILIZED WITH
MULCH (Ds1) OR TEMPORARY SEEDING (Ds2) IF THE AREA
IS EXPECTED TO BE UNDISTURBED FOR LESS THAN 6
MONTHS. IF THE AREA WILL NOT BE DISTURBED FOR 6
MONTHS OR MORE, THEN THE AREA MUST BE STABILIZED
USING PERMANENT STABILIZATION (Ds3).
2. DUST CONTROL (Du) SHALL BE UTILIZED AS NEEDED ON
THE PROJECT SITE FOR THE ENTIRE CONSTRUCTION
PERIOD.
GENERAL EROSION NOTES
1. ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD
GREATER THAN 14 DAYS SHALL BE STABILIZED WITH
MULCH (Ds1) OR TEMPORARY SEEDING (Ds2) IF THE AREA
IS EXPECTED TO BE UNDISTURBED FOR LESS THAN 6
MONTHS. IF THE AREA WILL NOT BE DISTURBED FOR 6
MONTHS OR MORE, THEN THE AREA MUST BE STABILIZED
USING PERMANENT STABILIZATION (Ds3).
2. DUST CONTROL (Du) SHALL BE UTILIZED AS NEEDED ON
THE PROJECT SITE FOR THE ENTIRE CONSTRUCTION
PERIOD.
1. CONTRACTOR SHALL COORDINATE UTILITY WORK WITH
THE SERVICE PROVIDER.
2. NEW SANITARY SEWER LINES SHOWN ARE TO BE
CONSTRUCTED BY COLUMBUS WATER WORKS TO THE
POINT OF DEMARCATION. POINT OF DEMARCATION IS 5
FEET OUTSIDE BUILDING FOUNDATION.
3. NEW DOMESTIC WATER AND FIRE WATER LINES SHOWN
ARE TO BE CONSTRUCTED BY COLUMBUS WATER WORKS
TO THE POINT OF DEMARCATION. POINT OF
DEMARCATION IS 5 FEET OUTSIDE BUILDING FOUNDATION.
4. NEW GAS LINES SHOWN ARE TO BE CONSTRUCTED BY
LIBERTY UTILITIES COLUMBUS TO THE POINT OF
DEMARCATION. POINT OF DEMARCATION IS THE GAS
METER DISCHARGE.
GENERAL UTILITY NOTES
1. CONTRACTOR SHALL COORDINATE UTILITY WORK WITH
THE SERVICE PROVIDER.
2. NEW SANITARY SEWER LINES SHOWN ARE TO BE
CONSTRUCTED BY COLUMBUS WATER WORKS TO THE
POINT OF DEMARCATION. POINT OF DEMARCATION IS 5
FEET OUTSIDE BUILDING FOUNDATION.
3. NEW DOMESTIC WATER AND FIRE WATER LINES SHOWN
ARE TO BE CONSTRUCTED BY COLUMBUS WATER WORKS
TO THE POINT OF DEMARCATION. POINT OF
DEMARCATION IS 5 FEET OUTSIDE BUILDING FOUNDATION.
4. NEW GAS LINES SHOWN ARE TO BE CONSTRUCTED BY
LIBERTY UTILITIES COLUMBUS TO THE POINT OF
DEMARCATION. POINT OF DEMARCATION IS THE GAS
METER DISCHARGE.
GENERAL UTILITY NOTES
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
C
IV
IL
G
EN
ER
AL
N
O
TE
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C -0
.d w g
C-002
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
O
VE
R
AL
L D
EM
O
LI
TI
O N
P
LA
N
N
40' 20' 0 40' 80' 120'
GRAPHIC SCALE: 1" = 40'
CD111
CD112
LEGEND
LIMITS OF DISTURBANCE
LIMITS OF CONSTRUCTION
CONTRACTOR LAY DOWN AREA
TEMPORARY CONSTRUCTION FENCE
SHEET KEYNOTES
1. CONTRACTOR SHALL MAINTAIN AT LEAST ONE LANE OF
TRAFFIC AT ALL TIMES DURING CONSTRUCTION.
1. CONTRACTOR SHALL CONTACT GEORGIA 811 BEFORE
COMMENCING ANY LAND DISTURBANCE ACTIVITIES.
2. BACK FILL VOIDS LEFT BY DEMOLITION TO ADJACENT
GRADE. REFER TO SPECIFICATION 31 00 00 EARTHWORK.
3. ALL DEMOLITION DEBRIS SHALL BE REMOVED FROM FORT
BENNING AND DISPOSED OF IN A LEGAL AND REGULATED
MANNER AT NO ADDITIONAL EXPENSE TO THE
GOVERNMENT.
4. CONTRACTOR SHALL COORDINATE UTILITY DEMOLITION
WITH THE UTILITY OWNER.
GENERAL DEMOLITION NOTES
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C D
1.
dw g
CD101
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
D
EM
O
LI
TI
O
N P
LA
N
N
10' 5' 0 10' 20' 30'
GRAPHIC SCALE: 1" = 10'
SHEET KEYNOTES
1. REMOVE EXISTING SIDEWALK. PROVIDE NEAT SAWCUT.
2. REMOVE EXISTING BUILDING 5015 & FOUNDATION. REFER
TO SPECIFICATION 02 41 00 DEMOLITION.
3. REMOVE EXISTING WOOD CANOPY AND CONCRETE
FOUNDATION.
4. REMOVE EXISTING UNDERGROUND GAS LINE. CAP END TO
REMAIN.
5. REMOVE EXISTING A/C MECHANICAL UNIT.
6. REMOVE EXISTING SHED.
7. REMOVE EXISTING CONCRETE PAD AND WALL.
8. REMOVE EXISTING GRAVEL PAVEMENT.
9. REMOVE EXISTING CURB & GUTTER.
10. REMOVE EXISTING BITUMINOUS PAVEMENT.
11. EXISTING WATER METER SHALL BE REMOVED BY
COLUMBUS WATER WORKS. CONTRACTOR SHALL
COORDINATE ALL WATER LINE REMOVAL WITH COLUMBUS
WATER WORKS. POINT OF DEMARCATION IS 5 FEET
OUTSIDE OF BUILDING.
12. EXISTING SANITARY SEWER CLEANOUT AND LINE SHALL
BE REMOVED BY COLUMBUS WATER WORKS.
CONTRACTOR SHALL COORDINATE ALL SANITARY SEWER
DEMOLITION WITH COLUMBUS WATER WORKS.
DEMARCATION IS 5 FEET OUTSIDE OF BUILDING.
13. REFER TO ELECTRICAL.
14. REFER TO ELECTRICAL.
15. REMOVE EXISTING SIGN.
16. REMOVE EXISTING TREE.
17. PROVIDE NEAT STRAIGHT SAWCUT PRIOR TO PAVEMENT
REMOVAL.
18. REMOVE EXISTING RAILROAD TIE EDGING.
19. REMOVE EXISTING 6" HDPE STORM DRAIN.
20. PROVIDE TEMPORARY CONSTRUCTION FENCE AROUND
SITE. GROUND DISTURBED WITH CONSTRUCTION OR
DEMOLITION OF TEMPORARY FENCE SHALL BE RESTORED
TO PRE-CONSTRUCTION CONDITION.
