W912HN-18-B-3001_VOL2_AMD4.pdf

PDF 5 MB Posted

Attached to
ARCYBER Company Operations Facility, Fort Gordon, GA
Solicitation number
W912HN18B3001
Issued by

About this file

Drawings Vol 2 Amd 4

View the file

Other files

File Type Posted
B.01.02_Bid_Abstract_W912HN18B3001_ARCYBER_COF.xls XLS spreadsheet
Bid_Abstract_W912HN18B3001_ARCYBER_COF.pdf PDF
18B3001vol2.PDF PDF
18B3001vol1.PDF PDF
amd7.pdf PDF
amd6.pdf PDF
18B3001vol1.PDF PDF
amd5.pdf PDF
18B3001vol1.PDF PDF
18B3001vol2.PDF PDF
18B3001vol4.PDF PDF
18B3001vol3.PDF PDF
W912HN-18-B-3001_VOL2_AMD5.pdf PDF
18B3001vol1.pdf PDF
18B3001vol3.pdf PDF
18B3001vol4.pdf PDF
18B3001vol2.pdf PDF
amd4.pdf PDF
W912HN-18-B-3001_VOL2_AMD3.pdf PDF
18B3001vol1.pdf PDF
amd3.pdf PDF
W912HN-18-B-3001_VOL1_AMD3.pdf PDF
18B3001vol2.pdf PDF
amd2.pdf PDF
W912HN-18-B-3001_VOL1_AMD1.pdf PDF
18B3001vol4.pdf PDF
W912HN-18-B-3001_VOL2_AMD2.pdf PDF
18B3001vol1.pdf PDF
18B3001vol1.pdf PDF
amd1.pdf PDF
18B3001vol3.pdf PDF
18B3001vol4.pdf PDF
18B3001vol2.pdf PDF
W912HN-18-B-3001_VOL1.pdf PDF
W912HN-18-B-3001_VOL2.pdf PDF
18B3001vol1.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET ID. TITLE

INDEX OF DRAWINGS - VOLUME 2

SHEET ID. SHEET ID.TITLE TITLE

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDKRW\Documents\FY17PN85794_PROJ_R18_K6ENDKRW.rvt

6/28/2018 12:54:41 PM

AP

R

IL

W

2H N

-1 8-

B-

XX

X

YY

Y

Au th or

XX

X

YY

Y

1-

-0

G-002

IN

D

EX

O

F D

R

AW

IN

G

S

Sa va nn ah

, G eo rg ia

Sa va nn ah

, G eo rg ia

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

XX

X

YY

Y

ISSUED FOR CONSTRUCTION

MH603 MECHANICAL SCHEDULES

MH701 HOT AND CHILLED WATER PIPING SCHEMATIC

MI001 HVAC CONTROLS LEGEND

MI002 HVAC CONTROLS POINTS - SCHEDULING INSTRUCTIONS

MI801 AHU-1 CONTROL SCHEMATIC AND LADDER DIAGRAM

MI802 AHU-2 & 3 CONTROL SCHEMATIC AND LADDER DIAGRAM

MI803 AHU-4 CONTROL SCHEMATIC AND LADDER DIAGRAM

MI804 DOAS-1 CONTROL SCHEMATIC AND LADDER DIAGRAM

MI804A ERV-1 & 2 CONTROL SCHEMATIC AND LADDER DIAGRAM

MI805 AHU-1 SEQUENCE-OF-OPERATION

MI806 AHU-2 & 3 SEQUENCE-OF-OPERATION

MI807 AHU-4 SEQUENCE-OF-OPERATION

MI808 DOAS-1 SEQUENCE-OF-OPERATION

MI808A ERV-1 & 2 SEQUENCE OF OPERATION

MI809 CONTROL VALVE & CONTROL DAMPER SCHEDULES

MI810 AHU-1 CONTROL POINTS SCHEDULE

MI811 AHU-2 & 3 CONTROL POINTS SCHEDULE

MI812 AHU-4 CONTROL POINTS SCHEDULE

MI813 DOAS-1 CONTROL POINTS SCHEDULE

MI814 MISC CONTROL SCHEMATICS

MI815 MISC CONTROLS AND SEQUENCE-OF-OPERATION

MI816 VAV TERMINAL UNIT & UNIT HEATER CONTROL POINTS SCHEDULE

MI817 MISC CONTROL POINTS SCHEDULES

MI818 FCU-1 & 2 CONTROL POINTS SCHEDULE

MI819 HYDRONIC HEATING HOT WATER SYSTEM CONTROL SCHEMATIC AND SEQUENCE-OF-OPERATION

MI820 HYDRONIC CHILLED WATER SYSTEM CONTROL SCHEMATIC AND SEQUENCE-OF-OPERATION

MI821 HYDRONIC CHILLED WATER SYSTEM CONTROL POINTS SCHEDULE

MI822 HYDRONIC HEATING HOT WATER SYSTEM CONTROL POINTS SCHEDULE

MI823 DOMESTIC HOT WATER CTRL SCHEMATIC, SEQUENCE OF OP, AND CTRL POINTS SCHED

MP101 HVAC HYDRONIC PIPING PLAN

MP102 HVAC HYDRONIC PIPING PLAN - PARTS A & C

MP103 HVAC HYDRONIC PIPING PLAN - PARTS B & D

E-001 ELECTRICAL LEGEND & GENERAL NOTES

E-002 ELECTRICAL ABBREVIATIONS & MOUNTING DIAGRAM

EG101 LIGHTNING PROTECTION PLAN - PARTS A & C

EG102 LIGHTNING PROTECTION PLAN - PARTS B & D

EG103 GROUNDING PLAN - PARTS A & C

EG104 GROUNDING PLAN - PARTS B & D

EG501 LIGHTNING PROTECTION SYSTEM DETAILS

EG502 MISCELLANEOUS GROUNDING DETAILS

EL101 LIGHTING PLAN - PARTS A & C

EL102 LIGHTING PLAN - PARTS B & D

EL401 LIGHTING PLAN - ENLARGED MECHANICAL EQUIPMENT PLATFORM

EL501 LIGHT FIXTURE SCHEDULE AND DETAILS

EL502 LIGHT FIXTURE DETAILS

EL503 LIGHT FIXTURE DETAILS

EL504 NOT USED

EL601 LIGHTING CONTROL STRATEGIES AND DETAILS

EP101 POWER PLAN - PARTS A & C

EP102 POWER PLAN - PARTS B & D

EP103 EQUIPMENT POWER PLAN - PARTS A & C

EP104 EQUIPMENT POWER PLAN - PARTS B & D

EP105 ROOF POWER PLAN - PARTS A & C

EP106 ROOF POWER PLAN - PARTS B & D

EP401 ENLARGED POWER PLANS

EP501 ELECTRICAL DETAILS

EP601 POWER ONE-LINE DIAGRAM

EP602 FEEDER & TRANSFORMER SCHEDULES

EP603 PANEL SCHEDULES

EP604 PANEL SCHEDULES

EP605 PANEL SCHEDULES

EP606 PANEL SCHEDULES

EP607 PANEL SCHEDULES

EY001 AUXILIARY SYSTEMS LEGEND & GENERAL NOTES

EY101 AUXILIARY SYSTEMS PLAN - PARTS A & C

EY102 AUXILIARY SYSTEMS PLAN - PARTS B & D

EY601 AUXILIARY SYSTEMS DIAGRAMS

T-001 TELECOMMUNICATIONS LEGEND & GENERAL NOTES

T-101 TELECOMMUNICATION PLAN - PARTS A & C

T-102 TELECOMMUNICATION PLAN - PARTS B & D

T-103 TELECOMMUNICATION NON-SECURE PATHWAY PLAN - PARTS A & C

T-104 TELECOMMUNICATION NON-SECURE PATHWAY PLAN - PARTS B & D

T-105 SIPRNET PATHWAY PLAN - PARTS A & C

T-106 SIPRNET PATHWAY PLAN - PARTS B & D

T-401 ENLARGED TELECOMMUNICATION PLANS

T-501 TELECOMMUNICATION DETAILS - CABLE TRAYS

T-502 TELECOMMUNICATION DETAILS - OUTLETS & LABELING

T-601 TELECOMMUNICATION ONE-LINE DIAGRAMS

T-602 TELECOMMUNICATION ELEVATION DIAGRAM - T.E.R. B103

T-603 TELECOMMUNICATION ELEVATION DIAGRAM - T.R. B116

T-604 TELECOMMUNICATION ELEVATION DIAGRAM - NERD SERVER C102

A-602 PARTITION TYPES

A-603 DOOR SCHEDULE AND DETAILS 1

A-604 DOOR SCHEDULE AND DETAILS 2

A-604A ESS DOOR DETAILS 1

A-604B ESS DOOR DETAILS 2

A-604C ESS DOOR DETAILS 3

A-605 DOOR DETAILS

A-606 DOOR DETAILS

A-607 DOOR DETAILS

A-608 WINDOW TYPES

A-609 WINDOW DETAILS 1

A-609A WINDOW DETAILS 2

A-610 LOUVER SCHEDULE AND LOUVER DETAILS

A-620 FINISH SCHEDULE

A-701 LIFE SAFETY PLAN

A-702 LIFE SAFETY ANALYSIS

A-800 AIR BARRIER BOUNDARY PLAN

A-801 AIR BARRIER SECTIONS

A-802 AIR BARRIER DETAILS 1

A-803 AIR BARRIER DETAILS 2

A-804 AIR BARRIER DETAILS 3

A-805 AIR BARRIER DETAILS 4

A-806 AIR BARRIER DETAILS 5

I-101A FURNITURE PLAN - AREA A

I-101B FURNITURE PLAN - AREA B

I-101C FURNITURE PLAN - AREA C

I-101D FURNITURE PLAN - AREA D

I-111A FINISH PLAN - AREA A

I-111B FINISH PLAN - AREA B

I-111C FINISH PLAN - AREA C

I-111D FINISH PLAN - AREA D

I-501 SIGNAGE SCHEDULE & DETAILS

I-511 SIGNAGE TYPICALS 1

I-512 SIGNAGE TYPICALS 2

I-601 ROOM FINISH SCHEDULE

I-611 FINISH LEGEND

I-612 FINISH DETAILS

FA001 FIRE ALARM LEGEND AND OPERATIONS MATRIX

FA101 FIRE ALARM & MASS NOTIFICATION SYSTEMS PLAN - PARTS A & C

FA102 FIRE ALARM & MASS NOTIFICATION SYSTEMS PLAN - PARTS B & D

FA601 FIRE ALARM & MNS ONE-LINE DIAGRAM

FX001 FIRE PROTECTION LEGEND AND GENERAL NOTES

FX101 FIRE PROTECTION FLOOR PLAN - OVERALL

FX102 FIRE PROTECTION FLOOR PLAN - AREA A

FX103 FIRE PROTECTION FLOOR PLAN - AREA B

FX104 FIRE PROTECTION FLOOR PLAN - AREA C

FX105 FIRE PROTECTION FLOOR PLAN - AREA D

FX501 FIRE PROTECTION DETAILS I

FX502 FIRE PROTECTION DETAILS II

FX503 FIRE PROTECTION DETAILS III

P-001 PLUMBING LEGEND

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-503 PLUMBING DETAILS

P-504 PLUMBING DETAILS

PL101 PLUMBING FLOOR PLAN - SANITARY SEWER

PL102 PLUMBING FLOOR PLAN - DOMESTIC WATER

PL103 PLUMBING FLOOR PLAN - ROOF DRAINAGE

PL601 PLUMBING SCHEDULES

M-001 HVAC LEGEND

MH101 HVAC FLOOR PLAN - OVERALL

MH102 HVAC FLOOR PLAN - PARTS A & C

MH103 HVAC FLOOR PLAN - PARTS B & D

MH104 HVAC FLOOR PLAN - PARTS A & C (AIRFLOWS & DEVICES)

