Solicitation - W912DS26QA016.pdf

PDF 3 MB Posted

Attached to
FY26 Upgrades for Various Recruiting Stations
Solicitation number
W912DS26QA016
Issued by

About this file

Solicitation Summary: W912DS26QA016

This is a Solicitation document for FY26 Upgrades for Various Recruiting Stations issued by the Department of the Army Corps of Engineers Engineering District New York. The solicitation seeks contractors to provide upgrades and improvements to multiple U.S. Army recruiting stations during fiscal year 2026. The specific scope of work, detailed requirements, deliverables, performance standards, and evaluation criteria are contained within the attached Statement of Work (SOW). Contractors are expected to review both the solicitation document and SOW in their entirety to understand the full scope of required upgrades, which may encompass facility improvements, equipment installations, technology enhancements, or related infrastructure modifications at various recruiting station locations.

Interested contractors must submit proposals in accordance with the solicitation instructions and requirements. The specific response deadline, award date, pricing structure, contract type, small business set-asides (if applicable), and other administrative details are outlined in the complete solicitation package. Potential bidders should carefully review all attachment documents and the SOW to determine their capability to meet the Army's recruiting station upgrade requirements and to prepare competitive proposals.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WOMEN-OWNED SMALL

BUSINESS (WOSB)

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES

1. REQUISITION NUMBER PAGE 1 OF

2. CONTRACT NUMBER 3. AWARD/EFFECTIVE

DATE

4. ORDER NUMBER 5. SOLICITATION NUMBER 6. SOLICITATION ISSUE

DATE

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME b. TELEPHONE NUMBER (No collect 8. OFFER DUE DATE/

LOCAL TIME

9. ISSUED BY

13b. RATING

14. METHOD OF SOLICITATION

CODE

15. DELIVER TO 16. ADMINISTERED BY CODE

18a. PAYMENT WILL BE MADE BY CODE17a. CONTRACTOR/

OFFEROR

CODE

FACILITY

CODE

CODE

TELEPHONE NUMBER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN

OFFER

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK

BELOW IS CHECKED

REQUEST

FOR QUOTE

(RFQ)

INVITATION

FOR BID

(IFB)

REQUEST

FOR

PROPOSAL

(RFP)

SEE ADDENDUM

19.

ITEM NUMBER

20.

SCHEDULE OF SUPPLIES/SERVICES

21.

QUANTITY

22.

UNIT

23.

UNIT PRICE

24.

AMOUNT

(Use Reverse and/or Attach Additional Sheets as Necessary)

25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Government Use Only)

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH

AND DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND

ON ANY ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS

SPECIFIED

29. AWARD OF CONTRACT: REFERENCE OFFER

DATED . . YOUR OFFER ON SOLICITATION

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

30a. SIGNATURE OF OFFEROR/CONTRACTOR

30b. NAME AND TITLE OF SIGNER (Type or print) 30c. DATE SIGNED

31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)

31b. NAME OF CONTRACTING OFFICER (Type or print) 31c. DATE SIGNED

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 11/2021)

Prescribed by GSA - FAR (48 CFR) 53.212

10. THIS ACQUISITION IS UNRESTRICTED OR

NORTH AMERICAN

INDUSTRY CLASSIFICATION

STANDARD (NAICS):

SIZE STANDARD:

13a. THIS CONTRACT IS A

RATED ORDER UNDER

THE DEFENSE PRIORITIES

AND ALLOCATIONS

SYSTEM - DPAS (15 CFR 700)

SET ASIDE: % FOR:

11. DELIVERY FOR FREE ON

BOARD (FOB) DESTINATION

UNLESS BLOCK IS MARKED

SEE SCHEDULE

12. DISCOUNT TERMS

ARE ARE NOT ATTACHED

ARE ARE NOT ATTACHED

27a. SOLICITATION INCORPORATES BY REFERENCE (FEDERAL ACQUISITION REGULATION) FAR 52.212-1, 52.212-4. FAR 52.212-3

AND 52.212-5 ARE ATTACHED. ADDENDA

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA

8(A)

ECONOMICALLY

DISADVANTAGED

WOMEN-OWNED SMALL

BUSINESS (EDWOSB)

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

(SDVOSB)

HUBZONE SMALL

BUSINESS

SMALL BUSINESS

NOTE: OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30.

calls)

Section A - Solicitation/Contract Form

FY26 facility upgrades for various Joint Recruiting FacilitiesInstrument Name:

Product Service Code : Z1AA

W912DS26QA016

Section B - Supplies or Services & Prices or Costs

Additional Information/Notes

Item Supplies/Service Quanti ty

Unit Unit Price Amount

0001 Army Medical Command - 21 Aviation Road, Albany NY

Product Service Code: Z1AA

Pricing Arrangement: Firm Fixed Price

1 Job

0002 Army Recruiting - 1306-1308 Ulster Ave, Kingston NY

Product Service Code: Z1AA

Pricing Arrangement: Firm Fixed Price

1 Job

0003 Navy Recruiting - 63 Market Street, Potsdam NY

Product Service Code: Z1AA

Pricing Arrangement: Firm Fixed Price

1 Job

0004 Army Recruiting - Mounty Royal 959 Rt 9, Queensbury NY

Product Service Code: Z1AA

Pricing Arrangement: Firm Fixed Price

1 Job

0005 1 Job

Navy Recruiting - 1726 Black River Blvd, Rome NY

Product Service Code: Z1AA

Pricing Arrangement: Firm Fixed Price

Section C - Description/Specifications/Statement of Work

SCOPE OF WORK

UPSTATE NEW YORK FY26 Upgrades

GENERAL DESCRIPTION: The contractor shall provide all labor, material, equipment, and supervision to accomplish this FY 2026 Upgrade Request for the following locations and military services:

Army Medical Command

21 Aviation Road

Albany (Albany County)

NY

Army Recruiting

1306-1308 Ulster Ave

Kingston (Ulster County)

NY

Navy Recruiting

63 Market Street

Potsdam (St. Lawrence County)

NY

Army Recruiting

Mounty Royal 959 Rt 9

Queensbury (Warren County)

NY

Navy Recruiting

1726 Black River Blvd

Rome (Oneida County)

NY

(see below) Completion date after award date is 90 Days. Work must start at time of contract award.

a.Selected Contractor must visit site before submitting their Bid Price.

b.Selected Contractor must complete this job no later than 90 Days at contract award.

c.Selected Contractor must complete this job during normal business hours (9am 5pm) inthe presence of an authorized military personnel. Under no circumstances will a contractorbe given keys or access codes to the facility.

d.Selected Contractor must remove and dispose (from premises) all existing materials.

e.Selected Contractor will contact Jane Arnold, email; jane.e.arnold@usace.army.mil or 917-647- 0037 and provide a work schedule before gaining access to the Installation.

f.Selected Contractor will secure work site before, during and after work job.

g.Selected Contractor must clean up after completing the job.

h.Selected Contractor must have legal and authorized personnel to perform this job. However,no security clearance is required.

i.Selected Contractor must relocate furniture and other items, within the center of the officespace, storage room and/or testing room; however, storage and testing room should not beblocked from future access. Contractors are responsible for moving and replacing allfurniture and equipment including the wall artwork back to their original location.

j.Upon request from the Army Corps of Engineers, Owners/Property Manager, the selectedcontractor must provide insurance bond. (AMOUNT TO BE DETERMINDED BY OWNER, IFREQUIRED OR REQUESTED) in the owner s name.

k.Selected Contractor will contact Jane Arnold, email; jane.e.arnold@usace.army.mil or 917-647- 0037 (the POC) for full inspection after completion. Payments will not be released untilthe work is fully done and inspected.

l.Selected Contractor will be paid within 30 days after work is completed and inspected.

