Day Care Center for Children with Disabilities, New Belgrade, Serbia
Attachment # 1 As-Built Bldg. # 34
General Remarks (for details see SOW):
-Replace existing doors. Change interior and exterior doors where required by Life Safety Codes with Fire doors.
- Windows and glass facades are not shown on the new layout. All new windows shall meet local Energy Codes and Safety Codes required for the designated usage.
-Bathrooms shall be handicapped accessible as required by local codes
- Replace tiles in hallway
- Replace flooring in Multipurpose and therapy room -Suspended ceiling throughout the facility -Clean brick wall
Plaster and paint walls--Plaster and paint walls
- Add ramp for handicapped access.
Attachment # 2 Conceptual New Layout Bldg.# 34 NOTE: Drawings not to scale!
Attachment # 3 As-Built Bldg. # 42
-Replace existing doors. Change interior and exterior doors where required by Life Safety Codes with Fire doors.
Wi d d l f d t h th- Windows and glass facades are not shown on the new layout. All new windows shall meet local Energy Codes and Safety Codes required for the designated usage.
-Bathrooms shall be handicapped accessible as required by local codes
- Replace tiles in hallway
- Replace flooring in office and therapy roomp g py -Suspended ceiling throughout the facility -Plaster and paint walls
- Add ramp for handicapped access.
- Remove technical box on wall in therapy room
Attachment # 4 Conceptual New Layout Bldg.# 42
Attachment # 5 As-Built Bldg. # 64
-Replace existing doors. Change interior and exterior doors where required by Life Safety Codes with Fire doors.
- Windows and glass facades are not shown on the new layout. All new windows shall meet local Energy Codes and Safety Codes required for the designated usage.
-Bathrooms shall be handicapped accessible as required by local codeslocal codes
- Replace tiles in hallway
- Replace flooring in Multipurpose and therapy room -Suspended ceiling throughout the facility -Remove partition wall in therapy room -Plaster and paint walls
- Add ramp for handicapped access.p pp
Attachment # 6 Conceptual New Layout Bldg.# 64