W912HN-18-B-3001_VOL2_AMD4.pdf
PDF 5 MB Posted
- Solicitation number
- W912HN18B3001
About this file
Drawings Vol 2 Amd 4
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B.01.02_Bid_Abstract_W912HN18B3001_ARCYBER_COF.xls | XLS spreadsheet | |
| Bid_Abstract_W912HN18B3001_ARCYBER_COF.pdf | ||
| 18B3001vol2.PDF | ||
| 18B3001vol1.PDF | ||
| amd7.pdf | ||
| amd6.pdf | ||
| 18B3001vol1.PDF | ||
| amd5.pdf | ||
| 18B3001vol1.PDF | ||
| 18B3001vol2.PDF | ||
| 18B3001vol4.PDF | ||
| 18B3001vol3.PDF | ||
| W912HN-18-B-3001_VOL2_AMD5.pdf | ||
| 18B3001vol1.pdf | ||
| 18B3001vol3.pdf | ||
| 18B3001vol4.pdf | ||
| 18B3001vol2.pdf | ||
| amd4.pdf | ||
| W912HN-18-B-3001_VOL2_AMD3.pdf | ||
| 18B3001vol1.pdf | ||
| amd3.pdf | ||
| W912HN-18-B-3001_VOL1_AMD3.pdf | ||
| 18B3001vol2.pdf | ||
| amd2.pdf | ||
| W912HN-18-B-3001_VOL1_AMD1.pdf | ||
| 18B3001vol4.pdf | ||
| W912HN-18-B-3001_VOL2_AMD2.pdf | ||
| 18B3001vol1.pdf | ||
| 18B3001vol1.pdf | ||
| amd1.pdf | ||
| 18B3001vol3.pdf | ||
| 18B3001vol4.pdf | ||
| 18B3001vol2.pdf | ||
| W912HN-18-B-3001_VOL1.pdf | ||
| W912HN-18-B-3001_VOL2.pdf | ||
| 18B3001vol1.pdf |
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID. TITLE
INDEX OF DRAWINGS - VOLUME 2
SHEET ID. SHEET ID.TITLE TITLE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY17PN85794_PROJ_R18_K6ENDKRW.rvt
6/28/2018 12:54:41 PM
AP
R
IL
W
2H N
-1 8-
B-
XX
X
YY
Y
Au th or
XX
X
YY
Y
1-
-0
G-002
IN
D
EX
O
F D
R
AW
IN
G
S
Sa va nn ah
, G eo rg ia
Sa va nn ah
, G eo rg ia
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
XX
X
YY
Y
ISSUED FOR CONSTRUCTION
MH603 MECHANICAL SCHEDULES
MH701 HOT AND CHILLED WATER PIPING SCHEMATIC
MI001 HVAC CONTROLS LEGEND
MI002 HVAC CONTROLS POINTS - SCHEDULING INSTRUCTIONS
MI801 AHU-1 CONTROL SCHEMATIC AND LADDER DIAGRAM
MI802 AHU-2 & 3 CONTROL SCHEMATIC AND LADDER DIAGRAM
MI803 AHU-4 CONTROL SCHEMATIC AND LADDER DIAGRAM
MI804 DOAS-1 CONTROL SCHEMATIC AND LADDER DIAGRAM
MI804A ERV-1 & 2 CONTROL SCHEMATIC AND LADDER DIAGRAM
MI805 AHU-1 SEQUENCE-OF-OPERATION
MI806 AHU-2 & 3 SEQUENCE-OF-OPERATION
MI807 AHU-4 SEQUENCE-OF-OPERATION
MI808 DOAS-1 SEQUENCE-OF-OPERATION
MI808A ERV-1 & 2 SEQUENCE OF OPERATION
MI809 CONTROL VALVE & CONTROL DAMPER SCHEDULES
MI810 AHU-1 CONTROL POINTS SCHEDULE
MI811 AHU-2 & 3 CONTROL POINTS SCHEDULE
MI812 AHU-4 CONTROL POINTS SCHEDULE
MI813 DOAS-1 CONTROL POINTS SCHEDULE
MI814 MISC CONTROL SCHEMATICS
MI815 MISC CONTROLS AND SEQUENCE-OF-OPERATION
MI816 VAV TERMINAL UNIT & UNIT HEATER CONTROL POINTS SCHEDULE
MI817 MISC CONTROL POINTS SCHEDULES
MI818 FCU-1 & 2 CONTROL POINTS SCHEDULE
MI819 HYDRONIC HEATING HOT WATER SYSTEM CONTROL SCHEMATIC AND SEQUENCE-OF-OPERATION
MI820 HYDRONIC CHILLED WATER SYSTEM CONTROL SCHEMATIC AND SEQUENCE-OF-OPERATION
MI821 HYDRONIC CHILLED WATER SYSTEM CONTROL POINTS SCHEDULE
MI822 HYDRONIC HEATING HOT WATER SYSTEM CONTROL POINTS SCHEDULE
MI823 DOMESTIC HOT WATER CTRL SCHEMATIC, SEQUENCE OF OP, AND CTRL POINTS SCHED
MP101 HVAC HYDRONIC PIPING PLAN
MP102 HVAC HYDRONIC PIPING PLAN - PARTS A & C
MP103 HVAC HYDRONIC PIPING PLAN - PARTS B & D
E-001 ELECTRICAL LEGEND & GENERAL NOTES
E-002 ELECTRICAL ABBREVIATIONS & MOUNTING DIAGRAM
EG101 LIGHTNING PROTECTION PLAN - PARTS A & C
EG102 LIGHTNING PROTECTION PLAN - PARTS B & D
EG103 GROUNDING PLAN - PARTS A & C
EG104 GROUNDING PLAN - PARTS B & D
EG501 LIGHTNING PROTECTION SYSTEM DETAILS
EG502 MISCELLANEOUS GROUNDING DETAILS
EL101 LIGHTING PLAN - PARTS A & C
EL102 LIGHTING PLAN - PARTS B & D
EL401 LIGHTING PLAN - ENLARGED MECHANICAL EQUIPMENT PLATFORM
EL501 LIGHT FIXTURE SCHEDULE AND DETAILS
EL502 LIGHT FIXTURE DETAILS
EL503 LIGHT FIXTURE DETAILS
EL504 NOT USED
EL601 LIGHTING CONTROL STRATEGIES AND DETAILS
EP101 POWER PLAN - PARTS A & C
EP102 POWER PLAN - PARTS B & D
EP103 EQUIPMENT POWER PLAN - PARTS A & C
EP104 EQUIPMENT POWER PLAN - PARTS B & D
EP105 ROOF POWER PLAN - PARTS A & C
EP106 ROOF POWER PLAN - PARTS B & D
EP401 ENLARGED POWER PLANS
EP501 ELECTRICAL DETAILS
EP601 POWER ONE-LINE DIAGRAM
EP602 FEEDER & TRANSFORMER SCHEDULES
EP603 PANEL SCHEDULES
EP604 PANEL SCHEDULES
EP605 PANEL SCHEDULES
EP606 PANEL SCHEDULES
EP607 PANEL SCHEDULES
EY001 AUXILIARY SYSTEMS LEGEND & GENERAL NOTES
EY101 AUXILIARY SYSTEMS PLAN - PARTS A & C
EY102 AUXILIARY SYSTEMS PLAN - PARTS B & D
EY601 AUXILIARY SYSTEMS DIAGRAMS
T-001 TELECOMMUNICATIONS LEGEND & GENERAL NOTES
T-101 TELECOMMUNICATION PLAN - PARTS A & C
T-102 TELECOMMUNICATION PLAN - PARTS B & D
T-103 TELECOMMUNICATION NON-SECURE PATHWAY PLAN - PARTS A & C
T-104 TELECOMMUNICATION NON-SECURE PATHWAY PLAN - PARTS B & D
T-105 SIPRNET PATHWAY PLAN - PARTS A & C
T-106 SIPRNET PATHWAY PLAN - PARTS B & D
T-401 ENLARGED TELECOMMUNICATION PLANS
T-501 TELECOMMUNICATION DETAILS - CABLE TRAYS
T-502 TELECOMMUNICATION DETAILS - OUTLETS & LABELING
T-601 TELECOMMUNICATION ONE-LINE DIAGRAMS
T-602 TELECOMMUNICATION ELEVATION DIAGRAM - T.E.R. B103
T-603 TELECOMMUNICATION ELEVATION DIAGRAM - T.R. B116
T-604 TELECOMMUNICATION ELEVATION DIAGRAM - NERD SERVER C102
A-602 PARTITION TYPES
A-603 DOOR SCHEDULE AND DETAILS 1
A-604 DOOR SCHEDULE AND DETAILS 2
A-604A ESS DOOR DETAILS 1
A-604B ESS DOOR DETAILS 2
A-604C ESS DOOR DETAILS 3
A-605 DOOR DETAILS
A-606 DOOR DETAILS
A-607 DOOR DETAILS
A-608 WINDOW TYPES
A-609 WINDOW DETAILS 1
A-609A WINDOW DETAILS 2
A-610 LOUVER SCHEDULE AND LOUVER DETAILS
A-620 FINISH SCHEDULE
A-701 LIFE SAFETY PLAN
A-702 LIFE SAFETY ANALYSIS
A-800 AIR BARRIER BOUNDARY PLAN
A-801 AIR BARRIER SECTIONS
A-802 AIR BARRIER DETAILS 1
A-803 AIR BARRIER DETAILS 2
A-804 AIR BARRIER DETAILS 3
A-805 AIR BARRIER DETAILS 4
A-806 AIR BARRIER DETAILS 5
I-101A FURNITURE PLAN - AREA A
I-101B FURNITURE PLAN - AREA B
I-101C FURNITURE PLAN - AREA C
I-101D FURNITURE PLAN - AREA D
I-111A FINISH PLAN - AREA A
I-111B FINISH PLAN - AREA B
I-111C FINISH PLAN - AREA C
I-111D FINISH PLAN - AREA D
I-501 SIGNAGE SCHEDULE & DETAILS
I-511 SIGNAGE TYPICALS 1
I-512 SIGNAGE TYPICALS 2
I-601 ROOM FINISH SCHEDULE
I-611 FINISH LEGEND
I-612 FINISH DETAILS
FA001 FIRE ALARM LEGEND AND OPERATIONS MATRIX
FA101 FIRE ALARM & MASS NOTIFICATION SYSTEMS PLAN - PARTS A & C
FA102 FIRE ALARM & MASS NOTIFICATION SYSTEMS PLAN - PARTS B & D
FA601 FIRE ALARM & MNS ONE-LINE DIAGRAM
FX001 FIRE PROTECTION LEGEND AND GENERAL NOTES
