This solicitation is for design-bid-build construction services for Army Family Housing replacement in Baumholder, Germany. The U.S. Army Corps of Engineers, Europe District is seeking to construct a 64-unit replacement housing facility at Smith Barracks and Wetzel Family Housing. The scope of work includes a 12-unit, 3-bedroom apartment building and 42 3-bedroom and 10 4-bedroom townhouses. Ancillary structures such as a power substation, heating plant, and site development features like parking, utilities, landscaping and playgrounds are also required. Drawings can be obtained by emailing the points of contact listed. The purpose of the project is to provide quality housing that meets force protection and energy standards for military personnel and their families stationed in Baumholder.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix B Engineering Studies
PN 93308. FY 22.
Corrected 100% Design Submittal
Project Name: Army Family Housing (AFH)
Replacement Wetzel and Smith Barracks
Location: Baumholder, Germany
Contract number: W912GB19D0006
Task Order Number: W912GB20F0288
January 2023
UNCLASSIFIED // FOR OFFICIAL USE ONLY
Engineering Studies Contract Number: W912GB19D0006
Task Order Number: W912GB20F028
AECOM
UNCLASSIFIED // FOR OFFICIAL USE ONLY
Table of Contents
Site Surveys
Site Plan / Lageplan LP01 (Smith Barracks)
Site Plan / Lageplan LP02 (Wetzel Housing)
Site Plan / Lageplan LP03 (Wetzel Housing)
Hazardous Materials (HAZMAT) Surveys – Transformer Housing Building 8832
HAZMAT Report English
HAZMAT Report German
Geotechnical / Soil investigations
Report
Appendix A Maps with sampling points
Appendix B Boring logs
Appendix C Laboratory reports and sample classification
Site Surveys
PN 93308. FY 22. ENGINEERING STUDIES
100% Design Submittal
Project Name: Army Family Housing (AFH)
Replacement Wetzel and Smith Barracks
Location: Baumholder, Germany
Contract number: W912GB19D0006
Task Order Number: W912GB20F0288
March 2022
Engineering Studies
Contract Number: W912GB19D0006
AECOM
Quality information
Prepared by Checked by Verified by Approved by
Deliverable Originator
Checker
Lead Verifier
Project Manager
AECOM Team Deputy PM / Design Manager
Argelia Tobias Nieto
Almudena Carro Rejas
Brian Goldbach Juan Alonso
Revision History
Revision Revision date Details
00 4/15/2021 35% Design Submission
01 7/16/2021 65% Design Submission
02 01/12/2022 95% Design Submission
03 03/03/2022 100% Design Submission
Signatures
Name Position Date Signature
Almudena Carro Rejas
Argelia Tobias Nieto
Design Manager
Deputy PM
Brian Goldbach Lead Verifier
Juan Alonso Project Manager
Discipline Lead or the person who developed this document
Certified Engineer
(No. of certificate) other
Engineering Studies Contract Number: W912GB19D0006
Page 3 of 7 AECOM
Table of Contents
1. Site Plan / Lageplan LP01 (Smith Barracks)
2. Site Plan / Lageplan LP02 (Wetzel Housing)
3. Site Plan / Lageplan LP03 (Wetzel Housing)
STOP
W
STOP
Tiefbord below ground curbstone
Kastenrinne box gutter
Grünfläche
Bewuchsgrenze / Hecke property boundary / hedge
Nadelbaum needle tree
Verkehrsschild traffic sign
Legende
Hochbord high curbstone
Linien Symbole Text
Zaun fence
Verbundsteinpflaste composite stone paving
Festpunkt fixed point
Gelände- / Aufnahmepunkt landmark
Gebäude building
Einlauf street inlet gutter
Schachtdeckel manhole cover
Schieber (Wasser) valve water
Bewuchsgrenze / Hecke property boundary / hedge
Deckelhöhe cap elevation
Höhenlinien 0,5m hight lines 0,5m
Leistenplatte / Breite 0,30m gutter (width 0,30m)
Mauer wall
Höhenbeschriftung elevation labelling
Böschung slope
Straßenlaterne street lamp
Betonplatten concrete
Absenkstein
Kastenrinne box gutter
Oberflurhydrant pillar hydrant
Höhenlinien 1,0m hight lines 1,0m
Schildpfahl Wasser
Beton concrete
Busch
Laubbaum leaf tree
Rinne gutter
Rinne gutter
Briefkasten
Flachbord flat curbstone
Graben pit
STOP
Tiefbord below ground curbstone
Kastenrinne box gutter
Grünfläche
Bewuchsgrenze / Hecke property boundary / hedge
Nadelbaum needle tree
Verkehrsschild traffic sign
Legende
Hochbord high curbstone
Linien Symbole Text
Zaun fence
Verbundsteinpflaste composite stone paving
Festpunkt fixed point
Gelände- / Aufnahmepunkt landmark
Gebäude building
Einlauf street inlet gutter
Schachtdeckel manhole cover
Schieber (Wasser) valve water
Bewuchsgrenze / Hecke property boundary / hedge
Deckelhöhe cap elevation
Höhenlinien 0,5m hight lines 0,5m
Leistenplatte / Breite 0,30m gutter (width 0,30m)
Mauer wall
Höhenbeschriftung elevation labelling
Böschung slope
Straßenlaterne street lamp
Betonplatten concrete
Absenkstein
Kastenrinne box gutter
Oberflurhydrant pillar hydrant
Höhenlinien 1,0m hight lines 1,0m
Schildpfahl Wasser
Beton concrete
Busch
Laubbaum leaf tree
Rinne gutter
Rinne gutter
Briefkasten
Flachbord flat curbstone
STOP
Tiefbord below ground curbstone
Kastenrinne box gutter
Grünfläche
Bewuchsgrenze / Hecke property boundary / hedge
Nadelbaum needle tree
Verkehrsschild traffic sign
Legende
Hochbord high curbstone
Linien Symbole Text
Zaun fence
Verbundsteinpflaste composite stone paving
Festpunkt fixed point
Gelände- / Aufnahmepunkt landmark
Gebäude building
Einlauf street inlet gutter
Schachtdeckel manhole cover
Schieber (Wasser) valve water
Bewuchsgrenze / Hecke property boundary / hedge
Deckelhöhe cap elevation
Höhenlinien 0,5m hight lines 0,5m
Leistenplatte / Breite 0,30m gutter (width 0,30m)
Mauer wall
Höhenbeschriftung elevation labelling
Böschung slope
Straßenlaterne street lamp
Betonplatten concrete
Absenkstein
Kastenrinne box gutter
Oberflurhydrant pillar hydrant
Höhenlinien 1,0m hight lines 1,0m
Schildpfahl Wasser
Beton concrete
Busch
Laubbaum leaf tree
Rinne gutter
Rinne gutter
Briefkasten
Flachbord flat curbstone
Engineering Studies
Contract Number: XXXXXXXXXXX
Page 7 of 7 AECOM aecom.com
Hazardous Materials (HAZMAT) Surveys
