Amendment_0001_Exhibits_B _C_ _D_Base_Year.xlsx
XLSX spreadsheet 127 KB Posted
- Attached to
- Maintenance & Repair Gray Cyber Center
- Solicitation number
- W912CM-16-T-0032
About this file
W912CM-16-T-0032 Amendment 0001 Exhibits B C D for Base Year
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_-_W912CM-16-T-0032-0001.pdf | ||
| QA_W912CM-16-T-0032.pdf | ||
| b._Exhibit_A_Inventory_List_Base_Year.xlsx | XLSX spreadsheet | |
| f._409th_NCR_Form.pdf | ||
| h._Attachment_2_-_Past_Performance_Questionnaire.docx | DOCX document | |
| a._W912CM-16-T-0032.pdf | ||
| c._Exhibits_B_C_D_Base_Year.xlsx | XLSX spreadsheet | |
| g._Attachment_1_-_REFERENCE_INFORMATION_SHEET.docx | DOCX document | |
| e._Exhibit_E_BImSchGenehmigung.pdf | ||
| d__Exhibits_B_C_D_1st_Option_Year.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Exhibit_B1_HVAC BY
VDMA 24186
Maintenance instructions Chapter / Wartungsanleitung Kapitel VDMA 24186 Maintenance instructions Classification and item description / Wartungsanleitung Klassifizierung und Positions-
| Beschreibung | Additional Maintenance Requirements e.g. manufacturer's instructions/ Zusätzliche Anforderungen an die Wartung wie z.B. Herstellerangaben |
| # | CLIN/Trade / |
CLIN/Gewerk
| Unit ID | Inventory Num | Installation / | ||
| Errichter | System | |||
| Name | Location / | |||
| Einbauort | Room / | |||
| Raum | Type of Unit / Gerät | Manufacturer / Hersteller | Type/Model | Constr. |
| Year | WRG | |||
| [kW] | Cooling | |||
| [kW] | Heating | |||
| [kW] | KM-Menge | |||
| [kg] | Air Volume | |||
| [m³/h] | Electr. | |||
| [kW] | Filters | Each / | ||
| Stck | PM | |||
| p.a. | Cost Each / Kosten pro Stück [€] | Kosten Basis Jahr / Base Year |
Cost PM p.a. [€]
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 1.4 Combined heat and power plant (CHP) / 1.4 Blockheizkraftwerke (BHKW) | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 1 | 0001/HVAC | CHP | CHP1 + 2 | apikal | Heating/ Power | Basement | U.20 | CHP Unit/ BHKW; VITOBLOC 200 | Viessmann ESS | EM-238/363 | 2013 | 0 | 0 | 363 | 0 | 0 | 238 | 0 | 2 | 1000 OPHR | - 0 € | - 0 € | |||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 7 Absorbers / 7 Absorber | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 3 | 0001/HVAC | ARM | ARM | apikal | Cooling | Basement | U.15 | Adsorption Refrigerator; Thermax LT C | |||||||||||||||||
| Absorptionskältemaschine | Trane | LT 14 C | 2013 | 0 | 634.08 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | Reciprocating and rotary compressors / Hubkolben- und Rotationsverdichter | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 4 | 0001/HVAC | CM | CM1 + 2 | apikal | Cooling | Basement | U.13 | Chiller; RTWD-1 | |||||||||||||||||
| Kältemaschine | Trane | RTWD 160 PE | 2013 | 0 | 499.62 | 634.08 | 2*80 | 0 | 134.5 | 0 | 2 | 1 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 4.2 Dry recooling systems / 4.2 Trockenrückkühlanlagen | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 6 | 0001/HVAC | HE | HE1 + 2 | apikal | Heat Exchanger CM2 | Roof North | Roof North | Heat Exchanger CM 2 | |||||||||||||||||
| Trockenrückkühler | Cabero | GCDD087KB-2x4-72-L D | 2013 | 0 | 815 | 0 | 0 | 169,040 | 8*12 | 0 | 2 | 1 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 4.1 Evaporative recooling systems (cooling towers) / 4.1 Verdunstungsrückkühlanlagen (Kühltürme) | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 8 | 0001/HVAC | CT | CT | apikal | Cooling Tower ARM/CHP | Roof North | Roof North | open cooling Tower DT3/57 Z | |||||||||||||||||
| offener Kühlturm | Gohl | 4/013503/13 | 2013 | 0 | 1,590 | 0 | 0 | 90,000 | 11 | 0 | 1 | 4 | - 0 € | - 0 € | ||||||||||||
| 6. SANITARY INSTALLATIONS / 6. SANITÄRTECHNISCHE ANLAGEN | 1.7 Neutralizing plants / 1.7 Neutralisationsanlagen | not applicable | 9 | 0001/HVAC | NA | NA | apikal | Neutralisationsanlage | CGP Room | 0 | Neutralisationsanlage | Grünbeck | GENO-Neutra | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 5.1 Fans / 5.1 Ventilatoren | not applicable | 10 | 0001/HVAC | AC | FC1-55 | apikal | Climate | Office | 1.01 | Fan Coil/ Umluftgerät | |||||||||||||||
| Installation Hight / Einbauhöhe >3m | GEA | GM31.UWW3.K00G2 | 2013 | 0 | 2,3-3,5 | 3,9-5,0 | 0 | 755-1210 | 0,144-0,199 | G3 | 55 | 4 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 5.1 Fans / 5.1 Ventilatoren | not applicable | 65 | 0001/HVAC | AC | FC56-59 | apikal | Climate | JOC Room | 2.05 | Fan Coil/ Umluftgerät | |||||||||||||||