21. REMOVE EXISTING STORM DRAIN PIPE.2
5 5
END
END
20 20
LEGEND
LIMITS OF DISTURBANCE
LIMITS OF CONSTRUCTION
CONTRACTOR LAY DOWN AREA
TEMPORARY CONSTRUCTION FENCE
ITEMS TO BE REMOVED
KEYMAP
END
END
21 21
END
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C D
1.
dw g
CD111
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
D
EM
O
LI
TI
O
N P
LA
N
N
10' 5' 0 10' 20' 30'
GRAPHIC SCALE: 1" = 10'
SHEET KEYNOTES
1. PROVIDE TEMPORARY CONSTRUCTION FENCE AROUND
SITE. GROUND DISTURBED WITH CONSTRUCTION OR
DEMOLITION OF TEMPORARY FENCE SHALL BE RESTORED
TO PRE-CONSTRUCTION CONDITION.
2. CONTRACTOR LAY DOWN AREA. DISTURBED GROUND
SHALL BE RESTORED TO PRE-CONSTRUCTION CONDITION.
LEGEND
LIMITS OF DISTURBANCE
LIMITS OF CONSTRUCTION
CONTRACTOR LAY DOWN AREA
TEMPORARY CONSTRUCTION FENCE2
KEYMAP
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C D
2.
dw g
CD112
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
O
VE
R
AL
L
LA
YO
U
T
PL
AN
N
40' 20' 0 40' 80' 120'
GRAPHIC SCALE: 1" = 40'
CS111
LEGEND
LIMITS OF DISTURBANCE
LIMITS OF CONSTRUCTION
ASPHALT PAVEMENT
CURB AND GUTTER
1. REFER TO SHEET CD101 FOR LIMITS OF CONSTRUCTION
NORTHING/EASTINGS.
GENERAL SITE LAYOUT NOTES
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C S1
.d w g
CS101
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
LA
YO
U T
PL
AN
N
10' 5' 0 10' 20' 30'
GRAPHIC SCALE: 1" = 10'
3 3
2 2
5 4
8'x4' 8'x4' 8'x4'
6'x5'
10'x5'
6'x5'
2 6'x5'
6'
.0
9'
135.69'
6'
2 10'x5'
1. PROVIDE CONCRETE SIDEWALK. REFER TO DETAIL 3,
SHEET CS501.
2. PROVIDE CONCRETE STOOP. REFER TO DETAIL 2, SHEET
CS501.
3. PROVIDE BITUMINOUS PAVEMENT. REFER TO DETAIL 1,
SHEET CS501.
4. PROVIDE NEW 2' CURB AND GUTTER. REFER TO DETAIL 2,
SHEET CS502.
5. PROVIDE HANDICAP RAMP. REFER TO DETAIL 1, SHEET
CS502.
6. PROVIDE CONCRETE STAIRS. REFER TO DETAIL 1, SHEET
CS503.
7. PROVIDE SIDEWALK DRAIN. REFER TO DETAIL 3, SHEET
CS502.
8. PROVIDE CONCRETE EQUIPMENT PAD. REFER TO DETAIL
2, SHEET CS501.
SHEET KEYNOTES
1 14'
LEGEND
LIMITS OF DISTURBANCE
LIMITS OF CONSTRUCTION
ASPHALT PAVEMENT
CURB AND GUTTER
KEYMAP
11.72' 13.97'
5.4'
18.23°
MATCH EXISTING
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C S1
.d w g
CS111
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
MEDIUM-DUTY
BITUMINOUS PAVEMENT
GEORGIA DEPARTMENT OF
TRANSPORTATION STANDARD
SPECIFICATIONS CONSTRUCTION
OF TRANSPORTATION SYSTEMS
1.5" OF 9.5mm BITUMINOUS SURFACE
COURSE
TACK COAT
2" OF 12.5mm BITUMINOUS BASE
COURSE
9" GDOT GROUP II GRADED
AGGREGATE BASE, SECTION 815*
12" RAW SUBGRADE COMPACTED 90%
OF LABORATORY MAXIMUM DENSITY
(ASTM D 1557)
1 DETAIL
NOT TO SCALE
EXACT UTILITY PAD DIMENSIONS AND
LOCATIONS OF OPENINGS AND SLEEVES
THROUGH PAD TO BE COORDINATED WITH
EQUIPMENT SUPPLIERS. PAD TO BE A MINIMUM
OF 1'-0" LARGER THAN EQUIPMENT ON ALL SIDES.
FLUSH AT
PAVED AREAS
CONCRETE EQUIPMENT PAD & STOOPS
6" 6"
3/4" CHAMFER IN
TURF AREAS
FINISH GRADE6x6W2.9xW2.9
WELDED WIRE FABRIC
6" GDOT GROUP II GRADED
AGGREGATE BASE, SECTION 815*
12" RAW SUBGRADE COMPACTED
TO 90% OF LABORARY MAXIMUM
DENSITY (ASTM D 1557)
VARIES
DETAIL
NOT TO SCALE
CONCRETE SIDEWALK ADJACENT TO CURB
NOTES:
PROVIDE CONTRACTION (SAWED)
JOINTS AT INTERVALS NOT IN EXCESS
OF 6' O.C.
EXPANSION JOINTS SHALL BE PLACED
AS SHOWN ON THE PLANS OR AT 24'
INTERVALS IF NOT SHOWN.
SIDEWALK ADJACENT TO BUILDING TO
HAVE MINIMUM TRANSVERSE SLOPE OF
1% AWAY FROM BUILDING.
1/2 " EXPANSION JOINT MATERIAL AT ALL
LOCATIONS WHERE NEW CONCRETE ABUTS
EXISTING OR NEW STRUCTURES AND AT
ALL CHANGES IN DIRECTION OF SIDEWALK.
1.
2.
3.
4.
JOINT AND FINISH
CONCRETE SIDEWALK @ TURF OR
FLUSH WITH PAVEMENT AREAS
CONTRACTION JOINTCE EXPANSION JOINT
*GDOT: GEORGIA DEPARTMENT OF
TRANSPORTATION STANDARD
SPECIFICATIONS CONSTRUCTION
OF TRANSPORTATION SYSTEMS
WIDTH VARIES
SEE PLANS
WIDTH VARIES
SEE PLANS
3/8" 1/8" TO 1/4"
BROOMED FINISH
4" WIDE, SMOOTH
TROWELED PERIMETER
CONTRACTION JOINT
IN SIDEWALK ONLY
EXPANSION JOINT IN BOTH
CURB AND SIDEWALK
FLUSH AT
PAVED AREAS
12" RAW SUBGRADE COMPACTED
TO 90% OF LABORARY MAXIMUM
DENSITY (ASTM D 1557)
3/4" CHAMFER
IN TURF AREAS
FINISH GRADE
TURF AREAS
6"x6" W2.9xW2.9 WWF
4" GDOT GROUP II GRADED
AGGREGATE BASE, SECTION 815*
3/4" CHAMFER
IN TURF AREAS
FINISH GRADE
TURF AREAS
6"x6" W2.9xW2.9 WWF
4" GDOT GROUP II GRADED
AGGREGATE BASE, SECTION 815*
12" RAW SUBGRADE COMPACTED
TO 90% OF LABORARY MAXIMUM
DENSITY (ASTM D 1557)
1/4" PREMOLDED
JOINT FILLER
CURB REFER TO
DETAIL 2, SHEET
CS502.
