15R12Ph2vol2.pdf
PDF 25 MB Posted
- Attached to
- Replace Pierce Terrace Elementary School Federal contract opportunity
- Solicitation number
- W912HN-15-R-0012
About this file
SPECS Vol 2 Amd 4
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| amd_6.pdf | ||
| 15R12Ph2vol1.pdf | ||
| amd5.pdf | ||
| Amd4.pdf | ||
| W912HN-15-R-0012_AMD4.PDF | ||
| 15R12Ph2vol1.pdf | ||
| 15R12Ph2vol1.pdf | ||
| amd3.pdf | ||
| 15R12Ph2vol2.pdf | ||
| W912HN-15-R-0012_FIO_AMD2.pdf | ||
| AMD2.pdf | ||
| W912HN-15-R-0012_AMD2.PDF | ||
| 15R12Ph2vol1.pdf | ||
| amd1.pdf | ||
| W912HN-15-R-0012_Solicitation.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(Revised by Amendment 0002)
Fort Jackson, South Carolina
Solicitation Number
W912HN-15-R-0012
Replace Pierce Terrace Elementary School Volume 2 of 2: Appendices
PN AM00035
March 2016
*2 PHASE TWO OF TWO PHASE
DESIGN/BUILD SUBMITTAL PROCEDURE
This acquisition is being solicited on an unrestricted basis as full and open competition, but contains a HubZone Price Evaluation Preference
U.S. ARMY ENGINEER DISTRICT, SAVANNAH
CORPS OF ENGINEERS
100 WEST OGLETHORPE AVENUE
SAVANNAH, GEORGIA 31401-3640
US Army Corps of Engineers Savannah District
Table of Contents - Page 1
PROJECT TABLE OF CONTENTS
SPECIFICATIONS
01 11 00 SUMMARY OF WORK
01 14 00 WORK RESTRICTIONS
01 32 01.00 10 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
01 33 16 DESIGN AFTER AWARD
01 33 29.10 LEED(TM) DOCUMENTATION
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 10 QUALITY CONTROL
01 45 00.10 10 QUALITY CONTROL SYSTEM (QCS)
01 45 35 SPECIAL INSPECTION FOR SEISMIC-RESISTING SYSTEMS
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19.11 INDOOR AIR QUALITY (IAQ) MANAGEMENT
01 57 20.00 10 ENVIRONMENTAL PROTECTION
01 62 35.10 RECYCLED/RECOVERED/BIOBASED MATERIALS
01 74 19.10 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT
01 78 00 CLOSEOUT SUBMITTALS
01 83 16.10 EXTERIOR ENCLOSURE PERFORMANCE REQUIREMENTS
02 41 00 DEMOLITION
APPENDICES
Appendix A School Program Requirements Appendix B Not Used Appendix C Room Data Sheets Appendix D Acoustical Requirements Appendix E Sustainable Design Information Appendix F Utilities Points of Contact DPW Utility Rates Appendix G Subsurface Exploration Report Finding of No Significant Impact Wetlands Preliminary Jurisdictional Determination Appendix H AHERA Survey Asbestos Survey Reports Appendix I Fire Protection: Fire Flow Tests Appendix J Site Communications Services Connection Location Appendix K Specification 1140 00 Food Service Equipment Appendix L Life Cycle Cost Analysis Fuel Cost Information Appendix M Gymnasium and Play Court Floor Graphics Appendix N Fort Jackson Installation Design Guide Appendix O Context Photos Key Context Photo Thumbnails Appendix P Erosion Control Appendix Q Geothermal Test Loop Installation and Thermal Conductivity
Test Appendix R Fort Jackson Stormwater Runoff Requirements Appendix S DDESS Antiterrorism, Security & Safety Office Construction
Guide DoDEA Security Engineering Design/ Planning Baseline DDESS Lockdown Shelter-In-Place Requirements
Table of Contents - Page 2
Appendix T Supplementary Instructions to the Savannah District Design Manual for Military Construction
Appendix U DoDEA Approved Software Appendix V Environmental Condition of Property Report
-- End of Project Table of Contents --
Fort Jackson South Carolina
US Army Corps of Engineers Savannah District
Solicitation Number
W912HN-15-R-0012
Replace Pierce Terrace Elementary School
Volume 2 of 2 - Appendices
PN AM00035
12 October 2015 (RTA)
Submitted by:
Jacobs Engineering Group Inc.