MH105 HVAC FLOOR PLAN - PARTS B & D (AIRFLOWS & DEVICES)

MH106 HVAC ROOF PLAN

MH107 HVAC THERMOSTAT & SENSOR PLAN

MH301 HVAC SECTIONS

MH302 HVAC SECTIONS

MH303 HVAC SECTIONS

MH304 HVAC SECTIONS

MH305 HVAC SECTIONS

MH401 HVAC ENLARGED PLANS

MH501 HVAC DETAILS

MH502 HVAC DETAILS

MH503 HVAC DETAILS

MH504 HVAC DETAILS

MH505 HVAC DETAILS

MH506 HVAC BRACING DETAILS

MH507 HVAC DETAILS

MH601 MECHANICAL SCHEDULES

MH602 MECHANICAL SCHEDULES

G-001 COVER SHEET

G-002 INDEX OF DRAWINGS

G-003 GENERAL NOTES, ABBREVIATIONS

S-001 GENERAL STRUCTURAL NOTES

S-002 GENERAL STRUCTURAL NOTES

S-003 GENERAL STRUCTURAL NOTES

SB101 COMPOSITE FOUNDATION PLAN

SB101A FOUNDATION PLAN - AREA A

SB101B FOUNDATION PLAN - AREA B

SB101C FOUNDATION PLAN - AREA C

SB101D FOUNDATION PLAN - AREA D

SB102 LOADING DOCK PLAN

SB103 PEDESTRIAN BRIDGE PLAN

SB301 FOUNDATION SECTIONS

SB302 FOUNDATION SECTIONS

SB303 FOUNDATION SECTIONS

SB501 FOUNDATION DETAILS

SB601 FOUNDATION SCHEDULES

SF101 COMPOSITE ROOF PLAN

SF101A ROOF PLAN - AREA A AND C

SF101B ROOF PLAN - AREA B AND D

SF201 FRAMING ELEVATIONS

SF202 FRAMING ELEVATIONS

SF203 FRAMING ELEVATIONS

SF204 FRAMING ELEVATIONS

SF205 FRAMING ELEVATIONS

SF206 FRAMING ELEVATIONS

SF207 FRAMING ELEVATIONS

SF208 FRAMING ELEVATIONS

SF301 FRAMING SECTIONS

SF302 FRAMING SECTIONS

SF303 FRAMING SECTIONS

SF304 FRAMING SECTIONS

SF305 FRAMING SECTIONS

SF501 FRAMING DETAILS

SF502 FRAMING DETAILS

SF601 COLUMN SCHEDULES

A-101 COMPOSITE FLOOR PLAN

A-101A FLOOR PLAN -AREA A

A-101B FLOOR PLAN -AREA B

A-101C FLOOR PLAN -AREA C

A-101D FLOOR PLAN -AREA D

A-101E FLOOR PLAN - MECHANICAL EQUIPMENT PLATFORMS AREA C & D

A-101F CLERESTORY PLAN

A-102 DIMENSION PLAN

A-102A DIMENSION PLAN- LATRINES/BREAKROOM

A-103 SECRET OPEN STORAGE AREA FLOOR PLAN

A-104 ROOF PLAN

A-105 REFLECTED CEILING PLAN -PART A

A-106 REFLECTED CEILING PLAN -PART B

A-107 REFLECTED CEILING PLAN -PART C

A-108 REFLECTED CEILING PLAN -PART D

A-109 REFLECTED CEILING PLAN - MECH. EQUIPMENT PLATFORM AREAS C & D

A-201 NORTH ELEVATIONS PART A AND B

A-202 SOUTH ELEVATIONS PART C AND D

A-203 EAST AND WEST ELEVATIONS

A-301 BUILDING CROSS SECTION

A-302 BUILDING LONGITUDINAL SECTION

A-310 WALL SECTIONS

A-311 WALL SECTIONS

A-312 WALL SECTIONS

A-313 WALL SECTIONS

A-314 WALL SECTIONS

A-315 WALL SECTIONS

A-316 WALL SECTIONS

A-317 WALL SECTIONS

A-400 ENLARGED PLANS & INTERIOR ELEVATIONS

A-401 ENLARGED PLANS & INTERIOR ELEVATIONS

A-500 ROOF DETAILS 1

A-501 ROOF DETAILS 2

A-502 ROOF DETAILS 3

A-503 ROOF DETAILS 4

A-504 ROOF DETAILS 5

A-520 CEILING DETAILS

A-521 INTERIOR DETAILS I

A-522 INTERIOR DETAILS 2

A-523 INTERIOR DETAILS 3

A-530 EXTERIOR DETAILS

A-531 EXTERIOR DETAILS 2

A-540 MISCELLANEOUS DETAILS

A-601 PARTITION TYPES

A-601A PARTITION TYPES

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 8

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 8

B

9 10

C

PTDWR

LPS

SD

SD

MG

MG

PTDWR

LPS LPS

LB

SCSCR

TP TP

SCSCR

SCSCR

TPADA

SHSH SH

GB03 FSS

TTD TTD TTD TTD

TSCD TSCDTSCD

GB02

GB01

TSCD

A-400

7 9

A-400

SND SND SND SND

B

C

LPS

LPS LPS

LPSLB

PTDWR

SCSCR SCSCR SCSCR SCSCR

TP TP TPSH

FSS

GB03

SH SH SH

PTDWR

PTDWR

SD

MG

MG

SD

MG

SD

MG

MG

TPABA

TTD TTD TTD TTD

TTD TTD TTD TTD

GB01

GB02TSCD TSCD TSCD TSCD

A-401 64

A-401

9 10 11

SMHD

A-401

A-401

D

6 87

SMHD

SMHD

A-401

A-401

1. SLOPE SLABS TO FLOOR DRAINS, TYP.

2. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL

TOILET ACCESSORIES.

3. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL

WALL HUNG FIXTURES (LAVATORIES, URINALS, ETC.).

4. WOMEN'S & MEN'S SHOWER AREAS SHALL BE FULL HEIGHT CERAMIC

WALL TILE AS INDICATED. ALL OTHER AREAS SHALL HAVE A 4'-0" WALL TILE

WAINSCOT, TYP. TERMINATE THE 4'-0" HIGH CERAMIC WALL TILE WAINSCOT

WITH A BULLNOSE.

1. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN

CENTERLINES, UNLESS NOTED OTHERWISE (U.N.O.).

2. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.

3. REFERENCE SHEETS A-601, A-601A & A- A-602 FOR PARTITION TYPES.

4. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR

TYPICAL TILE SIZE AND PATTERNS.

B.O. REFLECTIVE

SURFACE

MG

TOWEL

PIN

(TPABA)

SHOWER

CURTAIN &

ROD

(SCSR)

24" X 36"

MIRROR (MG)

FOLDING

SHOWER

SEAT (FSS1)

SHOWER HEAD

AND HAND HELD

UNIT

SURFACE MOUNTED

GRAB BARS FOR

SHOWER (GB03)

WATER CLOSET AND

GRAB BARS (GB01)

(GB02)

WATER CLOSET AND

GRAB BARS (GB01) (GB02)

WALL-MOUNTED

LAVATORY

HC- ABA

COMPLIANT

TTD

SOAP

DISPENSE

R

(SD)

SOAP

DISH

(SH)

WATER

COOLER

ACCESSIBLE / BI-LEVEL ELECTRIC

WATER COOLER (INSTALL BOTTLE

FILLER WITHIN ACCESSIBLE

REACH)

LAVATORYSANITARY

NAPKIN

DISPOSAL (SND)

SND

SND

3' -4

" M

AX

2' -1

0"

2' -3

9"

8" 7"

4' -0

/2

3' -4

" T O

BO

TT

O M

O F

R

EF

LE

C

TI

VE

SU

R

FA

C

E

" M

IN

. T

O

" M

AX

. A

.F .F

6' -6

18" MIN.

40"-42" MAX.

2' -0

"-1

9"

"-1

9"

17" MIN.

" M

AX

" M

IN

6" MAX.

3' -0

1'-2" 1' -5

M

AX

6" MAX 8" MIN.

17"-19"

3' -3

2' -9

9" M

IN

2' -6

4' -0

18" TYP.

CONTROL

S

UG

TOILET SEAT COVER

DISPENSER (TSCD)

URINALS

1'-2" 1' -1

1"

TOWEL

PIN

(TP)

5' -0

HC- ABA

COMPLIAN

T

PAPER TOWEL

DISPENSER / WASTE

RECEPTACLE (PTD)

4' -0

M

AX

1' - 0" MAX. 3' - 6" MIN.

1'

3/

4"

UTILITY SHELF WITH

RAG HOOKS AND

BROOM HOLDERS

(SMHD)

5'

6"

1' - 0"

2"

CENTERLINE

OF SHOWER

SEAT

7 1/2"

3'

6"

4'

0"

LPSLPS LPS

PTDWR

LB

4" HIGH CONCRETE BASE WITH TILE FINISH

ON EACH EXPOSED FACE

9'

0"

4'

0"

FSS SCSCR SCSCR SCSCR

TPADA

SH

TP

SH

TP

SCSCRSCSCR SCSCR

SD

MG

4'

0"

9'

0"

MG MG MG

SD SD

4'

0"

9'

0"

PTDWR

9'

0"

4'

0"

PTDWR

9'

0"

4'

0"

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt

6/27/2018 5:28:59 PM

AP

R

IL

W

2H N

-1 8-

B-

P.

S

U

LL

IV

AN

Au th or

T.

