Text version

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Building 4427

JACOBS

1100 N. Glebe Road, Suite 500

Arlington, VA 22201

Architect-Engineering Services in Support of the FY18 Aircraft Apron, Taxiway & Support Facilities Contract

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

Contract F8Z95503-S17-0001

July 27, 2017 Page 1

Contents

1.0 EXECUTIVE SUMMARY

2.0 ACRONYMS

3.0 INTRODUCTION

4.0 ASBESTOS INSPECTION REPORT

4.1 SURVEY METHODOLOGY

4.1.1 LABORATORY ANALYSES

4.1.2 INACCESSIBLE AND LIMITED-ACCESS SPACES

4.1.3 SURVEY LIMITATIONS

4.2 ASBESTOS INSPECTION RESULTS

4.3 ASBESTOS CONCLUSIONS

5.0 LEAD-BASED PAINT (LBP) INSPECTION REPORT

5.1 LBP INSPECTION REPORT

5.2 LBP INSPECTION DATA

5.3 LBP INSPECTION RESULTS

5.4 LBP ABATEMENT REQUIREMENTS

6.0 POLYCHLORINATED BIPHENYLS (PCBS)

7.0 UNIVERSAL WASTES AND OZONE-DEPLETING SUBSTANCES

8.0 DISCLAIMER

Attachment 1 – Asbestos Results

Attachment 2 – ACM Photos

Attachment 3 – LBP Results

Attachment 4 – LBP Photos

Attachment 5 – PCB Results

Attachment 6 – Drawings

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 2

1.0 EXECUTIVE SUMMARY

The Naval Facilities Engineering Command (NAVFAC) retained Jacobs Engineering Group, Inc. (Jacobs) to provide Architect-Engineering Services for the Joint Base McGuire-Dix-Lakehurst (JB MDL) (Facility) Demolition of Building 4427. Jacobs retained Global, Inc. (GLOBAL) to perform the environmental services associated with the project. This report documents the inspection of the facility by several specialized inspectors for Asbestos-Containing Material (ACM), Lead-Based Paint (LBP), Polychlorinated Biphenyls (PCBs), and other potentially hazardous materials.

Asbestos:

GLOBAL’s EPA-accredited, Maryland-licensed Asbestos Hazard Emergency Response Act (AHERA) Inspectors assessed the Facility for the presence of asbestos-containing materials (ACM) on July 6,2017. All areas of the facility were made accessible for inspection.

The following building material was identified as ACM by Polarized Light Microscopy

(PLM):

• Beige Floor Tile (unknown size)

Several materials should be assumed asbestos-containing based on the age of the structure and/or out of concern that sampling may compromise the integrity of the material.

The following building materials were not sampled due to sampling limitations, and should be assumed to be ACM:

1. Fire Door

2. Black and Brown Fibrous Paneling within the Attic Space

3. Roofing materials (membranes, patching, sealants, etc.)

Lead-Based Paint:

GLOBAL’s Industrial Hygienists (IHs) assessed the Facility for the presence of Lead- Based Paint (LBP) materials on July 6, 2017, using a NITON XLp XRF-type Analyzer (serial number 18595). All areas of the facility were made accessible for inspection. Most tested components were found to be below the standard that indicates a material as containing LBP.

The following components were determined to contain LBP:

1. White paint under roof on exterior of the building behind the soffit

2. Yellow/White exterior window lintels

3. White paint on concrete block in the radio room

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 3

4. Any unnoted paint(s) found inside the ceiling plenum, under wall paper, or under the roof, fascia, or soffit, found during demolition should be assumed to contain lead paint until sampling determines otherwise.

When these ACM or LBP materials are disturbed during renovation/demolition, they are to be managed in accordance with applicable Federal, state, and local regulations.

Polychlorinated Biphenyls (PCBs)

None of the materials tested positive for PCBs at the time of the inspection. There is low possibility that some PCB containing light ballasts exist in the facility. Should Fluorescent light ballasts that are not specifically marked Non-PCB containing ballasts be encountered during renovation, they should be managed and disposed of in accordance with Toxic Substances Control Act (TSCA) Storage and Disposal Requirements for Fluorescent Light Ballasts.

Universal Wastes and Ozone-Depleting Substances

Fluorescent lightbulbs are potentially mercury-containing light bulbs. Global did not identify any fluorescent lightbulbs at the time of the survey. Should any stored fluorescent bulbs be found on the site, they should be considered waste. Disposal and management of spent bulbs are regulated by the Recreation Conservation and Recovery Act (RCRA) Universal Waste Rule (UWR), and should be handed and disposed of in accordance with this rule.

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 4

2.0 ACRONYMS

ACM Asbestos-Containing Material

AHERA Asbestos Hazard Emergency Response Act

DOCA Department of Community Affairs

EPA Environmental Protection Agency

FT Floor Tile

HEPA High Efficiency Particulate Air

IH Industrial Hygienist

LBP Lead-Based Paint

NIOSH National Institute of Occupational Safety and Health

NESHAP National Emission Standards for Hazardous Air Pollutants

OSHA Occupational Safety & Health Administration

PCM Phase Contrast Microscopy

PI Pipe Insulation

PLM Polarized Light Microscopy

PCB Polychlorinated Biphenyl

PACM Presumed Asbestos-Containing Material

RACM Regulated Asbestos-Containing Material

RCRA Resource Conservation and Recovery Act (RCRA)

SDS Safety Data Sheet

TEM Transmission Electron Microscopy

TSI Thermal System Insulation

UW Universal Waste

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 5

3.0 INTRODUCTION

The Naval Facilities Engineering Command (NAVFAC) retained Jacobs Engineering Group, Inc. (Jacobs) to provide Architect-Engineering Services for the Joint Base McGuire-Dix-Lakehurst (JB MDL) (Facility) Demolition of Building 4427. Jacobs retained Global, Inc. (GLOBAL) to perform the environmental services associated with the project. This report documents the inspection of the facility by several specialized inspectors for Asbestos-Containing Material (ACM), Lead-Based Paint (LBP), Polychlorinated Biphenyls (PCBs), and other potentially hazardous materials. The mutual goal of the contractor and the government is to achieve a quality product, safely, within the expected timeframe and budget.

4.0 ASBESTOS INSPECTION REPORT

GLOBAL inspected certain areas of Building 4427 for the presence of potential ACBM on July 6, 2017. The results of these inspections are presented in Table 2 and have been updated on the drawings at end of the report. The Environmental Protection Agency (EPA) regulates how persons work with asbestos and regulates those who train persons to work with asbestos. The EPA regulations cover four asbestos activities; (1) removal, repair, or encapsulation of asbestos-containing materials (ACM), (2) approval of asbestos training providers, (3) regulation of persons accredited to perform asbestos-related activities, and (4) asbestos in schools. The EPA regulates the enforcement of the National Emission Standards for Hazardous Air Pollutants (NESHAP), and enforcement of the asbestos notification regulations.

