CDC_DRAWING_FILE_-_2019-07-11_Part3.pdf

PDF 20 MB Posted

Attached to
Care and Preservation Vehicle Maintenance Facility
Solicitation number
W912ER19R0021
Issued by

About this file

Care and Preservation Drawings Part 3 of 8

View the file

Other files

File Type Posted
Cost_Breakdown_Sheet_Care_and_Preservation_Facility_as_of__8-22-2019.pdf PDF
AMENDMENT_0004_-_DRAWING_DOCUMENT_--_AJ_CPF_Amendment_0004_Drawings.pdf PDF
W912ER19R0021_0004.pdf PDF
AMENDMENT_0004_SPECIFICATIONS_DOCUMENT_-_CARE_AND_PRES_FAC_29_AUG_19.pdf PDF
W912ER19R0021_0003.pdf PDF
W912ER19R0021-P0002.pdf PDF
AMENDMENT_0002_SPECIFICATIONS_DOCUMENT.pdf PDF
Proposal_Schedule_Care_and_Preservation_Facility__8-5-2019.pdf PDF
Cost_Breakdown_Sheet_Care_and_Preservation_Facility_as_of__8-5-2019.pdf PDF
AMENDMENT_0002_DRAWING_FILE_--_15_AUG_19_AJ_CPF_Amendment_0002_Drawings.pdf PDF
W912ER19R0021_Amendment_0001.pdf PDF
Revised_Camp_Arifjan_Base_Access_-_16JULY19.pdf PDF
CDC_DRAWING_FILE_-_2019-07-11_Part2.pdf PDF
CDC_DRAWING_FILE_-_2019-07-11_Part7.pdf PDF
ATTACHMENT_D_SUPPLEMENTAL_COST_BREAKDOWN_(BID_SCHEDULE).pdf PDF
VOLUME_3_OF_3_SPECS_8_JUL_19.pdf PDF
ATTACHMENT_B_OFFERORS_CONSTRUCTION_EXPERIENCE_FORM.pdf PDF
CDC_DRAWING_FILE_-_2019-07-11_Part8.pdf PDF
VOLUME_2_OF_3_SPECS_8_JUL_19.pdf PDF
QUESTIONNAIRE_-_REQUEST_FOR_INFORMATION_FOR_PURPOSES_OF_CONDUCTING_A_RESPONSIBILITY_DETERMINATION.pdf PDF
VOL_1_OF_3_SOLICITATION.pdf PDF
CDC_DRAWING_FILE_-_2019-07-11_Part5.pdf PDF
CDC_DRAWING_FILE_-_2019-07-11_Part4.pdf PDF
CDC_DRAWING_FILE_-_2019-07-11_Part1.pdf PDF
ATTACHMENT_C_PAST_PERFORMANCE_QUESTIONNAIRE.pdf PDF
CDC_DRAWING_FILE_-_2019-07-11_Part6.pdf PDF
ATTACHMENT_A_CONSTRUCTION_EXPERIENCE_OVERVIEW_SHEET.pdf PDF
BASE_ACCESS_PROCEDURES_FOR_CAMP_ARIFJAN.pdf PDF
Part_1_CDC_Drawings.pdf PDF
Part_3_CDC_Drawings.pdf PDF
Part_4_CDC_Drawings.pdf PDF
Part_2_CDC_Drawings.pdf PDF
Care_and_Preservation_Facility.docx DOCX document
DRAFT_Proposal_Schedule_Care_and_Preservation_Facility-369882__5-15-2019.pdf PDF
DRAFT_Cost_Breakdown_Care_and_Preservation_Facility-369882__5-15-2019.pdf PDF
DRAFT_Specifications_for_Care_&_Preservation_Facility,_Camp_Arifjan,_Kuwait.pdf PDF
Draft_Soliocitation_for_Care_and_Preservation_FBO.pdf PDF
Care_and_Preservation_Capabilities_Statement.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

06/21/2019

PAINT

MIXING

ROOM

PAINT MIXING ROOM CANOPY BY PEMB VENDOR GALV AND PAINTED

PAINT MIXING ROOM

PAINT

MIXING

PAINT MIXING ROOM AS SPECIFIED

NOTES

INSTRUCTIONS TO BIDDER FOR KEYNOTE REFERENCE; THERE ARE TWO

SETS OF KEYNOTES:

1. KEYNOTES REFLECT THE DOCUMENTS AS DESIGNED AND USE

WHOLE NUMBERS. EXAMPLE 1,2, 10, 15, ETC. KEYNOTES ONLY

APPEAR ON THE SPECIFIC DRAWINGS THAT THE NOTES APPLY TO.

2. BID OPTION KEYNOTES REFLECT ONE OF THE FIVE ADDITIVE BID

OPTIONS (DESCRIBED ON THIS DRAWING) AND USE DECIMAL

PLACES. EXAMPLE ( FOR BID OPTION #1) 1.1, 1.2, 1.10, 1.15, ETC.

FOR (BID OPTION #2) IT SHALL READ 2.1, 2.2, 2.10, 2.15, ETC. THESE

NUMBERS SHALL REFERENCE SPECIFIC SCOPE ITEMS AND MAY

APPEAR MULTIPLE TIMES ON MULTIPLE SHEETS.

BID OPTION #1

BID OPTION #2

BID OPTION #3

BID OPTION #4

BID OPTION #5

1.3

BID OPTION NUMBER

BID OPTION NOTE

(SUCCESSIVE)

BID OPTION KEYNOTE

BID OPTION LEGEND

GREY FILL INDICATES AREA OF BID OPTION

BID OPTION DESCRIPTION OF

WORK

BID OPTION #1: PROVIDE ONE SERVICE BAY FOR THE

ENTIRE WIDTH OF THE FACILITY (COLUMN

GRID LINES C TO L) INSERTED IN SERVICE

BAYS 1200 AT COLUMN GRID LINE 16.

BID OPTION #2: PROVIDE FIRST FLOOR (UPPER LEVEL)

ADMINISTRATIVE AREA BETWEEN COLUMN

GRID LINES 8 AND 12.

BID OPTION #3: PROVIDE TWO 900KW PRIME-RATED

GENERATORS AND REVISE WIRING AND

EQUIPMENT AS REQUIRED.

BID OPTION #4: PROVIDE PARKING SUNSHADE.

BID OPTION #5: PROVIDE HAZMAT PAD.

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:27:30 PM

6/

/ 2

8:

:3

P

M

I-003

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A- I0

G

N

BI

D

O P T

IO

N

N O

TE

S

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

BID OPTION KEY NOTES

KEYNOTE NUMBER

(REFER TO BID

OPTION LEGEND) BID OPTION DESCRIPTION

1.0 INDICATE SERVICE BAY FOR THE ENTIRE WIDTH OF THE FACILITY AT THE EAST END OF THE BUILDING BETWEEN COLUMNS 16 AND 17. THIS WILL REQUIRE ARCHITECTURAL AND STRUCTURAL DESIGN WORK, MECHANICAL DESIGN CALCULATIONS BASED ON A REDUCED VOLUME OF THE SPACE AND A REDUCED NUMBER OF VEHICLE EXHAUST INTAKE LOCATIONS, REVISED ELECTRICAL AND TELECOM DESIGN, AND REVISED GRADING AND UTILITY PROFILE DRAWINGS TO REFLECT THE REDUCED BUILDING FOOTPRINT. THE OUTDOOR EQUIPMENT AT THE EAST END OF THE BUILDING WILL ALSO NEED TO BE MOVED TO REMAIN

ADJACENT TO THE BUILDING. REFER TO DRAWING A-140 FOR BASE BID.