D

C

AT

C

O D

E

A-400

EN

LA

R G

ED

P

LA

N

S

IN

TE

R

IO

R E

LE

VA

TI

O

N S

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

XX

X

YY

Y

ISSUED FOR CONSTRUCTION

WOMENS ROOM B1051 MENS ROOM B1082

BREAKROOM B107/JANITORS CLOSET B1113 JANITORS CLOSETS C101 AND D1034

GENERAL NOTES

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

TOILET & FIXTURE ACCESSORIES SCHEDULE

Accessory Description Type Mark MOUNTING HEIGHT

FOLDING ADA SHOWER SEAT FSS SEE DETAILS FOR

MOUNTING HEIGHT

GRAB BAR 36" GB01 34" A.F.F. CENTERLINE

OF BAR

Grab Bars 42" GB02 34" A.F.F. centerline of bar

ABA 1 1/2" DIA. STAINLESS STEEL

HORIZONTAL TWO WALL BAR

GB03 34" A.F.F. CENTERLINE

OF BAR

SOLID PLASTIC PEDESTAL BENCH LB

Personal Storage Locker - Single Door LPS 12" X 15" X 72" SLOPED

TOP

18"W 36"H MIRROR WITH STAINLESS

STEEL FRAME

MG BOTTOM OF GLASS 40"

AFF

SEMI-RECESSED PAPER TOWEL

DISPENSER WASTE RECEPTACLE

PTDWR 48" A.F.F.

SHOWER CURTAIN & ROD SCSCR

WALL MOUNTED SOAP DISPENSER SD TOP 46" A.F.F.

SOAP HOLDER SH TOP 40' A.F.F.

UTILITY SHELF WITH RAG HOOKS

AND BROOM HOLDERS

SMHD 66" A.F.F.

SANITARY NAPKIN DISPOSER SND SURFACE MOUNTED

TOP 30" A.F.F.

TOWEL PIN TP 66" A.F.F.

TOWEL PIN ABA TPABA 44 A.F.F.

TOWEL PIN ADA TPADA

TOILET SEAT COVER DISPENSER -

SURFACE

TSCD 48" A.F.F.

TOILET TISSUE DISPENSER - 2 ROLL,

SURFACE

TTD 20" A.F.F

DRAWING NOTES

WOMENS ROOM B105 ELEV. A5 WOMENS ROOM B105 ELEV. B6

WOMENS ROOM B105 ELEV. C7

WOMENS ROOM B105 ELEV. D8

WOMENS ROOM B105 ELEV. E9

WOMENS ROOM B105 ELEV. F10

FIXTURE MOUNTING HEIGHTS

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 9

1. SLOPE SLABS TO FLOOR DRAINS, TYP.

2. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL

TOILET ACCESSORIES.

3. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL

WALL HUNG FIXTURES (LAVATORIES, URINALS, ETC.).

4. WOMEN'S & MEN'S SHOWER AREAS SHALL BE FULL HEIGHT CERAMIC

WALL TILE AS INDICATED. ALL OTHER AREAS SHALL HAVE A 4'-0" WALL TILE

WAINSCOT, TYP. TERMINATE THE 4'-0" HIGH CERAMIC WALL TILE WAINSCOT

WITH A BULLNOSE.

B.O. REFLECTIVE

SURFACE

MG

TOWEL

PIN

(TPABA)

SHOWER

CURTAIN &

ROD

(SCSR)

24" X 36"

MIRROR (MG)

FOLDING

SHOWER

SEAT (FSS1)

SHOWER HEAD

AND HAND HELD

UNIT

SURFACE MOUNTED

GRAB BARS FOR

SHOWER (GB03)

WATER CLOSET AND

GRAB BARS (GB01)

(GB02)

WATER CLOSET AND

GRAB BARS (GB01) (GB02)

WALL-MOUNTED

LAVATORY

HC- ABA

COMPLIANT

TTD

SOAP

DISPENSE

R

(SD)

SOAP

DISH

(SH)

WATER

COOLER

ACCESSIBLE / BI-LEVEL ELECTRIC

WATER COOLER (INSTALL BOTTLE

FILLER WITHIN ACCESSIBLE

REACH)

LAVATORYSANITARY

NAPKIN

DISPOSAL (SND)

SND

SND

3' -4

" M

AX

2' -1

0"

2' -3

9"

8" 7"

4' -0

/2

3' -4

" T O

BO

TT

O M

O F

R

EF

LE

C

TI

VE

SU

R

FA

C

E

" M

IN

. T

" M

AX

. A

.F .F

6' -6

18" MIN.

40"-42" MAX.

2' -0

"-1

9"

"-1

9"

17" MIN.

" M

AX

" M

IN

6" MAX.

3' -0

1'-2" 1' -5

M

AX

6" MAX 8" MIN.

17"-19"

3' -3

2' -9

9" M

IN

2' -6

4' -0

18" TYP.

CONTROL

S

UG

TOILET SEAT COVER

DISPENSER (TSCD)

URINALS

1'-2" 1' -1

1"

TOWEL

PIN

(TP)

5' -0

HC- ABA

COMPLIAN

T

PAPER TOWEL

DISPENSER / WASTE

RECEPTACLE (PTD)

4' -0

M

AX

1' - 0" MAX. 3' - 6" MIN.

1'

3/

4"

UTILITY SHELF WITH

RAG HOOKS AND

BROOM HOLDERS

(SMHD)

5'

6"

1' - 0"

2"

CENTERLINE

OF SHOWER

SEAT

7 1/2"

3'

6"

1. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN

CENTERLINES, UNLESS NOTED OTHERWISE (U.N.O.).

2. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.

3. REFERENCE SHEETS A-601, A-601A & A- A-602 FOR PARTITION TYPES.

4. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR

TYPICAL TILE SIZE AND PATTERNS.

LPS

LPS LPS

LPS

LB

PTDWR

MG

SD

4'

0"

9'

0"

4" HIGH CONCRETE BASE WITH TILE FINISH

ON EACH EXPOSED FACE

4'

0"

9'

0" MG

SD PTDWR

SCSCR SCSCR SCSCR SCSCR

TP TP TP

TPABA

SHSHSH

FSS

4'

0"

9'

0"

PTDWR

PTDWR

SD

PTDWR PTDWR

PTDWR

4'

0"

9'

0"

MG MG MG MG MG

SD SD SDSD

PTDWR

4'

0"

9'

0"

A-540

A-540

A-540

8'

0"

SMHD

D

SMHD

8'

0"

SMHD

8'

0"

A-801

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt

6/27/2018 5:29:08 PM

AP

R

IL

W

2H N

-1 8-

B-

P.

S

U

LL

IV

AN

Au th or

T.

D

C

AT

C

O D

E

A-401

EN

LA

R G

ED

P

LA

N

S

IN

TE

R

IO

R E

LE

VA

TI

O

N S

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

C he ck er

ISSUED FOR CONSTRUCTION

GENERAL NOTES

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

DRAWING NOTES

TOILET & FIXTURE ACCESSORIES SCHEDULE

Accessory Description Type Mark MOUNTING HEIGHT

FOLDING ADA SHOWER SEAT FSS SEE DETAILS FOR

MOUNTING HEIGHT

GRAB BAR 36" GB01 34" A.F.F. CENTERLINE

OF BAR

Grab Bars 42" GB02 34" A.F.F. centerline of bar

ABA 1 1/2" DIA. STAINLESS STEEL

HORIZONTAL TWO WALL BAR

GB03 34" A.F.F. CENTERLINE

OF BAR

SOLID PLASTIC PEDESTAL BENCH LB

Personal Storage Locker - Single Door LPS 12" X 15" X 72" SLOPED

TOP

18"W 36"H MIRROR WITH STAINLESS

STEEL FRAME

MG BOTTOM OF GLASS 40"

AFF

SEMI-RECESSED PAPER TOWEL

DISPENSER WASTE RECEPTACLE

PTDWR 48" A.F.F.

SHOWER CURTAIN & ROD SCSCR

WALL MOUNTED SOAP DISPENSER SD TOP 46" A.F.F.

SOAP HOLDER SH TOP 40' A.F.F.

UTILITY SHELF WITH RAG HOOKS

AND BROOM HOLDERS

SMHD 66" A.F.F.

SANITARY NAPKIN DISPOSER SND SURFACE MOUNTED

TOP 30" A.F.F.

TOWEL PIN TP 66" A.F.F.

TOWEL PIN ABA TPABA 44 A.F.F.

TOWEL PIN ADA TPADA

TOILET SEAT COVER DISPENSER -

SURFACE

TSCD 48" A.F.F.

TOILET TISSUE DISPENSER - 2 ROLL,

SURFACE

TTD 20" A.F.F

FIXTURE MOUNTING HEIGHTS

MENS ROOM B108 ELEV. A1

MENS ROOM B108 ELEV. B2

MENS ROOM B108 ELEV. C3

MENS ROOM B108 ELEV. D4

MENS ROOM B108 ELEV. F5

MENS ROOM B108 ELEV. G6

BREAKROOM B107 ELEV. A7

JANITORS CLOSET B111 ELEV. A8

JANITORS CLOSET C101 ELEV. A9

JANITORS CLOSET D103 ELEV. A10

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 8

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

8' - 0"

3'

0" 4'

0"

4'

0" 4'

0"

5"3' - 4"6"3' - 4"5"

" F

R

AM

E H

EI

G

H T

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

CONTRACTOR FURNISHED

CONTRACTOR INSTALLED

PALLET STORAGE RACKS

FOOT PLATE SIZE TO BE A

MINIMUM OF 5" X 7" (35 SQ. INCHES)

WITH (4) 1/2 INCH DIAMETER

ANCHOR BOLTS (TYPICAL)

PALLET RACK BEAM WITH

HEAVY DUTY BEAM END

CONNECTORS

NOTE:

PROVIDE TWO HEAVY DUTY

CROSS BARS FOR EACH

PALLET

FINISHED FLOOR

3' - 6" 1' - 0"

4'

0" 4'

0"

4'

0" 3'

0"

4' - 0"

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

" F

R

AM

E H

EI

G

H T

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

4000 LBS MAX.

TOTAL WEIGHT

INCLUDES

PALLET

CONTRACTOR FURNISHED

CONTRACTOR INSTALLED

PALLET STORAGE RACKS

FOOT PLATE SIZE TO BE A

MINIMUM OF 5" X 7" (35 SQ. INCHES)

WITH (4) 1/2 INCH DIAMETER

ANCHOR BOLTS (TYPICAL)

PROVIDE RIGID ROW AND

RIGID WALL SPACERS

"NOTE:

PROVIDE TWO HEAVY DUTY

CROSS BARS FOR EACH

PALLET

FINISHED FLOOR

EQUAL EQUAL

2' - 0 3/4"

4"