FX101 FIRE PROTECTION FLOOR PLAN - OVERALL
FX102 FIRE PROTECTION FLOOR PLAN - AREA A
FX103 FIRE PROTECTION FLOOR PLAN - AREA B
FX104 FIRE PROTECTION FLOOR PLAN - AREA C
FX105 FIRE PROTECTION FLOOR PLAN - AREA D
FX501 FIRE PROTECTION DETAILS I
FX502 FIRE PROTECTION DETAILS II
FX503 FIRE PROTECTION DETAILS III
P-001 PLUMBING LEGEND
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-503 PLUMBING DETAILS
P-504 PLUMBING DETAILS
PL101 PLUMBING FLOOR PLAN - SANITARY SEWER
PL102 PLUMBING FLOOR PLAN - DOMESTIC WATER
PL103 PLUMBING FLOOR PLAN - ROOF DRAINAGE
PL601 PLUMBING SCHEDULES
M-001 HVAC LEGEND
MH101 HVAC FLOOR PLAN - OVERALL
MH102 HVAC FLOOR PLAN - PARTS A & C
MH103 HVAC FLOOR PLAN - PARTS B & D
MH104 HVAC FLOOR PLAN - PARTS A & C (AIRFLOWS & DEVICES)
MH105 HVAC FLOOR PLAN - PARTS B & D (AIRFLOWS & DEVICES)
MH106 HVAC ROOF PLAN
MH107 HVAC THERMOSTAT & SENSOR PLAN
MH301 HVAC SECTIONS
MH302 HVAC SECTIONS
MH303 HVAC SECTIONS
MH304 HVAC SECTIONS
MH305 HVAC SECTIONS
MH401 HVAC ENLARGED PLANS
MH501 HVAC DETAILS
MH502 HVAC DETAILS
MH503 HVAC DETAILS
MH504 HVAC DETAILS
MH505 HVAC DETAILS
MH506 HVAC BRACING DETAILS
MH507 HVAC DETAILS
MH601 MECHANICAL SCHEDULES
MH602 MECHANICAL SCHEDULES
G-001 COVER SHEET
G-002 INDEX OF DRAWINGS
G-003 GENERAL NOTES, ABBREVIATIONS
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
S-003 GENERAL STRUCTURAL NOTES
SB101 COMPOSITE FOUNDATION PLAN
SB101A FOUNDATION PLAN - AREA A
SB101B FOUNDATION PLAN - AREA B
SB101C FOUNDATION PLAN - AREA C
SB101D FOUNDATION PLAN - AREA D
SB102 LOADING DOCK PLAN
SB103 PEDESTRIAN BRIDGE PLAN
SB301 FOUNDATION SECTIONS
SB302 FOUNDATION SECTIONS
SB303 FOUNDATION SECTIONS
SB501 FOUNDATION DETAILS
SB601 FOUNDATION SCHEDULES
SF101 COMPOSITE ROOF PLAN
SF101A ROOF PLAN - AREA A AND C
SF101B ROOF PLAN - AREA B AND D
SF201 FRAMING ELEVATIONS
SF202 FRAMING ELEVATIONS
SF203 FRAMING ELEVATIONS
SF204 FRAMING ELEVATIONS
SF205 FRAMING ELEVATIONS
SF206 FRAMING ELEVATIONS
SF207 FRAMING ELEVATIONS
SF208 FRAMING ELEVATIONS
SF301 FRAMING SECTIONS
SF302 FRAMING SECTIONS
SF303 FRAMING SECTIONS
SF304 FRAMING SECTIONS
SF305 FRAMING SECTIONS
SF501 FRAMING DETAILS
SF502 FRAMING DETAILS
SF601 COLUMN SCHEDULES
A-101 COMPOSITE FLOOR PLAN
A-101A FLOOR PLAN -AREA A
A-101B FLOOR PLAN -AREA B
A-101C FLOOR PLAN -AREA C
A-101D FLOOR PLAN -AREA D
A-101E FLOOR PLAN - MECHANICAL EQUIPMENT PLATFORMS AREA C & D
A-101F CLERESTORY PLAN
A-102 DIMENSION PLAN
A-102A DIMENSION PLAN- LATRINES/BREAKROOM
A-103 SECRET OPEN STORAGE AREA FLOOR PLAN
A-104 ROOF PLAN
A-105 REFLECTED CEILING PLAN -PART A
A-106 REFLECTED CEILING PLAN -PART B
A-107 REFLECTED CEILING PLAN -PART C
A-108 REFLECTED CEILING PLAN -PART D
A-109 REFLECTED CEILING PLAN - MECH. EQUIPMENT PLATFORM AREAS C & D
A-201 NORTH ELEVATIONS PART A AND B
A-202 SOUTH ELEVATIONS PART C AND D
A-203 EAST AND WEST ELEVATIONS
A-301 BUILDING CROSS SECTION
A-302 BUILDING LONGITUDINAL SECTION
A-310 WALL SECTIONS
A-311 WALL SECTIONS
A-312 WALL SECTIONS
A-313 WALL SECTIONS
A-314 WALL SECTIONS
A-315 WALL SECTIONS
A-316 WALL SECTIONS
A-317 WALL SECTIONS
A-400 ENLARGED PLANS & INTERIOR ELEVATIONS
A-401 ENLARGED PLANS & INTERIOR ELEVATIONS
A-500 ROOF DETAILS 1
A-501 ROOF DETAILS 2
A-502 ROOF DETAILS 3
A-503 ROOF DETAILS 4
A-504 ROOF DETAILS 5
A-520 CEILING DETAILS
A-521 INTERIOR DETAILS I
A-522 INTERIOR DETAILS 2
A-523 INTERIOR DETAILS 3
A-530 EXTERIOR DETAILS
A-531 EXTERIOR DETAILS 2
A-540 MISCELLANEOUS DETAILS
A-601 PARTITION TYPES
A-601A PARTITION TYPES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 8
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 8
B
9 10
C
PTDWR
LPS
SD
SD
MG
MG
PTDWR
LPS LPS
LB
SCSCR
TP TP
SCSCR
SCSCR
TPADA
SHSH SH
GB03 FSS
TTD TTD TTD TTD
TSCD TSCDTSCD
GB02
GB01
TSCD
A-400
7 9
A-400
SND SND SND SND
B
C
LPS
LPS LPS
LPSLB
PTDWR
SCSCR SCSCR SCSCR SCSCR
TP TP TPSH
FSS
GB03
SH SH SH
PTDWR
PTDWR
SD
MG
MG
SD
MG
SD
MG
MG
TPABA
TTD TTD TTD TTD
TTD TTD TTD TTD
GB01
GB02TSCD TSCD TSCD TSCD
A-401 64
A-401
9 10 11
SMHD
A-401
A-401
D
6 87
SMHD
SMHD
A-401
A-401
1. SLOPE SLABS TO FLOOR DRAINS, TYP.
2. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL
TOILET ACCESSORIES.
3. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL
WALL HUNG FIXTURES (LAVATORIES, URINALS, ETC.).
4. WOMEN'S & MEN'S SHOWER AREAS SHALL BE FULL HEIGHT CERAMIC
WALL TILE AS INDICATED. ALL OTHER AREAS SHALL HAVE A 4'-0" WALL TILE
WAINSCOT, TYP. TERMINATE THE 4'-0" HIGH CERAMIC WALL TILE WAINSCOT
WITH A BULLNOSE.
1. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN
CENTERLINES, UNLESS NOTED OTHERWISE (U.N.O.).
2. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.
3. REFERENCE SHEETS A-601, A-601A & A- A-602 FOR PARTITION TYPES.
4. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR
TYPICAL TILE SIZE AND PATTERNS.
B.O. REFLECTIVE
SURFACE
MG
TOWEL
PIN
(TPABA)
SHOWER
CURTAIN &
ROD
(SCSR)
24" X 36"
MIRROR (MG)
FOLDING
SHOWER
SEAT (FSS1)
SHOWER HEAD
AND HAND HELD
UNIT
SURFACE MOUNTED
GRAB BARS FOR
SHOWER (GB03)
WATER CLOSET AND
GRAB BARS (GB01)
(GB02)
WATER CLOSET AND
GRAB BARS (GB01) (GB02)
WALL-MOUNTED
LAVATORY
HC- ABA
COMPLIANT
TTD
SOAP
DISPENSE
R
(SD)
SOAP
DISH
(SH)
WATER
COOLER
ACCESSIBLE / BI-LEVEL ELECTRIC
WATER COOLER (INSTALL BOTTLE
FILLER WITHIN ACCESSIBLE
REACH)
LAVATORYSANITARY
NAPKIN
DISPOSAL (SND)
SND
SND
3' -4
" M
AX
2' -1
0"
2' -3
9"
8" 7"
4' -0
/2
3' -4
" T O
BO
TT
O M
O F
R
EF
LE
C
TI
VE
SU
R
FA
C
E
" M
IN
. T
O
" M
AX
. A
.F .F
6' -6
18" MIN.
40"-42" MAX.
2' -0
"-1
9"
"-1
9"
17" MIN.
" M
AX
" M
IN
6" MAX.
3' -0
1'-2" 1' -5
M
AX
6" MAX 8" MIN.
17"-19"
3' -3
2' -9
9" M
IN
2' -6
4' -0
18" TYP.
CONTROL
S
UG
TOILET SEAT COVER
DISPENSER (TSCD)
URINALS
1'-2" 1' -1
1"
TOWEL
PIN
(TP)
5' -0
HC- ABA
COMPLIAN
T
PAPER TOWEL
DISPENSER / WASTE
RECEPTACLE (PTD)
4' -0
M
AX
1' - 0" MAX. 3' - 6" MIN.
1'
3/
4"
UTILITY SHELF WITH
RAG HOOKS AND
BROOM HOLDERS
(SMHD)
5'
6"
1' - 0"
2"
CENTERLINE
OF SHOWER
SEAT
7 1/2"
3'
6"
4'
0"
LPSLPS LPS
PTDWR
LB
4" HIGH CONCRETE BASE WITH TILE FINISH
ON EACH EXPOSED FACE
9'
0"
4'
0"
FSS SCSCR SCSCR SCSCR
TPADA
SH
TP
SH
TP
SCSCRSCSCR SCSCR
SD
MG
4'
0"
9'
0"
MG MG MG
SD SD
4'
0"
9'
0"
PTDWR
9'
0"
4'
0"
PTDWR
9'
0"
4'
0"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt
6/27/2018 5:28:59 PM
AP
R
IL
W
2H N
-1 8-
B-
P.
