Amendment 0003 Plans.pdf

PDF 220 KB Posted

Attached to
Mill Creek Low Flow Radial Arm Gate Repair
Solicitation number
W912EF21B0012
Issued by

About this file

This document provides details on an upcoming federal construction solicitation. The U.S. Army Corps of Engineers Walla Walla District will issue an Invitation for Bids for repairs to the Mill Creek Low Flow Radial Arm Gate. The scope of work includes concrete excavation and repair, abrasive blasting and coating of hydraulic steel structures, removal and replacement of bearings, and fabrication and installation of a radial gate control panel with a PLC control system to modulate gate position based on forebay water level. The contractor will be responsible for safety compliance and submittals. This procurement is set aside for small businesses with a size standard of $39.5 million. The estimated value is between $100,000 and $250,000. The solicitation will be posted on sam.gov in late May 2021 with a public bid opening approximately 30 days later. The low bidder must submit responsibility criteria according to FAR Subpart 9.1. Payment and performance bonds are required.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

/2

/2

C H

A N

G E

S T

O K

E Y

N O

T E

A

N S

I D

F

IL

E N

O

M A

R C

H

M C

-1 -1

/9

W

E F

B

DS: PD: AEC_pdf.pltcfg1:32:08 PM 6/23/2021

...\...\MC485876\...\MC485876MD101XXX.dgn

W A

L L

A W

A L

L A

D

IS

T R

IC

T

IN

T

A K

E C

A N

A L

H E

A D

W O

R K

S

M

IL

L C

R E

E K

F L

O O

D C

O N

T R

O L

P R

O J E

C T

W A

L L

A W

A L

L A

W

A S

H

IN

G T

O N

D

IV

E R

S

IO

N D

A M

R A

D

IA

L A

R M

G A

T E

R E

P A

IR

S

C

B R

E N

N E

IS

E

J H

A U

G E

N

MD101

K E

V

IN

R E

N S

H A

W

P .E

W A

L L

A W

A L

L A

W

A S

H

IN

G T

O N

N

R

D A

V E

FINAL

P

A U

T H

M E

C H

A N

IC

A

L D

E M

O L

IT

IO

N P

L A

N S

A1

SCALE: 3/4" = 1'

A6

PARTIAL PLAN: NORTH GATE WELL LIFTING GEAR REMOVAL

SCALE: 3/4" = 1'

PARTIAL PLAN: NORTH GATE WELL TRUNNION BEARING REMOVAL

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

S I Z

E

S U

B M

IT

T

E D

B Y

D A

T E

C O

N T

R A

C T

N O

C

H E

C K

E D

B Y

D R

A W

N B

Y

IS

S

U E

D A

T E

SHEET ID

A

B

C

D

E

F

G

1 98765432

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

HOISTING CABLE

EXISTING GATE

EXISTING CONCRETE PEDESTAL

END BEARING HOUSING

EXISTING SHAFT

EXISTING CABLE DRUMS

HOISTING CABLE

EXISTING GATE

BEARING BASE BELOW GRATING

EXISTING TRUNNION

FOREBAY

SOUTH GATE WELL

FLANGED HALF COUPLING

REMOVE EXISTING

ESCUTCHEON PLATES

FLOATING

CABLE OPENING

EXISTING GATE LIFTING

BELOW GRATING

BEARING BASE

EXISTING TRUNNION

SOUTH GATE WELL

SHEET KEYNOTES

G-102

REF

2'0 1' 4' G-102

REF

NORTH

PLAN

NORTH

PLAN

2'0 1' 4'

GRATING.

REMOVE EXISTING BEARING HOUSING WITH RADIAL ARM GATE BELOW

REBUILD THE EXISTING TRUNNION BEARINGS: 7.

REMOVE AND SET ASIDE FOR REINSTALLATION.6.

BEARING REMOVAL USING LINE BORE AND LINE WELD METHODS.

INSIDE SURFACES OF THE BUSHING HOUSING BARRELS DONE DURING

OUT OF THE THE BUSHING HOUSING BARRELS. REPAIR DAMAGE TO THE

GATE FROM THE SOUTH GATE WELL. CUT THE EXISTING BRONZE BUSHINGS

THE BUSHING HOUSING BARRELS OF THE TRUNNION ARMS ON THE EXISTING

REMOVE THE EXISTING PRESS FIT BRONZE BUSHINGS FROM THE INSIDE OF 5.

SOUTH GATE WELL.

REMOVE EXISTING TRUNNION BASES FROM EXISTING GATE FROM THE 4.

EXISTING COATING PRIMER CONTAINS LEAD.

SYSTEM SHALL BE AS SPECIFIED FOR "PAINTING: HYDRAULIC STRUCTURES."

BEARING BASE AND LIFTING GEAR. CLEANING, PREPARATION, AND COATING

3. CLEAN, PREPARE, AND COAT EXTERIOR SURFACES OF THE TRUNNION

NORTH GATE WELL.

SOUTH GATE WELL IS A MIRROR IMAGE OF THE WORM GEAR FROM THE

SEALS AND OTHER COMPONENTS. THE WORM GEAR REDUCER FROM THE

GATE WELL) TO DETERMINE APPROXIMATE DIMENSIONS FOR ORDERING

SOUTH GATE WELL (LOCATED NEAR THE EXISTING GATE FROM THE SOUTH

THE DIMENSIONS OF THE EXISTING WORM GEAR REDUCER FROM THE

BY THE MANUFACTURER, GASKETS, AND SHAFT SEALS IF NECESSARY. USE

REDUCERS: INSPECT GEAR BOX, PROVIDE GEAR OIL THAT IS RECOMMENDED

GASKETS AND REMOVE SEALS. REFURBISH EXISTING WORM GEAR

DRAIN GEAR OIL FROM EXISTING WORM GEAR REDUCER BOX, REMOVE 2.

REMOVE AND SET ASIDE FOR REPAIR AND REINSTALLATION.1.

NORTH GATE WELL

EXISTING GRATING 6

1 4

HOIST DRUM SHAFT

EXISTING GATE

CONCRETE

EDGE OF

HANDRAIL

EXISTING

SHIPPING DATE: "10/21/40"

"OUR LUBRICANT NO.: 4"

SERIAL NO: E85441A

RATIO: 80 TO 1

TYPE: 25 WT

EXISTING "FOOTE BROS" WORM GEAR SPEED REDUCER,

NORTH GATE WELL

File details come from the government source that posted it. Updated .