PREMOLDED
JOINT FILLER
DETAIL
NOT TO SCALE
2 3
2"
6"x6" W2.9xW2.9 WWF
6"x6" W2.9xW2.9 WWF
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
PA
VE
M
EN
T D
ET
AI
LS
JU
LY
N U
1C S5
.d w g
CS501
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
(MIN.)
12"
0.02
0.02
0.02
12:1 24:1
12:1
24:1
12:1
NOTE:
SEE GDOT INDEX 304 FOR
FURTHER INFORMATION.
HANDICAP RAMP DETAIL
3'
SIDEWALK
TACTILE SURFACE
3' STD., 3'-8" WHEN
RAMP IS LOCATED
WITHIN 10' OF ANY BUILDING
DETAIL
NOT TO SCALE
1" R
1/2" R
6" R FLOW
THE COMPACTED SUBGRADE MAY CONSIST OF EARTH, SUBBASE
COURSE, GRANULAR FILTER COURSE, OR COMBINATIONS OF THESE
AS INDICATED.
6" CONCRETE CURB TO BE TAPERED OVER 10 FEET.
NOTE:
1.
2.
STANDARD 6" CURB AND GUTTER
24"
6"
6"1"
6"
FINISHED
GRADE
MATCH
EXISTING
PAVEMENT
EXISTING
BITUMINOUS
PAVEMENT
COMPACTED SUBGRADE
DETAIL
NOT TO SCALE
ISOMETRICSECTION
4"
4"
28"
24"
SIDEWALK DRAIN
DETAIL
NOT TO SCALE
2x2x1/4 ANGLE
WITH 1/4" STUDS
AT 12" OC
STAINLESS STEEL
SIDEWALK GRATING
2'-0"
2'-0"
6"x6" W2.9x2.9 WWF
#4@6" OCEW
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
PA
VE
M
EN
T D
ET
AI
LS
JU
LY
N U
1C S5
.d w g
CS502
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
2" GALV.PIPE
HANDRAIL
#4 REINFORCING
U BAR AT EACH POST
NON-SHRINK GROUT
4"Ø SLEEVE OR
CORE-DRILLED
1'-0"
12"
TREADS @ 12"
1'-0"
6"
1" TYP
#4 @ 6"
#4 @ 6"
2" GALV.PIPE
HANDRAIL BOTH
SIDES OF STAIRS
BROOMED FINISH
ON STAIR TREAD
#4 @ 6"
2-#5
2-#5 #4 @ 6"
#4 @ 6"
2-#5
1-#4 @ EA.
TREAD
1" R.
TYP.
1/2 " EXP. JT.
MATERIAL
1/2 " EXP. JT.
MATERIAL
4000 PSI
CONCRETE
CONCRETE STAIRS
DETAIL
NOT TO SCALE
4" TYP.
12"
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
M
IS
C
EL
LA
N
EO
U
S D
ET
AI
LS
JU
LY
N U
1C S5
.d w g
CS503
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
O
VE
R
AL
L G
R
AD
E
AN
D D
R
AI
N
PL
AN
N
40' 20' 0 40' 80' 120'
GRAPHIC SCALE: 1" = 40'
CG111
1. REFER TO SHEETCG701 THRU CG819 FOR EROSION AND
SEDIMENT CONTROL PLAN.
2. REFER TO SHEET C-001 FOR CIVIL LEGEND.
GENERAL GRADING NOTES
JU
LY
N U
1C G
1.
dw g
CG101
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
G R
AD
E
AN
D
D R
AI
N
P
LA
N
N
10' 5' 0 10' 20' 30'
GRAPHIC SCALE: 1" = 10'
SHEET KEYNOTES
1. PROVIDE BIO-RETENTION BASIN. REFER TO DETAIL 1,
SHEET CG501. TIE PERFORATED PIPE UNDERDRAIN INTO
DRY WELL.
2. MATCH EXISTING GRADE.
3. PROVIDE DRYWELL. REFER TO DETAIL 4, SHEET CG501.
2 22
LEGEND
STORM DRAIN CLEANOUT.
REFER TO DETAIL 2, SHEET CG501.
STORM DRAIN MANHOLE.
REFER TO DETAIL 3, SHEET CG501.
ROOF DRAIN. REFER TO DETAIL1,
SHEET CG502.
HEADWALL. REFER TO DETAIL 3,
SHEET CG502.
OUTLET PROTECTION. REFER TO
DETAIL ON SHEET CG817.
SPOT ELEVATIONS.
MAJOR CONTOUR.
MINOR CONTOUR.
CONSTRUCTION LIMITS.
ROOF DRAIN. REFER TO DETAIL 1,
SHEET CG502.
SD MH-01
CO-01
KEYMAP
HW-1
396.50
RD
N U
1C G
1.
dw g
CG111
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
Roof Drain
9+50 10+00 11+00 11+50
C O
-0
R
IM
: 3
.8
IN
V.
IN
: 3
.4
IN
V.
O
U T:
.4
C O
-0
R
IM
: 3
.8
IN
V.
IN
: 3
.5
IN
V.
O
U T:
.5
SD
M
H -0
R
IM
: 3
.8
IN
V.
IN
: 3
.7
IN
V.
O U
T:
.7
SD
M
H -0
R
IM
: 3
.8
IN
V.
IN
: 3
.2
IN
V.
O U
T:
.2
31.3 LF OF 15" SD @ 0.50%
32.5 LF OF 15" SD @ 0.50%
32.6 LF OF 15" SD @ 0.50%
10.5 LF OF 15" SD
@ 0.50%
PROPOSED
GROUND
INV: 393.22
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
R O
O F
D R
AI
N
P R
O
FI
LE
JU
LY
N U
1C G
1.
dw g
CG201
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
DETAIL
NOT TO SCALE
SURFACE FLOW
BIO-RETENTION BASIN
* “ENGINEERED SOIL” LAYER SHALL BE MINIMUM 18” DEEP “SANDY LOAM” SOIL MIX WITH NO MORE THAN 5% CLAY CONTENT. THE MIX SHALL CONTAIN 85-88% SAND, 8-12% SOIL FINES, AND 3-5%
ORGANIC MATTER.
18" MIN. ENGINEERED SOIL
*SEE NOTE BELOW
3" MIN OF PEA GRAVEL
NON-WOVEN GEOTEXTILE
4" PERFORATED PIPE UNDERDRAIN
NON-WOVEN
GEOTEXTILE
VA
R
IE
S
TO BUILDING
FROM BUILDING
SEE PLAN FOR
CONTINUATION
REFER TO PLAN FOR
CONTINUATION & SIZE
CLEANOUT
6"
1'
1'
1'
1'
6" RISER PIPE
CONCRETE
#3 BARS AT 8"
O. C. EACH WAY
BRASS CLEANOUT PLUG WITH
THREADED FERRULE. TOP
SURFACE OF PLUG SHALL BE SMOOTH
WHEN USED ON SIDEWALKS.