| Installation Hight / Einbauhöhe >5m | GEA | GM41.UWW4.K00G2 | 2013 | 0 | 2,3-3,5 | 3,9-5,0 | 0 | 755-1210 | 0,144-0,199 | G3 | 4 | 4 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 5.1 Fans / 5.1 Ventilatoren | not applicable | 69 | 0001/HVAC | AC | FC60 - 67 | apikal | Cooling | Communication | U.12 | Fan Coil/ Umluftgerät | |||||||||||||||
| Installation Hight / Einbauhöhe >3m | Thermo-Tec | ZEFRIO 1260HB | 2013 | 0 | 5.85 | 0 | 0 | 1050 | 3 | 0 | 8 | 4 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 5.1 Fans / 5.1 Ventilatoren | not applicable | 77 | 0001/HVAC | AC | AC68 | apikal | Cooling | Fire Alarm Center | 1.21 | Fan Coil/ Umluftgerät | |||||||||||||||
| Installation Hight / Einbauhöhe >3m | Thermo-Tec | HWN1-40 | 2013 | 0 | 5.85 | 0 | 0 | 450 | 0.2 | 0 | 1 | 4 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 2.1 Water-cooled condensers / 2.1 Wassergekühlte Verflüssiger | maintenance according to the manufacturer's instructions | 79 | 0001/HVAC | CC | CC1 | apikal | Cooling | Server Farm | 1.04 | Precision air-conditioning system/ Klimaschrank | Thermo-Tec | Next Evo CW U 6R 098 E6 / M-13-03160 | 2013 | 0 | 0 | 0 | 0 | 0 | 4 | G4 | 2 | 4 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 2.1 Water-cooled condensers / 2.1 Wassergekühlte Verflüssiger | maintenance according to the manufacturer's instructions | 81 | 0001/HVAC | CC | CC3 | apikal | Cooling | USV | U.19 | Precision air-conditioning system/ Klimaschrank | Thermo-Tec | neXt CW.U 012.H1 / M-13-03155 | 2013 | 0 | 12.7 | 0 | 0 | 2653 | 4 | G4 | 2 | 4 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 2.3 Air-cooled condensers / 2.3 Luftgekühlte Verflüssiger | maintenance according to the manufacturer's instructions | 83 | 0001/HVAC | LCP | LCP1-1 to 7-8 | Rittal | Cooling | Server Farm | 1.04 | Liquid Cooling Package | Rittal | 3311.130 | 2013 | 0 | 30 | 0 | 0 | 4800 | 1.1 | 0 | 60 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 2.3 Air-cooled condensers / 2.3 Luftgekühlte Verflüssiger | not applicable | 143 | 0001/HVAC | LCP | LCP1-1 to 11-6 SCIF | Rittal | Cooling | SCIF | 1.18 | Liquid Cooling Package | Rittal | 3311.130 | 2013 | 0 | 30 | 0 | 0 | 4800 | 1.05 | 0 | 6 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 2.3 Air-cooled condensers / 2.3 Luftgekühlte Verflüssiger | not applicable | 149 | 0001/HVAC | LCP | LCP | Rittal | Cooling | USV | U.19 | Liquid Cooling Package | Rittal | 3311.130 | 2013 | 0 | 30 | 0 | 0 | 4800 | 2.2 | 0 | 4 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 2.3 Air-cooled condensers / 2.3 Luftgekühlte Verflüssiger | not applicable | 150 | 0001/HVAC | LCP | LCP71 | Rittal | Cooling | TR | 1.12 | Liquid Cooling Package | Rittal | 3311.530 | 2013 | 0 | 30 | 0 | 0 | 4800 | 1.05 | 0 | 4 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 154 | 0001/HVAC | P | P1 | apikal | HE1 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 100-200/554 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 5.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 155 | 0001/HVAC | P | P2 | apikal | HE2 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 100-200/554 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 5.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 156 | 0001/HVAC | P | P03.1 | apikal | CT | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 125-200/754 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 7.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 157 | 0001/HVAC | P | P03.2 | apikal | CT | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 125-200/754 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 7.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 158 | 0001/HVAC | P | P04.1 | apikal | CM1 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 080-210/304 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 159 | 0001/HVAC | P | P04.2 | apikal | CM2 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 080-210/304 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 160 | 0001/HVAC | P | P04.3 | apikal | ARM | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 080-210/304 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 161 | 0001/HVAC | P | P04.4 | apikal | Reserve | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 080-210/304 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 162 | 0001/HVAC | P | P05.1 | apikal | Climate | Cooling Ceiling | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 065-160/154 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 1.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 163 | 0001/HVAC | P | P05.2 | apikal | Climate | Cooling Ceiling | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 065-160/154 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 1.