Army Recruiting 21 Aviation Road, Albany, NY

ITEM 0001A: SPECIAL APPLICATIONS INSTALL VIDEO INTERCOM ENTRY CONTROL

SYSTEM

SPECIAL APPLICATIONS GENERAL - Install Video Intercom Entry Control System (Up to 8 Video Desk Station Phones or 4 Separate Door Station Entrances) to be used at Stand Alone - Single Service OR Collocated Services w/SEPARATE ENTRANCES Locations.

Upgrade Explanation/Details: Replace the existing system with the new updated model.

Marines Officer Selection Station 2021 Western Avenue, Albany, NY

ITEM 0002A: SPECIAL APPLICATIONS INSTALL VIDEO INTERCOM ENTRY CONTROL

SYSTEM

SPECIAL APPLICATIONS GENERAL - Install Video Intercom Entry Control System (Up to 3 Video Desk Station Phones or 1 Separate Door Station Entrances) to be used at Stand Alone - Single Service OR Collocated Services w/SEPARATE ENTRANCES Locations.

Upgrade Explanation/Details: Replace the existing system with the new updated model.

Video Intercom Entry Control (EC) and CCTV / NVR systems. If existing, the current building system(s) must meet or exceed all the referenced specifications below, to be acceptable. A Certified Integrator / Installer per manufacturer is required for extended warranty periods and trouble-free installations for Aiphone, Hanwha (Certified Video Professional / Wisenet Certified Professional (WCP)), ASSA ABLOY, and most other listed equipment manufacturers.

REQUIRED BY LAW: For all supplied communication requirements and electronic security applications, the Lessor (or their contractors) are PROHIBITED (2019 N.D.A.A. law) from providing to the Government any such equipment or services as a substantial or essential component, or as critical technology as part of any system. These PROHIBITED security / telecommunications products are from any of the following source entities, any subsidiary or affiliate of such source entities: 1) The People s Republic of China; 2) Huawei Technologies Company; 3) ZTE Corporation; 4) Hytera Communications Corporation, Hangzhou Hikvision Digital Technology Company; 5) or Dahua Technology Company. Lessor (or contractors) must certify the equipment is not from any of these sources and provide written confirmation to the COE Representative prior to installation. Lessor (or contractors) must certify the equipment is not from any of these sources and provide written confirmation to the COE Representative prior to installation. Upon acceptance of the premises, the Lessor or Contractor must re-certify in writing what equipment has been installed, and that all components comply with the 2019 N.D.A.A. requirements.

All supplied / installed components / equipment to be from authorized dealers, and shall be equal to or exceed the performance of the models referenced below.

Video Intercom Entry Control (EC) System (Aiphone IXG Series):

A surface mounted door-entrance station (or keypad) shall be installed at the EXTERIOR PRIMARY-ENTRANCE and SECONDARY EGRESS doors to the military recruiting station as identified on the approved floor plan / AE drawings. Contractor will contact Aiphone and advise the COE before bid submittal of any unique site / office layout requirements which will impact their bid proposal. A Certified Integrator / Installer per manufacturer is required for extended warranty periods and trouble-free installations for Aiphone, Hanwha (Certified Video Professional / Wisenet Certified Professional (WCP)), ASSA ABLOY, and most other listed equipment manufacturers.

The EC system components should include the following items in the table below as system components should include the following items in the table below - as VIDEO INTERCOM

ENTRY CONTROL (EC) SYSTEM COMPONENTS TABLE

Application:

Model / Skew # s:

Description:

Qty:

Notes:

Primary Entrance and/or Secondary Egress Doors

IXG-DM7-HIDA

Aiphone - IXG System Door-Entrance Station (with mounting bracket)

Ea

. See Note 1, 2, 3, 4, 5.

Door-Entrance Station Mount

SBX-IXGDM7

Aiphone - Surface Mount Box, Includes Rain Hood

Ea

Secondary Egress Doors (when no public access)

DK-26 SS

Securitron - Keypad with CPU Board/Controller

Ea

. Optional Rear Egress Only See Note 4, 11

Each Military Service Space

IXG-2C7

Aiphone - Desk-Tenant Station

2+

. See Note 1, 6

Each Military Service Space

MCW-S/B

Aiphone - Desk-Tenant Station Stand

Ea

Per Desk-Tenant Station

Security Board

IXG-MAA

Aiphone - Network Door Release Relay Adaptor

. Selective door release (allows Military Services to release specific doors)

IXG-MK

Aiphone - Guard Station (includes flush mount kit)

. See Note 12

FPO250-C8D8E2

LSP - Power Supply (hardwired on security board)

. 8 Door / 8 Lock, 20A, 12VDC

Primary Entrance and/or Secondary Egress Doors

DPS-M-GY

Securitron - Door Position Switch (Magnetic)

Ea

. Use DPS-W-GY for Wood Doors. Only required for shared / common area egress doors.

Security Board (in Security Cabinet)

GS752TPP-300NAS

NETGEAR 48 Port Primary PoE+ Switch

Ea

. 48 Port (expandable with another 24 or 48 port switch)

Security Board (in Security Cabinet)

GS524UP- 100NAS

NETGEAR 24 Port Optional / Secondary

PoE++ Switch

Ea

. 24 Port PoE++ Switch (See Note 5)

VIDEO INTERCOM ENTRY CONTROL (EC) NOTES:

1) REQUIRED FOR CONTRACTORS: a. Contractor MUST complete questionnaire form for Aiphone custom program configuration file, which will be provided to the contractor for each office via email.

b. Programming design questionnaire forms & information to be completed at: https://www.aiphone.

com/support/technical-support/aiphone-programming-questionnaire

2) See https://www.aiphone.com/products/ixg-series for IXG specifics and recruitingcenters@aiphone.com for installation details / questions at recruiting centers.