1" CHAMFER
FINISHED GRADE
REDUCER IF REQUIRED
DETAIL
NOT TO SCALE
STORM SEWER MANHOLE
PLAN-RING REINFORCING
ISOMETRIC VIEWSECTION
NOTE:
THIS IS A GENERAL
DETAIL. OPENINGS
ARE SHOWN IN THE
PLAN.
NOTE:
THIS MANHOLE IS FOR A
MAXIMUM 2'-3" INTERCEPTED
PIPE SIZE. LARGER PIPE
SIZES WILL REQUIRE A
DIFFERENT MANHOLE SIZE.
NOTE:
PRECAST MANHOLES TO MEET
ASTM C-478 AND H-20 LOADING.
2"
2"
1' -0
3"
5"
2'-0"
8' -0
" O R
L
ES
S
4'-0" 5"
RING 2'-4" DIA.
PRECAST OR
CAST-IN-PLACE
REFER TO SPECS
MORTAR BED
RINGS
CONCRETE FLOOR
#4@12" O.C.
A
RINGS 8 TIES
#4 BARS
DETAIL
NOT TO SCALE
D
FRAME
COVER
MANHOLE COVER AND FRAME
NOTE:
COVER FRAMES SHALL BE
SECURELY INSTALLED IN
A BED OF CEMENT MORTAR.
FRAME AND COVER TO BE
HEAVY DUTY TRAFFIC BEARING.
2'-0"
2'-1 3/4"
2" 1"
3/4" 8"
LARGE LETTER "S" CAST IN CENTER OF
COVER FOR SANITARY SEWER MANHOLE.
STORM MANHOLES TO HAVE "D" CAST IN COVER.
DETAIL
NOT TO SCALE
A
DRYWELL
CAP WITH CREW TOP LID
3'
DETAIL
NOT TO SCALE
FOOT PLATE
OBSERVATION WELL
NON-WOVEN GEOTEXTILE
(TOP AND SIDE ONLY)
TIE 4" PERFORATED PIPE
UNDERDRAIN INTO DRY WELL
BANK RUN GRAVEL
12"
REFER TO BIO-RETENTION
BASIN DETAIL THIS SHEET.
12" SAND LAYER
6"
NON-WOVEN GEOTEXTILE
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
G R
AD
E
AN
D
D R
AI
N
D
ET
AI
LS
JU
LY
N U
1C G
1.
dw g
CG501
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
TYPICAL UTILITY TRENCH
TURF PAVED
NOTE:
PIPE BEDDING AND
BACKFILL SHALL MEET
PIPE MANUFACTURER'S
REQUIREMENTS.
DIA. OF PIPE IN
IT
IA
L
C O
M
PA
C
TE
D
BA
C
KF
IL
L
SEED & PROTECTION
PLASTIC MARKING
TAPE SEE
SPECIFICATIONS.
PROVIDE NEAT SAWCUT
ON EACH SIDE OF TRENCH
AT EXISTING PAVEMENTS
PAVEMENT
PROVIDE NEW PAVEMENT
TO MATCH EXISTING.
COMPACTED SELECT GRANULAR BACKFILL.
SEE SPECIFICATIONS FOR DETAILS.
1'
SE
E
SP
EC
IF
IC
AT
IO
N S
C O
M
PA
C
TE
D B
AC
KF
IL
L
D +1
'-0
6" D /4
6" MIN
1'-6" MAX
DETAIL
NOT TO SCALE
VARIES
1%
PROFILE
PLAN
ROOF DRAIN
6" 45° PVC ELBOW
6" DIA. PVC PIPE
45° PVC WYE
PVC PIPE
BUILDING WALL DOWNSPOUT
CAST IRON DOWNSPOUT SHOE
(NEENAH R-4925-F OR APPROVED EQUAL)
FINISHED GRADE
MANUFACTURER'S STANDARD
TRANSITIONAL COUPLING
6" DIA. PVC PIPE
6" 90° PVC ELBOW
6" DIA. PVC PIPE 6" 45° PVC ELBOW
PVC PIPE
45° PVC WYEFOOTING
1 DETAIL
NOT TO SCALE
PIPE
SHAPEDIA. OR
EQUIV.
DIA.
DIMENSIONS
C E F L W T 12''
15''
18''
21''
24''
27''
815°+-
A A
PLAN VIEWSLOPE 5
SECTION A-A
1'-9''
2'-0''
1'-9''
2'-3''
3'-0''
2'-9''
2'-6''
2'-3''
2'-9''
2'-0''
2'-6''
2'-6''
2'-9''
3'-0''
3'-0''
3'-6''
3'-3''
3'-0''
3'-6''
4'-0''
3'-9''
4'-6''
2'-3''
2'-9''
2'-6''
3'-6''
3'-0''
4'-0''
3'-6''
4'-6''
4'-0''
5'-0''
4'-3''
3'-6''
4'-0''
3'-6''
4'-6''
4'-0''
5'-0''
5'-0''
4'-6''
5'-6''
6'-0''
5'-3''
4'-0''
4'-9''
4'-9''
5'-3''
5'-6''
6'-9''
6'-0''
6'-0''
6'-6''
7'-0''
7'-3''
2''
4''
2''
4''
3''
4''
2''
ISOMETRIC VIEW
30'' 31 2''
3'-3''
3'-0''
4'-0''
4'-9''
5'-6''
4'-9''
6'-6''
5'-9''
7'-6''
7'-9''
TYPICAL CONCRETE HEADWALL
NOTES
DIMENSIONS ARE BASED ON CONCRETE PIPE.
REINFORCING STEEL : MINIMUM GRADE 40, BARS
EVENLY SPACED.
6 - NO. 4 x 1'-0'' DOWEL BARS.
2 - NO. 4 x (E DIMENSION MINUS 4'').
SLOPES SHALL BE WARPED TO FIT HEADWALL WHEN PIPE
WING ANGLES AND/OR DIMENSIONS MAY BE ALTERED DURING
CONSTRUCTION TO ACCOMMODATE FLOW OF WATER.
APRON BETWEEN WINGS SHALL BE SLOPED IN DIRECTION
OF FLOW EQUAL TO SLOPE OF PIPE. FRONT FACE OF
HEADWALL SHALL REMAIN VERTICAL.
HEADWALLS ARE FOR CIRCULAR, ARCH, AND HORIZONTAL
ELLIPTICAL 12''- 27'' EQUIVALENT PIPE SIZES.
1.
2.
3.
4.
5.
6.
7.
8.
IS SKEWED AND/OR NORMAL SLOPE VARIES FROM 2:1.
CUT OFF TOE WALL
AT ROCK LINE WHEN
ENCOUNTERED.
CONSTRUCTION JT.