1.2 RELOCATE EQUIPMENT WITH THE IMPLEMENTATION OF BID OPTION #1. REFER TO DRAWING A-116_A FOR BASE BID CONDITIONS.

2.0 OPENINGS NEAR 8C-L AND 12C-L SHALL BE INFILLED WITH KNOCK-OUT 1 HOUR RATED PANELS OF METAL STUF AND GYPSUM BOARD.

2.1 THE INTERIOR FACE OF THE EXTERIOR WALL IS UNFINISHED.

2.2 FIRE RATED WALLS ADJACENT TO THE VEHICLE BAYS SHALL BE INSTALLED.

2.3 REFER TO MECHANICAL DRAWINGS FOR BID OPTION #2 LAYOUT REVISIONS. COORDINATE FLOOR PENETRATIONS TO ALLOW FUTURE SYSTEMS.

2.4 CHILLER-SLAB AND SCREEN WALL SHALL REMAIN. COORDINATE EQUIPMENT LAYOUT CHANGE WITH MECHANICAL AND ELECTRICAL DOCUMENTS.

2.10 WALLS AND DOORS OF STAIRS NEAR C11 SHALL BE INSTALLED. DOOR FROM STAIR LANDING AREA TO SPACE SHALL BE SECURED WITH A RESTRICTED ACCESS SYSTEM.

2.11 THE ELEVATOR SHAFT SHALL BE INSTALLED BUT NO ELEVATOR SYSTEMS SHALL BE INSTALLED. OPENINGS IN THE ELEVATOR SHAFT SHALL BE CLOSED WITH 1 HOUR RATED KNOCK-OUT PANELS OF METAL STUD AND GYPSUM BOARD.

2.12 IN THE AREA NEAR 8E-F, PLUMBING SYSTEMS WHICH DO NOT GO THROUGH THE ROOF SHALL BE TERMINATED 300 FEET ABOVE THE FLOOR.

1 2 3 4 5 6 7 9 10 128 11 14 18 19 20 21

J

D

L K

G

C

A

13 15 16 17

B

F

E

M

H SERVICE

BAYS

SHIPPING/RECEIVING

WAREHOUSE

STAIR

TIRE

REPAIR

HYDRAULIC

ROOM

SERVICE

BAYS

WELD

SHOP

BLAST

BOOTH

PAINT

BOOTH

CORROSION

CONTROL

CENTER

CHILLER

ENCLOSURE

1610B

ELECTRICAL

ROOM

MECHANICAL

OFFICE

PARTS

STORAGE

GENERAL

STORAGE

BREAK

ROOM

1616A

OFFICE

TOOL

STORAGE

STORAGE

1616B

STAIR

ELEV

#1

1404E

ELEV

MR

VEST

LOBBY

TELECOM

FIRE

EQUIPMENT

ROOM

STORAGE

ROOM

MENS

LOCKER

1608B

TOOL

STORAGE

WOMEN

1607B

WOMENS

LOCKER

1607A CORRIDOR

CORRIDOR

AIRLOCK

LOCKER

ROOM

CHANGING

TOILET

1404A

MEN

1608A

JANITORS

CLOSET

B BOOKCASE WITH STORAGE BELOW

C CHAIR

D DESK

F FILE CABINET

M MARKER BOARD/ TACK BOARD/ CLOCK

P PRINTER CART

R TRASH/ RECYCLE RECEPTACLE

S SHELVING

T TABLE

W WORKSTATION (SYSTEMS FURNITURE)

FURNITURE ABBREV.

EQUIPMENT ABBREV.

CO COFFEE MAKER

CP COMPUTER, OFOI

MW MICROWAVE

PR PRINTER/ FLOOR COPIER, OFOI

RF REFRIGERATOR

VD VENDING MACHINE, OFOI

*OFOI = OWNER FURNISHED OWNER INSTALLED.

BID OPTION #1

BID OPTION #2

BID OPTION #3

BID OPTION #4

BID OPTION #5

1.3

BID OPTION NUMBER

BID OPTION NOTE

(SUCCESSIVE)

BID OPTION KEYNOTE

BID OPTION LEGEND

GREY FILL INDICATES AREA OF BID OPTION

GRAPHIC SCALE

PLAN NORTH

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D F

1:400

40m8m 32m24m16m0m

E L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:28:38 PM

6/

/ 2

8:

:3

P

M

IF110

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IF

0P

N

IN

TE

R

IO

R S

G R

O U

N D

F

LO

O R

F U

R N

IT

U

R E

PL

AN

O

VE

R

AL

L

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 400A1

GROUND FLOOR FURNITURE PLAN

OVERALL

GENERAL SHEET NOTES

1. SEE THE FURNITURE, FIXTURES, AND EQUIPMENT SUBMITTAL (CID) FOR

ADDITIONAL INFORMATION.

2. THE PROCUREMENT AND INSTALLATION OF FURNITURE IS NOT PART OF THE

CONSTRUCTION CONTRACT.

3. COORDINATE FINAL FURNITURE LOCATIONS WITH OTHER DISCIPLINES.

4. TACK BOARD BOTTOMS AND MARKER BOARD BOTTOMS & MARKER TRAY TO

BE MOUNTED 914MM (36") ABOVE FINISH FLOOR. TYP.

5. PROVIDE BLOCKING IN WALL AT MARKER BOARD AND TACK BOARD

LOCATIONS.

6. PROVIDE BLOCKING IN WALL AT ALL BOOK CASE LOCATIONS (B1). SECURE

TO WALL.

7. PROVIDE BLOCKING IN WALL AT ALL DESK HUTCH LOCATIONS. (D1). SECURE

OVERHEAD HUTCH AND CABINETS TO WALL.

8. FURNURE VENER RESPONSIBLE FOR ACCURATE QUANTITES BASED ON

FURNITURE FLOOR PLANS.

9. EQUIPMENT IS OFOI (OWNER FURNISHED OWNER INSTALLED). IT IS SHOWN

FOR CORDINATION PURPOSES ONLY.

C1

D2

D2

R1 R2

R2 R1

1 2 3 4

J

D

L

K

G

C

B

F

E

M

H

SERVICE

BAYS

B BOOKCASE WITH STORAGE BELOW

C CHAIR

D DESK

F FILE CABINET

M MARKER BOARD/ TACK BOARD/ CLOCK

P PRINTER CART

R TRASH/ RECYCLE RECEPTACLE

S SHELVING

T TABLE

W WORKSTATION (SYSTEMS FURNITURE)

FURNITURE ABBREV.

EQUIPMENT ABBREV.

CO COFFEE MAKER

CP COMPUTER, OFOI

MW MICROWAVE

PR PRINTER/ FLOOR COPIER, OFOI

RF REFRIGERATOR

VD VENDING MACHINE, OFOI

*OFOI = OWNER FURNISHED OWNER INSTALLED.

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:29:13 PM

6/

/ 2

8:

:1

P

M

IF111

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IF

1P

N

IN

TE

R

IO

R S

G R

O U

N D

F

LO

O R

F U

R N

IT

U

R E

PL

AN

AR

EA

A

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

GENERAL SHEET NOTES

1 : 100A1

GROUND FLOOR FURNITURE PLAN

AREA A

1. SEE THE FURNITURE, FIXTURES, AND EQUIPMENT SUBMITTAL (CID) FOR

ADDITIONAL INFORMATION.