Location: Baumholder, Germany
Building 8832 Hazmat Survey
Location: Baumholder, Germany
Appendices. Calculations
Contract Number: W912GB19D0006
Quality information
Prepared by Checked by Verified by Approved by
Deliverable Originator
Checker
Lead Verifier
Project Manager
Violeta Dimitresku Deputy PM / Design Manager
Argelia Tobias Nieto
Brian Goldbach Juan Alonso
Revision History
Revision Revision date Details
00 4/15/2021 35% Design Submission
01 7/16/2021 65% Design Submission
02 01/12/2022 95% Design Submission
Signatures
Name Position Date Signature
Argelia Tobias Nieto
Brian Goldbach
Michael Ottensmann
Certified Engineer
(No. of certificate) other
Hazmat Survey
FY22
FY22AFH84
Table of Contents
1. Introduction
2. Regulatory Basis
2.1 Asbestos
2.1.1 FGS
2.1.2 Germany and EU
2.2 Artificial Mineral Fibers
2.2.1 FGS
2.2.2 Germany and EU
2.2.3 Classification of AMF for Building Rooms
2.3 PAH – Poly Aromatic Hydrocarbons
2.4 PCB – Polychlorinated Biphenyl
2.5 Lead Paint
2.5.1 FGS
2.5.2 Germany
3. HAZMAT Survey
4. Results
4.1 General building description
4.2 Survey results
4.2.1 Asbestos
4.2.2 Artificial Mineral Fibers (AMF)
4.2.3 Polycyclic aromatic hydrocarbons (PAH)
4.2.4 Polychlorinated biphenyl (PCB)
4.2.5 Heavy Metals
4.2.6 Other Materials
5. Conclusions and Recommendations
6. Waste Codes
7. References
8. Limitations
APPENDICES
Appendix A Floorplans and Sample Points
Appendix B Photo Documentation
Appendix C Laboratory Results
Figures
Figure 1: Building 8832
Tables
Table 1. KI-Index Classification Table 2. Relevant Threshold Values for Classification as Hazardous Wastes Table 3. Results Asbestos Table 4. Results PAH Table 5. Results Heavy Metals Table 6. Results HBCD Table 7. Results LAGA Table 8. Conclusions and Recommendations Table 9. Waste Codes (AVV)
List of Acronyms: Abbreviations, acronyms and translation acc. according
ACM Asbestos-Containing Material
AMF artificial mineral fibers
AVV Abfallverzeichnis-Verordnung (Waste Catalogue Regulation)
Bdl. below detection level
BH Baumholder
Bldg. building
DGUV Deutsche Gesetzliche Unfallversicherung e. V. (German Social Accident Insurance)
DIN Deutsches Institut für Normierung (German Institute for Standardization)
DoD Department of Defense
DRM demolition, renovation, maintenance
EN European Standard
EU European Union
FGS Final Governing Standards
GefStoffV Gefahrstoffverordnung (Hazardous Substances Ordinance)
HAZMAT hazardous materials
HM heavy metal
ISO International Organization for Standardization
KI carcinogenicity index
MMMF Man-made mineral fibers
NH (fuse) Niederspannungs- Hochleistungssicherung (low-voltage - high-power fuse)
OEL Occupational Exposure Limits
PAK (PAH) Polycyclische aromatische Kohlenwasserstoffe
(polycyclic aromatic hydrocarbons)
PCB Polychlorinated Biphenyls
PSF Plaster, putty/filler and floor tile mastic ppm parts per million
RAL Deutsches Institut für Gütesicherung und Kennzeichnung e. V. (Reichs-Ausschuss für
Lieferbedingungen) German Institute for Quality Assurance and Labeling
TR Technische Regeln (Technical Regulations)
TRGS Technische Regeln für Gefahrstoffe (Technical Regulation for Hazardous Materials
U.S. United States
USACE U.S. Army Corps of Engineers, Europe District
WHO world health organization
FCKW Fluorchlorkohlenwasserstoffe, HFCKW Teilhalogenierte Fluorkohlenwasserstoffe
1. Introduction
AECOM was contracted by USACE to document the demolition of building 8832, located within Wetzel in Baumholder, Germany. As a part of this effort, AECOM was contracted to complete a hazardous materials (HAZMAT) survey to ensure that the demolition adequately protects the workers and to ensure that wastes are properly disposed of.
2. Regulatory Basis
2.1 Asbestos
2.1.1 FGS
The FGS Germany (2017) is the guiding document governing environmental matters for the US DoD in
Germany. The FGS provides three definitions that are relevant to the assessment of asbestos for this project:
Asbestos: Generic term used to describe six distinctive varieties of fibrous mineral silicates, including chrysotile, amosite, crocidolite, tremolite asbestos, anthophyllite asbestos, actinolite asbestos, and any other of these materials that has been chemically treated and/or altered.
Asbestos-Containing Material (ACM): Any material containing >1% asbestos by weight.
Friable Asbestos: Any material containing >1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Occupational health requirements are not directly defined in the FGS. The FGS does require a notification and education program to tell workers, tenants, and building occupants where potentially friable ACM is located, and how and why to avoid disturbing the ACM. The FGS also requires that before disturbing or demolishing a facility or part of a facility, installations will remove all regulated ACM.
2.1.2 Germany and EU
In accordance with Technical Regulation for Hazardous Materials No. 519 Asbestos Demolition, reconstruction or maintenance work (TRGS 519, 2014, last amended 2019 /2./ materials are considered asbestos-containing when they contain one of the following silicates with fibrous structure: Actinolite, amosite, anthophyllite, chrysotile, crocidolite, tremolite. Asbestos-containing materials are to be separated under demolition, renovation or maintenance as defined under the special labor protection measures in accordance with the provisions of the Hazardous Substances Ordinance (GefStoffV) of
2010, last amended 2017 /8./ and TRGS 519 and disposed of properly. The scope of the required occupational safety measures depends on the type of asbestos product. In particular, it is important to distinguish between weakly bound (density less than 1,000 kg / m³) and tightly bound (density greater than 1,400 kg / m³) asbestos products. According to the TRGS, a risk assessment is required when working on asbestos-containing products.