REQUIRED
E
F
8"
W
8"
1' -6
3"
8"
L 8"
T
T
8" T
C
3 DETAIL
NOT TO SCALE
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
G R
AD
E
AN
D
D R
AI
N
D
ET
AI
LS
JU
LY
N U
1C G
2.
dw g
CG502
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
ER
O
SI
O
N A
N D
S
ED
IM
EN
T C
O N
TR
O
L C
O
VE
R S
H
EE
T
US Army Corps of Engineers ®
Savannah District
FOR OFFICIAL USE ONLY
W912HN-20-B-3012
REPLACE COMPANY OPERATIONS BLDG'S
FORT BENNING, GEORGIA
FY19, PN 89006
SITE
JULY 2020
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
1.
2.
NAME: TITLE:
LEVEL II CERTIFICATION NUMBER:
SIGNATURE: DATE:
X
CIVIL ENGINEER
I CERTIFY UNDER PENALTY OF LAW THAT THIS ESPCP WAS PREPARED AFTER A SITE VISIT
TO THE LOCATIONS DESCRIBED HEREIN BY MYSELF OR MY AUTHORIZED AGENT, UNDER MY
DIRECT SUPERVISION.
NAME: TITLE:
LEVEL II CERTIFICATION NUMBER:
SIGNATURE: DATE:
CIVIL ENGINEER
OWNER: U.S. ARMY MANEUVER CENTER OF EXCELLENCE
DIRECTORATE OF PUBLIC WORKS (DPW), FORT BENNING
OWNER'S NAME: MR. CRAIG TAYLOR, DPW DIRECTOR
OWNER'S ADDRESS: 6650 MELOY DRIVE, BUILDING 6, ROOM 317
FORT BENNING, GA 31905
OWNER'S EMAIL: DONALD.C.TAYLOR50.CIV@MAIL.MIL
OWNER'S PHONE #: (706) 545-3155
OWNER FACILITY CONTACT NAME: SARA FORREST,
OWNER FACILITY CONTACT PHONE #: (706) 545-3604
OWNER FACILITY ADDRESS: IMBE-PWE-P CLEAN WATER ACT
MELOY DR, BLDG 6 RM 310
FORT BENNING, GA. 31905
OWNER FACILITY CONTACT EMAIL: SARA.A.FORREST.CIV@MAIL.MIL
NAME:
FIRM:
PHONE:
NOTE: IMPLEMENTATION OF THE ESPCP AND ALL REQUIREMENTS DESCRIBED HEREIN ARE THE
RESPONSIBILITY OF THE OPERATOR/CONTRACTOR (PRIMARY PERMITTEE) IDENTIFIED FOR THIS PROJECT, AS DELEGATED BY THE U.S. ARMY INFANTRY CENTER,DIRECTORATE OF PUBLIC WORKS, FORT BENNING UNDER CONTRACT.
"I CERTIFY UNDER PENALTY OF LAW THAT THIS DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY DIRECTION OR SUPERVISION IN ACCORDANCE WITH A SYSTEM DESIGNED TO ASSURE THAT CERTIFIED PERSONNEL PROPERLY GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED ON MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE SYSTEM, OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR GATHERING THE INFORMATION, THE INFORMATION SUBMITTED IS, TO THE BEST OF MY KNOWLEDGE AND BELIEF, TRUE, ACCURATE, AND COMPLETE. I AM AWARE THAT THERE ARE SIGNIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF
FINE AND IMPRISONMENT FOR KNOWING VIOLATIONS.
SIGNATURE: DATE:
SECTION V.G.2.d OF PERMIT
OPERATOR/CONTRACTOR INFORMATION:
PRIMARY PERMITTEE (OPERATOR/CONTRACTOR) INFORMATION:
24 HOUR OPERATOR CONTACT
EROSION CONTROL CERTIFICATION:
DESIGN PROFESSIONAL INSPECTION
GEOFFREY LYNN, PE
SIGNATURE: DATE OF INSPECTION:
GSWCC LEVEL 1A CERTIFICATION #:
COMPANY:
ADDRESS:
ADDRESS:
PHONE #:
FAX #:
NAME: TITLE:
GEOFFREY LYNN, PE
0000054173 (EXP. 06/05/2020)
0000054173 (EXP. 06/05/2020)
GEOFFREY LYNN, PE CIVIL ENGINEER
I CERTIFY THAT THE PERMITTEE'S EROSION, SEDIMENTATION AND POLLUTION CONTROL
PLAN (ESPCP) PROVIDES FOR AN APPROPRIATE AND COMPREHENSIVE SYSTEM OF BEST
MANAGEMENT PRACTICES REQUIRED BY THE GEORGIA WATER QUALITY CONTROL ACT AND THE
DOCUMENT "MANUAL FOR EROSION AND SEDIMENT CONTROL IN GEORGIA" (MANUAL)
PUBLISHED BY THE STATE SOIL AND WATER CONSERVATION COMMISSION AS OF JANUARY 1
OF THE YEAR IN WHICH LAND-DISTURBING ACTIVITY WAS PERMITTED, PROVIDES FOR THE
SAMPLING OF THE RECEIVING WATER(S) OR THE SAMPLING OF THE STORM WATER OUTFALLS
AND THAT THE DESIGNED SYSTEM OF BEST MANAGEMENT PRACTICES AND SAMPLING METHODS
IS EXPECTED TO MEET THE REQUIREMENTS CONTAINED IN THE GENERAL NPDES PERMIT NO.
GAR100001.
AS PER GAR 100001 - PART IV, A.5. AN INSPECTION OF THE INSTALLATION OF THE
INITIAL SEDIMENT STORAGE REQUIREMENTS AND PERIMETER CONTROL BMPS WHICH THE
DESIGN PROFESSIONAL DESIGNED WITHIN SEVEN (7) DAYS AFTER INSTALLATION. THE
DESIGN PROFESSIONAL SHALL DETERMINE IF THESE BMPS HAVE BEEN INSTALLED AND
ARE BEING MAINTAINED AS DESIGNED. THE DESIGN PROFESSIONAL SHALL REPORT THE
RESULTS OF THE INSPECTION TO THE PRIMARY PERMITTEE WITHIN SEVEN (7) DAYS AND
THE PERMITTEE MUST CORRECT ALL DEFICIENCIES WITHIN TWO (2) BUSINESS DAYS OF
RECEIPT OF THE INSPECTION REPORT FROM THE DESIGN PROFESSIONAL UNLESS WEATHER
RELATED SITE CONDITIONS ARE SUCH THAT ADDITIONAL TIME IS REQUIRED.
UNDER THE ABOVE CERTIFICATION, I, GEOFFREY A. LYNN, PE:
___ AGREE TO CONDUCT THE REQUIRED INSPECTION
___ AGREE AND DELEGATE TO THE FOLLOWING ALTERNATIVE DESIGN PROFESSIONAL
TO CONDUCT THE REQUIRED INSPECTION.