S
U
LL
IV
AN
Au th or
T.
D
C
AT
C
O D
E
A-400
EN
LA
R G
ED
P
LA
N
S
IN
TE
R
IO
R E
LE
VA
TI
O
N S
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
XX
X
YY
Y
ISSUED FOR CONSTRUCTION
WOMENS ROOM B1051 MENS ROOM B1082
BREAKROOM B107/JANITORS CLOSET B1113 JANITORS CLOSETS C101 AND D1034
GENERAL NOTES
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
TOILET & FIXTURE ACCESSORIES SCHEDULE
Accessory Description Type Mark MOUNTING HEIGHT
FOLDING ADA SHOWER SEAT FSS SEE DETAILS FOR
MOUNTING HEIGHT
GRAB BAR 36" GB01 34" A.F.F. CENTERLINE
OF BAR
Grab Bars 42" GB02 34" A.F.F. centerline of bar
ABA 1 1/2" DIA. STAINLESS STEEL
HORIZONTAL TWO WALL BAR
GB03 34" A.F.F. CENTERLINE
OF BAR
SOLID PLASTIC PEDESTAL BENCH LB
Personal Storage Locker - Single Door LPS 12" X 15" X 72" SLOPED
TOP
18"W 36"H MIRROR WITH STAINLESS
STEEL FRAME
MG BOTTOM OF GLASS 40"
AFF
SEMI-RECESSED PAPER TOWEL
DISPENSER WASTE RECEPTACLE
PTDWR 48" A.F.F.
SHOWER CURTAIN & ROD SCSCR
WALL MOUNTED SOAP DISPENSER SD TOP 46" A.F.F.
SOAP HOLDER SH TOP 40' A.F.F.
UTILITY SHELF WITH RAG HOOKS
AND BROOM HOLDERS
SMHD 66" A.F.F.
SANITARY NAPKIN DISPOSER SND SURFACE MOUNTED
TOP 30" A.F.F.
TOWEL PIN TP 66" A.F.F.
TOWEL PIN ABA TPABA 44 A.F.F.
TOWEL PIN ADA TPADA
TOILET SEAT COVER DISPENSER -
SURFACE
TSCD 48" A.F.F.
TOILET TISSUE DISPENSER - 2 ROLL,
SURFACE
TTD 20" A.F.F
DRAWING NOTES
WOMENS ROOM B105 ELEV. A5 WOMENS ROOM B105 ELEV. B6
WOMENS ROOM B105 ELEV. C7
WOMENS ROOM B105 ELEV. D8
WOMENS ROOM B105 ELEV. E9
WOMENS ROOM B105 ELEV. F10
FIXTURE MOUNTING HEIGHTS
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 9
1. SLOPE SLABS TO FLOOR DRAINS, TYP.
2. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL
TOILET ACCESSORIES.
3. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL
WALL HUNG FIXTURES (LAVATORIES, URINALS, ETC.).
4. WOMEN'S & MEN'S SHOWER AREAS SHALL BE FULL HEIGHT CERAMIC
WALL TILE AS INDICATED. ALL OTHER AREAS SHALL HAVE A 4'-0" WALL TILE
WAINSCOT, TYP. TERMINATE THE 4'-0" HIGH CERAMIC WALL TILE WAINSCOT
WITH A BULLNOSE.
B.O. REFLECTIVE
SURFACE
MG
TOWEL
PIN
(TPABA)
SHOWER
CURTAIN &
ROD
(SCSR)
24" X 36"
MIRROR (MG)
FOLDING
SHOWER
SEAT (FSS1)
SHOWER HEAD
AND HAND HELD
UNIT
SURFACE MOUNTED
GRAB BARS FOR
SHOWER (GB03)
WATER CLOSET AND
GRAB BARS (GB01)
(GB02)
WATER CLOSET AND
GRAB BARS (GB01) (GB02)
WALL-MOUNTED
LAVATORY
HC- ABA
COMPLIANT
TTD
SOAP
DISPENSE
R
(SD)
SOAP
DISH
(SH)
WATER
COOLER
ACCESSIBLE / BI-LEVEL ELECTRIC
WATER COOLER (INSTALL BOTTLE
FILLER WITHIN ACCESSIBLE
REACH)
LAVATORYSANITARY
NAPKIN
DISPOSAL (SND)
SND
SND
3' -4
" M
AX
2' -1
0"
2' -3
9"
8" 7"
4' -0
/2
3' -4
" T O
BO
TT
O M
O F
R
EF
LE
C
TI
VE
SU
R
FA
C
E
" M
IN
. T
" M
AX
. A
.F .F
6' -6
18" MIN.
40"-42" MAX.
2' -0
"-1
9"
"-1
9"
17" MIN.
" M
AX
" M
IN
6" MAX.
3' -0
1'-2" 1' -5
M
AX
6" MAX 8" MIN.
17"-19"
3' -3
2' -9
9" M
IN
2' -6
4' -0
18" TYP.
CONTROL
S
UG
TOILET SEAT COVER
DISPENSER (TSCD)
URINALS
1'-2" 1' -1
1"
TOWEL
PIN
(TP)
5' -0
HC- ABA
COMPLIAN
T
PAPER TOWEL
DISPENSER / WASTE
RECEPTACLE (PTD)
4' -0
M
AX
1' - 0" MAX. 3' - 6" MIN.
1'
3/
4"
UTILITY SHELF WITH
RAG HOOKS AND
BROOM HOLDERS
(SMHD)
5'
6"
1' - 0"
2"
CENTERLINE
OF SHOWER
SEAT
7 1/2"
3'
6"
1. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN
CENTERLINES, UNLESS NOTED OTHERWISE (U.N.O.).
2. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.
3. REFERENCE SHEETS A-601, A-601A & A- A-602 FOR PARTITION TYPES.
4. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR
TYPICAL TILE SIZE AND PATTERNS.
LPS
LPS LPS
LPS
LB
PTDWR
MG
SD
4'
0"
9'
0"
4" HIGH CONCRETE BASE WITH TILE FINISH
ON EACH EXPOSED FACE
4'
0"
9'
0" MG
SD PTDWR
SCSCR SCSCR SCSCR SCSCR
TP TP TP
TPABA
SHSHSH
FSS
4'
0"
9'
0"
PTDWR
PTDWR
SD
PTDWR PTDWR
PTDWR
4'
0"
9'
0"
MG MG MG MG MG
SD SD SDSD
PTDWR
4'
0"
9'
0"
A-540
A-540
A-540
8'
0"
SMHD
D
SMHD
8'
0"
SMHD
8'
0"
A-801
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt
6/27/2018 5:29:08 PM
AP
R
IL
W
2H N
-1 8-
B-
P.
S
U
LL
IV
AN
Au th or
T.
D
C
AT
C
O D
E
A-401
EN
LA
R G
ED
P
LA
N
S
IN
TE
R
IO
R E
LE
VA
TI
O
N S
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
C he ck er
ISSUED FOR CONSTRUCTION
GENERAL NOTES
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
DRAWING NOTES
TOILET & FIXTURE ACCESSORIES SCHEDULE
Accessory Description Type Mark MOUNTING HEIGHT
FOLDING ADA SHOWER SEAT FSS SEE DETAILS FOR
MOUNTING HEIGHT
GRAB BAR 36" GB01 34" A.F.F. CENTERLINE
OF BAR
Grab Bars 42" GB02 34" A.F.F. centerline of bar
ABA 1 1/2" DIA. STAINLESS STEEL
HORIZONTAL TWO WALL BAR
GB03 34" A.F.F. CENTERLINE
OF BAR
SOLID PLASTIC PEDESTAL BENCH LB
Personal Storage Locker - Single Door LPS 12" X 15" X 72" SLOPED
TOP
18"W 36"H MIRROR WITH STAINLESS
STEEL FRAME
MG BOTTOM OF GLASS 40"
AFF
SEMI-RECESSED PAPER TOWEL
DISPENSER WASTE RECEPTACLE
PTDWR 48" A.F.F.
SHOWER CURTAIN & ROD SCSCR
WALL MOUNTED SOAP DISPENSER SD TOP 46" A.F.F.
SOAP HOLDER SH TOP 40' A.F.F.
UTILITY SHELF WITH RAG HOOKS
AND BROOM HOLDERS
SMHD 66" A.F.F.
SANITARY NAPKIN DISPOSER SND SURFACE MOUNTED
TOP 30" A.F.F.
TOWEL PIN TP 66" A.F.F.
TOWEL PIN ABA TPABA 44 A.F.F.
TOWEL PIN ADA TPADA
TOILET SEAT COVER DISPENSER -
SURFACE
TSCD 48" A.F.F.
TOILET TISSUE DISPENSER - 2 ROLL,
SURFACE
TTD 20" A.F.F
FIXTURE MOUNTING HEIGHTS
MENS ROOM B108 ELEV. A1
MENS ROOM B108 ELEV. B2
MENS ROOM B108 ELEV. C3
MENS ROOM B108 ELEV. D4
MENS ROOM B108 ELEV. F5
MENS ROOM B108 ELEV. G6
BREAKROOM B107 ELEV. A7
JANITORS CLOSET B111 ELEV. A8
JANITORS CLOSET C101 ELEV. A9
JANITORS CLOSET D103 ELEV. A10
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 8
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
8' - 0"
3'
0" 4'
0"
4'
0" 4'
0"
5"3' - 4"6"3' - 4"5"
" F
R
AM
E H
EI
G
H T
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
PALLET STORAGE RACKS
FOOT PLATE SIZE TO BE A
MINIMUM OF 5" X 7" (35 SQ. INCHES)
WITH (4) 1/2 INCH DIAMETER
ANCHOR BOLTS (TYPICAL)
PALLET RACK BEAM WITH
HEAVY DUTY BEAM END
CONNECTORS
NOTE:
PROVIDE TWO HEAVY DUTY
CROSS BARS FOR EACH
PALLET
FINISHED FLOOR
3' - 6" 1' - 0"
4'
0" 4'
0"
4'
0" 3'
0"
4' - 0"