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 164 | 0001/HVAC | P | P06.1 | apikal | Climate | Fan Coil | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 050-160/074 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.75 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 165 | 0001/HVAC | P | P06.2 | apikal | Climate | Fan Coil | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 050-160/074 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.75 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 166 | 0001/HVAC | P | P07.1 | apikal | Cooling | LCP COM SCIF | 1.18 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 032-200/074 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.75 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 167 | 0001/HVAC | P | P07.2 | apikal | Cooling | LCP COM SCIF | 1.18 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 032-200/074 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.75 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 168 | 0001/HVAC | P | P08.1 | apikal | AHU1&2 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 065-054/074 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.75 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 169 | 0001/HVAC | P | P09.1 | apikal | Climate | Server Farm | 1.04 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 065-154/074 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.75 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 170 | 0001/HVAC | P | P09.2 | apikal | Climate | Server Farm | 1.04 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 065-154/074 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.75 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 171 | 0001/HVAC | P | P10.1 | apikal | Primär | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 125-160/304 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 172 | 0001/HVAC | P | P10.2 | apikal | Primär | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 125-160/304 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 173 | 0001/HVAC | P | P11.1 | apikal | AHU2 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 050-160/114 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 11 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 174 | 0001/HVAC | P | P11.2 | apikal | AHU1 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 050-160/114 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 11 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 175 | 0001/HVAC | P | P1.1 + P1.2 | apikal | CM1+2 | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 040-160/054 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 0.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 176 | 0001/HVAC | P | P02 | apikal | ARM | Basement | 0 | Circulation Pump / Umwälzpumpe Etaline | KSB | GN 065-250/224 G11 PDB | 2013 | 0 | 0 | 0 | 0 | 0 | 2.2 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 177 | 0001/HVAC | P | P03 | apikal | Fan Coil | Basement | 0 | Circulation Pump / Umwälzpumpe Calio | KSB | 25-60 | 2013 | 0 | 0 | 0 | 0 | 0 | 0.05 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 178 | 0001/HVAC | P | P04 | apikal | Climate | Basement | 0 | Circulation Pump / Umwälzpumpe Calio | KSB | 25-60 | 2013 | 0 | 0 | 0 | 0 | 0 | 0.05 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 179 | 0001/HVAC | P | P05 | apikal | Heating | Basement | 0 | Circulation Pump / Umwälzpumpe Calio Heizkörper | KSB | 25-60 | 2013 | 0 | 0 | 0 | 0 | 0 | 0.05 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 180 | 0001/HVAC | P | P06 | apikal | AHU1&2 | Basement | 0 | Circulation Pump / Umwälzpumpe Calio | KSB | 25-60 | 2013 | 0 | 0 | 0 | 0 | 0 | 0.05 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 181 | 0001/HVAC | P | P07 | apikal | AHU2 | Basement | 0 | Circulation Pump / Umwälzpumpe Calio | KSB | 25-60 | 2013 | 0 | 0 | 0 | 0 | 0 | 0.05 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 6.1 Pumps / 6.1 Pumpen | not applicable | 182 | 0001/HVAC | P | P08 | apikal | AHU1 | Basement | 0 | Circulation Pump / Umwälzpumpe Calio | KSB | 25-60 | 2013 | 0 | 0 | 0 | 0 | 0 | 0.05 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 6.2 Isolating, compensating, safety and control valves / 6.2 Absperr-, Abgleich-, Sicherheits- und Regelarmaturen | not applicable | 183 | 0001/HVAC | P | AV1 | apikal | Climate | Pumps | 0 | Valve /Absperrventil BOA Compact | KSB | PN6 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 6.2 Isolating, compensating, safety and control valves / 6.2 Absperr-, Abgleich-, Sicherheits- und Regelarmaturen | not applicable | 184 | 0001/HVAC | P | AV2 | apikal | Climate | Pumps | 0 | Valve / Absperrventil BOAX-S | KSB | PN6 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | |
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 185 | 0001/HVAC | P | EG | apikal | Climate | Basement | U.01 | Vakuum Sprührohrentgasung | Reflex | Servitec 75/90 6824900/022 | 2013 | 0 | 0 | 0 | 0 | 0 | 1.1 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 5 Pressure retaining equipment / 5 Druckhalteeinrichtungen | not applicable | 186 | 0001/HVAC | P | DH1 | apikal | Heating | Basement | U.01 | Booster Station / Variomat Druckhaltestation Heizung | Reflex | 2-2/60 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 1 | - 0 € | - 0 € | |
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 3.2 Valves / 3.2 Armaturen | not applicable | 188 | 0001/HVAC | P | RV1 | apikal | Climate | Cooling Ceiling | 0 | Valve / Strangregulierungsventil MSV-BD Leno | Danfoss | MSV-BD Leno | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5 | 2 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 9.1 Heating appliances (radiators, panel radiators, convectors) / 9.1 Heizkörper (Radiatoren, Plattenheizkörper, Konvektoren) | not applicable | 193 | 0001/HVAC | HK | HK1 | apikal | Heating | Main Staircase | 1.08 | Radiator Radiapaneel | Zehnder | VV280 | 2013 | 0 | 0 | 2,205 | 0 | 0 | 0 | 0 | 8 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 9.1 Heating appliances (radiators, panel radiators, convectors) / 9.1 Heizkörper (Radiatoren, Plattenheizkörper, Konvektoren) | not applicable | 194 | 0001/HVAC | HK | HK2 | apikal | Heating | Staircase North/South | U.16/U.02 | Radiator Charleston | Zehnder | 3060 | 2013 | 0 | 0 | 1,698 | 0 | 0 | 0 | 0 | 2 | 1 | - 0 € | - 0 € | |
| 2. HEATING SYSTEMS / 2. HEIZUNGSTECHNISCHE ANLAGEN | 9.1 Heating appliances (radiators, panel radiators, convectors) / 9.1 Heizkörper (Radiatoren, Plattenheizkörper, Konvektoren) | not applicable | 195 | 0001/HVAC | HK | HK3 | apikal | Heating | Main Staircase | 2.08 | Radiator Klimaleiste | JOCO | KlimaLeiste | 2013 | 0 | 0 | 0.334 | 0 | 0 | 0 | 0 | 28 | 1 | - 0 € | - 0 € | |
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 1.1 Fans / 1.1 Ventilatoren | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 198 | 0001/HVAC | RLT | RLT1 | Heltec | AHU1 | Roof South | 0 | Air Handling Unit AHU1 Cooling/Heating / RLT 1 | AL-KO THERM | AT4 20x16 Wetterfest | 2013 | 68.23 | 140.4 | 67.9 | 0 | 13500 | 11 | Volz Rahmenfilter | 1 | 4 | - 0 € | - 0 € | |||
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 2.5 Rotary heat exchangers / 2.5 Rotations-Wärmeübertrager | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 199 | 0001/HVAC | RLT | RLT1HE | Heltec | AHU1 | Roof South | 0 | Heat exchanger / Wärmetauscher Zuluft AHU1 | Hombach Wärmetechnik GmbH | W/12/500/1R/1 K/5.5CU,9.5/AL-L1 | 2013 | 0 | 0 | 1.94 | 0 | 720 | 0 | 0 | 1 | 4 | - 0 € | - 0 € | |||
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 1.1 Fans / 1.1 Ventilatoren | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 200 | 0001/HVAC | RLT | RLT2 | Heltec | AHU2 | Roof North | 31-Dec | Air Handling Unit AHU2 Cooling/Heating / RLT2 | AL-KO THERM | AT4 16x16 Wetterfest | 2013 | 72.55 | 106.3 | 51.3 | 0 | 10,200 | 7.5 | Volz Rahmenfilter | 1 | 4 | - 0 € | - 0 € | |||
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 2.5 Rotary heat exchanger / 2.5 Rotations-Wärmeübertrager | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||||
| by factory authorized personnel | 201 | 0001/HVAC | RLT | RLT2HE | Heltec | AHU2 | Roof North | 0 | Heat exchanger / Wärmetauscher Zuluft AHU2 | Hombach Wärmetechnik GmbH | W/12/500/1R/1 K/5.5CU,9.5/AL-L1 | 2013 | 0 | 0 | 1.94 | 0 | 720 | 0 | 0 | 1 | 4 | - 0 € | - 0 € | |||
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 1.1 Fans / 1.1 Ventilatoren | not applicable | 202 | 0001/HVAC | RLT | RLT3 | Heltec | AHU3 | Roof North (Toiletts) | 0 | Dachventilator Abluft | Systemair | DVS sileo 500DV | 2013 | 0 | 0 | 0 | 0 | 2,720 | 1.24 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 5.2 Multiple-leaf dampers / 5.2 Jalousieklappen | not applicable | 203 | 0001/HVAC | CHP | CHP Louver | Heltec | Louver BHKW | Basement | U.20 | Jalousieklappe BHKW / Louver CGP | Trox | JZ-B | 2013 | 0 | 0 | 0 | 0 | 0 | 18.5 | 0 | 1 | 1 | - 0 € | - 0 € | |
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 5.4 Fire dampers / 5.4 Brandschutzklappen | not applicable | 204 | 0001/HVAC | FPFM | FPFM 1 - 72 | Heltec | AHU1 | JOC Room | 2.05 | Fire Damper / Brandschutzklappen | Schako | RLT1-3.03-ZU-301 | 2013 | 0 | 0 | 0 | 0 | 3,270 | 0 | 0 | 72 | 1 | - 0 € | - 0 € | |