Article 2(8) of the Hazardous Substances Ordinance (GefStoffV) /8./ defines occupational exposure limits (OEL) as the limit value for the time-weighted average concentration of a substance in the air at the workplace with respect to a given reference period. This OEL indicates the concentration of a substance at which acute or chronic adverse effects on the health of employees are generally not to be expected /7./. No OEL is currently defined for the majority of carcinogenic substances and none should be derived. The Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work, last amended on 26 July 2019 /15./, provides minimum requirements for assessing the risks to the health and safety of worker arising, or likely to arise, from the effects of chemical agents that are present at the workplace or as a result of any work activity involving chemical agents. In accordance with Article 8 of Directive 2009/148/EC of 30
November 2009 on the protection of workers against exposure to asbestos at work, last amended on
26 July 2019 /16./, employers shall ensure that no worker is exposed to an airborne concentration of asbestos in excess of 0.1 fibres/cm3 as an 8-hour time-weighted average (TWA).
In general, Annex II of the GefStoffV /8./ provides a ban on work on asbestos-containing parts. Only demolition, renovation, maintenance work (DRM-work) and activities with metrological monitoring are allowed. The associated expenses incurred in working with materials containing asbestos including waste disposal must also be accounted for. DRM work on asbestos-containing materials must be reported to the competent national health and safety authority at least 7 days before starting work.
2.2 Artificial Mineral Fibers
2.2.1 FGS
The FGS Germany (2017) does not address existing AMF. The US Occupational Safety and Health
Administration presently consider that “there is insufficient evidence that synthetic mineral fibers cause respiratory disease in humans. Results from animal experiments have led to conservative classifications of certain synthetic mineral fibers as possible human carcinogens. Specifically, insulation glass wool, continuous glass filament, rock (stone) wool, and slag wool are not classifiable as to their carcinogenicity to humans.”
(Source: https://www.osha.gov/SLTC/syntheticmineralfibers/health.html)
2.2.2 Germany and EU
Demolition, reconstruction and maintenance work concerning artificial mineral fibers (AMF) in Germany are regulated by TRGS 521 (demolition, renovation and maintenance work with old mineral wool) of
2008, not amended since publication /3./. For purposes of this regulation, "old" mineral wool is defined as being manufactured prior to 1996. A production and use ban for these products based on the
Hazardous Substances Act with implemented in 2000. In the years between 1996 and 2000, both "old" and "new" products were produced and used.
A carcinogenic potential is to be assumed for AMF products unless the manufacturer or user proves a different classification. This applies, for example, to the planned building removal of all not otherwise classified AMF products and commonly used as insulating materials, which were built before the year
1996. Due to lack of product data on some materials in the building, any unanalyzed AMF substances should be treated as carcinogenic. Where the RAL Certification Seal of the purchased material is available, this provides sufficient evidence of non-carcinogenic.
The future removal of the insulation during building demolition works must be carried out in accordance with the provisions of TRGS 521 /3./. In particular, the mineral fiber products are to be removed using low-dust methods and limit possible destructive break down AMF. The AMF must be disposed of separately from other waste. Measures must be taken to avoid the release of carcinogenic fiber dusts during storage and transportation. Waste, scrap and loose packages are to be collected and placed in appropriate containers (for example tear-resistant and dustproof bags) and labeled with the words
"content may release carcinogenic fiber dusts".
The Hazardous Materials Ordinance (GefStoffV) /8./ defines a carcinogenicity index (KI), for glass WHO fibers. The KI is a dimensionless quantity and is determined by the material composition of the analyzed mineral fibers in the insulation (or other) sample. It is calculated as the sum of the mass percentages
(in M %) of Sodium Oxide (Na2O), Potassium Oxide (K2O), Calcium Oxide (CaO), Magnesium Oxide
(MgO), Barium Oxide (BaO) and Barium Trioxide (B2O3) minus the double mass content of Aluminum
Oxide (Al2O3).
According to the GefStoffV /8./, glass WHO fibers, including the man-made mineral fibers (AMF), are classified with a KI as presented in Table 1:
Table 1. KI-Index Classification
Category Definition
KI < 30 – Category 1B Substances listed in Category 1B should be considered as carcinogenic to humans.
KI > 30 and < 40 – Category 2 Category 2 substances are materials of concern because of possible carcinogenic effect in humans.
KI > 40 – Category 3 Classified as non- carcinogenic
2.2.3 Classification of AMF for Building Rooms
In accordance with the above regulation, it is recommended for the building rooms that where RAL certification for the insulation material installed is provided or it is demonstrated that the material was installed after 2000, the material is considered non-cancer causing. In the absence of certification to the contrary, any material having a KI index result showing a “cancer-causing” designation will be considered “cancer-causing” and should be abated during the next renovation/demolition work in the associated room.
2.3 PAH – Poly Aromatic Hydrocarbons
Polycyclic aromatic hydrocarbons (PAHs) comprise a large group of compounds that consist of fused aromatic rings. Work in which workers are exposed to PAHs are to be classified as carcinogenic when a level of 50 mg/kg dry weight benzo(a)pyrene (lead compound) in accordance with §3(3) of the
Hazardous Substance Ordinance (GefStoffV) /8./Error! Reference source not found. in connection w ith TRGS 905 “Table of carcinogens” /6./ of 2016, last amended 2020 is observed.
In relation to work involving PAH-containing substances, this means that these operations take place in contaminated areas. The rules of the DGUV-R-101-004 (former BRG 128: Work in contaminated areas) of 1997, last amended 2006 and renamed 2015 /7./ apply. The release of dust when handling and decommissioning of PAH-containing or tar-containing materials must be prevented. The TRGS 551
("Tar and other pyrolysis of organic material") of 2015, last amended 2016 /5./ provides additional instructions for handling tar materials during the course of demolition and remediation measures.
Threshold limits for hazardous waste in Rheinland-Pfalz /25./: PAH > 1,000 mg/kg, Benzo(a)pyrene >
50 mg/kg.
2.4 PCB – Polychlorinated Biphenyl
The so-called PCB directive on the evaluation and remediation of PCB-contaminated construction materials in buildings of 1994 /14./ is currently being used to evaluate the remediation priority of PCB-containing components in buildings. The PCB Directive defines intervention values used in the context of construction safety law. The Directive contains standards for indoor air concentrations, remediation priority, rehabilitation implementation, disposal of PCBs and other aspects of dealing with PCB-contaminated construction products in buildings.