2. THE PROCUREMENT AND INSTALLATION OF FURNITURE IS NOT PART OF THE

CONSTRUCTION CONTRACT.

3. COORDINATE FINAL FURNITURE LOCATIONS WITH OTHER DISCIPLINES.

4. TACK BOARD BOTTOMS AND MARKER BOARD BOTTOMS & MARKER TRAY TO

BE MOUNTED 914MM (36") ABOVE FINISH FLOOR. TYP.

5. PROVIDE BLOCKING IN WALL AT MARKER BOARD AND TACK BOARD

LOCATIONS.

6. PROVIDE BLOCKING IN WALL AT ALL BOOK CASE LOCATIONS (B1). SECURE

TO WALL.

7. PROVIDE BLOCKING IN WALL AT ALL DESK HUTCH LOCATIONS. (D1). SECURE

OVERHEAD HUTCH AND CABINETS TO WALL.

8. FURNURE VENER RESPONSIBLE FOR ACCURATE QUANTITES BASED ON

FURNITURE FLOOR PLANS.

9. EQUIPMENT IS OFOI (OWNER FURNISHED OWNER INSTALLED). IT IS SHOWN

S1

C1

C1

C1 M1

C1

C1

F1 C1M1

M1

C1

S1

S1

S1

C3

C3

T3 C2 C2

C2C2

M1

T3

C2

C2

C2

C2

D2

D2D2

T5

D2 D2 C1

R

R

CP1

CP1

R1 R2

B1

B1

R1 R1

R1R2

R1 R2

CP1

CP1

CP1 CP1

CP1

CP1

CP1

B1

R

R

R3R4

M4

C1D2

CP1

C1 D2

C1 D2

C1D2

CP1

CP1

CP1

S1

S1

S1

S1

S1

S1

D1

D1

D1

D1

M1

B1

S1S1S1S1

S1 S1

C5

C5

C5

C5

C3

R5 R6

T2

T2

T2

T2

M1 M1

M4M4

T2

C5

C3

C5

C5

C5

C5

C5

C5

C5

C5

C5

C5

VD1

VD1

RF1

RF1

R6R5

R6R5

MW1

MW1

CO1

CO1

7 9 10 128 11

J

D

L

K

G

C

B

F

E

M

H

C5

HYDRAULIC

ROOM

TIRE

REPAIR

GENERAL

STORAGE

PARTS

STORAGE

OFFICE

TOOL

STORAGE

WOMEN

1607B

WOMENS

LOCKER

1607A

JANITORS

CLOSET

CORRIDOR

MENS

LOCKER

1608B

MEN

1608A

STORAGE

ROOM

MECHANICAL

1610 FIRE

EQUIPMENT

ROOM

TELECOM

1613 VEST

LOBBY

ELEV

#1

1404E

ELEV

MR

ELECTRICAL

ROOM

TOOL

STORAGE

STORAGE

1616B

STAIR

BREAK

ROOM

1616A

OFFICE

CORRIDOR

WAREHOUSE

STAIR

SHIPPING/RECEIVING

2.3

2.1

B BOOKCASE WITH STORAGE BELOW

C CHAIR

D DESK

F FILE CABINET

M MARKER BOARD/ TACK BOARD/ CLOCK

P PRINTER CART

R TRASH/ RECYCLE RECEPTACLE

S SHELVING

T TABLE

W WORKSTATION (SYSTEMS FURNITURE)

FURNITURE ABBREV.

EQUIPMENT ABBREV.

CO COFFEE MAKER

CP COMPUTER, OFOI

MW MICROWAVE

PR PRINTER/ FLOOR COPIER, OFOI

RF REFRIGERATOR

VD VENDING MACHINE, OFOI

*OFOI = OWNER FURNISHED OWNER INSTALLED.

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:29:58 PM

6/

/ 2

8:

:5

P

M

IF113

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IF

3P

N

IN

TE

R

IO

R S

G R

O U

N D

F

LO

O R

F U

R N

IT

U

R E

PL

AN

AR

EA

C

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1

GROUND FLOOR FURNITURE PLAN

AREA C

GENERAL SHEET NOTES

1. SEE THE FURNITURE, FIXTURES, AND EQUIPMENT SUBMITTAL (CID) FOR

ADDITIONAL INFORMATION.

2. THE PROCUREMENT AND INSTALLATION OF FURNITURE IS NOT PART OF THE

CONSTRUCTION CONTRACT.

3. COORDINATE FINAL FURNITURE LOCATIONS WITH OTHER DISCIPLINES.

4. TACK BOARD BOTTOMS AND MARKER BOARD BOTTOMS & MARKER TRAY TO

BE MOUNTED 914MM (36") ABOVE FINISH FLOOR. TYP.

5. PROVIDE BLOCKING IN WALL AT MARKER BOARD AND TACK BOARD

LOCATIONS.

6. PROVIDE BLOCKING IN WALL AT ALL BOOK CASE LOCATIONS (B1). SECURE

TO WALL.

7. PROVIDE BLOCKING IN WALL AT ALL DESK HUTCH LOCATIONS. (D1). SECURE

OVERHEAD HUTCH AND CABINETS TO WALL.

8. FURNURE VENER RESPONSIBLE FOR ACCURATE QUANTITES BASED ON

FURNITURE FLOOR PLANS.

9. EQUIPMENT IS OFOI (OWNER FURNISHED OWNER INSTALLED). IT IS SHOWN

FOR CORDINATION PURPOSES ONLY.

KEYNOTES

10 PALLET RACKING, SEE ARCHITECTURAL DRAWINGS FOR

DETAILS.

11 ATTACH FREESTANDING SHELVING UNIT TO WALL FOR

SECURITY. REFER TO ARCHITECTURAL FOR BLOCKING.

FOR BID OPTION KEYNOTES REFER TO BID

OPTION LEGEND ON APPLICABLE DRAWINGS

AND BID OPTION NOTES ON DRAWING A-003

D2

D2

R2 R1

R1 R2

12 14

J

D

L

K

G

C

13 15 16

B

F

E

M

H

SERVICE

BAYS

B BOOKCASE WITH STORAGE BELOW

C CHAIR

D DESK

F FILE CABINET

M MARKER BOARD/ TACK BOARD/ CLOCK

P PRINTER CART

R TRASH/ RECYCLE RECEPTACLE

S SHELVING

T TABLE

W WORKSTATION (SYSTEMS FURNITURE)

FURNITURE ABBREV.

EQUIPMENT ABBREV.

CO COFFEE MAKER

CP COMPUTER, OFOI

MW MICROWAVE

PR PRINTER/ FLOOR COPIER, OFOI

RF REFRIGERATOR

VD VENDING MACHINE, OFOI

*OFOI = OWNER FURNISHED OWNER INSTALLED.

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:30:42 PM

6/

/ 2

8:

:4

P

M

IF114

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

=u

IN

TE

R

IO

R S

G R

O U

N D

F

LO

O R

F U

R N

IT

U

R E

PL

AN

AR

EA

D

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

GENERAL SHEET NOTES

1 : 100A1

GROUND FLOOR FURNITURE PLAN

AREA D

1. SEE THE FURNITURE, FIXTURES, AND EQUIPMENT SUBMITTAL (CID) FOR

ADDITIONAL INFORMATION.