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 5.8 Air flow rate controllers / 5.8 Volumenstromregler | not applicable | 276 | 0001/HVAC | VSR | VSR-U.18 | Heltec | AHU1 | Basement | U.18 | Air Flow Controller/ | |||||||||||||||
| Volumenstromregler | Schako | Voltop R | 2013 | 0 | 0 | 0 | 0 | 250 | 0.003 | 0 | 194 | 1 | - 0 € | - 0 € | ||||||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 5.1 Fans / 5.1 Ventilatoren | not applicable | 493 | 0001/HVAC | S | AC69 | GFI | Sprinkler | Basement | U.10 | Fan Coil/ Umluftgerät | GEP | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 4 | - 0 € | - 0 € | |
| 1. VENTILATION SYSTEMS / 1. LÜFTUNGSTECHNISCHE ANLAGEN | 2.7 Chilled ceilings / 2.7 Kühldecken | not applicable | 504 | 0001/HVAC | KD | CC | Lindner | Climate | Office Areas and JOC | 0 | Einhängeheiz-/kühldecke | Lindner | Plafotherm E 200; 1.900m² | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1900m² | 1 | - 0 € | - 0 € | |
| Total / Gesamt: | 505 | - 0 € |
x
&11W912CM-16-T-0032 &11USAG Wiesbaden Gray Cyber Center, Bldg 01500 Base Year - Price Book Exhibit B1, HVAC
&D &P / &N
Exhibit_B3_Electrical BY
VDMA 24186
Maintenance instructions Chapter / Wartungsanleitung Kapitel VDMA 24186 Maintenance instructions Classification and item description / Wartungsanleitung Klassifizierung und Positions-
| Beschreibung | Additional Maintenance Requirements e.g. manufacturer's instructions/ Zusätzliche Anforderungen an die Wartung wie z.B. Herstellerangaben |
| # | CLIN/Trade / |
CLIN/Gewerk
| Unit ID | Inventory Num | Installation / | ||
| Errichter | System | |||
| Name | Location / | |||
| Einbauort | Room / | |||
| Raum | Type of Unit / Gerät | Manufacturer / Hersteller | Type/Model | Constr. |
| Year | WRG | |||
| [kW] | Cooling | |||
| [kW] | Heating | |||
| [kW] | KM-Menge | |||
| [kg] | Air Volume | |||
| [m³/h] | Electr. | |||
| [kW] | Filters | Each / | ||
| Stck | PM | |||
| p.a. | Cost Each / Kosten pro Stück [€] | Kosten Basis Jahr / Base Year |
Cost PM p.a. [€]
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2.2 Static UPS / 2.2 Statische USV | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 197 | 0003/Electr | USV | USV | Rittal | UPS | USV | U.19 | UPS Racks / USV | Rittal | Rittal PMC 200 1,6MW | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 505 | 0003/Electr | NEA | NEA1 | Stiegele | Emergency Generator | NEA | Ext | Engine / Dieselmotor | MTU | 16V 4000 G63 | 2013 | 1,965 | 1 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 506 | 0003/Electr | NEA | NEA2 | Stiegele | Emergency Generator | NEA | Ext | Generator | MarelliGenerators | MJB 500 LA4 | 2013 | 1,965 | 1 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 507 | 0003/Electr | NEA | NEA3 | Stiegele | Emergency Generator switch system | NEA | Ext | Spannungsregler | MarelliGenerators | M40FA640A/A Mark I | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 508 | 0003/Electr | NEA | NEA4 | Stiegele | Emergency Generator switch system | NEA | Ext | Aggregatesteuerung | WOODWARD | easYgen-3500 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 1.3 Low-voltage main distributors / 1.3 Niederspannungshauptverteilungen | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 509 | 0003/Electr | NEA | NEA5 | Stiegele | Emergency Generator switch system | NEA | Ext | Niederspannungsleitungsschalter | ABB | Emax | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 1.3 Low-voltage main distributors / 1.3 Niederspannungshauptverteilungen | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 510 | 0003/Electr | NEA | NEA6 | Stiegele | Emergency Generator switch system | NEA | Ext | Niederspannungs Kompaktleitungsschalter | ABB | Tmax T5 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 511 | 0003/Electr | NEA | NEA7 | Stiegele | Emergency Generator switch system | NEA | Ext | Synchronisiersperrelais | Deif | CSQ-3 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 512 | 0003/Electr | NEA | NEA8 | Stiegele | Emergency Generator switch system | NEA | Ext | Lighting / Beleuchtung | Rittal | SZ 4138.140/180/300 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 513 | 0003/Electr | NEA | NEA9 | Stiegele | Emergency Generator switch system | NEA | Ext | Digitale Erweiterungskarte | WOODWARD | IKD 1 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 514 | 0003/Electr | NEA | NEA10 | Stiegele | Emergency Generator switch system | NEA | Ext | Circuit Breaker Control / Sicherungskontrollsystem | WOODWARD | LS-511/521 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2.4 Battery and charging equipment / 2.4 Batterie- und Ladeeinrichtung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 515 | 0003/Electr | NEA | NEA11 | Stiegele | Emergency Generator | NEA | Ext | Batteries / Bleibatterien | HOPPECKE | 2013 | 1 | 2 | - 0 € | - 0 € | |||||||||