GPS PROJECT LOCATION
LATITUDE: 32°30'51"
LONGITUDE: - 84°50'10"
JU
LY
N U
1C G
0.
dw g
CG700
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
ER
O
SI
O
N C
O N
TR
O
L D
R
AW
IN
G
IN
D
EX
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 101
A
US Army Corps of Engineers
SHEET NUMBER SHEET TITLE
CG700 EROSION AND SEDIMENT CONTROL COVER SHEET
CG701 EROSION CONTROL DRAWING INDEX
CG702 LOCATION MAP
CG703 EROSION CONTROL CHECKLIST
CG704 EROSION CONTROL LEGEND
CG705 OVERALL INITIAL EROSION AND SEDIMENT CONTROL PLAN
CG711 INITIAL EROSION AND SEDIMENT CONTROL PLAN
CG712 INITIAL EROSION AND SEDIMENT CONTROL PLAN
CG721 INTERMEDIATE EROSION AND SEDIMENT CONTROL PLAN
CG722 INTERMEDIATE EROSION AND SEDIMENT CONTROL PLAN
CG731 FINAL EROSION AND SEDIMENT CONTROL PLAN
CG732 FINAL EROSION AND SEDIMENT CONTROL PLAN
CG750 PRE-CONSTRUCTION SITE HYDROLOGY
CG751 POST-CONSTRUCTION SITE HYDROLOGY
CG752 SOIL SERIES MAP
CG801 EROSION AND SEDIMENT CONTROL DETAILS
CG802 EROSION AND SEDIMENT CONTROL DETAILS
CG803 EROSION AND SEDIMENT CONTROL DETAILS
CG804 EROSION AND SEDIMENT CONTROL DETAILS
CG805 EROSION AND SEDIMENT CONTROL DETAILS
CG811 EROSION AND SEDIMENT CONTROL DETAILS
CG812 EROSION AND SEDIMENT CONTROL DETAILS
CG813 EROSION AND SEDIMENT CONTROL DETAILS
CG814 EROSION AND SEDIMENT CONTROL DETAILS
CG815 EROSION AND SEDIMENT CONTROL DETAILS
CG816 EROSION AND SEDIMENT CONTROL DETAILS
CG817 EROSION AND SEDIMENT CONTROL DETAILS
CG818 EROSION AND SEDIMENT CONTROL DETAILS
CG819 EROSION AND SEDIMENT CONTROL DETAILS
JU
LY
N U
1C G
1.
dw g
CG701
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
VICINITY MAP
NO SCALE
ATLANTA
FORT BENNING
COLUMBUS
MACON
AUGUSTA
SAVANNAH
ALBANY
STATE OF GEORGIA
NO SCALE
CONTRACTOR ENTRANCE
U.S. HIGHWAY 27/280
HAUL ROUTE
CUSSETA
CHATTAHOOCHEE
RIVER
G E O R G I A
MITCHELL
FORT
MILITARY
RESERVATION
FORT BENNING
COLUMBUS
PHENIX CITY
FLOURNOYS
FORT
MITCHELL
LAWSON
AAF
85 80
VESPER
IDA
CHATTAHOOCHEE
COUNTY
COMPANY OPERATIONS
BUILDING
PROJECT LOCATION
LO
C
AT
IO
N M
AP
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
US Army Corps of Engineers
C
AT
EG
O
R Y
C O
D E
D
ES
C R
IP
TI
O N
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JU
LY
N U
1C G
2.
dw g
CG702
W
2H N
-2 0-
B-
YN
N
M . S
O U
TH
J.
L
O C
K
M . P
O E
AN
SI
D
ISSUED FOR CONSTRUCTION
R
EP
LA
C
E C
O M
PA
N
Y O
PE
R
AT
IO
N S
BL
D
G 'S
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FY
, P
N
SI
TE
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
SA
VA
N N
AH
D
IS
TR
IC
T
1-
-0
8/
4/
SH
EE
T
R
EP
LA
C
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
PLAN
PAGE #
INCLUDED
Y/N ITEM
Y
Y
Y
PLAN
PAGE #
INCLUDED
Y/N ITEM
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
NA
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y * Y
Y * *Y
Y *
Y
Y
Y
*NA
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
NA
Y
Y
SWCD: PINE MOUNTAIN DISTRICT
Y
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
Y
CG704
CG701
CG801
CG701
CG700
CG801
CG700
ALL
CG801
CG703
CG801
CG700
CG701
CG701
CG801
CG802
CG802
CG802
CG802
CG802
CG801
CG801
CG818
CG801
CG801
CG811
CG804
CG803
CG804
CG803
CG804
CG804
CG750
CG751
ALL
ALL
ALL
CG802
ALL
CG750
CG750
CG751
CG752
CG752
CG811 -
CG818
CG811 -
CG813
CG814 -
CG818
CG801
THE APPLICABLE EROSION, SEDIMENTATION AND POLLUTION CONTROL PLAN CHECKLIST ESTABLISHED BY THE COMMISSION AS OF JANUARY 1 OF THE YEAR IN WHICH THE LAND-DISTURBING ACTIVITY WAS PERMITTED.
(THE COMPLETED CHECKLIST MUST BE SUBMITTED WITH THE ES&PC PLAN OR THE PLAN WILL NOT BE REVIEWED)
LEVEL II CERTIFICATION NUMBER ISSUED BY THE COMMISSION, SIGNATURE AND SEAL OF THE CERTIFIED DESIGN
PROFESSIONAL.
(SIGNATURE, SEAL AND LEVEL II NUMBER MUST BE ON EACH SHEET PERTAINING TO ES&PC PLAN OR THE PLAN WILL
NOT BE REVIEWED)
LIMITS OF DISTURBANCE SHALL BE NO GREATER THAN 50 ACRES AT ANY ONE TIME WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE EPD DISTRICT OFFICE. IF EPD APPROVES THE REQUEST TO DISTURB 50 ACRES OR MORE AT ANY ONE TIME, THE PLAN MUST INCLUDE AT LEAST 4 OF THE BMPs LISTED IN APPENDIX 1 OF THIS CHECKLIST (A COPY OF THE WRITTEN APPROVAL BY EPD MUST BE ATTACHED TO THE PLAN FOR THE PLAN TO BE REVIEWED)
THE NAME AND PHONE NUMBER OF THE 24-HOUR LOCAL CONTACT RESPONSIBLE FOR EROSION, SEDIMENTATION
AND POLLUTION CONTROLS.
PROVIDE THE NAME, EMAIL, ADDRESS AND PHONE NUMBER OF PRIMARY PERMITTEE.
NOTE TOTAL AND DISTURBED ACREAGE OF THE PROJECT OR PHASE UNDER CONSTRUCTION.
PROVIDE THE GPS LOCATION OF THE CONSTRUCTION EXIT FOR THE SITE. GIVE THE LATTITUDE AND LONGITUDE IN
DECIMAL DEGREES
INITIAL DATE OF THE PLAN AND THE DATES OF ANY REVISIONS MADE TO THE PLAN INCLUDING THE ENTITY WHO
REQUESTED THE REVISIONS.
DESCRIPTION OF THE NATURE OF THE CONSTRUCTION ACTIVITY.
PROVIDE VICINITY MAP SHOWING SITE'S RELATION TO SURROUNDING AREAS. INCLUDE DESIGNATION OF SPECIFIC
PHASE, IF NECESSARY.
