Site_Visit_Slides_10-17-2019.pdf

PDF 580 KB Posted

Attached to
Information Systems Facility, Joint Base Lewis-McChord (JBLM), WA Federal contract opportunity
Solicitation number
W912DW19R0025
Issued by
Department of the Army Corps of Engineers Engineering District Seattle

About this file

This document provides details on a forthcoming federal contract opportunity for the construction of an Information Systems Facility at Joint Base Lewis-McChord in Washington state. The solicitation will request the construction of a new 44,832 square foot facility including administrative offices, open office space, meeting rooms, and technical spaces for equipment testing, telecommunications infrastructure, and secure spaces. Supporting facilities will include site development, utilities, parking, and landscaping. Construction is estimated between $25-100 million. The solicitation will utilize a two-part bifurcated process, initially requesting technical proposals and later price proposals from qualifying offerors. The solicitation number is W912DW19R0025 and will be available on September 26, 2019 on FBO.gov. Proposals will be due no sooner than 30 days after issue. The NAICS code is 236220 and it is unrestricted. The point of contact for questions is John Scola by email.

Site Visit Slides

View the file

Other files for this federal contract opportunity

Other files attached to Information Systems Facility, Joint Base Lewis-McChord (JBLM), WA, newest first.
File Type Posted
Site_Visit_Roster_Sheet_10-17-2019.pdf PDF
Amendment_R0001.pdf PDF
ISF_Watermarked_Specs.pdf PDF
RFP_W912DW19R0025.pdf PDF
ISF_Watermarked_Specs.pdf PDF
ISF_Drawings_VOL_I.pdf PDF
Attachment_1.docx DOCX document
ISF_Drawings_VOL_III.pdf PDF
ISF_Drawings_VOL_II.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10/16/2019

US Army Corps of Engineers

BUILDING STRONG®

Site Visit

John Scola/John Dudgeon

USACE Seattle District

17 October 2019

BUILDING STRONG®

Request for Proposal (RFP)

W912DW19R0025

Information System Facility at JBLM, WA

BUILDING STRONG®

Introduction

The slides from this site visit will be posted to the FBO.gov.

This site visit is for informational purposes only.

Comments/clarifications made today WILL NOT change the RFP in any way.

Changes to the RFP shall ONLY be made by written Amendments.

3 BUILDING STRONG®

Site Visit Questions Any and all questions from this Site Visit should be submitted to www.ProjNet.org using the Bidder Inquiry Key and instructions provided in the RFP.

No technical-specific questions will be answered today.

Instead, all questions should be asked on www.ProjNet.org.

The deadline for submitting questions in www.ProjNet.org is three (3) business days prior to the proposal due date.

BUILDING STRONG®

Questions During Proposal Stage

Contracting Web Address for RFP Documents:

www.FBO.gov.

Search for RFP Number:

► W912DW19R0025

Technical Questions: www.ProjNet.org For Any Other Administrative Questions, please contact

John Scola (Contract Specialist) at:

► Email: John.P.Scola@usace.army.mil

Federal Acquisition Regulation: https://acquisition.gov

5 BUILDING STRONG®

UNRESTRICTED

Responses to this RFP will be Unrestricted – open to both large and small businesses.

NAICS Code is 236220.

For specific small business related questions, please contact the Deputy for Small Business Programs at:

► Email: John.S.Solomon@usace.army.mil

BUILDING STRONG®

RFP

General Information

RFP NUMBER: W912DW19R0025

This RFP is a Bifurcated, Design Bid Build (DBB), Trade- Off procurement.

Amendments will be issued when changes to RFP is necessary.

Magnitude of Construction is estimated between $25M to $100M.

Bid Guarantee is required in the amount of 20% of the Price or $3M, whichever is less.

► Please see FAR 52.228-1 for more details.

7 BUILDING STRONG®

RFP

General Information, continued Please see 00 21 00, 00 22 00 and Bifurcated Sections for required documents to be included with your proposal submittals for Part One and Part Two.

Your Part One “Technical proposal” is due at the U.S.

Army Corps of Engineers, Seattle District Office, no later than 1:00:00 PM (Seattle Time), on 29 October 2019.

► Please refer to Block 13 on SF 1442.

NO offers will be accepted after the noted time and date.

PLEASE DO NOT BE LATE.

BUILDING STRONG®

RFP

General Information

Read descriptions of all evaluation factors thoroughly.

Ensure your proposal is complete and reflects all elements required by the RFP.

Part One:

► Volume 1 - Factor 1, 2 and 3.

Part Two:

► Volume 2 - Factor 4 and Subcontracting Plan (if applicable)

► Volume 3 – Factor 5

(See Bifurcated Section for Details)

9 BUILDING STRONG®

Conclusion Part One: Continue to check FBO.gov for new

Amendments to the RFP. Check regularly up until the due date and time for receipt of Part One Technical proposals.

Part Two: Continue to check your emails for RFP Amendments.

Ensure you have completed ALL information required by the RFP and submit those items with your Proposals.

Ensure compliance with the RFP requirements.

This RFP shall ONLY be changed by written Amendment.

The Government intends to award on initial offers, to the Proposal which offers the Best Value to the Government.

BUILDING STRONG®

Site Visit Information

USACE POC: John Dudgeon

File details come from the government source that posted it. Updated .