1' - 4 3/4"

4"

3'

6" 9'

4"

1'

9"

1'- 4"1'- 4"

2' - 2" 2' - 2"

3" X 1/2" THICK STEEL FLAT

SOLID BAR STOCK SIDE RAILS

4" X 7 3/4" X 1/2" THICK STEEL

BENT PLATE LADDER SUPPORT

WITH 5/8" DIAMETER EXPANSION

BOLTS. SUPPORTS SPACED AT

48" O.C. VERTICALLY

LADDER RUNGS- 3/4" DIAMETER

ROUND BARS AT 12" O.C. VERTICALLY

MAXIMUM (TYPICAL)

4" X 4" X 1/2" THICK STEEL ANGLE

WITH 5/8" DIAMETER EXPANSION BOLT

FINISHED FLOOR

C O

N

TR

AC

TO

R T

O V

ER

IF

Y H

EI

G

H T

AT

R

O O

F H

AT

C

H P

R

IO

R T

O F

AB

R

IC

AT

IO

N

R = 1"

FRONT VIEW TOP VIEW

SIDE VIEW

2" 3"

3" 2"

2" 2"

4' -0

" A .F

.F

3/8" DIAMETER

STAINLESS STEEL

ROD

3/8" DIAMETER

STAINLESS STEEL

ROD

3/8" DIAMETER

STAINLESS STEEL

ROD

3/8" DIAMETER

STAINLESS STEEL

ROD

INTERIOR

FACE OF VAULT

WALL

LINE OF VAULT

WALL

LINE OF VAULT

WALL

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt

6/27/2018 4:24:25 PM

AP

R

IL

W

2H N

-1 8-

B-

P.

S

U

LL

IV

AN

Au th or

T.

D

C

AT

C

O D

E

A-522

IN

TE

R

IO

R D

ET

AI

LS

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

C he ck er

ISSUED FOR CONSTRUCTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 9

TYPICAL PALLET STORAGE FRONT ELEVATION1

TYPICAL PALLET STORAGE SIDE ELEVATION2

1 2 42

SCALE: 1/2"=1'-0"

1 2 42

SCALE: 1/2"=1'-0"

LADDER 2 ,3 AND GUARDRAIL ELEVATIONS3

FACE OF WALL

FINISHED

FLOOR

1 1/2" DIAMETER GUARDRAIL

(TYPICAL)

3" X 6" X 1/2" STEEL

WALL CONNECTION

PLATE WITH (2) 3/8"

DIAMETER EXPANSION

BOLTS (TYPICAL)

4" X 4" X 3/8" STEEL ANGLE

TOE BOARD WITH 3/8" DIAMETER

EXPANSION BOLTS AT 16" O.C.

3" X 1/2" THICK STEEL FLAT

SOLID BAR STOCK SIDE RAILS

4" X 7 3/4" X 1/2" THICK STEEL

BENT PLATE LADDER SUPPORT

WITH 5/8" DIAMETER EXPANSION

BOLTS. SUPPORTS SPACED AT

48" O.C. VERTICALLY

LADDER RUNGS- 3/4" DIAMETER

ROUND BARS AT 12" O.C. VERTICALLY

MAXIMUM (TYPICAL)

LADDER EXTENSION GUARDRAIL RAIL RETURNS WELDED TO

LADDER EXTENSIONS (TYPICAL)

4" X 4" X 1/2" THICK STEEL ANGLE

WITH 5/8" DIAMETER EXPANSION BOLT

1 2 42

SCALE: 1/2"=1'-0"

01 2 42

SCALE: 1/2"=1'-0"

SBP- STRUCTURAL BARRIER POST

LADDER 1- LADDER TO ROOF4

1 2 42

SCALE: 1/2"=1'-0"

ARMS ROOM ANCHOR DETAIL5

6"6"

SCALE: 3"=1'-0"

04 2

A.

F.

F.

2'

8" 5'

4"

6' - 0"

A

A-609

A-609

A-609

A-609

A-801

10' - 0"

A.

F.

F.

2'

8" 5'

4"

B

A-609

A-609

A-609

5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"

2'

3/

4" 4'

1/ 2"

2'

/4

C

A-609A

A-609A

A-609A

A-803

5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"

2'

3/

4" 4'

1/ 2"

2'

/4

D

A-609A

A-609A

A-609A

3' - 9" 3' - 9"

2'

/4

4'

1/

2" 2'

3/ 4"

E

A-609

A-609A

A-609

" A

.F .F

/4

4'

0" 3'

1/ 4"

4'

1/

2"

7' - 6"

3' - 9" 3' - 9"

F

A-609

A-609

A-609

5' - 2 3/4" 6' - 2 1/2" 5' - 2 3/4"

" A

.F .F

4'

0"

3'

1/

4" 4'

3/ 4"

16' - 8"

G

A-609

A-609

A-609

A-801

TOS 2

23' - 6"

15' - 0"

" A

.F .F

A-609A

A-609A

A-609A

A-801

20' - 0"

A-609A

A-609A

A-609A

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDPJS\Documents\FY17PN85794_ARCH_R18_K6ENDPJS.rvt

6/27/2018 4:24:48 PM

AP

R

IL

W

2H N

-1 8-

B-

P.

S

U

LL

IV

AN

Au th or

T.

D

C

AT

C

O D

E

A-608

W

IN

D O

W T

YP

ES

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

XX

X

YY

Y

ISSUED FOR CONSTRUCTION

H I

WINDOW TYPES

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

FIRE ALARM AND MASS NOTIFICATION SYMBOLS

FIRE ALARM MANUAL PULL STATION.

FACP

MNS

LOC

F

DH

RA

RM

S

CO

DOOR HOLDER WALL MAGNET. RELEASES DOOR UPON FIRE ALARM SYSTEM

ACTIVATION OR LOSS OF BUILDING NORMAL POWER.

FIRE ALARM STROBE (CLEAR), WALL MOUNTED. WHERE PRESENT, NUMBER

INDICATES INTENSITY. WHERE NOT PRESENT, INTENSITY SHALL BE 30 CANDELA

(CD). "WP" INDICATES WEATHERPROOF.

MASS NOTIFICATION SYSTEM STROBE (AMBER), WALL MOUNTED. WHERE PRESENT,

NUMBER INDICATES INTENSITY. WHERE NOT PRESENT, INTENSITY SHALL BE 30

CANDELA (CD). "WP" INDICATES WEATHERPROOF.

MASS NOTIFICATION/ PAGING SYSTEM SPEAKER, CEILING MOUNTED.

MASS NOTIFICATION/ PAGING SYSTEM SPEAKER, WALL MOUNTED.

'WP' INDICATES WEATHERPROOF.

HEAT DETECTOR

SMOKE DETECTOR

CARBON MONOXIDE DETECTOR

DUCT SMOKE DETECTOR

SPRINKLER SYSTEM FLOW SWITCH

SPRINKLER SYSTEM TAMPER SWITCH

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

MASS NOTIFICATION SYSTEM CONTROL PANEL

FLUSH-MOUNTED MASS NOTIFICATION SYSTEM LOCAL OPERATOR CONSOLE

FIRE ALARM ADDRESSABLE RELAY MODULE

FIRE ALARM ANNUNCIATOR HORN. "WP" INDICATES WEATHERPROOF.

MASS NOTIFICATION TRANSMITTER ANTENNA

A AMPERE

AFF ABOVE FINISHED FLOOR

C CONDUIT

COR CONTRACTING OFFICER'S REPRESENTATIVE

CU COPPER

FACP FIRE ALARM CONTROL PANEL

GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

FADS FIRE ALARM AND DETECTION SYSTEM

FEB FIRE EXTINGUISHER BRACKET

FEC FIRE EXTINGUISHER CABINET

HZ HERTZ

IDS INTRUSION DETECTION SYSTEM

LED LIGHT EMITTING DIODE

MFR MANUFACTURER

MH MOUNTING HEIGHT

MNS MASS NOTIFICATION SYSTEM

NEC NATIONAL ELECTRICAL CODE

NO. NUMBER

PAF PAINTED AFTER FABRICATION

PIR PASSIVE INFRARED

R/W RACEWAY

SPD SURGE PROTECTIVE DEVICE

TR TRANSFORMER

TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR

TYP TYPICAL

UL UNDERWRITERS LABORATORY

UOI UNLESS OTHERWISE INDICATED

UON UNLESS OTHERWISE NOTED

V VOLT

W, WP WEATHERPROOF

1. CONDUITS SHALL BE CONCEALED IN CEILINGS AND

WALLS, EXCEPT AS SHOWN OTHERWISE.

2. MOUNT OUTLET BOXES SO THAT NONE OCCUR

BACK TO BACK IN WALLS.

3. SEAL PENETRATIONS THROUGH FLOORS OR FIRE

WALLS TO MAINTAIN THE INTEGRITY OF THE FIRE

AND ACOUSTIC RATINGS OF THE WALLS AND FLOORS.

4. RACEWAYS CROSSING STRUCTURAL EXPANSION

JOINTS OR SEISMIC JOINTS SHALL BE PROVIDED

WITH SUITABLE EXPANSION FITTINGS OR OTHER

SUITABLE MEANS TO COMPENSATE FOR THE BUILDING

EXPANSION AND CONTRACTION AND TO PROVIDE

FOR CONTINUITY OF GROUNDING.

5. FOR TYPICAL MOUNTING HEIGHTS, SEE E-001.

GENERAL NOTES ABBREVIATIONS

FIRE ALARM/MASS NOTIFICATION

SYSTEMS OPERATIONS MATRIX

NOTES, FIRE ALARM & MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATION:

1A. SUBSEQUENT ACTUATION OF OTHER INITIATING DEVICES OR SUPERVISORY SIGNALS AFTER THE INITIAL ALARM OR SUPERVISORY SIGNAL HAS BEEN SILENCED SHALL CAUSE

THE NOTIFICATION APPLIANCES TO REACTIVATE.

1B. IF AN AUDIBLE TROUBLE SIGNAL HAS BEEN SILENCED, IT SHALL COMPLY WITH THE FOLLOWING:

i. THE AUDIBLE TROUBLE SHALL RE-SOUND EVERY 24 HOURS OR LESS UNTIL FAULT CONDITIONS ARE RESTORED TO NORMAL.

ii. THE RE-SOUNDED AUDIBLE TROUBLE SIGNAL SHALL SOUND UNTIL IT IS MANUALLY SILENCED OR ACKNOWLEDGED.

iii. THE RE-SOUNDED AUDIBLE TROUBLE SIGNAL SHALL ALSO BE AUTOMATICALLY RETRANSMITTED TO THE BASE FIRE DEPARTMENT.

