This document outlines a competitive 8(a) Invitation for Bid for the construction of an F-16 flight simulator facility at Joint Base Andrews in Maryland. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Baltimore as solicitation number W912DR22B0004. Interested parties should review the accompanying solicitation and attachments for full details regarding the requirement, which includes constructing an F-16 flight simulator facility at Joint Base Andrews for the Air National Guard. The bid response deadline and anticipated award date are not provided in this document.

View the file

Other files for this federal contract opportunity

Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

PROJECT TITLE: F-16 FLIGHT SIMULATOR FACILITY at JOINT BASE ANDREWS, MARYLAND

The purpose of this amendment is to:

1. Provide responses to Requests for Information (RFI)

2. Provide Technical AMD0002 - W912DR22B0004 JBA F-16 MTC - 25 February 2022 Final

3. Provide updated wage determination. New wage determination is MD20220044 dated 25 FEB 2022

All other terms and conditions remain unchanged.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

1. CONTRACT ID CODE PAGE OF PAGES

1 12

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 25-Feb-2022

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912DR22B0004

X 9B. DATED (SEE ITEM 11)

24-Jan-2022

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

25-Feb-2022

CODE

USACE, BALTIMORE

2 HOPKINS PLAZA

BALTIMORE MD 21201

W912DR 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912DR22B0004

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION 00 73 00 - SUPPLEMENTARY CONDITIONS

The following have been modified:

WAGE DETERMINATION

WAGE DETERMINATION DECISION

OF THE SECRETARY OF LABOR

The following wage determination will be used to conform with the requirements of the Davis-Bacon Act (40 U.S.C. 276a to 276a-7) of the Contract Clauses*:

Decision No. MD20220044 dated 2/25/2021

* WAGE DETERMINATIONS: The provisions of the Davis-Bacon Act also apply to employees who work at off-site facilities such as batch plants, rock quarries, sand pits, and the like, which are setup exclusively to furnish material to the on-site construction site. Accordingly, contractors are required to maintain complete records on such employees. However, operations of a “commercial supplies” or “material-man” established in proximity to but not on the actual site of work prior to the opening of bids are not covered by the Act even if dedicated exclusively to the Federal project for a time. (29 CFR 5.2 (1))

General Decision Number: MD20220044 02/25/2022

Superseded General Decision Number: MD20210044

State: Maryland

Construction Type: Building

County: Prince George's County in Maryland.

BUILDING CONSTRUCTION PROJECTS (does not include single family homes or apartments up to and including 4 stories).

Note: Contracts subject to the Davis-Bacon Act are generally required to pay at least the applicable minimum wage rate required under Executive Order 14026 or Executive Order 13658.

Please note that these Executive Orders apply to covered contracts entered into by the federal government that are subject to the Davis-Bacon Act itself, but do not apply to contracts subject only to the Davis-Bacon Related Acts, including those set forth at 29 CFR 5.1(a)(2)-(60).

|If the contract is entered |. Executive Order 14026 | |into on or after January 30, | generally applies to the | |2022, or the contract is | contract. | |renewed or extended (e.g., an |. The contractor must pay | |option is exercised) on or | all covered workers at | |after January 30, 2022: | least $15.00 per hour (or | | | the applicable wage rate | | | listed on this wage | | | determination, if it is | | | higher) for all hours | | | spent performing on the | | | contract in 2022. | |If the contract was awarded on|. Executive Order 13658 | |or between January 1, 2015 and| generally applies to the | |January 29, 2022, and the | contract. | |contract is not renewed or |. The contractor must pay all| |extended on or after January | covered workers at least | |30, 2022: | $11.25 per hour (or the | | | applicable wage rate listed| | | on this wage determination,| | | if it is higher) for all | | | hours spent performing on | | | that contract in 2022. |

The applicable Executive Order minimum wage rate will be adjusted annually. If this contract is covered by one of the Executive Orders and a classification considered necessary for performance of work on the contract does not appear on this wage determination, the contractor must still submit a conformance request.

Additional information on contractor requirements and worker protections under the Executive Orders is available at https://www.dol.gov/agencies/whd/government-contracts.

Modification Number Publication Date

0 01/07/2022 1 01/14/2022 2 02/11/2022 3 02/18/2022 4 02/25/2022

ASBE0024-007 04/01/2021

Rates Fringes

ASBESTOS WORKER/HEAT & FROST

INSULATOR........................$ 39.27 18.67+a

Includes the application of all insulating materials, protective coverings, coatings and finishes to all types of mechanical systems

a. PAID HOLIDAYS: New Year's Day, Martin Luther King Day, Memorial Day, Independence Day, Labor Day, Veterans' Day, Thanksgiving Day,the day after Thanksgiving and Christmas Day provided the employee works the regular work day before and after the paid holiday.

ASBE0024-010 04/01/2021

Rates Fringes

ASBESTOS WORKER: HAZARDOUS

MATERIAL HANDLER (Removal of hazardous material from ceilings, floors, mechanical systems, and walls)..............$ 24.46 8.69+a

a. PAID HOLIDAYS: New Year's Day, Martin Luther King Day, Memorial Day, Independence Day, Labor Day, Veterans' Day, Thanksgiving Day,the day after Thanksgiving and Christmas Day provided the employee works the regular work day before and after the paid holiday.

BRMD0001-006 05/02/2021

Rates Fringes

TILE SETTER......................$ 31.18 12.60

BRMD0001-011 05/02/2021

Rates Fringes

BRICKLAYER (Excluding Pointing, Caulking and Cleaning)........................$ 34.00 12.59

BRMD0001-012 05/02/2021

Rates Fringes

MASON - STONE....................$ 40.81 19.43

BRMD0001-013 05/02/2021

Rates Fringes

TERRAZZO WORKER/SETTER...........$ 31.18 12.60

CARP0197-001 05/01/2021

Rates Fringes

CARPENTER (Including Acoustical Ceiling Installation, Drywall Hanging, Metal Stud Installation and Form Work)......$ 30.34 13.80

CARP0219-001 05/01/2021

Rates Fringes

MILLWRIGHT.......................$ 35.34 13.53

ELEC0026-021 09/07/2020

Rates Fringes

ELECTRICIAN (Communication and Sound Equipment).............$ 29.05 11.39

ELEC0026-022 06/07/2021

Rates Fringes

ELECTRICIAN (Including low voltage wiring for and installation of alarms, HVAC controls)........................$ 49.00 20.26+a a.PAID HOLIDAYS: New Year's Day, Inauguration Day, Martin Luther King Jr.'s Birthday, Memorial Day, Independence Day, Labor Day, Veterans' Day, Thanksgiving Day, the day after Thanksgiving Day and Christmas Day.

ELEV0010-001 01/01/2022

Rates Fringes

ELEVATOR MECHANIC................$ 50.27 36.885+a+b

a. PAID HOLIDAYS: New Year's Day, Memorial Day, Independence Day, Labor Day, Veterans' Day, Thanksgiving Day, Christmas Day and the Friday after Thanksgiving.

b. VACATIONS: Employer contributes 8% of basic hourly rate for 5 years or more of service; 6% of basic hourly rate for 6 months to 5 years of service as vacation pay credit.