3) Certified Integrators / Installers (warranty):

a. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha

b. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/

c. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators

4) Door release time range: Default of 5-10 seconds for all electrified doors / key pads (IXG, DK- 26).

5) Door-entrance station cameras to be connected to the CCTV system and shown on service specific open area television only. These cameras and desk-tenant stations require a PoE+ Switch connection. A license is needed to record door entrance station camera. Either recordability or viewability with be an option but not both. If more than 48 ports (or PoE++ ports) are required, add on the optional / secondary PoE+ Switch.

6) Door-entrance station mounting: If possible, mount door-entrance station on the side of the mullion flush to the exterior window. Purpose would be to try to limit the ability for the entrance station from being pulled off of the storefront.

7) Desk-tenant stations to be installed in each Military Service facility (minimum of 2, maximum of

8) for each Military Service recruiter identified in paragraph A.4. See Air Force Attachment 4a for their desk-station requirements. Optional wall mounted desk-tenant stations should be placed free and clear of all Military Service accent walls (as identified on approved floor plan / AE drawings).

Wall Outlet (yellow data port jack) to desk-tenant station shall include an eight (8) foot yellow straight-through CAT 6 patch wire. In rare cases (as directed by a COE representative or on the approved floor plan / AE drawings) a wall mount for desk-tenant stations may be necessary (wall mount model = IXG-FMK-2C7).

8) See paragraph G.7 for Door Hardware Schedule & release components.

9) All stranded low voltage wire (exit device, keypad, and door position switch) will be 18 AWG stranded wire with label / tag at each end for easy identification and troubleshooting. See ENCLOSURE #6a, 6b, 6c, and 6d for EC example components, wiring and layout diagrams.

10) See paragraph K. for PoE+ Switch & LSP Power supply requirements (hardwired on security board).

11) See communications paragraph E and ENCLOSURE #1a, 1b, 1c and 1d for locations and colors of data port jacks and CAT 6 wires.

12) No Public Access Secondary Doors: A secondary egress door that only Recruiting personnel use to enter the station. Typically, the public or potential recruits do not access thru this door. The No public access doors only requires the Securitron DK-26 Keypad with controller (vs the Aiphone door-entrance station). If the secondary egress is just an emergency only egress where no parties typically than neither the DK-26 or Aiphone door-station will be needed.

13) Door position switches to activate shared egress door(s) chime(s). Primary shared egress doors shall have a single-tone (e.g. - ding ), and secondary shared egress door(s) shall have two-tones (e.g. - ding-dong ).

US Armed Forces Career Center 1306-1308 Ulster Avenue, Kingston, NY.

ITEM 0003A: INSTALL EXTERIOR PYLON CABINET SIGN WITH PHOTO/CELL TIMER

EXTERIOR SIGNS GRAPHICS GENERAL - INSTALL EXTERIOR PYLON CABINET SIGN(S) TO

INCLUDE PHOTOCELL/TIMER EA 1

Upgrade Explanation/Details pylon sign

EXTERIOR SIGNS GRAPHICS GENERAL - REPLACE FACIA CHANNEL LETTER SIGN (IN

Upgrade Explanation/Details new facia sign

Exterior Signage: If collocated, Brand Identity Sign will read Armed Forces Career Center and shall comply with local building code requirements and Lessor specific guidelines. The sign shall have LED technology and be fabricated and installed in accordance with the referenced graphic and design standards. Channel letter returns and raceway color to match building fa ade. Note: The COE will provide an EPS format file to the Lessor for sign fabrication. The sign will be the maximum size allowed by code.

Note: If appropriate, to achieve contrast to the building fa ade, white lettering may be substituted for red lettering.

a. Collocated offices (side by side entrances) are to receive the Armed Forces Career Center signage.

b. Signage requirements for single, stand-alone recruiting office, see specific Military Service Attachment-Exterior Signage.

c. If applicable, separate small individual exterior cabinet / box signs shall be provided above each individual Military Service entrance (on the fa ade or perpendicular to the door, hung from the covered walkway ceiling). These are in addition to the Armed Forces Career Center sign. These internally illuminated LED small entrance cabinet / box signs (or style approved by Lessor) shall identify, by single name, the appropriate Military Service at its respective entrance. Unless otherwise requested, the signs shall have a black, Lexan face with white Helvetica Condensed lettering.

d. All signs will function by use of a dusk to dawn light sensor. The Lessor shall ensure proper sign erection and electrical installation.

Navy Office 63 Market Street Potsdam, NY

ITEM 0004A: INSTALL CARPET TILES & VINYL COMPOSITION TILE, WALLS GENERAL,

DOORS GENERAL, INSTALL INTERIOR WALL GRAPHICS

FLOORING GENERAL - Install Carpet Tiles; Interior Office Area(s) SY 55

Upgrade Explanation/Details: Carpet is badly worn and must be replaced.

FLOORING GENERAL - REPLACE VINYL COMPOSITION TILE RESTROOMS SF 162

Upgrade Explanation/Details: Restroom area is degraded.

WALLS GENERAL - REPLACE WOOD PANELING WITH INTERIOR GYPSUM WALLBOARD,

INCLUDING FINISH AND PAINT SF1199

Upgrade Explanation/Details: Closest storage is all wood paneling and needs to be replaced.

WALLS GENERAL - INSTALL CHAIR RAIL (INTERIOR OFFICE AREA(S) ONLY) TO INCL PAINT

/STAIN LF 133

Upgrade Explanation/Details: No chair rail is installed.

INTERIOR SIGNAGE GRAPHICS GENERAL - Install Navy "Training" Vinyl Graphic EA 1

Upgrade Explanation/Details: No graphic on wall

INTERIOR SIGNAGE GRAPHICS GENERAL - Install Navy "Honor, Courage, Commitment" Vinyl Graphic EA 1

Upgrade Explanation/Details: No graphic on wall.

Army Mount Royal Plaza, 959 Route 9 Queensbury, NY

ITEM 0005A: INSTALL PORCELAIN TILES, RESTROOMS

FLOORING GENERAL - Install porcelain tiles; restrooms SF 162

Upgrade Explanation/Details: Bathroom needs floor

Navy office 1726 Black River Blvd, Rome, NY

ITEM 0006A: INSTALL FLOORING, REPAIR/REPLACE INTERIOR & EXTERIOR DOORS

FLOORING GENERAL - Install Carpet Tiles; Interior Office Area(s) SY 128

Upgrade Explanation/Details: Old carpet that is stained and needs to be replaced.

DOORS GENERAL (EXTERIOR AND INTERIOR) - REPLACE DOORSTOP(S) EA 3

Upgrade Explanation/Details: All doors need doorstops.

DOORS GENERAL (EXTERIOR AND INTERIOR) - REPLACE CLOSET DOORS EA 2

Upgrade Explanation/Details: Doors to the testing room and storage areas are damaged and need to be replaced.