| 3. REFRIGERATING SYSTEMS / 3. KÄLTETECHNISCHE ANLAGEN | 2.3 Air-cooled condensers / 2.3 Luftgekühlte Verflüssiger | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 516 | 0003/Electr | NEA | NEA12 | Stiegele | Emergency Generator AHU | NEA | Ext | Cooling System / Tischkühler | GEA | DKG245-6D | 2013 | 550-913 | max.198.000 | max. 2,45 | 1 | 1 | - 0 € | - 0 € | |||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 517 | 0003/Electr | NEA | NEA13 | Stiegele | Emergency Generator | NEA | Ext | Oil Air Cooling / Öl-Luft Kühler | ADAM | E-Motor K21R 71 G 4 | 2013 | 0.37 | 1 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 518 | 0003/Electr | NEA | NEA14 | Stiegele | Emergency Generator | NEA | Ext | Öl Pumpenaggregat | Stiegele | KPA(D) 30-15.x | 2013 | 0.72 | 1 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 519 | 0003/Electr | NEA | NEA15 | Stiegele | Emergency Generator | NEA | Ext | Leak Detection / Unterdruck Leckanzeiger | SGB | VL Z-65.22-389 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 520 | 0003/Electr | NEA | NEA16 | Stiegele | Emergency Generator | NEA | Ext | Auto Shut Off / Grenzwertgeber | AFRISO | GWG 23-WA,T | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 521 | 0003/Electr | NEA | NEA17 | Stiegele | Emergency Generator | NEA | Ext | Leak Detection / Unterdruck Leckanzeiger | BRUGG | Flexwell VLR | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 522 | 0003/Electr | NEA | NEA18 | Stiegele | Emergency Generator | NEA | Ext | Auto Shut Off System / Überfüll Sicherung | FAFNIR | 76/NB 220 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 523 | 0003/Electr | NEA | NEA19 | Stiegele | Emergency Generator | NEA | Ext | Leak Detection Oil / Öl Leckwarnmelder | AFRISO | OM5 | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 524 | 0003/Electr | NEA | NEA20 | Stiegele | Emergency Generator | NEA | Ext | AST Day Tank/ | |||||||||||||||
| Tages Öltank | Martin ADAM | 1.000l/ 4709S | 2013 | 1 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 2 Standby power / 2 Ersatzstromversorgung | maintenance according to the manufacturer's instructions | ||||||||||||||||||||||
| by factory authorized personnel | 525 | 0003/Electr | NEA | NEA21 | Stiegele | Emergency Generator | Exterior | Ext | Underground storage tank/ | |||||||||||||||
| Erdeingebauter Öltank | Altmayer BTD | 30.000Liter 50/ 160923 | 2013 | 1 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 526 | 0003/Electr | KitchenEquip | DW1 | Dishwasher | Kitchen / Küche | 1.13 | Dishwasher / Geschirrspüler | Siemens | SN | 2013 | 1 | 1 | - 0 € | - 0 € | |||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 527 | 0003/Electr | KitchenEquip | DW2 | Dishwasher | Kitchen / Küche | 1.13 | Dishwasher / Geschirrspüler | Siemens | SN | 2013 | 1 | 1 | - 0 € | - 0 € | |||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 528 | 0003/Electr | KitchenEquip | RF1 | Refrigerator | Kitchen / Küche | 2.13 | Refrigerator / Kühlschrank | Siemens | KI..L | 2013 | 2 | 1 | - 0 € | - 0 € | |||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 529 | 0003/Electr | KitchenEquip | RF2 | Refrigerator | Kitchen / Küche | 2.13 | Refrigerator / Kühlschrank | Siemens | KI..L | 2013 | 2 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 5.1 Central and group battery installations (emergency lighting) / 5.1 Zentral- und Gruppen-Batterieanlagen (Notbeleuchtung) | not applicable | 571 | 0003/Electr | SIBE | SIBE1 | Zeka | Emergancy lighting | Central Battery System / Batterie | COOPER SAFETY | ZB-S with STAR-Tech | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 5.1 Central and group battery installations (emergency lighting) / 5.1 Zentral- und Gruppen-Batterieanlagen (Notbeleuchtung) | not applicable | 572 | 0003/Electr | SIBE | SIBE2 | Zeka | Emergancy lighting | Escape sign Luminaire / Sicherbeleuchtung | COOPER SAFETY | 71011…71021 LED CG-S | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 5.1 Central and group battery installations (emergency lighting) / 5.1 Zentral- und Gruppen-Batterieanlagen (Notbeleuchtung) | not applicable | 573 | 0003/Electr | SIBE | SIBE3 | Zeka | Emergancy lighting | Escape sign ceiling mounting / Pictogramm Deckenbesfestigung | COOPER SAFETY | GuideLED 10021-10024 CG-S | 2013 | 20 | 1 | - 0 € | - 0 € | ||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 5.1 Central and group battery installations (emergency lighting) / 5.1 Zentral- und Gruppen-Batterieanlagen (Notbeleuchtung) | not applicable | 574 | 0003/Electr | SIBE | SIBE4 | Zeka | Emergancy lighting | Escape sign Wall mounting / Pictogramm Wandbefestigung | COOPER SAFETY | GuideLED 11011-11013 CG-S | 2013 | 20 | 1 | - 0 € | - 0 € | ||||||||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 575 | 0003/Electr | SOS | SOS | Zeka | SOS | Handicapped | Emergency call system/ | ||||||||||||||
