15R12Ph2vol2.pdf

PDF 26 MB Posted

Attached to
Replace Pierce Terrace Elementary School Federal contract opportunity
Solicitation number
W912HN-15-R-0012
Issued by
Department of the Army Corps of Engineers Engineering District Savannah

About this file

W912HN-15-R-0012 AMD2 SPECS VOL2

View the file

Other files for this federal contract opportunity

Other files attached to Replace Pierce Terrace Elementary School, newest first.
File Type Posted
amd_6.pdf PDF
amd5.pdf PDF
15R12Ph2vol1.pdf PDF
W912HN-15-R-0012_AMD4.PDF PDF
15R12Ph2vol2.pdf PDF
Amd4.pdf PDF
15R12Ph2vol1.pdf PDF
amd3.pdf PDF
15R12Ph2vol1.pdf PDF
W912HN-15-R-0012_AMD2.PDF PDF
15R12Ph2vol1.pdf PDF
W912HN-15-R-0012_FIO_AMD2.pdf PDF
AMD2.pdf PDF
amd1.pdf PDF
W912HN-15-R-0012_Solicitation.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(Revised by Amendment 0002)

Fort Jackson, South Carolina

Solicitation Number

W912HN-15-R-0012

Replace Pierce Terrace Elementary School Volume 2 of 2: Appendices

PN AM00035

March 2016

*2 PHASE TWO OF TWO PHASE

DESIGN/BUILD SUBMITTAL PROCEDURE

This acquisition is being solicited on an unrestricted basis as full and open competition, but contains a HubZone Price Evaluation Preference

U.S. ARMY ENGINEER DISTRICT, SAVANNAH

CORPS OF ENGINEERS

100 WEST OGLETHORPE AVENUE

SAVANNAH, GEORGIA 31401-3640

US Army Corps of Engineers Savannah District

Table of Contents - Page 1

PROJECT TABLE OF CONTENTS

SPECIFICATIONS

01 11 00 SUMMARY OF WORK

01 14 00 WORK RESTRICTIONS

01 32 01.00 10 PROJECT SCHEDULE

01 33 00 SUBMITTAL PROCEDURES

01 33 16 DESIGN AFTER AWARD

01 33 29.10 LEED(TM) DOCUMENTATION

01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS

01 42 00 SOURCES FOR REFERENCE PUBLICATIONS

01 45 00.00 10 QUALITY CONTROL

01 45 00.10 10 QUALITY CONTROL SYSTEM (QCS)

01 45 35 SPECIAL INSPECTION FOR SEISMIC-RESISTING SYSTEMS

01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS

01 57 19.11 INDOOR AIR QUALITY (IAQ) MANAGEMENT

01 57 20.00 10 ENVIRONMENTAL PROTECTION

01 62 35.10 RECYCLED/RECOVERED/BIOBASED MATERIALS

01 74 19.10 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT

01 78 00 CLOSEOUT SUBMITTALS

01 83 16.10 EXTERIOR ENCLOSURE PERFORMANCE REQUIREMENTS

02 41 00 DEMOLITION

APPENDICES

Appendix A School Program Requirements Appendix B Not Used Appendix C Room Data Sheets Appendix D Acoustical Requirements Appendix E Sustainable Design Information Appendix F Utilities Points of Contact DPW Utility Rates Appendix G Subsurface Exploration Report Finding of No Significant Impact Wetlands Preliminary Jurisdictional Determination Appendix H AHERA Survey Asbestos Survey Reports Appendix I Fire Protection: Fire Flow Tests Appendix J Site Communications Services Connection Location Appendix K Specification 1140 00 Food Service Equipment Appendix L Life Cycle Cost Analysis Fuel Cost Information Appendix M Gymnasium and Play Court Floor Graphics Appendix N Fort Jackson Installation Design Guide Appendix O Context Photos Key Context Photo Thumbnails Appendix P Erosion Control Appendix Q Geothermal Test Loop Installation and Thermal Conductivity

Test Appendix R Fort Jackson Stormwater Runoff Requirements Appendix S DDESS Antiterrorism, Security & Safety Office Construction