4.1 SURVEY METHODOLOGY

The asbestos survey was divided into two distinct phases: pre-inspection planning and inspection for ACM. The pre-inspection planning phase includes reviewing previous inspection reports, management plans, and abatement reports, if available. Jacobs provided GLOBAL with information regarding the planned use of the property. GLOBAL planned an inspection strategy, and scheduled the inspection work. It was determined that this survey should include select portions of the building to ensure that intended renovation, and/or related demolition, can be conducted in an efficient and safe manner compliant with applicable Federal, state, and local regulations.

The reinspection was conducted on an area-by-area basis as determined in the planning phase. GLOBAL’S EPA-accredited Asbestos Hazard Emergency Response Act (AHERA) Inspectors identified materials considered to be suspect ACM according to AHERA protocols, unless otherwise specified. While AHERA is not required for this facility, it is considered the most stringent standard.

As defined by AHERA, suspect materials include the following building material types:

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 6

Surfacing materials - including spray-applied or troweled-on wall/ceiling coatings

Thermal System Insulation (TSI) - including pipe insulation, boiler lagging, tank insulation, and duct insulation

Miscellaneous materials - including ceiling tiles, floor tiles/mastic, gaskets (if accessible), fire doors, wallboard/spackle, roofing systems, etc.

Suspect materials that were homogeneous in nature (i.e., uniform in color and texture, installation date) were identified, touched to determine friability, and sampled by removing a small piece. Each small sample was placed into a labeled container. The sample location was promptly patched and repaired. One or more samples were collected from each homogeneous material if it was deemed safe to do so by the inspector. Samples were collected in a randomly-distributed manner in accordance with AHERA provisions (40 CFR 763.86). The location, condition, and quantity of each homogeneous material were recorded in the inspector’s log.

Extreme care was taken to avoid potential fiber release during the inspection/sampling process. Before sample collection, a fine mist of water was typically applied to the sample site. Samples were collected using sharpened core samplers and/or razor knives, where necessary, and immediately placed in labeled containers and sealed. Any dust generated was wet-wiped and/or dust suppressant was applied to minimize the potential for fiber release.

4.1.1 LABORATORY ANALYSES

The samples of suspect ACMs were packaged and delivered under strict chain of custody procedures. The samples were analyzed by EMSL Analytical, Inc. of Beltsville, MD, a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory.

Quantification of asbestos content in bulk samples was performed via EPA 600/R- 93/116 Method using Polarized Light Microscopy (PLM). Personnel performing analyses have been trained in identifying asbestos by the McCrone Research Institute and participate in national accreditation programs. Laboratory data sheets indicating the sample designations, gross descriptions, and analytical results are provided at the end of this section. The Occupational Health and Safety Administration (OSHA) defines an ACM as any material containing greater than 1% asbestos.

Laboratory results may be found in Attachment 1. Photos of positively-identified ACM may be found in Attachment 2.

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 7

4.1.2 INACCESSIBLE AND LIMITED-ACCESS SPACES

Every reasonable attempt was made to locate ACM present, and identify ACM as TSI, surfacing material, or “other” miscellaneous materials in the areas surveyed.

Inaccessible areas could be addressed only through extrapolation of conditions in accessible building spaces. Areas that were inaccessible, or where the survey was limited to visual observation only, are identified in this report’s narrative. Such inaccessible areas might include, but are not limited to the those listed in Table 1:

Description of Inaccessible Locations.

Table 1: Description of Inaccessible Locations

Within walls Within fire doors

Enclosed pipe/duct chases Inside mechanical equipment/ductwork

Above solid ceilings Beneath materials stored in the building

Confined Spaces Areas above a standard six-foot ladder’s reach (within Attic space)

Limited access areas (i.e. beneath fixed walls, under wall-to-wall carpeting, or above fixed ceilings with small access hatches) were investigated as feasible, and, as a result, conclusions regarding the presence or absence of asbestos might be of limited accuracy.

4.1.3 SURVEY LIMITATIONS

All other suspect materials uncovered during renovation/demolition activities not identified within this report should be assumed asbestos-containing, until bulk sampling and laboratory analysis confirm otherwise.

In a few instances, GLOBAL’s inspector identified a layer of floor tile beneath strongly-adhered carpeting. It was not possible to definitively state the boundaries of the layer of floor tile and associated mastic. When these layers of beige floor tile are encountered, the floor tile and associated mastic should be assumed asbestos-containing, until additional bulk sampling and laboratory analysis confirm otherwise. Furthermore, it was not possible to account for the integrity of the floor tile. Should floor tile break (and, therefore, be rendered “friable” during carpet removal, the carpet should be considered an ACM as well.

To protect the integrity and safety of the component, the fire door was not sampled by GLOBAL’s inspector. The brown and black, fibrous paneling within the attic space was not sampled due to height of installation. Except for one sample of roofing shingle, the roofing materials were not sampled. These materials should be considered presumed asbestos containing materials (PACM).

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 8

GLOBAL does not take responsibility for any missing and/or incomplete data, and/or reports that were not provided prior to and/or during this survey.

4.2 ASBESTOS INSPECTION RESULTS

Asbestos sampling was performed on July 6, 2017 by GLOBAL’s Industrial Hygienists (IHs), and EPA-accredited AHERA Inspectors. Areas identified by base personnel were inspected for the presence of ACM.

A total of 68 asbestos samples were collected from 38 homogeneous materials. Results of analysis are noted in Table 2: Description of Homogeneous Areas and Sampling Results.

Table 2: Description of Homogeneous Areas and Sampling Results

Sample # Description Sampling Location ACBM?

MCG-4427-070617

B/1, B/2

Cream stucco surfacing material Exterior walls ND

MCG-4427-070617

B/3, B/4 Gray shingle and black tar Roof ND

MCG-4427-070617

B/5, B/6, B/45 Gray window caulk (hard) Exterior windows ND

MCG-4427-070617

B/7, B/8 Gray gutter seam sealant Exterior along roof ND

MCG-4427-070617

B/9, B/10 (FT)

12"x12" floor tile light cream with gray speckles Women's Restroom ND

MCG-4427-070617

B/9, B/10 (M)

Yellow mastic associated with 12"x12" floor tile light cream with gray speckles (above)

Women's Restroom ND

MCG-4427-070617

B/11, B/12 (CB) Black baseboard Women's Restroom ND

MCG-4427-070617

B/11, B/12 (M)

Tan mastic under black baseboard (above) Women's Restroom ND

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 9

MCG-4427-070617

B/13, B/14 (FT)

12"x12" floor tile dark gray floor tile Mechanical Room ND

MCG-4427-070617

B/13, B/14 (M)

Yellow mastic associated with 12"x12" floor tile dark gray floor tile (above)

Mechanical Room ND

MCG-4427-070617

B/15, B/16

Drywall-white with brown paper Mechanical Room ND

MCG-4427-070617

B/17 (CB) Brown baseboard Mechanical Room ND

MCG-4427-070617

B/17 (M)

Yellow mastic on B/17 (above) Mechanical Room ND

MCG-4427-070617

B/18 White joint compound Mechanical Room ND

MCG-4427-070617

B/19, B/20 White flue insulation Mechanical Room ND

MCG-4427-070617

B/21, B/22 (FT) 12"x12" bright blue floor tile Men's Restroom ND

MCG-4427-070617

B/21, B/22 (M)