Florida Architectural Corporation License #AAC001790 Florida Registered Engineering Firm 2822 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801
TEL (407) 903-5001
FAX (407) 903-5150
U.S. ARMY ENGINEER DISTRICT, SAVANNAH
CORPS OF ENGINEERS
100 WEST OGLETHORPE AVENUE
SAVANNAH, GEORGIA 31401-3640
http://en.wikipedia.org/wiki/File:United_States_Army_Corps_of_Engineers_logo.svg
Replace Pierce Terrace Elementary School W912HN-15-R-0012
Jacobs Section 01 11 00 Page 1
TABLE OF CONTENTS
Volume 1
Division 00 General Requirements (To be provided by USACE at later date)
00 21 00 Instructions, Conditions & Notices to Offerors 00 22 20 Phase 2 Design-Build Selection Procedures 00 45 00 Representations and Certifications 00 72 11 Contract Clauses 00 73 00 Special Contract Requirements
Division 01 General Requirements
01 11 00 Summary of Work
Chapter 1 Project Objectives Chapter 2 Building Functional and Area Requirements Chapter 3 Site Planning and Design Chapter 4 Site Engineering Chapter 5 Architectural Design Chapter 6 Equipment and Furnishings Chapter 7 Food Service Equipment Chapter 8 Structural Design Chapter 9 Thermal Performance Chapter 10 Plumbing Systems Chapter Chapter 11 Electrical Systems Chapter 12 Heating, Ventilating and Air Conditioning Systems Chapter Chapter13 Energy Conservation/Sustainable Design Chapter 14 Fire Protection Systems Chapter 15 Environmental Protection Chapter 16 Applicable Criteria
01 14 00 Work Restrictions 01 32 01.00 10 Project Schedule 01 33 00 Submittal Procedures 01 33 16 Design After Award
• Attachment A Structural Interior Design (SID) Requirements
• Attachment B Not Used
• Attachment C Tracking Comments in DR Checks
• Attachment D Sample Fire Protection and Life Safety Code
Review
• Attachment E Building Information Modeling Requirements
• Attachment F Analysis of Window Unit Structural Support
• Attachment G Design Submittal Directory and Subdirectory
File Arrangement
Jacobs Section 01 11 00 Page 2
01 33 29.10 LEED Documentation 01 35 26 Governmental Safety Requirements 01 42 00 Sources for Reference Publications 01 45 00.00 10 Quality Control 01 45 00.10 10 Quality Control System (QCS) 01 45 35 Special Inspections for Seismic- Resisting Systems 01 50 00 Temporary Construction Facilities and Controls 01 57 19.11 Indoor Air Quality (IAQ) Management 01 57 20.00 10 Environmental Protection 01 62 35.10 Recycled/Recovered Bio-based Materials 01 74 19.10 Construction and Demolition Waste Management 01 78 00 Closeout Submittals 01 83 16.10 Exterior Enclosure Performance Requirements
Division 02
02 41 00 Demolition
Volume 2
Appendices
Appendix A School Program Requirements
Appendix B Not Used
Appendix C Room Data Sheets
Appendix D Acoustical Requirements
Appendix E Sustainable Design Information:
LEED Registration Information LEED for Schools 2009 Checklist Owners Project Requirements DoDEA Administrative Instruction: Sustainability and Energy Efficiency Program USACE Air Leakage Test Protocol for Leakage in Building Envelopes
Appendix F Utilities Points of Contact DPW Utility Rates
Appendix G Subsurface Exploration Report Finding of No Significant Impact Wetlands Preliminary Jurisdictional Determination
Appendix H AHERA Survey: Pierce Terrace Elementary School Asbestos Survey Reports Pierce Terrace Elementary School
Appendix I Fire Protection: Fire Flow Tests
Jacobs Section 01 11 00 Page 3
Appendix J Site Communications Services Connection Location
Appendix K Specification 1140 00 Food Service Equipment
Appendix L Life Cycle Cost Analysis Fuel Cost Information
Appendix M Gymnasium and Play Court Floor Graphics
Appendix N Fort Jackson Installation Design Guide
Appendix O Context Photos Key Context Photo Thumbnails
Appendix P Erosion Control
Appendix Q Geothermal Test Loop Installation and Thermal Conductivity Test
Appendix R Fort Jackson Stormwater Runoff Requirements
Appendix S DDESS Antiterrorism, Security & Safety Office Construction Guide DoDEA Security Engineering Design/ Planning Baseline DDESS Lockdown Shelter-In-Place Requirements