ENGI0077-017 05/01/2021

POWER EQUIPMENT OPERATOR:

Backhoe.....................$ 33.36 10.55+a Bulldozer...................$ 33.36 10.55+a

a. PAID HOLIDAYS: New Year's Day, Inaugural Day, Decoration Day, Independence Day, Labor Day, Martin Luther King's Birthday, Veterans' Day, Thanksgiving Day, Friday after Thanksgiving and Christmas Day.

IRON0005-005 06/01/2021

Rates Fringes

IRONWORKER, STRUCTURAL AND

ORNAMENTAL.......................$ 33.90 24.19

IRON0005-014 05/01/2021

Rates Fringes

IRONWORKER, REINFORCING..........$ 29.20 22.83

LABO0011-016 06/15/2020

Rates Fringes

LABORER (Common or General)......$ 17.77 8.63 LABORER: Mason Tender - Cement/Concrete..................$ 25.88 8.63 LABORER: Pipelayer..............$ 25.88 8.63

PAIN0051-014 06/01/2021

Rates Fringes

GLAZIER

Glazing Contracts $2 million and under...........$ 29.02 12.80 Glazing Contracts over $2 million.....................$ 33.26 12.80

PAIN0051-019 06/01/2021

Rates Fringes

PAINTER

Brush, Roller, Spray and Drywall Finisher/Taper......$ 25.50 11.27 Industrial..................$ 32.70 13.18

PLAS0891-005 07/01/2021

Rates Fringes

PLASTERER........................$ 30.53 7.93

PLAS0891-006 02/01/2020

CEMENT MASON/CONCRETE FINISHER...$ 28.82 11.68

PLAS0891-008 08/01/2016

Rates Fringes

PLASTERER (Fireproofing Including Sprayer, Mixer, and Handler) Handler.....................$ 16.50 4.89 Mixer/Pump..................$ 18.50 4.89 Sprayer.....................$ 23.00 4.89

PLUM0005-010 08/01/2021

Rates Fringes

PLUMBER..........................$ 45.92 20.35+a

a. PAID HOLIDAYS: Labor Day, Veterans' Day, Thanksgiving Day and the day after Thanksgiving, Christmas Day, New Year's Day, Martin Luther King's Birthday, Memorial Day and the Fourth of July.

PLUM0602-011 08/01/2021

Rates Fringes

PIPEFITTER (Including HVAC Pipe and System Installation)....$ 45.39 23.12+a

a. PAID HOLIDAYS: New Year's Day, Martin Luther King's Birthday, Memorial Day, Independence Day, Labor Day, Veterans' Day, Thanksgiving Day and the day after Thanksgiving and Christmas Day.

ROOF0030-016 07/01/2021

Rates Fringes

ROOFER...........................$ 31.26 14.56

SFMD0669-001 01/01/2022

Rates Fringes

SPRINKLER FITTER (Fire Sprinklers)......................$ 36.95 24.56

SHEE0100-015 11/01/2021

Rates Fringes

SHEET METAL WORKER (Including HVAC Duct Installation)..........$ 44.37 21.33+a

a. PAID HOLIDAYS: New Year's Day, Martin Luther King's Birthday, Memorial Day, Independence Day, Labor Day, Veterans Day, Thanksgiving Day and Christmas Day

* SUMD2010-092 08/04/2010

LABORER

Grade Checker...............$ 16.00 2.90 Landscape...................$ 9.23 ** 0.00 Mason Tender - Brick........$ 13.28 ** 2.95 Mason Tender - Stone........$ 14.03 ** 0.00 Mason Tender for Pointing, Caulking and Cleaning.......$ 14.15 ** 0.00 Mortar Mixer................$ 16.61 9.08

POINTER, CAULKER, CLEANER,

Includes pointing, caulking, cleaning of existing masonry, brick, stone and cement structures (restoration work); excludes pointing, caulking, cleaning of new or replacement masonry, brick, stone or cement...........................$ 19.14

POWER EQUIPMENT OPERATOR:

Asphalt Roller..............$ 21.35 5.38 Bobcat/Skid Loader..........$ 18.05 8.78 Boom........................$ 21.44 8.29 Crane.......................$ 20.95 6.18 Excavator...................$ 20.00 0.00 Forklift....................$ 16.00 5.12 Gradall.....................$ 20.50 8.42 Grader/Blade................$ 14.50 ** 5.18 Loader......................$ 24.00 5.40 Paver.......................$ 17.47 6.36 Roller excluding Asphalt....$ 17.60 3.88

TILE FINISHER....................$ 17.87 7.32

TRUCK DRIVER

Dump Truck..................$ 15.90 1.12 Tractor Haul Truck..........$ 17.87 9.98

WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental.

** Workers in this classification may be entitled to a higher minimum wage under Executive Order 14026 ($15.00) or 13658 ($11.25). Please see the Note at the top of the wage determination for more information.

Note: Executive Order (EO) 13706, Establishing Paid Sick Leave for Federal Contractors applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2017. If this contract is covered by the EO, the contractor must provide employees with 1 hour of paid sick leave for every 30 hours they work, up to 56 hours of paid sick leave each year.

Employees must be permitted to use paid sick leave for their own illness, injury or other health-related needs, including preventive care; to assist a family member (or person who is like family to the employee) who is ill, injured, or has other health-related needs, including preventive care; or for reasons resulting from, or to assist a family member (or person who is like family to the employee) who is a victim of, domestic violence, sexual assault, or stalking. Additional information on contractor requirements and worker protections under the EO is available at https://www.dol.gov/agencies/whd/government-contracts.

Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)).

The body of each wage determination lists the classification and wage rates that have been found to be prevailing for the cited type(s) of construction in the area covered by the wage determination. The classifications are listed in alphabetical order of ""identifiers"" that indicate whether the particular rate is a union rate (current union negotiated rate for local), a survey rate (weighted average rate) or a union average rate (weighted union average rate).

Union Rate Identifiers

A four letter classification abbreviation identifier enclosed in dotted lines beginning with characters other than ""SU"" or ""UAVG"" denotes that the union classification and rate were prevailing for that classification in the survey. Example:

PLUM0198-005 07/01/2014. PLUM is an abbreviation identifier of the union which prevailed in the survey for this classification, which in this example would be Plumbers. 0198 indicates the local union number or district council number where applicable, i.e., Plumbers Local 0198. The next number, 005 in the example, is an internal number used in processing the wage determination. 07/01/2014 is the effective date of the most current negotiated rate, which in this example is July 1, 2014.

Union prevailing wage rates are updated to reflect all rate changes in the collective bargaining agreement (CBA) governing this classification and rate.

Survey Rate Identifiers

Classifications listed under the ""SU"" identifier indicate that no one rate prevailed for this classification in the survey and the published rate is derived by computing a weighted average rate based on all the rates reported in the survey for that classification. As this weighted average rate includes all rates reported in the survey, it may include both union and non-union rates. Example: SULA2012-007 5/13/2014. SU indicates the rates are survey rates based on a weighted average calculation of rates and are not majority rates. LA indicates the State of Louisiana. 2012 is the year of survey on which these classifications and rates are based. The next number, 007 in the example, is an internal number used in producing the wage determination. 5/13/2014 indicates the survey completion date for the classifications and rates under that identifier.