2. THE PROCUREMENT AND INSTALLATION OF FURNITURE IS NOT PART OF THE

CONSTRUCTION CONTRACT.

3. COORDINATE FINAL FURNITURE LOCATIONS WITH OTHER DISCIPLINES.

4. TACK BOARD BOTTOMS AND MARKER BOARD BOTTOMS & MARKER TRAY TO

BE MOUNTED 914MM (36") ABOVE FINISH FLOOR. TYP.

5. PROVIDE BLOCKING IN WALL AT MARKER BOARD AND TACK BOARD

LOCATIONS.

6. PROVIDE BLOCKING IN WALL AT ALL BOOK CASE LOCATIONS (B1). SECURE

TO WALL.

7. PROVIDE BLOCKING IN WALL AT ALL DESK HUTCH LOCATIONS. (D1). SECURE

OVERHEAD HUTCH AND CABINETS TO WALL.

8. FURNURE VENER RESPONSIBLE FOR ACCURATE QUANTITES BASED ON

FURNITURE FLOOR PLANS.

9. EQUIPMENT IS OFOI (OWNER FURNISHED OWNER INSTALLED). IT IS SHOWN

C5

C1

VD1 VD1

RF1

C5

C5

C5

C5

C5C5

C5

C5

C5C5

C5

C1 C1

C1

C1

C1

C1 C1

C1

C1 C1

C1

C1

C2 C2

C2 C2

C1

C1

C1

C1 C2 C2

C4

C4C4

W1

W1 W1

W1

W1W1

W1

W1

W1

W1

W1W1

B1

B1PR1

PR1

M1 M1

M1

M1

M1

M1

M1

M1

M1

CO1

T2

T2

T2

C5C5

C5

T2

C2 C2

B1

C1C2 C2

B1

C1C2 C2

C1C2 C2

B1

PR2

C4 C4

C4 C4

C1

C1

C1

W1

W1

W1

C1

W1

C1C1

C1C1

W1

W1W1

W1

C1

C1

W1

W1

C1

C1 C1

C1

C1 C1

C1 C1

W1

W1

W1 W1 W1

W1

W1

W1

C1 C1

PR1

B1

C2 C2 C1

C2 C2

C1

B1

C2 C2

C1 B1

W1

C1

W1

C1 C1

W1W1

W1

C1C1

B1

C5

M2

C4

M1

T3

C2

C2

C2

C2 C1

B1

PR2

PR1

C3

C3

T4

VD1

D2

D2

D2

F1 F1 F1

M2

M1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1CP1

CP1

CP1CP1

PR1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1 CP1CP1

CP1 CP1 CP1

CP1

CP1

CP1 CP1

R1 R2

R1 R2

R

R1 R2

R1 R2R2

R1 R2 R1

R1 R2

R2 R1

R1 R2 R1

R2

R

R

R

R

R

R

R

R

R

R

R

R 2 R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R1 R2

R1 R2

R1R2

R1 R2

R1 R2

R1 R2

R1 R2

R1 R2

R1 R2

R2 R1

R2 R1

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R 1 R

R

R1

R4 R3

R3R4

R5

R6

M4

M4

M4

M1

M3

CP1

C1

CP1

PR2

C3 C3

T5 C3C3

F1F1F1F1 F1 F1 F1 F1

T5

C3 C3

C3C3

C1

R4 R3

F1 D1

D1

D1

D1

D1

D1

D1

D1

D1

CP1

CP1

T2

R

R

CP1

P1

S1

S1

S1 S1 S1

S1

S1

S1

S1

S1 S1 S1

S1 S1 S1 S1 S1

S1 S1 S1 S1 S1 S1 S1

R

R

C4 C4 C4 C4 C4

C4 C4C4

C4

C4 C4 C4

T1

T1 T1

T1

T1

T1C4

M2 M4

C4

C4T1

M2M4 R

R

C4 C4 C4 C4 C4

C4

T1

T1

T1

T1

C4

C4 C4 C4 C4 C4

T1

T1

T1 C4C4C4

C4

C4 C4 C4 C4 C4

C4

D2 C4

CP1

D2 C4

CP1

C1

W1

C1

W1

CP1 CP1

R1 R2

R1R2

4'

0" M

IN

.2

C2 C2

W1

W1 W1

T5

C3C3

C3C3

B1

RF1

MW1

MW1

7 9 10 128 11

J

D

L

K

G

C

B

F

E

M

H

GOVERNMENT

STAFF

CONFERENCE

ROOM

CONFERENCE

ROOM

STORAGE

MEN

STORAGE

JAN

WOMEN

CAFE

SIPR

TELECOM

RECEPTION

VESTIBULE

ASST

MNGR

MNGR

OFFICE

OPEN

OFFICE

ELEV

#1

1404E

ELECTRICAL

ROOM

STORAGE

2115STAIR

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STAIR

CONFERENCE

ROOM

CONFERENCE

ROOM

OPEN

OFFICE

2.10

2.10

2.11

2.2

2.0

2.12

4' - 0"

MIN.

1219.20

D1

D1

B1

B BOOKCASE WITH STORAGE BELOW

C CHAIR

D DESK

F FILE CABINET

M MARKER BOARD/ TACK BOARD/ CLOCK

P PRINTER CART

R TRASH/ RECYCLE RECEPTACLE

S SHELVING

T TABLE

W WORKSTATION (SYSTEMS FURNITURE)

FURNITURE ABBREV.

EQUIPMENT ABBREV.

CO COFFEE MAKER

CP COMPUTER, OFOI

MW MICROWAVE

PR PRINTER/ FLOOR COPIER, OFOI

RF REFRIGERATOR

VD VENDING MACHINE, OFOI

*OFOI = OWNER FURNISHED OWNER INSTALLED.

BID OPTION #1

BID OPTION #2

BID OPTION #3

BID OPTION #4

BID OPTION #5

1.3

BID OPTION NUMBER

BID OPTION NOTE

(SUCCESSIVE)

BID OPTION KEYNOTE

BID OPTION LEGEND

GREY FILL INDICATES AREA OF BID OPTION

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:32:12 PM

6/

/ 2

8:

:1

P

M

IF123

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IF

3P

N

IN

TE

R

IO

R S

FI

R

ST

F

LO

O

R F

U R

N

IT

U R

E

PL

AN

AR

EA

A

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1 FIRST FLOOR FURNITURE PLAN AREA C

GENERAL SHEET NOTES

1. SEE THE FURNITURE, FIXTURES, AND EQUIPMENT SUBMITTAL (CID) FOR

ADDITIONAL INFORMATION.

2. THE PROCUREMENT AND INSTALLATION OF FURNITURE IS NOT PART OF THE

CONSTRUCTION CONTRACT.

3. COORDINATE FINAL FURNITURE LOCATIONS WITH OTHER DISCIPLINES.

4. TACK BOARD BOTTOMS AND MARKER BOARD BOTTOMS & MARKER TRAY TO

BE MOUNTED 914MM (36") ABOVE FINISH FLOOR. TYP.

5. PROVIDE BLOCKING IN WALL AT MARKER BOARD AND TACK BOARD

LOCATIONS.

6. PROVIDE BLOCKING IN WALL AT ALL BOOK CASE LOCATIONS (B1). SECURE

TO WALL.