Appendix T Supplementary Instructions to the Savannah District Design Manual for Military Construction
Appendix U DoDEA Approved Software
Appendix V Environmental Condition of Property Report
APPENDIX A
SCHOOL PROGRAM REQUIREMENTS
JACOBS 1 of 3
Pierce Terrace Elementary School Program Comparison Corrected DB RFP - 8/11/2015
Space UNIT SF UNITS Sub Total Program SF Comments
Neighborhood 1 1 Learning Studio 900 1 900 900 2 Learning Studio 900 1 900 900 3 Learning Studio - PSCD 900 1 900 900 4 Learning Studio 900 1 900 900 Learning Hub Allowance 350 4 1,400 2,168 Concept SF includes circulation Group Learning Allowance 50 4 200 200 One-to-One Allowance 25 4 100 124
Staff Collaboration 875 884 Staff collaboration spaces combined into one room
SC Workspace & Personal Storage 100 5 500 SC Kitchenette Allowance 10 5 50 SC Collaboration Area Allowance 30 5 150 SC Shared Storage Allowance 35 5 175
Neighborhood 2 5 Learning Studio 900 1 900 900 6 Learning Studio 900 1 900 900 7 Learning Studio 900 1 900 900 8 Learning Studio 900 1 900 900 Learning Hub Allowance 350 4 1,400 2,704 Concept SF includes circulation Group Learning Allowance 50 4 200 241 One-to-One Allowance 25 4 100 129
Staff Collaboration 1,347.5 1,400 Staff collaboration spaces combined into one room
SC Workspace & Personal Storage 100 8 800 SC Kitchenette Allowance 10 8 80 SC Collaboration Area Allowance 30 8 240
SC Shared Storage Allowance 35 6.5 227.5 Storage not included for PE, Art, Music
Neighborhood 3 9 Learning Studio 900 1 900 900 10 Learning Studio 900 1 900 900 11 Learning Studio 900 1 900 900 12 Learning Studio 900 1 900 900
Learning Hub Allowance 350 4 1,400 2,738 Concept SF includes circulation Group Learning Allowance 50 4 200 241 One-to-One Allowance 25 4 100 122
Staff Collaboration 1,190 1,226 Staff collaboration spaces combined into one room
SC Workspace & Personal Storage 100 7 700 SC Kitchenette Allowance 10 7 70 SC Collaboration Area Allowance 30 7 210
SC Shared Storage Allowance 35 6 210 Storage not included for itinerant from IC
Neighborhood 4 13 Learning Studio 900 1 900 900 14 Learning Studio 900 1 900 900 15 Learning Studio 900 1 900 900 16 Learning Studio 900 1 900 900 17 Learning Studio 900 1 900 900
Learning Hub Allowance 350 5 1,750 2,396 Concept SF includes circulation Group Learning Allowance 50 5 250 250 One to one 25 5 125 127
1,225 1,225 Staff collaboration spaces combined into one room
SC Workspace & Personal Storage 100 7 700 SC Kitchenette Allowance 10 7 70 SC Collaboration Area Allowance 30 7 210 SC Shared Storage Allowance 35 7 245
Learning Impaired - Mild/Moderate 400 1 400 404 Reading Lab 400 1 400 417
Learning Impaired Moderate/Severe 1 SC Workspace & Personal Storage 100 0 0 1 SC Kitchenette Allowance 10 0 0 1 SC Collaboration Area Allowance 30 0 0 1 SC Shared Storage Allowance 35 0 0 SC spaces combined with SC4 1 Student Instruction Area 1000 1 1000 1,222 Instruct/Kitchen 1 Kitchen 275 1 275 1 HC Restroom 75 1 75 58 1 Changing & Shower Area 75 1 75 92
Subtotal 1,425 1,372
Corrected DB RFP Deliverable Plan
Program for Design SF
JACOBS 2 of 3
Program Comparison Corrected DB RFP - 8/11/2015
Space UNIT SF UNITS Sub Total Program SF Comments Corrected DB RFP Deliverable Plan
Program for Design SF
Exploratory Learning Spaces 1 Computing Center 1200 1 1,200 1,203
Art Room SC Workspace & Personal Storage 100 0 0 Added to Neighborhood SC SC Kitchenette Allowance 10 0 0 SC Collaboration Area Allowance 30 0 0 Art Classroom 1000 1 1000 1,004 Kiln 100 1 100 125 Art Workroom/Storage 200 1 200 201 Subtotal 1,300 1,330
Music Suite SC Workspace & Personal Storage 100 0 0 Added to Neighborhood SC SC Kitchenette Allowance 10 0 0 SC Collaboration Area Allowance 30 0 0 Music Room 1000 1 1000 1,003 Music StoragevRoom 250 1 250 251 Subtotal 1,250 1,254
OT/PT
1 Therapy Area 800 1 800 802 1 Workspace/Storage/Observation 400 1 400 400
Subtotal 1,200 1,202
Commons 1 Commons 1284 1 1284 1 Recycle Area 150 1 150
