Solicitation Amendment - W912DS26QA0160002.pdf
PDF 3 MB Posted
- Attached to
- FY26 Upgrades for Various Recruiting Stations
- Solicitation number
- W912DS26QA016
About this file
This is a Solicitation Amendment for FY26 facility upgrades at five military recruiting stations across Upstate New York. The U.S. Army Corps of Engineers, New York District, issued this Women-Owned Small Business (WOSB) solicitation under contract number W912DS26QA0160002 with a 90-day completion requirement from contract award and a delivery deadline of November 30, 2026. The work encompasses interior and exterior upgrades at five locations: Army Medical Command (21 Aviation Road, Albany), Army Recruiting (1306-1308 Ulster Avenue, Kingston and 959 Route 9, Queensbury), Navy Recruiting (63 Market Street, Potsdam and 1726 Black River Boulevard, Rome), and Marines Officer Selection Station (2021 Western Avenue, Albany).
The scope of work includes specialized construction and installation services: video intercom entry control systems with Aiphone IXG Series components at two Army recruiting locations; exterior pylon signage with LED technology and photocell timers at the Kingston facility; flooring installations including porcelain tiles (162 SF) at Queensbury and porcelain/vinyl composition tiles at Potsdam; carpet tile installations (55-128 SY) at Potsdam and Rome; interior and exterior door replacements and repairs with specified hardware schedules; interior wall graphics and gypsum wallboard installations at Potsdam; and chair rail installation. All work must be performed during normal business hours (9 AM-5 PM) in the presence of authorized military personnel, with the contractor responsible for site cleanup, furniture relocation, and waste removal. The solicitation specifies firm fixed pricing and incorporates prevailing wage requirements under New York General Decision Number NY20260002, with wage rates varying by county and trade classification. Contractors must obtain prior authorization through Jane Arnold (jane.e.arnold@usace.army.mil, 917-647-0037) before site access and must complete full inspection and obtain approval before payment release within 30 days of completion.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WOMEN-OWNED SMALL
BUSINESS (WOSB)
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES
1. REQUISITION NUMBER PAGE 1 OF
2. CONTRACT NUMBER 3. AWARD/EFFECTIVE
DATE
4. ORDER NUMBER 5. SOLICITATION NUMBER 6. SOLICITATION ISSUE
DATE
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME b. TELEPHONE NUMBER (No collect 8. OFFER DUE DATE/
LOCAL TIME
9. ISSUED BY
13b. RATING
14. METHOD OF SOLICITATION
CODE
15. DELIVER TO 16. ADMINISTERED BY CODE
18a. PAYMENT WILL BE MADE BY CODE17a. CONTRACTOR/
OFFEROR
CODE
FACILITY
CODE
CODE
TELEPHONE NUMBER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN
OFFER
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK
BELOW IS CHECKED
REQUEST
FOR QUOTE
(RFQ)
INVITATION
FOR BID
(IFB)
REQUEST
FOR
PROPOSAL
(RFP)
SEE ADDENDUM
19.
ITEM NUMBER
20.
SCHEDULE OF SUPPLIES/SERVICES
21.
QUANTITY
22.
UNIT
23.
UNIT PRICE
24.
AMOUNT
(Use Reverse and/or Attach Additional Sheets as Necessary)
25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Government Use Only)
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH
AND DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND
ON ANY ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS
SPECIFIED
29. AWARD OF CONTRACT: REFERENCE OFFER
DATED . . YOUR OFFER ON SOLICITATION
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
30a. SIGNATURE OF OFFEROR/CONTRACTOR
30b. NAME AND TITLE OF SIGNER (Type or print) 30c. DATE SIGNED
31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)
31b. NAME OF CONTRACTING OFFICER (Type or print) 31c. DATE SIGNED
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 11/2021)
Prescribed by GSA - FAR (48 CFR) 53.212
10. THIS ACQUISITION IS UNRESTRICTED OR
NORTH AMERICAN
INDUSTRY CLASSIFICATION
STANDARD (NAICS):
SIZE STANDARD:
13a. THIS CONTRACT IS A
RATED ORDER UNDER
THE DEFENSE PRIORITIES
AND ALLOCATIONS
SYSTEM - DPAS (15 CFR 700)
SET ASIDE: % FOR:
11. DELIVERY FOR FREE ON
BOARD (FOB) DESTINATION
UNLESS BLOCK IS MARKED
SEE SCHEDULE
12. DISCOUNT TERMS
ARE ARE NOT ATTACHED
ARE ARE NOT ATTACHED
27a. SOLICITATION INCORPORATES BY REFERENCE (FEDERAL ACQUISITION REGULATION) FAR 52.212-1, 52.212-4. FAR 52.212-3
AND 52.212-5 ARE ATTACHED. ADDENDA
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA
8(A)
ECONOMICALLY
DISADVANTAGED
WOMEN-OWNED SMALL
BUSINESS (EDWOSB)
SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
(SDVOSB)
HUBZONE SMALL
BUSINESS
SMALL BUSINESS
NOTE: OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30.
calls)
Section A - Solicitation/Contract Form
FY26 facility upgrades for various Joint Recruiting FacilitiesInstrument Name:
Product Service Code : Z1AA
W912DS26QA0160002
Section B - Supplies or Services & Prices or Costs
Additional Information/Notes
Item Supplies/Service Quanti ty
Unit Unit Price Amount
0001 US Armed Forces Career Center - 1306-1308 Ulster Avenue, Kingston, NY. INSTALL EXTERIOR
PYLON CABINET SIGN WITH
PHOTO/CELL TIMER EXTERIOR
SIGNS GRAPHICS GENERAL -
INSTALL EXTERIOR PYLON
CABINET SIGN(S) TO INCLUDE
PHOTOCELL/TIMER EA 1
Upgrade Explanation/Details pylon sign EXTERIOR SIGNS
GRAPHICS GENERAL - REPLACE
FACIA CHANNEL LETTER SIGN
(IN Upgrade Explanation/Details new facia sign
Product Service Code: Z1AA
Pricing Arrangement: Firm Fixed Price
1 Job
0002 Army office - Mount Royal Plaza, 959 Route 9, Queensbury, NY
FLOORING GENERAL - INSTALL
PORCELAIN TILES; RESTROOMS
- Flooring general - install porcelain tiles; restrooms SF 162 Flooring - General parameters: All floor areas will be of a common level, finished in a specified material and have a minimum live-load capacity of 50 pounds per square foot. a.
Porcelain Tiles: See ENCLOSURE
1 Job
#2, including ordering instructions, for a typical floor tile pattern, including tile color / name, grout color / name, and tile transition designations. See specific Military Service Attachment for their requirement. 1. Common Hallway / Corridor / Security Closets and Restroom Areas: Porcelain tile with unpolished, non-slip surface shall be installed in the hallways, corridors, security closets, and restroom area floors.