DOORS GENERAL (EXTERIOR AND INTERIOR) - REPLACE SOLID DOOR (TO COMMON

AREA(S) FROM OFFICE ONLY) EA 1

Upgrade Explanation/Details: Office door needs repair. Seems to be hollow.

DOORS GENERAL (EXTERIOR AND INTERIOR) - REPAIR DOOR TRIM CASING EA 3

Upgrade Explanation/Details: Once doors are replaced, they may require new casings.

DOORS GENERAL (EXTERIOR AND INTERIOR) - INSTALL EXTERIOR ENTRY DOOR ANTI-

PRY PLATE EA 1

Upgrade Explanation/Details: Back door had an attempted entry and needs a pry plate.

DOORS GENERAL (EXTERIOR AND INTERIOR) - REPAIR REAR EXIT STEEL DOOR AND

FRAME (TO OUTSIDE OF BLDG; FIRE RATED) NO HARDWARE EA 1

Upgrade Explanation/Details: If the door cannot be repaired, then replace

NAVY CARPET SCHEDULE

Manufacturer / Style:

Shaw / U.S. Navy Recruiting Standard: # 800G3

Color (Name, Number):

Water Garden, 69400

Product:

Carpet Tile

Installation Method:

Monolithic (See Note #1)

Installation Adhesive:

"LokDots" Adhesive System

Note 1: Carpet tile installation to be installed monolithic with all arrows pointing in the left-direction upon walking into the entrance of the space.

Note 2: If selected, for expedited delivery - government pricing contact: Shaw Contract for ALL inquiries go to website: www.shawcontract.com/usrecruiting. For pricing and order inquiries go to the pricing & ordering tab at the above website, or call: 1-800-356-7429 ext. 1 or email: cs.gsa@shawinc.com. For general inquiries call Michele Leise, 402-968-6025, email: michele.leise@shawcontract.com

Base Cove (for VCT & Carpet only): Johnsonite / Tarkett (https://distributor.tarkett.com), Rubber; Color: #40, Black, 4 H.

Flooring - General parameters: All floor areas will be of a common level, finished in a specified material and have a minimum live-load capacity of 50 pounds per square foot.

a. Porcelain Tiles: See ENCLOSURE. 8?.including.ordering.instructions, for a typical .oor tile pattern, including tile color / name, grout color / name, and tile transition designations. See speci.c Military Service Attachment for their requirement. 1. Common Hallway / Corridor / Security Closets and Restroom Areas: Porcelain tile with unpolished, non-slip surface shall be installed in the hallways, corridors, security closets, and restroom area .oors.

b. Chair Rail: Shall be installed on common area walls, excluding restrooms, and as referenced on the individual, Military Services finish schedule and approved floor plan / AE drawing. Chair rail to be mounted at bottom edge, 30 AFF, with semi-gloss paint finish. Profile to be Alexandria Molding:

AMH 300 1-1 / 16 x 3 , primed finger-jointed pine chair rail molding. See specific Military Services Attachments for their specific requirements. Note: Example of designated chair rail shown below:

Interior Signage: GS w/guidance: The Lessor shall order / install the Navy s Training Graphic and Honor, Courage, Commitment Graphic below. Graphics to be centered vertically between the ceiling and chair rail and horizontally scaled to 65% - 70% of the length of the wall. Each graphic is to be made as one-piece with the size of the graphic not to exceed 4 H x 18 L. COE representative to supply the Navy s wall graphic files. Lessor will coordinate with the COE on the installation of these self-adhesive, vinyl graphics or where applicable, rough-surface applications. Materials and instructions for installation are as follows:

a. Apply graphics to a flat smooth finish wall surface (after Navy paint is applied).

b. Allow paint a minimum of 7-10 days drying time before applying any wall graphics. Drying times will vary based on temperature and humidity.

c. Navy wall graphic shall be printed on and surface-applied to the self-adhesive vinyl. Printed Vinyl: 3M 180CV3-10 opaque white vinyl, surface ink jet printed with the Navy graphics. Surface laminated with 3M 8520 UV resistant matte clear overlay.

d. Alternate manufacturers (e.g., Arlon, Avery, GSP, OraCal, LG or other) sign vinyl materials equivalent to 3M 180 Series, rated for high bond wall application, and with minimum outdoor use 5-year warranty may be provided based on contractor recommendation.

e. Note 1: Wall mounted fixtures such as thermostats, wall switches, emergency lighting, and light sensors, etc., should be placed free and clear of all Military Service accents walls and graphics.

f. If selected, for expedited delivery-government pricing contact:

Manufacturer: Fastsigns, Inc.

POC: Chip Fullerton General Manager.

Phone: (901) 725-7446

Email: 81@fastsigns.com

Model: 3M 180CV3-10 Opaque White Vinyl wall covering

Substrate: Equal to 3M 180CV3-10 Opaque White Vinyl wall covering or better.

Installation: Utilize manufacturers recommended products in accordance with

3M 180CV3-10 Opaque White Vinyl wall covering installation instructions and surface preparation and adhesive guidelines. Clean the wall with a mixture of 70 percent isopropyl alcohol and 30 percent water. Do this two times. Cleaning with this mixture will increase adhesion on Low VOC paints.

Lessor to install the graphics according to manufacturer instructions in order to maintain their warranty requirements.

Graphics: a) Training Wall Graphic to be installed per approved floor plan / AE drawing:

A picture containing text, indoor, ceiling, airport

AI-generated content may be incorrect.

b) Honor, Courage, Commitment Wall Graphic to be installed per approved floor plan / AE drawing (opposite the Training Graphic):

A picture containing text, indoor, screenshot

AI-generated content may be incorrect.

Interior Doors: Shall be a flush panel solid core wood door with maple veneer and Grade 2 hardware or better.

1. Frames / Glass / Finish: i. Interior door and window frames to be Timely manufactured steel Classic S-Series (445) frames with factory applied Alumatone finish (not painted).

ii. Door color to be stained MinWax, Red Chestnut #232 (on all sides) with two (2) coats of polyurethane matte finish to be applied to stained areas.

iii. Doors requiring a full-length glass inset (low profile lite kit [24 x 60 ] with tempered glass), shall color match the Timely manufactured steel frames (factory applied Alumatone color SC108) or brushed stainless steel finish.

**USE THE APPLICABLE SPECIFICATION FOR THE TYPE OF DOOR BEING REPAIRED**

The following door opening hardware schedule and specifications shall apply:

Secondary Egress Doors: Steel doors and frames are required unless building aesthetics / standards only allow glass / other door types.

b. Interior Doors: Shall be a flush panel solid core wood door with maple veneer and Grade 2 hardware or better.