Guidelines have been prepared and put in place in several German states for the evaluation and remediation of PCB loads in buildings. The PCB contents in the buildings were assessed according to the PCB Guideline of Rheinland-Pfalz (PCB-Richtlinie des Landes Rheinland-Pfalz). Under these guidelines, substances with PCB levels above 0.1 mass% (1,000 mg/kg) are a potential primary source of PCB emission. Primary sources are products, which PCB were deliberately added to alter the product properties. Secondary sources are items in indoor air in which PCBs were released over a longer period from the primary sources. The detected PCB can also be issued from secondary sources over a longer period of time.
The "Regulation on the disposal of polychlorinated biphenyls, polychlorinated terphenyls and halogenated Monomethyldiphenylmethane" (PCBAbfallV) of 2000, last amended 2012 /13./ in conjunction with the European POP Regulation ("Regulation No. 2019/1021 of European-Parliament and the Council of 20. June 2019 on persistent organic pollutants"), last amended 2020 /17./ regulate the disposal of waste containing more than 50 mg/kg PCB.
PCB-containing paints or components require special work methods and safety measures. Dealing with the PCB-contaminated materials paints is classified as work in contaminated areas according to
DGUV-R101-004 and performed with the corresponding OSH regulations. This work should be defined in health and safety plan in accordance with DGUV-R-101-004 (former BRG 128: Work in contaminated areas) /7./ by the contracted entity.
2.5 Lead Paint
2.5.1 FGS
The applicability of the FGS is limited to child-occupied facilities as defined as Child-Occupied Facility:
A facility, or portion of a facility, visited regularly by the same child, 6 years of age or under, on at least
2 different days within any week, provided that each day’s visit lasts at least 3 hours and the combined weekly visits last at least 6 hours, and the combined annual visits last at least 60 hours. Child-occupied facilities may include but are not limited to daycare centers, preschools, playgrounds, and kindergarten classrooms. The buildings under this contract are considered a child-occupied facility.
Additional guidance to protect personnel from lead exposure is found under DODI 6055.1, “DOD Safety and Occupational Health (SOH) Program,” DODI 6055.05, “Occupational and Environmental Health
(OEH),” and concomitant Service instructions.
2.5.2 Germany
Lead-containing paint as well as lead containing material are regulated under the CLP Ordinance /25./ in Germany. According to Appendix VI, Table 3 of the CLP Ordinance, a building material is classified as lead containing when the lead concentration exceeds 0.03 mass% (300 mg/kg). Work on such building material shall be conducted in accordance with TRGS 505 “Lead” of 2007 /1./. Specifically, the technical regulations of TRGS 505 are to be observed when handling lead-containing materials. In addition, the workplace safety regulations of the DGUV-R-101-004 /7./ for work in contaminated areas must also be observed when working on components containing harmful substances. Additional information regarding workplace safety when handling heavy metal containing materials are presented in the TRGS 900 “Workplace Threshold Values” /22./ and TRGS 910 “Hazard based Action Plan for
Occupational Exposure to Carcinogenic Substances” (such as arsenic, cadmium and chromium VI)
/28./.
If construction material has to be removed and disposed of as waste, it has to be classified as hazardous wastes when the concentrations exceed the thresholds presented in Table 2 according to the Technical
Guidelines for Classifying Wastes according to their Hazards (Technische Hinweise zur Einstufung von
Abfällen nach ihrer Gefährlichkeit /26./) of the State Working Group Waste (Länder Arbeitsgemeinschaft
Abfall LAGA), of 9th February 2021. For heavy metals not included in this LAGA Guidelines such as mercury and total chromium, the state relevant regulations of Rheinland-Pfalz pertaining to classification of construction materials for disposal or reuse apply /25./.
Table 2. Relevant Threshold Values for Classification as Hazardous Wastes
Heavy Metal Threshold Values [mg/kg] /24./
Arsenic 1000
Lead 2500
Cadmium 1000
Chromium Total 6001)
Copper 2500
Nickel 1000
Mercury 51)
Zinc 2500 1)) Classification of hazardous wastes in Rheinland-Pfalz according to the Guidelines for Construction Wastes of May 2007 and
Appendix XIV of 12. October 2009 at https://kreislaufwirtschaft-bau.rlp.de/de/service/downloads/leitfaden-bauabfaelle/, /26./ https://kreislaufwirtschaft-bau.rlp.de/de/service/downloads/leitfaden-bauabfaelle/
3. HAZMAT Survey
The HAZMAT survey in building 8832 took place on 2nd November 2020. Building 8832 is a high voltage transformer building and an escort was required during the survey. The building has a simple structure and all relevant areas in the building were freely accessible. The building inspections and sampling were performed by experienced AECOM staff.
During the survey, 17 samples were taken and analyzed for their contaminant concentration. Analysis for Asbestos (4) was undertaken by the accredited laboratory Competenza GmbH. The analysis for
Heavy Metals (7), PAH (2), HBCD (2) and LAGA Debris (2) was undertaken by the accredited laboratory
Eurofins Umwelt West GmbH. A summary of the sampling results is provided in Chapter 4 below.
The sampling points were photographically documented and are presented in the floor plans in
Appendix A and additionally in a photo documentation Appendix B.
It is essential to note that a HAZMAT survey is, by its very nature, not exhaustive and minimally destructive. Building materials of similar construction and age are assumed to be made of the same material. Therefore, for purposes of this survey, if a sample returns a “positive” result, it is assumed that all materials (such as flooring, for example) of a similar nature are contaminated. Conversely, where the results show “negative” results, this is assumed to apply to all materials of a similar nature and age. Because the survey is not exhaustive, it is possible that areas not sampled because of their similarity to the areas sampled may have had different HAZMAT results, had they been sampled. A good example of this is mastic adhesive under carpeting. During a renovation project, the old mastic might not have been completely removed, but this would only become apparent if all the carpet were lifted during the HAZMAT survey. Thus, some asbestos-containing mastic might still remain undetected.
The laboratory reports for the current analysis are listed in Appendix C.
4. Results
4.1 General building description
Building 8832 is currently a high voltage electrical transformer building. It is a small structurally simple building that consists of concrete slab, concrete load bearing walls as well as concrete interior division walls.
The building has a flat roof covered with a tar looking paper. The outside doors are fire - rated doors.
The door frames are predominantly made from metal. The building does not have any window; several ventilation grids were installed on the roof as well as above the main door instead.
4.2 Survey results
The results of the laboratory analysis, as well as the results of the visual inspections, are shown in the following chapters separated according to the pollutant type.
In addition to the previously mentioned building containments, the presence of the following contaminated building materials or installations can’t be excluded:
- NH fuses in the electrical installations (or corresponding stocks) can be asbestos-containing.