Guide DoDEA Security Engineering Design/ Planning Baseline DDESS Lockdown Shelter-In-Place Requirements

Table of Contents - Page 2

Appendix T Supplementary Instructions to the Savannah District Design Manual for Military Construction

Appendix U DoDEA Approved Software Appendix V Environmental Condition of Property Report

-- End of Project Table of Contents --

APPENDIX A

SCHOOL PROGRAM REQUIREMENTS

JACOBS 1 of 3

Pierce Terrace Elementary School

Program Comparison Corrected DB RFP - 8/11/2015

Space UNIT SF UNITS Sub Total Program SF Comments

Neighborhood 1 1 Learning Studio 900 1 900 900 2 Learning Studio 900 1 900 900 3 Learning Studio - PSCD 900 1 900 900 4 Learning Studio 900 1 900 900 Learning Hub Allowance 350 4 1,400 2,168 Concept SF includes circulation Group Learning Allowance 50 4 200 200 One-to-One Allowance 25 4 100 124

Staff Collaboration 875 884 Staff collaboration spaces combined into one room

SC Workspace & Personal Storage 100 5 500 SC Kitchenette Allowance 10 5 50 SC Collaboration Area Allowance 30 5 150 SC Shared Storage Allowance 35 5 175

Neighborhood 2 5 Learning Studio 900 1 900 900 6 Learning Studio 900 1 900 900 7 Learning Studio 900 1 900 900 8 Learning Studio 900 1 900 900 Learning Hub Allowance 350 4 1,400 2,704 Concept SF includes circulation Group Learning Allowance 50 4 200 241 One-to-One Allowance 25 4 100 129

Staff Collaboration 1,347.5 1,400 Staff collaboration spaces combined into one room

SC Workspace & Personal Storage 100 8 800 SC Kitchenette Allowance 10 8 80 SC Collaboration Area Allowance 30 8 240

SC Shared Storage Allowance 35 6.5 227.5 Storage not included for PE, Art, Music

Neighborhood 3 9 Learning Studio 900 1 900 900 10 Learning Studio 900 1 900 900 11 Learning Studio 900 1 900 900 12 Learning Studio 900 1 900 900

Learning Hub Allowance 350 4 1,400 2,738 Concept SF includes circulation Group Learning Allowance 50 4 200 241 One-to-One Allowance 25 4 100 122

Staff Collaboration 1,190 1,226 Staff collaboration spaces combined into one room

SC Workspace & Personal Storage 100 7 700 SC Kitchenette Allowance 10 7 70 SC Collaboration Area Allowance 30 7 210

SC Shared Storage Allowance 35 6 210 Storage not included for itinerant from IC

Neighborhood 4 13 Learning Studio 900 1 900 900 14 Learning Studio 900 1 900 900 15 Learning Studio 900 1 900 900 16 Learning Studio 900 1 900 900 17 Learning Studio 900 1 900 900

Learning Hub Allowance 350 5 1,750 2,396 Concept SF includes circulation Group Learning Allowance 50 5 250 250 One to one 25 5 125 127

1,225 1,225 Staff collaboration spaces combined into one room

SC Workspace & Personal Storage 100 7 700 SC Kitchenette Allowance 10 7 70 SC Collaboration Area Allowance 30 7 210 SC Shared Storage Allowance 35 7 245

Learning Impaired - Mild/Moderate 400 1 400 404 Reading Lab 400 1 400 417

Learning Impaired Moderate/Severe 1 SC Workspace & Personal Storage 100 0 0 1 SC Kitchenette Allowance 10 0 0 1 SC Collaboration Area Allowance 30 0 0 1 SC Shared Storage Allowance 35 0 0 SC spaces combined with SC4 1 Student Instruction Area 1000 1 1000 1,222 Instruct/Kitchen 1 Kitchen 275 1 275 1 HC Restroom 75 1 75 58 1 Changing & Shower Area 75 1 75 92