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
" F
R
AM
E H
EI
G
H T
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
4000 LBS MAX.
TOTAL WEIGHT
INCLUDES
PALLET
CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
PALLET STORAGE RACKS
FOOT PLATE SIZE TO BE A
MINIMUM OF 5" X 7" (35 SQ. INCHES)
WITH (4) 1/2 INCH DIAMETER
ANCHOR BOLTS (TYPICAL)
PROVIDE RIGID ROW AND
RIGID WALL SPACERS
"NOTE:
PROVIDE TWO HEAVY DUTY
CROSS BARS FOR EACH
PALLET
FINISHED FLOOR
EQUAL EQUAL
2' - 0 3/4"
4"
1' - 4 3/4"
4"
3'
6" 9'
4"
1'
9"
1'- 4"1'- 4"
2' - 2" 2' - 2"
3" X 1/2" THICK STEEL FLAT
SOLID BAR STOCK SIDE RAILS
4" X 7 3/4" X 1/2" THICK STEEL
BENT PLATE LADDER SUPPORT
WITH 5/8" DIAMETER EXPANSION
BOLTS. SUPPORTS SPACED AT
48" O.C. VERTICALLY
LADDER RUNGS- 3/4" DIAMETER
ROUND BARS AT 12" O.C. VERTICALLY
MAXIMUM (TYPICAL)
4" X 4" X 1/2" THICK STEEL ANGLE
WITH 5/8" DIAMETER EXPANSION BOLT
FINISHED FLOOR
C O
N
TR
AC
TO
R T
O V
ER
IF
Y H
EI
G
H T
AT
R
O O
F H
AT
C
H P
R
IO
R T
O F
AB
R
IC
AT
IO
N
R = 1"
FRONT VIEW TOP VIEW
SIDE VIEW
2" 3"
3" 2"
2" 2"
4' -0
" A .F
.F
3/8" DIAMETER
STAINLESS STEEL
ROD
3/8" DIAMETER
STAINLESS STEEL
ROD
3/8" DIAMETER
STAINLESS STEEL
ROD
3/8" DIAMETER
STAINLESS STEEL
ROD
INTERIOR
FACE OF VAULT
WALL
LINE OF VAULT
WALL
LINE OF VAULT
WALL
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt
6/27/2018 4:24:25 PM
AP
R
IL
W
2H N
-1 8-
B-
P.
S
U
LL
IV
AN
Au th or
T.
D
C
AT
C
O D
E
A-522
IN
TE
R
IO
R D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
C he ck er
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 9
TYPICAL PALLET STORAGE FRONT ELEVATION1
TYPICAL PALLET STORAGE SIDE ELEVATION2
1 2 42
SCALE: 1/2"=1'-0"
1 2 42
SCALE: 1/2"=1'-0"
LADDER 2 ,3 AND GUARDRAIL ELEVATIONS3
FACE OF WALL
FINISHED
FLOOR
1 1/2" DIAMETER GUARDRAIL
(TYPICAL)
3" X 6" X 1/2" STEEL
WALL CONNECTION
PLATE WITH (2) 3/8"
DIAMETER EXPANSION
BOLTS (TYPICAL)
4" X 4" X 3/8" STEEL ANGLE
TOE BOARD WITH 3/8" DIAMETER
EXPANSION BOLTS AT 16" O.C.
3" X 1/2" THICK STEEL FLAT
SOLID BAR STOCK SIDE RAILS
4" X 7 3/4" X 1/2" THICK STEEL
BENT PLATE LADDER SUPPORT
WITH 5/8" DIAMETER EXPANSION
BOLTS. SUPPORTS SPACED AT
48" O.C. VERTICALLY
LADDER RUNGS- 3/4" DIAMETER
ROUND BARS AT 12" O.C. VERTICALLY
MAXIMUM (TYPICAL)
LADDER EXTENSION GUARDRAIL RAIL RETURNS WELDED TO
LADDER EXTENSIONS (TYPICAL)
4" X 4" X 1/2" THICK STEEL ANGLE
WITH 5/8" DIAMETER EXPANSION BOLT
1 2 42
SCALE: 1/2"=1'-0"
01 2 42
SCALE: 1/2"=1'-0"
SBP- STRUCTURAL BARRIER POST
LADDER 1- LADDER TO ROOF4
1 2 42
SCALE: 1/2"=1'-0"
ARMS ROOM ANCHOR DETAIL5
6"6"
SCALE: 3"=1'-0"
04 2
A.
F.
F.
2'
8" 5'
4"
6' - 0"
A
A-609
A-609
A-609
A-609
A-801
10' - 0"
A.
F.
F.
2'
8" 5'
4"
B
A-609
A-609
A-609
5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"
2'
3/
4" 4'
1/ 2"
2'
/4
C
A-609A
A-609A
A-609A
A-803
5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"
2'
3/
4" 4'
1/ 2"
2'
/4
D
A-609A
A-609A
A-609A
3' - 9" 3' - 9"
2'
/4
4'
1/
2" 2'
3/ 4"
E
A-609
A-609A
A-609
" A
.F .F
/4
4'
0" 3'
1/ 4"
4'
1/
2"
7' - 6"
3' - 9" 3' - 9"
F
A-609
A-609
A-609
5' - 2 3/4" 6' - 2 1/2" 5' - 2 3/4"
" A
.F .F
4'
0"
3'
1/
4" 4'
3/ 4"
16' - 8"
G
A-609
A-609
A-609
A-801
TOS 2
23' - 6"
15' - 0"
" A
.F .F
A-609A
A-609A
A-609A
A-801
20' - 0"
A-609A
A-609A
A-609A
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt
6/27/2018 4:24:48 PM
AP
R
IL
W
2H N
-1 8-
B-
P.
S
U
LL
IV
AN
Au th or
T.
D
C
AT
C
O D
E
A-608
W
IN
D O
W T
YP
ES
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
XX
X
YY
Y
ISSUED FOR CONSTRUCTION
H I
WINDOW TYPES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
FIRE ALARM AND MASS NOTIFICATION SYMBOLS
FIRE ALARM MANUAL PULL STATION.
FACP
MNS
LOC
F
DH
RA
RM
S
CO
DOOR HOLDER WALL MAGNET. RELEASES DOOR UPON FIRE ALARM SYSTEM
ACTIVATION OR LOSS OF BUILDING NORMAL POWER.
FIRE ALARM STROBE (CLEAR), WALL MOUNTED. WHERE PRESENT, NUMBER
INDICATES INTENSITY. WHERE NOT PRESENT, INTENSITY SHALL BE 30 CANDELA
(CD). "WP" INDICATES WEATHERPROOF.
MASS NOTIFICATION SYSTEM STROBE (AMBER), WALL MOUNTED. WHERE PRESENT,
NUMBER INDICATES INTENSITY. WHERE NOT PRESENT, INTENSITY SHALL BE 30
CANDELA (CD). "WP" INDICATES WEATHERPROOF.
MASS NOTIFICATION/ PAGING SYSTEM SPEAKER, CEILING MOUNTED.
MASS NOTIFICATION/ PAGING SYSTEM SPEAKER, WALL MOUNTED.
'WP' INDICATES WEATHERPROOF.
HEAT DETECTOR
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
DUCT SMOKE DETECTOR
SPRINKLER SYSTEM FLOW SWITCH
SPRINKLER SYSTEM TAMPER SWITCH
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
MASS NOTIFICATION SYSTEM CONTROL PANEL
FLUSH-MOUNTED MASS NOTIFICATION SYSTEM LOCAL OPERATOR CONSOLE
FIRE ALARM ADDRESSABLE RELAY MODULE
FIRE ALARM ANNUNCIATOR HORN. "WP" INDICATES WEATHERPROOF.
MASS NOTIFICATION TRANSMITTER ANTENNA
A AMPERE
AFF ABOVE FINISHED FLOOR
C CONDUIT
COR CONTRACTING OFFICER'S REPRESENTATIVE
CU COPPER
FACP FIRE ALARM CONTROL PANEL
GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED
FADS FIRE ALARM AND DETECTION SYSTEM
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
LED LIGHT EMITTING DIODE
MFR MANUFACTURER
MH MOUNTING HEIGHT
MNS MASS NOTIFICATION SYSTEM
NEC NATIONAL ELECTRICAL CODE
NO. NUMBER
PAF PAINTED AFTER FABRICATION
PIR PASSIVE INFRARED
R/W RACEWAY
SPD SURGE PROTECTIVE DEVICE
TR TRANSFORMER
TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR
TYP TYPICAL
UL UNDERWRITERS LABORATORY
UOI UNLESS OTHERWISE INDICATED
UON UNLESS OTHERWISE NOTED
V VOLT
W, WP WEATHERPROOF
1. CONDUITS SHALL BE CONCEALED IN CEILINGS AND
WALLS, EXCEPT AS SHOWN OTHERWISE.
2. MOUNT OUTLET BOXES SO THAT NONE OCCUR
BACK TO BACK IN WALLS.
3. SEAL PENETRATIONS THROUGH FLOORS OR FIRE
WALLS TO MAINTAIN THE INTEGRITY OF THE FIRE
AND ACOUSTIC RATINGS OF THE WALLS AND FLOORS.
4. RACEWAYS CROSSING STRUCTURAL EXPANSION
JOINTS OR SEISMIC JOINTS SHALL BE PROVIDED
WITH SUITABLE EXPANSION FITTINGS OR OTHER
SUITABLE MEANS TO COMPENSATE FOR THE BUILDING
EXPANSION AND CONTRACTION AND TO PROVIDE
FOR CONTINUITY OF GROUNDING.
5. FOR TYPICAL MOUNTING HEIGHTS, SEE E-001.
GENERAL NOTES ABBREVIATIONS
FIRE ALARM/MASS NOTIFICATION
SYSTEMS OPERATIONS MATRIX
NOTES, FIRE ALARM & MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATION:
1A. SUBSEQUENT ACTUATION OF OTHER INITIATING DEVICES OR SUPERVISORY SIGNALS AFTER THE INITIAL ALARM OR SUPERVISORY SIGNAL HAS BEEN SILENCED SHALL CAUSE
THE NOTIFICATION APPLIANCES TO REACTIVATE.
1B. IF AN AUDIBLE TROUBLE SIGNAL HAS BEEN SILENCED, IT SHALL COMPLY WITH THE FOLLOWING:
i. THE AUDIBLE TROUBLE SHALL RE-SOUND EVERY 24 HOURS OR LESS UNTIL FAULT CONDITIONS ARE RESTORED TO NORMAL.
ii. THE RE-SOUNDED AUDIBLE TROUBLE SIGNAL SHALL SOUND UNTIL IT IS MANUALLY SILENCED OR ACKNOWLEDGED.
iii. THE RE-SOUNDED AUDIBLE TROUBLE SIGNAL SHALL ALSO BE AUTOMATICALLY RETRANSMITTED TO THE BASE FIRE DEPARTMENT.