1C. WHEN THE SILENCE SWITCH IS LEFT IN THE "OFF" POSITION AND THERE IS NO ALARM, SUPERVISORY, OR TROUBLE SIGNAL, AN AUDIBLE TROUBLE SIGNAL AND A VISUAL INDICATOR SHALL BE ACTIVATED UNTIL THE SWITCH IS RESTORED TO ITS NORMAL POSITION.

2. THE MASS NOTIFICATION SYSTEM SHALL TEMPORARILY INTERRUPT THE FIRE ALARM AUDIBLE MESSAGE AND VISUAL NOTIFICATION APPLIANCES DURING SIMULTANEOUS FIRE AND MASS EVACUATION EVENTS. ALL OTHER FEATURES OF THE FIRE ALARM SYSTEM SHALL FUNCTION PROPERLY. DURING THE INTERRUPTION OF THE FIRE ALARM AUDIBLE AND VISUAL SIGNALS, A DISTINCT SUPERVISORY SIGNAL SHALL BE ANNUNCIATED (BOTH AUDIBLY AND VISUALLY) AT THE FACP (AND REMOTE FIRE ALARM ANNUNCIATORS) AND SHALL

BE TRANSMITTED TO THE CENTRAL FIRE ALARM SYSTEM.

3. DUCT DETECTORS IN ALARM MODE SHALL CAUSE THE AIR HANDLER UNIT PROTECTED BY THE DETECTOR TO SHUT DOWN AND SHALL CAUSE THE ASSOCIATED SMOKE DAMPERS TO CLOSE. OTHER AIR HANDLERS PROTECTED BY NON-ALARMED DUCT DETECTORS SHALL REMAIN IN OPERATION. FOR DUCT SMOKE DETECTORS NOT READILY ACCESSIBLE

AND/OR MOUNTED GREATER THAN 6'-0" AFF, PROVIDE A REMOTE TEST SWITCH.

4. SEE FA101 AND FA102 FOR LOCATION OF DOORS TO BE UNLOCKED UPON FIRE ALARM ACTIVATION.

D

IS

PL

AY

M

ES

SA

C E

O N

F

AC

P

D

IS

PL

AY

M

ES

SA

G

E O

N F

IR

E

AL

AR

M A

N N

U N

C

IA

TO

R

R

EC

O R

D E

VE

N

T

IN

T H

E H

IS

TO

R Y

LO

G

TR

AN

SM

IT

A

LA

R M

T O

C

EN

TR

AL

F

IR

E

AL

AR

M

S

YS

TE

M

SM

IT

S U

PE

R

VI

SO

R Y

SI

G

N

AL

T O

C

EN

TR

AL

F

IR

E

AL

AR

M

S

YS

SM

IT

T R

O U

BL

E

SI

G

N

AL

T O

C

EN

TR

AL

F

IR

E

AL

AR

M

S

YS

AC

TI

VA

TE

C

LE

AR

F

IR

E

AL

AR

M N

O

TI

FI

C

AT

IO

N S

TR

O

BE

S

AC

TI

VA

TE

A M

BE

R

M

AS

S N

O

TI

FI

C

AT

IO

N S

TR

O

BE

S

BR

O

AD

C

AS

T

FI

R

E

AL

AR

M

M

ES

SA

G

E

BR

O

AD

C

AS

T

FI

R

E

AL

AR

M

T R

O U

BL

E

SI

G

N

AL

BR

AD

C

AS

T

R

EC

O R

D

ED

O R

L

IV

E M

AS

S

N O

TI

FI

C

AT

IO

N

M

ES

SA

G

E

SH

U

T D

O W

N P

R O

TE

C

TE

D

A

IR

-H

AN

D

LI

N G

U N

IT

(S

N

O

TE

U N

LO

C

K

IN

D

IC

AT

ED

D O

O R

S

VI

A D

O O

R C

O N

TR

O

LL

ER

S (N

O

TE

MANUAL FIRE ALARM PULL STATION

SPRINKLER WATER FLOW SWITCH - OTHER

SPRINKLER VALVE TAMPER SWITCH AND PIV

SMOKE DETECTOR - ESS ROOM

DUCT SMOKE DETECTOR

FACP TROUBLE

FACP SILENCE SWITCH (NOTES 1A, 1B, AND 1C)

MNS ACTIVATION (NOTE 2)

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/22/2018 4:02:44 PM

AP

R

IL

W

2H N

-1 8-

B-

- C

AT

C O

D E

FA001

FI

R

E

AL

AR

M

L

EG

EN

D

A N

D O

PE

R

AT

IO

N S

M

AT

R

IX

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

F

F

F F 245'

FA

C

P/ M

N S

RA

VESTIBULE

B100

LOBBY

B101

ELECT. ROOM

B102

T.E.R.

B103

DUTY STATION

B104

CORRIDOR

A110

MECHANICAL

A111

OPEN OFFICE

A109

CLASSROOM

A108

CO. CDR OFFICE

A102

HR OFFICE

A104

SUPPLY SGT OFFICE

A103

FIRST SGT OFFICE

A100

FILES/PRINTING

A105

SUPPLY STORAGE

A106

CORRIDOR

A110

CORRIDOR

A107

CPB READINESS AREA

C100

NERD SERVER ROOM

C102

UNIT STORAGE AREA

C103

COMM. STORAGE AREA

C104

NBC STORAGE AREA

C105

ARMS VAULT

C106

ARMS VAULT

D105

ARMY CYBER STORAGE- OUT

D104

JANITORS CLOSET

D103

ELECTRIC ROOM

D101

ESS ROOM

D102

MDP

LDP

S

LO

C

LOC

LOC

LO

C

FAS

CO

15 15

15 15

45 45

60 60

45 45

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/25/2018 4:18:09 PM

AP

R

IL

W

2H N

-1 8-

B-

- C

AT

C O

D E

FA101

FI

R

E

AL

AR

M

M

AS

S

N O

TI

FI

C

AT

IO

N

S

YS

TE

M

S

PL

AN

PA

R

TS

A

C

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

KEYED NOTES:

1. UNLOCK DOOR UPON FIRE ALARM ACTIVATION.

SEE FIRE ALARM AND MASS NOTIFICATION SYSTEM

MATRIX FOR CONDITIONS THAT SHALL UNLOCK

DOORS.

SHEET NOTES:

1. SEE SHEET FA001 FOR LEGEND, LABELING

SCHEME AND GENERAL NOTES.

KEY

PLAN

PART A PART B

PART

C

PART D

164 8268

SCALE: 1/8"=1'-0"

GRAPHIC SCALE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

REF.

F

F

F F

LTB

FA

C

P/ M

N S

RA

CORRIDOR

B112

BREAKROOM

B107

RECYCLED MATERIALS

STORAGE CLOSET

B109

JANITORS CLOSET

B111

MEN LATRINE/LOCKERS

B108

WOMENS LATRINE/LOCKERS

B105

SIPR KIOSK

B113 T.R.

B116

J.F.H.Q. OFFICE 2

B115

J.F.H.Q. OFFICE 1

B114

ARMS VAULT

D105

ARMY CYBER READINESS

STORAGE - IN

D106

COMM. STORAGE AREA

D107

NBC STORAGE AREA

D108

UNIT STORAGE AREA

D109

SECURE NON SENSITIVE

STORAGE

D110

CLASSROOM

D112

CORRIDOR

B112

CORRIDOR

B126

CLASSROOM STORAGE

ROOM

B121

FILES/PRINTING

B125

OP. OFFICE

B124

XO OFFICE

B120

FIRST SGT OFFICE

B119

CDR. OFFICE

B123

CLASSROOM

B118

OPEN OFFICE

B117

S

LO

C

LOC

LO

C

15 15

6060606060

60 60

MNS

ANTENNA

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/25/2018 12:12:27 PM

AP

R

IL

W

2H N

-1 8-

B-

D es ig ne r

Au th or

Ap pr ov er

C

AT

C O

D E

FA102

FI

R

E

AL

AR

M

M

AS

S

N O

TI

FI

C

AT

IO

N

S

YS

TE

M

S

PL

AN

PA

R

TS

B

D

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

C he ck er

ISSUED FOR CONSTRUCTION

KEYED NOTES:

1. UNLOCK DOOR UPON FIRE ALARM ACTIVATION.

SEE FIRE ALARM AND MASS NOTIFICATION SYSTEM

MATRIX FOR CONDITIONS THAT SHALL UNLOCK

DOORS.

SHEET NOTES:

1. SEE SHEET FA001 FOR LEGEND, LABELING

SCHEME AND GENERAL NOTES.

KEY

PLAN

PART A PART B

PART

C

PART D

164 8268

SCALE: 1/8"=1'-0"

GRAPHIC SCALE

1 1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

ELECTRICAL LEGEND

C

R T

J

B

TTB

CTB

V

20 AMP QUAD RECEPTACLE, MH 1'-6", UON OR UOI. SUBSCRIPT 'X'

(WHERE PRESENT) DENOTES THE FOLLOWING:

OS - CONTROLLED BY ROOM OCCUPANCY SENSORS VIA

RECEPTACLE-RATED SWITCHPACK. TOP OUTLET OF EACH

RECEPTACLE STRAP SHALL BE CONTROLLED; BOTTOM

OUTLET TO BE UNCONTROLLED. OUTLET SHALL BE MARKED IN

ACCORDANCE WITH N.E.C., ARTICLE 406.3(E).

20 AMP CEILING MOUNTED RECEPTACLE OUTLET

VGA CEILING OUTLET FOR CONNECTING THE USER'S

PROJECTOR

RECESSED COMBINATION FLOOR DUPLEX RECEPTACLE

(20 AMP) AND DUPLEX TELEPHONE OUTLET

JUNCTION BOX, WALL MTD. MH 1'-6" U.O.N.

MOTOR RATED SWITCH

MOTOR DISCONNECT/SAFETY SWITCH SHALL BE RATED

30/3/NF/1 UNLESS OTHERWISE INDICATED.

'30' DENOTES SWITCH AMPERE RATING;

'3' DENOTES NUMBER OF POLES;

'NF' DENOTES NON-FUSED ('F' DENOTES FUSED);

'1' DENOTES SWITCH ENCLOSURE'S RATING;

FUSE RATING SHALL BE IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS.

MOTOR STARTER, FURNISHED BY OTHER SECTIONS

BOILER EMERGENCY SHUT-OFF

FIRE-RETARDANT PLYWOOD BACKBOARD WITH NO ADDED

UREA FORMALDEHYDE. SEE SPECIFICATIONS 01 33 29

FOR FSC CERTIFICATION REQUIREMENTS.

TW T #

SPD

SYSTEM GROUND, SIZE IN ACCORDANCE WITH NEC ARTICLE 250

GROUND ROD, "TW" INDICATES TEST WELL

LIGHTNING PROTECTION ROOF CONDUCTORS. SEE DRAWINGS FOR

SIZE.