Subtotal 1,425 1,372

Corrected DB RFP Deliverable Plan

Program for Design SF

JACOBS 2 of 3

Program Comparison Corrected DB RFP - 8/11/2015

Space UNIT SF UNITS Sub Total Program SF Comments Corrected DB RFP Deliverable Plan

Program for Design SF

Exploratory Learning Spaces 1 Computing Center 1200 1 1,200 1,203

Art Room SC Workspace & Personal Storage 100 0 0 Added to Neighborhood SC SC Kitchenette Allowance 10 0 0 SC Collaboration Area Allowance 30 0 0 Art Classroom 1000 1 1000 1,004 Kiln 100 1 100 125 Art Workroom/Storage 200 1 200 201 Subtotal 1,300 1,330

Music Suite SC Workspace & Personal Storage 100 0 0 Added to Neighborhood SC SC Kitchenette Allowance 10 0 0 SC Collaboration Area Allowance 30 0 0 Music Room 1000 1 1000 1,003 Music StoragevRoom 250 1 250 251 Subtotal 1,250 1,254

OT/PT

1 Therapy Area 800 1 800 802 1 Workspace/Storage/Observation 400 1 400 400

Subtotal 1,200 1,202

Commons 1 Commons 1284 1 1284 1 Recycle Area 150 1 150

Subtotal 1,434 3,095 Concept SF includes circulation and allocation from reduced PE

Multipurpose Room 1 Multipurpose Room 2594 1 2594 2,651 1 Raised Platform 800 1 800 807 1 Performance Storage 200 1 200 234

Subtotal 3,594 3,692

Information Center 1 Instructional area 508 1 508 1 Stacks 488 1 488 1 Circulation Desk 125 1 125 1,137 Instruct/Stacks/Circulation 1 Workroom Storage 163 1 163 163 4 SC Workspace & Personal Storage 100 3 300 One added to Neighborhood SC 4 SC Kitchenette Allowance 10 3 30 4 SC Collaboration Area Allowance 30 3 90 420 SC spaces combined 1 Broadcast Room 150 1 150 152

Subtotal 1,854 1,872

Physical Education

1 Gymnasium 5075 1 5075 4,063 Since school is K-2, it was agreed PE could be reduced

1 PE Storage 400 1 400 402

0.5 SC Workspace & Personal Storage 100 0 0 Added to Neighborhood SC

0.5 SC Kitchenette Allowance 10 0 0

0.5 SC Collaboration Area Allowance 30 0 0

1 PE Teacher Restroom 75 1 75 94

Subtotal 5,550 4,559

Food Service

1 Serving Line/Food Prep 1600 1 1600 1,330 1 Dishwashing 300 1 300 307 1 Dry Storage 130 1 130 164 1 Refrigerator/Freezer 130 1 130 187 1 FS Workspace/Storage 100 1 100 96 1 HC Restroom 60 1 60 44 1 Staff Lockers 80 1 80 74 1 Janitor 20 1 20 23 1 Receiving Area 100 1 100 191

Subtotal 2,520 2,416

JACOBS 3 of 3

Program Comparison Corrected DB RFP - 8/11/2015

Space UNIT SF UNITS Sub Total Program SF Comments Corrected DB RFP Deliverable Plan

Program for Design SF

Student Support Spaces

Administration 1 Waiting Area 200 1 200 1 Reception Counter 100 1 100 2 Clerical Work Area 100 2 200 502 Wait/Recept/Clerical 1 Registrar Office 100 1 100 103

1 Secretary's office 0 1 0 Not included in program due to school capacity

1 Principal's Office 200 1 200 204

1 AP Office 0 1 0 Not included in program due to school capacity

1 Conference Room 200 1 200 201 1 Student Records Room 75 1 75 77 1 Work/Copy Room 100 1 100 110 1 Mail Room 100 1 100 101 Suite Circulation Markup 191 1 191 Admin circulation included in gross s.f.

