B.08.02 Attachment E - DCANG F-16 MTC Flight Sim - Corr Final II - Furn Plan & Perf Specs.pdf
PDF 12 MB Posted
- Attached to
- CONSTRUCT F-16 FLIGHT SIMULATOR FACILITY at JOINT BASE ANDREWS, MARYLAND Federal contract opportunity
- Solicitation number
- W912DR22B0004
About this file
This solicitation is for the construction of an F-16 flight simulator facility at Joint Base Andrews in Maryland. The competitive 8(a) invitation for bid requires the construction of a new building to house an F-16 flight simulator, associated equipment, and support spaces. Bids are due by April 5, 2022 and the contract is to be awarded by May 13, 2022. The Department of the Army Corps of Engineers Engineering District Baltimore is the contracting agency overseeing this project on behalf of the DC Air National Guard.
View the file
Other files for this federal contract opportunity
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Corrected Final Submission Furniture Plan & Performance Specifications
NGB Contract: W9133L-16-D-0005 Task Order: W912QG-19-F-0010
DC ANG PN: AJXF 189013
November 8, 2021
F16 Mission Training Facility Furniture, Fixtures, and Equipment Joint Base Andrews, MD
Table of Contents
1. Specification .........................................................................................................................Tab 1
2. Procurement Sheets .............................................................................................................Tab 2
3. Furniture Color Boards ..........................................................................................................Tab 3
4. Furniture Plans......................................................................................................................Tab 4
5. Room Subtotals ....................................................................................................................Tab 5
6. Electrical Plan .......................................................................................................................Tab 6
7. Itemized Cost Estimate .........................................................................................................Tab 7
SECTION 12 59 00
SYSTEMS FURNITURE
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN FOREST FOUNDATION (AFF)
ATFS STANDARDS (2015) American Tree Farm System Standards of Sustainability 2015-2020
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASHRAE 90.1 - SI (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM C1048 (2012; E 2012) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM C423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
ASTM E290 (2014) Bend Testing of Material for Ductility
ASTM E84 (2017) Standard Test Method for Surface Burning Characteristics of Building Materials
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA M7.1 (2011) Standard Test Method for Determining VOC Emissions
ANSI/BIFMA X5.5 (2008) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.6 (2010) American National Standards For Office Furnishings -Panel Systems
CSA GROUP (CSA)
CSA Z809-08 (R2013) Sustainable Forest Management
FOREST STEWARDSHIP COUNCIL (FSC)
FSC STD 01 001 (2000) Principles and Criteria for Forest Stewardship
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
NEMA WD 1 (1999; R 2015) Standard for General Color Requirements for Wiring Devices
NEMA WD 6 (2016) Wiring Devices Dimensions Specifications
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2015; ERTA 2016) Life Safety Code
NFPA 265 (2015) Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;
TIA 17-3) National Electrical Code
PROGRAMME FOR ENDORSEMENT OF FOREST CERTIFICATION (PEFC)
PEFC ST 2002:2013 (2015) PEFC International Standard Chain of Custody of Forest Based Products Requirements
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS)Indoor Advantage
SUSTAINABLE FOREST INITIATIVE (SFI)
SFI 2015-2019 (2015) Standards, Rules for Label Use, Procedures and Guidance
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-568-C.2 (2009; Errata 2010; Add 2 2014; Add 1 2016) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
TIA-569 (2015d) Commercial Building Standard for Telecommunications Pathways and Spaces
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL 1286 (2008; Reprint Feb 2015) Office Furnishings
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
UL 723 (2008; Reprint Aug 2013) Test for Surface Burning Characteristics of Building Materials
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G
SD-03 Product Data
Warranty; G
Workstations
Power and Communications
Communications
SD-04 Samples
Workstations; G
Samples
SD-06 Test Reports
Selected Components; G
Panel Acoustics; G
Fire Safety; G
Electrical System; G
SD-07 Certificates
Workstations
Certified Sustainably Harvested Wood
Indoor Air Quality
SD-08 Manufacturer's Instructions
SD-10 Operation and Maintenance Data
Assembly Manuals; G
Maintenance Manuals; G
Cleaning; G
Electrical System; G Installation; G
1.3 CERTIFICATIONS
1.3.1 Certified Sustainably Harvested Wood
Provide wood certified as sustainably harvested by FSC STD 01 001, ATFS STANDARDS, CSA Z809-08, SFI 2015-2019, or other third party program certified by PEFC ST 2002:2013. Provide a letter of Certification of Sustainably Harvested Wood signed by the wood supplier. Identify certifying organization and their third party program name and indicate compliance with chain-of-custody program requirements. Submit sustainable wood certification data; identify each certified product on a line item basis. Submit copies of invoices bearing certification numbers.
1.3.2 Indoor Air Quality Certifications
1.3.2.1 Office Furniture Systems and Seating
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold, ANSI/BIFMA M7.1 Certification or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body.
1.4 QUALITY ASSURANCE
1.4.1 General Safety
Provide workstation products free of rough or sharp edges. Provide desk-based workstation components with an option for a positive, integral locking device that secures components to the base units.
1.4.2 Fire Safety
Components must meet requirements for flame spread and smoke development as specified by NFPA 101 except as follows. Conduct testing in accordance with either ASTM E84 or UL 723 on the entire assembled panel of the worst case (most combustible) combination of fabric and interior construction.
