18R0004_NZAS173001_MMDF_Drawings_-_Part_3_of_3.pdf
PDF 30 MB Posted
- Solicitation number
- W912DW18R0004
About this file
Plans Part 3 of 3 W912DW18R0004 MMDF MAFB
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VEHICLE
BAYS
M A
T C
H L
IN
E
R E
F E
R
F P
M A
T C
H L
IN
E
R E
F E
R
F P
M A
T C
H L
IN
E
R E
F E
R
F P
MATCHLINE
REFER 1 FP111
4.9
7.1
5.5
6.5
A B C D E
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2"
2 1/2"
2 1/2"
2 1/2"
2 1/2"
2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 2"
TYPICAL
10' - 2"
OH
[21' 7.5"]
[21'10.5"]
[23' 3.5"]
[24' 9"]
[26' 2.5"]
[26' 4"]
VEHICLE
BAYS
OH
[24' 9"]
[23' 3"]
[21' 8.5"]
[21' 6"] [21' 6"]
6"
6"
2' - 8"
TYPICAL
2' - 8" 4' - 0"
3' - 1"
SPRIG
1" x 1'-9"
TYP.
SPRIG
1" x 1'-9"
TYP.
SPRIG
1" x 2'-0"
TYP.
SPRIG
1" x 1'-8"
TYP.[26' 0"]
SPRIG
1" x 1'-10"
TYP.
SPRIG
1" x 1'-10"
TYP.
SPRIG
1" x 1'-9"
TYP.
SPRIG
1" x 1'-9"
TYP.
SPRIG
1" x 1'-8"
TYP.
SPRIG
1" x 1'-8"
TYP.
SPRIG
1" x 1'-11"
TYP.
SPRIG
1" x 1'-11"
TYP.
SPRINKLER SYSTEM DESIGN CRITERIA
PATTERN SYSTEM TYPE/
OCCUPANCY
MINIMUM
SPRINKLER
DENSIT/AREA
HOSE
STREAM
ALLOWANCE/
DURATION
SPRINKLER
K-FACTOR
WET-PIPE
SYSTEM:
LIGHT
HAZARD
0.10 GPM/SF
OVER MOST
REMOTE
1,500 SF
250 GPM
FOR 60
MINUTES
5.6
WET-PIPE
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
8.0
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
NFPA 13
FIGURE
16.2.1.3.2
(D) CURVE
E AND
FIGURE
16.2.1.3.4.1.
0.624 GPM/SF
OVER THE
MOST
REMOTE
2,000 SF
500 GPM
FOR 120
MINUTES
11.2 (HIGH
TEMP)
ROOMS/AREAS
PROTECTED
OFFICE,
RESTROOMS,
TRAINING,
SUPERVISOR
ROOMS, BRIEF
ROOMS, BREAK
ROOM
COMM ROOMS,
STORAGE, IT,
MECH/ELEC
ROOMS,
JANITOR'S
CLOSET, SHOPS,
AND TELECOM
ROOMS
CLASS IV NON-
ENCAPSULATE
D STORAGE UP
TO 22 FEET IN
HEIGHT ON
RACKS WITH 8
FOOT AISLES
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
VEHICLE
MAINTENANCE
BAYS
8.0
OH
OH
ST
LH
SPRINKLER LEGEND
TYPE SYMBOL SIZE TEMP K-FACTOR FINISH
QUICK RESPONSE
PENDENT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
PENDENT
1/2"
3/4"
1/2"
1/2"
8.0
11.2
5.6
8.0
BRASS
BRASS
BRASS
BRASS
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
B
AREA B
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:1 :4
P
M
D B
A R
B E
R
B B
O O
N E
FP112
R P
A R
K
F I R
E S
P R
IN
K
L E
R P
L A
N
A
R E
A B
N Z
A S
F
P
SCALE 1/8" = 1'-0"
PARTIAL FIRE SPRINKLER PLAN AREA B
GENERAL NOTES - FIRE SPRINKLER
A REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS
AND GENERAL NOTES.
B REFER TO SHEET F-501 AND F-502 FOR FIRE SPRINKLER
DETAILS.
C REFER TO SHEET F-503 FOR FIRE RISER DETAILS.
D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR COORDINATION WITH LIGHTS, MECHANICAL
DIFFUSERS, AND CEILING GRID.
KEYNOTES
117 REFER TO FP100 FOR CONTINUATION OF ZONE B SINGLE
INTERLOCK PREACTION SYSTEM MAIN.
138 SUGGESTED ROUTING FOR ZONE E-WEST WET PIPE
SPRINKLER SYSTEM MAIN.
VES
STORAGE
NEC
STORAGE
RECOVERY
M A
T C
H L
IN
E
R E
F E
R
F P
MATCHLINE
REFER 1 FP114
MATCHLINE
REFER 1 FP115
MATCHLINE
REFER 1 FP111
M A
T C
H L
IN
E
R E
F E
R
F P
M A
T C
H L
IN
E
R E
F E
R
F P
M A
T C
H L
IN
E
R E
F E
R
F P
MATCHLINE
REFER 1 FP111
4.9
7.1
5.5
6.5
E F G H JH.2E.8E.6 F-502
F-502
1'-0"
4" 4"4"4"4"4"4"4"4"4"4"
1'-0"
TYPICAL
4' - 0"
TYPICAL
9' - 1"
TYPICAL
9' - 2"
TYPICAL
9' - 4"
TYPICAL
9' - 11"
TYPICAL
10' - 1"
TYPICAL
10' - 0"
TYPICAL
10' - 1"
TYPICAL
9' - 11"
TYPICAL
10' - 2"
TYPICAL
9' - 1"
TYPICAL
9' - 3"
TYPICAL
9' - 1"
1'-0"
ST
STST
[24' 5"]
[24' 11"]
[25' 6"]
[25' 8"]
[26' 6"]
[27' 4"]
[27' 4"]
[26' 6"]
[25' 8"]
[24' 10"]
[24' 1"]
[23' 3"]
[22' 5"] [22' 8.5"]
[23' 6"]
[24' 3"]
[25' 0"]
[25' 11"]
[26' 9"]
[27' 7"]
[27' 6"]
[26' 8"]
[25' 10"]
[25' 0"]
[24' 3"]
[22' 4"]
[21' 7.5"]
[22' 5"]
[22' 7"]
22' 3"]
4" 4" 4" 4" 4"
4"4"4"4"4"
4" 4" 4" 4" 4"
4"4"4"4"4"
4"
4" 4" 4" 4" 4"
4"4"4"4"
4" 4" 4" 4"4" 4"
4"4"4"4" 4" 4"
4" 4" 4" 4" 4" 4"
4"4"4"4"4"4"
4" 4" 4"
4"
4" 4"
4"
4"4"4"
4" 4" 4" 4"
4"4"4"4"
4"
4" 4" 4" 4" 4" 4"
4"4"4"4"4"4"
4" 4" 4" 4" 4"
4"4"4"4"4"
4"
4"
4" 4" 4" 4" 4"
4"4"4"4"
4" 4" 4" 4"
1'-0"
12"
4" 4" 4" 4" 4"
[22' 5"]
4' - 3"
117 118
SPRIG
1'-7" TYP.
SPRIG
1'-10" TYP.
SPRIG
0'-10" TYP.
SPRIG
0'-10" TYP.
SPRIG
0'-9" TYP.
SPRIG
0'-10" TYP.
SPRIG
0'-10" TYP.
SPRIG
0'-8" TYP.
SPRIG
0'-8" TYP.
SPRIG
0'-8" TYP.
SPRIG
0'-10" TYP.
SPRIG
0'-9" TYP.
SPRIG
0'-8" TYP.
SPRIG
0'-8" TYP.
SPRIG
0'-9" TYP.
4" 4" 4" 4"
4" 4" 4"
4"4"4"4"4"4"
4" 4" 4"
4"
SPRIG
0'-5" TYP.
SPRIG
0'-6" TYP.
SPRIG
0'-4" TYP.
SPRIG
0'-11" TYP.
SPRIG
1'-0" TYP.
SPRIG
1'-0" TYP.
SPRIG
0'-11" TYP.
SPRIG
0'-11" TYP.
SPRIG
0'-11" TYP.
SPRIG
1'-0" TYP.
SPRIG
0'-11" TYP.
SPRIG
0'-11" TYP.
SPRIG
1'-0" TYP.
1'-0"
SPRINKLER SYSTEM DESIGN CRITERIA
PATTERN SYSTEM TYPE/
OCCUPANCY
MINIMUM
SPRINKLER
DENSIT/AREA
HOSE
STREAM
ALLOWANCE/
DURATION
SPRINKLER
K-FACTOR
WET-PIPE
SYSTEM:
LIGHT
HAZARD
0.10 GPM/SF
OVER MOST
REMOTE
1,500 SF
250 GPM
FOR 60
MINUTES
5.6
WET-PIPE
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
8.0
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
NFPA 13
FIGURE
16.2.1.3.2
(D) CURVE
E AND
FIGURE
16.2.1.3.4.1.