AIR TERMINAL

PANELBOARD - MH IN ACCORDANCE WITH NEC

DRY-TYPE TRANSFORMER

SURGE PROTECTIVE DEVICE

LIGHTNING PROTECTION COUNTERPOISE CONDUCTORS. SEE

DRAWINGS FOR SIZE.

LED LUMINAIRES. SEE LIGHT FIXTURE SCHEDULE, DETAILS, AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

LED LUMINAIRES WITH EMERGENCY DRIVERS OR CONNECTED TO AN

EMERGENCY LIGHTING INVERTER

WALL MOUNTED LED LUMINAIRE.

WALL MOUNTED LED LUMINAIRE WITH EMERGENCY DRIVER.

WALL MOUNTED LED LUMINAIRES.

SUSPENDED LED LUMINAIRE.

SUSPENDED LED LUMINAIRE WITH INTEGRAL EMERGENCY

DRIVER.

EXIT LIGHT, CEILING MOUNTED, SHADING INDICATES FACES.

PROVIDE DIRECTIONAL ARROWS WHEN INDICATED.

EXIT LIGHT, WALL MOUNTED, SHADING INDICATES FACES. PROVIDE

DIRECTIONAL ARROWS WHEN INDICATED. MOUNT BOTTOM OF

FIXTURE 6" ABOVE TOP OF DOOR UNLESS OTHERWISE INDICATED.

WALL SWITCH, SINGLE POLE, 20A SWITCH. WHERE SUBSCRIPT IS PRESENT,

IT DENOTES THE FOLLOWING:

3 - THREE WAY SWITCH.

4 - FOUR WAY SWITCH.

a - SINGLE LOWER CASE LETTER (EXCEPT LETTER "m") DENOTE THE

SWITCH THAT CONTROLS THE FIXTURES.

WP - WEATHERPROOF (GASKETED).

MOTOR RATED SWITCH FOR CEILING FAN.

WALL SWITCH SENSOR, LINE VOLTAGE. SUBSCRIPTS ARE DENOTED VIA

DETAILS ON SHEET EL601.

DIGITAL TIME SWITCH, LINE VOLTAGE. SEE DETAIL ON SHEET EL601.

LOW VOLTAGE, MULTI-BUTTON SWITCH CONNECTED TO ROOM CONTROLLER

OR LIGHTING CONTROL PANEL. SUBSCRIPTS ARE DENOTED VIA DETAILS ON

SHEET EL601.

OCCUPANCY SENSOR. WALL MOUNTED, DUAL TECHNOLOGY (ULTRASONIC

AND PIR) SENSOR UOI. SUBSCRIPT "P" INDICATES ONLY PIR.

OCCUPANCY SENSOR. CEILING MOUNTED, ULTRASONIC SENSOR UOI.

DAYLIGHT SENSOR.

EXTERIOR PHOTOCELL.

LIGHTING CONTROL PANEL (LCP).

EMERGENCY LIGHTING INVERTER.

LOWER CASE DENOTES THE SWITCH THAT CONTROLS FIXTURE

LUMINAIRE TYPE DESIGNATION

SYMBOL DENOTES GENERAL TYPE OF LUMINAIRE

UNSWITCHED NIGHT LIGHT (ON 24

HOURS)

a A2

NT

T

LCP

OS

DS

LVX

ELI

PC

LIGHTING AND LIGHTING CONTROLS SYSTEM LEGEND

OSX

fan

20 AMP QUAD RECEPTACLE, MOUNTED IN FLOOR BOX.

GENERAL NOTES

1. SEE PLATE E-002 FOR ABBREVIATIONS AND TYPICAL MOUNTING HEIGHT

DIAGRAM.

2. MOUNTING HEIGHT, UNLESS OTHERWISE NOTED, IS TO CENTER LINE OF

EQUIPMENT.

3. MOUNT OUTLET BOXES SO THAT NONE OCCUR BACK TO BACK IN WALLS.

4. MECHANICAL EQUIPMENT IS SHOWN IN APPROXIMATE LOCATIONS. FOR

EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND PIPING, SEE MECHANICAL

DRAWINGS. PROVIDE DISCONNECT SWITCHES AS REQUIRED BY THE NATIONAL

ELECTRICAL CODE EVEN IF NOT INDICATED ON THE ELECTRICAL DRAWINGS.

5. COORDINATE THE LOCATIONS AND MOUNTING HEIGHTS OF LIGHTING

FIXTURES IN MECHANICAL AND ELECTRICAL ROOMS WITH THE FINAL LOCATIONS

OF PIPES, DUCTS AND OTHER EQUIPMENT FOR BEST ARRANGEMENT. FIXTURES

SHALL BE EASILY ACCESSIBLE FOR RELAMPING.

6. CONDUCTOR AND CONDUIT SIZES ARE BASED ON COPPER CONDUCTORS

WITH THWN INSULATION IN EMT CONDUIT. CIRCUIT BREAKERS, TERMINALS, ETC.

SHALL BE RATED AND MARKED FOR 75 DEGREES MINIMUM. THE CONTRACTOR

SHALL ADJUST CONDUIT SIZES BASED ON ACTUAL TYPE OF CONDUCTORS AND

CONDUIT INSTALLED.

7. CIRCUIT NUMBERS ARE SHOWN ADJACENT TO ELECTRICAL DEVICES. WIRING

SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS

AND/OR REQUIREMENTS.

8. ALL WIRING SHALL BE CONCEALED UNLESS INDICATED OTHERWISE.

CONDUITS SHALL NOT BE RUN IN ANY UL RATED SLAB.

9. REVISE PANELBOARD SCHEDULES ON AS-BUILT-DRAWING AND PANEL

DIRECTORIES TO REFLECT FINAL INSTALLATION CONDITIONS.

10. SEAL PENETRATIONS THROUGH ROOFS, CEILINGS, FLOORS, WALLS AND

FIRE WALLS TO MAINTAIN THE INTEGRITY OF THE AIR BARRIER, FIRE AND

ACOUSTIC RATINGS OF THE ROOF, CEILINGS, WALLS AND FLOORS.

11. COMPONENTS WHICH CONSTITUTE AN ELECTRICAL SYSTEM SHALL BE FULLY

COMPATIBLE WITH ONE ANOTHER AND SHALL BE APPROVED BY THE VARIOUS

MANUFACTURERS FOR USE WITH ALL OTHER COMPONENTS WITHIN THE

SYSTEM. (ONE EXAMPLE OF AN ELECTRICAL SYSTEM IS THE BUILDING LIGHTING

SYSTEM COMPRISED OF FIXTURES, LAMPS, SWITCHES, BALLASTS, OCCUPANCY

SENSORS AND DIMMING EQUIPMENT).

12. LOCATE ALL RACEWAYS TO AVOID INTERFERENCE WITH DUCTS, PIPES,

MECHANICAL EQUIPMENT, WITH REMOVAL OF CEILING TILES, OR WITH ACCESS

TO EQUIPMENT WHICH REQUIRES PERIODIC ADJUSTMENT OR MAINTENANCE.

13. PROVIDE NAMEPLATES ON THE EXTERIOR OF ALL ELECTRICAL PANELS AND

ENCLOSURES AS FOLLOWS: DEVICE ID, DEVICE RATING, POWER SOURCE, ARC

FAULT DATA. ARC-FAULT DATA SHALL MEET 2015 NFPA 70E REQUIREMENTS.

14. FOR DISCONNECT SWITCHES AND MOTOR STARTERS THE TOP LINE SHALL

BE THE NAME/DESIGNATION OF THE EQUIPMENT BEING FED BY THE

SWITCH/STARTER.

15. PROVIDE SEPARATE NEUTRALS FOR EACH CIRCUIT UTILIZING A NEUTRAL

CONDUCTOR. MULTI-WIRE CIRCUITS ARE NOT ALLOWED.

16. PROVIDE EQUIVALENT CONDUIT PATHWAYS WHERE CABLE TRAY IS

INTERRUPTED BY NONACCESSIBLE CEILINGS.

17. THE INTERRUPTING RATING OF THE PANELBOARDS AND ELECTRICAL

EQUIPMENT SHALL BE INCREASED TO THE NEXT AVAILABLE RATING WHERE

THERE IS NOT A RATING THAT IS EQUAL TO THE EQUIPMENT'S LISTED SHORT

CIRCUIT RATING.

18. PROVIDE GROUNDING CONDUCTORS IN ALL CONDUITS.

19. RACEWAYS CROSSING STRUCTURAL EXPANSION JOINTS OR SEISMIC JOINTS

SHALL BE PROVIDED WITH EXPANSION FITTINGS TO COMPENSATE FOR THE

BUILDING EXPANSION AND CONTRACTION AND TO PROVIDE FOR CONTINUITY OF

GROUNDING. EXPANSION FITTINGS SHALL HAVE AN INTEGRAL BONDING

JUMPER. ONLY FITTING LISTED AS EXPANSION TYPES WILL BE CONSIDERED

SUITABLE.

20. RECEPTACLES THAT HAVE GFI PROTECTION ARE TO BE WIRED SUCH THAT

THE LOSS OF POWER ON ONE RECEPTACLE DOES NOT AFFECT DOWNSTREAM

RECEPTACLES.

20 AMP DUPLEX RECEPTACLE, SUBSCRIPT 'X' (WHERE PRESENT)

DENOTES THE FOLLOWING:

WP - DENOTES WEATHER PROOF WHILE-IN-USE HOUSING.

GFCI - DENOTES GROUND FAULT CIRCUIT INTERRUPTER (GFCI)

RECEPTACLE

GC - DENOTES ABOVE COUNTERTOP GFCI RECEPTACLE.

EWC - DENOTES ELECTRIC WATER COOLER.

COORDINATE MOUNTING WITH EQUIPMENT PROVIDED.

TV - DENOTES TELEVISION. COORDINATE MOUNTING WITH CATV

OUTLET.

OS - CONTROLLED BY ROOM OCCUPANCY SENSORS VIA

RECEPTACLE-RATED SWITCHPACK. TOP OUTLET OF EACH

DUPLEX RECEPTACLE SHALL BE CONTROLLED; BOTTOM

OUTLET TO BE UNCONTROLLED. OUTLET SHALL BE MARKED IN

ACCORDANCE WITH N.E.C., ARTICLE 406.3(E).