In addition, fabric must meet the requirements of NFPA 265. Do not exceed 25 for Class A for panel flame spread and 450 for Class A, B and C panel smoke development.
1.4.3 Electrical System
Task lights are required to be UL listed and installation of task lighting must meet the requirements of NFPA 70. The electrical system must meet the requirements of UL 1286. Submit three sets of electrical system manuals describing the functions, configuration, and maintenance of the electrical system (power , communications ). This material may be included in the Assembly or Maintenance manuals at the Contractor's option.
1.4.4 Detail Drawings
Submit detail drawings showing communications, electronic data processing (EDP) and local area network (LAN); locations may be provided as a separate submittal from remaining workstation drawings. Provide drawing requirements, which are the furniture manufacturer's responsibility, as a single submittal. Provide electronic drawings to the user for future re-configuration in the software package requested by the user. Include in the electronic drawings all modifications made during installation. As a minimum, submit the following:
a. Overall reference drawings: Drawings showing workstation locations and overall plan view within each floor in a scale of 1/8 inch = 1 foot.
Layouts must reflect field verified conditions and clearly illustrate the overall space planning concept and intent.
b. Installation drawings: Drawings showing workstations, panels, components, and plan view within each floor. Identify workstations by workstation type; submit drawings showing the proposed workstation installation at a scale of 1/4 inch = 1 foot, unless otherwise specified. Installation drawings must reflect field verified conditions.
c. Workstation elevations: Dimensioned workstation elevations showing each type of workstation with panel frame configurations and all components identified with manufacturer's catalog numbers. Draw elevations at 1/2 inch = 1 foot scale.
d. Panel drawings: Panel drawings showing locations and critical dimensions from finished face of walls, columns, panels, including clearances and aisle widths. Key assemblies to a legend which includes width, height, configuration and composition of frame covers finishes and fabrics (if different selections exist within a project), power or nonpower, connectors and wall mount hardware. Coordinate panel placement with location of electrical, voice/date LAN, NIPERNet, mechanical and fire protection fixtures. Drawings must reflect field verified conditions.
e. Electrical drawings: Drawings showing power provisions including type and location of feeder components (service entry poles, base or ceiling feeds), activated power receptacles and other electrical components.
Wiring configuration (circuiting, switching, internal and external connections) identified and a legend provided as applicable. Identify which receptacles in typical furniture configurations will be connected to controlled building power circuits as applicable to meet ASHRAE 90.1 - IP requirements. Coordinate with electrical drawings.
f. Wire management capacity drawings.
g. Communication drawings showing telephone provisions: Drawings indicating the type and location of feeder components and communications jacks with wiring configuration identified where applicable.
h. Communication drawings showing electronic data processing provisions:
Drawings indicating the type and location of feeder components, communications jacks, or accessories with wiring configuration identified where applicable.
i. Communication drawings showing local area network provisions: Drawings indicating the type and location of feeder components and data jacks with extra ports for future expansion with wiring configuration identified where applicable.
j. Communications drawings indicating the TIA-568-C.2 pin/pair assignment that will be used for communications outlet as coordinated with the COR.
k. Reflected ceiling plan for projects specified with power poles.
l. Drawings indicating cabling is protected at all transition points, and that metallic separation is provided between telecommunication and power wiring in the utility columns and systems furniture track in accordance with TIA-569 and NFPA 70.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver components to the jobsite in the manufacturer's original packaging with the brand, item identification, and project reference clearly marked.
Remove furniture from packaging and store in an unoccupied, dry location that is ventilated. Storage shall be free from dirt and dust, water, and other contaminants, and in a manner that permits easy access for inspection and handling.
1.6 WARRANTY
Warrant the systems furniture for a minimum period of 12 years with the following exceptions: fabrics and other covering materials, and paper handling products for 3 years, LED drivers/power supplies for 5 years, and electromagnetic ballasts for 3 years. Warranties must be signed by the authorized representative of the manufacturer. Present warranties, accompanied by document authenticating the signer as an authorized representative of the guarantor, to the Contracting Officer upon the completion of the project. Guarantee that the workstation products and installation are free from any defects in material and workmanship from the date of delivery. Submit two copies of the warranty.
PART 2 PRODUCTS
2.1 MATERIALS
Provide System Furniture Components with a minimum of 55 percent recycled content. Provide data identifying percentage of recycled content for system furniture components.
Provide certification of indoor air quality for Office Furniture Systems and Seating.
2.2 PRODUCT SUSTAINABILITY CRITERIA
For products in this section, where applicable and to extent allowed by performance criteria, provide the following:
2.2.1 Reduced Volatile Organic Compounds (VOC) (Low-Emitting Materials)
Provide furniture in compliance with the minimum emissions requirements as specified in <SRF>01 33 29</SRF> SUSTAINABILITY REPORTING, Table 3-1
VOLATILE ORGANIC COMPOUNDS (VOC) (LOW-EMITTING MATERIALS) REQUIREMENTS.
2.2.2 Recycled Content
Provide furniture in compliance with minimum recycled content requirements listed below.
Furniture structure (steel): provide a minimum of 16% postconsumer content and 25-30% total recovered materials content.
Furniture structure (aluminum): provide a minimum of 75% total recovered materials content.
Cellulose Loose-Fill and Spray-On (Postconsumer Paper): provide a minimum of 75% postconsumer content.