0.624 GPM/SF
OVER THE
MOST
REMOTE
2,000 SF
500 GPM
FOR 120
MINUTES
11.2 (HIGH
TEMP)
ROOMS/AREAS
PROTECTED
OFFICE,
RESTROOMS,
TRAINING,
SUPERVISOR
ROOMS, BRIEF
ROOMS, BREAK
ROOM
COMM ROOMS,
STORAGE, IT,
MECH/ELEC
ROOMS,
JANITOR'S
CLOSET, SHOPS,
AND TELECOM
ROOMS
CLASS IV NON-
ENCAPSULATE
D STORAGE UP
TO 22 FEET IN
HEIGHT ON
RACKS WITH 8
FOOT AISLES
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
VEHICLE
MAINTENANCE
BAYS
8.0
OH
OH
ST
LH
SPRINKLER LEGEND
TYPE SYMBOL SIZE TEMP K-FACTOR FINISH
QUICK RESPONSE
PENDENT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
PENDENT
1/2"
3/4"
1/2"
1/2"
8.0
11.2
5.6
8.0
BRASS
BRASS
BRASS
BRASS
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
C
AREA C
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:1 :5
P
M
D B
A R
B E
R
B B
O O
N E
FP113
R P
A R
K
F I R
E S
P R
IN
K
L E
R P
L A
N A
R E
A C
N Z
A S
F
P
GENERAL NOTES - FIRE SPRINKLER
A REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS
AND GENERAL NOTES.
B REFER TO SHEET F-501 AND F-502 FOR FIRE SPRINKLER
DETAILS.
C REFER TO SHEET F-503 FOR FIRE RISER DETAILS.
D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR COORDINATION WITH LIGHTS, MECHANICAL
DIFFUSERS, AND CEILING GRID.
KEYNOTES
101 FOR SPRINKLER PROTECTION UNDER MEZZANINE, SEE
VIEW 2 ON THIS SHEET.
117 REFER TO FP100 FOR CONTINUATION OF ZONE B SINGLE
INTERLOCK PREACTION SYSTEM MAIN.
118 REFER TO FP100 FOR CONTINUATION OF ZONE D SINGLE
INTERLOCK PREACTION SYSTEM MAIN.
133 SUGGESTED ROUTING FOR ZONE C SINGLE-INTERLOCK
PREACTION SPRINKLER SYSTEM MAIN.
137 REFER TO 2/F-502 FOR CONNECTION TO SPRINKLERS
PROTECTING AREA BELOW THE MEZZANINE.
VEHICLE
BAYS
M A
T C
H L
IN
E
R E
F E
R
F P
M A
T C
H L
IN
E
R E
F E
R
F P
M A
T C
H L
IN
E
R E
F E
R
F P
M A
T C
H L
IN
E
R E
F E
R
F P
4.9
7.1
5.5
6.5
J K L M N
6"
6"
6"6"
2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2"2 1/2"2 1/2"
2 1/2" 2 1/2"2 1/2"2 1/2"
2 1/2" 2 1/2"2 1/2"2 1/2"
2 1/2" 2 1/2"2 1/2"2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2"2 1/2"2 1/2"
2 1/2"2 1/2"2 1/2"2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2"2 1/2"2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2"2 1/2"2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2" 2 1/2" 2 1/2" 2 1/2"
2 1/2"2 1/2"2 1/2"2 1/2"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
TYPICAL
10' - 0"
86' - 0"
OH
[18' 9"]
[22' 9"]
[21' 8"]
[23' 3"]
[24' 9"]
[26' 3"]
[26' 3.5"]
[24' 9"]
[23' 3"]
[20' 1"]
TYPICAL
6' - 1"
TYPICAL
10' - 0"
RN 1.5" x 2'-11"
RN 1.5" x 3'-0"
[20' 3"]
[21' 10"]
[23' 2.5"]
[23' 0"]
[21' 7"]
[20' 3"]
[19' 0"]
RN 1.5" x 3'-0"
RN 1.5" x 3'-1"
RN 1.5" x 3'-3"
RN 1.5" x 3'-2"
RN 1.5" x 3'-0"
RN 1.5" x 1'-1"
RN 1.5" x 2'-11"
RN 1.5" x 3'-0"
RN 1.5" x 3'-0"
RN 1.5" x 3'-1"
RN 1.5" x 3'-3"
RN 1.5" x 3'-2"
RN 1.5" x 3'-0"
RN 1.5" x 1'-1"
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRIG
1" x 1'-9" TYP.
SPRINKLER SYSTEM DESIGN CRITERIA
PATTERN SYSTEM TYPE/
OCCUPANCY
MINIMUM
SPRINKLER
DENSIT/AREA
HOSE
STREAM
ALLOWANCE/
DURATION
SPRINKLER
K-FACTOR
WET-PIPE
SYSTEM:
LIGHT
HAZARD
0.10 GPM/SF
OVER MOST
REMOTE
1,500 SF
250 GPM
FOR 60
MINUTES
5.6
WET-PIPE
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
8.0
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
NFPA 13
FIGURE
16.2.1.3.2
(D) CURVE
E AND
FIGURE
16.2.1.3.4.1.
0.624 GPM/SF
OVER THE
MOST
REMOTE
2,000 SF
500 GPM
FOR 120
MINUTES
11.2 (HIGH
TEMP)
ROOMS/AREAS
PROTECTED
OFFICE,
RESTROOMS,
TRAINING,
SUPERVISOR
ROOMS, BRIEF
ROOMS, BREAK
ROOM
COMM ROOMS,
STORAGE, IT,
MECH/ELEC
ROOMS,
JANITOR'S
CLOSET, SHOPS,
AND TELECOM
ROOMS
CLASS IV NON-
ENCAPSULATE
D STORAGE UP
TO 22 FEET IN
HEIGHT ON
RACKS WITH 8
FOOT AISLES
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
VEHICLE
MAINTENANCE
BAYS
8.0
OH
OH
ST
LH
SPRINKLER LEGEND
TYPE SYMBOL SIZE TEMP K-FACTOR FINISH
QUICK RESPONSE
PENDENT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
PENDENT
1/2"
3/4"
1/2"
1/2"
8.0
11.2
5.6
8.0
BRASS
BRASS
BRASS
BRASS
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
D
AREA D
s /2
-1
-0
/1
/2
:1 :5
P
M
D B
A R
B E
R
B B
O O
N E
FP114
R P
A R
K
F I R
E S
P R
IN
K
L E
R P
L A
N A
R E
A D
N Z
A S
F
P
SCALE 1/8" = 1'-0"
PARTIAL FIRE SPRINKLER PLAN AREA D
GENERAL NOTES - FIRE SPRINKLER
A REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS
AND GENERAL NOTES.
B REFER TO SHEET F-501 AND F-502 FOR FIRE SPRINKLER
DETAILS.
C REFER TO SHEET F-503 FOR FIRE RISER DETAILS.
D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR COORDINATION WITH LIGHTS, MECHANICAL
DIFFUSERS, AND CEILING GRID.
KEYNOTES
101 FOR SPRINKLER PROTECTION UNDER MEZZANINE, SEE
VIEW 2 ON THIS SHEET.
118 REFER TO FP100 FOR CONTINUATION OF ZONE D SINGLE
INTERLOCK PREACTION SYSTEM MAIN.
134 SUGGESTED ROUTING FOR ZONE D SINGLE-INTERLOCK
PREACTION SPRINKLER SYSTEM MAIN.
MMT
TRAINING
ROOM
MMT TOOL
ROOM
MMT
SUPERVISOR
EMT TOOL
ROOM
EMT
TRAINING
ROOM
EMT
SUPERVISORS
LOADING
AREA
VEHICLE
BAYS
MATCHLINE
REFER 1 FP113
M A
T C
H L
IN
E
R E
F E
R
F P
MATCHLINE
REFER 1 FP114/
MATCHLINE
REFER 1 FP112
7.1
E F G H JH.2E.8E.6
2" 2" 2" 2"
2" 2" 2"
2"2"2" 2"
6"
2" 2" 2"
4" 4"
/2
/2
4" 4" 1
/2
/2
/2
2" 2" 2" 2"
2"2"2"2"
2" 2" 2" 2"
6"
2"
10' - 11" 10' - 11"
8' - 1" 8' - 10" 7' - 10"
8' - 6" 8' - 6" 8' - 6"
7' - 10" 9' - 0" 7' - 11"
OH
OH
OH
LH
LH
LH
OH
LH
2"2"
8' - 1" 8' - 10" 7' - 10"
8' - 1" 8' - 10" 7' - 10"
7' - 10" 9' - 0" 7' - 11"
7' - 10" 9' - 0" 7' - 11"
123 123
[16' 6"] [17' 9"] [18' 11"]
[19' 0"][19' 6"] [17' 10.5"] [16' 9"] [16' 3"]
[16' 3"]
[11' 1.5"]
[10' 7"] [16' 6"] [17' 9"] [18' 11"] [19' 0"] [17' 10.5"] [16' 9"]
[10' 7"]
[10' 7"]
[11' 1.5"]
[11' 1.5"]
4"4"4"4"
4" 4" 4" 4" 4"
6"
T Y
P
IC
A L
T Y
P
IC
A L
T Y
P
IC
A L
T Y
P
IC
A L
/2
/2
/2
/2
/2
/2
/2
/2
4' - 11" 8' - 6" 8' - 6"
/2
/2
/2
/2
/2
/2
/2
/2
/2
5' - 2"
6' - 3"
6' - 3"
5' - 8"
6' - 3"
6' - 2"
5' - 1"
4' - 11"
6"
5' - 7"
[16' 3"] [16' 3"]
[16' 3"]
138 139
135 135138 139 1
FP115
FP115
SPRIG
1" x 7"
SPRIG
1" x 7"
SPRIG
1" x 8"
SPRIG
1" x 6"
SPRIG
1" x 7"
SPRIG
1" x 9"
SPRIG
1" x 11"
DROP
1" x 9" TYP.
DROP
1" x 9" TYP.
DROP
1" x 9" TYP.
DROP
1" x 1'-4" TYP.
DROP
1" x 1'-4" TYP.