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXMPB\Documents\FY17PN85794_MEP_R18_K6ENXMPB.rvt

6/28/2018 12:00:55 PM

AP

R

IL

W

2H N

-1 8-

B-

SJ

A

C

AT

C O

D E

E-001

EL

EC

TR

IC

AL

L

EG

EN

D

G

EN

ER

AL

N O

TE

S

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

J

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/25/2018 4:40:40 PM

AP

R

IL

W

2H N

-1 8-

B-

SJ

A

C

AT

C O

D E

EG101

LI

G

H

TN

IN

G

P R

O

TE

C

TI

O N

P

LA

N

PA

R

TS

A

C

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

KEYED NOTES:

1. CLASS 1 MAIN CONDUCTOR SIZED 57,400

CIRCULAR MILS.

SHEET NOTES:

1. SEE SHEET E-001 FOR LEGEND, AND GENERAL

NOTES.

2. THE LIGHTNING PROTECTION INSTALLER SHALL

COORDINATE ROOF PENETRATIONS WITH THE ROOF

INSTALLER. PENETRATIONS SHALL COMPLY WITH

THE ROOF MANUFACTURER'S RECOMMENDATIONS.

SEALING AND FLASHING OF PENETRATIONS SHALL

BE BY THE ROOF INSTALLER.

3. VARIATIONS IN AIR TERMINAL SPACING SHALL BE

ALLOWED WHERE REQUIRED TO ACCOMMODATE

SITE CONDITIONS, EXCEPT NO SPACING BETWEEN

AIR TERMINALS SHALL EXCEED 20 FEET AND NO

PERIMETER AIR TERMINALS SHALL BE MORE THAN

24 INCHES FROM ROOF EDGE.

4. ROOF MOUNTED MECHANICAL VENT PIPING AND

EQUIPMENT SHALL BE PROTECTED WITH AIR

TERMINALS INTERCONNECTED WITH THE LIGHTNING

PROTECTION SYSTEM PER THE DETAIL ON EG501.

SEE MECHANICAL DRAWINGS FOR LOCATIONS OF

MECHANICAL VENT PIPING AND EQUIPMENT.

5. SEE STRUCTURAL DRAWINGS FOR EXACT

LOCATIONS OF COLUMNS.

6. METAL PARTS WITHIN 6 FEET OF THE LIGHTNING

PROTECTION SYSTEM SHALL BE BONDED TO THE

LIGHTNING PROTECTION SYSTEM. METAL PARTS

FURTHER THAN 6 FEET SHALL ALSO BE BONDED IF

THEY ARE WITHIN 6 FEET OF A METAL PART THAT IS

BONDED TO THE LIGHTNING PROTECTION SYSTEM.

7. LIGHTNING PROTECTION CONDUCTORS PASSING

THROUGH CONCRETE FOUNDATION, SLABS OR PADS

SHALL BE ROUTED IN CONDUIT.

8. TEE SPLICES SHALL BE EXOTHERMIC WELDED

BELOW GRADE.

9. INSTALLED LIGHTNING PROTECTION SYSTEM

SHALL BE FIELD INSPECTED BY CONTRACTOR-

PROVIDED INDEPENDENT TESTING AGENCY AND

FURNISHED WITH A UL MASTER LABEL FOR

LIGHTNING PROTECTION SYSTEM.

10. ADDITIONAL REQUIREMENTS ARE LOCATED IN

SPEC 26 41 01.00 10, LIGHTNING PROTECTION

SYSTEM.

11. MAIN CONDUCTORS SHALL BE CLASS 1

MATERIALS IAW NFPA 780.

KEY

PLAN

PART A PART B

PART

C

PART D

SCALE: 3/32"=1'-0"

816 16

GRAPHIC SCALE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 8

TYP.

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/25/2018 4:40:49 PM

AP

R

IL

W

2H N

-1 8-

B-

SJ

A

C

AT

C O

D E

EG102

LI

G

H

TN

IN

G

P R

O

TE

C

TI

O N

P

LA

N

PA

R

TS

B

D

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

KEYED NOTES:

1. CLASS 1 MAIN CONDUCTOR SIZED 57,400

CIRCULAR MILS.

SHEET NOTES:

1. SEE SHEET E-001 FOR LEGEND, AND GENERAL

NOTES.

2. THE LIGHTNING PROTECTION INSTALLER SHALL

COORDINATE ROOF PENETRATIONS WITH THE ROOF

INSTALLER. PENETRATIONS SHALL COMPLY WITH

THE ROOF MANUFACTURER'S RECOMMENDATIONS.

SEALING AND FLASHING OF PENETRATIONS SHALL

BE BY THE ROOF INSTALLER.

3. VARIATIONS IN AIR TERMINAL SPACING SHALL BE

ALLOWED WHERE REQUIRED TO ACCOMMODATE

SITE CONDITIONS, EXCEPT NO SPACING BETWEEN

AIR TERMINALS SHALL EXCEED 20 FEET AND NO

PERIMETER AIR TERMINALS SHALL BE MORE THAN

24 INCHES FROM ROOF EDGE.

4. ROOF MOUNTED MECHANICAL VENT PIPING AND

EQUIPMENT SHALL BE PROTECTED WITH AIR

TERMINALS INTERCONNECTED WITH THE LIGHTNING

PROTECTION SYSTEM PER THE DETAIL ON EG501.

SEE MECHANICAL DRAWINGS FOR LOCATIONS OF

MECHANICAL VENT PIPING AND EQUIPMENT.

5. SEE STRUCTURAL DRAWINGS FOR EXACT

LOCATIONS OF COLUMNS.

6. METAL PARTS WITHIN 6 FEET OF THE LIGHTNING

PROTECTION SYSTEM SHALL BE BONDED TO THE

LIGHTNING PROTECTION SYSTEM. METAL PARTS

FURTHER THAN 6 FEET SHALL ALSO BE BONDED IF

THEY ARE WITHIN 6 FEET OF A METAL PART THAT IS

BONDED TO THE LIGHTNING PROTECTION SYSTEM.

7. LIGHTNING PROTECTION CONDUCTORS PASSING

THROUGH CONCRETE FOUNDATION, SLABS OR PADS

SHALL BE ROUTED IN CONDUIT.

8. TEE SPLICES SHALL BE EXOTHERMIC WELDED

BELOW GRADE.

9. INSTALLED LIGHTNING PROTECTION SYSTEM

SHALL BE FIELD INSPECTED BY CONTRACTOR-

PROVIDED INDEPENDENT TESTING AGENCY AND

FURNISHED WITH A UL MASTER LABEL FOR

LIGHTNING PROTECTION SYSTEM.

10. ADDITIONAL REQUIREMENTS ARE LOCATED IN

SPEC 26 41 01.00 10, LIGHTNING PROTECTION

SYSTEM.

11. MAIN CONDUCTORS SHALL BE CLASS 1

MATERIALS IAW NFPA 780.

KEY

PLAN

PART A PART B

PART

C

PART D

SCALE: 3/32"=1'-0"

816 16

GRAPHIC SCALE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 8

TYP.

SBB

PBB

PGB

PM

G

B

2 2

T.E.R.

B103

TW

TW TW

ELECT. ROOM

B102

MECHANICAL

A111

OH

ELECTRIC

ROOM

D101

NERD

SERVER

ROOM

C102

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/25/2018 4:10:04 PM

AP

R

IL

W

2H N

-1 8-

B-

SJ

A

C

AT

C O

D E

EG103

G R

O U

N D

IN

G

P

LA

N

PA

R

TS

A

C

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

KEYED NOTES:

1. GROUND RING LOOP CONDUCTOR SIZED IAW

N.E.C. ARTICLE 250 AND NFPA 780.

SHEET NOTES:

1. SEE SHEET E-001 FOR LEGEND, LABELING

SCHEME AND GENERAL NOTES.

KEY

PLAN

PART A PART B

PART

C

PART D

SCALE: 3/32"=1'-0"

816 16

GRAPHIC SCALE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 8

TYP. 1

SBB

TW

TW

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/25/2018 4:10:27 PM

AP

R

IL

W

2H N

-1 8-

B-

SJ

A

C

AT

C O

D E

EG104

G R

O U

N D

IN

G

P

LA

N

PA

R

TS

B

D

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

KEYED NOTES:

SHEET NOTES:

1. SEE SHEET E-001 FOR LEGEND, LABELING

SCHEME AND GENERAL NOTES.

KEY

PLAN

PART A PART B

PART

C

PART D

SCALE: 3/32"=1'-0"

816 16

GRAPHIC SCALE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

1 8

1. GROUND RING LOOP CONDUCTOR SIZED IAW

N.E.C. ARTICLE 250 AND NFPA 780.

TYP.

PRIMARY BONDING BUSBAR (PBB)

2-HOLE COMPRESSION

CRIMP GROUNDING LUG

SECONDARY BONDING BUSBAR (SBB)

NOTES: (TELECOMMUNICATION GROUND BUS DETAILS)

1.FOR ELECTRICAL NOTES, ABBREVIATIONS, AND SYMBOLS REFER

TO DRAWING E-001.

2. TMGB BUSBARS SHALL BE A MINIMUM 1/4" THICK, 4" WIDE AND

20" LONG. TGB BUSBARS SHALL BE A MINIMUM 1/4" THICK, 2" WIDE

AND 20" LONG. BUSBARS SHALL BE INSULATED FROM THEIR

SUPPORTS BY A MINIMUM OF 2”. THE COPPER BUSBARS SHALL BE

UL LISTED AND PRE-DRILLED WITH STANDARD NEMA BOLT HOLE

SIZING AND SPACING FOR THE TYPE AND SIZE OF CONDUCTOR

BEING USED. THE BUSBARS SHALL BE CLEANED PRIOR TO

FASTENING OF CONDUCTORS AND AN ANTI-OXIDANT SHOULD BE

APPLIED TO THE CONTACT AREA TO CONTROL CORROSION AND

REDUCE CONTACT RESISTANCE. THE BUSBARS SHALL BE

MOUNTED AT 18 INCH ABOVE FINISHED FLOOR UNLESS

OTHERWISE INDICATED.

3. TELECOMMUNICATIONS BONDING CONDUCTORS SHALL BE SIZED

IN ACCORDANCE TO TIA-607-B, 6.3.2. SIZING THE

TELECOMMUNICATIONS BONDING BACKBONE (TBB), TABLE 1 AND

6.3.3. SIZING THE BONDING CONDUCTOR FOR

TELECOMMUNICATIONS (BCT) WITH A MINIMUM OF 6 AWG.

4. ALL GROUNDING CONDUCTORS ARE NOT SHOWN. SEE

TELECOMMUNICATIONS GROUNDING RISER DIAGRAM AND

SPECIFICATIONS FOR ADDITIONAL GROUNDING CONDUCTORS AND

REQUIREMENTS.