| Notrufanlage | Schneider Electric | ELSO SIGMA | 2013 | 1 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 1.3 Low-voltage main distributors / 1.3 Niederspannungshauptverteilungen | not applicable | 600 | 0003/Electr | ELE | SSA1 | Zeka | Starkstromanlage | NSHV | Low-voltage Main Distribution Board / NSHV | 2013 | 1 | 1 | - 0 € | - 0 € | |||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 3.3 Electrical distribution boards / 3.3 Elektroverteiler | not applicable | 601 | 0003/Electr | ELE | SSA2 | Zeka | Starkstromanlage | Office Areas and JOC | subdistribution / Unterverteilungen UV | 2013 | 21 | 1 | - 0 € | - 0 € | |||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 1.5 Grounding and lightning protection / 1.5 Erdung und Blitzschutz | not applicable | 602 | 0003/Electr | ELE | SSA3 | Zeka | Starkstromanlage | Over voltage Protection / Überspannungsschutz | 2013 | 9 | 1 | - 0 € | - 0 € | ||||||||||
| 4. I&C EQUIPMENT AND BUILDING AUTOMATION SYSTEMS / 4. MSR-EINRICHTUNGEN UND GEBÄUDEAUTOMATIONSSYSTEME | 5.1 Substations / 5.1 Unterstationen | not applicable | 603 | 0003/Electr | ELE | SSA4 | Zeka | Starkstromanlage | ISP / Überspannungsschutz | 2013 | 3 | 1 | - 0 € | - 0 € | ||||||||||
| 4. I&C EQUIPMENT AND BUILDING AUTOMATION SYSTEMS / 4. MSR-EINRICHTUNGEN UND GEBÄUDEAUTOMATIONSSYSTEME | 3.3 Decentralized bus-compatible assemblies (LON, EIB, etc.) / 3.3 Dezentrale busfähige Baugruppen (LON, EIB etc.) | not applicable | 604 | 0003/Electr | ELE | SEC1 | Zeka | EIB KNX | Motion sensor / Bewegungsmelder | 2013 | 234 | 1 | - 0 € | - 0 € | ||||||||||
| 4. I&C EQUIPMENT AND BUILDING AUTOMATION SYSTEMS / 4. MSR-EINRICHTUNGEN UND GEBÄUDEAUTOMATIONSSYSTEME | 3.3 Decentralized bus-compatible assemblies (LON, EIB, etc.) / 3.3 Dezentrale busfähige Baugruppen (LON, EIB etc.) | not applicable | 605 | 0003/Electr | ELE | EIB | Zeka | EIB KNX | EIB KNX | 2013 | 1 | 1 | - 0 € | - 0 € | ||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 612 | 0003/Electr | SS | SP-1.15 | Zeka/ Nelilux | Sun Protection | Office | 1.15 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 8 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 613 | 0003/Electr | SS | SP-1.01 | Zeka/ Nelilux | Sun Protection | Office | 1.01 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 14 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 614 | 0003/Electr | SS | SP-1.03 | Zeka/ Nelilux | Sun Protection | Office | 1.03 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 10 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 615 | 0003/Electr | SS | SP-1.17 | Zeka/ Nelilux | Sun Protection | Office | 1.17 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 12 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 616 | 0003/Electr | SS | SP-2.15 | Zeka/ Nelilux | Sun Protection | Office | 2.15 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 8 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 617 | 0003/Electr | SS | SP-2.01 | Zeka/ Nelilux | Sun Protection | Office | 2.01 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 14 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 618 | 0003/Electr | SS | SP-2.03 | Zeka/ Nelilux | Sun Protection | Office | 2.03 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 10 | 1 | - 0 € | - 0 € | |||||||||||||||||
| not applicable / not applicable | not applicable / not applicable | maintenance according to the manufacturer's instructions | 619 | 0003/Electr | SS | SP-2.17 | Zeka/ Nelilux | Sun Protection | Office | 2.17 | internal sun shading/ | |||||||||||||
| innenliegender Sonnenschutz | Warema | E 60 AF A6 | 2013 | 12 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 717 | 0003/Electr | BL | Light1 | ZEKA | Light | Basement | Lineare fluorescent luminaire Type A / | ||||||||||||||
| Linear Beleuchtung | TRILUX | Oleveon 1x49W | 2013 | 80 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 718 | 0003/Electr | BL | Light2 | ZEKA | Light | Basement | U.12 | Lineare fluorescent luminaire Type B / | |||||||||||||
| Linear Beleuchtung | TRILUX | Oleveon 2x58W | 2013 | 4 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 719 | 0003/Electr | BL | Light3 | ZEKA | Light | Basement | U.02; U.16 | Ceiling light fixture Type C / Deckenleuchte | TRILUX | Inperla CS DA 01 2x42W | 2013 | 4 | 1 | - 0 € | - 0 € | ||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 720 | 0003/Electr | BL | Light4 | ZEKA | Light | 1st Floor | Office | Luminary Type A /Beleuchtung | RIDI | EBRME 414/24 OS-EVG 4x26W | 2013 | 250 | 1 | - 0 € | - 0 € | ||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 721 | 0003/Electr | BL | Light5 | ZEKA | Light | 1st Floor | 1.04 | Lineare fluorescent luminaire Type B / | |||||||||||||