Product Service Code: Z1AA
Pricing Arrangement: Firm Fixed Price
0003 Army Recruiting 21 Aviation Road, Albany, NY SPECIAL
APPLICATIONS - INSTALL VIDEO
INTERCOM ENTRY CONTROL
SYSTEM SPECIAL
APPLICATIONS GENERAL - Install Video Intercom Entry Control System (Up to 8 Video Desk Station Phones or 4 Separate Door Station Entrances) to be used at Stand Alone - Single Service OR Collocated Services w/SEPARATE ENTRANCES Locations. Upgrade Explanation/Details: Replace the existing system with the new updated model.
Product Service Code: Z1AA
Pricing Arrangement: Firm Fixed Price
1 Job
0004 Marines Officer Selection Station - 2021 Western Avenue, Albany, NY
SPECIAL APPLICATIONS -
INSTALL VIDEO INTERCOM
ENTRY CONTROL SYSTEM
SPECIAL APPLICATIONS
GENERAL - Install Video Intercom Entry Control System (Up to 3 Video Desk Station Phones or 1 Separate Door Station Entrances) to be used at Stand Alone - Single Service OR Collocated Services w
/SEPARATE ENTRANCES
Locations. Upgrade Explanation /Details: Replace the existing system with the new updated model.
Product Service Code: Z1AA
Pricing Arrangement: Firm Fixed Price
1 Job
0005 Navy Office - 63 Market Street Potsdam, NY INSTALL CARPET
TILES & VINYL COMPOSITION
TILE, WALLS GENERAL, DOORS
GENERAL, INSTALL INTERIOR
WALL GRAPHICS
Product Service Code: Z1AA
Pricing Arrangement: Firm Fixed Price
1 Job
0006 Navy office - 1726 Black River Blvd., Rome, NY FLOORING GENERAL and DOORS GENERAL
1 Job
FLOORING GENERAL - Install Carpet Tiles; Interior Office Area(s)
SY 128 DOORS GENERAL
(EXTERIOR AND INTERIOR) -
Replace doorstop(s) DOORS
GENERAL (EXTERIOR AND
INTERIOR) - Replace interior doors
EA 2 DOORS GENERAL
(EXTERIOR AND INTERIOR) -
Replace solid door (to common area
(s) from office only) EA 1 DOORS
GENERAL (EXTERIOR AND
INTERIOR) - Repair door trim casing EA 3 DOORS GENERAL
(EXTERIOR AND INTERIOR) -
Install exterior entry door anti-Pry Plate EA 1 DOORS GENERAL
(EXTERIOR AND INTERIOR) -
REPAIR REAR EXIT STEEL DOOR
AND FRAME (TO OUTSIDE OF
BLDG; FIRE RATED) NO
HARDWARE
Product Service Code: Z1AA
Pricing Arrangement: Firm Fixed Price
Section C - Description/Specifications/Statement of Work
SCOPE OF WORK
UPSTATE NEW YORK FY26 Upgrades
GENERAL DESCRIPTION: The contractor shall provide all labor, material, equipment, and supervision to accomplish this FY 2026 Upgrade Request for the following locations and military services:
Army Medical Command
21 Aviation Road
Albany (Albany County)
NY
Army Recruiting
1306-1308 Ulster Ave
Kingston (Ulster County)
NY
Navy Recruiting
63 Market Street
Potsdam (St. Lawrence County)
NY
Army Recruiting
Mounty Royal 959 Rt 9
Queensbury (Warren County)
NY
Navy Recruiting
1726 Black River Blvd
Rome (Oneida County)
NY
(see below) Completion date after award date is 90 Days. Work must start at time of contract award.
a.Selected Contractor must visit site before submitting their Bid Price.
b.Selected Contractor must complete this job no later than 90 Days at contract award.
c.Selected Contractor must complete this job during normal business hours (9am 5pm) inthe presence of an authorized military personnel. Under no circumstances will a contractorbe given keys or access codes to the facility.
d.Selected Contractor must remove and dispose (from premises) all existing materials.
e.Selected Contractor will contact Jane Arnold, email; jane.e.arnold@usace.army.mil or 917-647- 0037 and provide a work schedule before gaining access to the Installation.
f.Selected Contractor will secure work site before, during and after work job.
g.Selected Contractor must clean up after completing the job.
h.Selected Contractor must have legal and authorized personnel to perform this job. However,no security clearance is required.
i.Selected Contractor must relocate furniture and other items, within the center of the officespace, storage room and/or testing room; however, storage and testing room should not beblocked from future access. Contractors are responsible for moving and replacing allfurniture and equipment including the wall artwork back to their original location.
j.Upon request from the Army Corps of Engineers, Owners/Property Manager, the selectedcontractor must provide insurance bond. (AMOUNT TO BE DETERMINDED BY OWNER, IFREQUIRED OR REQUESTED) in the owner s name.
k.Selected Contractor will contact Jane Arnold, email; jane.e.arnold@usace.army.mil or 917-647- 0037 (the POC) for full inspection after completion. Payments will not be released untilthe work is fully done and inspected.
l.Selected Contractor will be paid within 30 days after work is completed and inspected.
Army Recruiting 21 Aviation Road, Albany, NY
ITEM 0001A: SPECIAL APPLICATIONS INSTALL VIDEO INTERCOM ENTRY CONTROL
SYSTEM
SPECIAL APPLICATIONS GENERAL - Install Video Intercom Entry Control System (Up to 8 Video Desk Station Phones or 4 Separate Door Station Entrances) to be used at Stand Alone - Single Service OR Collocated Services w/SEPARATE ENTRANCES Locations.
Upgrade Explanation/Details: Replace the existing system with the new updated model.
Marines Officer Selection Station 2021 Western Avenue, Albany, NY
ITEM 0002A: SPECIAL APPLICATIONS INSTALL VIDEO INTERCOM ENTRY CONTROL
SYSTEM
SPECIAL APPLICATIONS GENERAL - Install Video Intercom Entry Control System (Up to 3 Video Desk Station Phones or 1 Separate Door Station Entrances) to be used at Stand Alone - Single Service OR Collocated Services w/SEPARATE ENTRANCES Locations.
Upgrade Explanation/Details: Replace the existing system with the new updated model.
Video Intercom Entry Control (EC) and CCTV / NVR systems. If existing, the current building system(s) must meet or exceed all the referenced specifications below, to be acceptable. A Certified Integrator / Installer per manufacturer is required for extended warranty periods and trouble-free installations for Aiphone, Hanwha (Certified Video Professional / Wisenet Certified Professional (WCP)), ASSA ABLOY, and most other listed equipment manufacturers.