COPPER GROUNDING

BUSBAR

GROUNDING LUG

MOUNTING HOLES

STANDOFF

MOUNTING

BRACKET

INSULATOR

2-HOLE COMPRESSION

CRIMP GROUNDING LUG

COPPER GROUNDING

BUSBAR

GROUNDING LUG

MOUNTING HOLES

STANDOFF

MOUNTING

BRACKET

INSULATOR

TELECOMMUNICATION GROUND BUS DETAILS

NOT TO SCALE

COPPER GROUNDING

BUSBAR

GROUNDING LUG

MOUNTING HOLES

STANDOFF

MOUNTING

BRACKET

INSULATOR

GROUNDING

LUG

POWER MAIN GROUND BUS (PMGB)

COPPER GROUNDING

BUSBAR

GROUNDING LUG

MOUNTING HOLES

STANDOFF

MOUNTING

BRACKET

INSULATOR

GROUNDING

LUG

POWER GROUND BUS (PGB)

NOTES:

1. FOR ELECTRICAL NOTES, ABBREVIATIONS, AND SYMBOLS REFER

TO DRAWING E-001.

2. GROUNDING BUSBARS SHALL BE A MINIMUM 1/4" THICK, (2" WIDE -

TGB) AND (4" WIDE - TMGB) WITH LENGTH AS REQUIRED AND SHALL

BE INSULATED FROM ITS SUPPORTS BY A MINIMUM OF 2”. THE

COPPER BUSBARS SHALL BE A PRE-DRILLED WITH STANDARD NEMA

BOLT HOLE SIZING AND SPACING FOR THE TYPE AND SIZE OF

CONDUCTOR BEING USED. THE BUSBARS SHALL BE CLEANED PRIOR

TO FASTENING OF CONDUCTORS AND AN ANTI-OXIDANT SHOULD BE

APPLIED TO THE CONTACT AREA TO CONTROL CORROSION AND

REDUCE CONTACT RESISTANCE. THE BUSBARS SHALL BE MOUNTED

AT 18 INCH ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED.

3. POWER BONDING CONDUCTORS SHALL BE SIZED IN ACCORDANCE

N.E.C. ARTICLE 250 WITH A MINIMUM CONDUCTOR SIZE OF 6 AWG.

4. ALL GROUNDING CONDUCTORS ARE NOT SHOWN. SEE PLANS AND

SPECIFICATIONS FOR ADDITIONAL GROUNDING CONDUCTORS OR

REQUIREMENTS.

COPPER GROUNDING

BUSBAR

GROUNDING LUG

MOUNTING HOLES

STANDOFF

MOUNTING

BRACKET

INSULATOR

GROUNDING

LUG

CABLE TV SYSTEM GROUND BUS (CGB)

ELECTRICAL POWER GROUND BUS DETAILS

NOT TO SCALE

PROVIDE REINFORCED CONCRETE

GROUND INSPECTION WELL WITH CAST

IRON LID MARKED "GROUND". MOUNT

WELL FLUSH WITH FINISHED GRADE.

COPPER CLAD GROUND ROD. TOP OF

ROD SHALL BE NOT LESS THAN 18"

BELOW GRADE AND A MINIMUM OF 24"

AWAY FROM FOOTINGS OR

FOUNDATION WALLS.

#1/0 AWG GROUND CONNECTION

TO STRUCTURE

#1/0 AWG COUNTERPOISE LOOP

MECHANICAL CLAMPING

GROUND ROD TEST WELL DETAIL

NOT TO SCALE

GROUND CONNECTION TO

STRUCTURE

BARE STRANDED COPPER

CABLE

GROUND

COUNTERPOISE &

LEAD CONDUCTORS

EXOTHERMICLY

CONNECT CABLES

TO GROUND ROD

GROUND ROD

FINISHED

GRADE

GROUND ROD CONNECTION DETAIL

NOT TO SCALE

NOTES:

1. GROUNDING SHALL BE IN ACCORDANCE WITH N.E.C. ARTICLE 250. VARIATIONS TO GROUNDING

SHOWN SHALL BE APPROVED BY THE CONTRACTING OFFICER'S REPRESENTATIVE.

2. CONDUCTORS SHALL BE SIZED BASED ON THE REQUIREMENTS OF N.E.C. ARTICLE 250.

3. LIGHTNING PROTECTION SYSTEM COUNTERPOISE CONDUCTOR SIZE SHALL BE IN ACCORDANCE

WITH NFPA 780 AND UL 96.

N

GPMGB

SERVICE

ENTRANCE

EQUIPMENT

ELEC ROOM

STRUCTURAL

STEEL

FOOTING

REBAR

METALLIC

WATER PIPE

(WHERE

APPLICABLE)

LIGHTNING

PROTECTION

SYSTEM

COUNTERPOISE

NOTE 3

GROUND

ROD

ELEC ROOM

TMGB

T.E.R.

GROUNDING ELECTRODE SYSTEM DETAIL

NOT TO SCALE

KEYED NOTES:

1. #6 AWG COPPER BONDING JUMPER.

2. #4 AWG COPPER BONDING JUMPER.

3. SIZED IN ACCORDANCE WITH N.E.C.

ARTICLE 250.66.

4. SIZED SAME AS COUNTERPOISE

CONDUCTOR. CONDUCTORS SIZED IAW

NFPA 780 AND UL 96.

43121

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSJA\Documents\FY17PN85794_MEP_R18_K6ENXSJA.rvt

6/25/2018 5:04:21 PM

AP

R

IL

W

2H N

-1 8-

B-

- C

AT

C O

D E

EG502

M

IS

C

EL

LA

N

EO

U

S G

R O

U N

D

IN

G D

ET

AI

LS

SA

VA

N N

AH

D

IS

TR

IC

T

SA

VA

N N

AH

, G

EO

R

G

IA

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AR

C

YB

ER

C O

M

PA

N Y

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

PN

ISSUED FOR CONSTRUCTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

N

OS

OS

OS

DS

OS

DS

OS

OS OS

OS OS

A2HA2H

A2HA2H

A2HA2H

A2HA2H

A2L A2L A2LE A2L A2LE

A2LE L3

A2L

A2H A2HE A2H A2H

A2H A2H A2H A2H

A2H

A2H A2HE A2H

A2H A2H A2H A2H

A2LE A2L A2L A2LE

A2H

A2L A2L

A2LE

A2L

L3

L3

L3

L3

L3

A2L

A2L

A2HA2H

A2HA2H

A2HA2H

A2HA2HE

A2HA2H

A2L

A2LA2L

A2L

L6E

L6

L6

L6

L6

L6

L6

L6

L6

L6E

R1H R1HE

R1H R1H

A2L

A2LE

A2L

A2LE

L8L8L8F1H F1H F1H F1H F1H F1H

F1H F1HE F1H F1H F1HE F1H

F1H F1H F1H F1H F1H F1H

F1H F1H F1H F1HE F1H F1H

STORAGE CLOSET

A101

FIRST SGT OFFICE

A100

CO. CDR OFFICE

A102

CLASSROOM

A108

OPEN OFFICE

A109

MECHANICAL

A111

ELECT. ROOM

B102

SU

PP

LY

S

G T

O

FF

IC

E

A1

FI

LE

S/

PR

IN

TI

N G

A1

T.E.R.

B103

DUTY STATION

B104

SU

PP

LY

S

TO

R

AG

E

A1

NERD SERVER ROOM

C102

UNIT STORAGE AREA

C103

NBC STORAGE AREA

C105

ARMS VAULT

C106

ARMS VAULT

D105

C

PB

R

EA

D

IN

ES

S

AR

EA

C

F1L F1L

F1LE F1L

MH=10'-0" AFF (F1L)

MH=9'-0" AFF

(TYP, TYPE F1H)

S1HME

S1HM

S1HME

S1HME

S1LM S1LME S1LM

S1LME

S1LM S1LW

S1LME S1LM S1LM

F1LF1L F1LE F1L F1L

F1LF1L F1L F1L F1L

MH=9'-0" AFF

MH=9'-0" AFF

(LIGHTS AND SENSORS)

COMM. STORAGE AREA

C104

R4H

R4H

F1L

F1L

WR1

WR1E

WR1

WR1

WR1

WR1

WR1

WR1 WR1

WR1

WR1

WR1F1L

F1L

S1HM

S1HM

S1HMS1LM

S1HM S1HM S1HME S1HM S1HM

S1HM S1HM S1HM S1HME S1HM S1HM

S1LW

S1LW S1LW

S1HW S1HW S1HW S1HW

S1HW S1HW S1HW S1HW

CENTER

OVER CAGE

CENTER

OVER CAGE

CENTER

OVER CAGE

CENTER

OVER CAGE

TYPE S1L LUMINAIRES MH = 11'-0" AFF

(MEASURED TO BOTTOM OF LUMINAIRE)

S1HME

A2L F1 L

F1 L

F1 L

F1 L

A2L

MH=8'-4" AFF

MH=

8'-4" AFF

MH=9'-6" AFF

VESTIBULE

B100

LV

LV

LV

LV

LV

LV

SLVDav

OS

O S

T

CORRIDOR

A107

CORRIDOR

A110

LOBBY

B101

LV2

LV2LV2

T LV2 LV2

LV

CKT HAB- 1 CKT HAB- 1 CKT HAB- 1

CKT HAB- 1

C

KT

H

AB

-1 C

KT

H

AB

-1

C

KT

H

AB

-1CKT HAB- 2

CKT HAB- 3

CKT HAB- 2

CKT HAB- 2

CKT HAB- 8

CKT HAB- 2 CKT HAB- 4

CKT HAB- 5

CKT HAB- 3

CKT HAB- 3

CKT HAB- 3

CKT HAB- 4

C

KT

H C

D -6

C

KT

H C

D -6

C

KT

H C

D -6

CKT HCD- 7 CKT HCD- 9CKT HCD- 9 CKT HCD- 9 CKT HCD- 9

CKT HCD- 6

CKT HAB- 14

CKT HCD- 22

W2EP

W2EP

LV

LV

C

KT

H

AB

-1

W 2P

S

LVD5d

O S

12 12 12

1 1

2 5 5 1 1

4 3

W1

CKT HAB- 14

MH=1'-0" BFC

MH=9'-6" AFF

S1LM

CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3 CKT HCD- 3

CKT HCD- 5 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5

CKT HCD- 1 CKT HCD- 1 CKT HCD- 1 CKT HCD- 1

CKT HCD- 1 CKT HCD- 1 CKT HCD- 1 CKT HCD- 1

CKT HCD- 5

CKT HCD- 5

CKT HCD- 3 CKT HCD- 5 CKT HCD- 5 CKT HCD- 5

CKT HCD- 3

CKT HCD- 3 CKT HCD- 1CKT HCD- 1

CKT HCD- 1CKT HCD- 1

H R

O

FF

IC

E

A1

L86R

L86

L86R

L8L8 L8 L8

L8L8…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.