As a HAZMAT survey is, by its very nature, not exhaustive and minimally destructive, it is possible that contaminant-containing materials exist in inaccessible building parts. If potentially contaminant-containing materials are found during the demolition work, current regulations must be checked whether they can be removed and disposed in accordance to current health and safety guidelines or if they can remain in the building.
Figure 1: Building 8832
4.2.1 Asbestos
The asbestos survey was carried out in accordance with the TRGS 519. Four samples were collected during this HAZMAT Survey and analyzed for asbestos fibers. The result of the survey regarding asbestos containing building material is presented in Table 3 below. The detection limit of all samples was 0.001%. For sample locations and photos, see Appendix A and B, respectively.
Table 3. Results Asbestos
Sample Nr.
Date
Sampling Sampling location
Product Result
BH84-8832-AS1 02.11.2020 Ground Floor Mortar Filler No asbestos detected
BH84-8832-AS2 02.11.2020 Ground Floor Inner wall plaster No asbestos detected
BH84-8832-AS3 02.11.2020 Ground Floor Outer wall plaster No asbestos detected
Not sampled 02.11.2020 Ground Floor Fire door Asbestos suspected
BH84-8832-AS4 27.08.2021 Roof Tar paper No asbestos detected
Font "bold" printed: proof or suspicion of the pollutant
According to the analytical results, asbestos was not identified in the sampled building materials.
However, the presence of asbestos is suspected in the fire door, manufactured prior 1990, at the main access to the building. It is also possible that the tar paper on the roof contains asbestos.
4.2.2 Artificial Mineral Fibers (AMF)
No samples were collected and analyzed for AMF in the course of the survey conducted on 2nd
November 2020.
As a HAZMAT survey is not exhaustive and minimally destructive, it is possible that AMF-containing materials exist in inaccessible building parts. In this case, examples would be insulating materials in the area of door connections or windows. If potentially AMF-containing materials are found during the demolition work, they should be considered “old” mineral wool if the manufacturing year can’t be determined.
4.2.3 Polycyclic aromatic hydrocarbons (PAH)
A tar paper layer was observed at the flat roof of the building and two samples were collected and analyzed for PAH (BH84-8832-PAH-1 and PAH-2) results of which are presented in Table 4.
In addition, as a HAZMAT survey is not exhaustive and minimally destructive, it is possible that PAH-containing materials with a Benzo(a)pyrene content above 50 mg/kg exist in inaccessible building parts.
Threshold limits for hazardous waste: PAH > 1,000 mg/kg, Benzo(a)pyrene > 50 mg/kg.
Table 4. Results PAH
Sample Nr. Date Sampling Sampling location
Product PAH/Benzo(a)pyren
[mg/kg]
BH84-8832-PAH-1 27.08.2021 Roof Tar paper 21.4/1.9
BH84-8832-PAH-2 27.08.2021 Roof Tar paper 207/38
4.2.4 Polychlorinated biphenyl (PCB)
No sample was collected and analyzed for PCB in the course of the survey conducted on 2nd November
2020.
At the time of the HAZMAT Survey, a total of three transformer units were observed in building 8832.
Two of these electrical devices contain PCB oils. Redundant transformers containing PCB shall be removed from the site as complete load, i.e. together with the oil content to be transferred to a specialized site where the extraction of the PCB oil can be undertaken safely.
Products are considered PCB-containing if they contain at least 50 mg/kg of PCB.
4.2.5 Heavy Metals
As part of the building survey on 2nd November 2020 seven paint samples were collected from wall, floor and door and analyzed for heavy metals. The results of the laboratory analysis are presented
Table 5.
Table 5. Results Heavy Metals
Sample Nr. Date Sampling Sampling location
Product Heavy metals
[mg/kg]
BH84-8832-HM1 02.11.2020 Ground Floor Wall Paint Lead 5
Zinc 86
BH84-8832-HM2 02.11.2020 Ground Floor Wall color Lead 7
Zinc 174
BH84-8832-HM3 02.11.2020 Ground Floor Floor color Lead 517
Zinc 11,100
BH84-8832-HM4 02.11.2020 Ground Floor Wall Paint Lead 6
Zinc 55
BH84-8832-HM5 02.11.2020 Ground Floor Wall Paint Lead 17
Zinc 31,200
BH84-8832-HM6 02.11.2020 Ground Floor Door wall Paint Lead 3,180
Zinc 7,820
BH84-8832-HM7 02.11.2020 Ground Floor Exterior wall
Paint
Lead 790
Zinc 130
Font "bold" printed: proof or suspicion of the pollutant
Three samples of floor, wall and door paint presented lead concentrations exceeding the threshold values of 300 mg/kg defined by the CLP Ordinance /25./ for lead and two of these samples also presented zinc concentrations exceeding the threshold values for hazardous wastes as presented in
Table 2.
4.2.6 Other Materials
Hexabromocyclododecane (HBCD), FCKW (Fluorchlorkohlenwasserstoffe), HFCKW (teilhalogenierte
Fluorkohlenwasserstoffe) can potentially be found in form of polystyrene sheets. In the course of the survey, this type of material was identified at an inner wall as Styrofoam and sampled. Mineral
Construction Material on the wall and floor slab of the building was collected to be analysed for LAGA
Debris. The results of the laboratory analysis are presented in Table 6 and 7.
Table 6. Results HBCD
Sample Nr. Date Sampling Sampling location
Product
HBCD
[mg/kg]
BH84-8832-HBCD1 02.11.2020 Ground Floor Wall filling material No HBCD detected
BH84-8832-HBCD2 02.11.2020 Ground Floor Wall filling material No HBCD detected
According to the analytical results, the HBCD concentrations in the analyzed samples was below the analytical detection limits-
Table 7. Results LAGA
Sample Nr. Date Sampling Sampling location
Product
LAGA
Results
BH84-8832-LAGA-1 22.10.2021 Ground Floor Floor Appendix C
BH84-8832-LAGA-2 27.08.2021 Ground Floor Wall Appendix C
5. Conclusions and Recommendations
PCB and heavy metals were the primary contaminant identified in the HAZMAT survey at Building 8832.
Table 8 shows a brief description of the conclusions and recommendations of the found contaminants.
Working in contaminated areas are to be carried out in accordance with DGUV-Rule 101-004 and protective measures according to TRGS 524.
Table 8. Conclusions and Recommendations
Contaminant Product /
Suspect
Place of discovery Result Recommendations
Asbestos plaster, cement, etc.
Mortar and plaster on windows, walls, doors etc.