Subtotal 1,434 3,095 Concept SF includes circulation and allocation from reduced PE
Multipurpose Room 1 Multipurpose Room 2594 1 2594 2,651 1 Raised Platform 800 1 800 807 1 Performance Storage 200 1 200 234
Subtotal 3,594 3,692
Information Center 1 Instructional area 508 1 508 1 Stacks 488 1 488 1 Circulation Desk 125 1 125 1,137 Instruct/Stacks/Circulation 1 Workroom Storage 163 1 163 163 4 SC Workspace & Personal Storage 100 3 300 One added to Neighborhood SC 4 SC Kitchenette Allowance 10 3 30 4 SC Collaboration Area Allowance 30 3 90 420 SC spaces combined 1 Broadcast Room 150 1 150 152
Subtotal 1,854 1,872
Physical Education
1 Gymnasium 5075 1 5075 4,063 Since school is K-2, it was agreed PE could be reduced
1 PE Storage 400 1 400 402
0.5 SC Workspace & Personal Storage 100 0 0 Added to Neighborhood SC
0.5 SC Kitchenette Allowance 10 0 0
0.5 SC Collaboration Area Allowance 30 0 0
1 PE Teacher Restroom 75 1 75 94
Subtotal 5,550 4,559
Food Service
1 Serving Line/Food Prep 1600 1 1600 1,330 1 Dishwashing 300 1 300 307 1 Dry Storage 130 1 130 164 1 Refrigerator/Freezer 130 1 130 187 1 FS Workspace/Storage 100 1 100 96 1 HC Restroom 60 1 60 44 1 Staff Lockers 80 1 80 74 1 Janitor 20 1 20 23 1 Receiving Area 100 1 100 191
Subtotal 2,520 2,416
JACOBS 3 of 3
Program Comparison Corrected DB RFP - 8/11/2015
Space UNIT SF UNITS Sub Total Program SF Comments Corrected DB RFP Deliverable Plan
Program for Design SF
Student Support Spaces
Administration 1 Waiting Area 200 1 200 1 Reception Counter 100 1 100 2 Clerical Work Area 100 2 200 502 Wait/Recept/Clerical 1 Registrar Office 100 1 100 103
1 Secretary's office 0 1 0 Not included in program due to school capacity
1 Principal's Office 200 1 200 204
1 AP Office 0 1 0 Not included in program due to school capacity
1 Conference Room 200 1 200 201 1 Student Records Room 75 1 75 77 1 Work/Copy Room 100 1 100 110 1 Mail Room 100 1 100 101 Suite Circulation Markup 191 1 191 Admin circulation included in gross s.f.
Subtotal 1,466 1,298
Miscellaneous Spaces 1 Schools Officer Workspace/Storage 0 1 0 1 Parents' Center 200 1 200 230 Central Workroom 200 1 200 200
2nd Floor Workroom 100 1 100 Concept is a one story facility - sf deducted out of total
Shared Conference Room (Guidance-SPED) 200 1 200 209
Guidance Counseling Reception/Waiting Area 100 1 100 - Combined with Spec Ed Waiting Psychologist Workspace/Storage 100 1 100 101 Counselor Workspace/Storage 100 1 100 101
300 202 Special Education Suite
Working/Waiting Area 100 1 100 476 Included Guidance Waiting and Circulation Assessor Workspace/Storage 100 1 100 101 Assessment Space 100 1 100 101 Lockable Storage 75 1 75 75
375 753
Health Services Nurse Workspace/Storage 50 1 50 50 Treatment Area 275 1 275 275 Restroom 65 1 65 53 Storage 50 1 50 49 Waiting Area 0 0 Large School Allowance 0 0
440 427
Janitorial Workroom 150 1 150 165 Maintenance Support 200 1 200 243
Central Storage Area 525 1 525 649 Storage/Supply Tech at receiving area Supply Tech Workspace/Storage 100 1 100 -
975 1,057
Main Telecom Room 200 1 200 219 AT Workspace (desk/repair/supplies) 300 1 300 303
Net S.F. 54,046 59,189 Concept includes circulation in Hub and Neighborhoods
Gross S.F. 19,997 14,683 74,042
2 story Allow 2,702
PA Total 76,744 Per 1391 deduct -2702 Deduct allocation for "2 Story Alllowance" deduct -100 Deduct allocation for "2nd Floor Workroom"
Design to Total 73,942 73,872
APPENDIX B
(not used)
APPENDIX C
ROOM DATA SHEETS
Replace Pierce Terrace Elementary School Date: 8/6/2015
ROOM NAME: Administration Reception / Clerical / Waiting ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10'-0" Finishes:
Floor: Rubber tile, VCT, carpet, or ceramic tile Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base cabinets
Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing: N/A ELECTRICAL: Remarks:
Power: 120 VAC
Lighting, FC: 10 FC Waiting Area / 40 FC Task @ 30" Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Phone,and dedicated 911 access.