Survey wage rates are not updated and remain in effect until a new survey is conducted.

Union Average Rate Identifiers

Classification(s) listed under the UAVG identifier indicate that no single majority rate prevailed for those classifications; however, 100% of the data reported for the classifications was union data. EXAMPLE: UAVG-OH-0010 08/29/2014. UAVG indicates that the rate is a weighted union average rate. OH indicates the state. The next number, 0010 in the example, is an internal number used in producing the wage determination. 08/29/2014 indicates the survey completion date for the classifications and rates under that identifier.

A UAVG rate will be updated once a year, usually in January of each year, to reflect a weighted average of the current negotiated/CBA rate of the union locals from which the rate is based.

WAGE DETERMINATION APPEALS PROCESS

1.) Has there been an initial decision in the matter? This can be:

* an existing published wage determination

* a survey underlying a wage determination

* a Wage and Hour Division letter setting forth a position on a wage determination matter

* a conformance (additional classification and rate) ruling

On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour National Office because National Office has responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.) and 3.) should be followed.

With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to:

Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator (See 29 CFR Part 1.8 and 29 CFR Part 7). Write to:

Wage and Hour Administrator

U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue.

3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to:

Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

4.) All decisions by the Administrative Review Board are final.

END OF GENERAL DECISION

(End of Summary of Changes)

AMENDMENT NO. 0002 TO W912DR22B0004

F-16 FLIGHT SIMULATOR FACILITY at JOINT BASE ANDREWS, MD

EFFECTIVE 25 FEBRUARY 2022

SOLICITATION:

1) Attachment E: Delete this attachment entirely.

2) Price Schedule: Delete this document and replace with the attached revised price schedule, dated 22 February 2022.

SPECIFICATIONS:

3) Specification 08 71 00: Add Attachment HARDWARE SCHEDULE, dated February 22, 2022, to the end of the specification.

4) Specification 09 06 00: Delete this specification as originally issued and substitute the attached like-named specification, dated February 22, 2022.

5) Specification 28 10 05, paragraph 2.7.1: Revise second paragraph, third sentence to read the following:

"Size battery to sustain the UPS at full rated load for 24 hours until the diesel engine generator set can assume the load."

DRAWINGS:

6) Sheet C600: Delete this sheet in its entirety as originally issued and substitute the attached like-numbered sheet, dated February 22, 2022.

7) Sheet FCP-1: Delete this sheet in its entirety as originally issued and substitute

8) Sheet AE101: Delete this sheet in its entirety as originally issued and substitute

9) Sheet AE401: Delete this sheet in its entirety as originally issued and substitute

10) Sheet AE601: Delete this sheet in its entirety as originally issued and substitute

11) Sheet IN101: Delete this sheet in its entirety as originally issued and substitute

AMENDMENT NO. 0002 TO W912DR22B0004

F-16 FLIGHT SIMULATOR FACILITY at JOINT BASE ANDREWS, MD

EFFECTIVE 25 FEBRUARY 2022

12) Sheet F-001: Add the following note to read the following:

“11. FOR STC (SOUND TRANSMISSION COEFFICIENT) RATED WALLS:

DO NOT ROUTE CONDUIT INSIDE STC RATED WALLS. PROVIDE

SURFACE MOUNTED CONDUIT AND BOXES, PAINTED TO MATCH WALL

WHEN CONNECTED TO WALL, MOUNTED PANELS OR DEVICES.

PROVIDE PERMANENT LABELS ON EXTERIOR OF BOXES AND

DEVICES MOUNTED ON WALL.”

GENERAL:

13) Attached For Information Only:

“Geotechnical Recommendations Report”

“Phase I ESA Report”

PART I PRICE SCHEDULE

SECTION 00010 - SUPPLIES OR SERVICES AND PRICES

00010-1

W912DR-22-B-0004

UNIT PRICE SCHEDULE

REVISED 2/22/2022

Item Estimated No. Description Quantity Unit Price Amount

0001 All costs in connection with construction of the F- 16 Mission Training Center at Joint Base Andrews, including utilities to points 5 feet outside the building lines, complete as shown on drawings and specified, exclusive of optional bid items below.

JOB

0002 All costs in connection with construction of all outside utilities beyond points 5 feet outside the building lines and all site work for the F-16 Mission Training Center at Joint Base Andrews, complete as shown on drawings and specified, exclusive of optional bid items below.

0003 Payment to ASUS(Terrapin Utility Services, Inc.)

for Utility work

$_338,704.00

TOTAL ESTIMATED BASE BID AMOUNT: $ ____________

00010-2

OPTIONAL BID ITEMS

Item Estimated No. Description Quantity Unit Price Amount

All costs in connection with the construction of masonry walls with decorative gate in the Mechanical Yard, complete as shown on drawings and specified.

All cost in connection with the construction of illuminated insignia sign, complete as shown on drawings and specified.

with the construction of 2” stone at Mechanical Yard, All cost in connection with the construction of the roof hatch and ladder, the vertical monolith building entry panel, the additional brick veneer masonry, complete as shown on drawings and specified.

00010-3 with construction of HMA driveway pavements and associated curb cuts, with construction of interior flooring finishes (identified as OLI #8), with construction of building interior signage, TOTAL ESTIMATED OPTIONAL AND BASE BID AMOUNT $ _______________

NOTES TO BIDDERS

Offerors must quote on all items. Failure to quote on all items may be cause for rejection of the proposal.

Optional Items may be exercised at any time within 90 calendar days after the date of receipt of Notice to Proceed. The Contracting Officer may exercise the Optional Items by written notice to the Contractor, postmarked within the period specified above. The Government may exercise any, all or none of the listed Optional Items in any order.

No additional time for contract completion will be allowed when an Optional Item is exercised.

Evaluation of Options:

Except when it is determined not to be in the Government’s best interests, the Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. Evaluation of options will not obligate the Government to exercise the option(s).

NGBJV/DC-F-16 MISSION TRAINING CENTER (MTC)

DC ANG BASE – JOINT BASE ANDREWS

DC ANG PN: AJFX 189013

FEBRUARY 22, 2022 - AMENDMENT #2

ADDNE

DOOR HARDWARE

087100 - 1

HARDWARE SCHEDULE

For the following Door Hardware Schedule items, other than the required sole-source hardware by Best Locke per the approved J&A, the Contractor may provide an approved equal substitute during the submittal process. This provision requires that for each product, the Contractor is responsible for submitting and demonstrating that the product submitted meets or exceeds the salient characteristics of the contract documents, including any listed basis of design product, in terms of all physical, functional, performance, quality and aesthetic characteristics. Furthermore, the Contractor is responsible for submitting and demonstrating the product submitted is fully compatible with the project and its intended use and function. The Contractor shall also clearly identify the submittal product by brand name and make/model number and shall include all applicable descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information made available to the Contracting Officer.