IDENTIFY THE PROJECT RECEIVING WATERS AND DESCRIBE ALL SENSITIVE ADJACENT AREAS INCLUDING STREAMS, LAKES, RESIDENTIAL AREAS, WETLANDS, MARSHLANDS, ETC. WHICH MAY BE AFFECTED.
DESIGN PROFESSIONAL'S CERTIFICATION STATEMENT AND SIGNATURE THAT THE SITE WAS VISITED PRIOR TO
DEVELOPMENT OF THE ES&PC PLAN AS STATED ON PART IV, PAGE 19 OF THE PERMIT
DESIGN PROFESSIONAL'S CERTIFICATION STATEMENT AND SIGNATURE THAT THE PERMITTEE'S ES&PC PLAN PROVIDES FOR AN APPROPRIATE AND COMPREHENSIVE SYSTEM OF BMPs AND SAMPLING TO MEET PERMIT
REQUIREMENTS AS STATE ON PART IV, PAGE 19 OF THE PERMIT.
CLEARLY NOTE THE STATEMENT THAT "THE DESIGN PROFESSIONAL WHO PREPARED THE ES&PC IS TO INSPECT THE INSTALLATION OF THE INITIAL SEDIMENT STORAGE REQUIREMENTS AND PERIMETER CONTROL BMPs WITHIN 7 DAYS
AFTER INSTALLATION" IN ACCORDANCE WITH PARTIVE IV.A.5, PAGE 25 OF THE PERMIT.
CLEARLY NOTE THE STATEMENT THAT "NON-EXEMPT ACTIVITIES SHALL NOT BE CONDUCTED WITHIN 25 OR 50-FOOT UNDISTURBED STREAM BUFFERS AS MEASURED FROM THE POINT OF WRESTED VEGETATION OR WITHIN 25-FEET OF THE COASTAL MARSHLAND BUFFER AS MEASURED FROM THE JURISDICTIONAL DETERMINATION LINE WITHOUT FIRST
ACQUIRING THE NECESSARY VARIANCES AND PERMITS."
PROVIDE A DESCRIPTION OF ANY BUFFER ENCROACHMENTS AND INDICATE WHETHER A BUFFER VARIANCE IS
REQUIRED.
CLEARLY NOTE THE STATEMENT THAT "AMENDMENTS/REVISIONS TO THE ES&PC PLAN WHICH HAVE A SIGNIFICANT EFFECT ON BMPs WITH A HYDRAULIC COMPONENT MUST BE CERTIFIED BY THE DESIGN PROFESSIONAL."
CLEARLY NOTE THE STATEMENT THAT "WASTE MATERIALS SHALL NOT BE DISCHARGED TO WATERS OF THE STATE, EXCEPT AS AUTHORIZED BY A SECTION 404 PERMIT."
CLEARLY NOTE STATEMENT THAT "THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES PRIOR TO LAND DISTURBING
ACTIVITIES."
CLEARLY NOTE STATEMENT IN BOLD LETTERS - "EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES.
IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE FOR EFFECTIVE EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE
SEDIMENT SOURCE."
CLEARLY NOTE THE STATEMENT - "ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD GREATER THAN 14 DAYS
SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING."
ANY CONSTRUCTION ACTIVITY WHICH DISCHARGES STORM WATER INTO AN IMPAIRED STREAM SEGMENT, OR WITHIN 1 LINEAR MILE UPSTREAM OF AND WITHIN THE SAME WATERSHED AS, ANY PORTION OF A BIOTA IMPAIRED STREAM SEGMENT MUST COMPLY WITH PART III.C OF THE PERMIT. INCLUDE THE COMPLETED APPENDIX 1 LISTING ALL THE BMPs THAT WILL BE USED FOR THOSE AREAS OF THE SITE WHICH DISCHARGE TO THE IMPAIRED STREAM SEGMENT.
IF A TMDL IMPLEMENTATION PLAN FOR THE SEDIMENT HAS BEEN FINALIZED FOR THE IMPAIRED STREAM SEGMENT (IDENTIFIED IN ITEM 22 ABOVE) AT LEAST SIX MONTHS PRIOR TO SUBMITTAL OF NOI, THE ES&PC PLAN MUST ADDRESS ANY SITE-SPECIFIC CONDITIONS OR REQUIREMENTS INCLUDED IN THE TMDL IMPLEMENTATION PLAN.
BMPs FOR CONCRETE WASHDOWN OF TOOLS, CONCRETE MIXER CHUTES, HOPPERS AND THE REAR OF THE
VEHICLES. WASHOUT OF THE DRUM AT THE CONSTRUCTION SITE IS PROHIBITED.
PROVIDE BMPs FOR THE REMEDIATION OF ALL PETROLEUM SPILLS AND LEAKS.
DESCRIPTION OF THE MEASURES THAT WILL BE INSTALLED DURING THE CONSTRUCTION PROCESS TO CONTROL POLLUTANTS IN STORM WATER THAT WILL OCCUR AFTER CONSTRUCTION OPERATIONS HAVE BEEN COMPLETED.
DESCRIPTION OF PRACTICES TO PROVIDE COVER FOR BUILDING MATERIALS AND BUILDING PRODUCTS ON SITE.
DESCRIPTION OF THE PRACTICES THAT WILL BE USED TO REDUCE THE POLLUTANTS IN STORM WATER DISCHARGES.
DESCRIPTION AND CHART OR TIMELINE OF THE INTENDED SEQUENCE OF MAJOR ACTIVITIES WHICH DISTURB SOILS FOR THE MAJOR PORTIONS OF THE SITE (i.e. INITIAL PERIMETER AND SEDIMENT STORAGE BMPs, CLEARING AND GRUBBING ACTIVITIES, EXCAVATION ACTIVITIES, UTILITY ACTIVITIES, TEMPORARY AND FINAL STABILIZATION).
PROVIDE COMPLETE REQUIREMENTS OF INSPECTIONS AND RECORD KEEPING BY THE PRIMARY PERMITTEE.
CG801 Y
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
CG705
PROVIDE COMPLETE REQUIREMENTS OF SAMPLING FREQUENCY AND REPORTING OF SAMPLING RESULTS
PROVIDE COMPLETE DETAILS FOR RETENTION OF RECORDS AS PER PART IV.F. OF THE PERMIT.
DESCRIPTION OF ANALYTICAL METHODS TO BE USED TO COLLECT AND ANALYZE THE SAMPLES FROM EACH
LOCATION.
APPENDIX B RATIONALE FOR NTU VALUES AT ALL OUTFALL SAMPLING POINTS WHERE APPLICABLE.
DELINEATE ALL SAMPLING LOCATIONS, PERENNIAL AND INTERMITTENT STREAMS AND OTHER WATER BODIES INTO
WHICH STORM WATER IS DISCHARGED.