2. Frames / Glass / Finish: i. Interior door and window frames to be Timely manufactured steel Classic S-Series (445) frames with factory applied Alumatone finish (not painted).

ii. Door color to be stained MinWax, Red Chestnut #232 (on all sides) with two (2) coats of polyurethane matte finish to be applied to stained areas.

iii. Doors requiring a full length glass inset (low profile lite kit [24 x 60 ] with tempered glass), shall color match the Timely manufactured steel frames (factory applied Alumatone color SC108) or brushed stainless steel finish.

c. The following door opening hardware schedule and specifications shall apply: A Certified Integrator / Installer per manufacturer is required for extended warranty periods and trouble-free installations for Aiphone, Hanwha (Certified Video Professional / Wisenet Certified Professional (WCP)), ASSA ABLOY, and most other listed equipment manufacturers.

Door Openings (Doors / Hardware) Schedule & Specifications

EXTERIOR:

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Primary Entrance Door Single Aluminum:

N/A

Building Standard w/Glass Door

1- x 36 x 84

Match Building Standard

N/A

E1, E2

. Notes 1, 3 and 4

Primary Entrance Door Double Aluminum:

N/A

Building Standard w/Glass Door

1- x 36 x 84 (Ea)

Match Building Standard

N/A

E8

. Notes 1, 3 and 4

Secondary Egress Single Door(s):

N/A

Hollow Metal Core

1- x 36 x 84

See Paint Schedule

N/A

E3, E4

. Notes 1, 3 and 4

Secondary Egress Double Door(s):

N/A

Hollow Metal Core

1- x 36 x 84 (Ea)

See Paint Schedule

N/A

Similar to: E8, E9 or E10

. Notes 1, 3 and 4 Adjust as needed.

INTERIOR:

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Military entrance / egress, commander s office, conference / multi-purpose room, test / interview

N/A

Wood Door w-Full Length Glass Inset

1- x 36 x 80

See Notes

N/A

I1, I2, I3, I4, and I5, Notes 2, 3, and 4

General Door (service to internal common area, restroom, storage, janitorial, mechanical)

N/A

Wood Door

1- x 36 x 80

See Notes

N/A

I6, I8, I9, and I10

Notes 2, 3, and 4

Security Closet Door

N/A

Wood Door (Options):

Solid ~ Louvered Inset ~ Pocket Door

1- x 36 x 80

See Notes

N/A

I7a, I7b, and I7c

Notes 2, 3, and 4

HARDWARE SET DESCRIPTIONS:

EXTERIOR:

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Single Aluminum Exterior Door

8801EL36-24

Adams Rite - Rim Exit Device

2-5/8 x 36

Satin Aluminum

E1

55-56-PE8504F NEL (at stiles less than 4.5 )

55-56-PE8804F WEL (at stiles 4.5 or more)

Sargent Rim Exit Device with Motorized Latch Retraction

Nightlatch, key retracts latch.

Select model by verifying stile width.

36 wide

Other widths available.

Satin Stainless Steel

.PE80 for secondary egress w/ keypad

A620-626

Yale Cylinder Housing & Interchangeable Core (7-Pin)

N/A

Satin Chrome

MS4043-00-130

Adams Rite - Guard Ring

N/A

Clear Anodized

4612-1

Adams Rite - Power Transfer

N/A

Chrome

BF158-630

Rockwood - Door Pull

1 x 12

Satin SS

Match Existing building color

3531-689

Yale - Automatic Door Closer

2-1/8 x 12

Aluminum

BLP-210 (outswing)

DON-JO - Security Latch Guard (Anti-Pry Plate)

10 x 3.25 (outswing)

Match Existing

Conform to existing door configuration (e.g., offset, door handle, etc.)

DPS-M-GY

Securitron - Door Position Switch (Magnetic)

Gray

. Only required for shared / common area egress doors.

IXG-DM7-HIDA

Aiphone - IXG System Door-Entrance Station

13-11/16 H x 7-3/16 W x 2 D

SS

. (with mounting bracket)

SBX-IXGDM7

Aiphone - Surface Mount Box, Includes Rain Hood

13-3/4 H x 7-5/16 W x 3-1/16 D

SS

DK-26

Securitron - Keypad with CPU Board/Controller

1-1/2 W x 7 H x 7/8 D

SS

. Optional Rear Egress Only w/o Public Access

FPO250-C8D8E2

LSP - Power Supply

12 W x 14 H x 4.5 D

Black

. 8 Door / 8 Lock, 20A, 12VDC

(hardwired on security board)

Single Aluminum Exterior Door Emergency Egress ONLY. No door pull.

* - NOT the standard Secondary Egress.

PE8510F (at stiles less than 4.5 )

PE8810F (at stiles 4.5 or more)

Sargent Rim Exit Device

Exit only no outside trim or key override

Select model by verifying stile width.

36 wide

Other widths available.

Satin Stainless Steel

E2

If exterior inswing door consult with COE.

A620-626

Yale Cylinder Housing & Interchangeable Core

Satin Chrome

MS4043-00-130

Adams Rite - Guard Ring

N/A

Clear Anodized

3531-689

Yale - Automatic Door Closer

2-1/8 x 12

Aluminum

BLP-210 (outswing)

DON-JO - Security Latch Guard (Anti-Pry Plate)

10 x 3.25 (outswing)

Match Existing

Conform to existing door configuration (e.g., offset, door handle, etc.)

DPS-M-GY

Securitron - Door Position Switch (Magnetic)

Gray

. Only required for shared / common area egress doors.

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Single Hollow Metal/Wood Exterior Door

8701EL36-24

Adams Rite - Rim Exit Device

2-5/8 x 36

Satin Aluminum

E3

. 3701-36 for fire rated doors

55-56-PE8504F NEL (at stiles less than 4.5 )

55-56-PE8804F WEL (at stiles 4.5 or more)

Sargent Rim Exit Device with Motorized Latch Retraction

Nightlatch, key retracts latch.

Include shim kits as needed for glass moldings.

Select model by verifying stile width.

36 wide

Other widths available.

Satin Stainless Steel

.PE80 for secondary egress w/ keypad

A620-626

Yale Cylinder Housing & Interchangeable Core

N/A

Satin Chrome

MS4043-00-130

Adams Rite - Guard Ring

N/A

Clear Anodized

4612-1

Adams Rite - Power Transfer

N/A

Chrome

BF158-630

Rockwood - Door Pull

1 x 12

Satin SS

Match Existing building color

3531-689

Yale - Automatic Door Closer

2-1/8 x 12

Aluminum

BLP-210 (outswing)

DON-JO - Security Latch Guard (Anti-Pry Plate)

10 x 3.25 (outswing)

Match Existing

Conform to existing door configuration (e.g., offset, door handle, etc.)