7. PROVIDE BLOCKING IN WALL AT ALL DESK HUTCH LOCATIONS. (D1). SECURE

OVERHEAD HUTCH AND CABINETS TO WALL.

8. FURNURE VENER RESPONSIBLE FOR ACCURATE QUANTITES BASED ON

FURNITURE FLOOR PLANS.

9. EQUIPMENT IS OFOI (OWNER FURNISHED OWNER INSTALLED). IT IS SHOWN

FOR CORDINATION PURPOSES ONLY.

KEYNOTES

11 ATTACH FREESTANDING SHELVING UNIT TO WALL FOR

SECURITY. REFER TO ARCHITECTURAL FOR BLOCKING.

19 SAFE, GFGI

FOR BID OPTION KEYNOTES REFER TO BID

OPTION LEGEND ON APPLICABLE DRAWINGS

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:32:39 PM

6/

/ 2

8:

:3

P

M

IF601

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IF

1S

C

IN

TE

R

IO

R S

F U R

N

IT

U R

E

FI

X T U

R

ES

A N

D E

Q U

IP

M

E N T

SC

H

ED

U

LE

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

GROUND FLOOR EQUIPMENT SCHEDULE

EQUIPMENT # DESCRIPTION QNTY RESPONSE

CO1 POUR OVER COFFEE MACHINE 2 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

CP1 COMPUTER (CPU/ DUAL MONITORS/

KEYBOARD)

13 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

MW1 MICROWAVE 2 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI) RF1 REFRIGERATOR 2 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI) VD1 VENDING MACHINE 2 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

FIRST FLOOR EQUIPMENT SCHEDULE - BID OPTION #2

EQUIPMENT # DESCRIPTION QNTY RESPONSE

CO1 POUR OVER COFFEE MACHINE 1 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

CP1 COMPUTER (CPU/ DUAL MONITORS/

KEYBOARD)

57 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

MW1 MICROWAVE 2 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI) PR1 PRINTER 5 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

PR2 FLOOR COPIER/ PRINTER/ SCANNER

COMBO

3 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

RF1 REFRIGERATOR 2 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI) VD1 VENDING MACHINE 3 FOR REFERENCE ONLY. NOT IN CONTRACT (NIC), OWNER FURNISHED OWNER INSTALLED (OFOI)

GROUND FLOOR FURNITURE SCHEDULE

FURNITURE # DESCRIPTION QNTY

B1 BOOKCASE WITH STORAGE BELOW 4

C1 TASK CHAIR 17

C2 OFFICE GUEST CHAIR 8

C3 LOBBY CHAIR 4

C5 CAFE CHAIR 16

D1 PRIVATE OFFICE L-SHAPED DESK 4

D2 5' (1524MM) WIDE X 30" (762MM) DEEP DESK 13

F1 36" (914.4MM) WIDE 1 DOOR WITH FIXED SHELF, 4 DRAWERS, LATERAL FILE

CABINET - LOCKING

M1 4'WX30"H MARKER BOARD W/ TRAY 7

M4 BATTERY OPERATED WALL CLOCK 3

R1 26.6 LITER TRASH RECEPTACLE 11

R2 26.6 LITER RECYCLE RECEPTACLE 9

R3 87 LITER TRASH RECEPTACLE 1

R4 87 LITER RECYCLE RECEPTACLE 1

R5 132.5 LITER TRASH RECEPTACLE 2

R6 132.5 LITER RECYCLE RECEPTACLE 2

S1 3' (914.40MM) WIDE X 18" 475.20MM) DEEP X 63" (1600MM) HIGH METAL CABINET WITH

3 ADJUSTABLE SHELVES AND NO DOORS

T2 42" (1066.8MM) DIA. CAFE TABLE 4

T3 4' (MM) DIA ROUND CONFERENCE TABLE 2

T5 3' (914.40MM) DIA ROUND ACCENT TABLE 1

FIRST FLOOR FURNITURE SCHEDULE - BID OPTION #2

FURNITURE # DESCRIPTION QNTY

B1 BOOKCASE WITH STORAGE BELOW 12

C1 TASK CHAIR 54

C2 OFFICE GUEST CHAIR 26

C3 LOBBY CHAIR 14

C4 CONFERENCE TASK CHAIR 47

C5 CAFE CHAIR 16

D1 PRIVATE OFFICE L-SHAPED DESK 11

D2 5' (1524MM) WIDE X 30" (762MM) DEEP DESK 5

F1 36" (914.4MM) WIDE 1 DOOR WITH FIXED SHELF, 4 DRAWERS, LATERAL FILE

CABINET - LOCKING

M1 4'WX30"H MARKER BOARD W/ TRAY 12

M2 10'WX4'H MARKER BOARD W/ TRAY 4

M3 4'WX30"H MARKER BOARD W/ TRAY 1

M4 BATTERY OPERATED WALL CLOCK 5

P1 PRINTER CABINET 1

R1 26.6 LITER TRASH RECEPTACLE 57

R2 26.6 LITER RECYCLE RECEPTACLE 56

R3 87 LITER TRASH RECEPTACLE 3

R4 87 LITER RECYCLE RECEPTACLE 3

R5 132.5 LITER TRASH RECEPTACLE 1

R6 132.5 LITER RECYCLE RECEPTACLE 1

S1 3' (914.40MM) WIDE X 18" 475.20MM) DEEP X 63" (1600MM) HIGH METAL CABINET

WITH 3 ADJUSTABLE SHELVES AND NO DOORS

T1 5' (1524MM) WIDE X 2'-6" (762MM) DEEP X 28.5" (723.9MM) HIGH CONFERENCE

TRAINING TABLE

T2 42" (1066.8MM) DIA. CAFE TABLE 5

T3 4' (MM) DIA ROUND CONFERENCE TABLE 1

T4 ACCENT END TABLE 1

T5 3' (914.40MM) DIA ROUND ACCENT TABLE 3

W1 8' (2438.4MM) X 8' (2438.4MM) WORKSTATION 40

*FURNITURE VENER RESPONSIBLE FOR ACCURATE QUANTITES BASED ON FURNITURE FLOOR PLANS.

*FURNITURE VENER RESPONSIBLE FOR ACCURATE QUANTITES BASED ON FURNITURE FLOOR PLANS.

*ALL COMPUTERS, EQUIPMENT, ETC. ARE TO BE SECURED TO SURFACE IN SEISMIC ZONE. ALL BREAK ROOM EQUIPMENT TO BE SECURED TO SURFACE IN SEISMIC ZONE. REFRIGERATORS AND VENDING MACHINES TO BE SECURED TOFLOOR AND / OR WALLS. CONFIRM REFRIGERATOR DOORS DO NOT NEED SEISMIC LATCHES

PRIOR TO PURCHASE.

*ALL COMPUTERS, EQUIPMENT, ETC. ARE TO BE SECURED TO SURFACE IN SEISMIC ZONE. ALL BREAK ROOM EQUIPMENT TO BE SECURED TO SURFACE IN SEISMIC ZONE. REFRIGERATORS AND VENDING MACHINES TO BE SECURED TOFLOOR AND / OR WALLS. CONFIRM REFRIGERATOR DOORS DO NOT NEED SEISMIC LATCHES

PRIOR TO PURCHASE.