No asbestos detected No asbestos identified
Fire doors, tar paper
Assumed to be asbestos containing
Work according TRGS 519;
Disposal as hazardous waste.
AMF insulation Insulation No AMF detected No AMF identified
PAH
glue, joint material, etc.
layer, joints etc. No PAH detected No PAH identified
Tar paper roof No PAH detected
Work according TRGS
551; Disposal as hazardous waste
Heavy
Metals Wall paint -
Heavy metal concentrations above threshold values for hazardous wastes and CLP Ordinance for lead
Work according TRGS 505;
Disposal as hazardous waste. Removal including separation in accordance with work protection regulations
HBCD Styrofoam Inner wall No HBCD detected No HBCD identified
LAGA
Mineral
Construction
Material
Wall and Floor slab
Results for Mineral
Waste do not exceed
LAGA Z2
Results for Mineral Waste do not exceed LAGA Z2
PCB
old fluorescent lamps cannot be excluded:
classified as
PCB-containing
Disposal as hazardous waste old fluorescent lamps
Asbestos
A total of 4 samples of plaster, mortar and tar paper from the flat roof were collected by AECOM at
Building 8832 in 2021. None of the samples revealed the presence of asbestos.
The potential asbestos containing fire door was not sampled, to keep destruction to a minimum, but is classified as asbestos-containing because of the building year of the building (before 1990). It is also possible that the tar paper on the roof contains asbestos. As asbestos-containing components in the above-mentioned materials cannot be excluded, employed personnel or other persons requiring protection should not be put at risk by hazards and should be reduced to a minimum during the dismantling work of the contaminated materials.
A common procedure for removal of asbestos-containing fire door is to remove the flange in one piece, seal it and transport it to a black zone (often outside of the construction site, e.g. to a place of the remediation company). There the asbestos-containing materials can be removed.
The occupational safety measures are included in the “regulations for safety and health protection when working in contaminated areas” (DGUV-R-101-004) and the technical rules regarding protective measures for activities related to asbestos containing material are presented in the TRGS 519 /2./.
If asbestos-containing products are encountered in non-accessible areas during the renovation, the requirements of the TRGS 519 (guideline for works with asbestos products) apply.
AMF
No samples were collected and analyzed for AMF.
As a HAZMAT survey is not exhaustive and minimally destructive, it is possible that AMF-containing materials exist in inaccessible building parts. In this case, examples would be insulating materials in the area of door connections or windows, between walls of dry wall, or sound impact insulation under screed or insulation on the exterior façade. If potentially AMF-containing materials are found during the demolition work, they should be considered “old” mineral wool if the manufacturing year cannot be determined.
If it is necessary during the renovation process, the future removal of the insulation must be carried out in accordance with the provisions of TRGS 521 (/3./) In particular, the mineral fiber products are to be removed using low-dust methods and limit possible destructive break down of AMF.
Heavy Metals
Seven samples of wall paint were collected and analyzed for heavy metals. Three samples presented lead concentrations above the threshold values defined by the CLP Ordinance for lead /27./. In addition, one samples revealed elevated zinc concentrations above the threshold values for hazardous wastes according to Table 2. The guidelines and relevant statutes for lead are found in chapter Error! Reference s ource not found..
Working with components that might contain lead as part of the demolition shall be considered as work with Hazardous Materials in accordance with TRGS 505 and the work must be carried out in accordance with the provisions of TRGS 505 (/1./), TRGS 524 (/4./) and DGUV 101 004 (/7./)).
PCB
Two samples were collected by WPW and analyzed for PCB. No PCB concentrations above analytical detection limits were identified. Therefore, no PCB containing material was identified at Building 8832.
PAH
Two Samples were collected from the Tar paper on the flat roof of the building and analyzed for PAH.
However, the results of both samples do not exceed the threshold limits for hazardous waste.
In general, work with PAH-containing materials must be carried out in accordance with the provisions of TRGS 524 (/4./), DGUV-R 101-004 (/7./) and TRGS 551 (/5./), if threshold limits for hazardous waste
(PAH > 1,000 mg/kg, Benzo(a)pyrene > 50 mg/kg) are encountered during demolition work.
HBCD
Styrofoam was identified at an inner wall of Building 8832; two samples were collected and analyzed.
The HBCD concentrations were below detection limit. Therefore, no HBCD containing material was identified at Building 8832.
LAGA
Two samples were collected from mineral construction materials from wall and floor slab. Results are presented in Appendix C.
6. Waste Codes
Table 9 shows contaminant-containing building materials, that can be expected in a dismantling measure, with the corresponding waste codes according to the German Abfallverzeichnis-Verordnung
(AVV /18./).
Waste codes marked with a "*" is always considered hazardous waste in the sense of the German AVV.
The disposal must always be documented in accordance with the German Nachweisverordnung
(NachwV /21./, Ordinance on Waste Disposal and Recovery Records).
Table 9. Waste Codes (AVV)
Contaminant Waste or
Component
AVV
(Waste
Codes)
Waste according to
AVV
Annotation
Asbestos
Gaskets, NH-fuses, fire doors
17 06 05* building materials containing asbestos hazardous waste
AMF Roof insulation 17 06 03*
Insulation material that consists of or contains dangerous substances hazardous waste
PAH
PAH-containing moisture barriers
17 03 10* /
17 03 03*
Bituminous mixtures, coal tar and tar-containing product hazardous waste
PCB-containing ballasts old fluorescent lamps 16 02 09*
Transformers and capacitors that contain PCB hazardous waste
HBCD, FCKW,
HFCKW
polystyrene sheets 17 06 03*
Insulation material that consists of or contains dangerous substances hazardous waste
7. References
/1./ TRGS 505: Technische Regeln für Gefahrstoffe „Blei“, Februar 2007
/2./ TRGS 519: Technische Regeln für Gefahrstoffe „Asbest: Abbruch-, Sanierungs- oder
Instandhaltungsarbeiten“, Januar 2014, zuletzt geändert und ergänzt: GMBl 2019 S. 786-798 v.
17.10.2019 [Nr. 40]
/3./ TRGS 521: Technische Regeln für Gefahrstoffe: Abbruch-, Sanierungs- und
Instandhaltungsarbeiten mit alter Mineralwolle (Ausgabe Februar 2008)
/4./ TRGS 524: Technische Regeln für Gefahrstoffe: Schutzmaßnahmen bei Tätigkeiten in kontaminierten Bereichen (Ausgabe Februar 2010, zuletzt geändert und ergänzt: GMBI 2011 S.