DD01-180ULSN

NuK3y - Peephole (220 Viewing Angle)

1-1/16 x

1-3/8 ~ 2-1/4

Satin Nickel Gray

9/16 Hole

Install height @

5'-0" AFF

IXG-DM7-HIDA

Aiphone - IXG System Door-Entrance Station

13-11/16 H x 7-3/16 W x 2 D

SS 1

. (with mounting bracket)

SBX-IXGDM7

Aiphone - Surface Mount Box, Includes Rain Hood

13-3/4 H x 7-5/16 W x 3-1/16 D

SS

DK-26

Securitron - Keypad with CPU Board/Controller

1-1/2 W x 7 H x 7/8 D

SS

. Optional Rear Egress Only w/o Public Access

FPO250-C8D8E2

LSP - Power Supply (hardwired on security board)

12 W x 14 H x 4.5 D

Black

. 8 Door / 8 Lock, 20A, 12VDC

Single Hollow Metal/Wood Exterior Door Emergency Egress ONLY. No door pull.

* - NOT the standard Secondary Egress.

PE8510F (at stiles less than 4.5 )

PE8810F (at stiles 4.5 or more)

Sargent Rim Exit Device

Exit only no outside trim or key override.

Include shim kits as needed for glass moldings.

Select model by verifying stile width.

36 wide

Other widths available

Satin Aluminum

E4

A620-626

Yale Cylinder Housing & Interchangeable Core

N/A

Satin Chrome

MS4043-00-130

Adams Rite - Guard Ring

N/A

Clear Anodized

3531-689

Yale - Automatic Door Closer

2-1/8 x 12

Aluminum

DD01-180ULSN

NuK3y - Peephole (220 Viewing Angle)

1-1/16 x

1-3/8 ~ 2-1/4

Satin Nickel

9/16 Hole

Install height @

5'-0" AFF

BLP-210 (outswing)

DON-JO - Security Latch Guard (Anti-Pry Plate)

10 x 3.25 (outswing)

Match Existing

Conform to existing door configuration (e.g., offset, door handle, etc.)

DPS-M-GY

Securitron - Door Position Switch METAL (Magnetic)

Gray

. DPS-W-GY for Wood Doors Only required for shared / common area egress doors.

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Double Aluminum Exterior Door (both active leaf s, one electrified)

8801EL36-24

Adams Rite - Rim Exit Device

2-5/8 x 36

Satin Aluminum

E8 . Optional Rear

8801-36

Adams Rite - Rim Exit Device

2-5/8 x 36

Satin Aluminum

55-56-PE8504F NEL x PE8510F x L980A mullion (at stiles less than 4.5 )

55-56-PE8804F WEL x PE8810F x L980S mullion (at stiles 4.5 or more)

Sargent Pair of Rim Exit Device with Motorized Latch Retraction one leaf.

Nightlatch, key retracts latch at active leaf. Exit only inactive. Keyed removable mullion.

Select model by verifying stile width.

36 wide

Other widths available

Satin Stainless Steel

.PE80 for secondary egress w/ keypad

A620-626

Yale Cylinder Housing & Interchangeable Core

N/A

Satin Chrome

4612-1

Adams Rite - Power Transfer

N/A

Chrome

BF158-630

Rockwood - Door Pull

1 x 12

Satin SS

On electrified door. Match Existing building color

3531-689

Yale - Automatic Door Closer

2-1/8 x 12

Aluminum

MS4043-00-130

Adams Rite - Guard Ring

N/A

Clear Anodized

3890-10-628

Adams Rite Removable Mullion for 8800 Series Exit Devices

N/A

Clear Anodized

DPS-M-GY

Securitron - Door Position Switch (Magnetic)

Gray

. Only required for shared / common area egress doors.

IXG-DM7-HIDA

Aiphone - IXG System Door-Entrance Station

13-11/16 H x 7-3/16 W x 2 D

SS

. (with mounting bracket)

SBX-IXGDM7

Aiphone - Surface Mount Box, Includes Rain Hood

13-3/4 H x 7-5/16 W x 3-1/16 D

SS SS

DK-26

Securitron - Keypad with CPU Board/Controller

1-1/2 W x 7 H x 7/8 D

FPO250-C8D8E2

LSP - Power Supply (hardwired on security board)

12 W x 14 H x 4.5 D

Black

. 8 Door / 8 Lock, 20A, 12VDC

INTERIOR:

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Service Interior Entrance Doors (w/in Gov t controlled leased premises):

Varies

Solid Core Flush Wood Door & Full Length Glass Inset

1- x 36 x 80

See Notes

Ea

I1

Notes 2, 3 and 4

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

N/A

Satin Chrome

K1050-CSK-630

Rockwood Kick Plate

Satin SS

Riviera-G8-034

Hunter Douglas Riviera Commercial Aluminum Horizontal Blinds (cordless)

Brushed Aluminum

Note 2

Service Interior Secondary Egress Door (w/in Gov t controlled leased premises) if applicable:

Varies

Solid Core Flush Wood Door

1- x 36 x 80

See Notes

Ea

I2

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

Satin Chrome

K1050-CSK-630

Rockwood Kick Plate

Satin SS

DD01-180ULSN

NuK3y - Peephole (220 Viewing Angle)

1-1/16 x

1-3/8 ~ 2-1/4

Satin Nickel

9/16 Hole

Install height @

5'-0" AFF

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Station Commander Office Door(s):

Varies

Solid Core Flush Wood Door & Full Length Glass Inset

1- x 36 x 80

See Notes

Ea

I3

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

N/A

Satin Chrome

Test & Interview Room Door:

Varies

Solid Core Flush Wood Door & Full Length Glass Inset

1- x 36 x 80

See Notes

Ea

I4

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

B-TB-4601LN-626

Yale Passage Latch

N/A

Satin Chrome

B-UB-4601LN-626 if local code requires return

Multipurpose / Conference Room

Door(s) if applicable:

Varies

Solid Core Flush Wood Door

1- x 36 x 80

See Notes

Ea

I5

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

N/A

Satin Chrome

Storage Room Door:

Varies

Solid Core Flush Wood Door

1- x 36 x 80

See Notes

Ea

I6

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

N/A

Satin Chrome

Security Closet Door (Standard):

Varies

Solid Core Flush Wood Door

1- x 36 x 80

See Notes

Ea

I7a

Standard Door

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

Application:

Model / Skew # s:

Description:

Size:

Finish:

Qty:

Set Codes:

Notes:

Security Closet Door (Full Louvered Inset):

Varies

Solid Core Flush Wood Door & Full Length Louvered Inset

1- x 36 x 80

See Notes

Ea

I7b

Louvered Door (Option)

Classic S-Series(Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

N/A

Satin Chrome

2701 R/PA- 689

Yale - Automatic Door Closer

2-1/8 x 12

Aluminum

Security Closet Door (Pocket):

Varies

Solid Core Flush Wood POCKET Door

1- x 36 x 80

See Notes

Ea

I7c

Required for Air Force HUB Offices

PF28200A7280

Pemko - Pocket Door Hardware

N/A

N/A

2 x 4 Framing, With soft close / open

PF134KIT

Pemko - Pocket Door

Frame Kit

1- x 36 x 80

Chrome Plated

Ea

Kit for 1-3/4 doors within 2 x 4 Framing

P-Series TA-23

Timely Pocket Trim Kit

N/A

Alumatone

XGT-243- PD9653A-S7-32D-RH or LH-TT07

Inox PD96 Series Sliding, Self-Latching/Locking Mortise Entry Lock

N/A

Satin SS

Specify handing in order as RH or LH. If local code requires door handle return use XGT-244.