1C. WHEN THE SILENCE SWITCH IS LEFT IN THE "OFF" POSITION AND THERE IS NO ALARM, SUPERVISORY, OR TROUBLE SIGNAL, AN AUDIBLE TROUBLE SIGNAL AND A VISUAL INDICATOR SHALL BE ACTIVATED UNTIL THE SWITCH IS RESTORED TO ITS NORMAL POSITION.
2. THE MASS NOTIFICATION SYSTEM SHALL TEMPORARILY INTERRUPT THE FIRE ALARM AUDIBLE MESSAGE AND VISUAL NOTIFICATION APPLIANCES DURING SIMULTANEOUS FIRE AND MASS EVACUATION EVENTS. ALL OTHER FEATURES OF THE FIRE ALARM SYSTEM SHALL FUNCTION PROPERLY. DURING THE INTERRUPTION OF THE FIRE ALARM AUDIBLE AND VISUAL SIGNALS, A DISTINCT SUPERVISORY SIGNAL SHALL BE ANNUNCIATED (BOTH AUDIBLY AND VISUALLY) AT THE FACP (AND REMOTE FIRE ALARM ANNUNCIATORS) AND SHALL
BE TRANSMITTED TO THE CENTRAL FIRE ALARM SYSTEM.
3. DUCT DETECTORS IN ALARM MODE SHALL CAUSE THE AIR HANDLER UNIT PROTECTED BY THE DETECTOR TO SHUT DOWN AND SHALL CAUSE THE ASSOCIATED SMOKE DAMPERS TO CLOSE. OTHER AIR HANDLERS PROTECTED BY NON-ALARMED DUCT DETECTORS SHALL REMAIN IN OPERATION. FOR DUCT SMOKE DETECTORS NOT READILY ACCESSIBLE
AND/OR MOUNTED GREATER THAN 6'-0" AFF, PROVIDE A REMOTE TEST SWITCH.
4. SEE FA101 AND FA102 FOR LOCATION OF DOORS TO BE UNLOCKED UPON FIRE ALARM ACTIVATION.
D
IS
PL
AY
M
ES
SA
C E
O N
F
AC
P
D
IS
PL
AY
M
ES
SA
G
E O
N F
IR
E
AL
AR
M A
N N
U N
C
IA
TO
R
R
EC
O R
D E
VE
N
T
IN
T H
E H
IS
TO
R Y
LO
G
TR
AN
SM
IT
A
LA
R M
T O
C
EN
TR
AL
F
IR
E
AL
AR
M
S
YS
TE
M
SM
IT
S U
PE
R
VI
SO
R Y
SI
G
N
AL
T O
C
EN
TR
AL
F
IR
E
AL
AR
M
S
YS
SM
IT
T R
O U
BL
E
SI
G
N
AL
T O
C
EN
TR
AL
F
IR
E
AL
AR
M
S
YS
AC
TI
VA
TE
C
LE
AR
F
IR
E
AL
AR
M N
O
TI
FI
C
AT
IO
N S
TR
O
BE
S
AC
TI
VA
TE
A M
BE
R
M
AS
S N
O
TI
FI
C
AT
IO
N S
TR
O
BE
S
BR
O
AD
C
AS
T
FI
R
E
AL
AR
M
M
ES
SA
G
E
BR
O
AD
C
AS
T
FI
R
E
AL
AR
M
T R
O U
BL
E
SI
G
N
AL
BR
AD
C
AS
T
R
EC
O R
D
ED
O R
L
IV
E M
AS
S
N O
TI
FI
C
AT
IO
N
M
ES
SA
G
E
SH
U
T D
O W
N P
R O
TE
C
TE
D
A
IR
-H
AN
D
LI
N G
U N
IT
(S
N
O
TE
U N
LO
C
K
IN
D
IC
AT
ED
D O
O R
S
VI
A D
O O
R C
O N
TR
O
LL
ER
S (N
O
TE
MANUAL FIRE ALARM PULL STATION
SPRINKLER WATER FLOW SWITCH - OTHER
SPRINKLER VALVE TAMPER SWITCH AND PIV
SMOKE DETECTOR - ESS ROOM
DUCT SMOKE DETECTOR
FACP TROUBLE
FACP SILENCE SWITCH (NOTES 1A, 1B, AND 1C)
MNS ACTIVATION (NOTE 2)
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/22/2018 4:02:44 PM
AP
R
IL
W
2H N
-1 8-
B-
- C
AT
C O
D E
FA001
FI
R
E
AL
AR
M
L
EG
EN
D
A N
D O
PE
R
AT
IO
N S
M
AT
R
IX
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
F
F
F F 245'
FA
C
P/ M
N S
RA
VESTIBULE
B100
LOBBY
B101
ELECT. ROOM
B102
T.E.R.
B103
DUTY STATION
B104
CORRIDOR
A110
MECHANICAL
A111
OPEN OFFICE
A109
CLASSROOM
A108
CO. CDR OFFICE
A102
HR OFFICE
A104
SUPPLY SGT OFFICE
A103
FIRST SGT OFFICE
A100
FILES/PRINTING
A105
SUPPLY STORAGE
A106
CORRIDOR
A110
CORRIDOR
A107
CPB READINESS AREA
C100
NERD SERVER ROOM
C102
UNIT STORAGE AREA
C103
COMM. STORAGE AREA
C104
NBC STORAGE AREA
C105
ARMS VAULT
C106
ARMS VAULT
D105
ARMY CYBER STORAGE- OUT
D104
JANITORS CLOSET
D103
ELECTRIC ROOM
D101
ESS ROOM
D102
MDP
LDP
S
LO
C
LOC
LOC
LO
C
FAS
CO
15 15
15 15
45 45
60 60
45 45
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/25/2018 4:18:09 PM
AP
R
IL
W
2H N
-1 8-
B-
- C
AT
C O
D E
FA101
FI
R
E
AL
AR
M
M
AS
S
N O
TI
FI
C
AT
IO
N
S
YS
TE
M
S
PL
AN
PA
R
TS
A
C
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
KEYED NOTES:
1. UNLOCK DOOR UPON FIRE ALARM ACTIVATION.
SEE FIRE ALARM AND MASS NOTIFICATION SYSTEM
MATRIX FOR CONDITIONS THAT SHALL UNLOCK
DOORS.
SHEET NOTES:
1. SEE SHEET FA001 FOR LEGEND, LABELING
SCHEME AND GENERAL NOTES.
KEY
PLAN
PART A PART B
PART
C
PART D
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
REF.
F
F
F F
LTB
FA
C
P/ M
N S
RA
CORRIDOR
B112
BREAKROOM
B107
RECYCLED MATERIALS
STORAGE CLOSET
B109
JANITORS CLOSET
B111
MEN LATRINE/LOCKERS
B108
WOMENS LATRINE/LOCKERS
B105
SIPR KIOSK
B113 T.R.
B116
J.F.H.Q. OFFICE 2
B115
J.F.H.Q. OFFICE 1
B114
ARMS VAULT
D105
ARMY CYBER READINESS
STORAGE - IN
D106
COMM. STORAGE AREA
D107
NBC STORAGE AREA
D108
UNIT STORAGE AREA
D109
SECURE NON SENSITIVE
STORAGE
D110
CLASSROOM
D112
CORRIDOR
B112
CORRIDOR
B126
CLASSROOM STORAGE
ROOM
B121
FILES/PRINTING
B125
OP. OFFICE
B124
XO OFFICE
B120
FIRST SGT OFFICE
B119
CDR. OFFICE
B123
CLASSROOM
B118
OPEN OFFICE
B117
S
LO
C
LOC
LO
C
15 15
6060606060
60 60
MNS
ANTENNA
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/25/2018 12:12:27 PM
AP
R
IL
W
2H N
-1 8-
B-
D es ig ne r
Au th or
Ap pr ov er
C
AT
C O
D E
FA102
FI
R
E
AL
AR
M
M
AS
S
N O
TI
FI
C
AT
IO
N
S
YS
TE
M
S
PL
AN
PA
R
TS
B
D
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
C he ck er
ISSUED FOR CONSTRUCTION
KEYED NOTES:
1. UNLOCK DOOR UPON FIRE ALARM ACTIVATION.
SEE FIRE ALARM AND MASS NOTIFICATION SYSTEM
MATRIX FOR CONDITIONS THAT SHALL UNLOCK
DOORS.
SHEET NOTES:
1. SEE SHEET FA001 FOR LEGEND, LABELING
SCHEME AND GENERAL NOTES.
KEY
PLAN
PART A PART B
PART
C
PART D
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
1 1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
ELECTRICAL LEGEND
C
R T
J
B
TTB
CTB
V
20 AMP QUAD RECEPTACLE, MH 1'-6", UON OR UOI. SUBSCRIPT 'X'
(WHERE PRESENT) DENOTES THE FOLLOWING:
OS - CONTROLLED BY ROOM OCCUPANCY SENSORS VIA
RECEPTACLE-RATED SWITCHPACK. TOP OUTLET OF EACH
RECEPTACLE STRAP SHALL BE CONTROLLED; BOTTOM
OUTLET TO BE UNCONTROLLED. OUTLET SHALL BE MARKED IN
ACCORDANCE WITH N.E.C., ARTICLE 406.3(E).
20 AMP CEILING MOUNTED RECEPTACLE OUTLET
VGA CEILING OUTLET FOR CONNECTING THE USER'S
PROJECTOR
RECESSED COMBINATION FLOOR DUPLEX RECEPTACLE
(20 AMP) AND DUPLEX TELEPHONE OUTLET
JUNCTION BOX, WALL MTD. MH 1'-6" U.O.N.
MOTOR RATED SWITCH
MOTOR DISCONNECT/SAFETY SWITCH SHALL BE RATED
30/3/NF/1 UNLESS OTHERWISE INDICATED.
'30' DENOTES SWITCH AMPERE RATING;
'3' DENOTES NUMBER OF POLES;
'NF' DENOTES NON-FUSED ('F' DENOTES FUSED);
'1' DENOTES SWITCH ENCLOSURE'S RATING;
FUSE RATING SHALL BE IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
MOTOR STARTER, FURNISHED BY OTHER SECTIONS
BOILER EMERGENCY SHUT-OFF
FIRE-RETARDANT PLYWOOD BACKBOARD WITH NO ADDED
UREA FORMALDEHYDE. SEE SPECIFICATIONS 01 33 29
FOR FSC CERTIFICATION REQUIREMENTS.
TW T #
SPD
SYSTEM GROUND, SIZE IN ACCORDANCE WITH NEC ARTICLE 250
GROUND ROD, "TW" INDICATES TEST WELL
LIGHTNING PROTECTION ROOF CONDUCTORS. SEE DRAWINGS FOR
SIZE.