Yellow mastic on 12"x12" bright blue floor tile (above) Men's Restroom ND

MCG-4427-070617

B/23, B/24 (CB) Dark blue baseboard Men's Restroom ND

MCG-4427-070617

B/23, B/24 (M)

Gray mastic on dark blue baseboard (above) Men's Restroom ND

MCG-4427-070617

B/25, B/33

2'x2' White ceiling tile -medium sized worm and pinholes

Found throughout the building ND

MCG-4427-070617

B/26, B/27

Carpet mastic and misc.

floor mastics

Lounge under carpet-throughout ND

MCG-4427-070617

B/28, B/40 (FT)

12"x12" medium gray mottled floor tile

Elect/Phone Room (rear); small radio equipment closet ND

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 10

MCG-4427-070617

B/28, B/40 (M)

Tan mastic under 12"x12" medium gray mottled floor tile (above)

Elect/Phone Room (rear); small radio equipment closet ND

MCG-4427-070617

B/29 (FT)

Remnants of 12"x12" beige with tan speckles floor tile

Along threshold into Elect/Phone Room (rear); and under office door frames throughout

ND

MCG-4427-070617

B/29 (M)

Black and yellow mastic on 12"x12" beige with tan speckles floor tile (above)

Along threshold into Elect/Phone Room (rear); and under office door frames throughout

ND

MCG-4427-070617

B/30 Red fire stop Elect/Phone Room (front) ND

MCG-4427-070617

B/31

Drywall-white with brown paper Elect/Phone Room (front) ND

MCG-4427-070617

B/32

White floor leveling compound Threshold at office door ND

MCG-4427-070617

B/32 (M)

Tan carpet mastic on white floor leveling compound (above)

Threshold at office door ND

MCG-4427-070617

B/34, B/35 (FT)

Unknown sized beige floor tile

Under dark gray carpet squares in ramp to outside

5% Chrysotile

MCG-4427-070617

B/34, B/35 (M)

Yellow and black mastic associated with Unknown sized beige floor tile (above)

Under dark gray carpet squares in ramp to outside ND

MCG-4427-070617

B/36, B/37

2'x2' White ceiling tile -small sized worm and pinholes

VIP Lounge Ceiling ND

MCG-4427-070617

B/38, B/39 (FT) Beige floor tile Right side of Radio Room (far back right corner) 7% Chrysotile

MCG-4427-070617

B/38, B/39 (M1)

Black mastic on beige floor tile (above)

Right side of Radio Room (far back right corner) ND

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 11

MCG-4427-070617

B/38, B/39 (M2)

Yellow carpet mastic on beige floor tile (above)

Right side of Radio Room (far back right corner) ND

MCG-4427-070617

B/41, B/42 (CB) Dark gray baseboard Along base of carpeted Radio counter ND

MCG-4427-070617

B/41, B/42 (M)

Beige mastic on dark gray baseboard (above)

Along base of carpeted Radio counter ND

MCG-4427-070617

B/43, B/44 Dark brown window caulk Window along runway side ND

Key: FT=Floor Tile, M=Mastic, CB=Cove base, ND=Non-detect

4.3 ASBESTOS CONCLUSIONS

Materials considered to be potential ACM were sampled. Many samples were non-detect for asbestos, and, therefore, those materials are not considered ACM. Safety and health procedures normally employed during construction activity may be used for the removal, demolition, and disposal of these non-ACBM.

Given the ubiquitous presence of carpeting and carpet adhesive, it is difficult to determine the exact locations of ACM floor tile. The drawing represents the Inspector’s “educated guess” as to the extent.

One material was found to have greater than 1% asbestos content, and three components were not sampled and should be assumed asbestos-containing. These materials, therefore, should be treated as regulated asbestos-containing materials (RACM). RACM is defined as friable asbestos material or non-friable asbestos-containing material (ACM) that will be, or has been, subjected to sanding, grinding, cutting, or abrading or has crumbled, pulverized, or reduced to powder during demolition or renovation operations.

The following materials are RACM:

Asbestos-Containing Material Location and Extent

Beige Floor Tile Under dark gray “ramp” carpeting, and various locations under gray carpeting around Radio Counter; potentially throughout.

Fire Door (PACM) Mechanical Room

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 12

Roofing materials (PACM) Exterior Roof

Brown and Black Fibrous Paneling Attic Space

These materials have been identified as asbestos-containing or presumed asbestos-containing materials, and wherever these materials are found, they shall be removed in accordance state and federal regulations.

All quantities must be field-verified by a licensed asbestos abatement contractor(s) prior to demolition or renovation.

Sampling locations and positively-identified materials are identified on Drawings presented in Attachment 6.

5.0 LEAD-BASED PAINT INSPECTION REPORT

The Facility was assessed for the presence of Lead-Based Paint (LBP) materials on July 6, 2017. All occupied areas of the facility were made accessible for inspection.

This inspection was conducted by GLOBAL’s IH personnel, and the results are presented in Section 5.1 LBP Inspection Report.

5.1 LBP INSPECTION REPORT

Testing for LBP was conducted using a NITON XLp XRF-type analyzer (serial number 18595). Prior to XRF analysis, the instrument was calibrated against reference standards of known lead concentrations. Doors, door frames, windows, window frames, window sills, walls, ceilings, pipes, and other miscellaneous painted surfaces and building materials were screened for LBP.

The XRF detects lead in the field by reading fluorescence emanating from a painted surface when exposed to small amounts of radiation. XRF readings are in milligrams per square centimeter (mg/cm2), a mass per area unit. LBP is defined as a point containing greater than 1.0 mg/cm2 lead according to the New Jersey Department of the Environmental Protection. Prior to testing, the composition of the test building substrate (e.g., wood, metal, etc.) was determined by the lead inspector, and subsequently logged into the XRF analyzer. The NITON XLp automatically performs a substrate correction to ensure that this factor does not result in false negative readings.

At the end of each sampling session a calibration re-check is performed to ensure that the instrument has maintained accuracy and precision during the measurement period.

The instrument is also calibrated each time it is turned off, or on, and typically at four (4) hour intervals during the workday for the same reasons. The use of the XRF was in general accordance with the Performance Characteristic Sheet (PCS) methodology for

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 13 the specific instrument. XRF instrument calibration checks were performed according to the PCS.

5.2 LBP INSPECTION DATA

The NITON XLp XRF data was downloaded directly to a computer to generate a report detailing the date/time, materials sampled, location, substrate and lead content. This inspection included only painted surfaces.

During the XRF survey, the four sides of each structure were designated as A, B, C or D.

Side A = Northern side of the building facing the water front Side B = Walls located to the left (clockwise) of side A.

Side C = Walls located opposite side A.

Side D = Walls located to the right of Side A

The annotated and raw data is presented in Attachment 3. Photos may be found in Attachment 4.

5.3 LBP INSPECTION RESULTS

Most of the structures tested were found to be below the standard that indicates they are LBP according to the New Jersey Department of Environmental Protection.