Public Address: PA, IC, Clock Master Station and Controls
Intercom: Master Station Location Data: Data connections at counter and other clerical areas. Wireless video and printer connections.
Access Security: Video Intercom (Ai Phone) Master Station with door release button.
EQUIPMENT Remarks
Per DoDEA standards. A portion of this counter shall be at appropriate height for grades PreK- 2 and meet accessibility requirements at all locations.
Narrow vision lite
To underside of deck
Provide per latest DoDEA Guidance.
Minimum 1 duplex outlet for every 10 feet of wall space.
Duress button Clock synchronized with the PA/Bell System.
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
ROOM NAME: Art ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10'-0" Finishes:
Floor: Hardened concrete, rubber tile or VCT
Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; in Art room and Art Workroom/Storage provided base & wall cabinets and/or tall storage cabinet
Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.18 CFM/SF Plumbing: HW/CW/SK/Solids Interceptor Kiln has quench sink ELECTRICAL: Remarks:
Power: 120 VAC, 208 VAC, 3 Phase (Kiln)
Lighting, FC: 40 FC horiz. @ 30"/30 FC vert. @ 42" Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button Data: IWB, video, wireless, network printer, and data outlets
CCTV N/A
EQUIPMENT Remarks Provide per latest DoDEA Guidance.
Dedicated power to kiln and kiln accessory items including exhaust.
Minimum 1 duplex outlet for every 10 feet of wall space.
2-way speakers in center of room.
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
Clock synchronized with the PA/Bell System.
Narrow vision lite
Per DoDEA guidance
Kiln room shall have hardened concrete.
Vent kiln to exterior.
To underside of deck
ROOM NAME: Commons ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. Commons and Multipurpose: 12'-0" Finishes:
Floor: Porcelain tile, rubber tile or VCT
Storage: porcelain tile, hardened concrete, rubber tile or VCT
Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork:
Partition Type: Gypsum wallboard over studs, solid operable partitions Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing: CW/EDF ELECTRICAL: Remarks:
Power: 120 VAC
Lighting, FC: 10 FC General / 50 FC Active Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, wireless, network printer, and data outlets
CCTV N/A
EQUIPMENT Remarks
Narrow vision lite
To underside of deck
Provide per latest DoDEA guidance.
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Computing Center ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10'-0" Finishes:
Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs, solid operable partitions Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing: N/A ELECTRICAL: Remarks:
Power: 120 VAC
Lighting, FC: 40 FC horiz. @30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, wireless, network printer, and data outlets
CCTV N/A
EQUIPMENT Remarks
Dedicated 20A, 120 VAC for Lap Top charging station (COW).
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
To underside of deck
Provide per latest DoDEA guidance.
Per DoDEA standards
Principal requested rubber tile.
Narrow vision lite
ROOM NAME: Conference Room ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 9'-0" Finishes:
Floor: Carpet, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM /Person + 0.06 CFM/SF Plumbing:
ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 30 FC horiz. @ 30"/ 7.5 FC vert. @ 48" Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, wireless, network printer, and data outlets
CCTV N/A
EQUIPMENT Remarks Provide per latest DoDEA Guidance.
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
ROOM NAME: Electrical Room ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. Exposed structure Finishes:
Floor: Sealed concrete Base: Coved vinyl or rubber base Walls: Paint, low VOC, semi-gloss Ceiling: Exposed structure Window Treatment: N/A Doors: Painted steel doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 0.06 CFM/SF Plumbing: N/A Other:
ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 20 FC horiz. @ 30"/5FC vert. @ 42" Outlets: General Purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, Per DoDEA IT matrix a clock is required.
Intercom: IC Data: (1) Data
CCTV N/A
EQUIPMENT Remarks
Clock synchronized with the PA/Bell System.
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems
ROOM NAME: Entrance Lobby/Corridor ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. Lobby: 12'-0" Ft.
Corridors: 10'-0" Ft.