A600-626

Yale Interchangeable Core (7-Pin)

N/A

Chrome

N/A

Plywood Reinforcement

N/A

N/A

Ea plywood installed between pocket door studs for rigidity

Restroom Door(s):

Varies

Solid Core Flush Wood Door

1- x 36 x 80

See Notes

I8

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4602LN-626

Yale Privacy / Bath Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4602LN-626 if local code requires return

K1050-CSK-630

Rockwood Kick Plate

Satin SS

Janitorial Closet Door:

Varies

Solid Core Flush Wood Door

1- x 36 x 80

See Notes

Ea

I9

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

N/A

Satin Chrome

K1050-CSK-630

Rockwood Kick Plate

Satin SS

Mechanical Room Door(s) - if applicable

Varies

Solid Core Flush Wood Door

1- x 36 x 80

See Notes

Ea

I10

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36 x 80

Alumatone

Ea

Door & window frames to match

TA2714-USA-US26D

McKinney - Hinges

4-1/2 x 4-1/2

Satin Chrome

B-TB-4607LN-626

Yale Entry Lever Cylinder Lockset

N/A

Satin Chrome

B-UB-4607LN-626 if local code requires return

A600-626

Yale SFIC Core (7-Pin)

N/A

Satin Chrome

NOTES & ADDITIONAL REQUIREMENTS FOR EXTERIOR & INTERIOR DOORS &

HARDWARE:

1) Exterior Egress Doors: a. Lessor Shell Requirements / Exterior Door Health Survey: Exterior door openings to the Government controlled space shall be surveyed to ensure a healthy, weather tight and fully functional door unit (door, frame, glass, and hardware). Door opening / swing to be outswing only, fail secure with Grade 1 hardware and no mail slots allowed. Existing mail slots in exterior doors shall be removed. Survey / coordinate hardware requirements on existing doors / frames to be re-used. Clean, repair or replace as necessary - advise COE representative if existing door / hardware needs to be replaced.

b. Door release time range: Default of 5-10 seconds for all electrified doors / key pads (IXG, DK- 26).

c. Hinge pins for exterior doors to be concealed / non-removable (existing to remain if meets requirements).

d. DON-JO Door Strengtheners: www.don-jo.com (door / hardware specific as needed for long term proper door usage (connectivity of video intercom entry control (EC) system components), As determined by EC system contractor (e.g. - wrap around plate; inactive door wrap around strike prep; hinge side wrap around reinforcement; mortise lock wrap around; door reinforcer [deadbolts & key-in-knob locks]).

e. See paragraph G.9.ii: Hunter Douglas Fixed Panel Shade (absolutely no mini-blinds on exterior doors).

f. See paragraph G.6. & G.7: 3M Fragment Retention Film (required for ALL glass in doors and windows on the perimeter of Government controlled leased premises).

g. Additional door types (non-standard / double doors / all glass Herculite doors) confirm with COE (located in Appendix C).

2) Interior Doors:

a. To be flush panel solid core wood door, maple veneer, stained with MinWax Red Chestnut #232 (all sides); with two (2) coats of polyurethane matte finish applied to stained areas.

b. Metal Frames (for doors & windows): Interior door and window frames to be Timely manufactured steel frames with factory applied Alumatone aluminum / silver finish (not painted).

For doors with a full length tempered glass inset (24 x 60 ), finish to match the Timely frames Alumatone aluminum / silver finish metal frame. See paragraph G.6. & G.7 for full details.

c. Grade 2 hardware or better required. Specifications are for no return handles. If required by local code, door handles with a return may be substituted.

d. Doors to include a Rockwood (403-626 satin chrome) convex rubber doorstop/bumper.

e. Security Closet ONLY Options: 1. Flush panel wood finished door.

2. Flush panel wood finished door with full length louvered inset if increased Security Closet ventilation is required.

3. Flush panel wood finished pocket door may be installed to minimize space requirements (no swing taking up space).

f. Mini-Blinds: Interior doors & windows to have mini-blinds, except for Test / Interview rooms. Must be secured at the bottom of doors with metal clips.

3) Certified Integrators / Installers (warranty):

a. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha

b. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/

c. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators

4) Keying or Re-Keying: Before.delivery.and.acceptance.of.the.premises?.all.previous.existing.

exterior.door=locks.shall.be.re=keyed. The Lessor will be responsible for coordinating with the COE on the number of new keys required to be furnished to each Military Service. EACH individual Military Service office shall be separately keyed. Note: Both front and rear exterior exit doors for each Military Service should be same-keyed. Keys to be minimized / same-keyed for each Military Services primary and secondary egress doors, interior common area doors, security closet and each Military Service specific interior doors (excluding Station Commanders Offices). Station Commanders Offices shall be separately keyed. If fire department Knox Box is required, a key must be provided. See also paragraph A.4 regarding the number of recruiters needing keys.

5) Acronym Legend: a. SS = Stainless Steel b. EA = Each c. . = Electrified component.

*** END OF NARRATIVE ***

Requirements FY26 facility upgrades for various Joint Recruiting Facilities

Section F - Deliveries or Performance

0001 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026

1 JobQuantity

Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA

W2SD ENDIST NEW YORK

KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY

10278-0004 UNITED STATES

0002 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026

1 JobQuantity

Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA

W2SD ENDIST NEW YORK

KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY

10278-0004 UNITED STATES

0003 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026

1 JobQuantity

Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA

W2SD ENDIST NEW YORK

KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY

10278-0004 UNITED STATES

0004 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026

1 JobQuantity

Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA

W2SD ENDIST NEW YORK

KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY

10278-0004 UNITED STATES

0005 Delivery Schedule Delivery Before Delivery Date 30 Nov 2026

1 JobQuantity

Address and POC Place of Performance DoDAAC: W912DS CountryCode: USA

W2SD ENDIST NEW YORK

KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300 NEW YORK, NY

10278-0004 UNITED STATES

Section G - Contract Administration Data

DFARS Clauses Incorporated by Reference

Number Title Effective Date

Alternate Deviation

Variation Effective Date

252.201-7000 Contracting Officer's Representative.