Lead-based paint is defined as any paint, varnish, shellac, or other coating that contains lead greater than 1.0 mg/cm2 as measured by XRF analysis.

The following materials were found to be coated in LBP:

1. White paint under roof on exterior of the building behind the soffit

2. Yellow/White exterior window lintels

3. White paint on concrete block in the radio room

4. Any un-noted paint found inside the ceiling plenum, under wall paper, or under the roof, fascia, or soffit if found during demolition should be assumed to contain lead paint

5. Similar materials to those denoted above should be assumed positive

5.4 LBP ABATEMENT REQUIREMENTS

The contractor performing demolition shall characterize the LBP materials to be demolished using ASTM E-1908 and if the material passes the EPA Landfill criteria as determined by a Toxic Chemical Leaching Procedure (TCLP) it may be disposed of as normal construction waste in a facility licensed to accept the materials. The contractor shall remove the materials as a whole component to the greatest extent possible and shall properly characterize each waste stream for disposal. In addition to adopting many of the federal standards for General Industry (29 CFR 1910), Construction (29 CFR

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 14

1926), and Agriculture (29 CFR 1928), the New Jersey Department of Health (NJDOH) has supplemented the federal standards with several requirements unique to New Jersey.

Contractors must be trained and accredited through the New Jersey Department of Health and employed by a lead firm licensed by the New Jersey Department of Community Affairs (DOCA) when a permit is needed. Lead paint contractors include those who work on residential, public, and commercial buildings as well as the maintenance work required in rental housing; structural steel projects, such as bridges, water tanks, and industrial structures; and conduct lead paint inspections. Abatement supervisors and workers must be trained in accordance with New Jersey state laws.

6.0 POLYCHLORINATED BIPHENYLS (PCBS)

PCBs are regulated under the EPA’s Toxic Substances Control Act of 1976 (TSCA).

The following materials were tested for PCBs:

• Caulking on the windows facing the parking lot and front entrance

• Caulking on the window facing the Army Ramp

None of the above materials tested positive for PCBs at the time of the inspection.

Laboratory results are attached at the end of this report.

There is low possibility that some PCB-containing light ballasts exist in the facility.

Should potentially PCB-containing ballasts be encountered during renovation, they should be managed and disposed of in accordance with TSCA Storage Disposal Requirements for Fluorescent Light Ballasts.

Sampling locations materials are identified on Drawings presented in Attachment 5.

7.0 UNIVERSAL WASTES AND OZONE-DEPLETING SUBSTANCES

EPA's Universal Waste (UW) regulations are promulgated in 40 CFR 273. This regulation sets hazardous waste management standards for federally designated "universal wastes," which include:

• Batteries

• Pesticides

• Mercury-containing equipment and

• Bulbs (lamps)

The regulations are alternate standards for the handling of UW. In contrast to the requirements found in 40 CFR 260 through 272, UW should be segregated and disposed of every 90 days, and in accordance with Federal, state, and local regulations.

Disposal and management of such bulbs is regulated by the Recreation Conservation and Recovery Act (RCRA) Universal Waste Rule (UWR) and should be handed in http://www.epa.gov/waste/hazard/wastetypes/universal/batteries.htm http://www.epa.gov/waste/hazard/wastetypes/universal/pesticides.htm http://www.epa.gov/waste/hazard/wastetypes/universal/mce.htm http://www.epa.gov/waste/hazard/wastetypes/universal/lamps/index.htm

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 15 accordance with this rule. All future identified UW should be properly packaged and disposed of in accordance with Universal Waste rules.

Global did not identify any fluorescent lightbulbs at the time of the survey. Should any stored fluorescent bulbs be found on the site, they should be considered waste. Disposal and management of spent bulbs are regulated by the Recreation Conservation and Recovery Act (RCRA) Universal Waste Rule (UWR), and should be handed and disposed of in accordance with this rule.

8.0 DISCLAIMER

Information in this inspection report relating to hazardous materials (i.e., asbestos and lead), although believed to be inclusive and accurate, was based on visual observations and field sampling of accessible areas. Limiting conditions included limited destructive sampling and inaccessible areas such as between walls and floors of the structures, and limited subsurface assessment of the property. Reasonable efforts are made to extrapolate where possible such as where insulated pipe runs into and through a wall.

Global, Inc. reserves the right to revise any recommendations and conclusions, and does not guarantee or accept any liability that encompasses this survey of all hazardous or regulated materials located within this building.

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 16

ATTACHMENT 1 – ASBESTOS RESULTS

EMSL Analytical, Inc.

10768 Baltimore Avenue Beltsville, MD 20705

Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com

191707698EMSL Order:

Customer ID: GLBW42

Customer PO:

Project ID:

Attention: Phone:Judi Darnell (202) 832-1433

Fax:Global Inc.

Received Date:1818 New York Avenue NE 07/07/2017 1:40 PM

Analysis Date:Suite 222 07/07/2017 - 07/11/2017

Collected Date:Washington, DC 20002 07/06/2017

Project: 17-023 JACOBS MCGUIRE

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

MCG-4427-070617-B/1

191707698-0001

None DetectedQuartz

Non-fibrous (Other)

10%

70%

Glass20%Tan

Fibrous

Homogeneous

CREAM STUCCO

SURFACING

MATERIAL-EXTERIO

R WALLS

MCG-4427-070617-B/2

191707698-0002

None DetectedQuartz

Non-fibrous (Other)

10%

75%

Glass15%Tan

Fibrous

Homogeneous

CREAM STUCCO

SURFACING

MATERIAL-EXTERIO

R WALLS

MCG-4427-070617-B/3

191707698-0003

None DetectedQuartz

Non-fibrous (Other)

20%

55%

Glass25%Gray/Black

Fibrous

Heterogeneous

GRAY SHINGLE AND

BLACK TAR-ROOF

MCG-4427-070617-B/4

191707698-0004

None DetectedQuartz

Non-fibrous (Other)

20%

55%

Glass25%Brown/Black

Fibrous

Heterogeneous

GRAY SHINGLE AND

BLACK TAR-ROOF

MCG-4427-070617-B/5

191707698-0005

None DetectedNon-fibrous (Other)93%Synthetic7%Gray/Black

Fibrous

Heterogeneous

GRAY WINDOW

CAULK

(HARD)-EXTERIOR

WINDOWS

MCG-4427-070617-B/6

191707698-0006

None DetectedNon-fibrous (Other)95%Synthetic5%Gray

Non-Fibrous

Homogeneous

GRAY WINDOW

CAULK

(HARD)-EXTERIOR

WINDOWS

MCG-4427-070617-B/7

191707698-0007

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

GRAY GUTTER

SEAM

SEALANT-EXTERIO

R ALONG ROOF

MCG-4427-070617-B/8

191707698-0008

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

GRAY GUTTER

SEAM

SEALANT-EXTERIO

R ALONG ROOF

MCG-4427-070617-B/9-

Floor Tile

191707698-0009

None DetectedCa Carbonate

Non-fibrous (Other)