Hardware Group No. 101

For use on mark/door #(s): 103A

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA OFFICE/ENTRY LOCK L9050T 06A L583-363 626 SCH

1 EA PRIMUS CORE 20-740 EV C PERMANENT CORE 626 SCH

1 EA SURFACE CLOSER

KEYED AS DIRECTED BY OWNER

4040XP SCUSH X MTG BRKT, SPCR & 689 LCN

1 EA KICK PLATE

PLATE AS REQ X ST3596

8400 10" X 2" LDW B-CS 630 IVE

1 EA GASKETING 188S-BK (AT RATED OR USE

SILENCERS)

BK ZER

Hardware Group No. 201C

For use on mark/door #(s): 109A

1 EA STOREROOM LOCK L9080T 06A 626 SCH

4040XP SCUSH X MTG BRKT, SPCR& 689 LCN

087100 - 2

Hardware Group No. 203G

For use on mark/door #(s): 107A, 113A

Hardware Group No. 203P

For use on mark/door #(s): 116A

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 EA CYPHER LOCK L1021B 626 SIM

1 EA PERMANENT CORE KEYED TO MATCH EXISTING KEY BES

SYSTEM

4040XP SCUSH X MTG BRKT, SPCR& 689 LCN

1 EA PROTECTION PLATE

8400 10" X 1" LDW B-CS 629 IVE

1 EA RAIN DRIP 142A DW + 4" A ZER

1 EA GASKETING SET 328AA -S A ZER

1 EA DOOR SWEEP 8198AA A ZER

1 EA THRESHOLD 566A A ZER

1 EA DOOR CONTACT BY ANOTHER SECTION WHT

1 EA STOREROOM LOCK L9080T 06A 626 SCH

1 EA WALL STOP

WS406/407CCV 625 IVE

1 EA DOOR BOTTOM 320AA A ZER

1 EA THRESHOLD 655A -223 A ZER

1 EA GASKETING 188S H & J BK ZER

087100 - 3

Hardware Group No. 204

For use on mark/door #(s): 115A

Provide each PR door(s) with the following:

6 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

2 EA MANUAL FLUSH BOLT FB358 OR FB458 - TYPE AS REQ 626 IVE

1 EA DUST PROOF STRIKE DP1 OR DP2 - TYPE AS REQ 626 IVE

1 EA CYPHER LOCK L1021B 626 SIM

1 EA PERMANENT CORE KEYED TO MATCH EXISTING KEY BES

1 EA OH STOP

100S - SIZE AS REQ 630 GLY

1 EA SURFACE CLOSER 4040XP SCUSH X MTG BRKT, SPCR& 689 LCN

2 EA PROTECTION PLATE

1 EA ASTRAGAL 328AA (2 PCS - 1 SET) HEIGHT AS

REQUIRED

2 EA DOOR SWEEP 8198AA

AL ZER

3 EA DOOR SWEEP 8198AA A ZER

087100 - 4

Hardware Group No. 341

For use on mark/door #(s): 108A

1 EA PRIVACY W/DB & IND L9496T 06A L583-363 L283-722 626 SCH

4040XP OR P4040XP X MTG BRKT, 689 LCN

SPCR & PLATE AS REQ X ST3596

1 EA WALL STOP WS406/407CCV 625 IVE

Hardware Group No. 724

For use on mark/door #(s): 117A

6 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA POWER TRANSFER EPT10 CON 689 VON

2 EA MANUAL FLUSH BOLT FB358 OR FB458 - TYPE AS REQ 626 IVE

1 EA DUST PROOF STRIKE DP1 OR DP2 - TYPE AS REQ 626 IVE

1 EA PANIC DEVICE LD-99-EO 626 VON

1 EA CYPHER LOCK LP1020B 626 SIM

EA PRIMUS MORT. CYL. 20-700 626 SCH

2 EA SURFACE CLOSER

4040XP SHCUSH X MTG BRKT, SPCR 689 LCN

& PLATE AS REQ X ST3596

2 EA DOOR SWEEP 8198AA A ZER

EA

HARNESS (IN DOOR)

HARNESS (TO POWER

ALLEGION CONNECT TYPE &

LENGTH AS REQ

CON-6W

VON

1 EA

SUPPLY)

POWER SUPPLY PS902 900-2RS LGR VON

CREDENTIAL

READER/KEYPAD

POWER SUPPLY

CARD READER/KEYPAD TO BE

PROVIDED BY ANOTHER SECTION

POWER SUPPLY FOR CARD READER

BY ANOTHER SECTION

087100 - 5

Hardware Group No. 724WT

For use on mark/door #(s): 118B, 124B, 126B, 130B

-No Ingress- exit only.

-Egress by the push pad on active leaf which releases both mag locks.

-Push button releases mag lock for exit if power fails.

HINGE

POWER TRANSFER

BY STC DOOR/FRAME

MANUFACTURER

EPT10 CON - ACTIVE LEAF

689 VON

2 EA MANUAL FLUSH BOLT FB358 OR FB458 - TYPE AS REQ W/ 30” 626 IVE

1 EA DUST PROOF STRIKE

TOP BOLT

DP1 OR DP2 - TYPE AS REQ 626 IVE

1 EA ELEC EXIT RX-LD-99-EO 626 VON

HARDWARE

1 EA MAGNETIC LOCK 1120 X MTG BRKT & VOLTAGE AS 626 DOR

REQ T

1 EA PUSH BUTTON 621AL-DA 630 LOC

2 EA SURFACE CLOSER 4040XP SHCUSH X MTG BRKT, SPCR 689 LCN

SOUND SEAL

DOOR SWEEP

8198AA

A

A ZER

AUTO-DOOR BOTTOM

THRESHOLD

RABBETED THRESHOLD BY STC

1 EA DOOR CONTACT

DOOR/FRAME MFR. (EQ TO ZERO

#566A)

BY ANOTHER SECTION WHT

1 EA POWER SUPPLY PS902 900-2RS GR VON

1 EA HARNESS (IN DOOR) ALLEGION CONNECT TYPE &

087100 - 6

For use on mark/door #(s): 125A

ELEC EXIT

RX-LD-99-EO LENGTH AS REQ

626 VON

MAGNETIC LOCK 1110 X MTG BRKT & VOLTAGE AS 626 DORT

1 EA PUSH BUTTON

REQ

621AL-DA 630 LOC

1 EA SURFACE CLOSER 4040XP SCUSH X MTG BRKT, SPCR 689 LCN

SOUND SEAL

DOOR SWEEP

8198AA

AUTO-DOOR

BOTTOM

RABBETED THRESHOLD BY STC

1 EA DOOR CONTACT

DOOR/FRAME MFR. (EQ TO ZERO

#566A)

BY ANOTHER SECTION WHT

1 EA POWER SUPPLY PS902 900-2RS GR VON

1 EA HARNESS (IN DOOR) ALLEGION CONNECT TYPE &

-No Ingress- exit only.

-Egress by the push pad which releases mag lock.

-Push button releases mag lock for exit if power fails.