1991-12

252.232-7003 Electronic Submission of Payment Requests and Receiving Reports.

2018-12

Section H - Special Contract Requirements

"General Decision Number: NY20260002 05/18/2026

State: New York

Construction Types: Building, Heavy and Highway

Counties: New York Counties of

Albany, Columbia, Fulton, Greene, Montgomery, Rensselaer, Saratoga, Schenectady, Schoharie and Washington

Excludes Building Construction in COLUMBIA, FULTON, GREENE & MONTGOMERY Counties

Modification Number Publication Date

1 01/30/2026

2 05/18/2026

ASBE0040-002 05/01/2025

Rates Fringes

HAZARDOUS MATERIAL HANDLER (DUTIES LIMITED TO

PREPARATION WETTING; STRIPPING; REMOVAL; SCRAPPING;

VACUUMING; BAGGING; AND DISPOSING OF ALL INSULATION

MATERIALS, WHETHER THEY CONTAIN ASBESTOS OR NOT

FROM MECHANCIAL SYSTEMS)............................$ 41.74 27.58

ASBESTOS/INSULATOR WORKER (SCOPE OF WORK: INCLUDES

APPLICATION OF ALL INSULATING MATERIALS,

PROTECTIVE, COVERINGS, COATING AND FINISHING TO

ALL TYPES OF MECHANICAL SYSTEMS.)...................$ 41.74 27.58

BOIL0197-002 01/01/2025

Rates Fringes

BOILERMAKER.........................................$ 43.34 27.66

BRNY0002-019 12/03/2025

Rates Fringes

BRICKLAYER (BRICKLAYERS, STONE MASONS, CEMENT

MASONS, PLASTERERS, POINTERS, CAULKERS & CLEANERS)..$ 41.79 22.33

CARP0279-006 07/01/2025

Rates Fringes

CARPENTERS: CARPENTERS, MILLWRIGHTS, PILE DRIVERS

(HEAVY AND HIGHWAY CONSTRUCTION (COLUMBIA AND

GREENE COUNTIES))...................................$ 44.72 31.23

CARP0291-005 07/01/2025

Rates Fringes

CARPENTERS: (WASHINGTON COUNTY BUILDING)...........$ 36.38 24.65

CARPENTERS: (SARATOGA COUNTY BUILDING).............$ 36.38 24.65

CARP0291-008 07/01/2025

Rates Fringes

CARPENTERS: HEAVY & HIGHWAY CONSTRUCTION (ALBANY,

FULTON, MONTGOMERY, RENSSELAER, SCHENECTADY AND

SCHOHARIE COUNTIES).................................$ 44.28 24.50

CARPENTERS & SOFT FLOOR LAYERS: BUILDING

CONSTRUCTION (EXCLUDING MONTGOMERY COUNTY) (ALBANY,

FULTON, MONTGOMERY, RENSSELAER, SCHENECTADY AND

SCHOHARIE COUNTIES).................................$ 36.38 24.65

CARP0291-010 07/01/2024

Rates Fringes

CARPENTERS: DIVERS..................................$ 69.28 24.50

CARPENTERS: (DIVERS (DRY DAY))......................$ 45.28 24.50

CARPENTERS: (CARPENTERS)............................$ 44.28 24.50

ELEC0236-001 06/01/2024

Rates Fringes

ELECTRICIAN (ALBANY; COLUMBIA; FULTON; GREENE (THAT

PORTION NORTH OF A LINE FOLLOWING THE SOUTH LIMITS

OF THE CITY OF CATSKILL); MONTGOMERY; RENSSELAER,

SARATOGA; SCHENECTADY; SCHOHARIE; WASHINGTON).......$ 48.00 32.09

ELEC0363-004 04/01/2024

Rates Fringes

ELECTRICIAN (GREENE COUNTY (PORTION OF)) FOOTNOTE:

A. PAID HOLIDAYS: NEW YEAR'S DAY, PRESIDENT'S

DAY, MEMORIAL DAY, FOURTH OF JULY, LABOR DAY,

PRESIDENTIAL ELECTION DAY, VETERAN'S DAY,

THANKSGIVING DAY, DAY AFTER THANKSGIVING, CHRISTMAS

DAY.................................................$ 46.50 40.57

ELEC1249-003 05/05/2025

Rates Fringes

ELECTRICIAN LINE CONSTRUCTION: LIGHTING AND TRAFFIC

SIGNAL INCLUDING ANY AND ALL FIBER OPTIC CABLE

NECESSARY FOR TRAFFIC SIGNAL SYSTEMS, TRAFFIC

MONITORING SYSTEMS AND ROAD WEATHER INFORMATION

SYSTEMS MECHANIC FOOTNOTE: A. NEW YEAR'S DAY,

MEMORIAL DAY, INDEPENDENCE DAY, LABOR DAY,

THANKSGIVING DAY, CHRISTMAS DAY, PLUS PRESIDENT'S

DAY, GOOD FRIDAY, DECORATION DAY, ELECTION DAY FOR

THE PRESIDENT OF THE UNITED STATES AND ELECTION DAY

FOR THE GOVERNOR OF THE STATE OF NEW YORK, PROVIDED

THE EMPLOYEE WORKS THE DAY BEFORE OR THE DAY AFTER

THE HOLIDAY.........................................$ 42.29 30.66

ELECTRICIAN LINE CONSTRUCTION: LIGHTING AND TRAFFIC

SIGNAL INCLUDING ANY AND ALL FIBER OPTIC CABLE

NECESSARY FOR TRAFFIC SIGNAL SYSTEMS, TRAFFIC

MONITORING SYSTEMS AND ROAD WEATHER INFORMATION

SYSTEMS LINEMAN & TECHNICIAN FOOTNOTE: A. NEW

YEAR'S DAY, MEMORIAL DAY, INDEPENDENCE DAY, LABOR

DAY, THANKSGIVING DAY, CHRISTMAS DAY, PLUS

PRESIDENT'S DAY, GOOD FRIDAY, DECORATION DAY,

ELECTION DAY FOR THE PRESIDENT OF THE UNITED STATES

AND ELECTION DAY FOR THE GOVERNOR OF THE STATE OF

NEW YORK, PROVIDED THE EMPLOYEE WORKS THE DAY

BEFORE OR THE DAY AFTER THE HOLIDAY.................$ 52.86 35.60

ELECTRICIAN LINE CONSTRUCTION: LIGHTING AND TRAFFIC

SIGNAL INCLUDING ANY AND ALL FIBER OPTIC CABLE

NECESSARY FOR TRAFFIC SIGNAL SYSTEMS, TRAFFIC

MONITORING SYSTEMS AND ROAD WEATHER INFORMATION

SYSTEMS GROUNDMAN…

This is the start of the file's text. The full file is on GovTribe.