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

1 2 3 4 5 6 7 9 10 128 11 14 18 19 20 21

J

D

L K

G

C

A

13 15 16 17

B

F E

M

H

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

SHIPPING/RECEIVING

WAREHOUSE

STAIR

OFFICE

PARTS

STORAGE

GENERAL

STORAGE

HYDRAULIC

ROOM

TIRE

REPAIR

1201WOMEN

1607B

WOMENS

LOCKER

1607A

JANITORS

CLOSET

CORRIDOR

BREAK

ROOM

1616A

OFFICE

TOOL

STORAGE

STORAGE

1616B

ELECTRICAL

ROOM

STAIR

ELEV

#1

1404E

ELEV

MR

VEST

LOBBY

STORAGE

ROOM

TELECOM

FIRE

EQUIPMENT

ROOM

MECHANICAL

MENS

LOCKER

1608B

TOOL

STORAGE

SERVICE

BAYS

CORRIDOR

MEN

1608A

CHILLER

ENCLOSURE

1610B

WELD

SHOP

PAINT

BOOTH

CORROSION

CONTROL

CENTER

BLAST

BOOTH

TOILET

1404ACHANGING

1403 LOCKER

ROOM

AIRLOCK

SERVICE

BAYS

BID OPTION #1

BID OPTION #2

BID OPTION #3

BID OPTION #4

BID OPTION #5

1.3

BID OPTION NUMBER

BID OPTION NOTE

(SUCCESSIVE)

BID OPTION KEYNOTE

BID OPTION LEGEND

GREY FILL INDICATES AREA OF BID OPTION

GRAPHIC SCALE

PLAN NORTH

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D F

1:400

40m8m 32m24m16m0m

E L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:44:12 PM

6/

/ 2

8:

:1

P

M

IN110

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

0P

N

IN

TE

R

IO

R S

G R

O U

N D

F L O

O R

F

IN

IS

H

P

LA

N O

VE

R

AL

L

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

SERVICE BAY AREAS.

1 : 400A1

GROUND FLOOR FINISH PLAN AREA

OVERALL

1 2 3 4

J

D

L

K

G

C

B

F

E

M

H

SERVICE

BAYS

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:44:42 PM

6/

/ 2

8:

:4

P

M

IN111

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

1P

N

IN

TE

R

IO

R S

G R

O U

N D

F L O

O R

F

IN

IS

H

P

LA

N

AR

EA

A

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1 GROUND FLOOR FINISH PLAN AREA A

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

SERVICE BAY AREAS.

4 5 6 7 8

D

L

K

G

C

B

F

E

M

H

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

SERVICE

BAYS

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:45:12 PM

6/

/ 2

8:

:1

P

M

IN112

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

2P

N

IN

TE

R

IO

R S

G R

O U

N D

F L O

O R

F

IN

IS

H

P

LA

N

AR

EA

B

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1 GROUND FLOOR FINISH PLAN AREA B

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

CG2 CG2

CG2CG2

CG2 CG2

CG2CG2

CG2

CG2

CG2

CG2

CG2

CG2

CG2

CG2

CG1 CG1

WP1

CG1

CG1

PT

-3

PT

-3

WP1 WP1 WP1 WP1

WP1 WP1

WP1

PWT-2 & 3

PW

T-

3PT

-3

PT-3 PT-3

7 9 10 128 11

J

D

L

K

G

C

B

F

E

M

H

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

PT

-3

WAREHOUSE

SHIPPING/RECEIVING

OFFICE

PARTS

STORAGE

GENERAL

STORAGE

HYDRAULIC

ROOM

TIRE

REPAIR

CORRIDOR

TOOL

STORAGE

WOMEN

1607B

WOMENS

LOCKER

1607A

JANITORS

CLOSET

MEN

1608A

MENS

LOCKER

1608B

CORRIDOR

BREAK

ROOM

1616A

MECHANICAL

STORAGE

ROOM

FIRE

EQUIPMENT

ROOM

TELECOM

ELEV

MR

ELEV

#1

1404E

VEST

LOBBY

STORAGE

1616B

STAIR

ELECTRICAL

ROOM

TOOL

STORAGE

OFFICE

CHILLER

ENCLOSURE

1610B

STAIR

2.1

2.3

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:46:01 PM

6/

/ 2

8:

:0

P

M

IN113

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

3P

N

IN

TE

R

IO

R S

G R

O U

N D

F L O

O R

F

IN

IS

H

P

LA

N

AR

EA

C

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1 GROUND FLOOR FINISH PLAN AREA C

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

12 14

D

L

K

G

C

13 15 16

B

F

E

M

H

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

SERVICE

BAYS

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:46:39 PM

6/

/ 2

8:

:3

P

M

IN114

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

4P

N

IN

TE

R

IO

R S

G R

O U

N D

F L O

O R

F

IN

IS

H

P

LA

N

AR

EA

D

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1 GROUND FLOOR FINISH PLAN AREA D

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

18 19 20

D

L

K

G

C

16 17

B

F

E

M

H

M

A

TC

H L

IN

E

S E

E

M

A

TC

H L

IN

E

S E

E

WELD

SHOP

SERVICE

BAYS

TOILET

1404A

CHANGING

LOCKER

ROOM

AIRLOCK

CORROSION

CONTROL

CENTER

1.0

1.2

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

BID OPTION #1

BID OPTION #2

BID OPTION #3

BID OPTION #4

BID OPTION #5

1.3

BID OPTION NUMBER

BID OPTION NOTE

(SUCCESSIVE)

BID OPTION KEYNOTE

BID OPTION LEGEND

GREY FILL INDICATES AREA OF BID OPTION

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:47:10 PM

6/

/ 2

8:

:1

P

M

IN115

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

5P

N

IN

TE

R

IO

R S

G R

O U

N D

F L O

O R

F

IN

IS

H

P

LA

N

AR

EA

E

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1 GROUND FLOOR FINISH PLAN AREA E

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

18 19 20 21

D

L

K

G

C

A

B

F

E

M

H

M

A

TC

H L

IN

E

S E

E

TOILET

1404A

CHANGING

LOCKER

ROOM

AIRLOCK

CORROSION

CONTROL

CENTER

PAINT

BOOTH

BLAST

BOOTH

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:47:41 PM

6/

/ 2

8:

:4

P

M

IN116

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

6P

N

IN

TE

R

IO

R S

G R

O U

N D

F L O

O R

F

IN

IS

H

P

LA

N

AR

EA

F

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1

GROUND FLOOR FINISH

PLAN AREA F

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

CG1CG1

CG1

CG1

CG1

CG1

CG1 CG1

CG1 CG1

CG1

CG1

CG1

CG1

CG1

WP1

PT-3

PT

-2

PT

-2

PT

-2

PT

-2

PT

-2

PT

-2

PT

-2

PT

-2

PT

-2PT

-2

PT

-2

PT

-3

PT-3

PT-3

PT-3

PT

-3

CG1

CG1

PT-2

PT-3PL-2

CG1

PWT-2 & 3

PT-3

IN503

F1CG1

CG1 CG1

CG1

7 9 10 128 11

J

D

L

K

G

C

B

F

E

M

H

13' - 2 9/32"

4020.33

13' - 0"