Hardware Group No. 800ATV

For use on mark/door #(s): 101B

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DUMMY PUSH BAR 350 LENGTH AS REQUIRED 626 VON

1 EA 90 DEG OFFSET 8190-O 10" 630 IVE

PULL

1 EA SURFACE CLOSER 4040XP SCUSH X MTG BRKT, SPCR 689 LCN

& PLATE AS REQ

087100 - 7

Hardware Group No. 801

For use on mark/door #(s): 106A

1 EA PUSH PLATE 8200 4" X 16" 626 IVE

1 EA PULL PLATE 8302 10" 4" X 16" 630 IVE

1 EA SURFACE CLOSER 4040XP OR P4040XP X MTG BRKT, 689 LCN

1 EA WALL STOP WS406/407CCV 630 IVE

1 SET SEALS 188S H & J (USE SILENCERS @ NON-

RATED/NON-SMOKE DOORS)

BLK ZER

Hardware Group No. C200CG

For use on mark/door #(s): 119A, 123A, 129A

EPT10 CON

2 EA MANUAL FLUSH BOLT FB358 OR FB458 - TYPE AS REQ 626 IVE

1 EA DUST PROOF STRIKE DP1 OR DP2 - TYPE AS REQ 626 IVE

1 EA EU MORTISE LOCK L9092TEU 06A RX CON 12/24 VDC 626 SCH

1 EA SURFACE CLOSER 4040XP SCUSH X MTG BRKT, SPCR & 689 LCN

2 EA MAGNETIC LOCK

1120 X MTG BRKT & VOLTAGE AS 626 DORT

ASTRAGAL

1 EA THRESHOLD

BY STC DOOR/FRAME A

1 EA SOUND SEAL

BY STC DOOR/FRAME BK

1 EA HARNESS (IN DOOR)

ALLEGION CONNECT TYPE & VON

1 EA HARNESS (TO POWER

CON-6W VON

2 EA DOOR CONTACT BY ANOTHER SECTION WHT

087100 - 8

1 EA CREDENTIAL

1 EA POWER SUPPLY POWER SUPPLY FOR CARD READER

-Ingress by the access control to unlock the mortise lock, release the magnetic lock and shunt the alarm or key override to unlock the mortise lock in case of power failure.

-Egress by the lever, which will release the mag lock (RX feature) and shunt the alarm.

-Push button releases mag lock if power fails.

Hardware Group No. C201

For use on mark/door #(s): 121A

1 EA MAGNETIC LOCK

1110 X MTG BRKT & VOLTAGE AS 626 DORT

320AABY STC DOOR/FRAME

655A -223320AABY STC

1 SET SOUND SEALS

DOOR/FRAME MANUFACTURER

BY STC DOOR/FRAME BLK

1 EA HARNESS (IN DOOR) ALLEGION CONNECT TYPE & VON

1 EA DOOR CONTACT BY ANOTHER SECTION WHT SCE

1 EA CREDENTIAL CARD READER/KEYPAD TO BE

READER/KEYPAD PROVIDED BY ANOTHER

SECTION

1 EA POWER SUPPLY POWER SUPPLY FOR CARD

READER BY ANOTHER SECTION

-Ingress by the access control to unlock the mortise lock, release the magnetic lock and shunt the alarm or

-Egress by the lever, which will release the mag lock and shunt the alarm.

087100 - 9

Hardware Group No. C201GX

For use on mark/door #(s): 111A, 114A

-Ingress by the access control to unlock the Integrated Lock System, release the magnetic lock and shunt the alarm.

INTEGRATED LOCK

CYLINDRICAL LOCK

DKXL-10 TYPE IV (CDX-10 LINKED

TO CYL LOCK)

93K X REQUIRED FUNCTION

KAB

BES

1 EA PRIMUS CORE KEYED AS DIRECTED BY OWNER 626 SCH

1 EA MAGNETIC LOCK 1110 X MTG BRKT & VOLTAGE AS 626 DORT

WS406/407CCV 630 IVE

1 EA DOOR CONTACT Y ANOTHER SECTION WHT

087100 - 10

Hardware Group No. C717RT

For use on mark/door #(s): 101A

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA POWER TRANSFER EPT10 689 VON

1 EA ELEC EXIT RX-QEL-99-NL LENGTH AS REQ 626 VON

1 EA PRIMUS RIM 20-710-XP EV C X KEYED CONST 626 SCH

CYLINDER CORE

1 EA 90 DEG OFFSET PULL 8190-O 10" 630 IVE

1 EA SURFACE CLOSER 4040XP SCUSH X MTG BRKT, SPCR 689 LCN

1 EA DOOR SWEEP 8198AA A ZER

1 EA HARNESS (IN DOOR) ALLEGION CONNECT TYPE VON

& LENGTH AS REQ

Ingress by the card reader or key override. Egress by the push pad.

Hardware Group No. CE711A

For use on mark/door #(s): 112A, 112B

PANIC HARDWARE

99-L-BE

626 VON

1 EA POWER TRANSFER EPT-5 628 PRE

INTEGRATED LOCK

PANIC DEVICE

DKX-10 TYPE IV (CDX-10 LINKED TO

PANIC DEVICE)

F9300 X REQUIRED FUNCTION

KAB

DORM

1 EA PRIMUS RIM 20-710-XP EV C X KEYED CONST 626 SCH

CYLINDER

PRIMUS CORE

CORE

20-740 EV C PERMANENT CORE 626 SCH

1 EA MAGNETIC LOCK 1110 X MTG BRKT & VOLTAGE AS 626 DORT

087100 - 11

SURFACE CLOSER

WALL STOP

4040XP OR P4040XP X MTG BRKT,

WS406/407CCV

LCN

IVE

AUTO-DOOR

BOTTOM

1 SET SOUND SEAL

HARNESS (TO POWER

CON-192P

PS902 900-2RS LGR

SCH

1 EA CREDENTIAL

1 EA POWER SUPPLY POWER SUPPLY FOR CARD READER

-Ingress by the access control to unlock the Integrated Lock System, release the magnetic lock and shunt the alarm.

-Egress by the push padCE, which will release the mag lock and shunt the alarm.

Hardware Group No. CK201G

For use on mark/door #(s): 120A, 122A, 128A

3 EA HINGE BY STC DOOR/FRAME 652 IVE

1 EA POWER TRANSFER

EPT10 CON 689 VON

4040XP OR P4040XP X MTG BRKT, 689 LCN

1 EA MAGNETIC LOCK

1110 X MTG BRKT & VOLTAGE AS 626 DOR

1 EA WALL STOP WS406/407CCV 630 IVE

087100 - 12

1 EA POWER SUPPLY PS902 900-2RS LGR VON

CREDENTIAL

POWER SUPPLY FOR CARD

-Ingress by the access control to unlock the mortise lock, release the magnetic lock and shunt the alarm or

Hardware Group No. CK201GW

For use on mark/door #(s): 118A, 124A, 126A, 127A, 130A

-Ingress by the access control to unlock the mortise lock, release the magnetic lock and shunt the alarm or

1 EA MAGNETIC LOCK 1110 X MTG BRKT & VOLTAGE AS 626 DOR

WS406/407CCV 630 IVE

1 EA DOOR CONTACT BY ANOTHER SECTION WHT SCE

1 EA CREDENTIAL BY ANOTHER SECTION

087100 - 13

END OF SECTION 08 7100

NGBJV - FLIGHT SIMULATOR AJXF 189013

JOINT BASE ANDREWS FEBRUARY 22, 2022 - AMENDMENT #2

SECTION 09 06 00

SCHEDULES FOR FINISHES

05/09

PART 1 GENERAL

1.1 SUMMARY

This section covers only the color of exterior and interior materials and products that are exposed to view in the finished construction. The word "color", as used herein, includes surface color and pattern. Requirements for quality, product specifications, and method of installation are covered in other appropriate sections of the specifications. Specific locations where the various materials are required are shown on the drawings if not identified in this specification. Items not designated for color in this section may be specified in other sections. When color is not designated for items, propose a color for approval.