Finishes:
Floor: Porcelain tile, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss and/or ceramic tile
Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors / alum storefront Hardware: InstaKey locking system Millwork: Provide per latest DoDEA Guidance.
Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 0.06 CFM/SF Plumbing: N/A ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 10 FC horiz./5 FC vert.
Outlets: General Purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone:
Public Address: PA and Clock
Intercom:
Data:
Access Security: Video Intercom (Ai Phone) at Admin entrance door
EQUIPMENT Remarks
Narrow vision lite
To underside of deck
Provide per latest DoDEA Guidance.
At floor level
Double-sided clocks installed perpendicular to wall.
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Group Learning ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10'-0" Finishes:
Floor: Rubber tile, VCT, or carpet, area rug
(optional) Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Per DoDEA Guidance Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV N/A
EQUIPMENT Remarks
See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.
Provide per latest DoDEA Guidance.
See A-401.
See A-401. Clock synchronized with the PA/Bell System.
See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
See A-401.
To underside of deck
Provide interactive whiteboard with projection arm; white markerboard and tackboard.
ROOM NAME: Information Center ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 12'-0" Finishes:
Floor: Carpet, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves
Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:
Power: 120 VAC
Lighting, FC: 40 FC horiz. @ 30" / 7.5 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Phone at circulation desk Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV N/A
EQUIPMENT Remarks
Per DoDEA Guidance Provide portion of counter to be appropriate height for grades PreK- 2 and meet accessibility requirements.
Built-in base cabinets with counter area for circulation desk.
Principal requested carpet tile.
Narrow vision lite
To underside of deck
Provide white markerboard, and tackboard. Staff area provide interactive whiteboard w/projection arm. At Stacks/Circulation desk provide television and mounting bracket.
Dedicated 20A, 120 VAC for Lap Top charging station (COW).
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Janitor's Closet ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. Exposed structure Finishes:
Floor: Hardened concrete, quarry tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss and/or ceramic tile
Ceiling: Exposed Structure Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs or CMU Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 1 CFM / SF (Exhaust) Plumbing: HW/CW/MS ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 10 FC Outlets: General Purpose GFC I Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: N/A Public Address: N/A Intercom: N/A Data: N/A
CCTV N/A
EQUIPMENT Remarks
All surfaces should be easily cleaned and long wearing.
To underside of deck
Provide per latest DoDEA Guidance.
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Kitchen ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10'-0" Finishes:
Floor: Quarry tile Base: Coved quarry tile base Walls: Ceramic tile Ceiling: Scrubbable, 2x2 white acoustical, lay-in Window Treatment: N/A Doors: Painted hollow metal doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs; CMU Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 0.7 CFM/SF (Exhaust) Plumbing: HW/CW/SK/FD/FS/WC/LV Other:
ELECTRICAL: Remarks:
Power: 208Y / 120 VAC, 3 phase, 4 wire Lighting, FC: 50 FC horiz./20 FC vert.
Outlets: General Purpose GFCI and special purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Phone in office Public Address: PA, and Clock
Intercom: Intercom button in office 2-way speakers in center of room.
Data: Wireless, video, network printer and data outlets for the serving line, food prep, and office
Access Security: Video Intercom (Ai Phone) Other: Door bell at loading dock entrance EQUIPMENT Remarks
Locate convenient to group toilets.
To underside of deck
In Food Service Office provide tackboard and data outlets.
In Restroom and Staff Lockers provide public-address system. In Staff Lockers provide clock. In Receiving provide phone and public address- intercom-clock system. In Food Preparations/ Dishwashing/Dry Storage provide public address-clock system.
Provide (6) double tier lockers.
At food preparation surface
Clock synchronized with the PA/Bell System.
Per kitchen designer and latest DoDEA Guidance. Serving tray height sized for PreK-2
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Learning Hub ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10 Ft.
Finishes:
Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad, Custom grade; base and wall cabinets, tall storage cabinets and/or shelves
Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK/EDF ELECTRICAL: Remarks:
Power: 120 VAC
Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone See A-401.
Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV See A-401.
EQUIPMENT Remarks
Dedicated 20A, 120 VAC for Lap Top charging station (COW).
See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.
See A-401. Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance
See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
To underside of deck
Provide television and mounting bracket, interactive whiteboard w/ projection arm, public address intercom, clock & bell system, white markerboard and tackboard. Provide towel dispenser and soap dispenser @ sink and dishwasher, refrigerator and small range and hood in neighorhood serving Pre-K and Kindergarten students.