3962.40

PT

-2

PT

-2

CAFE

SIPR

TELECOM

MNGR

OFFICE

ASST

MNGR

STAIR

ELECTRICAL

ROOM

OFFICE

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE

ROOM

CONFERENCE

ROOM

STAIR

GOVERNMENT

STAFF

CONFERENCE

ROOM

CONFERENCE

ROOM

STORAGE

STORAGE

MEN

JAN

2109WOMEN

OPEN

OFFICE

OPEN

OFFICE

RECEPTION

VESTIBULE

2.10

2.10

2.2

2.0

2.11

PFS - PAINTED

FLOORING SYSTEM

PFT -1 - PORCELAIN

FLOOR TILE

FLOORING FINISH LEGEND

PFT-2 - PORCELAIN

FLOOR TILE ACCENT

CS- CONCRETE

SEALER

ST-1 - TILE - STAIR

LANDING, RISE, AND

TREAD

EF-1

ENTRY MAT

BID OPTION #1

BID OPTION #2

BID OPTION #3

BID OPTION #4

BID OPTION #5

1.3

BID OPTION NUMBER

BID OPTION NOTE

(SUCCESSIVE)

BID OPTION KEYNOTE

BID OPTION LEGEND

GREY FILL INDICATES AREA OF BID OPTION

GRAPHIC SCALE

PLAN NORTH

1:100

10m2m 8m6m4m0m

DIM. NOTE & NORTH

KEY PLAN

1 21

M

A

C

A B C D FE

L

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:48:36 PM

6/

/ 2

8:

:3

P

M

IN123

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

3P

N

IN

TE

R

IO

R S

FI

R

ST

F

LO

O

R F

IN

IS

H P

LA

N

AR

EA

C

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 100A1 FIRST FLOOR FINISH PLAN AREA C

GENERAL SHEET NOTES

1. PATTERN AND COLOR IS IDENTIFIED FOR REFERENCE ONLY; ANY OTHER

MANUFACTURER'S SIMILAR PATTERN AND COLOR MAY BE SUBMITTED SUBJECT

TO APPROVAL BY THE CONTRACTING OFFICER.

2. REFER TO THE FINISH SCHEDULE FOR FINISH SELECTIONS IN EACH ROOM.

3. REFER TO THE COLOR MATERIALS LEGEND FOR FINISH ABBREVIATIONS AND

BASIS OF DESIGN.

4. PAINT ALL DOOR FRAMES PT-5.

5. PAINT ALL METAL DOORS PT-5.

6. ALL VENTS/ ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE.

USE ACRYLIC/SEMIGLOSS FINISH.

7. COLUMNS AND GALVANIZED BREAK METAL TRIM TO BE PAINTED TO MATCH

ADJACENT WALL SURFACE, U.N.O.

8. PAINT ALL WALLS PT-1, U.N.O.

9. PAINT GYP. CEILING PT-6, U.N.O.

10. RAILINGS, STRINGERS, AND RISERS TO BE PAINTED PT-8.

11. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH,

UNO.

12. REFERENCE INTERIOR ELEVATIONS FOR TYPICAL TILE WALL PATTERNS.

13. ALL EXTERIOR WINDOWS TO RECEIVE WT-1 U.N.O.

14. WHERE FLOOR FINISHES CHANGE BETWEEN ROOMS, PROVIDE THE

TRANSITION BENEATH THE DOOR LEAF IN THE CLOSED POSITION.

15. SEE SHEET IN-501 FOR TRANSITION DETAILS.

16. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

17. THE UNDERSIDE OF ALL SOFFITS TO BE PAINTED PT-6. THE FACE OF ALL

SOFFITS TO BE PAINTED PT-1, U.N.O. REFER TO REFLECTED CEILING PLANS

FOR SOFFIT LOCATIONS.

18. REFER TO SHEET IN-501 FOR WALL PROTECTION (CG1, CG2, WP1) DETAILS.

19. CENTER FLOOR TILE PATTERNS IN ROOM U.N.O.

20. REFER TO ARCHITECTURAL LIFE SAFETY PLANS FOR EGRESS PATHWAYS IN

SERVICE BAY AREAS.

KEYNOTES

18 OPERABLE PARTITION.

SEE SHEET A-IN602 FOR

INFORMATION.

FOR BID OPTION KEYNOTES REFER TO BID

OPTION LEGEND ON APPLICABLE DRAWINGS

2'

3.

2'

0"

9.

2'

6"

2.

2' - 6"

762.00

3' - 0"

914.40

3' - 3"

990.60

2' - 6"

762.00

PL-1

CWT-1

CWT-2

SS-1

PL-1

CWT-1

BASE AS

SCHEDULED

A6

IN502

A3

IN502

C1

IN502

MW1 MW1

CO1

FILLER PANEL

2' - 6"

762.00

3' - 0"

914.40

3' - 3"

990.60

2' - 6"

762.00

FILLER PANEL

0' - 1 187/256" 44.00

2' - 0"

609.60

2' - 0"

609.60

1' - 9"

533.40

1' - 9"

533.40

2' - 0"

609.60

2' - 0"

609.60 0' - 2" 50.80

M3M1

PR1PR1PL-1

BASE AS

SCHEDULED

SS-1

2'

3.

A1

IN502

FILLER

PANEL

3' - 6"

1066.80

3' - 6"

1066.80

R4 R3PR2 PR1 PR1

SS-1

PL-1

BASE AS SCHEDULED

2'

3.

A1

IN502

FILLER PANEL

PTB-1

PWT-1

PWT-2

PWT-1

0'

6 "

2.

4'

0 "

.2

0'

6 "

2.

9'

0 "

.2

TT-1

TT-1

3'

0"

4.

0'

6"

2.

3' - 2"

965.20

E1

IN502

E1

IN502

3'

0"

4.

0'

6"

2.

PL-1

BASE AS SCHEDULED.

SS-1

CAMP ARIFJAN SEAL

EQ

EQ

EQ EQ

1'

0"

4.

ADJUSTABLE

SHELF

CHAIN OF COMMAND

IG502

D7

OPEN TO BEYOND

PT-3

4'

4"

.8

0'

4"

1.

2'

0"

9.

PTB-2

PWT-3

PWT-2

PWT-3

PWT-2

PWT-3

TT-1

TT-1

TT-1

0'

4 "

1.

2'

0 "

9.

0'

4 "

1.

2'

0 "

9.

PTB-2

PWT-3

PWT-2

PWT-3

PWT-2

PWT-3

TT-1

TT-1

TT-1

0'

4"

1.

4'

4"

.8

PTB-2

PWT-3

PWT-2

PWT-3

PWT-2

PWT-3

TT-1

TT-1

TT-1

2'

0"

9.

EQ EQ

A6

IN502

A3

IN502

2' - 6"

762.00

3' - 3"

990.60

3' - 0"

914.40

2' - 6"

762.00

2'

6"

2.

2'

0"

9.

2'

3.

PL-1

CWT-1

CWT-2

SS-1

PL-1

CWT-1

BASE AS

SCHEDULED

2'

3.