REQUIRED BY LAW: For all supplied communication requirements and electronic security applications, the Lessor (or their contractors) are PROHIBITED (2019 N.D.A.A. law) from providing to the Government any such equipment or services as a substantial or essential component, or as critical technology as part of any system. These PROHIBITED security / telecommunications products are from any of the following source entities, any subsidiary or affiliate of such source entities: 1) The People s Republic of China; 2) Huawei Technologies Company; 3) ZTE Corporation; 4) Hytera Communications Corporation, Hangzhou Hikvision Digital Technology Company; 5) or Dahua Technology Company. Lessor (or contractors) must certify the equipment is not from any of these sources and provide written confirmation to the COE Representative prior to installation. Lessor (or contractors) must certify the equipment is not from any of these sources and provide written confirmation to the COE Representative prior to installation. Upon acceptance of the premises, the Lessor or Contractor must re-certify in writing what equipment has been installed, and that all components comply with the 2019 N.D.A.A. requirements.
All supplied / installed components / equipment to be from authorized dealers, and shall be equal to or exceed the performance of the models referenced below.
Video Intercom Entry Control (EC) System (Aiphone IXG Series):
A surface mounted door-entrance station (or keypad) shall be installed at the EXTERIOR PRIMARY-ENTRANCE and SECONDARY EGRESS doors to the military recruiting station as identified on the approved floor plan / AE drawings. Contractor will contact Aiphone and advise the COE before bid submittal of any unique site / office layout requirements which will impact their bid proposal. A Certified Integrator / Installer per manufacturer is required for extended warranty periods and trouble-free installations for Aiphone, Hanwha (Certified Video Professional / Wisenet Certified Professional (WCP)), ASSA ABLOY, and most other listed equipment manufacturers.
The EC system components should include the following items in the table below as system components should include the following items in the table below - as VIDEO INTERCOM
ENTRY CONTROL (EC) SYSTEM COMPONENTS TABLE
Application:
Model / Skew # s:
Description:
Qty:
Notes:
Primary Entrance and/or Secondary Egress Doors
IXG-DM7-HIDA
Aiphone - IXG System Door-Entrance Station (with mounting bracket)
Ea
. See Note 1, 2, 3, 4, 5.
Door-Entrance Station Mount
SBX-IXGDM7
Aiphone - Surface Mount Box, Includes Rain Hood
Ea
Secondary Egress Doors (when no public access)
DK-26 SS
Securitron - Keypad with CPU Board/Controller
Ea
. Optional Rear Egress Only See Note 4, 11
Each Military Service Space
IXG-2C7
Aiphone - Desk-Tenant Station
2+
. See Note 1, 6
Each Military Service Space
MCW-S/B
Aiphone - Desk-Tenant Station Stand
Ea
Per Desk-Tenant Station
Security Board
IXG-MAA
Aiphone - Network Door Release Relay Adaptor
. Selective door release (allows Military Services to release specific doors)
IXG-MK
Aiphone - Guard Station (includes flush mount kit)
. See Note 12
FPO250-C8D8E2
LSP - Power Supply (hardwired on security board)
. 8 Door / 8 Lock, 20A, 12VDC
Primary Entrance and/or Secondary Egress Doors
DPS-M-GY
Securitron - Door Position Switch (Magnetic)
Ea
. Use DPS-W-GY for Wood Doors. Only required for shared / common area egress doors.
Security Board (in Security Cabinet)
GS752TPP-300NAS
NETGEAR 48 Port Primary PoE+ Switch
Ea
. 48 Port (expandable with another 24 or 48 port switch)
Security Board (in Security Cabinet)
GS524UP- 100NAS
NETGEAR 24 Port Optional / Secondary
PoE++ Switch
Ea
. 24 Port PoE++ Switch (See Note 5)
VIDEO INTERCOM ENTRY CONTROL (EC) NOTES:
1) REQUIRED FOR CONTRACTORS: a. Contractor MUST complete questionnaire form for Aiphone custom program configuration file, which will be provided to the contractor for each office via email.
b. Programming design questionnaire forms & information to be completed at: https://www.aiphone.
com/support/technical-support/aiphone-programming-questionnaire
2) See https://www.aiphone.com/products/ixg-series for IXG specifics and recruitingcenters@aiphone.com for installation details / questions at recruiting centers.
3) Certified Integrators / Installers (warranty):
a. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha
b. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/
c. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators
4) Door release time range: Default of 5-10 seconds for all electrified doors / key pads (IXG, DK- 26).
5) Door-entrance station cameras to be connected to the CCTV system and shown on service specific open area television only. These cameras and desk-tenant stations require a PoE+ Switch connection. A license is needed to record door entrance station camera. Either recordability or viewability with be an option but not both. If more than 48 ports (or PoE++ ports) are required, add on the optional / secondary PoE+ Switch.
6) Door-entrance station mounting: If possible, mount door-entrance station on the side of the mullion flush to the exterior window. Purpose would be to try to limit the ability for the entrance station from being pulled off of the storefront.
7) Desk-tenant stations to be installed in each Military Service facility (minimum of 2, maximum of
8) for each Military Service recruiter identified in paragraph A.4. See Air Force Attachment 4a for their desk-station requirements. Optional wall mounted desk-tenant stations should be placed free and clear of all Military Service accent walls (as identified on approved floor plan / AE drawings).
Wall Outlet (yellow data port jack) to desk-tenant station shall include an eight (8) foot yellow straight-through CAT 6 patch wire. In rare cases (as directed by a COE representative or on the approved floor plan / AE drawings) a wall mount for desk-tenant stations may be necessary (wall mount model = IXG-FMK-2C7).
8) See paragraph G.7 for Door Hardware Schedule & release components.
9) All stranded low voltage wire (exit device, keypad, and door position switch) will be 18 AWG stranded wire with label / tag at each end for easy identification and troubleshooting. See ENCLOSURE #6a, 6b, 6c, and 6d for EC example components, wiring and layout diagrams.
10) See paragraph K. for PoE+ Switch & LSP Power supply requirements (hardwired on security board).
11) See communications paragraph E and ENCLOSURE #1a, 1b, 1c and 1d for locations and colors of data port jacks and CAT 6 wires.
12) No Public Access Secondary Doors: A secondary egress door that only Recruiting personnel use to enter the station. Typically, the public or potential recruits do not access thru this door. The No public access doors only requires the Securitron DK-26 Keypad with controller (vs the Aiphone door-entrance station). If the secondary egress is just an emergency only egress where no parties typically than neither the DK-26 or Aiphone door-station will be needed.