Subtotal 1,466 1,298

Miscellaneous Spaces 1 Schools Officer Workspace/Storage 0 1 0 1 Parents' Center 200 1 200 230 Central Workroom 200 1 200 200

2nd Floor Workroom 100 1 100 Concept is a one story facility - sf deducted out of total

Shared Conference Room (Guidance-SPED) 200 1 200 209

Guidance Counseling Reception/Waiting Area 100 1 100 - Combined with Spec Ed Waiting Psychologist Workspace/Storage 100 1 100 101 Counselor Workspace/Storage 100 1 100 101

300 202 Special Education Suite

Working/Waiting Area 100 1 100 476 Included Guidance Waiting and Circulation Assessor Workspace/Storage 100 1 100 101 Assessment Space 100 1 100 101 Lockable Storage 75 1 75 75

375 753

Health Services Nurse Workspace/Storage 50 1 50 50 Treatment Area 275 1 275 275 Restroom 65 1 65 53 Storage 50 1 50 49 Waiting Area 0 0 Large School Allowance 0 0

440 427

Janitorial Workroom 150 1 150 165 Maintenance Support 200 1 200 243

Central Storage Area 525 1 525 649 Storage/Supply Tech at receiving area Supply Tech Workspace/Storage 100 1 100 -

975 1,057

Main Telecom Room 200 1 200 219 AT Workspace (desk/repair/supplies) 300 1 300 303

Net S.F. 54,046 59,189 Concept includes circulation in Hub and Neighborhoods

Gross S.F. 19,997 14,683 74,042

2 story Allow 2,702

PA Total 76,744 Per 1391 deduct -2702 Deduct allocation for "2 Story Alllowance" deduct -100 Deduct allocation for "2nd Floor Workroom"

Design to Total 73,942 73,872

APPENDIX B

(not used)

APPENDIX C

ROOM DATA SHEETS

Replace Pierce Terrace Elementary School Date: 8/6/2015

ROOM NAME: Administration Reception / Clerical / Waiting ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10'-0" Finishes:

Floor: Rubber tile, VCT, carpet, or ceramic tile Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base cabinets

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing: N/A ELECTRICAL: Remarks:

Power: 120 VAC

Lighting, FC: 10 FC Waiting Area / 40 FC Task @ 30" Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Phone,and dedicated 911 access.

Public Address: PA, IC, Clock Master Station and Controls

Intercom: Master Station Location Data: Data connections at counter and other clerical areas. Wireless video and printer connections.

Access Security: Video Intercom (Ai Phone) Master Station with door release button.

EQUIPMENT Remarks

Per DoDEA standards. A portion of this counter shall be at appropriate height for grades PreK- 2 and meet accessibility requirements at all locations.

Narrow vision lite

To underside of deck

Provide per latest DoDEA Guidance.

Minimum 1 duplex outlet for every 10 feet of wall space.

Duress button Clock synchronized with the PA/Bell System.

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

ROOM NAME: Art ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10'-0" Finishes:

Floor: Hardened concrete, rubber tile or VCT

Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; in Art room and Art Workroom/Storage provided base & wall cabinets and/or tall storage cabinet

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.18 CFM/SF Plumbing: HW/CW/SK/Solids Interceptor Kiln has quench sink ELECTRICAL: Remarks:

Power: 120 VAC, 208 VAC, 3 Phase (Kiln)

Lighting, FC: 40 FC horiz. @ 30"/30 FC vert. @ 42" Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button Data: IWB, video, wireless, network printer, and data outlets

CCTV N/A

EQUIPMENT Remarks Provide per latest DoDEA Guidance.

Dedicated power to kiln and kiln accessory items including exhaust.

Minimum 1 duplex outlet for every 10 feet of wall space.

2-way speakers in center of room.

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

Clock synchronized with the PA/Bell System.

Narrow vision lite

Per DoDEA guidance

Kiln room shall have hardened concrete.

Vent kiln to exterior.