55%

45%

Gray/White

Non-Fibrous

Homogeneous

12"X12" FT LIGHT

CREAM WITH GRAY

SPECKLES &

YELLOW MASTIC

MCG-4427-070617-B/9-

Mastic

191707698-0009A

None DetectedNon-fibrous (Other)98%Cellulose2%Yellow

Non-Fibrous

Homogeneous

12"X12" FT LIGHT

CREAM WITH GRAY

SPECKLES &

YELLOW MASTIC

MCG-4427-070617-B/1

0-Floor Tile

191707698-0010

None DetectedCa Carbonate

Non-fibrous (Other)

55%

45%

Gray/White

Non-Fibrous

Homogeneous

12"X12" FT LIGHT

CREAM WITH GRAY

SPECKLES &

YELLOW MASTIC

MCG-4427-070617-B/1

0-Mastic

191707698-0010A

None DetectedNon-fibrous (Other)98%Cellulose2%Yellow

Non-Fibrous

Homogeneous

12"X12" FT LIGHT

CREAM WITH GRAY

SPECKLES &

YELLOW MASTIC

MCG-4427-070617-B/11

-Cove Base

191707698-0011

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

Tan

Non-Fibrous

Homogeneous

BLACK BASEBOARD

WITH TAN

MASTIC-WOMEN'S

RESTROOM

Initial report from: 07/11/2017 11:06:50

Page 1 of 7ASB_PLM_0008_0001 - 1.78 Printed: 7/17/2017 9:11 AM

Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com

191707698EMSL Order:

Customer ID: GLBW42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

MCG-4427-070617-B/11

-Mastic

191707698-0011A

None DetectedNon-fibrous (Other)90%Cellulose10%Tan

Non-Fibrous

Homogeneous

BLACK BASEBOARD

WITH TAN

MASTIC-WOMEN'S

RESTROOM

MCG-4427-070617-B/1

2-Cove Base

191707698-0012

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

Black

Non-Fibrous

Homogeneous

TAN MASTIC UNDER

BLACK BASEBOARD

MCG-4427-070617-B/1

2-Mastic

191707698-0012A

None DetectedNon-fibrous (Other)90%Cellulose10%Tan

Non-Fibrous

Homogeneous

TAN MASTIC UNDER

BLACK BASEBOARD

MCG-4427-070617-B/1

3-Floor Tile

191707698-0013

None DetectedCa Carbonate

Non-fibrous (Other)

55%

45%

Gray

Non-Fibrous

Homogeneous

12"X12" FT DARK

GRAY FT WITH

YELLOW

MASTIC-MECH

ROOM

MCG-4427-070617-B/1

3-Mastic

191707698-0013A

None DetectedNon-fibrous (Other)97%Cellulose3%Yellow

Non-Fibrous

Homogeneous

12"X12" FT DARK

GRAY FT WITH

YELLOW

MASTIC-MECH

ROOM

MCG-4427-070617-B/1

4-Floor Tile

191707698-0014

None DetectedCa Carbonate

Non-fibrous (Other)

55%

45%

Gray

Non-Fibrous

Homogeneous

12"X12" FT DARK

GRAY FT WITH

YELLOW

MASTIC-MECH

ROOM

MCG-4427-070617-B/1

4-Mastic

191707698-0014A

None DetectedNon-fibrous (Other)97%Cellulose3%Yellow

Non-Fibrous

Homogeneous

12"X12" FT DARK

GRAY FT WITH

YELLOW

MASTIC-MECH

ROOM

MCG-4427-070617-B/1

191707698-0015

None DetectedGypsum

Non-fibrous (Other)

65%

25%

Cellulose10%Brown/Gray

Fibrous

Heterogeneous

DRYWALL-WHITE

WITH BROWN

PAPER-MECH

ROOM

MCG-4427-070617-B/1

191707698-0016

None DetectedGypsum

Non-fibrous (Other)

70%

15%

Cellulose

Glass

10%

5%

Brown/Gray

Non-Fibrous

Homogeneous

DRYWALL-WHITE

WITH BROWN

PAPER-MECH

ROOM

MCG-4427-070617-B/1

7-Cove Base

191707698-0017

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

Brown

Non-Fibrous

Homogeneous

BROWN

BASEBOARD WITH

YELLOW

MASTIC-MECH

ROOM

MCG-4427-070617-B/1

7-Mastic

191707698-0017A

None DetectedNon-fibrous (Other)99%Synthetic1%Yellow

Non-Fibrous

Homogeneous

BROWN

BASEBOARD WITH

YELLOW

MASTIC-MECH

ROOM

MCG-4427-070617-B/1

191707698-0018

None DetectedMica

Non-fibrous (Other)

10%

85%

Cellulose5%White

Non-Fibrous

Homogeneous

WHITE JOINT

COMPOUND-MECH

ROOM

MCG-4427-070617-B/1

191707698-0019

None DetectedNon-fibrous (Other)10%Glass90%White

Fibrous

Homogeneous

WHITE FLUE

INSULATINO-MECH

ROOM

Page 2 of 7ASB_PLM_0008_0001 - 1.78 Printed: 7/17/2017 9:11 AM

Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com

191707698EMSL Order:

Customer ID: GLBW42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

MCG-4427-070617-B/2

191707698-0020

None DetectedNon-fibrous (Other)15%Min. Wool85%Gray/White

Fibrous

Homogeneous

WHITE FLUE

INSULATINO-MECH

ROOM

MCG-4427-070617-B/2

1-Floor Tile

191707698-0021

None DetectedCa Carbonate

Non-fibrous (Other)

60%

40%

Blue

Non-Fibrous

Homogeneous

12"X12" BRIGHT

BLUE FT WITH

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

1-Mastic

191707698-0021A

None DetectedNon-fibrous (Other)97%Cellulose3%Yellow

Non-Fibrous

Homogeneous

12"X12" BRIGHT

BLUE FT WITH

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

2-Floor Tile

191707698-0022

None DetectedCa Carbonate

Non-fibrous (Other)

55%

45%

Blue

Non-Fibrous

Homogeneous

12"X12" BRIGHT

BLUE FT WITH

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

2-Mastic

191707698-0022A

None DetectedNon-fibrous (Other)97%Cellulose3%Yellow

Non-Fibrous

Homogeneous

12"X12" BRIGHT

BLUE FT WITH

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

3-Cove Base

191707698-0023

None DetectedCa Carbonate

Non-fibrous (Other)

20%

80%

Blue

Non-Fibrous

Homogeneous

DARK BLUE

BASEBOARD WITH

GRAY

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

3-Mastic

191707698-0023A

None DetectedNon-fibrous (Other)95%Cellulose5%White

Non-Fibrous

Homogeneous

DARK BLUE

BASEBOARD WITH

GRAY

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

4-Cove Base

191707698-0024

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

Blue

Non-Fibrous

Homogeneous

DARK BLUE

BASEBOARD WITH

GRAY

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

4-Mastic

191707698-0024A

None DetectedNon-fibrous (Other)97%Cellulose3%White

Non-Fibrous

Homogeneous

DARK BLUE

BASEBOARD WITH

GRAY

MASTIC-MEN'S

RESTROOM

MCG-4427-070617-B/2

191707698-0025

None DetectedPerlite

Non-fibrous (Other)