Particleboard/Fiberboard component (Wood or wood composite): provide postconsumer content greater than 0% and a minimum of 80% total recovered materials content.
Particleboard/Fiberboard component (Agricultural fiber): provide 100% total recovered materials content.
Fabric (PET): provide 100% postconsumer content.
Plastic furniture component (HDPE): provide a minimum of 70-75% postconsumer content and 95% total recovered materials content.
2.1.4 Bio-Based Content
Where applicable and to extent allowed by performance criteria, provide furniture with bio-based content.
2.3 SYSTEM DESCRIPTION
2.3.1 Workstations
This specification establishes the minimum requirements for the acquisition and installation of a complete and usable system of workstations composed of panels, freestanding work surfaces or base units, supporting components, electrical hardware, communications, special electrical features, and accessories. Provide workstation requirements and configurations in accordance with the furniture layout and typical workstation types shown in drawings and specified herein. Provide components and hardware from a single manufacturer that are standard products as shown in the most recent published price lists or amendments. Proposed product must be part of the manufacturer's current line with no intent to discontinue within two years. Submit complete listing of part/model numbers for all components to be provided, including names and codes of components referenced on updated drawings. Provide electrical components from a single manufacturer to the extent practicable (different types of components may be of different manufacturers, but all units of a given component must be from a single source). Conformance with NFPA 70, UL 1286, NFPA 101, and 36 CFR 1191 is required. Coordinate the work of this section with that to be performed under other sections. This specification may include items which are not manufactured by the furniture manufacturer; provide any such items under this section. Submit two complete sets of certificates attesting that the proposed workstation meets specified requirements. Date the certificate after the award of the contract, include the name of the project, and list specific requirements being certified.
2.3.2 Samples
Submit samples as required to obtain final approval. The Government reserves the right to reject any finish samples that do not satisfy the technical or color requirements. Work can not proceed without sample approval in writing from the Contracting Officer. Submit four sets of the finish samples listed below:
a. Panel, tackboard and overhead door fabric. Minimum 6 by 6 inches with label designating the manufacturer, pattern, color, fiber content, fabric width, fabric weight, fire rating, and use (panel and/or tackboard).
b. Workstation component finishes. Minimum 2-1/2 by 3 inches with label designating the manufacturer, material composition, thickness, color, and finish.
c. Personal Task lights (Not overhead task lights).
d. Panel glazing. Glazing samples with label designating the material and safety ratings.
2.3.3 Alternate Design
Manufacturers who are unable to provide workstations that conform exactly to the furniture layouts and typical workstation types shown in the contract drawings, may submit alternate designs for consideration by the
Contracting Officer. Alternate designs must meet or exceed the following criteria. Alternate designs that are submitted but do not meet these criteria will be rejected. In the alternate design provide workstations and components of the same basic size and configuration shown, with only the sizes of the individual components within the workstation changed to meet the standard product of the manufacturer or site conditions.
2.3.3.1 Component Requirements
Provide the types of components or elements as shown on the drawings and as specified in PART 2 PRODUCTS of this specification. Do not reduce the storage capacity, number of workstations accommodated, width of aisles, or workstation configuration.
2.3.3.2 Wiring Configuration
Alternate configurations shall support the circuiting and connection capabilities identified under the provisions pertaining to power distribution of paragraph POWER AND COMMUNICATIONS. Generally any alternate will be acceptable which involves only a variation in size or quantity that exceeds the specified configuration.
2.3.4 Performance Requirements
Panels, frames and frame covers, connection system, work surfaces, pedestals, shelf units, overhead door cabinets, lateral files, locks, accessories, and miscellaneous hardware must meet testing as specified.
ISO 9001 certified manufacturers may perform in-house testing.
Manufacturers not ISO 9001 qualified will be required to produce testing by an independent testing laboratory. Component specific requirements are listed in appropriate paragraphs.
2.3.4.1 Selected Components
Workstation conformance to ANSI/BIFMA X5.5 and ANSI/BIFMA X5.6 is required with the following exceptions: Panels, or panel supported components conformance to ANSI/BIFMA X5.6 is required. Representative items will be selected for testing based on worst case situations (i.e., the deepest and widest work surface or shelf). Perform the keyboard drawer or shelf test applying a 50 lb load to the center of the keyboard shelf for a period of 5 minutes. Any loosening of attachments or damage to the operation of the drawer or shelf will be cause for rejection.
2.3.4.2 Panel Acoustics
Provide acoustical panels with a minimum noise reduction coefficient (NRC) of 0.65 when tested in accordance with ASTM C423 and a minimum sound transfer coefficient (STC) of 14 when tested in accordance with ASTM E290.
Conduct the test on the entire assembled panel, full face area (the complete core, adhesive, decorative fabric, frame and joining components).
2.3.5 Pattern and Color
Provide pattern and color of finishes and fabrics for panel systems, components, and trim as shown in Basis of Design document for furniture and furniture systems..