To underside of deck

ROOM NAME: Commons ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. Commons and Multipurpose: 12'-0" Finishes:

Floor: Porcelain tile, rubber tile or VCT Storage: porcelain tile, hardened concrete, rubber tile or VCT

Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork:

Partition Type: Gypsum wallboard over studs, solid operable partitions

Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing: CW/EDF ELECTRICAL: Remarks:

Power: 120 VAC

Lighting, FC: 10 FC General / 50 FC Active Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, wireless, network printer, and data outlets

CCTV N/A

EQUIPMENT Remarks

Narrow vision lite

To underside of deck

Provide per latest DoDEA guidance.

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Computing Center ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10'-0" Finishes:

Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs, solid operable partitions Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing: N/A ELECTRICAL: Remarks:

Power: 120 VAC

Lighting, FC: 40 FC horiz. @30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, wireless, network printer, and data outlets

CCTV N/A

EQUIPMENT Remarks

Dedicated 20A, 120 VAC for Lap Top charging station (COW).

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

To underside of deck

Provide per latest DoDEA guidance.

Per DoDEA standards

Principal requested rubber tile.

Narrow vision lite

ROOM NAME: Conference Room ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Carpet, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM /Person + 0.06 CFM/SF Plumbing:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 30 FC horiz. @ 30"/ 7.5 FC vert. @ 48" Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, wireless, network printer, and data outlets

CCTV N/A

EQUIPMENT Remarks

Provide per latest DoDEA Guidance.

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

ROOM NAME: Electrical Room ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. Exposed structure Finishes:

Floor: Sealed concrete Base: Coved vinyl or rubber base Walls: Paint, low VOC, semi-gloss Ceiling: Exposed structure Window Treatment: N/A Doors: Painted steel doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 0.06 CFM/SF Plumbing: N/A Other:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 20 FC horiz. @ 30"/5FC vert. @ 42" Outlets: General Purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, Per DoDEA IT matrix a clock is required.

Intercom: IC Data: (1) Data

CCTV N/A

EQUIPMENT Remarks

Clock synchronized with the PA/Bell System.

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems

ROOM NAME: Entrance Lobby/Corridor ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. Lobby: 12'-0" Ft.

Corridors: 10'-0" Ft.

Finishes:

Floor: Porcelain tile, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss and/or ceramic tile

Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors / alum storefront Hardware: InstaKey locking system Millwork: Provide per latest DoDEA Guidance.

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 0.06 CFM/SF Plumbing: N/A ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 10 FC horiz./5 FC vert.

Outlets: General Purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone:

Public Address: PA and Clock

Intercom:

Data:

Access Security: Video Intercom (Ai Phone) at Admin entrance door

EQUIPMENT Remarks

Narrow vision lite

To underside of deck

Provide per latest DoDEA Guidance.

At floor level

Double-sided clocks installed perpendicular to wall.

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Group Learning ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10'-0" Finishes:

Floor: Rubber tile, VCT, or carpet, area rug (optional)

Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Per DoDEA Guidance Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks

See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.

Provide per latest DoDEA Guidance.

See A-401.

See A-401. Clock synchronized with the PA/Bell System.

See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

See A-401.

To underside of deck

Provide interactive whiteboard with projection arm; white markerboard and tackboard.

ROOM NAME: Information Center ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 12'-0" Finishes:

Floor: Carpet, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:

Power: 120 VAC

Lighting, FC: 40 FC horiz. @ 30" / 7.5 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Phone at circulation desk Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks

Per DoDEA Guidance Provide portion of counter to be appropriate height for grades PreK- 2 and meet accessibility requirements.

Built-in base cabinets with counter area for circulation desk.

Principal requested carpet tile.

Narrow vision lite

To underside of deck

Provide white markerboard, and tackboard. Staff area provide interactive whiteboard w/projection arm. At Stacks/Circulation desk provide television and mounting bracket.

Dedicated 20A, 120 VAC for Lap Top charging station (COW).

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Janitor's Closet ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. Exposed structure Finishes:

Floor: Hardened concrete, quarry tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss and/or ceramic tile

Ceiling: Exposed Structure Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs or CMU Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 1 CFM / SF (Exhaust) Plumbing: HW/CW/MS ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 10 FC Outlets: General Purpose GFC I Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: N/A Public Address: N/A Intercom: N/A Data: N/A

CCTV N/A

EQUIPMENT Remarks

All surfaces should be easily cleaned and long wearing.