25%

30%

Cellulose

Glass

35%

10%

Gray/White

Fibrous

Homogeneous

2'X2' WHITE

CEILING

TILE-MEDIUM SIZED

WORM AND

PINHOLES-LOUNGE

OUTSIDE OF MEN'S

ROOM

MCG-4427-070617-B/2

191707698-0026

None DetectedNon-fibrous (Other)85%Cellulose

Synthetic

10%

5%

Brown/Black

Fibrous

Homogeneous

CARPET MASTIC

AND MISC FLOOR

MASTICS-LOUNGE

UNDER

CARPET-THROUGH

OUT

MCG-4427-070617-B/2

191707698-0027

None DetectedNon-fibrous (Other)94%Cellulose

Synthetic

3%

3%

Brown/Gray

Non-Fibrous

Homogeneous

CARPET MASTIC

AND MISC FLOOR

MASTICS-LOUNGE

UNDER

CARPET-THROUGH

OUT

Page 3 of 7ASB_PLM_0008_0001 - 1.78 Printed: 7/17/2017 9:11 AM

Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com

191707698EMSL Order:

Customer ID: GLBW42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

MCG-4427-070617-B/2

8-Floor Tile

191707698-0028

None DetectedCa Carbonate

Non-fibrous (Other)

55%

45%

Gray/Tan

Non-Fibrous

Homogeneous

12"X12" MEDIUM

GRAY MOTTLED FT

AND TAN

MASTIC-ELECT/PHO

NE ROOM (REAR)

MCG-4427-070617-B/2

8-Mastic

191707698-0028A

None DetectedNon-fibrous (Other)97%Cellulose3%Yellow

Non-Fibrous

Homogeneous

12"X12" MEDIUM

GRAY MOTTLED FT

AND TAN

MASTIC-ELECT/PHO

NE ROOM (REAR)

MCG-4427-070617-B/2

9-Floor Tile

191707698-0029

None DetectedCa Carbonate

Non-fibrous (Other)

55%

45%

Beige

Non-Fibrous

Homogeneous

REMNANTS OF

12"X12" BEIGE WITH

TAN SPECKLES FT,

WITH BLACK AND

YELLOW

MASTIC-ALONG

THRESHOLD INTO

ELECT/PHONE

ROOM (REAR); AND

UNDER OFFICE

DOOR

MCG-4427-070617-B/2

9-Mastic

191707698-0029A

None DetectedNon-fibrous (Other)97%Cellulose

Synthetic

2%

1%

Gray/Yellow

Non-Fibrous

Homogeneous

REMNANTS OF

12"X12" BEIGE WITH

TAN SPECKLES FT,

WITH BLACK AND

YELLOW

MASTIC-ALONG

THRESHOLD INTO

ELECT/PHONE

ROOM (REAR); AND

UNDER OFFICE

DOOR

MCG-4427-070617-B/3

191707698-0030

None DetectedNon-fibrous (Other)85%Glass15%Red/Black

Fibrous

Homogeneous

RED FIRE

STOP-ELECT/PHON

E ROOM (FRONT)

MCG-4427-070617-B/3

191707698-0031

None DetectedGypsum

Non-fibrous (Other)

65%

20%

Cellulose15%Tan/White

Fibrous

Heterogeneous

DRYWALL-WHITE

WITH BROWN

PAPER-ELECT/PHO

NE ROOM (FRONT)

MCG-4427-070617-B/3

2-Leveler

191707698-0032

None DetectedNon-fibrous (Other)95%Cellulose5%White

Non-Fibrous

Homogeneous

WHITE FLOOR

LEVELING

COMPOUND WITH

TAN CARPET

MASTIC-THRESHOL

D AT OFFICE DOOR

MCG-4427-070617-B/3

2-Mastic

191707698-0032A

None DetectedNon-fibrous (Other)97%Synthetic3%Yellow

Non-Fibrous

Homogeneous

WHITE FLOOR

LEVELING

COMPOUND WITH

TAN CARPET

MASTIC-THRESHOL

D AT OFFICE DOOR

MCG-4427-070617-B/3

191707698-0033

None DetectedPerlite

Non-fibrous (Other)

25%

20%

Cellulose

Glass

45%

10%

Gray/White

Fibrous

Homogeneous

2'X2' WHITE

CEILING

TILE-MEDIUM SIZED

WORM AND

PINHOLES-OFFICE

Page 4 of 7ASB_PLM_0008_0001 - 1.78 Printed: 7/17/2017 9:11 AM

Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com

191707698EMSL Order:

Customer ID: GLBW42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

MCG-4427-070617-B/3

4-Floor Tile

191707698-0034

5% ChrysotileNon-fibrous (Other)95%Tan/Beige

Non-Fibrous

Homogeneous

UNKNOWN SIZED

BIEGE FT W/

YELLOW AND

BLACK

MASTIC-UNDER

DARK GRAY

CARPET SQUARES

IN RAMP TO

OUTSIDE

MCG-4427-070617-B/3

4-Mastic

191707698-0034A

None DetectedNon-fibrous (Other)96%Cellulose

Synthetic

3%

1%

Black/Yellow

Non-Fibrous

Homogeneous

UNKNOWN SIZED

BIEGE FT W/

YELLOW AND

BLACK

MASTIC-UNDER

DARK GRAY

CARPET SQUARES

IN RAMP TO

OUTSIDE

Composite Yellow and Black Mastic

MCG-4427-070617-B/3

5-Floor Tile

191707698-0035

Positive Stop (Not Analyzed)UNKNOWN SIZED

BIEGE FT W/

YELLOW AND

BLACK

MASTIC-UNDER

DARK GRAY

CARPET SQUARES

IN RAMP TO

OUTSIDE

MCG-4427-070617-B/3

5-Mastic

191707698-0035A

None DetectedNon-fibrous (Other)96%Cellulose

Synthetic

3%

1%

Black/Yellow

Non-Fibrous

Homogeneous

UNKNOWN SIZED

BIEGE FT W/

YELLOW AND

BLACK

MASTIC-UNDER

DARK GRAY

CARPET SQUARES

IN RAMP TO

OUTSIDE

MCG-4427-070617-B/3

191707698-0036

None DetectedPerlite

Non-fibrous (Other)

25%

25%

Cellulose

Glass

35%

15%

Gray/White

Fibrous

Homogeneous

2'X2' WHITE

CEILING

TILE-SMALL SIZED

WORM AND

PINHOLES-VIP

LOUNGE CEILING

MCG-4427-070617-B/3

191707698-0037

None DetectedPerlite

Non-fibrous (Other)

30%

20%

Cellulose

Glass

35%

15%

Gray/White

Fibrous

Homogeneous

2'X2' WHITE

CEILING

TILE-SMALL SIZED

WORM AND

PINHOLES-VIP

LOUNGE CEILING

MCG-4427-070617-B/3

191707698-0038

7% ChrysotileNon-fibrous (Other)93%Beige

Non-Fibrous

Homogeneous

BEIGE FT WITH

BLACK MASTIC AND

YELLOW CARPET

MASTIC-RIGHT SIDE

OF RADIO ROOM

(FAR BACK RIGHT

CORNER)