2.4 SYSTEMS FURNITURE
2.4.1 Panel System Components
Supply aaccessories and appurtenances for a completely finished panel assembly with the system. Provide a system capable of structurally supporting cantilevered work surfaces, shelves, files, overhead cabinets, and other components in the configurations shown on the drawings plus more than one fully loaded component per panel per side. Provide panels that are tackableorcapable of accommodating fabric covered tackboards, . Segments will be field removable from both sides of the panel. Provide a spine wall system where electrical and data management will be easily accessible by removable wall covers that can be removed while workstation components are still attached. Cables must be laid in the system, not threaded through the frame. Provide a panel system that is available in a variety of nominal widths and heights as designated on the drawings. Measure heights from the finished floor to the top of the panel. Supply powered and nonpowered panels that are compatible in height. Coordinate panel heights with the HVAC and electrical designs. Minimum panel thickness is 3 inches thick. Submit three sets of Assembly Manuals describing assembly and reconfiguration procedures.
2.4.2 Panel Finishes
Provide panels in the following options: open frame, tackable fabric, marker surface, paint, . Frame covers may have different options on either side of the frame. Exposed panel trim to have a factory baked enamel or epoxy powder finish. Filler trim will either match the panel trim or be fabric covered to match the panel fabric. Provide each fabric-faced panel with a seamless width of fabric stretched over the entire face of the panel. The fabric color throughout the installation must be consistent.
Curved panels may use adhesives on curved sections. Attach the fabric securely and continuously along the entire perimeter of the panel and allow for easy removal and replacement in the field (with the exception of curved panels).2.4.3 Raceways
Provide raceways and covers as an integral part of the panel whether powered or nonpowered. Magnet held base covers will not be accepted.
2.4.4 Leveling Glides
Provide precise alignment of adjacent panels and include leveling glides to compensate for uneven floors. Provide quantity and location of leveling glides as recommended by the manufacturer. A minimum 3/4 inch adjustment range is required.
2.4.5 Connection System
Provide connectors which accommodate a variety of configurations as indicated on the drawings to include: a straight line connection of 2 panels (180 degrees), corner connection of 2 panels (90 degrees), T connection of 3 panels (90 degrees), cross connection of 4 panels (all 90 degrees),. Provide tight connections with continuous visual and acoustical seals. Plastic, painted metal, fabric or wood finish connections are required to match system. Provide connector system that allows removal of a single panel within a typical workstation configuration, without requiring disassembly of the workstation or removal of adjacent panels.
Provide for connection of similar or dissimilar heights to include trim pieces to finish the exposed edge. Right angle (90 degree) connections between panels must not interfere with the capability to hang work surfaces and other components on any adjacent panel. Provide, as required, the continuation of electrical and communications wiring within workstations and from workstation to workstation. Filler posts must be level with the top rail.
2.4.6 Wall Mounted Panels
Use wall-mount components when it is necessary to attach panels or vertical panel-frame assemblies to the building walls. Provide structural support for wall panels as required. Panels and other systems furniture components are not be wall mounted unless they are included in the original design.
2.5 DESK-BASED SYSTEM
Supply accessories and appurtenances for a completely finished desk-based assembly within the system. Provide a desk-based system that is free-standing, independent of panel system support and capable of structurally supporting work surfaces, shelves, and other components in the configurations shown on the drawings. Provide a variety of nominal widths and depths as indicated on drawings.
2.6 WORK SURFACES
2.6.1 Construction
Construct work surfaces to prevent warpage. Fully support work surfaces from the panels or support jointly by the panels and supplemental legs, pedestals, or furniture end panels. Use supplemental end supports only under work surfaces when the work station configuration does not permit full support by the panels. Use metal support brackets to support work surfaces from the panels, provide metal-to-metal fitting to the vertical uprights of the panels, vertically adjustable, to lock the work surfaces in place without panel modifications. Abutting work surfaces must line up closely and be at equal heights when used in side-by-side configurations in order to provide a continuous and level work surface. Provide pre-drilled holes to accommodate storage components, pedestals and additional supports in work surfaces, or drill holes at the job site to accommodate these items. Provide work surfaces in sizes and configurations shown on the drawings. Provide work surfaces in nominal depths of 24 inches, plus or minus 2 inches, nominal lengths from 24 to 72 inches, and a nominal thickness from 1 to 1-3/4 inches. Provide corner, peninsula, and counter/transaction work surfaces as shown on the drawings and include hardware necessary to provide firm and rigid support.
2.6.2 Finishes
Provide work surfaces with a finished top surface of high pressure plastic laminate, and a smoothly finished underside. The work surface must not be damaged by ordinary household solvents, acids, alcohols, or salt solutions. Provide metal support brackets that match the color and finish of trim. Provide laminate edges
2.7 PEDESTALS
Provide drawer configurations and pedestal height as shown on the drawings. Provide the deepest possible pedestal for each work surface size specified. Free standing mobile pedestals to include an attached upholstered seat cushion, casters. Mobile pedestals must be load bearing and equipped with counterbalance as standard. Provide appropriate height of mobile pedestal so it can be stored under a standard height worksurface.
2.7.1 Construction
Provide pedestals and drawers of steel construction with the exception of drawer fronts. Securely attach drawer faces to the drawer front.
2.7.2 Finishes
Provide a factory baked enamel finish or powder coated for steel surfaces.
Provide plastic laminate drawer fronts.
2.7.3 Drawer Requirements
Pedestals must be field interchangeable from left to right, and right to left, and must retain the pedestal locking system capability. Design pedestals to protect wires from being damaged by drawer operation. Provide pedestals that are free standing ormobile. Drawers must stay securely closed when in the closed position and provide each drawer with a safety catch to prevent accidental removal when fully open. File drawers to be provided with full extension ball bearing drawer slides or rack and pinion suspension. File drawers to be provided with hanging folder frames or rails and capable of hanging side-to-side or front-to-back. Provide dividers with vertical files.