DROP
1" x 1'-4" TYP.
SPRIG
1" x 7"
SPRIG
1" x 6"
SPRIG
1" x 7"
SPRIG
1" x 9"
SPRIG
1" x 10"
10' - 2" 11' - 11"
SPRINKLER SYSTEM DESIGN CRITERIA
PATTERN SYSTEM TYPE/
OCCUPANCY
MINIMUM
SPRINKLER
DENSIT/AREA
HOSE
STREAM
ALLOWANCE/
DURATION
SPRINKLER
K-FACTOR
WET-PIPE
SYSTEM:
LIGHT
HAZARD
0.10 GPM/SF
OVER MOST
REMOTE
1,500 SF
250 GPM
FOR 60
MINUTES
5.6
WET-PIPE
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
8.0
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
NFPA 13
FIGURE
16.2.1.3.2
(D) CURVE
E AND
FIGURE
16.2.1.3.4.1.
0.624 GPM/SF
OVER THE
MOST
REMOTE
2,000 SF
500 GPM
FOR 120
MINUTES
11.2 (HIGH
TEMP)
ROOMS/AREAS
PROTECTED
OFFICE,
RESTROOMS,
TRAINING,
SUPERVISOR
ROOMS, BRIEF
ROOMS, BREAK
ROOM
COMM ROOMS,
STORAGE, IT,
MECH/ELEC
ROOMS,
JANITOR'S
CLOSET, SHOPS,
AND TELECOM
ROOMS
CLASS IV NON-
ENCAPSULATE
D STORAGE UP
TO 22 FEET IN
HEIGHT ON
RACKS WITH 8
FOOT AISLES
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
VEHICLE
MAINTENANCE
BAYS
8.0
OH
OH
ST
LH
SPRINKLER LEGEND
TYPE SYMBOL SIZE TEMP K-FACTOR FINISH
QUICK RESPONSE
PENDENT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
PENDENT
1/2"
3/4"
1/2"
1/2"
8.0
11.2
5.6
8.0
BRASS
BRASS
BRASS
BRASS
E.8E.6
A3
F-503
H H.2
A4
F-503
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
E
AREA E
s /2
-1
-0
/1
/2
:1 :0
P
M
D B
A R
B E
R
B B
O O
N E
FP115
R P
A R
K
F I R
E S
P R
IN
K
L E
R P
L A
N A
R E
A E
N Z
A S
F
P
SCALE 1/8" = 1'-0"
PARTIAL FIRE SPRINKLER PLAN AREA E
GENERAL NOTES - FIRE SPRINKLER
A REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS
AND GENERAL NOTES.
B REFER TO SHEET F-501 AND F-502 FOR FIRE SPRINKLER
DETAILS.
C REFER TO SHEET F-503 FOR FIRE RISER DETAILS.
D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR COORDINATION WITH LIGHTS, MECHANICAL
DIFFUSERS, AND CEILING GRID.
KEYNOTES
104 LOCATION OF FIRE LINE BUILDING ENTRY.
106 8 INCH UNDERGROUND FIRE LINE.
108 WALL-MOUNTED FIRE DEPARTMENT CONNECTION WITH
TWO 2-1/2-INCH INLETS. PROVIDE SIGNAGE (APPROVED
BY OWNER) INDICATING REQUIRED SYSTEM FLOW AND
PRESSURE DEMAND.
110 FLUSH-TYPE CHROME BACKFLOW PREVENTER TEST
HEADER WITH FIVE 2-1/2 INCH CHROME HOSE VALVES
WITH CAPS AND LETTERED "TEST CONNECTION".
111 FLUSH-TYPE CHROME BACKFLOW PREVENTER TEST
HEADER WITH TWO 2-1/2 INCH CHROME HOSE VALVES
WITH CAPS AND LETTERED "TEST CONNECTION".
123 SEE CIVIL DRAWINGS FOR LOCATION OF POST INDICATOR
VALVE.
124 CONNECT SPRINKLER SYSTEM RISER TO UNDERGROUND
LEAD-IN LOCATED APPROXIMATELY 5'0" FROM THE EDGE
OF THE BUILDING. REFER TO CIVIL DRAWING FOR
CONTINUATION.
135 SUGGESTED ROUTING FOR ZONE E SINGLE-INTERLOCK
PREACTION SPRINKLER SYSTEM MAIN.
138 SUGGESTED ROUTING FOR ZONE E-WEST WET PIPE
SPRINKLER SYSTEM MAIN.
139 SUGGESTED ROUTING FOR ZONE E-EAST WET PIPE
SPRINKLER SYSTEM MAIN.
SCALE 1/4" = 1'-0"
PARTIAL FIRE SPRINKLER PLAN AREA E - ROOM 125/126
SCALE 1/4" = 1'-0"
PARTIAL FIRE SPRINKLER PLAN AREA E - ROOM 127/129
TO VERIFY ACTUAL
DRY PENDENT LENGTH
SPRINKLER CONTRACTOR
GYPSUM BOARD
OR CEILING TILE.
BRANCH LINE
TEE FITTING.
OBSTRUCTION GREATER
THAN 48" WIDE OR
WITHIN 18" OF
SPRINKLER OVERHEAD
UPRIGHT SPRINKLER
WITH HEAD GUARD
1" DOWN TO
SPRINKLER
BELOW
OBSTRUCTION
1" GLOBE VALVE
1" PLUG
BRANCHLINE
SWIVEL SWAY BRACE
FITTING
PIPE CLAMP
STEEL BEAM/TRUSS
BRACE PIPE
1/2" THRU BOLT
BRACE PIPE
1/2" THRU BOLT
STEEL BEAM/TRUSS
PIPE CLAMP
SWIVEL SWAY
BRACE FITTING
C-CLAMP WITH LOCKNUT
PIPE RING
ALL THREAD ROD
RETAINER STRAP
FINISHED FLOOR
PROVIDE SPLASHBLOCK
AS NECESSARY
1" GLOBE
VALVE OR
TEST DRAIN
ASSEMBLY
1" PIPE FROM
END OF REMOTE
BRANCH LINE
45° ELBOW WITH
CORROSION RESISTANT
OUTLET EQUAL TO ONE
SPRINKLER
SURGE
RESTRAINER
SURGE
RESTRAINER
SURGE RESTRAINER
ALL THREAD ROD
NOTE: TO BE USED ONLY WITH BAND HANGERS TO
RESTRAIN THE UPWARD MOVEMENT OF PIPE AS IT
OCCURS DURING SPRINKLER HEAD ACTIVATION OR
SEISMIC ACTIVITY. INSTALL AT ENDS OF LINES AND AT 30'
INTERVALS ON BRANCH LINES.
2"X1" REDUCING COUPLING
FINISHED FLOOR
2"X1'-0" PIPE NIPPLE
1" GLOBE VALVE
2"X1" REDUCING COUPLING
1" GLOBE VALVE
1" PIPE FROM END OF MOST
REMOTE BRANCH LINE.
PITCH
45° ELBOW WITH CORROSION
RESISTANT OUTLET EQUAL TO
ONE SPRINKLER
EXTERIOR COLUMN.
SPLASHBLOCK, AS NECESSARY.
SPRINKLER CONTRACTOR
TO VERIFY ACTUAL
DRY PENDENT LENGTH
GYPSUM BOARD
OR CEILING TILE
BRANCH LINE
TEE FITTING
SUSPENDED CEILING
WET PIPE SPRINKLER
SYSTEM BRANCH LINE
RECESSED PENDENT SPRINKLER
PIPE RING
ALL THREAD ROD.
C-CLAMP WITH
LOCKNUT
ANGLE IRON
PER NFPA 13
STRUCTURAL
MEMBER
STRUCTURAL SPAN
LOCK
NUTS SPRINKLER
DEFLECTOR
SPRINKLER FRAME
THERMAL LINK OR BULB
(HEAT DETECTOR)
BRANCH LINE OUTLET
BRANCH LINE
1. SPRINKLER FRAME SHALL BE PARALLEL TO SYSTEM BRANCH LINE.
2. SPRINKLER DEFLECTOR SHALL BE PARALLEL TO CEILING, ROOF
OR THE INCLINE OF STAIRS
3. SPRINKLER DEFLECTOR POSITION SHALL BE 1" TO 12" BELOW THE
CEILING IN UNOBSTRUCTED CONSTRUCTION.
4. SPRINKLER DEFLECTOR POSITION SHALL BE 1" TO 6" BELOW THE
STRUCTURAL MEMBER AND A MAXIMUM OF 22" BELOW THE CEILING
OR ROOF DECK WITH OBSTRUCTED CONSTRUCTION.
5. REFER TO NFPA 13 FOR ADDITIONAL OBSTRUCTED CONSTRUCTION
CONSIDERATIONS.
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:1 :0
P
M
D B
A R
B E
R
B B
O O
N E
F-501
R P
A R
K
F
IR
E S
P R
IN
K
L E
R D
E T
A
IL
S
N Z
A S
F
-5
SCALE: NTSF-501
D3 SPRINKLERS BELOW OBSTRUCTIONS
SCALE: NTSF-501
D1 LATERAL SWAY BRACE
SCALE: NTSF-501
D2 LONGITUDINAL SWAY BRACE
SCALE: NTSF-501
B1 STEEL BEAM HANGER DETAIL
SCALE: NTSF-501
B2
WET PIPE SYSTEM AUXILIARY
DRAIN/INSPECTOR'S TEST DETAIL
SCALE: NTSF-501
A4 SURGE RESTRAINER
GENERAL NOTES - FIRE SPRINKLER
A REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS
AND GENERAL NOTES.
B REFER TO SHEET F-501 AND F-502 FOR FIRE SPRINKLER
DETAILS.
C REFER TO SHEET F-503 FOR FIRE RISER DETAILS.
D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR COORDINATION WITH LIGHTS, MECHANICAL
DIFFUSERS, AND CEILING GRID.
12" = 1'-0"F-501
A1 PREACTION INSPECTORS TEST DETAIL
12" = 1'-0"F-501
A2 DRY BARREL PENDENT DETAIL
12" = 1'-0"F-501
A3 RETURN BEND DETAIL
12" = 1'-0"F-501
B3 TRAPEZE HANGER DETAIL
12" = 1'-0"F-501
B4 UPRIGHT SPRINKLER DETAIL
4.9
F G H
BREAK AREA
RECYCLING
SM CONF
2" 2" 2" 2"
6" 6"
10' - 2" 1' - 10" 12' - 0" 9' - 5" 9' - 11"
LH OH LH
[11' 6"] [11' 6"]
[9' 1-1/4"]
[9' 1-1/4"]
[9' 1-1/4"]
6.5
E
F G H H.2E.8E.6
4" 4"4" 4" 4" 4" 4" 4" 4" 4"1
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
VEHICLE
BAYS
VEHICLE
BAYS
12' - 0" 11' - 10" 12' - 2" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 11' - 3" 0' - 9"
OH OH
[11' 9.5"]
[11' 3.5"][11' 3.5"][11' 3.5"][11' 3.5"][11' 3.5"][11' 3.5"][11' 3.5"][11' 3.5"][11' 3.5"]
6"
RN
6" RN 6" RN 6" RN 6" RN 6" RN 6" RN 6" RN 6" RN 6" RN
SPRINKLER SYSTEM DESIGN CRITERIA
PATTERN SYSTEM TYPE/
OCCUPANCY
MINIMUM
SPRINKLER
DENSIT/AREA
HOSE
STREAM
ALLOWANCE/
DURATION
SPRINKLER
K-FACTOR
WET-PIPE
SYSTEM:
LIGHT
HAZARD
0.10 GPM/SF
OVER MOST
REMOTE
1,500 SF
250 GPM
FOR 60
MINUTES
5.6
WET-PIPE
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
8.0
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
NFPA 13
FIGURE
16.2.1.3.2
(D) CURVE
E AND
FIGURE
16.2.1.3.4.1.
0.624 GPM/SF
OVER THE
MOST
REMOTE
2,000 SF
500 GPM
FOR 120
MINUTES
11.2 (HIGH
TEMP)
ROOMS/AREAS
PROTECTED
OFFICE,
RESTROOMS,
TRAINING,
SUPERVISOR
ROOMS, BRIEF
ROOMS, BREAK
ROOM
COMM ROOMS,
STORAGE, IT,
MECH/ELEC
ROOMS,
JANITOR'S
CLOSET, SHOPS,
AND TELECOM
ROOMS
CLASS IV NON-
ENCAPSULATE
D STORAGE UP
TO 22 FEET IN
HEIGHT ON
RACKS WITH 8
FOOT AISLES
SINGLE-
INTERLOCK
PREACTION
SYSTEM:
ORDINARY
HAZARD
0.20 GPM/SF
OVER MOST
REMOTE
2,500 SF
250 GPM
FOR 60
MINUTES
VEHICLE
MAINTENANCE
BAYS
8.0
OH
OH
ST
LH
SPRINKLER LEGEND
TYPE SYMBOL SIZE TEMP K-FACTOR FINISH
QUICK RESPONSE
PENDENT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
UPRIGHT
QUICK RESPONSE
PENDENT
1/2"
3/4"
1/2"
1/2"
8.0
11.2
5.6
8.0
BRASS
BRASS
BRASS
BRASS
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:1 :0
P
M
D B
A R
B E
R
B B
O O
N E
F-502
R P
A R
K
F
IR
E S
P R
IN
K
L E
R D
E T
A
IL
S
N Z
A S
F
-5
SCALE 1/8" = 1'-0"
PARTIAL FIRE SPRINKLER PLAN AREA C
SCALE 1/8" = 1'-0"
PARTIAL FIRE SPRINKLER PLAN - AREA BELOW MEZZANINE
GENERAL NOTES - FIRE SPRINKLER
A REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS
AND GENERAL NOTES.
B REFER TO SHEET F-501 AND F-502 FOR FIRE SPRINKLER
DETAILS.
C REFER TO SHEET F-503 FOR FIRE RISER DETAILS.
D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR COORDINATION WITH LIGHTS, MECHANICAL
DIFFUSERS, AND CEILING GRID.
KEYNOTES
225 SPRINKLERS FED FROM 12 INCH CROSS MAIN IN AREA C
SINGLE INTERLOCK PREACTION SYSTEM. REFER TO
SHEET FP113 FOR CONNECTION.
226 SPRINKLER FED FROM 6 INCH CROSS MAIN IN AREA A
WET PIPE SYSTEM. REFER TO SHEET FP111 FOR
CONNECTION.
FE.8E.6
A1
F-503
FIRE RISER
A2
F-503
6"
6"
6"
6"
" 6
6"6"
E.8E.6
4"
6"
2 1/2"
A1
F-503
212212212
8"
8"
1'-0"
1'-0"
6"
4"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:1 :2
P
M
D B
A R
B E
R
B B
O O
N E
F-503
R P
A R
K
F
IR
E R
IS
E
R R
O O
M D
E T
A
IL
S
N Z
A S
F
-5
GENERAL NOTES - FIRE SPRINKLER
A REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS
AND GENERAL NOTES.
B REFER TO SHEET F-501 AND F-502 FOR FIRE SPRINKLER
DETAILS.
C REFER TO SHEET F-503 FOR FIRE RISER DETAILS.
D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR COORDINATION WITH LIGHTS, MECHANICAL
DIFFUSERS, AND CEILING GRID.
KEYNOTES
201 WALL-MOUNTED FIRE DEPARTMENT CONNECTION WITH
TWO 2-1/2-INCH INLETS. PROVIDE SIGNAGE (APPROVED
BY OWNER) INDICATING REQUIRED SYSTEM FLOW AND
PRESSURE DEMAND.
202 EIGHT-WAY FLUSH-TYPE CHROME BACKFLOW
PREVENTER TEST HEADER WITH EIGHT 2-1/2 INCH
CHROME HOSE VALVES WITH CAPS AND LETTERED "TEST
CONNECTION".
203 6 INCH RISER CHECK VALVE.
204 6 INCH LINE TO SUPPLY AREA D.
205 8 INCH LINE TO SUPPLY AREA B.
206 8 INCH LINE TO SUPPLY AREA C.
207 6 INCH LINE TO THE WET PIPE SYSTEM.
208 BACKFLOW PREVENTER WITH SUPERVISED CONTROL
VALVES.
209 PIPING TO WALL MOUNTED FIRE DEPARTMENT
CONNECTION.
210 CHECK VALVE (TYPICAL).
212 EXTERNALLY RESETTABLE AUTOMATIC FLOW CONTROL
VALVE WITH TRIM.
213 PROVIDE THRUST BLOCK PER NFPA 13.
215 FIRE DEPARTMENT CHECK VALVE
240 PIPING TO BACKFLOW PREVENTER TEST HEADER.
241 FIRE WATER SUPPLY LINE. REFER TO SHEET FP115 FOR
LOCATION OF FIRE LINE BUILDING ENTRY.
F-503
B1 3D - FIRE RISER ROOM 122
SCALE: NTSF-503
B3 ENLARGED FIRE RISER RM 122
SCALE:NTSF-503
A3 ENLARGED FIRE RISER DETAIL RM 125
SCALE:NTSF-503
A4 ENLARGED FIRE RISER DETAIL RM 127
SCALE: NTSF-503
A1 FIRE RISER RM 122 - PLAN NORTH VIEW
SCALE:NTSF-503
A2 FIRE RISER RM 122 - PLAN EAST VIEW
DETECTOR BASE
SMOKE OR HEAT
EXPOSED CEILING
HEAT DETECTOR
J-BOX ON
3/4" EMT CONDUIT
SMOKE OR
MEMBER
STRUCTURAL
MM
FACP
FAT
BATT
GROUND
FLOOR
TYP.
OF 13
RPS
M
C
2 1
M P P
MNCP
LOC
BATT
M
C
RPS
CO
TYP.
OF 7
PARP
P
TYP. OF 4
TYP.
OF 4
HI/LO
C
TYP.
OF 4
SOV
M
WP
D
IS
P L A
Y T
R O
U B
L E
C O
N D
IT
IO
N
D
IS
P L A
Y S
U P
E R
V
IS
O R
Y C
O N
D
IT
IO
N
A C
T U
A T E
C O
M M
O N
T R
O U
B L E
S
IG
N A
L I N
D
IC
A T O
R A
N D
A U
D
IB
L E
A C
T U
A T E
C O
M M
O N
A L A
R M
S
IG
N A
L I N
D
IC
A T O
R A
N D
A U
D
IB
L E
A C
T U
A T E
S U
P E
R V
IS
O
R Y
I N
D
IC
A T O
R A
N D
A U
D
IB
L E
GROUND FAULT
SYSTEM RESET
SYSTEM SILENCE
OPEN CIRCUIT
NOTIFICATION APPLIANCE CIRCUIT SHORT
FIRE ALARM SYSTEM LOW BATTERY
FIRE ALARM AC POWER FAILURE
TROUBLE FUNCTIONS
PANEL FUNCTIONS
BA E FDC
SMOKE DETECTOR MOUNTED OVER FACP AND MNCP
SPRINKLER WATER FLOW SWITCH
MANUAL FIRE ALARM PULL STATION
SPRINKLER TAMPER SWITCH ACTIVATED
SUPERVISORY DEVICES
ALARM DEVICES
SYSTEM INPUT
D
IS
P L A
Y A
L A
R M
D E
V
IC
E
BA C FED
A C
T U
A T E
F
IR
E A
L A
R M
C L E
A R
S T R
O B
E S
V
O
IC
E M
E S
S A
G E
T H
R O
U G
H O
U T B
U
IL
D
IN
G
T E
M P
O R
A R
IL
Y
S
IL
E N
C E
P A
N E
L A
N D
D E
A C
T
IV
A T E
F A
C
IL
IT
Y
A U
D
IB
L E
S A
N D
V
IS
U A
L S
T R
A N
S M
IT
F
IR
E
A L A
R M
S
IG
N A
L T
O B
A S
E R
E P
O R
T
IN
G S
Y S
T E
M
T R
A N
S M
IT
W
A T E
R F
L O
W S
IG
N
A L T
O B
A S
E R
E P
O R
T
IN
G S
Y S
T E
M
C O
N T R
O L P
A N
E L R
E T U
R N
S T
O N
O R
M A
L A
U D
IB
L E
S A
N D
V
IS
U A
L S
S T O
P
T R
A N
S M
IT
T
R O
U B
L E
S
IG
N A
L T
O B
A S
E R
E P
O R
T
IN
G S
Y S
T E
M
T R
A N
S M
IT
S
U P
E R
V
IS
O R
Y S
IG
N
A L T
O B
A S
E R
E P
O R
T
IN
G S
Y S
T E
M
OI JG H L NMK P RQ S
OJIG H LK M N P Q R
NOTIFICATION
SYSTEM OUTPUTS
CONTROL UNIT
ANNUNCIATION FUNCTIONS
CONTROL FACP
FUNC
SIGNAL FROM BUILDING MASS NOTIFICATION SYSTEM PUSH BUTTON / MICROPHONE
S H
U T D
O W
N A
S S
O C
IA
T E
D H
V A
C U
N
IT
DUCT SMOKE DETECTORS (SUPPLY SIDE OF HVAC UNITS)
HVAC UNIT SHUT DOWN SWITCH ACTIVATED
S E
N D
S
IG
N A
L T
O B
M S
S H
U T D
O W
N H
V A
C U
N
IT
S T
H R
O U
G H
O U
T B
U
IL
D
IN
G
NOTES BY SYMBOL " "
CONNECT TO 120 VAC, 20 AMP DEDICATED CIRCUITS. POWERED FROM A SINGLE POWER
PANEL WITH SURGE SUPPRESSION PER UFC 3-520-01.
PROVIDE GROUND PER NFPA 70.
BATTERY CHARGER AND BATTERIES FOR 15 MINUTES OF ALARM AFTER 48 HOURS OF
STANDBY POWER PER UFC 3-600-01.
PROVIDE FIRE ALARM RADIO TRANSCEIVER PANEL FOR TRANSMITTING FIRE ALARM,
TROUBLE, SUPERVISORY, AND WATERFLOW SIGNALS TO THE BASE REPORTING SYSTEM.
FIRE ALARM CONTROL PANEL. REFER TO SPECIFICATION SECTION 283176 FOR SPECIFIC
OPERATIONAL SEQUENCE/ PRIORITY OF FA AND RECORDED MESSAGES.
SMOKE DETECTOR FOR PROTECTION OF FACP / MNCP / REMOTE POWER SUPPLY PANELS.
PROVIDE ADDITIONAL AUDIBLE/VISUAL NOTIFICATION APPLIANCES AND ASSOCIATED
POWER SUPPLIES AND/OR TRANSPONDERS AS NECESSARY TO MEET THE AUDIBILITY,
INTELLIGIBILITY, AND VISIBILITY REQUIREMENTS PER NFPA 72. PROVIDE TRANSIENT
VOLTAGE SURGE SUPRESSION (TVSS) ON ALL FIRE ALARM AND MASS NOTIFICATION
CIRCUITS PER NFPA 70, NFPA 72, UFC 3-600-01, AND MANUFACTURER'S REQUIREMENTS.
PROVIDE EXTERIOR OMNI DIRECTIONAL ANTENNA FOR TRANSMITTING SIGNALS TO THE
BASE REPORTING SYSTEM. FIELD LOCATE TRANSMITTER ANTENNA TO OPTIMIZE SIGNAL TO
BASE FIRE DEPARTMENT.
MONITOR ALL WET PIPE AND SINGLE-INTERLOCK PREACTION SPRINKLER SYSTEM
TAMPER SWITCHES, WATER FLOW SWITCHES, HI/LO NITROGEN PRESSURE SWITCHES,
TAMPER SWITCHES ON THE BACKFLOW PREVENTER ASSEMBLY, AND POST INDICATOR
VALVE.
PROVIDE LOCAL OPERATING CONSOLE PANEL WITH MICROPHONE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ROUTE CLASS A CIRCUITS BACK TO PANEL.11.
A C
T U
A T E
M A
S S
N O
T
IF
IC
A
T
IO
N A
M B
E R
S T R
O B
E S
V
O
IC
E M
E S
S A
G E
T H
R O
U G
H O
U T B
U
IL
D
IN
G
HI/LO PRESSURE NITROGEN SUPERVISORY SWITCH ACTIVATED
S H
U T D
O W
N A
L L A
IR
-H
A N
D L
IN
G E
Q U
IP
M
E N
T A
N D
H V
L S
F A
N S
MASS NOTIFICATION CONTROL PANEL WITH AUTONOMOUS CONTROL UNIT AND MICROPHONE.
REFER TO SPECIFICATION SECTION 283176 FOR SPECIFIC OPERATIONAL SEQUENCE/ PRIORITY
OF MNS/LIVE VOICE SYSTEMS AND RECORDED MESSAGES.
12.
PROVIDE CARBON MONOXIDE DETECTOR WHERE FUEL BURNING EQUIPMENT IS LOCATED.
DETECTOR WILL INITIATE A UNIQUE VOICE VOICE NOTIFICATION MESSAGE UPON
ACTIVATION, PER UFC 3-600-01 AND UFC 4-021-01.
13.
CARBON MONOXIDE DETECTOR
A C
T U
A T E
C A
R B
O N
M O
N O
X
ID
E V
O
IC
E N
O T
IF
IC
A
T
IO
N M
E S
S A
G E
T H
R O
U G
H O
U T B
U
IL
D
IN
G
T R
A N
S M
IT
C
A R
B O
N M
O N
O X
ID
E
D E
T E
C T O
R S
IG
N
A L T
O B
A S
E R
E P
O R
T
IN
G S
Y S
T E
M
PROVIDE SPOT TYPE HEAT DETECTORS THAT ARE LISTED FOR RELEASE OF PREACTION
FIRE SPRINKLER SYSTEMS SO THAT THEY COVER THE ENTIRE ARE COVERED BY EACH
SINGLE-INTERLOCK PREACTION SYSTEM. INSTALL PER NFPA 72 AND MANUFACTURERS
INSTRUCTIONS TO FUNCTION WITH THE SINGLE-INTERLOCK PREACTION SPRINKLER
SYSTEMS.
14.
PROVIDE A PREACTION RELEASING PANEL (PARP) CONFIGURED FOR SINGLE-
INTERLOCK PREACTION OPERATION FOR EACH SINGLE-INTERLOCK PREACTION SYSTEM
PROVIDED.
15.
PROVIDE A MEANS TO ACTUATE THE PREACTION VALVE INDEPENDENT OF THE DETECTION
DEVICES AND OF THE SPRINKLERS, PER NFPA 13.
16.
PROVIDE AN ELECTRIC SOLENOID VALVE ON EACH SINGLE-INTERLOCK PREACTION RISER
DELUGE VALVE. UPON OPERATION OF THE ASSOCIATED DETECTION SYSTEM THE
SOLENOID VALVE WILL BE ENERGIZED OPEN, CAUSING THE DELUGE VALVE TO OPEN AND
FILL THE SYSTEM WITH WATER.
17.
HEAT DETECTOR IN SINGLE-INTERLOCK PREACTION SPRINKLER ZONES
SINGLE-INTERLOCK PREACTION SYSTEM EMERGENCY RELEASE STATION
E N
E R
G
IZ
E S
O L E
N O
ID
V
A L V
E O
P E
N O
N A
S S
O C
IA
T E
D S
IN
G
L E
-I N
T E
R L O
C K
P R
E A
C T
IO
N S
Y S
T E
M
S T
DEVICE REMOVAL
T
PROVIDE A SEPARATE NAC CIRCUIT FOR WATERFLOW BELL.18.
T E
M P
O R
A R
IL
Y
S
IL
E N
C E
F
IR
E A
L A
R M
A U
D
IB
L E
S A
N D
V
IS
U A
L S
U
U
PROVIDE AN ELECTRIC WATERFLOW BELL ON THE EXTERIOR WALL AT THE LOCATION
SHOWN ON THE FIRE ALARM PLANS.
19.
DROP CEILING TILE
DETECTOR BASE
SMOKE OR HEAT
4"x4"x2-1/4" J-BOX
J-BOX ON FLOOR SLAB
SMOKE OR HEAT DETECTOR
3/4" FLEX WITH FIRE
DETECTION CIRCUITS
"T" BAR TYPE HANGER
3/4" EMT CONDUIT
MANUFACTURERS
RECOMMENDATIONS IN
COAXIAL CABLE AS PER
ALARM TRANSMITTER.
3/4" CONDUIT TO FIRE
SHALL BE APPROVED BY CONTRACTING
GROUND WIRE USE NO. 10
GROUND CLAMP
AWG COPPER WIRE OR
WIRE. SUPPORT THE WIRE
STANDOFF SUPPORT
LARGER FOR GROUNDING
EVERY 4'-0" TO 6'-0".
GROUND ROD 3/4" X 8':
LOCATE GROUND ROD AWAY FROM
TRAFFIC AREA. EXACT LOCATION
OFFICER PRIOR TO INSTALLATION
CONTRACTOR TO PROVIDE
SILICONE CAULKING AT THE
CONDUIT PENETRATION
COAXIAL CABLE
LOOP
SERVICE
PROOF
MOUNTED
COAXIAL CABLE
GROUND CLAMP
OMNI DIRECTIONAL
MAST SIZE
AS REQUIRED
ANTENNA
WALL
RAIN PROOF
ENCLOSURE
BUILDING WALL
WEATHER-
HEAD
DRIP
ROOF/PARAPET
LIGHTNING ARRESTER
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:1 :2
P
M
D B
A R
B E
R
B B
O O
N E
F-504
R P
A R
K
F
IR
E A
L A
R M
M
A S
S N
O T
IF
IC
A T
I O N
D E
T A
IL
S
N Z
A S
F
-5
SCALE: NTSF-504
D2 EXPOSED CEILING DETECTOR DETAIL
SCALE SCALE: NTSF-504
A4 FIRE ALARM / MASS NOTIFICATION RISER DETAIL
SCALE SCALE: NTSF-504
A1 FIRE ALARM/ MASS NOTIFICATION SEQUENCE OF OPERATIONS
SCALE: NTSF-504
D4 SUSPENDED CEILING DETECTOR DETAIL
NTSF-504
B4 FIRE ALARM ANTENNA DETAIL
S
DRAWING ABBREVIATIONS LEGEND
PIPING SYMBOLS
A______________________________________________________
ABV ABOVE
ADJ ADJUSTABLE
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
ANSI AMERICAN NATIONAL STANDARD INSTITUTE
ARCH ARCHITECT, ARCHITECTURAL
ARI AIR CONDITIONING & REFRIG. INSTITUTE
ASHRAE AMERICAN SOCIETY OF HEATING, REFRIG.
AND AIR CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS
B______________________________________________________
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BLDG BUILDING
BOP BOTTOM OF PIPE
BOS BOTTOM OF STRUCTURE
C______________________________________________________
CFH CUBIC FEET PER HOUR
CIRC CIRCULATING
CLG CEILING
CO CLEANOUT
CP CIRC. PUMP
D______________________________________________________
DCBFP DOUBLE CHECK BACKFLOW PREVENTER
DCO DOUBLE CLEANOUT
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
D.I. DUCTILE IRON
DN DOWN
DWG DRAWING
E______________________________________________________
EEWS EMERGENCY EYEWASH SHOWER
ELEC ELECTRICAL
ET EXPANSION TANK
EWC ELECTRIC WATER COOLER
F______________________________________________________
FA FROM ABOVE
FB FROM BELOW
FCO FLOOR CLEANOUT
FLA FULL LOAD AMPS
FS FLOW SWITCH
G______________________________________________________
GPM GALLONS PER MINUTE
H______________________________________________________
HB HOSE BIBB
HTG HEATING
I______________________________________________________
IE INVERT ELEVATION
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
IN WC INCHES OF WATER COLUMN
IN WG INCHES OF WATER GAUGE
IW INDUSTRIAL WASTE
J______________________________________________________
J-BOX JUNCTION BOX
JT JOINT
K______________________________________________________
K CONDUCTIVITY (BT/SF/1" THICKNESS)
KW KILOWATT
KWH KILOWATT-HOUR
L______________________________________________________
L LAVATORY
M______________________________________________________
MECH MECHANICAL
MFGR MANUFACTURER
MS MOP SINK
N______________________________________________________
NC NOISE CRITERIA, NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MFGR'S ASSOC.
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NFWH NONFREEZE WALL HYDRANT
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
O______________________________________________________
OA OUTDOOR AIR
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMIN.
OWS OIL / WATER SEPARATOR
P______________________________________________________
PBP PRIMARY BOOSTER PUMP
PD PRESSURE DROP
PLBG PLUMBING
PROVIDE FINISH AND INSTALL
Q______________________________________________________
QTY QUANTITY
R______________________________________________________
RA RETURN AIR
RE: REFERENCE, REFER
REQD REQUIRED
REV REVISION, REVISE
RTN RETURN
S______________________________________________________
S SINK
SD STORM DRAIN
SA SUPPLY AIR
SH SHOWER
SPEC SPECIFICATION
SS SANITARY SEWER
NEW EQUIPMENT
EQUIPMENT CLEARANCE
EQUIPMENT SYMBOLS
PITCH DOWN IN DIRECTION OF ARROW
DIRECTION OF FLOW
BRANCH - TOP CONNECTION
BRANCH - SIDE CONNECTION
CONCENTRIC REDUCER
RISER UP (ELBOW)
CAPPED PIPE
BRANCH - BOTTOM CONNECTION
RISE OR DROP IN PIPE
RISER DOWN (ELBOW)
PUMP
LINE/WALL CLEANOUT
WATER METERM
G
A
GAS METER
AIR OUTLET VALVE
MISCELLANEOUS
DCBFP
RPZ
P
FLOOR CLEANOUT
HOSE BIBB/WALL HYDRANT
FLOOR DRAIN
P-TRAP
PLUMBING FIXTURES AND EQUIPMENT
DOUBLE CHECK BACKFLOW PREVENTER
REDUCED PRESSURE BACKFLOW
PREVENTER
RISER DESIGNATION "P": DENOTES
SANITARY WASTE AND VENT RISER
DIAGRAM OR DOMESTIC COLD AND
HOT WATER RISER DIAGRAM
PROCESS VACUUM CONNECTION
BREATHING AIR CONNECTION
PROCESS COMPRESSED AIR CONNECTION
DEBRIS VACUUM CONNECTION
KEYNOTE REFERENCE
POINT OF CONNECTION
NEW TO EXISTING
WATER HAMMER ARRESTOR
VALVE SYMBOLS
CHECK VALVE (NON SLAM)
GLOBE VALVE
GATE VALVE
PRESSURE REDUCING VALVE (PRV)
BALL VALVE
BUTTERFLY VALVE
AUTOMATIC BALANCING VALVE
TEMPERATURE WELL
FLANGED VALVE
(GATE VALVE
SHOWN)
ORIFICE FLOW PLATE FS
PS
PIPE ANCHOR
PIPE ANCHOR
ECCENTRIC REDUCER
BLIND FLANGE
PRESSURE GAGE WITH COCK
UNION (SCREWED)
ORIFICE UNION
FLANGED CONNECTION
STRAINER WITH BLOWDOWN VALVE
TEMPERATURE & PRESSURE PORT
THERMOMETER
FLOW SWITCH
FLEX CONNECTION
BELLOWS CONNECTION
FLEX PIPE
PRESSURE SWITCH
(DOUBLE SPHERE NEOPRENE TYPE)
SITE/UTILITY INFORMATION
S (CONTINUED)______________________________________
ST STORAGE TANK
STD STANDARD
T__________________________________________________
TD TRENCH DRAIN
TMV THERMOSTATIC MIXING VALVE
TYP TYPICAL
U__________________________________________________
U URINAL
UF UNDERFLOOR
UL UNDERWRITERS LABORATORIES, INC.
V___________________________________________________
V VENT
VERT VERTICAL
VTR VENT THROUGH ROOF
W___________________________________________________
WB WALL BOX
WC WATER CLOSET
WCO WALL CLEANOUT
WH WATER HEATER
PLUG VALVE
A COMPRESSED AIR
VENTURI FLOW METER
NEEDLE VALVE
VALVE IN DROP
VALVE IN RISE
VALVE IN CENTER DROP
GATE VALVE W/
3/4" HOSE THREAD
ADAPTER
TWO-WAY CONTROL VALVE
THREE-WAY CONTROL VALVE
SOLENOID VALVE
SAFETY VALVE OR
PRESSURE RELIEF
VALVE
MANUAL BALANCING VALVE
OS&Y VALVE
DRAWING/DETAIL REFERENCE KEY
RE : 2 / P-201
REFER TO
DRAWING/DETAIL NUMBER
SHEET NUMBER ON
WHICH DETAIL IS DRAWN
GENERAL NOTES
REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS
FOR CONSTRUCTION.
COORDINATE THE EXACT LOCATION OF FLOOR DRAINS AND
FLOOR SINKS WITH THE ARCHITECTURAL DRAWINGS AND
MECHANICAL EQUIPMENT LOCATIONS PRIOR TO INSTALLATION
OF DRAINS. PROVIDE A RADIUS AROUND THE FLOOR DRAIN
THAT SLOPES TOWARD THE FLOOR DRAIN FROM THE FINISHED
FLOOR ELEVATION TO A TOP OF DRAIN ELEVATION BETWEEN
1/2" AND 3/4" BELOW FINISHED FLOOR, UNLESS OTHERWISE
NOTED ON THE DRAWINGS. THE RADIUS AND RATE OF SLOPE
IS TO BE FIELD COORDINATED.
FURNISH ACCESS DOORS FOR INSTALLATION IN WALLS AND
CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED
PLUMBING EQUIPMENT, VALVES, CONTROLS, AND OTHER
DEVICES.
PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS,
REVISIONS, AMENDMENTS OR SUPPLEMENTS OF APPLICABLE
STATUTES, ORDINANCES, CODES, OR REGULATIONS OF
FEDERAL, STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION IN EFFECT ON THE DATE BIDS ARE RECEIVED.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
WHERE APPROVAL CODES HAVE BEEN ESTABLISHED BY
OSHA, UL (UNDERWRITERS LABORATORIES), AMERICAN
CODES, ANSI, ARI, ASA, ASHRAE, ASPE, ASSE, ASTM, AWWA,
NEC, NFPA, SMACNA, OR THE STATE FIRE INSURANCE
REGULATORY BODY, FOLLOW THESE STANDARDS WHETHER
OR NOT INDICATED ON THE DRAWINGS.
COORDINATE WORK WITH ARCHITECTURAL FEATURES AND
COORDINATE WORK SUCH THAT INTERFERENCES BETWEEN
PIPING, DUCTWORK, EQUIPMENT, FIRE PROTECTION WORK,
PLUMBING WORK, ELECTRICAL WORK, AND BUILDING
STRUCTURE WILL BE AVOIDED.
PROVIDE THE ENTIRE SYSTEM AND ITS COMPONENT ITEMS
OF EQUIPMENT IN OPERATING CONDITION WITHOUT
OBJECTIONABLE VIBRATION OR NOISE. PROVIDE WATER
HAMMER ARRESTORS AT RESTROOM PLUMBING CHASES.
NOISE LEVELS IN OFFICES SHALL BE MAINTAINED AT OR
BELOW NC35.
PROVIDE ALL WIRING AND ELECTRICAL CONTROLS IN
ACCORDANCE WITH NFPA 70 (NEC).
VERIFY AND DOCUMENT EXISTING CONDITIONS AND
DIMENSIONS ON THE JOB SITE PRIOR TO STARTING ANY
WORK.
DO NOT SCALE THESE DRAWINGS FOR CONSTRUCTION
PURPOSES.
INSTALL PIPING TO PROVIDE THE MAXIMUM POSSIBLE CLEAR
HEIGHT UNDERNEATH. MAINTAIN A MINIMUM OF 6 INCHES
ABOVE FINISHED CEILING TO PROVIDE CLEARANCE FOR
LIGHTING FIXTURES.
CONTRACTOR TO MAKE ALL FINAL CONNECTIONS TO
EQUIPMENT, INCLUDING OWNER FURNISHED.
VENT TERMINALS SHALL EXTEND A MINIMUM OF 12" ABOVE
THE FINISHED ROOF AND SHALL BE LOCATED A MINIMUM OF
10 FEET HORIZONTALLY FROM ANY DOOR, OPERABLE
WINDOW, OR OTHER AIR INTAKE OF THE BUILDING OR
ADJACENT BUILDING UNLESS THE VENT TERMINAL IS AT
LEAST 2 FEET ABOVE THE TOP OF SUCH OPENING.
ALL VENT LINES ARE TO RISE VERTICALLY (45 DEG. ANGLE OR
GREATER FROM HORIZONTAL) TO MINIMUM OF 6" ABOVE THE
HIGHEST FLOOD LEVEL RIM OF THE HIGHEST FIXTURE
SERVED BY VENT.
TO PROVIDE FROST CLOSURE, ALL VENT EXTENSIONS
THROUGH ROOF OR WALL SHALL BE A MINIMUM OF 3 INCHES
IN DIAMETER. ANY INCREASE IN THE SIZE OF THE VENT
SHALL BE MADE INSIDE THE STRUCTURE A MINIMUM OF 1
FOOT BELOW THE ROOF OR INSIDE THE WALL.
NO PVC PIPE SHALL BE PERMITTED ABOVE THE CEILING AS
THE CEILING SPACE IS A RETURN AIR PLENUM.
GENERAL NOTES
(CONTINUATION)
NATURAL GAS DATA
NATURAL GAS IS SUPPLIED TO THE SITE. GAS PIPE SIZES ARE
BASED ON A PRESSURE OF 2.0 PSIG AFTER THE METER AND MAIN
REGULATOR AND A 1.0 PSIG DROP. REGULATORS WILL BE
REQUIRED AT EACH NATURAL GAS USER. ESTIMATED LOAD IS
6,947 KBTU/HR. LOW PRESSURE GAS IS RATE FOR 925 BTU/ACF
DUE TO ALTITUDE.
WATER SERVICE FLOW TEST DATA
WATER PIPE SIZES ARE BASED ON A STATIC PRESSURE OF 46 PSI
AND MINIMUM RESIDUAL PRESSURE OF 45 PSIG AT A FLOW RATE
OF 1,021 GPM AT THE LOCATION WHERE THE MAIN SERVICE
ENTERS THE BUILDING. DESIGN PRESSURE IS EXPECTED TO BE
BETWEEN 43.9 AND 49.9 PSIG AT THE BUILDING ENTRANCE.
ESTIMATED PEAK LOAD IS 101 GPM.
SANITARY DRAINAGE
THE ESTIMATED CONNECTED SANITARY DRAINAGE LOAD IS 60
DFU'S OR APPROXIMATELY 54 GPM.
STORM WATER
THE BASIS OF DESIGN IS A STORM INTENSITY OF 1.8 INCHES PER
HOUR.
CODE COMPLIANCE
THE PLUMBING SYSTEMS ARE IN COMPLIANCE WITH THE 2015
INTERNATIONAL PLUMBING CODE AS MODIFIED BY UFC 3-420-01.
DOMESTIC HOT WATER
NORMAL DOMESTIC HOT WATER DESIGN BASED ON 40°F COLD
WATER, ONE EMERGENCY SHOWER AND EYE WASH OPERATING
WITH 80 TO 85° F DISCHARGE WATER TEMPERATURE.
PIPING TYPES
SANITARY SEWER
SANITARY VENT (V)
DOMESTIC COLD WATER (CW)
DOMESTIC HOT WATER (110°F) (HW)
DOMESTIC HOT WATER RETURN (HWR)
NATURAL GAS
CONDENSATE DRAIN
NON POTABLE WATER
TRAP PRIMER
SS
V
TP
NG
CD
NPW
STORM DRAINSD
CA
OD
COMPRESSED AIR
OVERFLOW DRAIN
VAC VACUUM
INDUSTRIAL WASTEIW
CW
HW
HWR
SUBSOIL DRAINAGESSD
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
McHENRY WALLACE JR
52349
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:5 :0
P
M
M W
A L L
A C
E
Y M
A S
H N
I
P-001
P B
A K
E R
A B
B R
E V
IA
T
IO
N
S S
Y M
B O
L S
A
N D
G E
N E
R A
L N
O T
E S
N Z
A S
P
-0
M NA B C D E F G H J K L
3.2
E.6 E.8 H.2
7.1
6.5
5.5
4.9
4.2
REFER TO:
UNDERSLAB P104
ABOVE SLAB P114
REFER TO:
UNDERSLAB P101
ABOVE SLAB P111
REFER TO:
UNDERSLAB P103
ABOVE SLAB P113
REFER TO:
UNDERSLAB P105
ABOVE SLAB P115
REFER TO:
UNDERSLAB P102
ABOVE SLAB P112
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
McHENRY WALLACE JR
52349
8 16 3241216
SCALE: 1/16"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
A
B C
OVERALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
D
E s /2
-1
-0
/1
/2
:5 :0
P
M
M W
A L L
A C
E
Y M
A S
H N
I
P-100
P B
A K
E R
O V
E R
A L L P
L U
M B
I N G
P L A
N
N Z
A S
P
-1
SCALE 1/16" = 1'-0"
A1
OVERALL PLUMBING PLAN
GENERAL NOTES
1 REFER TO P-401 FOR ENLARGED PLANS, P-501 THRU
P-503 FOR DETAILS, P-601 AND P-602 FOR SCHEDULES,
AND P-800 THRU P-802 FOR SCHEMATICS.
E F G H J
3.2
E.6 E.8 H.2
4.9
4.2
S
S 4" SS
3" SS
FS-1FS-1
FS-1
FD-1
FD-1
MMT OIC OFFICE
MMT
SCHEDULERS
EMT
SCHEDULERS
EMT OIC OFFICE
FORCE
GENERATION
VES OIC OFFICE
VES VEHICLE
OFFICE
VES TRAINING
ROOM
CONFERENCE
CONFERENCE
CER
ELECTRICAL
FIRE RISER
MECHANICAL
YARD
MENS LOCKER
ROOM
WOMENS
MEN
FD-2
2" SS DN
2" V UP
4" SS DN
2" V UP
2" V UP
4" SS DN
S S
2" V UP
4" CW
SERVICE
ENTRANCESEE CIVIL FOR
CONTINUATION
IE: 6'-0" BFF
SEE CIVIL FOR
CONTINUATION
IE: 7'-0" BFF
SEE CIVIL FOR
CONTINUATION
IE: 6'-10" BFF
FS-1
FD-1
3" SS
FCO
DCO
FCO
RE: C2 /P-501
4" CW UP
4" SS
2" P-TRAP UP TO MS-1
2" V UP
N G006
007TYP.
6" SD FA
6" SD FA
6" SD FA
6" SD FA
6" SD FA
6" SD FA
6" SD FA
TO WCO
4" SS UP
2" SS FA
6" SD FA
6" SSD
6" SSD
S S
D
S S
D
6" SSD
6" SSD
S S
D
FD-1
S S
3" SS
FCO
S S
3" SS DN
FROM WB-1
6" SSD
FD-2
FD-2 3" SS
FS-1
FD-2
4" SS
S S
6" SD
SH-2
SH-1
SH-1 SH-2
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
McHENRY WALLACE JR
52349
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
A
AREA A
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:5 :0
P
M
M W
A L L
A C
E
Y M
A S
H N
I
P-101
P B
A K
E R
U N
D E
R F
L O
O R
P L U
M B
IN
G
P L A
N
A R
E A
A N
Z A
S
P
-1
SCALE 1/8" = 1'-0"
A1
UNDERFLOOR PLUMBING PLAN - AREA A
GENERAL NOTES - UNDERFLOOR PLAN
A BUILDING FINISHED FLOOR ELEVATION AT THE OFFICE
AREA IS 3472' PER CIVIL DRAWINGS.
B NO UNDERFLOOR PIPING IN VEHICLE BAY UNLESS
OTHERWISE NOTED.
C SLOPE TRENCH DRAIN PIPING IN THE DIRECTION OF THE
SLOPE ARROWS BY 0.6%.
D REFER TO P-602 FOR FLOOR DRAIN AND FLOOR SINK
SCHEDULE.
E PIPING CONNECTED TO THE VEHICLE TRENCH DRAINAGE
SYSTEM SHALL BE CAST IRON PIPING FROM THE TRENCH
DRAIN TO THE POINT OF CONNECTION OF SITE PIPING.
F FLOOR SINKS AND FLOOR DRAINS SHALL HAVE ASSE 1072
BARRIER TYPE TRAP GUARDS.
G TRENCH DRAINS SHALL HAVE DEEP SEAL CAST IRON
TRAPS.
H PROVIDE A MINIMUM OF 1'-0" CLEARANCE BETWEEN
BOTTOM OF GRADE BEAM AND TOP OF PIPE WHEREVER
PIPES PASS UNDER THE FOUNDATION.
I DUE TO LOCAL AREA FROST DEPTH, ALL UNDERGROUND
PIPING THAT CROSSES THE FOUNDATION IS AT LEAST 12"
BELOW BEAMS. NO BEAM PENETRATIONS ARE REQUIRED.
J SSD AND SD PIPING ARE SEPARATE SYSTEMS. ALL SSD
PIPING RUNS AT A DEEPER INVERT THAN SD PIPING.
REFER TO CIVIL.
KEYNOTES
006 3" NG UP TO METER. RE: A1/P-801 FOR DETAIL.
007 6" SD I.E. 3.0' B.F.F. RE: CIVIL FOR CONTINUATION. RE:
C1/P-502 FOR BOOT DETAIL.
008 6" SSD I.E. 5.1' B.F.F. RE: CIVIL FOR CONTINUATION. RE:
C1/S-501 FOR DETAIL.
A B C D
7.1
6.5
5.5
4.9
4" IW
4" IW
4" IW
IE = 4'-2" BFF
IE = 3'-4" BFF
VEHICLE BAYS
SEE CIVIL FOR
CONTINUATION
IE: 7'-4" BFF
IW
IW
M A
T C
H L
IN
E
R E
F E
R A
P
-1
DCO
RE: C2/P-501
6" SD FA
TYP.
6" SD FA
6" SD FA
6" SD FA
TYP.
6" SSD
S S
D
6" SSD
S S
D
TD-1 TD-1 TD-1 TD-1
012 012
013013 013013
TRANSITION DOWN
45 DEGREES
I.E. = -6' 4" BFF
OWS-1
RE: A4/P-503 AND
SPECIFICATIONS FOR
ADDITIONAL INFORMATION
4" IW
TD-1 TD-1
TD-1
TD-1
013013
45° OFFSET INTO MAINIE = 3'-4" BFF
013013
4" V
FCO
FCO 021021
FCO
IE = 2'-1" BFF
IE = 2'-1" BFF
IE = 2'-1" BFF
IE = 2'-2" BFF
IE = 2'-2" BFFIE = 2'-1" BFF
4" IW
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
McHENRY WALLACE JR
52349
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
B
AREA B
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R s /2
-1
-0
/1
/2
:5 :0
P
M
M W
A L L
A C
E
Y M
A S
H N
I
P-102
P B
A K
E R
U N
D E
R F
L O
O R
P L U
M B
IN
G
P L A
N
A R
E A
B N
Z A
S
P
-1
SCALE 1/8" = 1'-0"
A1
UNDERFLOOR PLUMBING PLAN - AREA B
GENERAL NOTES - UNDERFLOOR PLAN
A BUILDING FINISHED FLOOR ELEVATION AT THE OFFICE
AREA IS 3472' PER CIVIL DRAWINGS.
B NO UNDERFLOOR PIPING IN VEHICLE BAY UNLESS
OTHERWISE NOTED.
C SLOPE TRENCH DRAIN PIPING IN THE DIRECTION OF THE
SLOPE ARROWS BY 0.6%.
D REFER TO P-602 FOR FLOOR DRAIN AND FLOOR SINK
SCHEDULE.
E PIPING CONNECTED TO THE VEHICLE TRENCH DRAINAGE
SYSTEM SHALL BE CAST IRON PIPING FROM THE TRENCH
DRAIN TO THE POINT OF CONNECTION OF SITE PIPING.
F FLOOR SINKS AND FLOOR DRAINS SHALL HAVE ASSE 1072
BARRIER TYPE TRAP GUARDS.
G TRENCH DRAINS SHALL HAVE DEEP SEAL CAST IRON
TRAPS.
H PROVIDE A MINIMUM OF 1'-0" CLEARANCE BETWEEN
BOTTOM OF GRADE BEAM AND TOP OF PIPE WHEREVER
PIPES PASS UNDER THE FOUNDATION.
I DUE TO LOCAL AREA FROST DEPTH, ALL UNDERGROUND
PIPING THAT CROSSES THE FOUNDATION IS AT LEAST 12"
BELOW BEAMS. NO BEAM PENETRATIONS ARE REQUIRED.
J SSD AND SD PIPING ARE SEPARATE SYSTEMS. ALL SSD
PIPING RUNS AT A DEEPER INVERT THAN SD PIPING.
REFER TO CIVIL.
KEYNOTES
007 6" SD I.E. 3.0' B.F.F. RE: CIVIL FOR CONTINUATION. RE:
C1/P-502 FOR BOOT DETAIL.
008 6" SSD I.E. 5.1' B.F.F. RE: CIVIL FOR CONTINUATION. RE:
C1/S-501 FOR DETAIL.
012 PROVIDE 3" IW FROM SIDE OUTLET OF TD-1. PROVIDE SAN
TEE DOWN TO 3" IW P-TRAP AND 3" IW UP TO CLEANOUT.
013 PROVIDE 45 DEGREE FITTING DOWN INTO ROLLED 90
DEGREE FITTING AT THIS LOCATION.
015 PROVIDE 4" IW FROM SIDE OUTLET OF TD-1. PROVIDE SAN
TEE DOWN TO 4" IW P-TRAP AND OFFSET 4" IW UP TO
CLEANOUT.
016 4" VENT. ROUTE AT 45 DEGREE ANGLE BELOW GRADE TO
EDGE OF GRADE BEAM. ABOVE GRADE ROUTE TO COLUMN
AND VENT THROUGH ROOF.
019 OFFSET 3" IW TO WALL. PROVIDE WALL CLEANOUT 3' ABOVE
GRADE AND ROUTE 2" V UP FROM WCO.
021 PROVIDE FORKLIFT RATED CLEANOUT.
E.6 E.8 H.2
6.5
5.5
4.9
IE = 3'-4" BFF
4" P-TRAP UP TO FS-1
4" IW P-TRAP
UP TO FS-1
4" IW P-TRAP
UP TO FS-1
2" IW UP TO S-2
VES STORAGE
VES STORAGE
4" IW
4" IW
SM CONF
RECYCLING
BREAK AREA
VES STORAGE
4" IW
4" IW P-TRAP
UP TO FS-1
4" IW P-TRAP
UP TO FS-1
2" IW UP TO S-2
IW
MATCHLINE
REFER A1 P-101
M A
T C
H L
IN
E
R E
F E
R A
P
-1
M A
T C
H L
IN
E
R E
F E
R A
P
-1
MATCHLINE
REFER A1 P-105
FCO
S-2 S-2
S-2 S-2
EEWS-1 EEWS-1EEWS-1 EEWS-1
FS-1
FCO
FCO
021FCO
FCO
FS-1 FS-1 FS-1
FS-1
IW
FD-2 3" SS
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
LANOIS
P
F
SE
O R
S
FOETAT
NE
R E
NI
G
E
S
TE
AX
L I C E N S E D
McHENRY WALLACE JR
52349
164 8268
SCALE: 1/8"=1'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ®
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
PLAN
NORTH
KEY PLAN
Ja co bs E ng in ee rin g G ro up
In c.
T ex as R eg is te re d E ng in ee rin g F irm F
-2
M ai n
S tre et F or t W or th
, T X
JE
P ro j.
N o.
F
D Z
D
A
N S
I D
A S
S H
O W
N
R
B
E S
A N
C O
N
W
D
W
R
P R
O
JE
C T
N U
M B
E R
: N
ZA
S
M A
L M
S T
R O
M A
IR
F
O R
C E
B A
S E
M
O N
T A
N A
M
IS
S
IL
E M
A
IN
TE
N
A N
C E
D
IS
P A
TC
H
F A
C
IL
IT
Y
(M M
D F)
S E
A T
T L E
D
IS
T R
IC
T
S E
A T
T L E
W
A S
H
IN
G T
O N
Seattle District
M
A R
C
AREA C
M A
R K
D E
S C
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.