To underside of deck

Provide per latest DoDEA Guidance.

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Kitchen ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10'-0" Finishes:

Floor: Quarry tile Base: Coved quarry tile base Walls: Ceramic tile Ceiling: Scrubbable, 2x2 white acoustical, lay-in Window Treatment: N/A Doors: Painted hollow metal doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs; CMU Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 0.7 CFM/SF (Exhaust) Plumbing: HW/CW/SK/FD/FS/WC/LV Other:

ELECTRICAL: Remarks:

Power: 208Y / 120 VAC, 3 phase, 4 wire Lighting, FC: 50 FC horiz./20 FC vert.

Outlets: General Purpose GFCI and special purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Phone in office Public Address: PA, and Clock

Intercom: Intercom button in office 2-way speakers in center of room.

Data: Wireless, video, network printer and data outlets for the serving line, food prep, and office

Access Security: Video Intercom (Ai Phone) Other: Door bell at loading dock entrance EQUIPMENT Remarks

Locate convenient to group toilets.

To underside of deck

In Food Service Office provide tackboard and data outlets.

In Restroom and Staff Lockers provide public-address system. In Staff Lockers provide clock. In Receiving provide phone and public address- intercom-clock system. In Food Preparations/ Dishwashing/Dry Storage provide public address-clock system.

Provide (6) double tier lockers.

At food preparation surface

Clock synchronized with the PA/Bell System.

Per kitchen designer and latest DoDEA Guidance. Serving tray height sized for PreK-2

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Learning Hub ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10 Ft.

Finishes:

Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad, Custom grade; base and wall cabinets, tall storage cabinets and/or shelves

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK/EDF ELECTRICAL: Remarks:

Power: 120 VAC

Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone See A-401.

Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV See A-401.

EQUIPMENT Remarks

Dedicated 20A, 120 VAC for Lap Top charging station (COW).

See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.

See A-401. Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance

See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

To underside of deck

Provide television and mounting bracket, interactive whiteboard w/ projection arm, public address intercom, clock & bell system, white markerboard and tackboard. Provide towel dispenser and soap dispenser @ sink and dishwasher, refrigerator and small range and hood in neighorhood serving Pre-K and Kindergarten students.

Per DoDEA Guidance

Room darkening

ROOM NAME: Learning Studio - Pre-K, K, 1, 2 ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10'-0" Finishes:

Floor: Rubber tile, or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs, solid operable partitions, glass operable partitions Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks

See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.

Provide per latest DoDEA Guidance

See A-401.

See A-401. Clock synchronized with the PA/Bell System.

See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

See A-401.

To underside of deck

Provide interactive whiteboard with projection arm; white markerboard and tackboard.

Per DoDEA standards

ROOM NAME: LIMM

ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad, Custom grade, base and wall cabinets, tall storage cabinets and/or shelves

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / 0.12 CFM/SF Plumbing: CW/HW/SK Other:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Washer/Dryer

Provide interactive whiteboard/projection arm; markerboard;

tackboard; phone; washer and dryer. Provide adjustable height freestanding changing table.

Per DoDEA standards

All surfaces shall be easily cleaned and long wearing.

Provide per latest DoDEA Guidance

ROOM NAME: Mail/Work Room ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Rubber tile, VCT or carpet Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Base cabinets w/counters Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / 0.06 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 30 FC @ floor level Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: Video, jnetwork printer, and data outlets

CCTV N/A

EQUIPMENT Remarks

Per DoDEA Guidance

Narrow vision lite

To underside of deck

Provide public address intercom-clock & bell system and phone, mailboxes. Provide counter or table for sorting mail.