AIR TERMINAL
PANELBOARD - MH IN ACCORDANCE WITH NEC
DRY-TYPE TRANSFORMER
SURGE PROTECTIVE DEVICE
LIGHTNING PROTECTION COUNTERPOISE CONDUCTORS. SEE
DRAWINGS FOR SIZE.
LED LUMINAIRES. SEE LIGHT FIXTURE SCHEDULE, DETAILS, AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
LED LUMINAIRES WITH EMERGENCY DRIVERS OR CONNECTED TO AN
EMERGENCY LIGHTING INVERTER
WALL MOUNTED LED LUMINAIRE.
WALL MOUNTED LED LUMINAIRE WITH EMERGENCY DRIVER.
WALL MOUNTED LED LUMINAIRES.
SUSPENDED LED LUMINAIRE.
SUSPENDED LED LUMINAIRE WITH INTEGRAL EMERGENCY
DRIVER.
EXIT LIGHT, CEILING MOUNTED, SHADING INDICATES FACES.
PROVIDE DIRECTIONAL ARROWS WHEN INDICATED.
EXIT LIGHT, WALL MOUNTED, SHADING INDICATES FACES. PROVIDE
DIRECTIONAL ARROWS WHEN INDICATED. MOUNT BOTTOM OF
FIXTURE 6" ABOVE TOP OF DOOR UNLESS OTHERWISE INDICATED.
WALL SWITCH, SINGLE POLE, 20A SWITCH. WHERE SUBSCRIPT IS PRESENT,
IT DENOTES THE FOLLOWING:
3 - THREE WAY SWITCH.
4 - FOUR WAY SWITCH.
a - SINGLE LOWER CASE LETTER (EXCEPT LETTER "m") DENOTE THE
SWITCH THAT CONTROLS THE FIXTURES.
WP - WEATHERPROOF (GASKETED).
MOTOR RATED SWITCH FOR CEILING FAN.
WALL SWITCH SENSOR, LINE VOLTAGE. SUBSCRIPTS ARE DENOTED VIA
DETAILS ON SHEET EL601.
DIGITAL TIME SWITCH, LINE VOLTAGE. SEE DETAIL ON SHEET EL601.
LOW VOLTAGE, MULTI-BUTTON SWITCH CONNECTED TO ROOM CONTROLLER
OR LIGHTING CONTROL PANEL. SUBSCRIPTS ARE DENOTED VIA DETAILS ON
SHEET EL601.
OCCUPANCY SENSOR. WALL MOUNTED, DUAL TECHNOLOGY (ULTRASONIC
AND PIR) SENSOR UOI. SUBSCRIPT "P" INDICATES ONLY PIR.
OCCUPANCY SENSOR. CEILING MOUNTED, ULTRASONIC SENSOR UOI.
DAYLIGHT SENSOR.
EXTERIOR PHOTOCELL.
LIGHTING CONTROL PANEL (LCP).
EMERGENCY LIGHTING INVERTER.
LOWER CASE DENOTES THE SWITCH THAT CONTROLS FIXTURE
LUMINAIRE TYPE DESIGNATION
SYMBOL DENOTES GENERAL TYPE OF LUMINAIRE
UNSWITCHED NIGHT LIGHT (ON 24
HOURS)
a A2
NT
T
LCP
OS
DS
LVX
ELI
PC
LIGHTING AND LIGHTING CONTROLS SYSTEM LEGEND
OSX
fan
20 AMP QUAD RECEPTACLE, MOUNTED IN FLOOR BOX.
GENERAL NOTES
1. SEE PLATE E-002 FOR ABBREVIATIONS AND TYPICAL MOUNTING HEIGHT
DIAGRAM.
2. MOUNTING HEIGHT, UNLESS OTHERWISE NOTED, IS TO CENTER LINE OF
EQUIPMENT.
3. MOUNT OUTLET BOXES SO THAT NONE OCCUR BACK TO BACK IN WALLS.
4. MECHANICAL EQUIPMENT IS SHOWN IN APPROXIMATE LOCATIONS. FOR
EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND PIPING, SEE MECHANICAL
DRAWINGS. PROVIDE DISCONNECT SWITCHES AS REQUIRED BY THE NATIONAL
ELECTRICAL CODE EVEN IF NOT INDICATED ON THE ELECTRICAL DRAWINGS.
5. COORDINATE THE LOCATIONS AND MOUNTING HEIGHTS OF LIGHTING
FIXTURES IN MECHANICAL AND ELECTRICAL ROOMS WITH THE FINAL LOCATIONS
OF PIPES, DUCTS AND OTHER EQUIPMENT FOR BEST ARRANGEMENT. FIXTURES
SHALL BE EASILY ACCESSIBLE FOR RELAMPING.
6. CONDUCTOR AND CONDUIT SIZES ARE BASED ON COPPER CONDUCTORS
WITH THWN INSULATION IN EMT CONDUIT. CIRCUIT BREAKERS, TERMINALS, ETC.
SHALL BE RATED AND MARKED FOR 75 DEGREES MINIMUM. THE CONTRACTOR
SHALL ADJUST CONDUIT SIZES BASED ON ACTUAL TYPE OF CONDUCTORS AND
CONDUIT INSTALLED.
7. CIRCUIT NUMBERS ARE SHOWN ADJACENT TO ELECTRICAL DEVICES. WIRING
SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS
AND/OR REQUIREMENTS.
8. ALL WIRING SHALL BE CONCEALED UNLESS INDICATED OTHERWISE.
CONDUITS SHALL NOT BE RUN IN ANY UL RATED SLAB.
9. REVISE PANELBOARD SCHEDULES ON AS-BUILT-DRAWING AND PANEL
DIRECTORIES TO REFLECT FINAL INSTALLATION CONDITIONS.
10. SEAL PENETRATIONS THROUGH ROOFS, CEILINGS, FLOORS, WALLS AND
FIRE WALLS TO MAINTAIN THE INTEGRITY OF THE AIR BARRIER, FIRE AND
ACOUSTIC RATINGS OF THE ROOF, CEILINGS, WALLS AND FLOORS.
11. COMPONENTS WHICH CONSTITUTE AN ELECTRICAL SYSTEM SHALL BE FULLY
COMPATIBLE WITH ONE ANOTHER AND SHALL BE APPROVED BY THE VARIOUS
MANUFACTURERS FOR USE WITH ALL OTHER COMPONENTS WITHIN THE
SYSTEM. (ONE EXAMPLE OF AN ELECTRICAL SYSTEM IS THE BUILDING LIGHTING
SYSTEM COMPRISED OF FIXTURES, LAMPS, SWITCHES, BALLASTS, OCCUPANCY
SENSORS AND DIMMING EQUIPMENT).
12. LOCATE ALL RACEWAYS TO AVOID INTERFERENCE WITH DUCTS, PIPES,
MECHANICAL EQUIPMENT, WITH REMOVAL OF CEILING TILES, OR WITH ACCESS
TO EQUIPMENT WHICH REQUIRES PERIODIC ADJUSTMENT OR MAINTENANCE.
13. PROVIDE NAMEPLATES ON THE EXTERIOR OF ALL ELECTRICAL PANELS AND
ENCLOSURES AS FOLLOWS: DEVICE ID, DEVICE RATING, POWER SOURCE, ARC
FAULT DATA. ARC-FAULT DATA SHALL MEET 2015 NFPA 70E REQUIREMENTS.
14. FOR DISCONNECT SWITCHES AND MOTOR STARTERS THE TOP LINE SHALL
BE THE NAME/DESIGNATION OF THE EQUIPMENT BEING FED BY THE
SWITCH/STARTER.
15. PROVIDE SEPARATE NEUTRALS FOR EACH CIRCUIT UTILIZING A NEUTRAL
CONDUCTOR. MULTI-WIRE CIRCUITS ARE NOT ALLOWED.
16. PROVIDE EQUIVALENT CONDUIT PATHWAYS WHERE CABLE TRAY IS
INTERRUPTED BY NONACCESSIBLE CEILINGS.
17. THE INTERRUPTING RATING OF THE PANELBOARDS AND ELECTRICAL
EQUIPMENT SHALL BE INCREASED TO THE NEXT AVAILABLE RATING WHERE
THERE IS NOT A RATING THAT IS EQUAL TO THE EQUIPMENT'S LISTED SHORT
CIRCUIT RATING.
18. PROVIDE GROUNDING CONDUCTORS IN ALL CONDUITS.
19. RACEWAYS CROSSING STRUCTURAL EXPANSION JOINTS OR SEISMIC JOINTS
SHALL BE PROVIDED WITH EXPANSION FITTINGS TO COMPENSATE FOR THE
BUILDING EXPANSION AND CONTRACTION AND TO PROVIDE FOR CONTINUITY OF
GROUNDING. EXPANSION FITTINGS SHALL HAVE AN INTEGRAL BONDING
JUMPER. ONLY FITTING LISTED AS EXPANSION TYPES WILL BE CONSIDERED
SUITABLE.
20. RECEPTACLES THAT HAVE GFI PROTECTION ARE TO BE WIRED SUCH THAT
THE LOSS OF POWER ON ONE RECEPTACLE DOES NOT AFFECT DOWNSTREAM
RECEPTACLES.
20 AMP DUPLEX RECEPTACLE, SUBSCRIPT 'X' (WHERE PRESENT)
DENOTES THE FOLLOWING:
WP - DENOTES WEATHER PROOF WHILE-IN-USE HOUSING.
GFCI - DENOTES GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
RECEPTACLE
GC - DENOTES ABOVE COUNTERTOP GFCI RECEPTACLE.
EWC - DENOTES ELECTRIC WATER COOLER.
COORDINATE MOUNTING WITH EQUIPMENT PROVIDED.
TV - DENOTES TELEVISION. COORDINATE MOUNTING WITH CATV
OUTLET.
OS - CONTROLLED BY ROOM OCCUPANCY SENSORS VIA
RECEPTACLE-RATED SWITCHPACK. TOP OUTLET OF EACH
DUPLEX RECEPTACLE SHALL BE CONTROLLED; BOTTOM
OUTLET TO BE UNCONTROLLED. OUTLET SHALL BE MARKED IN
ACCORDANCE WITH N.E.C., ARTICLE 406.3(E).