A DESCRIPTION OF APPROPRIATE CONTROLS AND MEASURES THAT WILL BE IMPLEMENTED AT THE CONSTRUCTION SITE INCLUDING: (1) INITIAL SEDIMENT STORAGE REQUIREMENTS AND PERIMETER CONTROL BMPs, (2) INTERMEDIATE GRADING AND DRAINAGE BMPs, AND (3) FINAL BMPs. FOR CONSTRUCTION SITES WHERE THERE WILL BE NO MASS GRADING AND THE INITIAL PERIMETER CONTROL BMPs, INTERMEDIATE GRADING AND DRAINAGE BMPs, AND FINAL BMPs ARE THE SAME THE PLAN MAY COMBINE ALL OF THE BMPs INTO A SINGLE PHASE
GRAPHIC SCALE AND NORTH ARROW.
EXISTING AND PROPOSED CONTOUR LINES WITH CONTOUR LINES DRAWN AT AN INTERVAL IN ACCORANCE WITH THE
FOLLOWING:
MAP SCALE GROUND SLOPE CONTOUR INTERVALS, FT
1 IN = 100 FT OR FLAT 0 - 2% 0.5 OR 1
LARGER SCALE ROLLING 2 - 8% 1 OR 2
STEEP 8% + 2, 5 OR 10
USE OF ALTERNATIVE BMPs WHOSE PERFORMANCE HAS BEEN DOCUMENTED TO BE EQUIVALENT TO OR SUPERIOR TO CONVENTIONAL BMPs AS CERTIFIED BY A DESIGN PROFESSIONAL (UNLESS DISAPPROVED BY EPD OR THE GEORGIA SOIL AND WATER CONSERVATION COMMISSION). PLEASE REFER TO THE ALTERNATIVE BMP GUIDANCE
DOCUMENT FOUND AT WWW.GASWCC.ORG.
USE OF ALTERNATIVE BMP FOR AAPLICATION TO THE EQUIVALENT BMP LIST. PLEASE REFER TO APPENDIX A-2 OF
THE MANUAL FOR EROSION & SEDIMENT CONTROL IN GEORGIA 2016 EDITION.
DELINEATION OF THE APPLICABLE 25-FOOT OR 50-FOOT UNDISTURBED BUFFERS ADJACENT TO STATE WATERS AND ANY ADDITIONAL BUFFERS REQUIRED BY THE LOCAL ISSUING AUTHORITY. CLEARLY NOTE AND DELINEATE ALL
AREAS OF IMPACT.
DELINEATION OF ON-SITE WETLANDS AND ALL STATE WATERS LOCATED ON AND WITHIN 200 FEET OF THE PROJECT
SITE.
DELINEATION AND ACREAGE OF CONTRIBUTING DRAINAGE BASINS ON THE PROJECT SITE.
PROVIDE HYDROLOGY STUDY AND MAPS OF DRAINAGE BASINS FOR BOTH THE PRE AND POST DEVELOPED
CONDITIONS
AN ESTIMATE OF THE RUNOFF COEFFICIENT OR PEAK DISCHARGE FLOW OF THE SITE PRIOR TO AND AFTER
CONSTRUCTION ACTIVITIES ARE COMPLETED.
STORM-DRAIN PIPE AND WEIR VELOCITIES WITH APPROPRIATE OUTLET PROTECTION TO ACCOMMODATE
DISCHARGES WITHOUT EROSION. IDENTIFY/DELINEATE ALL STORM WATER DISCHARGE POINTS.
SOIL SERIES FOR THE PROJECT SITE AND THEIR DELINEATION.
THE LIMITS OF DISTURBANCE FOR EACH PHASE OF CONSTRUCTION.
PROVIDE A MINIMUM OF 67 CUBIC YARDS OF SEDIMENT STORAGE PER ACRE DRAINED USING A TEMPORARY SEDIMENT BASIN, RETROFITTED DETENTION POND, AND/OR EXCAVATED INLET SEDIMENT TRAPS FOR EACH COMMON DRAINAGE LOCATION. SEDIMENT STORAGE VOLUME MUST BE IN PLACE PRIOR TO AND DURING ALL LAND DISTURBANCE ACTIVITIES UNTIL FINAL STABILIZATION OF THE SITE HAS BEEN ACHIEVED. A WRITTEN JUSTIFICATION EXPLAINING THE DECISION TO USE EQUIVALENT CONTROLS WHEN A SEDIMENT BASIN IS NOT ATTAINABLE MUST BE INCLUDED IN THE PLAN FOR EACH COMMON DRAINAGE LOCATION IN WHICH A SEDIMENT BASIN IS NOT PROVIDED. A WRITTEN JUSTIFICATION AS TO WHY 67 CUBIC YARDS OF STORAGE IS NOT ATTAINABLE MUST ALSO BE GIVEN.
WORKSHEETS FROM THE MANUAL MUST BE INCLUDED FOR STRUCTURAL BMPs AND ALL CALCULATIONS USED BY THE DESIGN PROFESSIONAL TO OBTAIN THE REQUIRED SEDIMENT STORAGE WHEN USING EQUIVALENT CONTROLS.
WHEN DISCHARGING FROM SEDIMENT BASINS AND IMPOUNDMENTS, PERMITTEES ARE REQUIRED TO UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE, UNLESS INFEASIBLE. IF OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE ARE NOT FEASABLE, A WRITTEN JUSTIFICATION EXPLAINING THIS DECISION
MUST BE INCLUDED IN THE PLAN.
LOCATION OF BEST MANAGEMENT PRACTICES THAT ARE CONSISTENT WITH AND NO LESS STRINGENT THAN THE MANUAL FOR EROSION AND SEDIMENT CONTROL IN GEORGIA. USE UNIFORM CODING SYMBOLS FROM THE MANUAL, CHAPTER 6, WITH LEGEND.
PROVIDE DETAILED DRAWINGS FOR ALL STRUCTURAL PRACTICES. SPECIFICATIONS MUST, AT A MINIMUM, MEET THE
GUIDELINES SET FORTH IN THE MANUAL FOR EROSION AND SEDIMENT CONTROL IN GEORGIA.
PROVIDE VEGETATIVE PLAN, NOTING ALL TEMPORARY AND PERMANENT VEGETATIVE PRACTICES. INCLUDE SPECIES, PLANTING DATES AND SEEDING, FERTILIZER, LIME AND MULCHING RATES. VEGETATIVE PLAN SHALL BE SITE SPECIFIC FOR APPROPRIATE TIME OF YEAR THAT SEEDING WILL TAKE PLACE AND FOR THE APPROPRIATE
GEOGRAPHIC REGION OF GEORGIA.
IF USING THIS CHECKLIST FOR A PROJECT THAT IS LESS THANK 1 ACRE AND
NOT PART OF A COMMON DEVELOPMENT BUT WITHIN 200 FT OF A PERENNIAL
STREAM THE CHECKLIST ITEMS WOULD BE NOT APPLICABLE. EFFECTIVE
JANUARY 1, 2020.
CG711, CG721
CG731
EROSION, SEDIMENTATION & POLLUTION CONTROL PLAN CHECKLIST STAND ALONE CONSTRUCTION PROJECTS
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
FI
LE
N
AM
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
A
M
AR
K
SI
This is the start of the file's text. The full file is on GovTribe.