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Mechanical Room ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. Exposed structure Finishes:

Floor: Sealed concrete Base: Coved vinyl or rubber base Walls: Paint, low VOC, semi-gloss Ceiling: Exposed structure Window Treatment: N/A Doors: Painted steel doors Hardware: InstaKey locking system Millwork: N/A Partition Type: CMU or Gypsum wallboard over studs Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 0.06 CFM/SF Plumbing: CW/HB/FD Other:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 20 FC horiz. @ 30"/5 FC vert. @ 42" Outlets: General Purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA and Clock

Intercom: IC Data: 1 data

CCTV N/A

EQUIPMENT Remarks

To underside of deck

Clock synchronized with the PA/Bell System.

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Multipurpose / Platform / Performance Storage ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 12'-0"; Storage: 10'-0" Finishes:

Floor: Dining/Assembly: Porcelain tile, rubber tile or

VCT

Raised platform: rubber tile or VCT

Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in and/or Gypsum board Window Treatment: Electrically operated shades or blinds at clerestory Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade Partition Type: Gypsum wallboard over studs; Solid operable partition Exterior Glazing: Insul. clerestory glazing to meet ATFP reqts Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 7.5 CFM / Person + 0.18 CFM/SF Plumbing: CW/EDF ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 15 FC Ambient / 50 FC Dining/50 FC Speaker Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB,m video, network printer, wireless and data outlets

CCTV

EQUIPMENT Remarks

In Dining Multipurpose provide television and mounting bracket, independent sound system, white markerboard, tackboard. On raised platform provide independant sound system, large, electrically operated, projector screen (min 10'x10') w/ceiling mounted projector.

Theatrical lighting for stage

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

To underside of deck

ROOM NAME: Music/ Music Storage ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. Provide ceiling height 12' minimum.

Music Storage Room: 10'-0" Finishes:

Floor: Rubber tile, VCT, or carpet

Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors-sound rated door w/ same rating as walls Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, Network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks

Provide appropriate acoustical treatment.

Per DoDEA standards

Narrow vision lite

To underside of deck

In Music Room provide interactive white board with projection arm;

public address-intercom-clock & bell system; white markerboard;

tackboard; and sliding white marker board with one panel w/ permanent staff markings. In Music Storage Room provide tackboard and white marker board.

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance.

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: One on One ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Rubber tile, VCT, or carpet

Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Per DoDEA Guidance Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: Video and data outlets

CCTV N/A

EQUIPMENT Remarks

Provide interactive whiteboard with projection arm; white markerboard and tackboard.

Narrow vision lite

To underside of deck

See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.

Provide per latest DoDEA Guidance

See A-401.

See A-401. Clock synchronized with the PA/Bell System.

See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

See A-401.

ROOM NAME: OT/PT / Observation ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 10'-0" Finishes:

Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & wall cabinets and/or tall storage cabinet

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace Acoustical Requirements" in Appendix D

MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / 0.06 CFM/SF Plumbing: - ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 15 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks

Provide interactive whiteboard with projection arm; white markerboard;

tackboard; provide ceiling hook (two locations preferred for flexibility in arranging the room), provide structural support for both hook locations.

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

To underside of deck Provide one-way glass to view OT/PT from Observation room.

ROOM NAME: Physical Education Space ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. PE Space: 24'-0"

Storage: 10'-0" Finishes:

Floor: PE Space: Sports floor; Storage: Hardened concrete, rubber tile or VCT Base: Coved vinyl or rubber base Walls: Painted, low VOC, semi-gloss Ceiling: Exposed structure, painted Window Treatment: N/A Doors: Painted hollow metal doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs and CMU

Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 0.3 CFM/SF Plumbing: CW/EDF Other:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 30 FC horiz./10 FC vert.

Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV: N/A

EQUIPMENT Remarks

Hardened concrete in storage.

To underside of deck. Wall finish must be capable of enduring ball strikes. 2 layers 5/8" impact resistant GWB or perforated IR- GWB may be used above 10' AFF.

Provide television and mounting bracket, independent sound system.

6' high wall padding continuous at main court.

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance. Protect all devices from ball strikes.

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Principal's Office ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Carpet, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 30 FC horiz. @ 30"/15 FC vert. @ 42" Outlets: General Purpose

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: Video, network printer, and data outlets

Security Access: Video Intercom (Ai phone) EQUIPMENT Remarks

Per DoDEA standards

Narrow vision lite

To underside of deck

Provide television and mounting bracket; interactive whiteboard with projector arm; tackboard; markerboard; personal emergency alerting station (PEAS); controls for public address-intercom and monitor for security system.