1018-1019 [Nr. 49-51]
/5./ TRGS 551: Technische Regeln für Gefahrstoffe: Teer und andere Pyrolyseprodukte aus organischem Material, Ausgabe August 2015, zuletzt geändert und ergänzt: GBMI 206 S. 8-10 [Nr.
1] vom 27. Januar 2016
/6./ TRGS 905: Technische Regeln für Gefahrstoffe: Verzeichnis krebserzeugender, erbgutverändernder oder fortpflanzungsgefährdender Stoffe (Ausgabe März 2016, zuletzt geändert und ergänzt: GMBl 2020, S. 201 [Nr. 9-10] vom 13.03.2020
/7./ Deutsche Gesetzliche Unfallversicherung – DGUV-Regel 101-004, Kontaminierte Bereiche, Ausgabe April 1997, zuletzt geändert Februar 2006 (ehemals BGR 128: Arbeiten in kontaminierten Bereichen, umbenannt in 2015)
/8./ Verordnung zum Schutz von Gefahrstoffen (Gefahrstoffverordnung – GefStoffV) von 26
November 2010 (BGI. I S.1643, 1644), zuletzt geändert durch Artikel 148 des Gesetzes vom 29.
März 2017 (BGBI. I S. 626)
/9./ Landesamt für Arbeitsschutz, Gesundheitsschutz und technische Sicherheit, Berlin 82: Auflage, September 2008: Handlungsanleitung für den Umgang mit teerhaltigen Materialien im Hochbau –
PAK Handlungsanleitung
/10./ Richtlinie für die Bewertung und Sanierung schwach gebundener Asbestprodukte in Gebäuden
(Asbest-Richtlinie) Fassung Januar 1996, (Mitteilungen Deutsches Institut für Bautechnik 1996
Nr. 3, Seite 88)
/11./ Verordnung über Verbote und Beschränkungen des Inverkehrbringens und über die Abgabe bestimmter Stoffe, Gemische und Erzeugnisse nach dem Chemikaliengesetz (Chemikalien-
Verbotsverordnung - ChemVerbotsV), 18. Juli 2017, zuletzt geändert durch Artikel 300 der
Verordnung vom 19. Juni 2020 (BGBl. I S. 1328)
/12./ Verordnung über Anforderungen an die Verwertung und Beseitigung von Altholz
(Altholzverordnung –AltholzV) vom 15. August 2002 (BGBI. I S. 3302), zuletzt geändert zuletzt geändert durch Artikel 120 der Verordnung vom 19. Juni 2020 (BGBI. I, S. 1328).
/13./ Verordnung über die Entsorgung polychlorierter Biphenyle, polychlorierter Terphenyle und halogenierter Monomethyldiphenylmethane (PCB/PCT-Abfallverordnung – PCBAbfallV), vom 26.
Juni 2000, zuletzt geändert durch Artikel 5 Absatz 21 des Gesetzes vom 24. Februar 2012 (BGBI
I S. 212)
/14./ Richtlinie für die Bewertung und Sanierung PCB-belasteter Baustoffe und Bauteile in Gebäuden
(PCB-Richtlinie) der Fachkommission Baunormung der Arbeitsgemeinschaft der für das Bau-, Wohnungs- und Siedlungswesen zuständigen Minister der Länder (ARGEBAU) – Fassung
September 1994
/15./ Richtlinie 98/24/EG vom 7. April 1998 zum Schutz von Gesundheit und Sicherheit der
Arbeitnehmer vor der Gefährdung durch chemische Arbeitsstoffe bei der Arbeit, zuletzt geändert am 26. Juli 2019
/16./ Richtlinie 2009/148/EG vom 30. November 2009 über den Schutz der Arbeitnehmer gegen
Gefährdung durch Asbest am Arbeitsplatz, zuletzt geändert am 26. Juli 2019
/17./ Verordnung (EU) 2019/1021 des Europäischen Parlaments und des Rates vom 20. Juni 2019 über persistente organische Schadstoffe (POP-Verordnung), zuletzt geändert am 8. April 2020
/18./ Verordnung über das Europäische Abfallverzeichnis (Abfallverzeichnis-Verordnung – AVV) vom
10. Dezember 2001, BGBI. I, S.3379, zuletzt geändert durch Artikel 1 der Verordnung vom 30.
Juni 2020 (BGBI. I S. 3005)
/19./ Gesetz zur Förderung der Kreislaufwirtschaft und Sicherung der umweltverträglichen
Bewirtschaftung von Abfällen (Kreislaufwirtschaftsgesetz – KrWG) vom 24.02.2012 (BGBI I S.
212), das zuletzt geändert durch Artikel 2 Absatz 9 des Gesetzes vom 20. Juli 2017 (BGBI. I S.
2808).
/20./ Mitteilung der Länderarbeitsgemeinschaft Abfall (LAGA) 20 – Anforderungen an die stoffliche
Verwertung von mineralischen Reststoffen/Abfällen – Technische Regeln, November 2003 und
Vorwort von Dezember 2012
/21./ NachwV (Nachweisverordnung) - Verordnung über die Nachweisführung bei der Entsorgung von
Abfällen, Ausgabe Oktober 2006, letzte Änderung 29. Oktober 2020
/22./ TRGS 900 Technische Regeln für Gefahrstoffe „Arbeitsplatzgrenzwerte“, Ausgabe Januar 2006, zuletzt geändert GMBI 2021, S. 580 (Nr. 25) am 23. April 2021
/23./ Verordnung (EG) Nr. 1272/2008 des europäischen Parlaments und des Rates vom 16. Dezember
2008 über die Einstufung, Kennzeichnung und Verpackung von Stoffen und Gemischen, zur
Änderung und Aufhebung der Richtlinien 67/548/EWG und 1999/45/EG und zur Änderung der
Verordnung (EG) Nr. 1907/2006, zuletzt geändert am 3. Februar 2021
/24./ Technische Hinweise zur Einstufung von Abfällen nach Ihrer Gefährlichkeit, Bund/Länder-
Arbeitsgemeinschaft Abfall (LAGA) vom 9. Februar 2021
/25./ Rundschreiben des Ministeriums für Umwelt, Ernährung, Energie und Forsten (MUEEF)
Rheinland-Pfalz an SAM Sonderabfall-Management-Gesellschaft Rheinland-Pfalz mbH, Landesamt für Umwelt. Struktur- und Genehmigungsdirektion Nord/Süd zur Anwendung der
Technischen Hinweise der LAGA zur Einstufung von Abfällen nach ihrer Gefährlichkeit vom 16.