Page 5 of 7ASB_PLM_0008_0001 - 1.78 Printed: 7/17/2017 9:11 AM

Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com

191707698EMSL Order:

Customer ID: GLBW42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

MCG-4427-070617-B/3

8-Mastic

191707698-0038A

None DetectedNon-fibrous (Other)99%Cellulose1%Black

Non-Fibrous

Homogeneous

BEIGE FT WITH

BLACK MASTIC AND

YELLOW CARPET

MASTIC-RIGHT SIDE

OF RADIO ROOM

(FAR BACK RIGHT

CORNER)

MCG-4427-070617-B/3

8-Mastic 2

191707698-0038B

None DetectedNon-fibrous (Other)95%Synthetic5%Yellow

Fibrous

Homogeneous

BEIGE FT WITH

BLACK MASTIC AND

YELLOW CARPET

MASTIC-RIGHT SIDE

OF RADIO ROOM

(FAR BACK RIGHT

CORNER)

MCG-4427-070617-B/3

9-Floor Tile

191707698-0039

Positive Stop (Not Analyzed)BEIGE FT WITH

BLACK MASTIC AND

YELLOW CARPET

MASTIC-RIGHT SIDE

OF RADIO ROOM

(FAR BACK RIGHT

CORNER)

MCG-4427-070617-B/3

9-Mastic

191707698-0039A

None DetectedNon-fibrous (Other)99%Cellulose1%Black

Non-Fibrous

Homogeneous

BEIGE FT WITH

BLACK MASTIC AND

YELLOW CARPET

MASTIC-RIGHT SIDE

OF RADIO ROOM

(FAR BACK RIGHT

CORNER)

MCG-4427-070617-B/3

9-Mastic 2

191707698-0039B

None DetectedNon-fibrous (Other)97%Synthetic3%Yellow

Fibrous

Homogeneous

BEIGE FT WITH

BLACK MASTIC AND

YELLOW CARPET

MASTIC-RIGHT SIDE

OF RADIO ROOM

(FAR BACK RIGHT

CORNER)

MCG-4427-070617-B/4

0-Floor Tile

191707698-0040

None DetectedCa Carbonate

Non-fibrous (Other)

60%

40%

Gray

Non-Fibrous

Homogeneous

12"X12" GRAY

MOTTLED FT W/

BLACK AND

YELLOW

MASTIC-SMALL

RADIO CLOSET

MCG-4427-070617-B/4

0-Mastic

191707698-0040A

None DetectedNon-fibrous (Other)97%Cellulose3%Black/Yellow

Non-Fibrous

Homogeneous

12"X12" GRAY

MOTTLED FT W/

BLACK AND

YELLOW

MASTIC-SMALL

RADIO CLOSET

Composite Yellow and Black Mastic

MCG-4427-070617-B/4

1-Cove Base

191707698-0041

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

Gray

Non-Fibrous

Homogeneous

DARK GRAY

BASEBOARD WITH

BEIGE

MASTIC-ALONG

BASE OF

CARPETED RADIO

COUNTER

Page 6 of 7ASB_PLM_0008_0001 - 1.78 Printed: 7/17/2017 9:11 AM

Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com

191707698EMSL Order:

Customer ID: GLBW42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

MCG-4427-070617-B/4

1-Mastic

191707698-0041A

None DetectedNon-fibrous (Other)98%Cellulose2%Tan

Non-Fibrous

Homogeneous

DARK GRAY

BASEBOARD WITH

BEIGE

MASTIC-ALONG

BASE OF

CARPETED RADIO

COUNTER

MCG-4427-070617-B/4

2-Cove Base

191707698-0042

None DetectedCa Carbonate

Non-fibrous (Other)

20%

80%

Gray

Non-Fibrous

Homogeneous

DARK GRAY

BASEBOARD WITH

BEIGE

MASTIC-ALONG

BASE OF

CARPETED RADIO

COUNTER

MCG-4427-070617-B/4

2-Mastic

191707698-0042A

None DetectedNon-fibrous (Other)88%Synthetic12%Tan

Fibrous

Homogeneous

DARK GRAY

BASEBOARD WITH

BEIGE

MASTIC-ALONG

BASE OF

CARPETED RADIO

COUNTER

MCG-4427-070617-B/4

191707698-0043

None DetectedQuartz

Non-fibrous (Other)

2%

98%

Brown

Non-Fibrous

Homogeneous

DARK BROWN

WINDOW

CAULK-WINDOW

ALONG RUNAWAY

SIDE

MCG-4427-070617-B/4

191707698-0044

None DetectedQuartz

Non-fibrous (Other)

1%

99%

Brown

Non-Fibrous

Homogeneous

DARK BROWN

WINDOW

CAULK-WINDOW

ALONG RUNAWAY

SIDE

MCG-4427-070617-B/4

191707698-0045

None DetectedQuartz

Non-fibrous (Other)

2%

98%

Brown

Non-Fibrous

Homogeneous

DARK BROWN

WINDOW

CAULK-WINDOW

ALONG RUNAWAY

SIDE

Analyst(s)

Luba Stockert (66) Joe Centifonti, Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. Beltsville, MD NVLAP Lab Code 200293-0

Page 7 of 7ASB_PLM_0008_0001 - 1.78 Printed: 7/17/2017 9:11 AM

OrderID: 191707698 Page 1 Of

Page 2 Of

Page 3 Of

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 17

ATTACHMENT 2 – ACM PHOTOS

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 18

Carpet Squares on Ramp (over Positive FT) Beige FT under carpeting

Beige FT in corner by Radio Dispatch Fiber board in attic (PACM)