Per DoDEA Guidance
Room darkening
ROOM NAME: Learning Studio - Pre-K, K, 1, 2 ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10'-0" Finishes:
Floor: Rubber tile, or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs, solid operable partitions, glass operable partitions Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV N/A
EQUIPMENT Remarks
See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.
Provide per latest DoDEA Guidance
See A-401.
See A-401. Clock synchronized with the PA/Bell System.
See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
See A-401.
To underside of deck
Provide interactive whiteboard with projection arm; white markerboard and tackboard.
Per DoDEA standards
ROOM NAME: LIMM
ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 9'-0" Finishes:
Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad, Custom grade, base and wall cabinets, tall storage cabinets and/or shelves
Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / 0.12 CFM/SF Plumbing: CW/HW/SK Other:
ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV N/A
EQUIPMENT Remarks
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Washer/Dryer
Provide interactive whiteboard/projection arm; markerboard;
tackboard; phone; washer and dryer. Provide adjustable height freestanding changing table.
Per DoDEA standards
All surfaces shall be easily cleaned and long wearing.
Provide per latest DoDEA Guidance
ROOM NAME: Mail/Work Room ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 9'-0" Finishes:
Floor: Rubber tile, VCT or carpet Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: N/A Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Base cabinets w/counters Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / 0.06 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 30 FC @ floor level Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: Video, jnetwork printer, and data outlets
CCTV N/A
EQUIPMENT Remarks
Per DoDEA Guidance
Narrow vision lite
To underside of deck
Provide public address intercom-clock & bell system and phone, mailboxes. Provide counter or table for sorting mail.
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Mechanical Room ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. Exposed structure Finishes:
Floor: Sealed concrete Base: Coved vinyl or rubber base Walls: Paint, low VOC, semi-gloss Ceiling: Exposed structure Window Treatment: N/A Doors: Painted steel doors Hardware: InstaKey locking system Millwork: N/A Partition Type: CMU or Gypsum wallboard over studs Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 68°F ± 2°F Air Conditioning: 78°F ± 2°F Ventilation: 0.06 CFM/SF Plumbing: CW/HB/FD Other:
ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 20 FC horiz. @ 30"/5 FC vert. @ 42" Outlets: General Purpose Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA and Clock
Intercom: IC Data: 1 data
CCTV N/A
EQUIPMENT Remarks
To underside of deck
Clock synchronized with the PA/Bell System.
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Multipurpose / Platform / Performance Storage ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 12'-0"; Storage: 10'-0" Finishes:
Floor: Dining/Assembly: Porcelain tile, rubber tile or
VCT
Raised platform: rubber tile or VCT
Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in and/or Gypsum board Window Treatment: Electrically operated shades or blinds at clerestory Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade Partition Type: Gypsum wallboard over studs; Solid operable partition Exterior Glazing: Insul. clerestory glazing to meet ATFP reqts Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 7.5 CFM / Person + 0.18 CFM/SF Plumbing: CW/EDF ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 15 FC Ambient / 50 FC Dining/50 FC Speaker Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB,m video, network printer, wireless and data outlets
CCTV
EQUIPMENT Remarks
In Dining Multipurpose provide television and mounting bracket, independent sound system, white markerboard, tackboard. On raised platform provide independant sound system, large, electrically operated, projector screen (min 10'x10') w/ceiling mounted projector.
Theatrical lighting for stage
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
To underside of deck
ROOM NAME: Music/ Music Storage ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. Provide ceiling height 12' minimum.
Music Storage Room: 10'-0" Finishes:
Floor: Rubber tile, VCT, or carpet
Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors-sound rated door w/ same rating as walls Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, Network printer, wireless and data outlets
CCTV N/A
EQUIPMENT Remarks
Provide appropriate acoustical treatment.
Per DoDEA standards
Narrow vision lite
To underside of deck
In Music Room provide interactive white board with projection arm;
public address-intercom-clock & bell system; white markerboard;
tackboard; and sliding white marker board with one panel w/ permanent staff markings. In Music Storage Room provide tackboard and white marker board.
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance.
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: One on One ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 9'-0" Finishes:
Floor: Rubber tile, VCT, or carpet
Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Per DoDEA Guidance Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: Video and data outlets
CCTV N/A
EQUIPMENT Remarks Provide interactive whiteboard with projection arm; white markerboard and tackboard.
Narrow vision lite
To underside of deck
See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.
Provide per latest DoDEA Guidance
See A-401.
See A-401. Clock synchronized with the PA/Bell System.
See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
See A-401.