Minimum 1 duplex outlet for every 10 feet of wall space.

Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Reading Lab ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Rubber tile, VCT, or carpet

Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Per DoDEA Guidance Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Wall mounted phone Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks

Provide interactive whiteboard with projection arm; white markerboard and tackboard.

Narrow vision lite

To underside of deck

See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.

Provide per latest DoDEA Guidance

See A-401.

See A-401. Clock synchronized with the PA/Bell System.

See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

ROOM NAME: Staff Collaboration ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Rubber tile, VCT or carpet Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad, Custom grade base and wall cabinets, tall storage cabinete and/or shelves

Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.

Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / 0.06 CFM/SF Plumbing: HW/CW/SK Other:

ELECTRICAL: Remarks:

Power: 120 VAC

Lighting, FC: 40 FC horiz. @ 30" / 15 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board

Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: Phones Public Address: PA, and Clock

Intercom: Intercom button 2-way speakers in center of room.

Data: IWB, video, network printer, wireless and data outlets

CCTV N/A

EQUIPMENT Remarks Provide interactive whiteboard with projection arm; public address-intercom-clock & bell system; white markerboard; tackboard; copy machine; refrigerator; coffeemaker and microwave.

Per DoDEA standards

Narrow vision lite

To underside of deck

(Lap top charging same as Learning Hub)

See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.

See A-401. Clock synchronized with the PA/Bell System.

Provide per latest DoDEA Guidance.

See A-401.

See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

ROOM NAME: Staff Toilets ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Porcelain tile Base: Coved tile base Walls: Ceramic tile and Paint, low VOC semi-gloss

Ceiling: Painted gyspum wallboard Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad, Custom grade Partition Type: Gypsum wallboard over studs Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 70 CFM / Fixture (Exhaust) Plumbing: HW/CW/LV/WC/FD Other:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 5 FC general/15 FC @ fixtures Outlets: General Purpose GFCI Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: N/A Public Address: PA and Clock

Intercom: N/A 2-way speakers in center of room.

Data: N/A

CCTV N/A

EQUIPMENT Remarks

To underside of deck

Provide public address-intercom system; coat/towel hook; framed mirror; grab bar; toilet tissue dispenser; soap dispenser and hand dryer.

Per DoDEA standards

Wall tile full height on wet wall and a 4"-0" AFF tile wainscot with trim and paint above on all other walls.

Toilet partitions shall be solid phenolic.

Provide per latest DoDEA Guidance

Clock synchronized with the PA/Bell System.

Refer to IT connection require-ments in IT Connection Matrix in

ROOM NAME: Storage ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. Exposed structure, painted Finishes:

Floor: Hardened concrete, rubber tile or VCT Base: Coved rubber or vinyl base Walls: Paint, Low VCC, Semi-gloss Ceiling: Exposed structure, painted Window Treatment: N/A Doors: Painted hollow metal doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs or CMU Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D

MECHANICAL: Remarks:

Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 0.12 CFM/SF Plumbing: N/A Other:

ELECTRICAL: Remarks:

Power: 120 VAC Lighting, FC: 10 FC horiz. @ floor/3 FC vert. @ 48" Outlets: General Purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:

Telephone: N/A Public Address: N/A Intercom: N/A Data: N/A

CCTV N/A

EQUIPMENT Remarks

To underside of deck

Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).

ROOM NAME: Student Toilets ARCHITECTURAL: Remarks:

Minimum Ceiling Ht. 9'-0" Finishes:

Floor: Porcelain tile Base: Coved tile base Walls: Ceramic tile and paint low VOC semi-gloss

Ceiling: Painted gyspum wallboard Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad, Custom grade Partition Type: Gypsum wallboard over studs Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace

Acoustical Requirements" in Appendix D MECHANICAL: Remarks:

Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F…

This is the start of the file's text. The full file is on GovTribe.