PART 2 PRODUCTS

2.1 COLOR SCHEDULE

The color schedule information provided in the following paragraphs lists the colors, patterns and textures required for exterior and interior finishes, including both factory applied and field applied colors. Where color is shown as being specific to one manufacturer, an equivalent color by another manufacturer may be submitted for approval. Manufacturers and materials specified are not intended to limit the selection of equal colors from other manufacturers. In the case of difference between the drawings and specifications, colors identified in this specification govern.

2.2 EXTERIOR FINISHES

2.2.1 Exterior Walls

Exterior wall colors apply to exterior wall surfaces including recesses at entrances and projecting vestibules. When applicable, paint conduit to closely match the adjacent surface color. Provide wall colors to match the colors listed below.

2.2.1.1 Brick

MV1: Modular Brick Masonry Veneer, Color and texture to match:

Carolina Chestnut Blend

2.2.1.2 Mortar

Grey

2.2.1.3 Metal Wall Panels, Hardware, and Associated Trim

FWP1: Centria, Color to match: 9910 Light Seawolf

FWP2: Centria, Color to match: 154 Dark Bronze

SECTION 09 06 00 Page 1

2.2.1.4 Glass and Glazing

PPG Solarban z50 (2) Optiblue + Clear Glass Insulating Glass Unit

2.2.2 Exterior Trim

Provide exterior trim to match the colors listed below.

2.2.2.1 Steel Doors and Door Frames (Painted)

PT6: Sherwin Williams, SW7048 Urbane Bronze, Semi Gloss; Basis of Design

2.2.2.2 Aluminum Doors and Door Frames

Anodized, Clear 14

2.2.2.3 Downspouts and Gutters

Color to Match: FWP1

2.2.2.4 Manufactured Canopy

Mapes: Color to Match: Mapes Bronze

2.2.2.5 Louvers

Match adjacent material in color.

2.2.2.6 Flashings

2.2.2.7 Caulking and Sealants

2.2.2.8 Bollards

Paint to match FPW2; provide safety yellow tape at top of bollard.

2.2.2.9 Control Joints

2.2.3 Exterior Roof

Apply roof color to exterior roof surfaces including sheet metal flashings and copings, snow guards, mechanical units, mechanical penthouses, roof trim, pipes, conduits, electrical appurtenances, and similar items.

Provide roof color to match the colors listed below.

2.2.3.1 Metal

Color to Match: Federal Stanadrd 595, Color Number 30475, Saudi Brown #11

SECTION 09 06 00 Page 2

2.2.3.2 Penetrations

Match roof in color.

2.3 INTERIOR FINISHES

2.3.1 Interior Floor Finishes

Provide flooring materials to match the colors listed below.

2.3.1.1 Carpet Tile

CPT1: Mohawk Group - Sector Tile BT285 / Shale 7927, 24" x 24", Vertical Ashlar Installation; Basis of Design

CPT2: Interface - PosiTile Staticworx ShadowFX Treez / Willow, 24" x 24"; Basis of Design

2.3.1.2 Vinyl Composition Tile

VCT1: Armstrong - Standard Excelon Imperial Texture / Field Grey 51927, 12" x 12"; Basis of Design

2.3.1.3 Luxury Vinyl Tile

LVT1: Tarkett - Contour Series, Modern Stone Tile / PCCN 0712 QU Soapstone, 24" x 24"; Basis of Design

2.3.1.4 Static-Control Resilient Flooring (Static-Dissipative Vinyl Tile)

SDT1: VPI - Conductile, 16 Cloud, 12" x 12"; Basis of Design

2.3.1.5 Porcelain Tile

PRC1: Crossville - Argent / Clean Slate A1417, 6" x 6"; Basis of

2.3.1.6 Grout

GRT1: Mapei - Ultracolor Plus FA / 47 Charcoal; Basis of Design

2.3.1.7 Transition Strips

Resilient: Johnsonite - 29 Moon Rock; Basis of Design Aluminum: Schluter - Clear Anodized; Basis of Design

2.3.1.8 Walk-Off Carpet Tile

WOC1: Milliken - Obex Tile / Cutx / Fizz / Grey FZC27173, 19.7" x 19.7"; Basis of Design

2.3.1.9 Concrete

CONC1: Liquid Applied Penetrating Concrete Hardening Treatment

CONC1 (where scheduled at Access Flooring): Tate - ConCore Access Panels / Classic Concrete Finish; Basis of Design

SECTION 09 06 00 Page 3

2.3.1.10 Epoxy Resinous Flooring

ERF1: Stonhard - Stonclad ESD / Cool Shale with #2 Texture; Basis of Design

2.3.2 Interior Base Finishes

Provide base materials to match the colors listed below.

2.3.2.1 Resilient Base and Moldings

RB1: Tarkett - Traditional Vinyl Base / 29 Moon Rock / 4" tall, 1/8" thick, with cove; Basis of Design

2.3.2.2 Porcelain Tile

PRCB1: Crossville - Argent / Clean Slate A1417, 6" x 12" Cove Base; Basis of Design

2.3.2.3 Grout

GR1: Mapei - Ultracolor Plus FA / 47 Charcoal; Basis of Design

2.3.3 Interior Wall Finishes

Apply interior wall color to the entire wall surface, including reveals, vertical furred spaces and columns, grilles, diffusers, electrical and access panels, and piping and conduit adjacent to wall surfaces unless otherwise specified. Paint items not specified in other paragraphs to match adjacent wall surface. Provide wall materials to match the colors listed below.

2.3.3.1 Paint

PT1: Sherwin Williams, SW7008 Alabaster, Eggshell; Basis of Design

PT2: Not used.

PT4: Sherwin Williams, SW7005 Pure White, Semi Gloss; Basis of

2.3.3.2 Porcelain Tile

PRC1: Crossville - Argent / Clean Slate A1417, 6" x 6"; Basis of

PRC2: Crossville - Argent / On The Rocks A1420, 6" x 24"; Basis of

2.3.3.3 Grout

GR1: Mapei - Ultracolor Plus FA / 47 Charcoal; Basis of Design

2.3.3.4 Exposed Structural Columns

Match scheduled paint of adjacent wall.

SECTION 09 06 00 Page 4

2.3.4 Interior Ceiling Finishes

Apply ceiling colors to ceiling surfaces including soffits, furred down areas, grilles, diffusers, registers, and access panels. In addition, apply ceiling color to joists, underside of roof deck, and conduit and piping where joists and deck are exposed and required to be painted.