ROOM NAME: OT/PT / Observation ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 10'-0" Finishes:
Floor: Rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & wall cabinets and/or tall storage cabinet
Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace Acoustical Requirements" in Appendix D
MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / 0.06 CFM/SF Plumbing: - ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 15 FC vert. @ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV N/A
EQUIPMENT Remarks
Provide interactive whiteboard with projection arm; white markerboard;
tackboard; provide ceiling hook (two locations preferred for flexibility in arranging the room), provide structural support for both hook locations.
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance
Refer to IT connection require-ments in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
To underside of deck Provide one-way glass to view OT/PT from Observation room.
ROOM NAME: Physical Education Space ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. PE Space: 24'-0"
Storage: 10'-0" Finishes:
Floor: PE Space: Sports floor; Storage: Hardened concrete, rubber tile or VCT Base: Coved vinyl or rubber base Walls: Painted, low VOC, semi-gloss Ceiling: Exposed structure, painted Window Treatment: N/A Doors: Painted hollow metal doors Hardware: InstaKey locking system Millwork: N/A Partition Type: Gypsum wallboard over studs and CMU
Exterior Glazing: N/A Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 0.3 CFM/SF Plumbing: CW/EDF Other:
ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 30 FC horiz./10 FC vert.
Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV: N/A
EQUIPMENT Remarks
Hardened concrete in storage.
To underside of deck. Wall finish must be capable of enduring ball strikes. 2 layers 5/8" impact resistant GWB or perforated IR- GWB may be used above 10' AFF.
Provide television and mounting bracket, independent sound system.
6' high wall padding continuous at main court.
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance. Protect all devices from ball strikes.
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Principal's Office ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 9'-0" Finishes:
Floor: Carpet, rubber tile or VCT Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Plastic laminate clad; Custom grade; base & cabinets; tall storage cabinet and/or shelves Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 5 CFM / Person + 0.06 CFM/SF Plumbing:
ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 30 FC horiz. @ 30"/15 FC vert. @ 42" Outlets: General Purpose
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: Video, network printer, and data outlets
Security Access: Video Intercom (Ai phone) EQUIPMENT Remarks
Per DoDEA standards
Narrow vision lite
To underside of deck
Provide television and mounting bracket; interactive whiteboard with projector arm; tackboard; markerboard; personal emergency alerting station (PEAS); controls for public address-intercom and monitor for security system.
Minimum 1 duplex outlet for every 10 feet of wall space.
Clock synchronized with the PA/Bell System.
Provide per latest DoDEA Guidance
Refer to IT connection require-ments in IT Connection Matrix in
ROOM NAME: Reading Lab ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 9'-0" Finishes:
Floor: Rubber tile, VCT, or carpet
Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum. blinds or roller shades Doors: Pre-finished solid core wood doors Hardware: InstaKey locking system Millwork: Per DoDEA Guidance Partition Type: Gypsum wallboard over studs Exterior Glazing: Insulated glazing to meet ATFP reqts.
Acoustics: Per DoDEA Guidance, and "Pierce Terrace
Acoustical Requirements" in Appendix D MECHANICAL: Remarks:
Heating: 72°F ± 2°F Air Conditioning: 74°F ± 2°F Ventilation: 10 CFM / Person + 0.12 CFM/SF Plumbing: HW/CW/SK ELECTRICAL: Remarks:
Power: 120 VAC Lighting, FC: 40 FC horiz. @ 30" / 30 FC vert.@ 42" Outlets: Gen. Purpose; Dedicated Interactive Board
Hazardous Area: N/A COMMUNICATIONS: Remarks:
Telephone: Wall mounted phone Public Address: PA, and Clock
Intercom: Intercom button 2-way speakers in center of room.
Data: IWB, video, network printer, wireless and data outlets
CCTV N/A
EQUIPMENT Remarks Provide interactive whiteboard with projection arm; white markerboard and tackboard.
Narrow vision lite
To underside of deck
See A-401. Minimum 1 duplex outlet for every 10 feet of wall space.
Provide per latest DoDEA Guidance
See A-401.
See A-401. Clock synchronized with the PA/Bell System.
See A-401. Refer to IT connection requirements in IT Connection Matrix in DoDEA Ed Spec Special Systems Design Guide (Phases 1 & 2).
ROOM NAME: Staff Collaboration ARCHITECTURAL: Remarks:
Minimum Ceiling Ht. 9'-0" Finishes:
Floor: Rubber tile, VCT or carpet Base: Coved vinyl or rubber base to match flooring Walls: Paint, low VOC, semi-gloss Ceiling: 2x2 white acoustical, lay-in Window Treatment: 1" horizontal alum.