Juli 2019
/26./ Leitfaden Bauabfälle des Ministeriums für Umwelt, Ernährung, Energie und Forsten (MUEEF)
Rheinland-Pfalz
(https://kreislaufwirtschaft-bau.rlp.de/de/service/downloads/leitfaden-bauabfaelle/)
/27./ Verordnung (EG) Nr. 1272/2008 des Europäischen Parlaments und des Rates vom 16.
Dezember 2008 über die Einstufung, Kennzeichnung und Verpackung von Stoffen und
Gemischen, zur Änderung und Aufhebung der Richtlinien 67/548/EWG und 1999/45/EG und zur
Änderung der Verordnung (EG) Nr. 1907/2006 - CLP- oder GHS-Verordnung, zuletzt geändert am 20. April 2021.
/28./ TRGS 910 Risikobezogenes Maßnahmenkonzept für Tätigkeiten mit krebserzeugenden
Gefahrstoffen, Februar 2014, zuletzt geändert Februar 2021 https://kreislaufwirtschaft-bau.rlp.de/de/service/downloads/leitfaden-bauabfaelle/
8. Limitations
AECOM has prepared this report for the sole use of USACE and USAG Baumholder in accordance with the Agreement dated 10 Sept 2020 under which our services were performed.
No warranty, expressed or implied, other than expressed in the Agreement, is made as to the professional advice included in this Report or any other services provided by us. Unless otherwise stated in this report, the assessments made assume that the sites and facilities will continue to be used for their current purpose without significant change.
The conclusions and recommendations contained in this report are based upon information provided by others and upon the assumption that all relevant information has been provided by those parties from whom it has been requested. Information obtained from third parties has not been independently verified by AECOM, unless otherwise stated in the report.
The methodology adopted, and the sources of information used by AECOM in providing its services are outlined in this report. The field work described in this report commenced on December 2020 and is based on the conditions encountered and the information available at the site of investigation during said period of time. The scope of this report and the services are accordingly factually limited by these circumstances.
The report relates to the current state of the site or facilities of investigation only and does not take into account their future development (if any) unless any specific forecasts are made and expressly designated as such.
oooOOOooo
AECOM would like to thank you for the opportunity to work on this project. Please feel free to contact the undersigned, should you have questions regarding any of the issues discussed in this report.
The agreed services relating to hazardous materials in buildings were provided by qualified AECOM employees on the basis of the documents and information provided by the client, taking into account the German and European legal framework, the German Technical Guidelines on Hazardous
Substances (TRGS) as well as the asbestos and PCB directives, assuming correct professional procedure.
In the course of a systematic site examination, the extent of which was defined and agreed upon beforehand, samples were taken of substances which in our judgment appear likely to contain hazardous materials; these samples were taken and analyzed for their hazardous substance content by an accredited analysis laboratory authorized to perform this task.
It cannot be excluded that further hazardous building materials may be found in areas of the site which were not accessible to or made accessible to us in the course of this project or in areas which, according to information provided by you or from a technical point of view, do not contain hazardous materials, or in areas, respectively, in which the existence of hazardous building materials is not immediately recognizable.
Additionally, it cannot be excluded that, as a result of severe fluctuations in the concentration for hazardous substance of a material, samples taken for analysis do not represent the average content.
The results of our survey can only apply specifically to the materials investigated as part of this survey.
Similar materials or materials which appear to be similar, which are located elsewhere may display different characteristics, e.g. in terms of hazardous substance content, even though they may originate from the same manufacturer, have the same identification, or display visual similarity. For the reasons mentioned above, the HAZMAT investigation performed in this project can make no claim to absolute completeness.
APPENDICES
Appendix A Floorplans and Sample Points
BH84-8832-HM-7
BH84-8832-HM-1 BH84-8832-HBCD-1
BH84-8832-AS-1
BH84-8832-HM-3
BH84-8832-HBCD-2
BH84-8832-HM-5 BH84-8832-HM-6
BH84-8832-HM-2
BH84-8832-AS-2
BH84-8832-AS-3
LEGEND
Positive Sample
Fire Door
Negative Sample
H.M.Floor paint
BH84-8832-HM-4
H.M.Wall paint
BH84-8832-LAGA-2
BH84-8832-LAGA-1
BH84-8832-PAH-1
BH84-8832-AS-4
BH84-8832-PAH-2
SHEET ID / BLATT
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
US Army Corps of Engineers
H A
ZM
A
T
SU
R
VE
Y
Appendix B Photo Documentation
Photo documentation Appendix B
Project: Design 84 AFH Units Baumholder, Building 8832
Client: U.S. Army Corps of Engineers, Europe District
Photo 1: Building 8832
Photo 2: Putty (Sample: BH84-8832-AS1)
Photo 3: Wall paint (Sample: BH84-8832-HM2) Outer plaster (Sample: BH84-8832-AS3) Inner plaster (Sample: BH84-8832-AS2)
Photo 4: Tar paper (Sample: BH84-8832-AS-4)
Photo 5: Wall paint (Sample: BH84-8832-HM1)
Photo 6: Floor paint (Sample: BH84-8832-HM3)
Photo 7: Wall paint (Sample: BH84-8832-HM4)
Photo 8: Wall paint, transformer compartment (Sample: BH84-8832-HM5)
Photo 9: Door paint, transformer compartment (Sample: BH84-8832-HM6)
Photo 10: Exterior wall paint (Sample: BH84-8832-HM7)
Photo 11: Hole filler (Sample: BH84-8832-HBCD1)
Photo 12: Hole filler (Sample: BH84-8832-HBCD2)
Photo 13: Tar paper (Sample: BH84-8832-PAH-1)
Photo 14: Tar paper (Sample: BH84-8832-PAH-2)
Photo 15: Wall (Sample: BH84-8832-LAGA-1)
Photo 16: Floor (Sample: BH84-8832-LAGA-2)
Appendix C Laboratory Results
Eurofins Umwelt West GmbH - Vorgebirgsstrasse 20 - D-50389 - Wesseling
AECOM Deutschland GmbH Niederlassung Kaiserslautern Straßburger Allee 2-4 67657 Kaiserslautern
Titel: Prüfbericht zu Auftrag 02150957 Prüfberichtsnummer: AR-21-AN-041378-01
Auftragsbezeichnung: 60641753 Design 84 AFH Units Baumholder
Anzahl Proben: 2 Probenart: Bauschutt / Bausubstanz Probenahmedatum: 22.10.2021 Probenehmer: angeliefert vom Auftraggeber
Probeneingangsdatum: 27.10.2021 Prüfzeitraum: 27.10.2021 - 03.11.2021
Die Prüfergebnisse beziehen sich ausschließlich auf die…