Provide ceiling materials to match the colors listed below.

2.3.4.1 Acoustical Ceiling Panels and Grid

ACP1: Armstrong Commercial Ceilings - Ultima / Beveled Tegular Edge, White, 24" x 24"; Basis of Design

ACP1 Grid: Armstrong Commercial Ceilings - Interlude XL / Factory White, Tee Grid, 9/16"; Basis of Design

2.3.4.2 Paint (Ceilings)

PT3: Sherwin Williams, SW7007 Ceiling Bright White, Flat; Basis of

2.3.4.3 Exposed Metal Deck

2.3.4.4 Exposed Structural Framing

2.3.5 Interior Trim

Provide interior trim to match the colors listed below.

2.3.5.1 Steel Doors

PT5: Sherwin Williams, SW7019 Gauntlet Gray, Semi Gloss; Basis of

2.3.5.2 Steel Door Frames

PT5: Sherwin Williams, SW7019 Gauntlet Gray, Semi Gloss; Basis of

2.3.5.3 Wood Doors

Solid Core White Birch Pre-Finished Wood Door (Rotary Cut) with Clear finish coat

2.3.5.4 Fire Extinguisher Cabinets

White

2.3.6 Interior Window Treatment

Provide window treatments to match the colors listed below.

SECTION 09 06 00 Page 5

2.3.6.1 Window Shades

RS1: Mecho Shade Systems - EcoVeil Screens / 1369 Silver Birch, Visible Light Transmittance 15%, Manual Operation; Basis of Design

2.3.7 Interior Miscellaneous

Provide miscellaneous items to match the colors listed below.

2.3.7.1 Toilet Accessories

Stainless Steel

2.3.7.2 Toilet Partitions and Urinal Screens

Scranton - Hiny Hiders / Texture Orange Peel, Color Charcoal Grey;

Basis of Design

2.3.7.3 Access Panels

Architect to match adjacent surface using manufacturer's full range of finishes.

2.3.7.4 Plastic Laminate

PLAM1: Wilsonart - 10776-60 Kensington Maple; Basis of Design

2.3.7.5 Solid Surfacing Material

SSM1: Corian - Deep Mink; Basis of Design

2.3.7.6 Corner Guards

CG1: Acrovyn - CO-8 / Stainless Steel, 3 1/2" Legs x 48" Height;

2.3.7.7 Protective Wall Covering/Panel

FRP1: Marlite, FRP Class A, P100 White; Basis of Design

2.3.7.8 Signage Message Color

SG1: Signsations - Black; Basis of Design

2.3.7.9 Signage Background Color

SG2: Signsations - Custom / Mathews Painted Brushed Aluminum;

2.3.7.10 Wall Switch Handles and Standard Receptacle Bodies

White Switches & Bodies

2.3.7.11 Electrical Device Cover Plates

White

SECTION 09 06 00 Page 6

2.3.7.12 Electrical Panels

Paint to match adjacent surface.

PART 3 EXECUTION

Not Used

-- End of Section --

SECTION 09 06 00 Page 7

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

20182890

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

FEBRUARY 22, 2022

JAC

EAN

215 SCHILLING CIRCLE

SUITE 102

HUNT VALLEY, MD 21031

410-785-7423 PHONE 410-771-1313 FAX

PROFESSIONAL CERTIFICATION

I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR

APPROVED BY ME, AND THAT I AM A DULY LICENSED PROFESSIONAL

ENGINEER UNDER THE LAWS OF THE STATE OF MARYLAND,

LICENSE NO. 14446 , EXPIRATION DATE 05-25-23 .

FDN

J o i n t a s e d r w m p

S g

M y l c f u b

N G h

W

F s

T r

ESC PLAN

C600

PROPOSED

F-16 MISSION TRAINING CENTER (MTC)

JOINT BASE ANDREWS, MD

EROSION AND SEDIMENT CONTROL PLANS

MDE No. 20-SF-0173

1 Amendment 0002 02-22-2022

AutoCAD SHX Text

02/22/22

R

O

E

L

P

I

Y

U

H

A.

O.

STANDARD STABILIZATION NOTE:

*STABILIZATION PRACTICES ON ALL PROJECTS MUST BE IN COMPLIANCE WITH THE REQUIREMENTS OF COMAR 26.17.1.08 G REGULATIONS. FOLLOWING INITIAL SOIL DISTURBANCE OR RE-DISTURBANCE, PERMANENT OR TEMPORARY STABILIZATION MUST BE COMPLETED WITHIN: A.) THREE (3) CALENDAR DAYS AS TO THE SURFACE OF ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES, AND ALL SLOPES STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1); AND B.) SEVEN (7) CALENDAR DAYS AS TO ALL OTHER DISTURBED OR GRADED AREAS ON THE PROJECT SITE NOT UNDER ACTIVE GRADING.

NOTE TO CONTRACTOR:

"EROSION AND SEDIMENT CONTROL SHALL BE STRICTLY ENFORCED."

GENERAL NOTES:

1. CONTRACTOR SHALL PROTECT ALL AREAS ADJACENT TO THE DESIGNATED LIMITS OF DISTURBANCE AND SHALL CONTRACTOR SHALL PROTECT ALL AREAS ADJACENT TO THE DESIGNATED LIMITS OF DISTURBANCE AND SHALL RESTORE ANY AND ALL AREAS DISTURBED DURING CONSTRUCTION TO THEIR ORIGINAL OR BETTER CONDITION. 2. NO DISTURBED AREA SHALL BE LEFT UNSTABILIZED OVERNIGHT UNLESS RUNOFF IS DIRECTED TO AN MDE NO DISTURBED AREA SHALL BE LEFT UNSTABILIZED OVERNIGHT UNLESS RUNOFF IS DIRECTED TO AN MDE APPROVED SEDIMENT CONTROL DEVICE. 3. INFORMATION SHOWN ON THIS DRAWING HAS BEEN PROVIDED AS A GUIDE TO ASSIST THE CONTRACTOR IN INFORMATION SHOWN ON THIS DRAWING HAS BEEN PROVIDED AS A GUIDE TO ASSIST THE CONTRACTOR IN ESTABLISHING THE LOCATIONS OF PROPOSED CONSTRUCTION WITH RESPECT TO EXISTING SITE IMPROVEMENTS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CONSTRUCTION SURVEY LAYOUT REQUIRED AND TO CONFIRM ALL INFORMATION SHOWN HEREON. 4. PHOTOGRAMMETRIC SURVEY PERFORMED BY MERCADO CONSULTANTS, INC. IN MARCH, 2019. BOUNDARY SURVEY PHOTOGRAMMETRIC SURVEY PERFORMED BY MERCADO CONSULTANTS, INC. IN MARCH, 2019. BOUNDARY SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE REPORT. 5. UNDERGROUND UTILITIES ARE SHOWN ON THIS DRAWING FOR THE CONVENIENCE OF THE USER OF THE DRAWING UNDERGROUND UTILITIES ARE SHOWN ON THIS DRAWING FOR THE CONVENIENCE OF THE USER OF THE DRAWING AND THERE IS NO WARRANTY OR GUARANTEE AS TO THE CORRECTNESS OR COMPLETENESS OF THE INFORMATION GIVEN. 6. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF GENERAL SERVICES MANAGER 72 HOURS PRIOR TO COMMENCING ANY WORK. 8. CONTRACTOR SHALL NOT STOCKPILE OUTSIDE LIMIT OF DISTURBANCE. A STOCKPILE AREA HAS BEEN SHOWN. CONTRACTOR SHALL NOT STOCKPILE OUTSIDE LIMIT OF DISTURBANCE. A STOCKPILE AREA HAS BEEN SHOWN. CONTRACTOR SHALL COORDINATE WITH THE DEPARTMENT OF GENERAL SERVICES MANAGER. 9. SEDIMENT CONTROL DETAILS AND NOTES ARE SHOWN ON C-602 THROUGH C-605. SEDIMENT CONTROL DETAILS AND NOTES ARE SHOWN ON C-602 THROUGH C-605. 10. SEE SHEET C-722 FOR SEQUENCE OF CONSTRUCTION. 11. TRENCH WORK SHALL COMPLY WITH THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION EXCAVATION SAFETY TRENCH WORK SHALL COMPLY WITH THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION EXCAVATION SAFETY STANDARDS.