Provide box drawers with pencil trays. Provide center pencil drawer and mount under the work surface.
2.8 STORAGE
Provide storage units in the sizes and configurations shown on the drawings. Provide task lights under overhead cabinets. Depth to accommodate a standard three ring binder
2.8.1 Shelf Unit Construction
Provide metal construction shelf pan with formed edges. Provide shelf supporting end panels of metal, high density particle board, molded phenolic resin, or molded melamine. Provide relocatable shelf dividers with shelf units.
2.8.2 Overhead Cabinet Construction
Provide metal construction overhead cabinets. Provide doors with a suspension system. Provide overhead cabinet door that retracts into the cabinet.
2.8.3 Lateral File, Vertical File Construction
Provide units and file fronts, top and end panels of steel construction.
File drawers to be provided with full extension ball bearing drawer slides or rack and pinion suspension. File drawers to be provided with hanging folder frames or rails and capable of hanging side-to-side or front-to-back. Provide dividers with vertical files.
2.8.4 Personal Storage Tower Construction
Provide personal storage tower and components of steel construction.
Height of the unit to be the same height as the surrounding panels. The personal storage tower will include one full height wardrobe unit with coat rod, two file drawers, bookcase with two adjustable shelves, and hinged lockable doors.
2.8.5 Finish
Provide a factory baked enamel or epoxy powder coat finish for shelves, dividers and top dust cover. Provide either a factory baked enamel, epoxy powder coat or laminate finish for shelf supporting end panels. Shelf bottom is required to match end panel color. Provide metal doors with an exterior finish of factory baked enamel and an interior finish of factory baked enamel or epoxy powder coat. Provide a factory baked enamel finish or epoxy powder coat on metal drawers.
2.9 ACCESSORIES
2.9.1 Coat Hook
Provide one mounted coat hook per workstation.
2.9.2 Keyboard Tray
Provide work surfaces that are capable of accepting an articulating keyboard in locations as shown on the drawings. The keyboard tray must be capable of fully recessing under the work surface and extending to give the user full access to the keyboard. Provide height adjustability, 180-degree swing side travel rotation and negative tilting capability. Include a wrist support and a mouse pad at the same level as the keyboard tray to accommodate either right or left-handed users.
2.9.3 Tackboards
Fabric must be factory installed. Location and size as shown on the drawings.
2.9.4 Erasable Marker Boards
Provide marker boards with a white writing surface that can be easily written on and erased and unaffected by common marker board cleaning/conditioning agents. Include a storage tray and minimum two markers with the markerboard. Size and location as shown on the drawings.
2.9.5 Paper Management Unit
Provide paper management units as indicated on the drawings . Construct these units of coated steel or injection molded plastic to accommodate either legal or letter size lengths.
2.9.6 Wall Mounted Components
Provide wall tracks when components are shown attached directly to wall surfaces. Provide tracks of heavy duty extruded metal with finish and color matching the the panel trim. Provide vertically aligned tracks slotted on 1 inch centers in heights required that match slot spacing for components.
2.9.7 CPU Holder
Provide a mounting to support the computer hard drive. Desk top and floor locations are not acceptable.
2.9.8 Signage
Provide panel mounted signage composed, at a minimum, of aluminum frame, back panel, clear plastic cover, and hanging device. Provide signage approximately 3 by 8 inches and capable of receiving a replaceable standard white paper insert. Match base standardtext type. Provide software for creating text in PC computers for owner production of replacement paper inserts after project completion.
2.9.9 Slat Tile
Provide slat tile with channels to accommodate attachments such as monitor arm, task light and organizer accessories. Provide maximum slat tile height of 12 inches and a length as shown on the drawings. Slat tile must be integral to the panel and not attached to the surface of the panel.
2.10 MISCELLANEOUS HARDWARE
Provide brackets, supports, hangers, clips, panel supported legs, connectors, adjustable feet, cover plates, stabilizers, and other miscellaneous hardware that contribute to a complete and operable furniture system.
2.11 LOCKS AND KEYING
Provide overhead cabinets, vertical files, personal storage towers, pedestals and lateral files with keyed locks, unless otherwise noted.
Provide field changeable lock cylinders with a minimum of 100 different key options. Key each workstation individually, and key locks alike within a workstation. Provide lockable drawers within a pedestal either by a central lock that controls all pedestals under one work surface or an individual keyed lock in each pedestal. Key alike central file and storage units which are grouped together but are not a part of a workstation unless otherwise specified. Provide two keys for each lock or two keys per workstation when keyed alike, and provide three master keys per area as indicated. Number keys and lock cylinders for ease of replacement. Clearly label locks with a key number, except for those manufacturers who have removable format locks.
2.12 POWER AND COMMUNICATIONS
Provide both powered and nonpowered panels with base raceways capable of distributing power circuits, communication cables . Provide nonpowered bases that are capable of easy field conversion to powered base without requiring the panel to be dismantled or removed from the workstation.