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 19

ATTACHMENT 3 – LBP RESULTS

Time Action LeveComponent Substrate Side Condition Color Floor Room Results PbC 7/6/2017 9:21 1 CALIBRATE Positive 1.1 7/6/2017 9:21 1 CALIBRATE Positive 1.1 7/6/2017 9:23 1 CALIBRATE Positive 1 7/6/2017 9:24 1 WALL CONCRETE A INTACT TAN FIRST OUTSIDE Negative 0 7/6/2017 9:27 1 SOFFIT METAL A INTACT BROWN FIRST OUTSIDE Negative 0.02 7/6/2017 9:27 1 WINDOW SASH METAL A INTACT BLACK FIRST OUTSIDE Negative ‐0.03 7/6/2017 9:29 1 under roof trim/lintel WOOD A PEELING WHITE/Tan FIRST OUTSIDE Positive 13.9 7/6/2017 9:32 1 DOOR METAL A INTACT BROWN FIRST OUTSIDE Negative 0 7/6/2017 9:33 1 WALL DRYWALL A INTACT PINK FIRST womens bathroom Negative 0 7/6/2017 9:33 1 WALL DRYWALL D INTACT PINK FIRST womens bathroom Negative 0 7/6/2017 9:34 1 WINDOW SASH METAL A INTACT YELLOW FIRST womens bathroom Negative 0 7/6/2017 9:35 1 WALL DRYWALL C INTACT grey wallpaper FIRST Crew Lounge Negative 0 7/6/2017 9:35 1 WALL DRYWALL C INTACT grey wallpaper FIRST Crew Lounge Negative 0 7/6/2017 9:36 1 WALL DRYWALL A INTACT grey wallpaper FIRST Crew Lounge Negative 0 7/6/2017 9:37 1 WALL DRYWALL A INTACT grey wallpaper FIRST DV Lounge Negative 0 7/6/2017 9:37 1 WALL DRYWALL D INTACT grey wallpaper FIRST DV Lounge Negative 0 7/6/2017 9:39 1 DOOR METAL A INTACT BLACK FIRST DV Lounge Negative ‐0.04 7/6/2017 9:40 1 WALL DRYWALL D INTACT WHITE FIRST RADIO ROOM Negative 0.01 7/6/2017 9:40 1 WALL WOOD C INTACT GREEN FIRST RADIO ROOM Negative 0.8 7/6/2017 9:41 1 WALL CONCRETE C INTACT WHITE FIRST RADIO ROOM Positive 1.5 7/6/2017 9:42 1 CEILING DRYWALL UPPER INTACT WHITE FIRST RADIO ROOM Negative 0 7/6/2017 9:44 1 DOOR FRAME METAL A INTACT PINK FIRST ELECTRIC CLOSET Negative 0 7/6/2017 9:45 1 WALL WOOD C INTACT WHITE FIRST ELECTRIC CLOSET Negative 0 7/6/2017 9:45 1 WALL DRYWALL C INTACT WHITE FIRST ELECTRIC CLOSET Negative 0 7/6/2017 9:46 1 WALL DRYWALL D INTACT WHITE FIRST ELECTRIC CLOSET BACK A Negative 0 7/6/2017 9:47 1 WALL DRYWALL B INTACT WHITE FIRST ELECTRIC CLOSET BACK A Negative 0 7/6/2017 9:47 1 WALL DRYWALL B INTACT BLUE FIRST mens room Negative 0 7/6/2017 9:48 1 WALL DRYWALL A INTACT BLUE FIRST mens room Negative 0 7/6/2017 9:53 1 WALL DRYWALL A INTACT WHITE FIRST mech room Negative 0.01 7/6/2017 9:53 1 WALL DRYWALL C INTACT WHITE FIRST mech room Negative 0 7/6/2017 9:54 1 DOOR FRAME WOOD D INTACT WHITE FIRST mech room Negative 0

7/6/2017 10:39 1 DIFFUSER METAL UPPER INTACT BEIGE FIRST crew lounge Negative 0.01 7/6/2017 10:44 1 WALL BELOW CHAIR RAIL DRYWALL A INTACT white pink wallpaper FIRST crew lounge Negative 0.01 7/6/2017 10:44 1 WALL BELOW CHAIR RAIL DRYWALL C INTACT white pink wallpaper FIRST crew lounge Negative 0 7/6/2017 11:03 1 CALIBRATE Positive 1.2 7/6/2017 11:03 1 CALIBRATE Negative 0.9 7/6/2017 11:04 1 CALIBRATE Positive 1

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 20

ATTACHMENT 4 – LBP PHOTOS

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 21

Tan/White paint on exterior window lintels White paint under roof on exterior

White paint on concrete block in the radio room

Joint Base McGuire-Dix-Lakehurst (JB MDL, NJ) Hazardous Materials Survey

July 27, 2017 Page 22

ATTACHMENT 6 – PCB RESULTS

ANALYTICAL REPORT

Lauren Kesslak, MS Global Consulting, Inc.

1818 New York Avenue NE Suite 111 Washington, DC 20002

Phone:

Fax:

E-mail:

(202) 832-1433

(202) 832-1434 lkesslak@gciusa.biz

Report Date: July 26, 2017

34-1719351Workorder:

Fort Dix, NJ 070617 Fort Dix, NJPurchase Order:

Project ID:

Project Manager Paul E. Pope

Sampling SiteReceive DateCollect DateLab IDClient Sample ID

1719351001 07/06/17FD/70617-01 07/12/17 Fort Dix, NJ

1719351002 07/06/17FD/70617-02 07/12/17 Fort Dix, NJ

Page 1 of 4 Wed, 07/26/17 3:10 PM ENVREP-V4.6

ADDRESS 960 West LeVoy Drive, Salt Lake City, Utah, 84123 USA PHONE FAX+1 801 266 7700 +1 801 268 9992

ALS GROUP USA, CORP. An ALS Limited Company

Project Manager: Paul E. Pope Client: Global Consulting, Inc.

Workorder: 34-1719351

Analytical Results

Sample ID: 07/06/2017 07/12/20171719351001Lab ID:

Collected:

Received:

FD/70617-01 Fort Dix, NJ

Sampling Parameter: NAMatrix:

Media:

Bulk 4 oz Amber Glass Jar

Sampling Site:

Analysis: SW 8082, Bulk

Analyzed: 07/25/2017 00:00 Batch:

Instrument ID:

EGC/6947 (HBN: 195250) Percent Solid: NA

GCE03

Report Basis: Wet

Preparation: EPA 3550, Sonic Ext, ARO Bulk

Prepared: 07/13/2017 Batch:

Weight/Volume ENVX/25190 (HBN: 194466) Initial:

Final:

1.7 grams 10 mL

Result (ug/g)Analyte RL (ug/g) Dilution Qual

Analysis Method - SW 8082

0.12<0.12 1Aroclor 1221

0.059<0.059 1Aroclor 1232

0.059<0.059 1Aroclor 1016

0.059<0.059 1Aroclor 1242

0.059<0.059 1Aroclor 1248

0.059<0.059 1Aroclor 1254

0.059<0.059 1Aroclor 1260

0.059<0.059 1Aroclor 1262

0.059<0.059 1Aroclor 1268

Sample ID: 07/06/2017 07/12/20171719351002Lab ID:

Collected:

Received:

FD/70617-02 Fort Dix, NJ

Sampling Parameter: NAMatrix:

Media:

Bulk 4 oz Amber Glass Jar

Sampling Site:

Analysis: SW 8082, Bulk

Analyzed: 07/25/2017 00:00 Batch:

Instrument ID:

EGC/6947 (HBN: 195250) Percent Solid: NA

GCE03

Report Basis: Wet

Preparation: EPA 3550, Sonic Ext, ARO Bulk

Prepared: 07/13/2017 Batch:

Weight/Volume ENVX/25190 (HBN: 194466) Initial:

Final:

3.13 grams 10 mL

Result (ug/g)Analyte RL (ug/g) Dilution Qual

Analysis Method - SW 8082

0.064<0.064 1Aroclor 1221

0.032<0.032 1Aroclor 1232

0.032<0.032 1Aroclor 1016

0.032<0.032 1Aroclor 1242

0.032<0.032 1Aroclor 1248

0.032<0.032 1Aroclor 1254

0.032<0.032 1Aroclor 1260

0.032<0.032 1Aroclor 1262

0.032<0.032 1Aroclor 1268

Report Authorization

Analyst Peer ReviewMethod

(/S/ is an electronic…