C1

IN502

MW1

CO1CO1

MW1

FILLER PANEL

PTB-1

PWT-1

PWT-2

PWT-1

TT-1

TT-1

MIRROR

PL-1

SS-1

E3

IN502

GRAIN DIRECTION

PTB-1

PWT-1

PWT-2

PWT-1

TT-1

TT-1

MIRROR

PL-1

SS-1

E3

IN502

GRAIN

PTB-1

PWT-1

PWT-2

PWT-1

TT-1

TT-1

MIRROR

PL-1

SS-1

E3

IN502

GRAIN

PTB-1

PWT-1

PWT-2

PWT-1

TT-1

TT-1

MIRROR

PL-1

SS-1

E3

IN502

GRAIN

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:50:19 PM

6/

/ 2

8:

:2

P

M

IN210

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

0E

L

IN

TE

R

IO

R S

I N

TE

R

IO

R E

LE

V A

TI

O

N S

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 50A1 EAST ELEVATION @ CAFE 2110

1 : 50C7

WEST ELEVATION @ GOVERNMENT STAFF

1 : 50A4 EAST ELEVATION @ OPEN OFFICE 2102

1 : 50C4

TYPICAL WALL TILE ELEVATION @

RESTROOM

1 : 50D7 NORTH ELEVATION @ LOBBY 1601

1 : 50C1 SOUTH ELEVATION @ LOBBY 1601

1 : 50D1 EAST ELEVATION @ LOBBY 1601

1 : 50D4 SOUTH ELEVATION @ VEST. 2100

1 : 50A7 EAST ELEVATION @ BREAK ROOM 1616A

1 : 50F4 SOUTH ELEVATION @ MEN 1608A

1 : 50F9

SOUTH ELEVATION

@ WOMEN 2108

1 : 50F1 SOUTH ELEVATION @ WOMEN 1607A

1 : 50F7

NORTH ELEVATION @

MEN 2107

CG1

CG2

CG1 = 96" (2438.4MM) AFF

CG2 = 96" (2438.4MM)AFF

0'

1/

2"

.9

0' - 3 1/2"

88.90

0'

2 "

.8

PLASTIC CORNER GUARD

STAINLESS STEEL CORNER GUARD

CG1

PLASTIC CORNER GUARD

CG2 = 96" (2438.4MM) AFF

0'

2 "

.8

WP-1

.6 M

M 4'

6'

FACE OF SCHEDULED PARTITION

SCHEDULED BASE

IMPACT RESISTANT SHEET WALL

COVERING APPLIED ON TOP OF BASE

PROVIDE J-MOLDING AT EXPOSED

TOP AND SIDE EDGES.

CONCRETE FLOOR SLAB

SATIN ANODIZED ALUMINUM

TRANSITION STRIP

(SCHLUTER - RENO-U)

TS - 1 TRANSITION STRIP FROM PFT TO CS

CONCRETE FLOOR SLAB

ANODIZED ALUMINUM

TRANSITION STRIP

(SCHLUTER - RENO-T)

TS -4 TRANSITION STRIP FROM PFT TO PFT

TS - 3 TRANSITION STRIP FROM PFS TO CS

TS - 2 TRANSITION STRIP FROM PFS TO PFT

CONCRETE FLOOR SLAB

CONCRETE FLOOR SLAB

SATIN ANODIZED ALUMINUM

TRANSITION STRIP

(SCHLUTER - DECO)

SATIN ANODIZED ALUMINUM

TRANSITION STRIP

(SCHLUTER - RENO-RAMP)

CONCRETE

FLOOR SLAB

ANODIZED ALUMINUM

TRANSITION STRIP

(SCHLUTER - RENO-V)

9MM/8MM

TS - 5 TRANSITION STRIP FROM PFT TO ST OR PFS TO ST

9MM 8MM 8MM 8MM

9MM

12.5MM

8MM 0MM 0MM

PORCELAIN WALL TILE AS SPECIFIED

SCHLUTER SYSTEMS, DECO-SG (SG

80 AE 12)

MORTAR BED AS REQUIRED

WALL AS SCHEDULED

GROUT AS SPECIFIED

GROUT AS SPECIFIED

PORCELAIN WALL TILE AS SPECIFIED

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W

N B

Y:

D E

S

IG

N E

D B

Y:

S U

B M

IT

TE

D B

Y:

S

IZ

E

C H

E C

K E

D B

Y:

A N

S I D

IS

S

U E

D A

TE

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M A

R K

D

ES

C R

IP

TI

O N

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

P

LO

T D

A

TE

FI

LE

N A

M E

D

U

LL

ES

C

O R

N

ER

P

AR

K

SU

IT

E

H

ER

N D

O N

, V A

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

, V A

-1

C

AM

P

AR

IF

JA

N , K

U W

AI

T

C

AR

E

AN

D P

R

ES

ER

VA

TI

O

N F

AC

IL

IT

Y

KU

W

AI

T W

2E

R -1

-D -0

C:\Users\schafea\Documents\KU-369882A-IN17_CH-JEG_april.schaferLRJQV.rvt

6/20/2019 8:50:55 PM

6/

/ 2

8:

:5

P

M

IN501

A.

S

C H

AF

ER

A.

S

C H

AF

ER

J.

B

R

AD

LE

Y

JU

N

E

A

M . P

R

AT

T

KU

-3

A-

IN

1D

T

IN

TE

R

IO

R S

IN

TE

R

IO

R D

E T

AI

LS

RTA

0%

D

ES

IG

N

SU

BM

IT

TA

L

/2

1/

1 : 4A1 DETAIL @ CORNER GUARDS

1 : 4A3 DETAIL @ SHEET WALL PROTECTION

1 : 1A6 TRANSITION STRIP DETAILS

1 : 1D3 DETAIL @ TILE TRIM

2X4 CONTINUOUS WITH 3/8" DIAMETER

WEDGE ANCHORS (TORQUE TEST PER

IR 26) AT 24" O.C. (2 1/2" MINIMUM

EMBEDMENT) USE #8 BUGLE HEAD

FINISHED FLOOR

2X WOOD FRAME

BASE AS SCHEDULED

OVER 3/4" PLYWOOD

NOTE: FLUSH OVERLAY

CONSTRUCTION

PLASTIC LAMINATE

ON 3/4" MDF BASE

CABINET DOOR -

PLASTIC LAMINATE

ON 3/4" MDF#8 X 1 1/2" BUGLE HEAD

SCREWS AT 12" O.C. MAXIMUM

#10 X 3" LONG

FHWS AT 12" O.C.

0' - 2 125/128"

75.58

0'

6"

2.

BASE - REFER TO ROOM

FINISH SCHEDULE

FINISH FLOOR

3/4" MDF WITH PLASTIC

LAMINATE FINISH

BASE CABINET BEYOND

SINK - REFER TO

PLUMBING

SOLID SURFACE APRON

SOLID SURFACE

AND BACKSPLASH

COUNTERTOP

CONTINUOUS

SEALANT, TYPICAL

PREFABRICATED

PLASTIC LAMINATE

UNDERSINK PROTECTIVE

ENCLOSURE. INSTALL

PER MANUFACTURER'S

RECOMMENDATIONS

0' - 0 1/2" 12.70

2' - 1"

635.00

2'

5"

6.

2'

7/

8"

3.

0'

5/

6"

1.

BOTTOM FINISH PLASTIC

LAMINATE

CABINET PULL, TYPICAL

CASE 3/4" WHITE PLASTIC

LAMINATE WITH PVC EDGEBAND

TO MATCH

WOOD BLOCKING TYP, AS

REQUIRED. REFER TO

C9/IN502

PLASTIC LAMINATE DOOR

1' - 0 207/256"

325.31

1'

6"

7.

3'

0"

4.

2'

3.

24" MAX FOR SIDE REACH

4" WIRE CABINET PULL.

BRUSHED CHROME

FINISH.

D…

This is the start of the file's text. The full file is on GovTribe.