Provide panels able to support lay-in cabling and having a large capacity for power and data. Provide ample space for storing excess wires and fiber optic cables in the interior of the spine wall frame. Provide easy access to power and data systems in the spine wall without having to move return panels or components. Provide the ability for the spine wall system to supply power to a wall-attached panel system and/or an adjacent desk system. A termination center or utility closet may be utilized in the wall or at the end of a panel run. Provide copper cable assemblies, wiring harnesses or electrified bus for the system and meet the requirements of UL 1286 and NFPA 70, Article 605. Provide conductors with 20 amp 90 degree C, #12 AWG wires (unless indicated otherwise) or the equivalent in the bus configuration. A single circuit must not serve more than four (4) cubicles or workstations under any circumstances. The label or listing of Underwriter's Laboratories, Inc. will be accepted as evidence that the material or equipment conforms to the applicable standards of that agency.
In lieu of this label or listing, submit a statement from a nationally recognized, adequately equipped testing agency indicating that the items have been tested in accordance with required procedures of UL and that the materials and equipment comply with contract requirements. Electrical work not addressed in this section must conform to the requirements of Section
26 20 00.23 INTERIOR DISTRIBUTION SYSTEM.
2.12.1 Panel Raceways
Provide panels that have hinged or removable covers that permit easy access to the raceway when required but are securely mounted and cannot be accidentally dislodged under normal conditions. Place raceways in locations such as the base, beltline, and below and above the beltline.
The raceway must not extend past either panel face by more than 1/2 inch.
Provide metal or plastic covers which attach securely to the raceway as required and match the finish and color of the panel trim. Provide a minimum of 2 knockouts (doors) per side for power receptacles and communications jacks as indicated in raceways on panel frames. Provide other raceways that are flush with panel face.
2.12.2 Power Distribution
Provide power distribution as indicated on the drawings. Provide an internal power and communications raceway and the capability of disconnecting and connecting external circuits to the electrified raceway in the panel. Capacity for at least twelve 4-pair category 6 cables is required for the communications receiving raceway. Power and communications wiring may share a common wireway if a metal divider is included to ensure electrical isolation. Provide doors or access openings for entry of communications cable. Provide the electrified power raceway for the 10-wire8-wire6-wire or 5-wire configuration indicated.
2.12.2.1 Receptacles
Provide power receptacles in the powered panels. Place devices at the locations indicated on the plans connected to the designated circuits.
Electrical power receptacles and communications jacks should have the ability to be hung at multiple vertical increments throughout the frame via power harnesses. Unless otherwise indicated, receptacles must be 20 amp (NEMA 5-20R) commercial grade conforming to NEMA WD 1 and NEMA WD 6.
Provide 10 percent spare devices of each type shown on these plans if receptacles are not interchangeable or will not permit field adjustment of phase and circuit selection. All receptacles are required to be of the duplex configuration; unless otherwise indicated, special use receptacles are required to be of the simplex configuration with the blade/pin arrangement identified on the plans. Coordinate the color of receptacle bodies with the color of the panel trim. Isolated ground receptacles must be orange or be of a different color than other receptacles. Furniture receptacles whose building power supply circuit is controlled by an energy management system, timer, or some other automatic means or are provided with local automatic control, will be identified using the standard symbol shown in NFPA 70 Figure 406.3(E); each outlet on a multi-outlet receptacle shall be identified individually. Provide field applied identification that is permanent; stick-on or non-setting adhesives are not acceptable.
Provide 5 percent spare devices for each configuration and type of receptacle. Provide a minimum of 5 receptacle removal tools for systems that require special tools for proper receptacle removal.
2.12.2.2 Power Cabling Variations
The paragraph Power Distribution has identified specific cabling configurations. Since universal conventions have not been established, variant configurations available from various manufacturers will be considered. Alternates shall allow the same circuiting, device connections, neutral and ground separation, and upstream feeder connections as shown on the plans. See paragraph ALTERNATE DESIGN. An example of an acceptable variation includes the use of a manufacturer's configuration which allocates individual conductors differently, but which has the same quantity of conductors and allows devices to be physically connected in the field as shown on the plans. It is not necessary that the manufacturer's labeling codes or terminology match the designations used on project plans or in the specifications; however, neutrals and grounds shall have insulation color coded per standard practice or be provided with tags, colored tape, colored ribbons or similar identification. (The reference to "dedicated" conductors in this specification pertains to circuit connections upstream and load connections downstream of panels; it is not necessary that manufacturer's designations correspond.)
2.12.3 Electrical Connections
2.12.3.1 Internal Connections
Utilize straight or flexible plug/receptacle connector assemblies for internal panel-to-panel power connections and provide the powered configurations shown on the drawings.
2.12.3.2 Connections to Building Services
Supply external power and communications services to the panels via direct-wired top entry modules. Do not use cord and plug assemblies for any portion of external links. Top entry junction box assemblies are required to extend the power and communications wiring into service entry poles attached to the electrified panels. External wiring must conform to Section 26 20 00.23 INTERIOR DISTRIBUTION SYSTEM.