DESIGN CERTIFICATION I hereby certify that this plan has been designed in accordance with the 2011 Maryland Standards and Specifications for Soil Erosion and Sediment Control, the 2000 Maryland Stormwater Design Manual, Volumes I & II including supplements, the Environment Article Sections 4-101 through 116 and Sections 4-201 and 215, and the Code of Maryland Regulations (COMAR) 26.17.01 and COMAR 26.17.02 for erosion and sediment control and stormwater management, respectively. __________ ________________________________ ________________________________ Date Designer's Signature Designer's Signature Md. Registration No.__________ ________________________________ ________________________________ P.E., R.L.S., RLA, or R.A. (circle one) Printed Name Printed Name

INDEX OF SHEETS

SHEET NO.

EROSION & SEDIMENT CONTROL COVER SHEET EROSION & SEDIMENT CONTROL PLAN EROSION & SEDIMENT CONTROL NOTES EROSION & SEDIMENT CONTROL NOTES EROSION & SEDIMENT CONTROL NOTES EROSION & SEDIMENT CONTROL DETAILS

C600 C601 C602 C603 C604 C605

DESCRIPTION

JUDITH A. CARROLL

9/21/2020

1. THE CONTRACTOR SHALL NOTIFY MDE AT (410) 537-3510 SEVEN (7) DAYS THE CONTRACTOR SHALL NOTIFY MDE AT (410) 537-3510 SEVEN (7) DAYS BEFORE COMMENCING ANY LAND DISTURBING ACTIVITY AND, UNLESS WAIVED BY MDE, SHALL BE REQUIRED TO HOLD A PRE-CONSTRUCTION MEETING BETWEEN PROJECT REPRESENTATIVES AND A REPRESENTATIVE OF MDE. THE CONTRACTOR SHALL NOTIFY MDE IN WRITING AND BY TELEPHONE AT THE FOLLOWING POINTS: 1.1. THE REQUIRED PRE-CONSTRUCTION MEETING. THE REQUIRED PRE-CONSTRUCTION MEETING. 1.2. FOLLOWING INSTALLATION OF SEDIMENT CONTROL MEASURES. FOLLOWING INSTALLATION OF SEDIMENT CONTROL MEASURES. 1.3. DURING THE INSTALLATION OF SEDIMENT BASINS (TO BE CONVERTED INTO DURING THE INSTALLATION OF SEDIMENT BASINS (TO BE CONVERTED INTO PERMANENT STORMWATER MANAGEMENT STRUCTURES) AT THE REQUIRED INSPECTION POINTS (SEE INSPECTION CHECKLIST ON PLAN). NOTIFICATION PRIOR TO COMMENCING CONSTRUCTION OF EACH STEP IS MANDATORY. 1.4. PRIOR TO REMOVAL OR MODIFICATION OF ANY SEDIMENT CONTROL PRIOR TO REMOVAL OR MODIFICATION OF ANY SEDIMENT CONTROL STRUCTURE(S). 1.5. PRIOR TO REMOVAL OF ALL SEDIMENT CONTROL DEVICES. PRIOR TO REMOVAL OF ALL SEDIMENT CONTROL DEVICES. 1.6. PRIOR TO FINAL ACCEPTANCE. PRIOR TO FINAL ACCEPTANCE. 2. PROVIDE SURVEY AND LAYOUT OF THE LIMIT OF DISTURBANCE (LOD) AND INITIAL PROVIDE SURVEY AND LAYOUT OF THE LIMIT OF DISTURBANCE (LOD) AND INITIAL EROSION & SEDIMENT CONTROL (ESC) DEVICES. THE LOD MUST BE FIELD MARKED AND THE ORANGE HIGH VIABILITY TREE PROTECTION FENCE SHALL BE INSTALLED PRIOR TO AND INSPECTED AT THE PRE-CONSTRUCTION MEETING. 3. CONDUCT ON-SITE PRE-CONSTRUCTION MEETING WITH ALL PARTIES TO DISCUSS CONDUCT ON-SITE PRE-CONSTRUCTION MEETING WITH ALL PARTIES TO DISCUSS ISSUES INCLUDING, BUT NOT LIMITED TO WAYS AND MEANS AND LIMITS OF RESPONSIBILITIES AND WORK, AND TO INSPECT THE SITE FOR ANY UNFORESEEN CONDITIONS. 4. WITH THE PERMISSION OF THE MDE INSPECTOR, CLEAR AND GRUB FOR WITH THE PERMISSION OF THE MDE INSPECTOR, CLEAR AND GRUB FOR INSTALLATION OF INITIAL/PERIMETER CONTROLS. 5. INSTALL EROSION & SEDIMENT CONTROL DEVICES INCLUDING, BUT NOT LIMITED TO, INSTALL EROSION & SEDIMENT CONTROL DEVICES INCLUDING, BUT NOT LIMITED TO, SILT FENCE (SF), SUPER SILT FENCE (SSF), SILT FENCE ON PAVEMENT (SFOP), AND STABILIZED CONSTRUCTION ENTRANCE (SCE). SET CONTRACTORS STAGING AREA AND STOCKPILE. 6. DEMOLISH EXISTING CONCRETE PAVEMENT, MACADAM PAVEMENT, AND OTHER SITE DEMOLISH EXISTING CONCRETE PAVEMENT, MACADAM PAVEMENT, AND OTHER SITE SURFACE ELEMENTS AS SHOWN ON THE DEMOLITION PLAN. 7. CONCURRENT WITH STEP 6, BEGIN BUILDING CONSTRUCTION. CONCURRENT WITH STEP 6, BEGIN BUILDING CONSTRUCTION. 8. CONCURRENT WITH STEP 6, REMOVE OR ABANDON AND INSTALL UNDERGROUND CONCURRENT WITH STEP 6, REMOVE OR ABANDON AND INSTALL UNDERGROUND UTILITIES. 9.