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXMPB\Documents\FY17PN85794_MEP_R18_K6ENXMPB.rvt
6/28/2018 12:00:55 PM
AP
R
IL
W
2H N
-1 8-
B-
SJ
A
C
AT
C O
D E
E-001
EL
EC
TR
IC
AL
L
EG
EN
D
G
EN
ER
AL
N O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
J
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/25/2018 4:40:40 PM
AP
R
IL
W
2H N
-1 8-
B-
SJ
A
C
AT
C O
D E
EG101
LI
G
H
TN
IN
G
P R
O
TE
C
TI
O N
P
LA
N
PA
R
TS
A
C
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
KEYED NOTES:
1. CLASS 1 MAIN CONDUCTOR SIZED 57,400
CIRCULAR MILS.
SHEET NOTES:
1. SEE SHEET E-001 FOR LEGEND, AND GENERAL
NOTES.
2. THE LIGHTNING PROTECTION INSTALLER SHALL
COORDINATE ROOF PENETRATIONS WITH THE ROOF
INSTALLER. PENETRATIONS SHALL COMPLY WITH
THE ROOF MANUFACTURER'S RECOMMENDATIONS.
SEALING AND FLASHING OF PENETRATIONS SHALL
BE BY THE ROOF INSTALLER.
3. VARIATIONS IN AIR TERMINAL SPACING SHALL BE
ALLOWED WHERE REQUIRED TO ACCOMMODATE
SITE CONDITIONS, EXCEPT NO SPACING BETWEEN
AIR TERMINALS SHALL EXCEED 20 FEET AND NO
PERIMETER AIR TERMINALS SHALL BE MORE THAN
24 INCHES FROM ROOF EDGE.
4. ROOF MOUNTED MECHANICAL VENT PIPING AND
EQUIPMENT SHALL BE PROTECTED WITH AIR
TERMINALS INTERCONNECTED WITH THE LIGHTNING
PROTECTION SYSTEM PER THE DETAIL ON EG501.
SEE MECHANICAL DRAWINGS FOR LOCATIONS OF
MECHANICAL VENT PIPING AND EQUIPMENT.
5. SEE STRUCTURAL DRAWINGS FOR EXACT
LOCATIONS OF COLUMNS.
6. METAL PARTS WITHIN 6 FEET OF THE LIGHTNING
PROTECTION SYSTEM SHALL BE BONDED TO THE
LIGHTNING PROTECTION SYSTEM. METAL PARTS
FURTHER THAN 6 FEET SHALL ALSO BE BONDED IF
THEY ARE WITHIN 6 FEET OF A METAL PART THAT IS
BONDED TO THE LIGHTNING PROTECTION SYSTEM.
7. LIGHTNING PROTECTION CONDUCTORS PASSING
THROUGH CONCRETE FOUNDATION, SLABS OR PADS
SHALL BE ROUTED IN CONDUIT.
8. TEE SPLICES SHALL BE EXOTHERMIC WELDED
BELOW GRADE.
9. INSTALLED LIGHTNING PROTECTION SYSTEM
SHALL BE FIELD INSPECTED BY CONTRACTOR-
PROVIDED INDEPENDENT TESTING AGENCY AND
FURNISHED WITH A UL MASTER LABEL FOR
LIGHTNING PROTECTION SYSTEM.
10. ADDITIONAL REQUIREMENTS ARE LOCATED IN
SPEC 26 41 01.00 10, LIGHTNING PROTECTION
SYSTEM.
11. MAIN CONDUCTORS SHALL BE CLASS 1
MATERIALS IAW NFPA 780.
KEY
PLAN
PART A PART B
PART
C
PART D
SCALE: 3/32"=1'-0"
816 16
GRAPHIC SCALE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 8
TYP.
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/25/2018 4:40:49 PM
AP
R
IL
W
2H N
-1 8-
B-
SJ
A
C
AT
C O
D E
EG102
LI
G
H
TN
IN
G
P R
O
TE
C
TI
O N
P
LA
N
PA
R
TS
B
D
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
KEYED NOTES:
1. CLASS 1 MAIN CONDUCTOR SIZED 57,400
CIRCULAR MILS.
SHEET NOTES:
1. SEE SHEET E-001 FOR LEGEND, AND GENERAL
NOTES.
2. THE LIGHTNING PROTECTION INSTALLER SHALL
COORDINATE ROOF PENETRATIONS WITH THE ROOF
INSTALLER. PENETRATIONS SHALL COMPLY WITH
THE ROOF MANUFACTURER'S RECOMMENDATIONS.
SEALING AND FLASHING OF PENETRATIONS SHALL
BE BY THE ROOF INSTALLER.
3. VARIATIONS IN AIR TERMINAL SPACING SHALL BE
ALLOWED WHERE REQUIRED TO ACCOMMODATE
SITE CONDITIONS, EXCEPT NO SPACING BETWEEN
AIR TERMINALS SHALL EXCEED 20 FEET AND NO
PERIMETER AIR TERMINALS SHALL BE MORE THAN
24 INCHES FROM ROOF EDGE.
4. ROOF MOUNTED MECHANICAL VENT PIPING AND
EQUIPMENT SHALL BE PROTECTED WITH AIR
TERMINALS INTERCONNECTED WITH THE LIGHTNING
PROTECTION SYSTEM PER THE DETAIL ON EG501.
SEE MECHANICAL DRAWINGS FOR LOCATIONS OF
MECHANICAL VENT PIPING AND EQUIPMENT.
5. SEE STRUCTURAL DRAWINGS FOR EXACT
LOCATIONS OF COLUMNS.
6. METAL PARTS WITHIN 6 FEET OF THE LIGHTNING
PROTECTION SYSTEM SHALL BE BONDED TO THE
LIGHTNING PROTECTION SYSTEM. METAL PARTS
FURTHER THAN 6 FEET SHALL ALSO BE BONDED IF
THEY ARE WITHIN 6 FEET OF A METAL PART THAT IS
BONDED TO THE LIGHTNING PROTECTION SYSTEM.
7. LIGHTNING PROTECTION CONDUCTORS PASSING
THROUGH CONCRETE FOUNDATION, SLABS OR PADS
SHALL BE ROUTED IN CONDUIT.
8. TEE SPLICES SHALL BE EXOTHERMIC WELDED
BELOW GRADE.
9. INSTALLED LIGHTNING PROTECTION SYSTEM
SHALL BE FIELD INSPECTED BY CONTRACTOR-
PROVIDED INDEPENDENT TESTING AGENCY AND
FURNISHED WITH A UL MASTER LABEL FOR
LIGHTNING PROTECTION SYSTEM.
10. ADDITIONAL REQUIREMENTS ARE LOCATED IN
SPEC 26 41 01.00 10, LIGHTNING PROTECTION
SYSTEM.
11. MAIN CONDUCTORS SHALL BE CLASS 1
MATERIALS IAW NFPA 780.
KEY
PLAN
PART A PART B
PART
C
PART D
SCALE: 3/32"=1'-0"
816 16
GRAPHIC SCALE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 8
TYP.
SBB
PBB
PGB
PM
G
B
2 2
T.E.R.
B103
TW
TW TW
ELECT. ROOM
B102
MECHANICAL
A111
OH
ELECTRIC
ROOM
D101
NERD
SERVER
ROOM
C102
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/25/2018 4:10:04 PM
AP
R
IL
W
2H N
-1 8-
B-
SJ
A
C
AT
C O
D E
EG103
G R
O U
N D
IN
G
P
LA
N
PA
R
TS
A
C
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
KEYED NOTES:
1. GROUND RING LOOP CONDUCTOR SIZED IAW
N.E.C. ARTICLE 250 AND NFPA 780.
SHEET NOTES:
1. SEE SHEET E-001 FOR LEGEND, LABELING
SCHEME AND GENERAL NOTES.
KEY
PLAN
PART A PART B
PART
C
PART D
SCALE: 3/32"=1'-0"
816 16
GRAPHIC SCALE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 8
TYP. 1
SBB
TW
TW
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/25/2018 4:10:27 PM
AP
R
IL
W
2H N
-1 8-
B-
SJ
A
C
AT
C O
D E
EG104
G R
O U
N D
IN
G
P
LA
N
PA
R
TS
B
D
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
KEYED NOTES:
SHEET NOTES:
1. SEE SHEET E-001 FOR LEGEND, LABELING
SCHEME AND GENERAL NOTES.
KEY
PLAN
PART A PART B
PART
C
PART D
SCALE: 3/32"=1'-0"
816 16
GRAPHIC SCALE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
1 8
1. GROUND RING LOOP CONDUCTOR SIZED IAW
N.E.C. ARTICLE 250 AND NFPA 780.
TYP.
PRIMARY BONDING BUSBAR (PBB)
2-HOLE COMPRESSION
CRIMP GROUNDING LUG
SECONDARY BONDING BUSBAR (SBB)
NOTES: (TELECOMMUNICATION GROUND BUS DETAILS)
1.FOR ELECTRICAL NOTES, ABBREVIATIONS, AND SYMBOLS REFER
TO DRAWING E-001.
2. TMGB BUSBARS SHALL BE A MINIMUM 1/4" THICK, 4" WIDE AND
20" LONG. TGB BUSBARS SHALL BE A MINIMUM 1/4" THICK, 2" WIDE
AND 20" LONG. BUSBARS SHALL BE INSULATED FROM THEIR
SUPPORTS BY A MINIMUM OF 2”. THE COPPER BUSBARS SHALL BE
UL LISTED AND PRE-DRILLED WITH STANDARD NEMA BOLT HOLE
SIZING AND SPACING FOR THE TYPE AND SIZE OF CONDUCTOR
BEING USED. THE BUSBARS SHALL BE CLEANED PRIOR TO
FASTENING OF CONDUCTORS AND AN ANTI-OXIDANT SHOULD BE
APPLIED TO THE CONTACT AREA TO CONTROL CORROSION AND
REDUCE CONTACT RESISTANCE. THE BUSBARS SHALL BE
MOUNTED AT 18 INCH ABOVE FINISHED FLOOR UNLESS
OTHERWISE INDICATED.
3. TELECOMMUNICATIONS BONDING CONDUCTORS SHALL BE SIZED
IN ACCORDANCE TO TIA-607-B, 6.3.2. SIZING THE
TELECOMMUNICATIONS BONDING BACKBONE (TBB), TABLE 1 AND
6.3.3. SIZING THE BONDING CONDUCTOR FOR
TELECOMMUNICATIONS (BCT) WITH A MINIMUM OF 6 AWG.
4. ALL GROUNDING CONDUCTORS ARE NOT SHOWN. SEE
TELECOMMUNICATIONS GROUNDING RISER DIAGRAM AND
SPECIFICATIONS FOR ADDITIONAL GROUNDING CONDUCTORS AND
REQUIREMENTS.