2.12.4 Wire Management
Provide wire management capability at all workstations and accommodate all cable types specified, including the applicable manufacturer required bending radius at corners. Design raceways and interfaces to the raceways to accommodate the bend radius as shown in TIA-569 for Category 6 communication wiring . Copper and fiber cabling shall meet the requirements of Section 27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM. The capability may be accomplished by cable access cutouts (1 minimum per work surface), covered wire management troughs in vertical end panels, horizontal wiring troughs, internal midpanel (beltline) raceways, or rear gaps (between the back edge of the work surface and the facing support panel). Provide grommet kits or another suitable finish arrangement for all cable cutouts. Provide accessories for an externally mounted vertical and horizontal wire management and concealment system as recommended by the manufacturer. Supply horizontal wire managers for mounting under all work surfaces. Attach the wire managers either to the underside of the work surface or to the vertical panel without damaging the face. Exposed or loose wiring will not be acceptable. Wire managers must be prefinished and secure, conceal, and accommodate outlet cords as well as electrical and communications wiring. Wire channels are required to match color of panel trim, attach by means of clip-on attachment, and conceal wires routed vertically. Separate power wiring from communication wiring by use of separate raceways or by placement of channels in joint use troughs or wireways.
2.12.5 Circuit Layout
Provide the circuit layout for workstations on the drawings. Connect devices to the designated circuits in the neutral, ground, and automatic control configurations indicated. Connections must be made to the building electrical distribution system as shown on the contract drawings and in accordance with Section 26 20 00.23 INTERIOR DISTRIBUTION SYSTEM.
2.12.6 Service Entry Poles
Provide service poles, as indicated on the contract drawings, and capable of minimally accommodating the 8-wire power configuration and the equivalent of six 4-pair category 6 cables. Poles musthave metal barriers or channels to separate power and communications wiring. Pole dimensions can be equal to maximum panel thickness. Designated poles are required to have the capability of being opened along the vertical access to permit the lay-in of wiring. Provide each pole with a wiring interface, an end cap and a ceiling trim plate which extends a minimum of 1-1/2 inches from all sides of the pole.
Include a junction box either as part of the pole assembly or in a field installed configuration with poles for power service. Service poles must be securely attached to the panels and installed plumb. Provide wiring and interface components as required to connect the building power supply to power poles.
2.12.7 Task Lighting
Provide task lights with light emitting diode (LED) technology to include a built-in reflector and shielding device that prevents direct glare into an occupant's eyes when they are in a typical working position. Provide task light size and placement on the contract drawings. It is required that lights be a standard component of the manufacturer's workstation products, and the ends of the task light length can not extend beyond the edges of the overhead cabinet. Enclose task light power cords within vertical wire cover or clips. Luminaires shall be UL approved for use in the configurations indicated on the drawings.
2.12.7.1 Luminaire Configuration
Provide luminaires and lamps as specified in Section 26 51 00 INTERIOR LIGHTING and modified herein. For undershelf or undercabinet lighting, provide luminaires that are type and have prismatic lenses, baffles, or other shielding device configured to minimize glare by shielding the lamp from view of the seated user. For fluorescent-type luminaires, provide built-in reflectors. Provide task lights for each workstation with a minimum of 60 footcandles of light (horizontally measured) without veiling reflections, on the work surface directly below and a maximum of 20 inches from the luminaire. Easily removable diffusers, grilles, or other coverings are required to allow for cleaning and relamping. For LED-type task lighting, power consumption shall not exceed 8 watts per foot.
Correlated Color Temperature (CCT) of task lighting shall match the CCT of the ambient room lighting. Provide an easily accessible on-off switch and one ballast or driver per luminaire. A variable intensity control is acceptable if the low setting is equivalent to "off" with zero energy consumption. Multiple level switching is also acceptable. For LED type technology, ganged luminaires or shared drivers are permitted for up to 4 continuous feet in length. A single driver designed for use with an individual LED housing of greater than 4 feet in length is allowed.
2.12.7.2 Wiring
Provide each luminaire with a 6 foot minimum, factory installed, heavy duty electrical cordset with a grounded plug for luminaries that are mounted on the same wall as the receptacle. Provide luminaires mounted on non-powered wall with a 9 foot minimum, factory installed heavy duty electrical cordset with a grounded plug. Direct or hard wire connections are not acceptable.
Unless otherwise indicated, conceal cord. Built-in cord concealment is required within panels or utilize field installed, manufacturer approved accessories. Cords may be extended through dedicated channels located at any point within panels or may be placed in vertical slots or in the space between panels if held in place by retainers and concealed by a cover plate. Vertical wire managers are required to be prefinished and cut to size and shall extend from the task light level down to the top of the work surface below the task light. Attach each manager to a panel vertical edge or connector strip without damage to the surfaces.
2.12.7.3 Control Device
Provide task lighting with a manual ON/OFF switch.
2.12.8 Communications
Communications wiring will be extended to, and installed in, the electrified panels as shown on the plans. Install communications jacks at designated locations. Communications work may be performed in conjunction with the installation of workstations or may be separately executed at the Contractor's option; however, equipment, materials, and installation must conform to the requirements of Section 26 20 00.23 INTERIOR DISTRIBUTION SYSTEM , and properly coordinate all interfaces.
2.12.9 Special Systems
Provide management for secure and nonsecure power, computer and telecommunications cabling through designated raceway systems. Separate secure distribution from nonsecure distribution by running secure lines along top located raceway and nonsecure along the bottom of the workstation panel.
PART 3 EXECUTION
3.1 INSTALLATION
Install the workstations using certified installers in accordance with manufacturer's recommended installation instructions. A licensed electrician is required to hardwire the workstations. Install workstation components level, plumb, square, and with proper alignment with adjoining furniture. Securely interconnect and attach components to the building where required. Provide three sets of special tools and equipment necessary for the relocation of panels and other components. Verify that equipment is properly installed, connected, and adjusted.
