This engineering drawing and related solicitation provide details for a sluice gate installation project at Lac qui Parle Dam. The work involves constructing a dewatering box with pier extensions and slots, and replacing nine existing sluice gates and actuators with government-furnished slide gates and actuators stored nearby. A 100A panel, circuit breakers, disconnect switch, and conduit runs will supply power to the new gate actuators. The solicitation is identified as W912ES20B0012 issued by the U.S. Army Corps of Engineers St. Paul District. The selected contractor will install the gates and dewatering system at the dam location in Watson, Minnesota.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
ID
Sheet
ADVERTISE
W E
S
B
N
L Q
P G
R P E -1 d g n2 /0
/0
A S N
O T
E D
A N
S I
D
M
IN
N E
A P
O L
IS
M N
S T
A N
L E
Y C
O N
S U
L T
A N
T S
IN
C
W
A Y
Z A
T A B
L V
D
E-102
R E
B
S T P
A U
L D
IS
T R
IC
T
S T P
A U
L
M
IN
N E
S O
T A
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
B
IL
L H
O L
M A
N
E L E
V A
T
IO
N D
A T
U M
V E
R T
IC
A L C
O N
T R
O L
C O
O R
D
IN
A T
E S
Y S
T E
M
H O
R
IZ
O N
T A
L C
O N
T R
O L
C O
M B
IN
E D F
A C
T O
R
C F
G E
O
ID
N A
D
M N S
P C
S S
O U
T H Z
O N
E -U .S S
U R
V E
Y F
T
N A
V D
8 1
B
.9
P R
O P
O S
E D E
L E
C T
R
IC
A L P
L A
N
(TYP 9)
GATE 1GATE 2GATE 3GATE 4GATE 5GATE 6GATE 7GATE 8GATE 9
SHEET KEYNOTES:
GENERAL SHEET NOTES:
D
A T
E
W A
T S
O N
M N
L A
C Q
U I P
A R
L E D
A M
S L
U
IC
E G
A T
E I
N S
T A
L L
A T
IO
N D
E W
A T
E R
IN
G S
Y S
T E
M
M
IN
N E
S O
T A R
IV
E R
J D
C
J D
C
10' 20'0
B2
PROPOSED ELECTRICAL
PLAN
C4
PANEL P-1
BREAKER MCB-1
MAIN BREAKER
100A
SWITCH MTS-1
TRANSFER
MANUAL
NTS
C4
SCALE:
EXISTING ELECTRICAL CONTROLS
PLAN
2-POLE CIRCUIT BREAKER TO FEED NEW SLUICE GATE.
PROVIDE NEW CIRCUIT BREAKER IN PLACE OF EXISTING2.
LIQUIDTIGHT FLEXIBLE CONDUIT TO ACTUATOR.
ON RAILING FOR SLUICE GATE ACTUATOR. PROVIDE
PROVIDE 100A/3P NEMA 4X DISCONNECT SWITCH MOUNTED1.
COMBINED.
DERATE CABLE AND INCREASE SIZE PER NEC IF
CONDUIT RUNS MAY BE COMBINED BACK TO PANEL P-1.3.
REMAIN DURING CONSTRUCTION.
PROTECT EXISTING CIRCUITS SCHEDULED TO2.
ALONG RAILING OF DAM.
MAIN CONDUIT RUNS SHALL BE ROUTED1.
1"-2#3, 1#8 GRP
P-1-18, 20
1"-2#3, 1#8 GRP
P-1-14, 16
1"-2#3, 1#8 GRP
P-1-13, 15
1"-2#3, 1#8 GRP
P-1-9, 11
"-2#6, 1#8 GRP4
P-1-10, 12
"-2#6, 1#8 GRP4
P-1-6, 8
"-2#6, 1#8 GRP4
P-1-2, 4
1"-2#3, 1#8 GRP
P-1-5, 7
1"-2#3, 1#8 GRP
P-1-1, 3
ST. PAUL DISTRICT
W E
H D
R A
W
IN
G R
E
IS
S U
E D W
IT
H A
M E
N D
M E
N T N
O
/2
/2
| LQPGRP_E-102--- |
| References |
| Prop, PW_WORKDIR:d0665723 |
| LQPGRP_S-LD0001.dgn |
| Border, PW_WORKDIR:d0665721 |
| LQPGRP_Border_G-BSDxxx.dgn |
| Exist, PW_WORKDIR:d0669187 |
| LQPGRP_EXISTING_V-SP0001.dgn |
File details come from the government source that posted it. Updated .