COPPER GROUNDING
BUSBAR
GROUNDING LUG
MOUNTING HOLES
STANDOFF
MOUNTING
BRACKET
INSULATOR
2-HOLE COMPRESSION
CRIMP GROUNDING LUG
COPPER GROUNDING
BUSBAR
GROUNDING LUG
MOUNTING HOLES
STANDOFF
MOUNTING
BRACKET
INSULATOR
TELECOMMUNICATION GROUND BUS DETAILS
NOT TO SCALE
COPPER GROUNDING
BUSBAR
GROUNDING LUG
MOUNTING HOLES
STANDOFF
MOUNTING
BRACKET
INSULATOR
GROUNDING
LUG
POWER MAIN GROUND BUS (PMGB)
COPPER GROUNDING
BUSBAR
GROUNDING LUG
MOUNTING HOLES
STANDOFF
MOUNTING
BRACKET
INSULATOR
GROUNDING
LUG
POWER GROUND BUS (PGB)
NOTES:
1. FOR ELECTRICAL NOTES, ABBREVIATIONS, AND SYMBOLS REFER
TO DRAWING E-001.
2. GROUNDING BUSBARS SHALL BE A MINIMUM 1/4" THICK, (2" WIDE -
TGB) AND (4" WIDE - TMGB) WITH LENGTH AS REQUIRED AND SHALL
BE INSULATED FROM ITS SUPPORTS BY A MINIMUM OF 2”. THE
COPPER BUSBARS SHALL BE A PRE-DRILLED WITH STANDARD NEMA
BOLT HOLE SIZING AND SPACING FOR THE TYPE AND SIZE OF
CONDUCTOR BEING USED. THE BUSBARS SHALL BE CLEANED PRIOR
TO FASTENING OF CONDUCTORS AND AN ANTI-OXIDANT SHOULD BE
APPLIED TO THE CONTACT AREA TO CONTROL CORROSION AND
REDUCE CONTACT RESISTANCE. THE BUSBARS SHALL BE MOUNTED
AT 18 INCH ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED.
3. POWER BONDING CONDUCTORS SHALL BE SIZED IN ACCORDANCE
N.E.C. ARTICLE 250 WITH A MINIMUM CONDUCTOR SIZE OF 6 AWG.
4. ALL GROUNDING CONDUCTORS ARE NOT SHOWN. SEE PLANS AND
SPECIFICATIONS FOR ADDITIONAL GROUNDING CONDUCTORS OR
REQUIREMENTS.
COPPER GROUNDING
BUSBAR
GROUNDING LUG
MOUNTING HOLES
STANDOFF
MOUNTING
BRACKET
INSULATOR
GROUNDING
LUG
CABLE TV SYSTEM GROUND BUS (CGB)
ELECTRICAL POWER GROUND BUS DETAILS
NOT TO SCALE
PROVIDE REINFORCED CONCRETE
GROUND INSPECTION WELL WITH CAST
IRON LID MARKED "GROUND". MOUNT
WELL FLUSH WITH FINISHED GRADE.
COPPER CLAD GROUND ROD. TOP OF
ROD SHALL BE NOT LESS THAN 18"
BELOW GRADE AND A MINIMUM OF 24"
AWAY FROM FOOTINGS OR
FOUNDATION WALLS.
#1/0 AWG GROUND CONNECTION
TO STRUCTURE
#1/0 AWG COUNTERPOISE LOOP
MECHANICAL CLAMPING
GROUND ROD TEST WELL DETAIL
NOT TO SCALE
GROUND CONNECTION TO
STRUCTURE
BARE STRANDED COPPER
CABLE
GROUND
COUNTERPOISE &
LEAD CONDUCTORS
EXOTHERMICLY
CONNECT CABLES
TO GROUND ROD
GROUND ROD
FINISHED
GRADE
GROUND ROD CONNECTION DETAIL
NOT TO SCALE
NOTES:
1. GROUNDING SHALL BE IN ACCORDANCE WITH N.E.C. ARTICLE 250. VARIATIONS TO GROUNDING
SHOWN SHALL BE APPROVED BY THE CONTRACTING OFFICER'S REPRESENTATIVE.
2. CONDUCTORS SHALL BE SIZED BASED ON THE REQUIREMENTS OF N.E.C. ARTICLE 250.
3. LIGHTNING PROTECTION SYSTEM COUNTERPOISE CONDUCTOR SIZE SHALL BE IN ACCORDANCE
WITH NFPA 780 AND UL 96.
N
GPMGB
SERVICE
ENTRANCE
EQUIPMENT
ELEC ROOM
STRUCTURAL
STEEL
FOOTING
REBAR
METALLIC
WATER PIPE
(WHERE
APPLICABLE)
LIGHTNING
PROTECTION
SYSTEM
COUNTERPOISE
NOTE 3
GROUND
ROD
ELEC ROOM
TMGB
T.E.R.
GROUNDING ELECTRODE SYSTEM DETAIL
NOT TO SCALE
KEYED NOTES:
1. #6 AWG COPPER BONDING JUMPER.
2. #4 AWG COPPER BONDING JUMPER.
3. SIZED IN ACCORDANCE WITH N.E.C.
ARTICLE 250.66.
4. SIZED SAME AS COUNTERPOISE
CONDUCTOR. CONDUCTORS SIZED IAW
NFPA 780 AND UL 96.
43121
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt
6/25/2018 5:04:21 PM
AP
R
IL
W
2H N
-1 8-
B-
- C
AT
C O
D E
EG502
M
IS
C
EL
LA
N
EO
U
S G
R O
U N
D
IN
G D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AR
C
YB
ER
C O
M
PA
N Y
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
PN
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
N
OS
OS
OS
DS
OS
DS
OS
OS OS
OS OS
A2HA2H
A2HA2H
A2HA2H
A2HA2H
A2L A2L A2LE A2L A2LE
A2LE L3
A2L
A2H A2HE A2H A2H
A2H A2H A2H A2H
A2H
A2H A2HE A2H
A2H A2H A2H A2H
A2LE A2L A2L A2LE
A2H
A2L A2L
A2LE
A2L
L3
L3
L3
L3
L3
A2L
A2L
A2HA2H
A2HA2H
A2HA2H
A2HA2HE
A2HA2H
A2L
A2LA2L
A2L
L6E
L6
L6
L6
L6
L6
L6
L6
L6
L6E
R1H R1HE
R1H R1H
A2L
A2LE
A2L
A2LE
L8L8L8F1H F1H F1H F1H F1H F1H
F1H F1HE F1H F1H F1HE F1H
F1H F1H F1H F1H F1H F1H
F1H F1H F1H F1HE F1H F1H
STORAGE CLOSET
A101
FIRST SGT OFFICE
A100
CO. CDR OFFICE
A102
CLASSROOM
A108
OPEN OFFICE
A109
MECHANICAL
A111
ELECT. ROOM
B102
SU
PP
LY
S
G T
O
FF
IC
E
A1
FI
LE
S/
PR
IN
TI
N G
A1
T.E.R.
B103
DUTY STATION
B104
SU
PP
LY
S
TO
R
AG
E
A1
NERD SERVER ROOM
C102
UNIT STORAGE AREA
C103
NBC STORAGE AREA
C105
ARMS VAULT
C106
ARMS VAULT
D105
C
PB
R
EA
D
IN
ES
S
AR
EA
C
F1L F1L
F1LE F1L
MH=10'-0" AFF (F1L)
MH=9'-0" AFF
(TYP, TYPE F1H)
S1HME
S1HM
S1HME
S1HME
S1LM S1LME S1LM
S1LME
S1LM S1LW
S1LME S1LM S1LM
F1LF1L F1LE F1L F1L
F1LF1L F1L F1L F1L
MH=9'-0" AFF
MH=9'-0" AFF
(LIGHTS AND SENSORS)
COMM. STORAGE AREA
C104
R4H
R4H
F1L
F1L
WR1
WR1E
WR1
WR1
WR1
WR1
WR1
WR1 WR1
WR1
WR1
WR1F1L
F1L
S1HM
S1HM
S1HMS1LM
S1HM S1HM S1HME S1HM S1HM
S1HM S1HM S1HM S1HME S1HM S1HM
S1LW
S1LW S1LW
S1HW S1HW S1HW S1HW
S1HW S1HW S1HW S1HW
CENTER
OVER CAGE
CENTER
OVER CAGE
CENTER
OVER CAGE
CENTER
OVER CAGE
TYPE S1L LUMINAIRES MH = 11'-0" AFF
(MEASURED TO BOTTOM OF LUMINAIRE)
S1HME
A2L F1 L
F1 L
F1 L
F1 L
A2L
MH=8'-4" AFF
MH=
8'-4" AFF
MH=9'-6" AFF
VESTIBULE
B100
LV
LV
LV
LV
LV
LV
SLVDav
OS
O S
T
CORRIDOR
A107
CORRIDOR
A110
LOBBY
B101
LV2
LV2LV2
T LV2 LV2
LV
CKT HAB- 1 CKT HAB- 1 CKT HAB- 1
CKT HAB- 1
C
KT
H
AB
-1 C
KT
H
AB
-1
C
KT
H
AB
-1CKT HAB- 2
CKT HAB- 3
CKT HAB- 2
CKT HAB- 2
CKT HAB- 8
CKT HAB- 2 CKT HAB- 4
CKT HAB- 5
CKT HAB- 3
CKT HAB- 3
CKT HAB- 3
CKT HAB- 4
C
KT
H C
D -6
C
KT
H C
D -6
C
KT
H C
D -6
CKT HCD- 7 CKT HCD- 9CKT HCD- 9 CKT HCD- 9 CKT HCD- 9
CKT HCD- 6
CKT HAB- 14
CKT HCD- 22
W2EP
W2EP
LV
LV
C
KT
H
AB
-1
W 2P
S
LVD5d
O S
12 12 12
1 1
2 5 5 1 1
4 3
W1
CKT HAB- 14
MH=1'-0" BFC
MH=9'-6" AFF
S1LM
CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3
CKT HCD- 5 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5
CKT HCD- 1 CKT HCD- 1 CKT HCD- 1 CKT HCD- 1
CKT HCD- 1 CKT HCD- 1 CKT HCD- 1 CKT HCD- 1
CKT HCD- 5
CKT HCD- 5
CKT HCD- 3 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5
CKT HCD- 3
CKT HCD- 3 CKT HCD- 1CKT HCD- 1
CKT HCD- 1CKT HCD- 1
H R
O
FF
IC
E
A1
L86R
L86
L86R
L8L8 L8 L8
L8L8…