3.2 CLEANING
Provide cleanup as specified in Section 01 78 00 CLOSEOUT SUBMITTALS. Upon completion of installation, clean and polish all products and leave the area in a clean and neat condition. Any defects in material and installation are required to be repaired, and damaged products that cannot be satisfactorily repaired are required to be replaced. Submit three sets of Maintenance Manuals describing proper cleaning and minor repair procedures.
-- End of Section --
BASE: F-16 Mission Training Center (MTC) PROJECT: NGBJV/DC - Flight Simulator
DATE: 11/8/2021
SHEET: 001
103 (1), 104 (7), 111 (2), 127 (3)
ITEM: TASK CHAIR ITEM CODE: CH1
EXP Date: GSA #:
BPA #:
MANUFACTURER:
Steelcase 901 44th Street Grand Rapids MI 49501
ORDERING ADDRESS
DESCRIPTION: QTY: UNIT COST: TOTAL COST:
ITEM: Think Task Chair $693.51
MODEL: 465A000
SIZE: 28.5"W x 24.25"D x 21.5"H
Upholstered seat and back task chair, adjustable arms, adaptive bolstering allows seat to form to your shape, height adjustable, flexible seat edge, casters, back flexors track the natural shape of your spine, dual energy lumbar, Cradle to Cradle certified, UPHOLSTERY: Brisa, BR01 Black Onyx
FINISH: Frame: Platinum Metallic 4799
13 $9,015.63
ITEM PHOTO/FINISH SAMPLES:
TOTAL: $9,015.63
DEALER PHONE NUMBER:LOCAL REP:
GOVERNMENT ID CONTACT:
PROJECT ID CONTACT: Sarah Green, Frankfurt Short Bruza Associates, PC, (405) 840-2931
ANY VARIANCE OR MODIFICATION OF THIS SPECIFICATION WILL BE COORDINATED THROUGH
INSTALLATION NO.:
ROOM LOCATION / FOB / REMARKS:
FREIGHT/SHIPPING (FOB ORIGIN):
SNG
Text Box Image is for representation of furniture only and does not reflect specified finishes. Refer to finish samples for specified finishes.
SNG
Text Box Seat & Back Upholstery
SNG
Text Box Frame & Base Finish
DATE: 11/8/2021
SHEET: 002
114 (5), 118 (5), 120 (5), 122 (1), 124 (5), 128 (5)
ITEM: MULTI-USE CHAIR ITEM CODE: CH2
EXP Date: GSA #:
BPA #:
MANUFACTURER:
KI
1330 Bellevue Street Green Bay WI 54302
ORDERING ADDRESS
DESCRIPTION: QTY: UNIT COST: TOTAL COST:
ITEM: Torsion On the Go! Nesting Chair $383.00
MODEL: TGNAUB
SIZE: 23.5"W x 24.25"D x 32.25"H
Upholstered multi-use nesting chair, armless, with hard floor casters.
UPHOLSTERY: KI - Umbel, Black VUBC
FINISH: Frame: KI - Starlight Silver Metallic SX
26 $9,958.00
ITEM PHOTO/FINISH SAMPLES:
TOTAL: $9,958.00
DEALER PHONE NUMBER:LOCAL REP:
GOVERNMENT ID CONTACT:
PROJECT ID CONTACT: Sarah Green, Frankfurt Short Bruza Associates, PC, (405) 840-2931
ANY VARIANCE OR MODIFICATION OF THIS SPECIFICATION WILL BE COORDINATED THROUGH
INSTALLATION NO.:
ROOM LOCATION / FOB / REMARKS:
FREIGHT/SHIPPING (FOB ORIGIN):
SNG
Stamp
SNG
Text Box Image is for representation of furniture only and does not reflect specified finishes. Refer to finish samples for specified finishes.
SNG
Stamp
SNG
Text Box Seat and Back Upholstery
SNG
Stamp
SNG
Frame Finish
DATE: 11/8/2021
SHEET: 003
114 (36)
ITEM: FIXED SEAT W/ TABLET ITEM CODE: CH3
EXP Date: GSA #:
BPA #:
MANUFACTURER:
KI
1330 Bellevue Street
Green Bay WI 54302
ORDERING ADDRESS
DESCRIPTION: QTY: UNIT COST: TOTAL COST:
ITEM: Single Pedestal Fixed Seating $283.50
MODEL: TGNAUB
SIZE: 23.5"W x 24.25"D x 32.25"H
Single Pedestal Fixed Seating with Torsion Air style seat, G2 tablet arm (35 right-handed, 3 left-handed), and Basic Base.
UPHOLSTERY: KI - Umbel, Black VUBC
FINISH: Frame: KI - Starlight Silver Metallic SX; Tablet: KI - Grey Lam
1500-60 LGE
36 $10,206.00
ITEM PHOTO/FINISH SAMPLES:
TOTAL: $10,206.00
DEALER PHONE NUMBER:LOCAL REP:
GOVERNMENT ID CONTACT:
PROJECT ID CONTACT: Sarah Green, Frankfurt Short Bruza Associates, PC, (405) 840-2931
ANY VARIANCE OR MODIFICATION…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .