This document is an amendment to a solicitation for a federal contract. The amendment extends the bid submission deadline from June 19, 2020 at 11:00 AM to July 6, 2020 at 9:00 AM, and extends the bid opening from 30 minutes to 60 minutes after submission. It also announces an additional pre-bid site visit on June 22, 2020 at 1:00 PM at the McMillan Water Treatment Plant in Washington, DC, with requirements for attendees to register in advance and comply with COVID-19 safety protocols including social distancing, cloth face coverings, and temperature screening. The solicitation, number W912DR20B0016, is for work related to the McMillan Backwash Discharge to Sewer and is issued by the Department of the Army Corps of Engineers Baltimore District.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT NO. 0002 TO ADVERTISED IFB W912DR-20-B-0016
EFFECTIVE DATE: June 12. 2020 PAGE 1 OF 5 PAGES
SOLICITATION:
1. Section 00 21 13 – Instructions to Bidders: REVISE as follows:
a. BID SUBMISSION TIME: REPLACE “11:00AM EST on 19 JUN 2020” with “9:00AM EST on 06 JUL 2020”
b. Bid Opening: REPLACE “Bids will be opened within 30 minutes after the time for bid submissions noted above. This 30 minute delay...” with “Bids will be opened within 60 minutes after the time for bid submissions noted above. This 60 minute delay…”
c. BID OPENING TIME: REPLACE “12:00PM EST on 19 JUN 2020” with “10:00AM EST on 06 JUL 2020”
d. ADDITIONAL SITE VISIT: “Another pre bid site visit will be held at 1300 hrs. on June 22, 2020 at the McMillan Water Treatment Plant (38.923445, -77.012278) located at 2500 First Street NW, Washington, DC 20001. Individuals interested in attending the site visit MUST submit their Name, Company Name, Date of Birth, Driver's License Number and issuing State to Nathan Cole by email (nathan.h.cole@usace.army.mil) no later than 2:00 p.m. on the business day before the site visit in order to be admitted to the site. Upon arriving for the site visit, individuals will be required to show their Driver's License. Individuals who do not have a driver's license will need to submit the information from a government issued ID (State or Federal) and be prepared to show that ID upon arrival.
In response to COVID-19 Pandemic and the requirements for social distancing, the Washington Aqueduct facilities are closed to everyone except employees, unless authorized in advance. For those authorized entry onto Washington Aqueduct property for this site visit, the following health and safety precautions will be adopted:
• No more than two employees from an individual company will be permitted to attend this site visit.
• All participants shall maintain a 6 foot minimum distance from Government personnel at all times.
• All persons entering Government property are to provide and wear cloth face coverings meeting the CDC guidelines at all times.
• All persons entering Government property must consent to temperature screening. A temperature reading of <100.4 degrees Fahrenheit is the criterion for participation in this site visit
• Hand sanitizer and/or wipes will be made available for participants.
EFFECTIVE DATE: June 12. 2020 PAGE 2 OF 5 PAGES
SPECIFICATIONS:
2. Section 02 41 00, Section 1.5 AVAILABILITY OF WORKS AREAS: REVISE as follows:
a. REPLACE DATE column information for Final Mixing Chamber Modifications with the following: "As required to comply with the construction sequencing requirements of specification Section 01 05 00."
b. ADD a horizontal line to the table to separate the entries for Spent Wash Water Channel Modification (Filter Building) from the entries for West Settled Water (Filter Influent) Channel Modifications.
c. REPLACE DATE column information for Spent Wash Water Channel Modification (Filter Building) with the following: "As required to comply with the construction sequencing requirements of specification Section 01 05 00.”
d. REPLACE DATE column information for West Settled Water (Filter Influent) Channel Modifications with the following: "As required to comply with the construction sequencing requirements of specification Section 01 05 00.”
3. Section 03 11 13.00 10, Paragraph 2.2.1: ADD the following at the end of paragraph 2.2.1:
“Form Liners:
1. Material: Elastomeric, FRP, ABS, or PVC.
2. Manufacturing Tolerance: Overall dimensions within 0.125 inch at time of manufacture.”
4. Section 03 11 13.00 10, Paragraph 3.1.d: ADD the following new text after paragraph 3.1.c:
“3.1.d. Form Liner Forms:
1. Prepare forms as recommended by manufacturer.
2. Provide liners in full sheets and locate seams as shown on approved Shop Drawings.
3. Anchor liners to formwork as recommended by liner manufacturer.
4. Clean form liner after each use and use only form release agents approved by form liner manufacturer."
5. Section 03 11 13.00 10, Paragraph 3.2.3: ADD the following at the end of paragraph 3.2.3:
“Forms Supporting Form Liners:
1. Construct to structurally withstand deflection, movement, leakage, high hydraulic pressures resulting from rapid filling and heavy-high frequency vibration.
2. Lay out form joints and ties in uniform pattern, unless otherwise shown.
Form Liner Installation:
1. Protect form liners from extended exposure to sunlight and from high surface temperatures during installation.
EFFECTIVE DATE: June 12. 2020 PAGE 3 OF 5 PAGES
2. Handle, cut, and install form liners in accordance with form liner manufacturer’s instructions and recommendations.
3. Place form liners with level and square, unless otherwise noted and in accordance with specified patterns and joints.
4. Maintain required concrete cover between form liner and steel reinforcement.”
6. Section 03 30 00.00 10, Paragraph 1.4.4.a: REPLACE text with the following:
"1.4.4.a Construct one panel."
7. Section 05 50 13, Paragraph 2.9: CHANGE the first sentence of Paragraph 2.9 to read “Type 304 stainless steel welded mesh with 2” diamond pattern square openings x 0.188-inch wire with U-shaped edging along four sides.”
8. Section 35 20 16.27, Paragraph 2.3.g.1: REPLACE with the following:
“ 2.3.g.1. The hydraulic tubing will be of the rigid type, with O.D. as recommended by gate manufacturer, manufactured from Type 316 stainless steel. All couplings shall be SWAGELOK quick connect type manufactured from Type 316 stainless steel. The hydraulic tubing anchoring system, the mounting rails and support kits shall be fabricated from Type 316 stainless steel."
9. Section 35 20 16.27, Paragraph 2.3.i.1: ADD the following at the end of the paragraph:
"Alternatively, adhesive anchors may be used if recommended by the gate manufacturer."
10. Section 35 20 16.27, Paragraph 2.3.j.5: REPLACE the paragraph with the following:
"2.3.j.5: Provide gasket between the gate frame and the concrete wall to seal installation. Gasket shall be ½ inch thick, neoprene type, factory-installed on the flushing gate. Gate manufacturer shall be responsible for coordinating with the Contractor on any special concrete finishes or plumbness or straightness tolerances required to ensure a proper seal between the concrete wall and the gates.
Contractor shall include all costs associated with any special finishes or tolerances in their base bid."
11. Section 40 05 13, Supplement 1d, Piping Schedule: REVISE as follows:
ADD the following new row of information: Under column heading Service: ADD "Ammonia";
Under column heading Size (inches): ADD "1"; Under column heading Material: ADD "PVC";
Under column heading Installation: ADD "Buried"; Under column headings Test Pressure (psig) and Type: ADD "100(H)"; and Under column heading Operating Pressure (psig) : ADD "25".
DRAWINGS:
12 Plate No. 1: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
EFFECTIVE DATE: June 12. 2020 PAGE 4 OF 5 PAGES
13. Plate No. 6: Delete this sheet, as originally issued, and substitute therefore the attached like
14. Plate No. 9: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
15. Plate No. 18: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
16. Plate No. 19: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
17. Plate No. 21: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
18. Plate No. 25: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
19. Plate No. 28: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
20. Plate No. 29: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
21. Plate No. 37: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
22. Plate No. 38: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
23. Plate No. 39: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
24. Plate No. 40: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
25. Plate No. 42: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
26. Plate No. 43: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
27. Plate No. 44 Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
28. Plate No. 45: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
29. Plate No. 46: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
30 Plate No. 51: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
31. Plate No. 52: Delete this sheet, as originally issued, and substitute therefore the attached like-
EFFECTIVE DATE: June 12. 2020 PAGE 5 OF 5 PAGES
32. Plate No. 71: Delete this sheet, as originally issued, and substitute therefore the attached like-
33. Plate No. 72: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
34. Plate No. 73: Delete this sheet, as originally issued, and substitute therefore the attached like-numbered sheet with change #2, dated 6/2020
35. Plate No. 75: Delete this sheet, as originally issued, and substitute therefore the attached like-
GENERAL:
36. Pre-Proposal Site Visit: Attached for information only is the sign in sheet for the Pre-Bid Site Visit dated 11 JUN 2020.
ATTACHMENTS:
1. Revised Drawing Plates 1, 6, 9, 18, 19, 21, 25, 28, 29, 37, 38, 39, 40, 42, 43, 44, 45, 46, 71, 72, 73,
2. 11 JUN 2020 Prospective Bidders Sign-in Sheet
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-D-3D-101.rvt 6/10/2020 5:32:36 PM
NONE
COVER SHEET , LOCATION AND
VICINITY MAPS
AND INDEX TO DRAWINGS
GENERAL
70.24-2- 1
G-001NOV 2019
MACARTHUR
TO DULLES
AIRPORT
N
VICINITY MAP
WASHINGTON AQUEDUCT
EXIT 9
EXIT 12
V I R G I N I A
FAIR
FAX C
O, V A
ARLIN
GTO
N C O, V
A
MONTG
OMERY C
O, M D
W
ESTE
RN A
VE
SOUTHERN A
VE.
PRIN
CE G
EORGES C
O, M
D
POTOMAC
RIVER
MD
VA
EXIT 40
EXIT 38
EXIT 35
EXIT 41
A R L I N G T O N
W A S H I N G T O N D. C.
OTOMAC
R
IVER
ANACOSTIA
RIV
ER
PRINCE GEORGES CO, MD
EASTERN AVE
REAGAN
WASH.
NAT. AIRPORT
PENTAGON
US CAPITOL
WHITE
HOUSE
M A R Y L A N D
M O
NT
G
O M
ER
Y
CO
, M
D
PR
IN
CE
G
EO
RG
ES
C
O , M
D
EXIT 14
D
ULLES AIR
PO
R
T
AC
C
ESS R
O
AD
DALECARLIA
RESERVOIR
M
ACARTHUR
BLVD
LOUGHBORO RD
GOLDSBORO RD
MASS
AVE
BLVD
CABIN
JO
H
N
PKW
Y
CLARA BARTON
PKW
Y
AM
. L
EG
M
EM
. B R
G
EO
WASH
MEM.
PKWY
CANAL
RD
WARD
CIRCLE
NE
BR
AS
KA
A
VE
KE
Y
BR
WHITEHURST
FRWY
MASS
AVE
INDEP AVE
TH
S
T.
NORTH TO
BALTIMORE
EXIT 27
ROOSEVELT
MEM. BR
ARL. MEM.
BRIDGE
ROSSLYN
TH
S T.
BRID
GE
G . W
M.
PENN AVE
ANACOSTIA
TO
R
IC
HMOND,
VA
SOUSABR.
SCALE IN MILES
1/4 1/2 1 2 3
BE
LT
W
AY
CHAIN
BRID
GE
CAP
BELTWAY
CONST AVE
THOMAS
CIRCLE
1S T
ST
7T H
S T.
G
EO
R G
IA
A
VE
R. I.
AVE
COL. RD MICH AVE
HRVD ST
ES
VI
LL
E
EXIT 30EXIT 31
ITAL
GEORGIA
AV
E RD
TH
T.
McMILLAN
RESERVOIR
SCOTT
CIRCLE
U.S. ARMY CORPS OF ENGINEERS
5900 MACARTHUR BLVD., N.W.
WASHINGTON, D.C. 20016-2514
PHONE: 202-764-2753
P
COL
BENNING RD
B.W
WHITNEY
YOUNG MEM. BR.
PK
W
Y
C O
NNECTICUT AVE
C
AP
IT
AL
KENILW
ORTH
NEW YORK
AVE
AVE
FR
W
Y
P.
TO RICHMOND,
VA
ARIZ.
AVE
S.E. FRWY
McMILLAN WATER
TREATMENT PLANT
2500 FIRST ST., N.W.
WASHINGTON, D.C. 20001
PHONE: 202-762-0167
DALECARLIA WATER
TREATMENT PLANT
5900 MACARTHUR BLVD., N.W.
WASHINGTON, D.C. 20016
PHONE: 202-764-2753
WASHINGTON AQUEDUCT
MCMILLAN WATER TREATMENT PLANT, WASHINGTON, D.C.
MCMILLAN BACKWASH DISCHARGE
TO SEWER
VOLUME 2 - DRAWINGS
ORIGINAL DOCUMENTS
NOVEMBER 2019
INDEX OF DRAWINGS
LOCATION MAP
N
FILTER BLDG
BACKWASH
EQUALIZATION
BASIN
M C M
I L L A N
R E S E R V O I R
CHEMICAL BLDG
ST
T
R E
E T
M I C H I G A N
A V E N U E
NORTH
CLEARWELL
36 ELECTRICAL - FILTER AND CHEMICAL BUILDING MCC ONE-LINES AND ELEVATIONS M26 E-601
35 ELECTRICAL - FILTER AND CHEMICAL BUILDING PLAN M26 E-105
34 ELECTRICAL - FILTER AND CHEMICAL BUILDING AND DIVERSION BOX PLAN M26 E-104
33 ELECTRICAL - FILTER AND CHEMICAL BUILDING AND DIVERSION BOX PLAN M26 E-103
32 ELECTRICAL - FILTER AND CHEMICAL BUILDING GROUND FLOOR PARTIAL PLAN M26 E-102
31 ELECTRICAL - FILTER AND CHEMICAL BUILDING BASEMENT PARTIAL PLAN M26 E-101
30 BUILDING SERVICES - FILTER AND CHEMICAL BUILDING DIVERSION BOX PLANS AND... M26 M-101 29 PROCESS - FILTER AND CHEMICAL BUILDING DIVERSION BOX PLANS AND SECTIONS M26 D-104 28 PROCESS - FILTER AND CHEMICAL BUILDING FINAL MIXING CHAMBER PLANS AND... M26 D-103
27 PROCESS - FILTER AND CHEMICAL BUILDING FILTER GALLERY PLAN M26 D-102
26 PROCESS - FILTER AND CHEMICAL BUILDING BASEMENT PARTIAL PLAN M26 D-101
25 STRUCTURAL - FILTER AND CHEMICAL BUILDING DIVERSION BOX PLANS AND SECTIONS M26 S-101
M26-CHEMICAL BUILDING AND FILTER BUILDING
24 SITE - ELECTRICAL SITE SECTIONS ES103
23 SITE - ELECTRICAL DUCT BANK SECTIONS ES102
22 SITE - ELECTRICAL PLAN ES101
21 SITE - YARD PIPING PLAN DS101
YARD PIPING - SITE ELECTRICAL
20 CIVIL - PARTIAL SITE PLAN - SOUTH C-102
19 CIVIL - PARTIAL SITE PLAN - NORTH C-101
18 CIVIL - SITE PLAN DEMOLITION CD101
17 GEOTECHNICAL - SOIL BORING LOGS - BEB-02 B-102
16 GEOTECHNICAL - SOIL BORING LOGS - BEB-01 B-101
15 GEOTECHNICAL - SOIL BORING LOCATION PLAN B-100
SITE
14 GENERAL - INSTRUMENTATION AND CONTROLS LEGEND G-014
13 GENERAL - ELECTRICAL LEGEND G-013
12 GENERAL - ELECTRICAL LEGEND AND ABBREVIATIONS G-012
11 GENERAL - BUILDING SERVICES LEGENDS G-011
10 GENERAL - PROCESS LEGEND G-010
9 GENERAL - BEAM AND COLUMN SCHEDULE G-009
8 GENERAL - STRUCTURAL SPECIAL INSPECTIONS SHEET 2 OF 2 G-008
7 GENERAL - STRUCTURAL SPECIAL INSPECTIONS SHEET 1 OF 2 G-007
6 GENERAL - STRUCTURAL NOTES G-006
5 GENERAL - ARCHITECTURAL SCHEDULES G-005
4 GENERAL - ARCHITECTURAL AND STRUCTURAL LEGENDS, NOTES AND LIFE SAFETY PLANS G-004
3 GENERAL - CIVIL AND YARD PIPING LEGENDS G-003
2 GENERAL - ABBREVIATIONS AND GENERAL NOTES G-002
1 GENERAL - COVER SHEET AND INDEX TO DRAWINGS G-001
GENERAL
PLATE
NO. TITLE BUILDING
ID
SHEET
NO.
83 STANDARD DETAILS - INSTRUMENTATION AND CONTROL DI501
82 STANDARD DETAILS- ELECTRICAL DE501
81 STANDARD DETAILS - BUILDING SERVICES DM502
80 STANDARD DETAILS - BUILDING SERVICES DM501
79 STANDARD DETAILS - PROCESS DD502
78 STANDARD DETAILS - PROCESS DD501
77 STANDARD DETAILS - ARCHITECTURAL DA502
76 STANDARD DETAILS - ARCHITECTURAL DA501
75 STANDARD DETAILS - STRUCTURAL DS505
74 STANDARD DETAILS - STRUCTURAL DS504
73 STANDARD DETAILS - STRUCTURAL DS503
72 STANDARD DETAILS - STRUCTURAL DS502
71 STANDARD DETAILS - STRUCTURAL DS501
70 STANDARD DETAILS - CIVIL DC501
STANDARD DETAILS
69 P&ID - BACKWASH EQUALIZATION BASIN AND PUMPS M29-M30 I-601
PROCESS AND INSTRUMENTATION DIAGRAMS (P&IDs)
68 ELECTRICAL - CONTROL DIAGRAMS M29-M30 E-604
67 ELECTRICAL - PANEL SCHEDULES AND LUMINAIRE SCHEDULE M29-M30 E-603
66 ELECTRICAL - CABLE BLOCK DIAGRAMS M29-M30 E-602
65 ELECTRICAL - CABLE BLOCK DIAGRAMS M29-M30 E-601
64 ELECTRICAL - LIGHTING PLANS AT ELEVATION 171 AND ROOF M29-M30 EL102
63 ELECTRICAL - FLOW METER CONTROL VALVE ROOM LIGHTING PLAN AND SECTION M29-M30 EL101
62 ELECTRICAL - POWER PLAN AT ELEVATION 171 AND SECTIONS M29-M30 EP102
61 ELECTRICAL - FLOW METER CONTROL VALVE ROOM POWER PLANS M29-M30 EP101
60 ELECTRICAL - OVERALL PLAN M29-M30 E-101
59 BUILDING SERVICES - SEQUENCE OF OPERATIONS AND SCHEDULES M29-M30 M-103
58 BUILDING SERVICES - ROOF PLAN AND SECTIONS M29-M30 M-102
57 BUILDING SERVICES - PLANS AND SECTION M29-M30 M-101
56 PROCESS - SECTIONS M29-M30 D-201
55 PROCESS - FLOW METER CONTROL VALVE ROOM PLANS M29-M30 D-102
54 PROCESS - FLUSH STORAGE CHAMBER AND INLET DISTRIBUTION CHANNEL PLANS &... M29-M30 D-101
53 PROCESS - OVERALL PLAN AND SECTION M29-M30 D-100
52 ARCHITECTURAL - ELEVATIONS M29-M30 A-302
51 ARCHITECTURAL - ELEVATIONS M29-M30 A-301
50 ARCHITECTURAL - SECTIONS M29-M30 A-202
49 ARCHITECTURAL - SECTIONS M29-M30 A-201
48 ARCHITECTURAL - PLAN AT ELEVATION 171 AND ROOF PLAN M29-M30 A-102
47 ARCHITECTURAL - PLANS AT ELEVATION 143 AND 164 M29-M30 A-101
46 STRUCTURAL - DETAIL AND SECTION M29-M30 S-501
45 STRUCTURAL - SECTIONS M29-M30 S-204
44 STRUCTURAL - SECTIONS M29-M30 S-203
43 STRUCTURAL - SECTIONS M29-M30 S-202
42 STRUCTURAL - SECTIONS M29-M30 S-201
41 STRUCTURAL - SECTIONS M29-M30 S-200
40 STRUCTURAL - ROOF AND BACKWASH WASTE CONNECTION CONDUIT PLAN M29-M30 S-103
39 STRUCTURAL - UPPER LEVEL PLANS M29-M30 S-102
38 STRUCTURAL - LOWER LEVEL PLANS M29-M30 S-101
37 STRUCTURAL - OVERALL PLAN M29-M30 S-100
BACKWASH EQUALIZATION BASIN AND PUMP STATION
PLATE
NO. TITLE BUILDING
ID
SHEET
NO.
REFERENCE DRAWINGS
1 EXISTING SLOW SAND FILTERS
NO. INFORMATION SHOWN
2 EXISTING SLOW SAND FILTERS
3 EXISTING RAMP AND OUTDOOR STAIR
4 EXISTING CORNER STONES NEAR FINAL MIXING CHAMBER
5 EXISTING MANHOLE 100
6 EXISTING AMMONIA PIPES
APPROVED:
SEAL
A/E PRINCIPAL
7 EXISTING SLOW SAND FILTERS
8 EXISTING RETAINING WALL NEAR FINAL MIXING CHAMBER
1 06/2020 AMENDMENT 0001 GP
2 06/2020 AMENDMENT 0002 GP
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-S-3D-101.rvt 6/10/2020 4:55:02 PM
NONE
STRUCTURAL
NOTES
GENERAL
70.24-2- 6
G-006NOV 2019
W=6.0FT
SNOW
DRIFT
6.
7.
SNOW
46 PSF
4.
5.
22 PSF
GENERAL INFORMATION
FOUNDATIONS
FORMWORK, SHORING AND BRACING
SPECIAL INSPECTION, OBSERVATIONS AND TESTING
DESIGN CRITERIA
CONCRETE
CONCRETE REINFORCING
1.
2.
3.
4.
5.
6.
7.
L/240 L/360
2.
1.
1.
2.
3.
= 25 PSF
= C = 1.0 = 1.0 = 1.1
APPLICABLE CODE: 2015 INTERNATIONAL BUILDING CODE (IBC), AS MODIFIED BY UNIFIED FACILITIES CRITERIA (UFC) 1-200-01, DOD BUILDING CODE (GENERAL BUILDING REQUIREMENTS) AND UFC- 3-301-01, STRUCTURAL ENGINEERING..
ROOF LOADS:
GROUND SNOW LOAD, Pg
TERRAIN CATEGORY
Ce Ct I FLAT ROOF SNOW LOAD, Pf
STRUCTURE HAS NOT BEEN DESIGNED FOR REDUCED ROOF LIVE LOADS IN ACCORDANCE
WITH THE IBC.
TOTAL LOAD
LIVE LOAD
WHERE L IS THE MEMBER'S SPAN LENGTH
300 PSF
300 PSF
100 PSF
FLOOR LIVE LOADS:
PROCESS FLOOR
ELECTRICAL ROOM
CORRIDORS, EXITS, STAIRS
WALKWAYS AND ELEVATED PLATFORMS
COLUMNS, FOOTINGS, AND FLOOR FRAMING MEMBERS HAVE NOT BEEN DESIGNED FOR REDUCED
LIVE LOADS IN ACCORDANCE WITH THE BUILDING CODE.
DEFLECTION CRITERIA FOR FLOOR FRAMING MEMBERS:
INDUSTRIAL/PROCESS FLOOR (ELECTRICAL/ MECHANICAL ROOMS, STORAGE, PLATFORM, ETC):
TOTAL LOAD
LIVE LOAD
WHERE L IS THE MEMBER'S SPAN LENGTH
= C
= +/- 0.18
= III
= 1.0
WIND LOAD:
EXPOSURE
RISK CATEGORY
= III
= B = 1.25
MAPPED SPECTRAL RESPONSE ACCELERATIONS
SS
DESIGN SPECTRAL RESPONSE ACCELERATIONS
SDS
SD1
SEISMIC DESIGN CATEGORY
STRUCTURES HAVE BEEN ANALYZED USING THE EQUIVALENT LATERAL FORCE PROCEDURES OF
ASCE 7-10.
LATERAL FORCE-RESISTING SYSTEM
1.
2.
3.
7.
EXCAVATIONS SHALL BE SHORED TO PREVENT SUBSIDENCE OR DAMAGE TO ADJACENT EXISTING
STRUCTURES, STREETS, UTILITIES, ETC.
ALL FOUNDATION SLABS, SLABS-ON-GRADE AND WALL AND COLUMN FOUNDATIONS, UNLESS NOTED
ALL FOUNDATION BEARING SURFACES SHALL BE OBSERVED BY A GEOTECHNICAL ENGINEER OR HIS DESIGNEE PRIOR TO PLACEMENT OF FORMING OR REINFORCING STEEL THE OBSERVATION SHALL VERIFY THAT THE ACTUAL EXPOSED SUBGRADE IS AS ANTICIPATED BY THE SITE SPECIFIC BORINGS, TEST PITS, TESTING AND DATA REPORTS.
NO BACKFILL SHALL BE PLACED BEHIND WALLS UNTIL THE WALLS HAVE ATTAINED 100 PERCENT OF IT'S
NO BACKFILL SHALL BE PLACED BEHIND CANTILEVERED, FREE TOP WALLS UNTIL THE CONCRETE HAS
ATTAINED100 PERCENT OF ITS SPECIFIED COMPRESSIVE STRENGTH.
STRUCTURES SHOWN ON THE DRAWINGS HAVE BEEN DESIGNED FOR STABILITY UNDER FINAL CONDITIONS ONLY EXCEPT AS NOTED. DESIGN SHOWN DOES NOT INCLUDE NECESSARY COMPONENTS OR EQUIPMENT
TEMPORARY SHORING SHALL REMAIN IN PLACE UNTIL ELEVATED CONCRETE FLOOR OR SLABS HAVE REACHED 80 PERCENT OF THE 28 DAY DESIGN STRENGTH AS DETERMINED BY CYLINDER BREAKS.
GENERAL SNOW DRIFT DIAGRAMS FOR AREAS WITH INCREASED
DRIFT LOADS. MAXIMUM DRIFT LOADS OCCURS ON ROOF ALONG
ALL PARAPETS AND WALLS.
100 PSF
SPECIAL INSPECTION IS REQUIRED IN ACCORDANCE WITH IBC SECTIONS 109 AND 1704 AS INDICATED IN THE
STATEMENT OF SPECIAL INSPECTIONS PLAN ON DRAWINGS 01-G-006 TO 01-G-008.
SPECIFIED CONCRETE TESTING DURING CONSTRUCTION WILL BE CONTRACTOR FURNISHED AND OWNER APPROVED.
SPECIFIED LABORATORY TEST MIXES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
STRUCTURAL OBSERVATIONS IS NOT REQUIRED FOR THIS PROJECT.
SPECIFIED COMPRESSIVE STRENGTH AND TOP SUPPORTING SLAB’S CONCRETE HAVE ATTAINED 80 PERCENT
OF THEIR SPECIFIED COMPRESSIVE STRENGTH UNLESS OTHERWISE NOTED.
1.
2.
3.
L/240 L/360
SNOW LOAD L/360
WIND IMPORTANCE FACTOR
= 0.12 g
= 0.128 g
8.
ASCE 7 METHOD
= ENCLOSED
SEISMIC LOAD:
USE UTMOST CARE TO AVOID DAMAGE TO EXISTING STRUCTURES WHEN PERFORMING EXCAVATING
ACTIVITIES.
= 22.0 PSF MIN
ROOF LIVE LOAD
EQUIVALENT 2.0 FEET OF SOIL
30 INCHES
A.
B.
C.
VERTICAL SURCHARGE:
DESIGN GROUND WATER ELEVATION:
FROST DEPTH:D.
= 90 MPH
ENCLOSURE CATEGORY
INTERNAL PRESSURE COEFFICIENT
= 0.051 g
= 0.08 g
SOIL DESIGN PARAMETERS:
145 FT
FOR ABBREVIATIONS NOT LISTED, SEE ASME Y14.38 “ABBREVIATIONS AND ACRONYMS: PUBLICATION
AS DISTRIBUTED BY THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME).
DESIGN DETAILS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS OCCURRING
THROUGHOUT THE PROJECT, WHETHER OR NOT THEY ARE INDIVIDUALLY CALLED OUT.
DETAILING AND DIMENSIONS OF EXISTING STRUCTURES SHOWN ARE BASED ON AS-BUILT DESIGN DRAWINGS, AND DO NOT NECESSARILY REPRESENT THE AS-CONSTRUCTED CONDITIONS. THE CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND DETAILING OF THE EXISTING STRUCTURES PRIOR TO FABRICATION OF ADJACENT FRAMING OR CONNECTIONS OR SUPPORTS THAT ARE AFFECTED BY THE EXISTING STRUCTURE.
VERIFY FINAL OPENING DIMENSIONS IN WALLS, SLABS, AND DECKS WITH OTHER DISCIPLINE DRAWINGS
PRIOR TO CONSTRUCTION OF THESE ELEMENTS.
FOR NUMBER, TYPE, SIZE, ARRANGEMENT, AND/OR LOCATION OF EQUIPMENT PADS SEE OTHER DISCIPLINE DRAWINGS. COORDINATE WITH EQUIPMENT SUPPLIER PRIOR TO PLACING SLABS, WALLS AND FOUNDATIONS.
COORDINATE PIPING OPENINGS WITH OTHER DISCIPLINE DRAWINGS.
STRUCTURAL MEMBERS SHALL NOT BE CUT OR MODIFIED FOR PIPES, DUCTS, ETC, UNLESS SPECIFICALLY
DETAILED OR APPROVED IN WRITING BY THE ENGINEER.
VISITS TO THE JOB SITE BY THE ENGINEER TO OBSERVE THE CONSTRUCTION DO NOT IN ANY WAY MEAN THAT ENGINEER IS GUARANTOR OF CONSTRUCTOR’S WORK, NOR RESPONSIBLE FOR THE COMPREHENSIVE
OR SPECIAL INSPECTIONS, COORDINATION, SUPERVISION, OR SAFETY AT THE JOB SITE.
FOR STABILITY OF THE STRUCTURES DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ALL
SCAFFOLDING, FORMWORK, AND OTHER WORK AIDS REQUIRED TO SAFELY PERFORM THE WORK SHOWN.
WORK RELATING TO CONSTRUCTION ERECTION METHODS, BRACING, SHORING, RIGGING, GUYS,
6.
7.
BAR SIZE
LAP SPLICE LENGTH
TOP BAR
OTHER BAR
1'-4" 1'-4"
2'-0" 1'-7"
3'-0" 2'-4"
4'-0" 3'-1"
5'-10" 4'-6"
6'-8" 5'-2"
7'-7" 5'-10"
8'-6" 6'-7"
9'-5" 7'-3"
#3 #4 #5 #6 #7 #8 #9
TOP BAR
OTHER BAR
1'-4" 1'-4"
2'-5" 1'-10"
3'-6" 2'-9"
4'-0" 3'-1"
5'-0" 3'-10"
6'-2" 4'-9"
7'-5" 5'-8"
1'-6" 1'-4" 1'-7"
2'-0"
TOP BAR
OTHER BAR
1'-0" 1'-0"
1'-7" 1'-3"
2'-4" 1'-9"
TOP BAR
OTHER BAR
1'-0" 1'-0"
2'-5" 1'-10"
3'-6" 2'-9"
4'-0" 3'-1"
4'-6" 3'-10"
5'-1" 4'-9"
5'-7" 5'-8"1'-3"
1'-0" 1'-3" 1'-7"
EMBEDMENT LENGTH
3'-1" 4'-6" 5'-2" 5'-10" 6'-7" 7'-3"
1'-5" 2'-1" 2'-5" 3'-0" 3'-8" 4'-5"
CONCRETE DESIGN STRENGTH = 4,000 PSI GRADE 60 REINFORCING STEEL
SPACING<6"
SPACING>6"
SPACING<6"
SPACING>6"
#10 #11
REINFORCEMENT BENDS AND LAPS, UNLESS OTHERWISE NOTED, SHALL SATISFY THE FOLLOWING
MINIMUM REQUIREMENTS:
TOP BARS SHALL BE DEFINED AS ANY HORIZONTAL BARS PLACED SUCH THAT MORE THAN 12
INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR IN ANY SINGLE POUR.
HORIZONTAL WALL BARS ARE CONSIDERED TOP BARS.
WHERE 3000 PSI CONCRETE IS USED, INCREASE ABOVE LENGTHS BY 16 PERCENT
CD
R
BUILDING AT SOUTH OF BACKWASH BASIN
ROUGHEN AND CLEAN CONSTRUCTION JOINTS IN WALLS AND SLABS AS SPECIFIED PRIOR TO PLACING
ADJACENT CONCRETE.
THE CONTRACTOR SHALL COORDINATE PLACEMENT OF OPENINGS, CURBS, DOWELS, SLEEVES, CONDUITS, BOLTS AND INSERTS PRIOR TO PLACEMENT OF CONCRETE.
NO ALUMINUM CONDUIT OR PRODUCTS CONTAINING ALUMINUM OR ANY OTHER MATERIAL INJURIOUS
TO THE CONCRETE SHALL BE EMBEDDED IN THE CONCRETE.
CONDUIT SHALL NOT BE PLACED PARALLEL WITH BEAM OR COLUMN REINFORCEMENT UNLESS
SPECIFICALLY INDICATED IN DRAWINGS.
EQUIVALENT FLUID PRESSURES ABOVE AND BELOW GROUND WATER TABLE:
CLEARANCE FOR REINFORCEMENT BARS, UNLESS SHOWN OTHERWISE, SHALL BE:
WHEN PLACED ON GROUND: 3”
INTERIOR, DRY, HUMIDITY CONTROLLED AREAS:
WALLS, SLABS AND JOISTS 3/4"
BEAM STIRRUPS AND COLUMN TIES 1.5”
ALL OTHER CONCRETE SURFACES 2”
REFER TO WALL CORNER AND WALL INTERSECTION REINFORCING DETAIL 0330-003. WALL CORNER REINFORCING SIZES AND SPACINGS SHALL BE AS SHOWN ON THE DRAWINGS AND REFERENCED TO THIS DETAIL. TYPICAL HORIZONTAL WALL REINFORCING SHALL LAP WITH THE CORNER HORIZONTAL
REINFORCING.
90 DEGREE BENDS, UNLESS OTHERWISE SHOWN, SHALL BE ACI 318 STANDARD HOOKS.
WALL CORNER AND WALL INTERSECTION REINFORCEMENT BARS SHALL BE CONTINUOUS AROUND CORNERS AND THROUGH COLUMNS OR PILASTERS. REINFORCEMENT SHALL BE EXTENDED INTO CONNECTING WALLS AND LAPPED ON THE OPPOSITE FACE OF THE CONNECTING WALLS, AS INDICATED IN DETAIL 0330-003.
LAP VERTICAL WALL BARS WITH DOWELS FROM BASE SLABS AND EXTEND INTO TOP FACE OF ROOF SLABS AND LAP WITH TOP SLAB REINFORCEMENT. PROVIDE A MINIMUM OF FOUR FULL HEIGHT VERTICAL BARS WITH MATCHING DOWELS AT WALL ENDS, CORNERS AND INTERSECTIONS WITH SIZE TO MATCH
TYPICAL VERTICAL REINFORCING STEEL SHOWN OR REQUIRED BY NOTES ABOVE.
LOCATE ELEVATED SLAB AND BEAM TOP BAR SPLICES AT MIDSPAN AND BOTTOM BAR SPLICES AT SUPPORTS.
5.
6.
7.
9.
10.
12.
13.
14.
FOR EXTRA REINFORCING AROUND OPENINGS, SEE DETAIL 0330-002.
FOR WALL BASE CONSTRUCTION JOINT, SEE DETAIL 0315-153, 0330-004 AND 0330-005.
FOR WALL VERTICAL CONSTRUCTION JOINT LOCATION, SEE DETAIL 0315-131.
DIRECTIONAL DESIGN METHODS
SITE CLASS
ORDINARY REINFORCED CONCRETE SHEAR WALLS
CD
R
GROUND SUPPORTED REINFORCED CONCRETE TANKS WITH NON-SLIDING BASE
= 4 = 4
= 2
DEFLECTION CRITERIA FOR ROOF FRAMING MEMBERS:
DEFLECTION LIMITS OF CONCRETE ELEMENT IN ACCORDANCE WITH ACI 318 AND ACI 350.
DEFLECTION LIMITS OF CONCRETE ELEMENT IN ACCORDANCE WITH ACI 318 AND ACI 350.
COMPONENT AND CLADDING WALL ELEMENTS (WINDOWS, DOORS, LOUVERS, SIDING, ETC FOR
STRUCTURES UNDER 60 FEET IN HEIGHT)
6" 8"
10" 12"
#4@12"
#4@12" #5@12"
#5@12"
CENTERED
CENTERED
EACH FACE
EACH FACE
LOCATIONREINF EACH WAY
MINIMUM REINFORCING FOR ALL CONCRETE WALLS AND SLABS SHALL BE AS FOLLOWS:
PROVIDE LARGER SIZES AND MORE REINFORCING IN SECTIONS OF CONCRETE WHERE REQUIRED BY
THE DETAILS ON THE DRAWINGS OR BY THE SPECIFICATIONS.
THICKNESS
1.
2.
3.
4.
THE LOADS LISTED ON THIS DRAWING ARE GENERAL AND APPLY AS APPLICABLE TO ALL STRUCTURES.
TRIBUTARY
AREA
NEGATIVE POSITIVE
ZONE 2 ZONE 3
10 FT2
20 FT2
50 FT2
100 FT2
PRESSURE AT WALL ELEMENT PER ASCE7 FIGURE 6-11A (PSF)
30.1
25.5
-30.1 -28.3
-25.5
PRESSURE AT ROOF ELEMENT PER ASCE7 FIGURE 6-11B (PSF)
-57.8-34.5 -33.6 -32.4 -31.5
ZONE 1
-57.8 -51.7 -43.5 -37.4
-43.5 -51.7
-37.4 12.0 13.1
11.1
31.5-31.5
26.9-26.9
23.7-23.7
28.3
14.0 31.5
26.9 28.3 30.1
ZONE 1
70 PSF
BACKWASH BASIN
1.
2.
3.
4.
5.
5000 PSI
28-DAY CAST-IN-PLACE CONCRETE STRENGTHS:
TYPICAL UNO: CLASS 5000F3S1P2C2
CONTINUOUS WATERSTOP AS SPECIFIED SHALL BE INSTALLED IN ALL CONSTRUCTION JOINTS IN WATER HOLDING BASINS, CHANNELS, AND BELOW GRADE STRUCTURES, EXCEPT WHERE SPECIFICALLY NOTED
OTHERWISE.
CONSTRUCTION JOINTS INDICATED ARE SUGGESTED LOCATIONS. CONTRACTOR MAY
REVISE LOCATIONOF JOINTS, SUBJECT TO SPECIFIED REQUIREMENTS. ADDITIONAL CONSTRUCTION JOINT LOCATIONS, INCLUDING ADDITIONAL REQUIRED FOR CONSTRUCTION, SHALL BE SUBMITTED FOR REVIEW BY ENGINEER.
OTHERWISE, SHALL BEAR ON 6 INCHES OF COMPACTED GRANULAR FILL.
REINFORCING STEEL:
TYPICAL ASTM A615, GRADE 60
WELDED ASTM A706, GRADE 60 (WELDING IS ONLY PERMITTED
WITH WRITTEN PERMISSION OF ENGINEER)
FABRICATION AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH CRSI MSP-1 "MANUAL OF STANDARD PRACTICE" AND ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE".
FOR REINFORCED CONCRETE FRAME MEMBERS AND DESIGNATED BOUNDARY ELEMENTS OF CONCRETE
SHEAR WALL STRUCTURES, REINFORCING STEEL SHALL MEET THE FOLLOWING REQUIREMENTS:
A. ACTUAL YIELD STRENGTH BASED ON MILL TESTS SHALL NOT EXCEED SPECIFIED
YIELD STRENGTH BY MORE THAN 18,000 PSI. (RETESTS SHALL NOT EXCEED THIS
VALUE BY MORE THAN AN ADDITIONAL 3000 PSI.)
B. RATIO OF HTE ACTUAL ULTIMATE TENSILE STRESS TO ACTUAL TENSILE YIELD
STRENGTH SHALL NOT BE LESS THAN 1.25.
4.
5.
6.
MONORAIL HOIST LOADS:
VERTICAL IMPACT FACTOR:
LATERAL FORCE
LONGITUDINAL FORCE:
= 1.25
= 20% OF RATED CAPACITY PLUS
WEIGHT OF HOIST AND TROLLEY
= 10% OF MAXIMUM WHEEL LOAD
= 120 MPH
NOMINAL DESIGN WIND SPEED:
ULITMATE DESIGN WIND SPEED:
= 2
SEISMIC IMPORTANT FACTOR I
IBC 2015
NUMBERS
REFER TO GEOTECHNICAL DESIGN REPORT BY JACOBS ENGINEERING, DATED JULY 26 2019
THE GEOTECHNICAL DESIGN REPORT IS PROVIDED FOR INFORMATION ONLY.
65 PSF/FT ABOVE GROUND WATER 95 PSF/FT BELOW GROUND WATER
ZONE 2 & 3
TRIBUTARY
AREA
NEGATIVE POSITIVE
ZONE 5ZONE 4 ZONE 4 & 5
10 FT2
20 FT2
50 FT2
100 FT2
200 FT2
500 FT2
8.
WELDING
STRUCTURAL STEEL AND METAL FABRICATIONS
DEFERRED SUBMITTALS
1.
2.
3.
4.
WELDS SHALL CONFORM TO AMERICAN WELDING SOCIETY (AWS), LATEST EDITION:
D1.1, STRUCTURAL WELDING CODE – STEEL
D1.2, STRUCTURAL WELDING CODE – ALUMINUM
D1.3, STRUCTURAL WELDING CODE – SHEET STEEL
D1.4, STRUCTURAL WELDING CODE – REINFORCING STEEL
D1.6, STRUCTURAL WELDING CODE – STAINLESS STEEL
REPAIR WELDS FOUND DEFECTIVE IN ACCORDANCE WITH AWS D1.1 SECTION 5.26.
USE INTERMITTENT WELDS AT FIELD WELDS OF EMBED PLATES AND ANGLES TO AVOID
SPALLING OR
CRACKING OF THE EXISTING CONCRETE.
BUTT JOINT WELDS SHALL BE COMPLETE JOINT PENETRATION (CJP) UNLESS INDICATED
OTHERWISE.
A992
A36
A500, GRADE B
A53, GRADE B
A276
A325-N
A325-SC
F593, AISI TYPE 316, CONDITION CW
F1554, GR 36
F1554, GR 36 / A153
A307
F593, AISI TYPE 316, CONDITION CW
A307/A153
F468, ALLOY 2024-T4
ANY EQUIPMENT OR COMPONENT IN WHICH A TECHNICAL
SPECIFICATION REQUIRES SUBMITTAL OF EQUIPMENT
OR ANCHORAGE SYSTEM CALCULATIONS
ITEMSPECIFICATION
SECTION
ASTM B 308, ALLOY 6061-T6
1.
2.
3.
4.
6.
7.
STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING:
W-SHAPES
MISCELLANEOUS SHAPES INCLUDING
ANGLES, CHANNELS, PLATES, ETC.
SQUARE OR RECTANGULAR STEEL TUBING
STEEL PIPE
STAINLESS STEEL SHAPES
ALUMINUM SHALL CONFORM TO THE FOLLOWING ASTM STANDARDS:
STRUCTURAL SHAPES AND PLATES
STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN CONFORMANCE WITH THE AISC
MANUAL OF STEEL CONSTRUCTION, CURRENT EDITION, AND CURRENT OSHA STANDARDS
BOLTS SHALL BE HIGH STRENGTH BOLTS CONFORMING TO THE FOLLOWING EXCEPT WHERE
SPECIFICALLY INDICATED OTHERWISE:
UNLESS SHOWN OTHERWISE
SLIP CRITICAL
ANCHOR BOLTS (AB)
STAINLESS STEEL
STEEL
GALVANIZED STEEL
MACHINE BOLTS (MB)
STEEL
STEEL STAINLESS STEEL
GALVANIZED STEEL
ALUMINUM
ITEMS TO BE EMBEDDED IN CONCRETE SHALL BE CLEAN AND FREE OF OIL, DIRT AND PAINT.
NO HOLES OTHER THAN THOSE SPECIFICALLY DETAILED SHALL BE ALLOWED THROUGH
STRUCTURAL STEEL MEMBERS. NO CUTTING OR BURNING OF STRUCTURAL STEEL IS PERMITTED
WITHOUT THE APPROVAL OF THE ENGINEER
05 52 00 METAL RAILINGS
DEFERRED SUBMITTALS ARE THOSE PORTIONS OF THE DESIGN WHICH ARE NOT SUBMITTED AT THE TIME OF PERMIT APPLICATION AND WHICH ARE TO BE SUBMITTED TO THE PERMITTING AGENCY FOR
ACCEPTANCE PRIOR TO INSTALLATION OF THAT PORTION OF THE WORK.
THE FOLLOWING IS A LIST OF DEFERRED SUBMITTALS THAT ARE EXPECTED TO CONTAIN STRUCTURAL
CALCULATIONS OR SAFETY RELATED SYSTEM INFORMATION. PRIOR TO INSTALLATION OF THE
INDICATED STRUCTURAL ELEMENT, EQUIPMENT, DISTRIBUTION SYSTEM, OR COMPONENT OR ITS ANCHORAGE, THE CONTRACTOR SHALL SUBMIT THE REQUIRED CALCULATIONS AND SUPPORTING DATA
AND DRAWINGS FOR REVIEW AND ACCEPTANCE BY THE ENGINEER.
1.
2.
-30.1 -28.3
-25.5
-31.5
-26.9
-23.7
RISK CATEGORY
= D
4000 PSIELECTRIC DUCTBANK: CLASS 40000F1S1P0C1
4000 PSIFIBER REINFORCED CONCRETE FILL: CLASS CF00F1S1P0C1
CONSERVATIVELY USED R=2 AND CD =2 FOR DESIGN OF BOTH BUILDING AND BASIN.
BASE SHEAR = 2
SUBGRADE MODULUS:E.
TOP OF GRADE IS ASSUMED TO BE AT EL 169 FT TO THE NORTH AND SLOPES DOWN TO 164 FT
TO THE SOUTH IN THE CALCULATION OF SOIL LATERAL PRESSURE AT EXTERIOR WALLS.
F.
75 KCF
9. HYDROSTATIC LOAD: ASSUMED MAXIMUM WATER LEVEL AT EL 167 FT IN THE STRUCTURAL DESIGN.
8. FOR DETAILS REGARDING THE REQUIREMENTS FOR SOIL EXCAVATION, BACKFILL, FOUNDATION SUB-BASE MATERIALS AND FOUNDATION SUBGRADE PREPARATION REFER TO SPECIFICATION SECTION 31 23 16
EXCAVATION AND FILL.
S1
5. POST INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS SHALL BE 316 STAINLESS STEEL ADHESIVE ANCHORS AT WET OR EXTERIOR
APPLICATION AND AT ALUMINUM MEMBERS. USE HOT-DIP GALVANIZED OR ZINC PLATED STEEL EXPANSION
ANCHORS AT INTERIOR DRY APPLICATIONS.
2. POST-INSTALLED ANCHOR SYSTEM USED IN CONCRETE SHALL BE APPROVED BY ICC EVALUATION
SERVICES REPORT OR EQUIVALENT FOR USE IN CRACKED CONCRETE AND FOR SHORT-TERM AND
LONG-TERM LOADS INCLUDING WIND AND EARTHQUAKE.
1 06/2020 AMENDMENT 0002 GP
GENERAL NOTES
LOCATE ALL EXISTING REINFORCEMENT VIA GROUND
PENETRATING RADAR AND SUBMIT RESULTS WITH PROPOSED
OPENING LOCATIONS TO ENGINEER OF RECORD FOR REVIEW
AND APPROVAL PRIOR TO CUTTING OR CORING EXISTING
CONCRETE STRUCTURES. FOR HOLES THAT ARE 6 INCHES IN
DIAMETER OR SMALLER ENGINEER MAY ALLOW CONTRACTOR
TO SHIFT OPENINGS TO AVOID REINFORCING.
1.
W W
DD
W
D
W
D
STANDARD 90°
BEND, ROTATE
AS REQD, TYP
TYPE 1 TYPE 2
TYPICAL SECTION
BEAM TYPES
TYPE 3 TYPE 4
BEAM REINFORCING DETAIL
STD 135°
BEND, TYP
SHEAR REINF
(TC)
(B) STOP AT FACE OF SUPPORT
(TC) (T) (S) (TC)
(B)
(BC)
CL SUPPORT, BEAM
IS DISCONTINUOUS
(BC)
(T)
TOP
BARS
(S) WHERE
REQUIRED,SEE
BEAM SCHEDULE SPLICE BC BARS
@ SUPPORT
SPLICE TOP CONT
BARS AND "S"
BARS AT
MIDSPAN
CLOSURE BARS, SAME SIZE
AND SPACING AS SHEAR
REINF
CL SUPPORT, BEAM IS CONTINUOUS
TC OR T REINF, PLACE TC
REINF @ STIRRUP CORNERS,
TC REINF SHOULD BE PLACED
IN UPPERMOST LAYER UNO
1.
2.
NOTES:
PLACE TOP (T & TC) AND BOTTOM (B & BC) BARS IN
MULTIPLE ROWS ONLY WHERE INDICATED IN SCHEDULE.
WHEN INDICATED IN BEAM SCHEDULE, SUBSTITUTE
CLOSED TIES
SHOWN
PROVIDE MINIMUM 1 - #5 CONTINUOUS AT EACH
CORNER OF STIRRUPS.
3.
(S) BARS
LAP LENGTH
DISCONTINUE SLAB
LONGITUDINAL REINF
@ BEAM, PLACE 3"
CLR OF BEAM, TYP
INTERIOR STIRRUPS,
REQUIRED IF INDICATED
IN BEAM SCHEDULE
TYP SLAB REINF
SHEAR REINF
INTERSECTING BEAM
BC OR B REINF, PLACE BC
REINF @ STIRRUP CORNERS,
BC REINF SHOULD BE PLACED
IN LOWER LAYER UNO
DIA OF LARGEST
T OR TC BAR,
1 1/2" CLR MIN
DIA OF LARGEST B OR BC BAR, 1
1/2" CLR MIN
NTS
SLAB SLAB
L1 L2
SHEAR REINF
FOR SIZE AND SPACING, SEE SCHEDULE
SHEAR REINF
FOR SIZE AND SPACING, SEE SCHEDULE
TYPTYP
BE
AM
D
EP
TH
3"
2"
3"
4"
D
1/4 L1 1/3 L1 OR 1/3 L2
WHICHEVER
IS GREATER
WHICHEVER
IS GREATER
1/3 L1 OR 1/3 L2
BEAM WIDTH
W
CLR
CLR
FOR STIRRUPS AND CLOSURE BARS
2" 2"
10#8
STANDARD 90
DEG ACI BEND
TYPICAL BEAM
SEE SCHEDULE
4" =2
'-0
6S
PA
JO
IN
T H
O O
PS
C O
L H
O O
PS
VERTICAL REINF
SEE SCHEDULE
TYP
C O
L
TI
ES
SE
E
SC
H
ED
U
LE
JO
IN
T H
O O
PS
C O
L H
O O
PS
6S
PA
4" =2
'-0
C O
L H
O O
PS
TIE SPACING
SEE SCHEDULE
LAP COMPRESSION SPLICE
SEE TABLE. SPACE TIES
@ 1/2 TIE SPACING
VERTICAL DOWELS
SAME SIZE AS COLUMN
VERTICAL REINF
C O
L H
O O
PS
C
O L
TI
ES
SE
E
SC
H
ED
U
LE
C
LE
AR
H
EI
G
H T
O F
C O
LU
M
N
SE
C
O N
D F
LO
O
R T
O R
O O
F C
LE
AR
H
EI
G H
T O
F C
O
LU
M N
G
R O
U N
D F
LO
O
R T
O S
EC
O
N D
F
LO
O R
TYPICAL BEAM
SEE SCHEDULE
MECHANICAL CONNECTORS MAY BE
USED BE USED IN LIEU OF LAP COMPRESSION
SPLICES. STAGGER SPLICES WITH A MIN
OF 12" SPACING BETWEEN CONNECTORS
STAGGER SPLICES FOR
COLUMNS W/MORE THAN
4 VERTICAL BARS
EL. SEE DWGS
EL. SEE DWGS
EL. SEE DWGS
JOINT HOOPS SPACED
AT 6" O.C. FOR DEPTH
OF SHALLOWEST BEAM
#3 #4 #5 #6 #7 #8 #9 #10 #11
"W" OR "D"
20"
CL
TYPICAL COLUMN REINFORCING
NTS
COMPRESSION LAP
SPLICES WITH TIES
TYPICAL COLUMN SECTION
NTS
21" 24" 27" 30" 33" 36" 40" 43"
W = 12"
D
0"
#4@12
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-S-3D-101.rvt 6/10/2020 4:55:11 PM
NONE
BEAM AND COLUMN
SCHEDULE
GENERAL
70.24-2- 9
G-009NOV 2019
CONCRETE BEAM SCHEDULE
MARK
DIMENSION
TOP
REINFORCING
BOTTOM
REINFORCING TOTAL S
BARS
SHEAR REINFORCING
REMARKS
"W" "H" TC BC NO. SIZE SPACING FROM LEFT SUPPORT
B1 1' - 8" 2' - 0" 4#9 4#9 4#9 2#4 @9" TYPE 1
B2 1' - 4" 2' - 0" 3#9 3#9 4#9 2#4 @9" TYPE 1
B3 2' - 0" 2' - 0" 4#9 4#9 4#9 2#4 @9" TYPE 1
B4 2' - 6" 2' - 0" 5#9 5#9 4#9 2#4 @9" TYPE 1
B5 1' - 0" 2' - 0" 3#9 4#9 4#9 2#4 @9" TYPE 1
B6 2' - 0" 1' - 6" 4#9 4#9 4#9 2#4 @9" TYPE 1
1 06/2020 AMENDMENT 0002 GP
B
14" DIA
12' - 0"
6' - 3" 4' - 9"
6'
0" 5'
8"
M26 -
EXISTING
FILTER
BUILDING
TOC 170.50
6' - 6"
9'
4"
TOP EL 171.00
TOC 170.50
3 5
3 5
BOX ACCESS HATCH
FILTER BUILDING
MIXING CHAMBER
A
6" 1'
0"
1'
0"
2'
6"
1'
0"
2'
6"
1'
0"
6"
6" 1' - 0" 10' - 0" 1' - 0" 6"
B
HP EL 160.00
H
P EL 160.00
EL 160.00
EL 160.00
SL
O
PE
SLOPE
EL 158.75
LP EL
159.75
TYP
TYP
M26 - EXISTING
FILTER BUILDING
TOE OF
EXST
FOOTING
DIVERSION
BOX
6'
9" 12' - 6"
FINAL MIXING CHAMBER
1'
6" 9'
3"
1'
3"
EL 170.50
EL 166.25
WEIR
WALL
EL 160.00
#7 @ 12
EW, T&B
#7@12
EW, EF, TYP
#7 @ 12
EW, T&B
EL 158.50
#7@12
EW, EF, TYP
#6@12
EW, EF
#7@12
EW, EF
1' - 0"
2' - 6"
1' - 0"
ALUMINUM SIDEWALK
DOOR SHOWN IN
OPEN POSITION 5
9 TYP
M26 -
EXISTING
FILTER
BUILDING
EL 157.50
#7@12 W/STD HOOK
#7@12
W/STD
HOOK, TYP
#6@12 EW
6' - 9" 10
#7@12
EL 162.00
EL 170.50
EL 160.00
M26 -
EXISTING
FILTER
BUILDING
#7 @ 12
EW, T&B
#7@12
EW, EF, TYP
DIVERSION BOX
2'
0"
5' - 6"
FILTER BUILDING
FOOTING PROJECTION
12' - 6" 10 11
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-S-3D-101.rvt 6/10/2020 4:55:22 PM
1/4"=1'-0"
FILTER AND CHEMICAL BUILDING
DIVERSION BOX
PLANS AND SECTIONS
STRUCTURAL
70.24-2- 25
S-101M26NOV 2019
1/4" = 1'-0"
UPPER PLAN
1/4" = 1'-0"
LOWER PLAN
3/8" = 1'-0"25
A SECTION
3/8" = 1'-0"25
B SECTION
N N 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
0 2' 4' 8'
SCALE: 3/8" = 1'-0"
0 2' 4' 8'
SCALE: 3/8" = 1'-0"
FOR GENERAL STRUCTURAL NOTES, SEE PLATE 01-G-005.1.
GENERAL SHEET NOTES
CONTRACTOR SHALL COORDINATE WITH OTHER DISCIPLINES
FOR THE LOCATION OF ALL EMBEDDED ITEMS SUCH AS WALL
PIPES, WALL SLEEVES, ETCETERA.
SHEET KEY NOTES
FOR WALL CORNER AND INTERSECTION REINFORCEMENT SEE
DETAIL 118 / PLATE 72.
1.
ALUMINUM PIPE LADDER UNDER COVER PER DETAIL
137 / PLATE 74.
2.
PROVIDE ADDITIONAL REINFORCING AT OPENING PER
DETAIL 116 / PLATE 72.
3.
ALUMINUM DOUBLE LEAF SIDEWALK DOOR FOR 5'-0"X5'-0" OPENING4.
ALUMINUM SIDEWALK DOOR FOR 2'-6"X3'-0" OPENING.5.
3'-9"X 1'-10" OPENING IN SLAB.6.
FOR CONSTRUCTION JOINT LOCATION IN WALLS SEE
DETAIL 108 / PLATE 71.
3.
SEE SECTIONS FOR REINFORCEMENT.4.
COORDINATE WITH PROCESS AND MECHANICAL FOR PIPE
PENETRATION AND EMBEDMENT. PROVIDE ADDITIONAL
REINFORCING AT OPENINGS OR PENETRATIONS LARGER THAN
10 INCHES PER DETAIL 116 / PLATE 72.
5.
1'-0" WIDE X 6" HIGH CONCRETE CURB PER DETAIL 127 / PLATE 72.7.
ALUMINUM CHECKERED PLATE COVER, 3/8" THICK. SECURE TO
CONCRETE CURB WITH (6) 5/8" DIAMETER ADHESIVE ANCHORS
WITH 3" EMBEDMENT.
8.
WALL BASE CONSTRUCTION JOINT PER DETAIL 114 / PLATE 71.
PROVIDE ADDITIONAL REINFORCING PER DETAIL 119 / PLATE 72.
9.
M29
M26
KEY PLAN
DIMENSION IS FROM OUTSIDE FACE OF CONCRETE BELOW BRICK.10.
INSTALL EAST WALL OF DIVERSION BOX PARALLEL WITH WEST
WALL OF EXISTING FILTER BUILDING.
11.
ALL WORK ASSOCIATED
WITH THE DIVERSION BOX
SHALL BE BID AS OPTION 1
1 06/2020 AMENDMENT 0002 GP
PROVIDE CIRCULAR REINFORCING AT PIPE PENETRATION PER
DETAIL 116/PLATE 72.
12.
2.
DN
A
B
FINAL MIXING
CHAMBER NO. 1
FINAL MIXING
CHAMBER NO. 2
UPFLOW CHAMBER
BEAM ABOVE
SETTLED WATER
FLOW METER
CHAMBER (BELOW)
84" CONC
SETTLED WATER
MAIN, CL 158
24" EQUALIZED
BACKWASH
DRAIN, IE 164.75
48" CONC SPENT
WASHWATER
DRAIN, IE 157.50
6" DRAIN
CL 152.08
SUMP
WEST SPENT
WASHWATER
CHANNEL
NEW ISOLATION/
OVERFLOW
WEIR GATE
FV
M29-1
HALLWAY
MATCHLINE
SEE PLATE 29
EXST RETAINING
WALL TO REMAIN
EL 162.0
EL 151.0
1' - 5"
1'
5"
A
B
NEW ISOLATION/
OVERFLOW
WEIR GATE
FV
M29-1
EXST MIXER
TO BE
REMOVED
UPFLOW CHAMBER
SETTLED WATER
CHANNEL
NEW CONC BEAM
SUPPORTED BY
WALLS BELOW
177.67
168.50
170.67
SETTLED WATER
FLOW METER
CHAMBER (BELOW)
NEW OPENING
EXST STAIR
TO REMAIN
48" CONC SPENT
WASHWATER
DRAIN, IE 157.50
6" DRAIN
CL 152.08
24" EQUALIZED
BACKWASH
DRAIN, IE 164.75
TOP OF EXST
CONC FILL 152.00
EL 168.50
WEST
SETTLED
WATER
CHANNEL
WEST SPENT
WASHWATER
CHANNEL
EL 162.00
EL 177.67
FINAL
MIXING
CHAMBER
NO. 1
FINAL
MIXING
CHAMBER
NO. 2
CSEE ENLARGED
SECTION
EXST MIXER TO
BE REMOVED, TYP
4 4
NEW CONC
BEAM
FV
M29-1
1' - 5"
TOP OF EXST CONC FILL 152.00
EL 168.50
EL 177.67
EL 162.00
FV
M29-1
NEW ISOLATION/
OVERFLOW
WEIR GATE
GATE STEM
TYP 2
NEW CONC
BEAM
1" GROUT
1" GROUT
HALLWAY
12" MIN
2' - 6"
(2) #6 ADHESIVE
DOWELS W/5"
EMBEDMENT
1' - 6"
1" GROUT
EL 162.00
NEW ISOLATION/
OVERFLOW
WEIR GATE
FV
M29-1
EL 168.50
REMOVE
SECTION OF
SLAB TO INSTALL
NEW WEIR GATE
NEW CONC BEAM
SHALL BE INSTALLED
PRIOR TO DEMOLITION
OF ADJACENT SLAB
WEST SPENT
WASHWATER
CHANNEL
WEST
SETTLED
WATER
CHANNEL
NEW 8"x5" SST
INVERTED OFFSET
CHANNEL WITH
GASKETS PROVIDED BY
GATE MANUFACTURER
1'
0"
(5) #6
#6@12 ADHESIVE
DOWELS W/5"
EMBEDMENT
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-D-3D-101.rvt 6/10/2020 5:32:52 PM
AS
NOTED
FILTER AND CHEMICAL BUILDING
FINAL MIXING CHAMBER
PLANS AND SECTIONS
PROCESS
70.24-2- 28
D-103M26NOV 2019
1/4" = 1'-0"
MIXING CHAMBER PLAN AT ELEV 168.5
1/4" = 1'-0"28
A SECTION
1/4" = 1'-0"28
B SECTION
1/2" = 1'-0"28
C ENLARGED SECTION
SHEET KEY NOTES
1. PROVIDE MECHANICAL JOINT FITTING WITHIN 2'-0" OF OUTSIDE
WALL FOR FLEXIBILITY. CORE DRILL HOLES IN EXISTING
CONCRETE WALL AND INSTALL NEW 30" AND 24" PIPES PER
DETAIL 311/PLATE 78.
2. APPROXIMATE LOCATION OF SEVERAL 1"-2" PVC PIPES AND
CONDUITS SERVING PILOT TRAILER LOCATED WEST OF
EXISTING RETAINING WALL. CONTRACTOR SHALL PROVIDE
TEMPORARY SUPPORTS FOR PILOT PLANT UTILITIES AS NEW
24" EQUALIZED BACKWASH DRAIN IS INSTALLED. BACKFILL
TRENCH WITH FLOWABLE FILL FOLLOWING INSTALLATION.
3. CONTRACTOR SHALL DEMOLISH EXISTING WOOD PLATFORM
AND STAIR.
4. SEAL FLOOR OPENING FOLLOWING REMOVAL OF MIXER WITH
NON SHRINK GROUT. ENLARGE TOP OF HOLE TO CREATE A
FUNNEL SHAPED HOLE TO PREVENT NEW GROUT PLUG FROM
DROPPING THROUGH HOLE. BURN ALL ANCHOR BOLTS TO
MINIMUM 1" BELOW TOP OF SLAB AND FILL HOLES WITH NON
SHRINK GROUT.
5. CONTRACTOR SHALL DEMOLISH EXISTING WORK BENCH AND
ELECTRICAL RECEPTACLES. REMOVE CONDUIT AND WIRING
FEEDING THE RECEPTACLES TO THE FIRST JUNCTION BOX ON
THE INCOMING CONDUIT.
N 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
N 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
6. REMOVE ELECTRICAL RECEPTACLES ON SIDE OF WOOD
PLATFORM. REMOVE CONDUIT AND WIRING TO THE
RECEPTACLE FEEDING THE RECEPTACLES ON THE EAST
WALL.
M29
M26
KEY PLAN
K3
16a
K1 J3 J2
K3 K1 J3 J2
16a
1 06/2020 AMENDMENT 0002 GP
B
FILTER INFLUENT
CHANNEL
(BOTTOM EL 168.50)
30" FLANGED
ISOLATION
BUTTERFLY
VALVE WITH
VERTICAL
STEM, IE 169.50
HOLE FOR EXTENSION
BONNET, CAULK OPENING
TO MAKE WATERTIGHT
FLOW METER REMOVAL
HATCH
30" SETTLED
WATER
DIVERSION PIPE
VAULT ACCESS HATCH
VALVE REMOVAL
CHECKER PLATE
WEIR CHAMBER ACCESS
HATCH
LIMITS OF INSULATION
A
B
30" SETTTLED
WATER DIVERSION
PIPE, IE 162.00
30" MAG METER
30" RESTRAINED
FCA
30" FLOW CONTROL VALVE WITH
EXTENSION BONNET AND ACTUATOR
INSTALLED 3'-0" ABOVE TOP OF
VAULT. SEAL OPENING BETWEEN
EXTENSION BONNET AND HOLE IN
CHECKER PLATE WITH CAULKING
30" BURIED MJ ISOLATION
BUTTERFLY VALVE WITH
HORIZONTAL STEM AND
BURIED RIGHT ANGLE WORM
GEAR DRIVE AND VALVE BOX
WITH EXTENSION STEM
TOP OF WEIR
EL 166.50
FINAL MIXING
CHAMBER NO. 2
MATCHLINE
SEE PLATE 28
FINAL MIXING
CHAMBER NO. 1
TOE OF
EXST
FOOTING
FILTER
BUILDING
FE
M26-1
FCV
M26-2
78SEE
FILTER
INFLUENT
CHANNEL
EL 168.50
EL 162.00
EL 160.00
EL 170.50
30" DIVERSION
PIPE, IE 162.00
LIMITS OF
INSULATION
FILTER
OPERATING
LEVEL
TYPICAL WATER
LEVEL 174.2
BOTTOM OF BRICK
EL 170.45
SPENT
WASHWATER
CHANNEL
C
INSTALL SST
L3X3X1/4 W/ 1/2"
DIAMETER ADHESIVE
ANCHOR @ 16" TO
ALLOW REMOVAL OF
BRICKS BELOW
RESTORE BRICK
AROUND PIPE
FILL VOID W/
NONSHRINK
GROUT TO
FACE OF BRICK
30" FLANGED
ISOLATION
BUTTERFLY
VALVE WITH
VERTICAL
STEM, IE 169.50
SEE
1' - 5"
1' - 6"
STRAIGHT LENGTH
12' - 6"
TOP OF WEIR
EL 166.50, SEE
FINAL MIXING CHAMBER NO. 2
6" CURB
EL 160.00
EL 170.50
EL 168.50
STRAIGHT LENGTH
7' - 6"
FE
M26-1
ELEC
ACTUATOR
EXST GRADE
APPROX 170.0
GROUT FILL30" MAG METER,
SEE
30" SETTTLED
WATER DIVERSION
PIPE, IE 162.00
SEE
TYP 3 PLACES
BURIED MJ
BUTTERFLY
VALVE, SEE
HWL = 164.00 (FROM
RECORD DRAWINGS)
OPENING
UNDER
DIVIDER WALL
FCV
M26-2
1' - 5"
BOTTOM OF BRICK
EL 170.45
INSTALL SST
L3X3X1/4 W/ 1/2"
DIAMETER ADHESIVE
ANCHOR @ 16" TO
ALLOW REMOVAL OF
BRICKS BELOW
FILL VOID W/
NONSHRINK
GROUT TO
FACE OF BRICK
NEW BRICK
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-D-3D-101.rvt 6/10/2020 5:33:02 PM
AS
NOTED
FILTER AND CHEMICAL BUILDING
DIVERSION BOX
PLANS AND SECTIONS
PROCESS
70.24-2- 29
D-104M26NOV 2019
1/4" = 1'-0"
DIVERSION BOX UPPER PLAN 1/4" = 1'-0"
DIVERSION BOX LOWER PLAN
1/4" = 1'-0"29
A SECTION
1/4" = 1'-0"29
B SECTION
N 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
SHEET KEY NOTES
1. CORE DRILL HOLE IN EXISTING CONCRETE WALL AND INSTALL
NEW 30" SETTLED WATER DIVERSION PIPE AND MODULAR
MECHANICAL SEAL PER DETAIL 311/PLATE 78.
3/8" = 1'-0"29
C SECTION
J2J3
K1K3
16a
J3
K1K3
16a
ALL WORK ASSOCIATED
WITH THE DIVERSION BOX
SHALL BE BID AS OPTION 1
N 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
M29
M26
KEY PLAN
1 06/2020 AMENDMENT 0002 GP
C
D
B
F
E
1'
6"
2'
0"
1' - 6" 67' - 8" 1' - 6"
M29 - BACKWASH EQUALIZATION BASINS
M30 - BACKWASH
EQUALIZATION
PUMPING STATION
M26 - EXISTING FILTER BUILDING
EXISTING ACCESS RAMP
BACKWASH
EQUALIZATION
BASIN CELL 2
BACKWASH
EQUALIZATION
BASIN CELL 1
BYPASS
CHANNEL
BACKWASH WASTE
CONNECTION CONDUIT
1'
6"
1'
0"
5'
0" 2'
0"
H
J
I
2'
3"
1' - 0" 4' - 0" 2' - 0" 102' - 6" 2' - 0" 4' - 0" 1' - 0"
9' - 9 1/2"
K
EL 165.50
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-S-3D-101.rvt 6/10/2020 4:55:34 PM
1/8"=1'-0"
OVERALL PLAN
STRUCTURAL
70.24-2- 37
S-100M29-M30NOV 2019
1/8" = 1'-0"
OVERALL PLAN
KEY PLAN
M26
M29
M30
8'4' 16'0
SCALE: 1/8"=1'-0"
N
1 1
UP
UP
C
D
1'
6"
1'
6"
BACKWASH
EQUALIZATION
BASIN CELL 1
BACKWASH
EQUALIZATION
BASIN CELL 2
SUMP
FLOW METER AND
CONTROL VALVE
ROOM
B101
WEIR
WALL
DRAIN TRENCHDRAIN TRENCH
1'
6"
20' - 5" 1' - 0" 3' - 6"
2' - 0" 16' - 0" 1' - 0" 16' - 0" 1' - 0" 16' - 0" 2' - 6" 16' - 0" 1' - 0" 16' - 0" 1' - 0" 16' - 0" 2' - 0"
M30 - BACKWASH
EQUALIZATION
PUMPING STATION
M29 - BACKWASH
EQUALIZATION BASIN
3" D X 4" W TRENCH,
FOR REINFORCING SEE
C1C1LP EL 149.50
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
C1C1LP EL 149.50 LP EL 149.50 LP EL 149.50 LP EL 149.50 LP EL 149.50
1' - 9"
8'
0"
LP EL 143.00
LP EL 143.00
HP EL 143.21
SL
O
PE
SL
O
PE
SLOPE
LP
E
L
3.
LP
E
L
3.
143.00
SLOPE
146.75
SLOPE
LANDING AT EL 143.00 AND 157.00
2 150.00
1 TYP
143.00143.00
1'-0" HIGH
CONC
CURB, TYP
4 1 1
CONC FILL,
SEE SECTION
10' - 0"10' - 0"
EL 142.75 AT
BOTTOM OF TRENCH
CONC
FILL, SEE
SECTION
'-1
TOP OF GRATING
EL SHALL MATCH
ADJACENT FLOOR
H
J
I
G
17' - 11" 1' - 6" 8' - 4" 1' - 0" 62' - 9" 3' - 0" 1' - 6" 9' - 0" 1' - 6"
STAIR
1S1
A
C
F
E
BACKWASH
EQUALIZATION
BASIN CELL 2
BACKWASH
EQUALIZATION
BASIN CELL 1
TYP
3' - 7 1/2"
TYP
8' - 2 1/2"
TYP
4' - 2"
2' - 0" 16' - 0" 1' - 0" 16' - 0" 1' - 0" 16' - 0" 2' - 6" 16' - 0" 1' - 0" 16' - 0" 1' - 0" 16' - 0" 2' - 0"
M29 - BACKWASH EQUALIZATION BASIN
HP EL 150.80
CONC FILL,
SEE SECTION
HP EL 150.80 HP EL 150.80 HP EL 150.80 HP EL 150.80 HP EL 150.80
1 TYP
2'-0" HIGH
CONC
CURB, TYP
1'-0" HIGH
CONC
CURB, TYP
1 TYP
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
1'
0"
'-1
FILENAME: PLOT DATE/TIME:
DRAWING NUMBER PLATE
SHEETDATESCALE
REV DATE DESCRIPTION BY
U.S. ARMY ENGINEER DISTRICT,
BALTIMORE
CORPS OF ENGINEERS
BALTIMORE, MARYLANDUS Army Corps of Engineers ®
WASHINGTON AQUEDUCT
MCMILLAN BACKWASH DISCHARGE
TO SEWER
BUILDING ID
R:\d0224752\M29-S-3D-101.rvt 6/10/2020 4:55:44 PM
1/4"=1'-0"
LOWER LEVEL PLANS
STRUCTURAL
70.24-2- 38
S-101M29-M30NOV 2019
1/4" = 1'-0"
LOWER PLAN - SOUTH
1/4" = 1'-0"
LOWER PLAN - NORTH 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
N
N
KEY PLAN
M30
M29
M26
FOR GENERAL STRUCTURAL NOTES, SEE PLATE 6.1.
GENERAL SHEET NOTES
CONTRACTOR SHALL COORDINATE WITH OTHER DISCIPLINES
FOR THE LOCATION OF ALL EMBEDDED ITEMS SUCH AS WALL
PIPES, WALL SLEEVES, ETCETERA.
2.
SHEET KEY NOTES
COORDINATE FINAL DIMENSIONS OF OPENING WITH FLUSH
GATE MANUFACTURER.
11.
FOR WALL CORNER AND INTERSECTION REINFORCEMENT SEE
DETAIL 118 / PLATE 72.
1.
CONCRETE TOPPED METAL PAN STAIR LANDING, SEE DETAIL
136 / PLATE 73.
2.
CONCRETE TOPPED METAL PAN STAIRS, SEE DETAIL 135 / PLATE 73.3.
STAINLESS STEEL PIPE LADDER UNDER COVER, SEE DETAIL
137 / PLATE 74.
4.
STAINLESS STEEL PIPE LADDER WITH EXTENSION, SEE
DETAIL 137 / PLATE 74.
5.
GATE OPENING, SEE SECTIONS. PROVIDE ADDITIONAL
REINFORCING AT OPENING PER DETAIL 116 / PLATE 72.
6.
COVER TRENCH WITH 1" THICK ALUMINUM GRATING AT
DOOR. MINIMUM WIDTH SHALL EXTEND 9" BEYOND DOOR
OPENING. SEE DETAILS 145 TO 148 / PLATE 74.
7.
ALUMINUM GRATING PER DETAILS 145 TO 148 / PLATE 74.8.
ALUMINUM RAILING, SEE DETAILS 140 AND 143 / PLATE 74.9.
WALL HANDRAIL, SEE DETAIL 144 / PLATE 74.10.
FOR CONSTRUCTION JOINT LOCATION IN WALLS SEE DETAIL 108 /
PLATE 71.
3.
SEE SECTIONS FOR REINFORCEMENT.4.
COORDINATE WITH PROCESS AND MECHANICAL FOR PIPE
PENETRATION AND EMBEDMENT. PROVIDE ADDITIONAL
REINFORCING AT OPENINGS OR PENETRATIONS LARGER THAN
10 INCHES PER DETAIL 116 / PLATE 72.
5.
1 06/2020 AMENDMENT 0002 GP
C
F
E
8'
0"
7' - 9" 4' - 6" 7' - 9"
WASTE BACKWASH
CONNECTION CONDUIT
SEE PLATE 40
C O
N C
R
ET
E W
AL
KW
AY
ALUMINUM GRATING
BACKWASH EQUALIZATION BASIN CELL 2BACKWASH EQUALIZATION BASIN CELL 1
4' - 0" 12' - 0" 4' - 0"
M29 - BACKWASH EQUALIZATION BASIN
1 TYP
'-1
4'
0"
171.00
AND
GS-1 SUPPORT
TYP
1 TYP
1 TYP
1 TYP
1'
6" 2'
0"
4'
6"
C
D
BACKWASH EQUALIZATION BASIN CELL 1 BACKWASH EQUALIZATION BASIN CELL 2
1'
6"
TY
P
1'
0"
8' - 4"
OPNG
4' - 0" 9' - 0"
OPNG
6' - 4" 9' - 0"
OPNG
4' - 0" 8' - 4"
6" 22' - 5" 11' - 4" 49' - 6" 8' - 4" 1' - 6"
17' - 11" 4' - 6" 6"
88' - 7"
M30 - BACKWASH
EQUALIZATION
PUMPING…