13) Door position switches to activate shared egress door(s) chime(s). Primary shared egress doors shall have a single-tone (e.g. - ding ), and secondary shared egress door(s) shall have two-tones (e.g. - ding-dong ).
US Armed Forces Career Center 1306-1308 Ulster Avenue, Kingston, NY.
ITEM 0003A: INSTALL EXTERIOR PYLON CABINET SIGN WITH PHOTO/CELL TIMER
EXTERIOR SIGNS GRAPHICS GENERAL - INSTALL EXTERIOR PYLON CABINET SIGN(S) TO
INCLUDE PHOTOCELL/TIMER EA 1
Upgrade Explanation/Details pylon sign
EXTERIOR SIGNS GRAPHICS GENERAL - REPLACE FACIA CHANNEL LETTER SIGN (IN
Upgrade Explanation/Details new facia sign
Exterior Signage: If collocated, Brand Identity Sign will read Armed Forces Career Center and shall comply with local building code requirements and Lessor specific guidelines. The sign shall have LED technology and be fabricated and installed in accordance with the referenced graphic and design standards. Channel letter returns and raceway color to match building fa ade. Note: The COE will provide an EPS format file to the Lessor for sign fabrication. The sign will be the maximum size allowed by code.
Note: If appropriate, to achieve contrast to the building fa ade, white lettering may be substituted for red lettering.
a. Collocated offices (side by side entrances) are to receive the Armed Forces Career Center signage.
b. Signage requirements for single, stand-alone recruiting office, see specific Military Service Attachment-Exterior Signage.
c. If applicable, separate small individual exterior cabinet / box signs shall be provided above each individual Military Service entrance (on the fa ade or perpendicular to the door, hung from the covered walkway ceiling). These are in addition to the Armed Forces Career Center sign. These internally illuminated LED small entrance cabinet / box signs (or style approved by Lessor) shall identify, by single name, the appropriate Military Service at its respective entrance. Unless otherwise requested, the signs shall have a black, Lexan face with white Helvetica Condensed lettering.
d. All signs will function by use of a dusk to dawn light sensor. The Lessor shall ensure proper sign erection and electrical installation.
Navy Office 63 Market Street Potsdam, NY
ITEM 0004A: INSTALL CARPET TILES & VINYL COMPOSITION TILE, WALLS GENERAL,
DOORS GENERAL, INSTALL INTERIOR WALL GRAPHICS
FLOORING GENERAL - Install Carpet Tiles; Interior Office Area(s) SY 55
Upgrade Explanation/Details: Carpet is badly worn and must be replaced.
FLOORING GENERAL - REPLACE VINYL COMPOSITION TILE RESTROOMS SF 162
Upgrade Explanation/Details: Restroom area is degraded.
WALLS GENERAL - REPLACE WOOD PANELING WITH INTERIOR GYPSUM WALLBOARD,
INCLUDING FINISH AND PAINT SF1199
Upgrade Explanation/Details: Closest storage is all wood paneling and needs to be replaced.
WALLS GENERAL - INSTALL CHAIR RAIL (INTERIOR OFFICE AREA(S) ONLY) TO INCL PAINT
/STAIN LF 133
Upgrade Explanation/Details: No chair rail is installed.
INTERIOR SIGNAGE GRAPHICS GENERAL - Install Navy "Training" Vinyl Graphic EA 1
Upgrade Explanation/Details: No graphic on wall
INTERIOR SIGNAGE GRAPHICS GENERAL - Install Navy "Honor, Courage, Commitment" Vinyl Graphic EA 1
Upgrade Explanation/Details: No graphic on wall.
Army Mount Royal Plaza, 959 Route 9 Queensbury, NY
ITEM 0005A: INSTALL PORCELAIN TILES, RESTROOMS
FLOORING GENERAL - Install porcelain tiles; restrooms SF 162
Upgrade Explanation/Details: Bathroom needs floor
Navy office 1726 Black River Blvd, Rome, NY
ITEM 0006A: INSTALL FLOORING, REPAIR/REPLACE INTERIOR & EXTERIOR DOORS
FLOORING GENERAL - Install Carpet Tiles; Interior Office Area(s) SY 128
Upgrade Explanation/Details: Old carpet that is stained and needs to be replaced.
DOORS GENERAL (EXTERIOR AND INTERIOR) - REPLACE DOORSTOP(S) EA 3
Upgrade Explanation/Details: All doors need doorstops.
DOORS GENERAL (EXTERIOR AND INTERIOR) - REPLACE CLOSET DOORS EA 2
Upgrade Explanation/Details: Doors to the testing room and storage areas are damaged and need to be replaced.
DOORS GENERAL (EXTERIOR AND INTERIOR) - REPLACE SOLID DOOR (TO COMMON
AREA(S) FROM OFFICE ONLY) EA 1
Upgrade Explanation/Details: Office door needs repair. Seems to be hollow.
DOORS GENERAL (EXTERIOR AND INTERIOR) - REPAIR DOOR TRIM CASING EA 3
Upgrade Explanation/Details: Once doors are replaced, they may require new casings.
DOORS GENERAL (EXTERIOR AND INTERIOR) - INSTALL EXTERIOR ENTRY DOOR ANTI-
PRY PLATE EA 1
Upgrade Explanation/Details: Back door had an attempted entry and needs a pry plate.
DOORS GENERAL (EXTERIOR AND INTERIOR) - REPAIR REAR EXIT STEEL DOOR AND
FRAME (TO OUTSIDE OF BLDG; FIRE RATED) NO HARDWARE EA 1
Upgrade Explanation/Details: If the door cannot be repaired, then replace
NAVY CARPET SCHEDULE
Manufacturer / Style:
Shaw / U.S. Navy Recruiting Standard: # 800G3
Color (Name, Number):
Water Garden, 69400
Product:
Carpet Tile
Installation Method:
Monolithic (See Note #1)
Installation Adhesive:
"LokDots" Adhesive System
Note 1: Carpet tile installation to be installed monolithic with all arrows pointing in the left-direction upon walking into the entrance of the space.
Note 2: If selected, for expedited delivery - government pricing contact: Shaw Contract for ALL inquiries go to website: www.shawcontract.com/usrecruiting. For pricing and order inquiries go to the pricing & ordering tab at the above website, or call: 1-800-356-7429 ext. 1 or email: cs.gsa@shawinc.com. For general inquiries call Michele Leise, 402-968-6025, email: michele.leise@shawcontract.com
Base Cove (for VCT & Carpet only): Johnsonite / Tarkett (https://distributor.tarkett.com), Rubber; Color: #40, Black, 4 H.
Flooring - General parameters: All floor areas will be of a common level, finished in a specified material and have a minimum live-load capacity of 50 pounds per square foot.
a. Porcelain Tiles: See ENCLOSURE. 8?.including.ordering.instructions, for a typical .oor tile pattern, including tile color / name, grout color / name, and tile transition designations. See speci.c Military Service Attachment for their requirement. 1. Common Hallway / Corridor / Security Closets and Restroom Areas: Porcelain tile with unpolished, non-slip surface shall be installed in the hallways, corridors, security closets, and restroom area .oors.
b. Chair Rail: Shall be installed on common area walls, excluding restrooms, and as referenced on the individual, Military Services finish schedule and approved floor plan / AE drawing. Chair rail to be mounted at bottom edge, 30 AFF, with semi-gloss paint finish. Profile to be Alexandria Molding:
AMH 300 1-1 / 16 x 3 , primed finger-jointed pine chair rail molding. See specific Military Services Attachments for their specific requirements. Note: Example of designated chair rail shown below:
Interior Signage: GS w/guidance: The Lessor shall order / install the Navy s Training Graphic and Honor, Courage, Commitment Graphic below. Graphics to be centered vertically between the ceiling and chair rail and horizontally scaled to 65% - 70% of the length of the wall. Each graphic is to be made as one-piece with the size of the graphic not to exceed 4 H x 18 L. COE representative to supply the Navy s wall graphic files. Lessor will coordinate with the COE on the installation of these self-adhesive, vinyl graphics or where applicable, rough-surface applications. Materials and instructions for installation are as follows:
a. Apply graphics to a flat smooth finish wall surface (after Navy paint is applied).
b. Allow paint a minimum of 7-10 days drying time before applying any wall graphics. Drying times will vary based on temperature and humidity.
c. Navy wall graphic shall be printed on and surface-applied to the self-adhesive vinyl. Printed Vinyl: 3M 180CV3-10 opaque white vinyl, surface ink jet printed with the Navy graphics. Surface laminated with 3M 8520 UV resistant matte clear overlay.
d. Alternate manufacturers (e.g., Arlon, Avery, GSP, OraCal, LG or other) sign vinyl materials equivalent to 3M 180 Series, rated for high bond wall application, and with minimum outdoor use 5-year warranty may be provided based on contractor recommendation.
e. Note 1: Wall mounted fixtures such as thermostats, wall switches, emergency lighting, and light sensors, etc., should be placed free and clear of all Military Service accents walls and graphics.
f. If selected, for expedited delivery-government pricing contact:
Manufacturer: Fastsigns, Inc.
POC: Chip Fullerton General Manager.
Phone: (901) 725-7446
Email: 81@fastsigns.com
Model: 3M 180CV3-10 Opaque White Vinyl wall covering
Substrate: Equal to 3M 180CV3-10 Opaque White Vinyl wall covering or better.
Installation: Utilize manufacturers recommended products in accordance with
3M 180CV3-10 Opaque White Vinyl wall covering installation instructions and surface preparation and adhesive guidelines. Clean the wall with a mixture of 70 percent isopropyl alcohol and 30 percent water. Do this two times. Cleaning with this mixture will increase adhesion on Low VOC paints.
Lessor to install the graphics according to manufacturer instructions in order to maintain their warranty requirements.
Graphics: a) Training Wall Graphic to be installed per approved floor plan / AE drawing:
A picture containing text, indoor, ceiling, airport
AI-generated content may be incorrect.
b) Honor, Courage, Commitment Wall Graphic to be installed per approved floor plan / AE drawing (opposite the Training Graphic):
A picture containing text, indoor, screenshot
AI-generated content may be incorrect.
Interior Doors: Shall be a flush panel solid core wood door with maple veneer and Grade 2 hardware or better.
1. Frames / Glass / Finish: i. Interior door and window frames to be Timely manufactured steel Classic S-Series (445) frames with factory applied Alumatone finish (not painted).
ii. Door color to be stained MinWax, Red Chestnut #232 (on all sides) with two (2) coats of polyurethane matte finish to be applied to stained areas.
iii. Doors requiring a full-length glass inset (low profile lite kit [24 x 60 ] with tempered glass), shall color match the Timely manufactured steel frames (factory applied Alumatone color SC108) or brushed stainless steel finish.
**USE THE APPLICABLE SPECIFICATION FOR THE TYPE OF DOOR BEING REPAIRED**
The following door opening hardware schedule and specifications shall apply:
Secondary Egress Doors: Steel doors and frames are required unless building aesthetics / standards only allow glass / other door types.
b. Interior Doors: Shall be a flush panel solid core wood door with maple veneer and Grade 2 hardware or better.
2. Frames / Glass / Finish: i. Interior door and window frames to be Timely manufactured steel Classic S-Series (445) frames with factory applied Alumatone finish (not painted).
ii. Door color to be stained MinWax, Red Chestnut #232 (on all sides) with two (2) coats of polyurethane matte finish to be applied to stained areas.
iii. Doors requiring a full length glass inset (low profile lite kit [24 x 60 ] with tempered glass), shall color match the Timely manufactured steel frames (factory applied Alumatone color SC108) or brushed stainless steel finish.
c. The following door opening hardware schedule and specifications shall apply: A Certified Integrator / Installer per manufacturer is required for extended warranty periods and trouble-free installations for Aiphone, Hanwha (Certified Video Professional / Wisenet Certified Professional (WCP)), ASSA ABLOY, and most other listed equipment manufacturers.
Door Openings (Doors / Hardware) Schedule & Specifications
EXTERIOR:
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Primary Entrance Door Single Aluminum:
N/A
Building Standard w/Glass Door
1- x 36 x 84
Match Building Standard
N/A
E1, E2
. Notes 1, 3 and 4
Primary Entrance Door Double Aluminum:
N/A
Building Standard w/Glass Door
1- x 36 x 84 (Ea)
Match Building Standard
N/A
E8
. Notes 1, 3 and 4
Secondary Egress Single Door(s):
N/A
Hollow Metal Core
1- x 36 x 84
See Paint Schedule
N/A
E3, E4
. Notes 1, 3 and 4
Secondary Egress Double Door(s):
N/A
Hollow Metal Core
1- x 36 x 84 (Ea)
See Paint Schedule
N/A
Similar to: E8, E9 or E10
. Notes 1, 3 and 4 Adjust as needed.
INTERIOR:
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Military entrance / egress, commander s office, conference / multi-purpose room, test / interview
N/A
Wood Door w-Full Length Glass Inset
1- x 36 x 80
See Notes
N/A
I1, I2, I3, I4, and I5, Notes 2, 3, and 4
General Door (service to internal common area, restroom, storage, janitorial, mechanical)
N/A
Wood Door
1- x 36 x 80
See Notes
N/A
I6, I8, I9, and I10
Notes 2, 3, and 4
Security Closet Door
N/A
Wood Door (Options):
Solid ~ Louvered Inset ~ Pocket Door
1- x 36 x 80
See Notes
N/A
I7a, I7b, and I7c
Notes 2, 3, and 4
HARDWARE SET DESCRIPTIONS:
EXTERIOR:
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Single Aluminum Exterior Door
8801EL36-24
Adams Rite - Rim Exit Device
2-5/8 x 36
Satin Aluminum
E1
55-56-PE8504F NEL (at stiles less than 4.5 )
55-56-PE8804F WEL (at stiles 4.5 or more)
Sargent Rim Exit Device with Motorized Latch Retraction
Nightlatch, key retracts latch.
Select model by verifying stile width.
36 wide
Other widths available.
Satin Stainless Steel
.PE80 for secondary egress w/ keypad
A620-626
Yale Cylinder Housing & Interchangeable Core (7-Pin)
N/A
Satin Chrome
MS4043-00-130
Adams Rite - Guard Ring
N/A
Clear Anodized
4612-1
Adams Rite - Power Transfer
N/A
Chrome
BF158-630
Rockwood - Door Pull
1 x 12
Satin SS
Match Existing building color
3531-689
Yale - Automatic Door Closer
2-1/8 x 12
Aluminum
BLP-210 (outswing)
DON-JO - Security Latch Guard (Anti-Pry Plate)
10 x 3.25 (outswing)
Match Existing
Conform to existing door configuration (e.g., offset, door handle, etc.)
DPS-M-GY
Securitron - Door Position Switch (Magnetic)
Gray
. Only required for shared / common area egress doors.
IXG-DM7-HIDA
Aiphone - IXG System Door-Entrance Station
13-11/16 H x 7-3/16 W x 2 D
SS
. (with mounting bracket)
SBX-IXGDM7
Aiphone - Surface Mount Box, Includes Rain Hood
13-3/4 H x 7-5/16 W x 3-1/16 D
SS
DK-26
Securitron - Keypad with CPU Board/Controller
1-1/2 W x 7 H x 7/8 D
SS
. Optional Rear Egress Only w/o Public Access
FPO250-C8D8E2
LSP - Power Supply
12 W x 14 H x 4.5 D
Black
. 8 Door / 8 Lock, 20A, 12VDC
(hardwired on security board)
Single Aluminum Exterior Door Emergency Egress ONLY. No door pull.
* - NOT the standard Secondary Egress.
PE8510F (at stiles less than 4.5 )
PE8810F (at stiles 4.5 or more)
Sargent Rim Exit Device
Exit only no outside trim or key override
Select model by verifying stile width.
36 wide
Other widths available.
Satin Stainless Steel
E2
If exterior inswing door consult with COE.
A620-626
Yale Cylinder Housing & Interchangeable Core
Satin Chrome
MS4043-00-130
Adams Rite - Guard Ring
N/A
Clear Anodized
3531-689
Yale - Automatic Door Closer
2-1/8 x 12
Aluminum
BLP-210 (outswing)
DON-JO - Security Latch Guard (Anti-Pry Plate)
10 x 3.25 (outswing)
Match Existing
Conform to existing door configuration (e.g., offset, door handle, etc.)
DPS-M-GY
Securitron - Door Position Switch (Magnetic)
Gray
. Only required for shared / common area egress doors.
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Single Hollow Metal/Wood Exterior Door
8701EL36-24
Adams Rite - Rim Exit Device
2-5/8 x 36
Satin Aluminum
E3
. 3701-36 for fire rated doors
55-56-PE8504F NEL (at stiles less than 4.5 )
55-56-PE8804F WEL (at stiles 4.5 or more)
Sargent Rim Exit Device with Motorized Latch Retraction
Nightlatch, key retracts latch.
Include shim kits as needed for glass moldings.
Select model by verifying stile width.
36 wide
Other widths available.
Satin Stainless Steel
.PE80 for secondary egress w/ keypad
A620-626
Yale Cylinder Housing & Interchangeable Core
N/A
Satin Chrome
MS4043-00-130
Adams Rite - Guard Ring
N/A
Clear Anodized
4612-1
Adams Rite - Power Transfer
N/A
Chrome
BF158-630
Rockwood - Door Pull
1 x 12
Satin SS
Match Existing building color
3531-689
Yale - Automatic Door Closer
2-1/8 x 12
Aluminum
BLP-210 (outswing)
DON-JO - Security Latch Guard (Anti-Pry Plate)
10 x 3.25 (outswing)
Match Existing
Conform to existing door configuration (e.g., offset, door handle, etc.)
DD01-180ULSN
NuK3y - Peephole (220 Viewing Angle)
1-1/16 x
1-3/8 ~ 2-1/4
Satin Nickel Gray
9/16 Hole
Install height @
5'-0" AFF
IXG-DM7-HIDA
Aiphone - IXG System Door-Entrance Station
13-11/16 H x 7-3/16 W x 2 D
SS 1
. (with mounting bracket)
SBX-IXGDM7
Aiphone - Surface Mount Box, Includes Rain Hood
13-3/4 H x 7-5/16 W x 3-1/16 D
SS
DK-26
Securitron - Keypad with CPU Board/Controller
1-1/2 W x 7 H x 7/8 D
SS
. Optional Rear Egress Only w/o Public Access
FPO250-C8D8E2
LSP - Power Supply (hardwired on security board)
12 W x 14 H x 4.5 D
Black
. 8 Door / 8 Lock, 20A, 12VDC
Single Hollow Metal/Wood Exterior Door Emergency Egress ONLY. No door pull.
* - NOT the standard Secondary Egress.
PE8510F (at stiles less than 4.5 )
PE8810F (at stiles 4.5 or more)
Sargent Rim Exit Device
Exit only no outside trim or key override.
Include shim kits as needed for glass moldings.
Select model by verifying stile width.
36 wide
Other widths available
Satin Aluminum
E4
A620-626
Yale Cylinder Housing & Interchangeable Core
N/A
Satin Chrome
MS4043-00-130
Adams Rite - Guard Ring
N/A
Clear Anodized
3531-689
Yale - Automatic Door Closer
2-1/8 x 12
Aluminum
DD01-180ULSN
NuK3y - Peephole (220 Viewing Angle)
1-1/16 x
1-3/8 ~ 2-1/4
Satin Nickel
9/16 Hole
Install height @
5'-0" AFF
BLP-210 (outswing)
DON-JO - Security Latch Guard (Anti-Pry Plate)
10 x 3.25 (outswing)
Match Existing
Conform to existing door configuration (e.g., offset, door handle, etc.)
DPS-M-GY
Securitron - Door Position Switch METAL (Magnetic)
Gray
. DPS-W-GY for Wood Doors Only required for shared / common area egress doors.
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Double Aluminum Exterior Door (both active leaf s, one electrified)
8801EL36-24
Adams Rite - Rim Exit Device
2-5/8 x 36
Satin Aluminum
E8 . Optional Rear
8801-36
Adams Rite - Rim Exit Device
2-5/8 x 36
Satin Aluminum
55-56-PE8504F NEL x PE8510F x L980A mullion (at stiles less than 4.5 )
55-56-PE8804F WEL x PE8810F x L980S mullion (at stiles 4.5 or more)
Sargent Pair of Rim Exit Device with Motorized Latch Retraction one leaf.
Nightlatch, key retracts latch at active leaf. Exit only inactive. Keyed removable mullion.
Select model by verifying stile width.
36 wide
Other widths available
Satin Stainless Steel
.PE80 for secondary egress w/ keypad
A620-626
Yale Cylinder Housing & Interchangeable Core
N/A
Satin Chrome
4612-1
Adams Rite - Power Transfer
N/A
Chrome
BF158-630
Rockwood - Door Pull
1 x 12
Satin SS
On electrified door. Match Existing building color
3531-689
Yale - Automatic Door Closer
2-1/8 x 12
Aluminum
MS4043-00-130
Adams Rite - Guard Ring
N/A
Clear Anodized
3890-10-628
Adams Rite Removable Mullion for 8800 Series Exit Devices
N/A
Clear Anodized
DPS-M-GY
Securitron - Door Position Switch (Magnetic)
Gray
. Only required for shared / common area egress doors.
IXG-DM7-HIDA
Aiphone - IXG System Door-Entrance Station
13-11/16 H x 7-3/16 W x 2 D
SS
. (with mounting bracket)
SBX-IXGDM7
Aiphone - Surface Mount Box, Includes Rain Hood
13-3/4 H x 7-5/16 W x 3-1/16 D
SS SS
DK-26
Securitron - Keypad with CPU Board/Controller
1-1/2 W x 7 H x 7/8 D
FPO250-C8D8E2
LSP - Power Supply (hardwired on security board)
12 W x 14 H x 4.5 D
Black
. 8 Door / 8 Lock, 20A, 12VDC
INTERIOR:
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Service Interior Entrance Doors (w/in Gov t controlled leased premises):
Varies
Solid Core Flush Wood Door & Full Length Glass Inset
1- x 36 x 80
See Notes
Ea
I1
Notes 2, 3 and 4
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
N/A
Satin Chrome
K1050-CSK-630
Rockwood Kick Plate
Satin SS
Riviera-G8-034
Hunter Douglas Riviera Commercial Aluminum Horizontal Blinds (cordless)
Brushed Aluminum
Note 2
Service Interior Secondary Egress Door (w/in Gov t controlled leased premises) if applicable:
Varies
Solid Core Flush Wood Door
1- x 36 x 80
See Notes
Ea
I2
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
Satin Chrome
K1050-CSK-630
Rockwood Kick Plate
Satin SS
DD01-180ULSN
NuK3y - Peephole (220 Viewing Angle)
1-1/16 x
1-3/8 ~ 2-1/4
Satin Nickel
9/16 Hole
Install height @
5'-0" AFF
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Station Commander Office Door(s):
Varies
Solid Core Flush Wood Door & Full Length Glass Inset
1- x 36 x 80
See Notes
Ea
I3
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
N/A
Satin Chrome
Test & Interview Room Door:
Varies
Solid Core Flush Wood Door & Full Length Glass Inset
1- x 36 x 80
See Notes
Ea
I4
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
B-TB-4601LN-626
Yale Passage Latch
N/A
Satin Chrome
B-UB-4601LN-626 if local code requires return
Multipurpose / Conference Room
Door(s) if applicable:
Varies
Solid Core Flush Wood Door
1- x 36 x 80
See Notes
Ea
I5
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
N/A
Satin Chrome
Storage Room Door:
Varies
Solid Core Flush Wood Door
1- x 36 x 80
See Notes
Ea
I6
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
N/A
Satin Chrome
Security Closet Door (Standard):
Varies
Solid Core Flush Wood Door
1- x 36 x 80
See Notes
Ea
I7a
Standard Door
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
Application:
Model / Skew # s:
Description:
Size:
Finish:
Qty:
Set Codes:
Notes:
Security Closet Door (Full Louvered Inset):
Varies
Solid Core Flush Wood Door & Full Length Louvered Inset
1- x 36 x 80
See Notes
Ea
I7b
Louvered Door (Option)
Classic S-Series(Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
N/A
Satin Chrome
2701 R/PA- 689
Yale - Automatic Door Closer
2-1/8 x 12
Aluminum
Security Closet Door (Pocket):
Varies
Solid Core Flush Wood POCKET Door
1- x 36 x 80
See Notes
Ea
I7c
Required for Air Force HUB Offices
PF28200A7280
Pemko - Pocket Door Hardware
N/A
N/A
2 x 4 Framing, With soft close / open
PF134KIT
Pemko - Pocket Door
Frame Kit
1- x 36 x 80
Chrome Plated
Ea
Kit for 1-3/4 doors within 2 x 4 Framing
P-Series TA-23
Timely Pocket Trim Kit
N/A
Alumatone
XGT-243- PD9653A-S7-32D-RH or LH-TT07
Inox PD96 Series Sliding, Self-Latching/Locking Mortise Entry Lock
N/A
Satin SS
Specify handing in order as RH or LH. If local code requires door handle return use XGT-244.
A600-626
Yale Interchangeable Core (7-Pin)
N/A
Chrome
N/A
Plywood Reinforcement
N/A
N/A
Ea plywood installed between pocket door studs for rigidity
Restroom Door(s):
Varies
Solid Core Flush Wood Door
1- x 36 x 80
See Notes
I8
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4602LN-626
Yale Privacy / Bath Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4602LN-626 if local code requires return
K1050-CSK-630
Rockwood Kick Plate
Satin SS
Janitorial Closet Door:
Varies
Solid Core Flush Wood Door
1- x 36 x 80
See Notes
Ea
I9
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
N/A
Satin Chrome
K1050-CSK-630
Rockwood Kick Plate
Satin SS
Mechanical Room Door(s) - if applicable
Varies
Solid Core Flush Wood Door
1- x 36 x 80
See Notes
Ea
I10
Classic S-Series (Timely Code 445)
Timely Manufactured Frame with pre-drilled holes & silencers
36 x 80
Alumatone
Ea
Door & window frames to match
TA2714-USA-US26D
McKinney - Hinges
4-1/2 x 4-1/2
Satin Chrome
B-TB-4607LN-626
Yale Entry Lever Cylinder Lockset
N/A
Satin Chrome
B-UB-4607LN-626 if local code requires return
A600-626
Yale SFIC Core (7-Pin)
N/A
Satin Chrome
NOTES & ADDITIONAL REQUIREMENTS FOR EXTERIOR & INTERIOR DOORS &
HARDWARE:
1) Exterior Egress Doors: a. Lessor Shell Requirements / Exterior Door Health Survey: Exterior door openings to the Government controlled space shall be surveyed to ensure a healthy, weather tight and fully functional door unit (door, frame, glass, and hardware). Door opening / swing to be outswing only, fail secure with Grade 1 hardware and no mail slots allowed. Existing mail slots in exterior doors shall be removed. Survey / coordinate hardware requirements on existing doors / frames to be re-used. Clean, repair or replace as necessary - advise COE representative if existing door / hardware needs to be replaced.
b. Door release time range: Default of 5-10 seconds for all electrified doors / key pads (IXG, DK- 26).
c. Hinge pins for exterior doors to be concealed / non-removable (existing to remain if meets requirements).
d. DON-JO Door Strengtheners: www.don-jo.com (door / hardware specific as needed for long term proper door usage (connectivity of video intercom entry control (EC) system components), As determined by EC system contractor (e.g. - wrap around plate; inactive door wrap around strike prep; hinge side wrap around reinforcement; mortise lock wrap around; door reinforcer [deadbolts & key-in-knob locks]).
e. See paragraph G.9.ii: Hunter Douglas Fixed Panel Shade (absolutely no mini-blinds on exterior doors).
f. See paragraph G.6. & G.7: 3M Fragment Retention Film (required for ALL glass in doors and windows on the perimeter of Government controlled leased premises).
g. Additional door types (non-standard / double doors / all glass Herculite doors) confirm with COE (located in Appendix C).
2) Interior Doors:
a. To be flush panel solid core wood door, maple veneer, stained with MinWax Red Chestnut #232 (all sides); with two (2) coats of polyurethane matte finish applied to stained areas.
b. Metal Frames (for doors & windows): Interior door and window frames to be Timely manufactured steel frames with factory applied Alumatone aluminum / silver finish (not painted).
For doors with a full length tempered glass inset (24 x 60 ), finish to match the Timely frames Alumatone aluminum / silver finish metal frame. See paragraph G.6. & G.7 for full details.
c. Grade 2 hardware or better required. Specifications are for no return handles. If required by local code, door handles with a return may be substituted.
d. Doors to include a Rockwood (403-626 satin chrome) convex rubber doorstop/bumper.
e. Security Closet ONLY Options: 1. Flush panel wood finished door.
2. Flush panel wood finished door with full length louvered inset if increased Security Closet ventilation is required.
3. Flush panel wood finished pocket door may be installed to minimize space requirements (no swing taking up space).
f. Mini-Blinds: Interior doors & windows to have mini-blinds, except for Test / Interview rooms. Must be secured at the bottom of doors with metal clips.
3) Certified Integrators / Installers (warranty):
a. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha
b. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/
c. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators
4) Keying or Re-Keying: Before.delivery.and.acceptance.of.the.premises?.all.previous.existing.
exterior.door=locks.shall.be.re=keyed. The Lessor will be responsible for coordinating with the COE on the number of new keys required to be furnished to each Military Service. EACH individual Military Service office shall be separately keyed. Note: Both front and rear exterior exit doors for each Military Service should be same-keyed. Keys to be minimized / same-keyed for each Military Services primary and secondary egress doors, interior common area doors, security closet and each Military Service specific interior doors (excluding Station Commanders Offices). Station Commanders Offices shall be separately keyed. If fire department Knox Box is required, a key must be provided. See also paragraph A.4 regarding the number of recruiters needing keys.
5) Acronym Legend: a. SS = Stainless Steel b. EA = Each c. . = Electrified component.
*** END OF NARRATIVE ***
Requirements FY26 facility upgrades for various Joint Recruiting Facilities
Section F - Deliveries or Performance
0001 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026
1 JobQuantity
Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA
W2SD ENDIST NEW YORK
KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY
10278-0004 UNITED STATES
0002 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026
1 JobQuantity
Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA
W2SD ENDIST NEW YORK
KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY
10278-0004 UNITED STATES
0003 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026
1 JobQuantity
Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA
W2SD ENDIST NEW YORK
KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY
10278-0004 UNITED STATES
0004 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026
1 JobQuantity
Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA
W2SD ENDIST NEW YORK
KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY
10278-0004 UNITED STATES
0005 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026
1 JobQuantity
Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA
W2SD ENDIST NEW YORK
KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY
10278-0004 UNITED STATES
0006 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026
1 JobQuantity
Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA
W2SD ENDIST NEW YORK
KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY
10278-0004 UNITED STATES
Section G - Contract Administration Data
DFARS Clauses Incorporated by Reference
Number Title Effective Date
Alternate Deviation
Variation Effective Date
252.201-7000 Contracting Officer's Representative.
1991-12
252.232-7003 Electronic Submission of Payment Requests and Receiving Reports.
2018-12
Section H - Special Contract Requirements
"General Decision Number: NY20260002 05/18/2026
State: New York
Construction Types: Building, Heavy and Highway
Counties: New York Counties of
Albany, Columbia, Fulton, Greene, Montgomery, Rensselaer, Saratoga, Schenectady, Schoharie and Washington
Excludes Building Construction in COLUMBIA, FULTON, GREENE & MONTGOMERY Counties
Modification Number Publication Date
1 01/30/2026
2 05/18/2026
ASBE0040-002 05/01/2025
Rates Fringes
HAZARDOUS MATERIAL HANDLER (DUTIES LIMITED TO
PREPARATION WETTING; STRIPPING; REMOVAL; SCRAPPING;
VACUUMING; BAGGING; AND DISPOSING OF ALL INSULATION
MATERIALS, WHETHER THEY CONTAIN ASBESTOS OR NOT
FROM MECHANCIAL SYSTEMS)............................$ 41.74 27.58
ASBESTOS/INSULATOR WORKER (SCOPE OF WORK: INCLUDES
APPLICATION OF ALL INSULATING MATERIALS,
PROTECTIVE, COVERINGS, COATING AND FINISHING TO
ALL TYPES OF MECHANICAL SYSTEMS.)...................$ 41.74 27.58
BOIL0197-002 01/01/2025
Rates Fringes
BOILERMAKER.........................................$ 43.34 27.66
BRNY0002-019 12/03/2025
Rates Fringes
BRICKLAYER (BRICKLAYERS, STONE MASONS, CEMENT
MASONS, PLASTERERS, POINTERS, CAULKERS & CLEANERS)..$ 41.79 22.33
CARP0279-006 07/01/2025
Rates…