| Linear Beleuchtung | Philips | EFIX; TCS260 2x49W | 2013 | 96 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 722 | 0003/Electr | BL | Light6 | ZEKA | Light | 1st Floor | Lineare fluorescent luminaire Type C / | ||||||||||||||
| Linear Beleuchtung | TRILUX | Oleveon 1x49W | 2013 | 3 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 723 | 0003/Electr | BL | Light7 | ZEKA | Light | 1st Floor | Lineare fluorescent luminaire Type D / | ||||||||||||||
| Linear Beleuchtung | TRILUX | Oleveon 2x58W | 2013 | 4 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 724 | 0003/Electr | BL | Light8 | ZEKA | Light | 1st Floor | Ceiling light fixture Type E / Deckenleuchte | TRILUX | Inperla CS DA 01 2x42W | 2013 | 25 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 725 | 0003/Electr | BL | Light9 | ZEKA | Light | 1st Floor | Ceiling light fixture Type F / Deckenleuchte | TRILUX | Inperla C2 HR 1TCT 18W | 2013 | 26 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 726 | 0003/Electr | BL | Light10 | ZEKA | Light | 1st Floor | Ext | Ceiling light fixture Type G / Deckenleuchte | TRILUX | Inperla C2 HR 1TCT 26W | 2013 | 8 | 1 | - 0 € | - 0 € | ||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 727 | 0003/Electr | BL | Light11 | ZEKA | Light | 2nd Floor | Office | Luminary Type A / Beleuchtung | RIDI | EBRME 414/24 OS-EVG 4x26W | 2013 | 250 | 1 | - 0 € | - 0 € | ||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 728 | 0003/Electr | BL | Light12 | ZEKA | Light | 2nd Floor | Lineare fluorescent luminaire Type C / | ||||||||||||||
| Linear Beleuchtung | TRILUX | Oleveon 1x49W | 2013 | 1 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 729 | 0003/Electr | BL | Light13 | ZEKA | Light | 2nd Floor | Lineare fluorescent luminaire Type D / | ||||||||||||||
| Linear Beleuchtung | TRILUX | Oleveon 2x58W | 2013 | 4 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 730 | 0003/Electr | BL | Light14 | ZEKA | Light | 2nd Floor | Ceiling light fixture Type E / | ||||||||||||||
| Deckenleuchte | TRILUX | Inperla CS DA 01 2x42W | 2013 | 24 | 1 | - 0 € | - 0 € | |||||||||||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 731 | 0003/Electr | BL | Light15 | ZEKA | Light | 2nd Floor | Ceiling light fixture Type F / Deckenleuchte | TRILUX | Inperla C2 HR 1TCT 18W | 2013 | 26 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 732 | 0003/Electr | BL | Light16 | ZEKA | Light | 2nd Floor | 2.06; 2.07 | Lineare fluorescent luminaire Type H / Linear Beleuchtung | SITECO | Novaluna 2x 49W | 2013 | 30 | 1 | - 0 € | - 0 € | ||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 733 | 0003/Electr | BL | Light17 | ZEKA | Light | 3rd Floor | Ceiling light fixture Type E / Deckenleuchte | TRILUX | Inperla CS DA 01 2x42W | 2013 | 24 | 1 | - 0 € | - 0 € | |||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 734 | 0003/Electr | BL | Light18 | ZEKA | Light | 3rd Floor | 2.05 | Lineare fluorescent luminaire Type H / Linear Beleuchtung | SITECO | Novaluna 2x 49W | 2013 | 73 | 1 | - 0 € | - 0 € | ||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 4.2 Lighting / 4.2 Beleuchtungen | not applicable | 735 | 0003/Electr | BL | Light19 | ZEKA | Light | 3rd Floor | Spotlight outside | 2013 | 9 | 1 | - 0 € | - 0 € | |||||||||
| 5. ELECTRICAL INSTALLATIONS / 5. ELEKTROTECHNISCHE ANLAGEN | 1.5 Grounding and lightning protection / 1.5 Erdung und Blitzschutz | not applicable | 736 | 0003/Electr | BS | LP | Hinthertür | Lightning Protection | Trennstellen/ Separation Point | 2013 | 63 | 1 | - 0 € | - 0 € | ||||||||||
| Total / Gesamt: | 1393 | - 0 € | ||||||||||||||||||||||
| x |
&11W912CM-16-T-0032 &11USAG Wiesbaden Gray Cyber Center, Bldg 01500 Base Year - Price Book Exhibit B3, Electrical
&D &P / &N
Exhibit_B4_FireSuppressionS BY
VDMA 24186
Maintenance instructions Chapter / Wartungsanleitung Kapitel VDMA 24186 Maintenance instructions Classification and item description / Wartungsanleitung Klassifizierung und Positions-
| Beschreibung | Additional Maintenance Requirements e.g. manufacturer's instructions/ Zusätzliche Anforderungen an die Wartung wie z.B. Herstellerangaben |
| # | CLIN/Trade / |
CLIN/Gewerk
| Unit ID | Inventory Num | Installation / | ||
| Errichter | System | |||
| Name | Location / | |||
| Einbauort | Room / | |||
| Raum | Type of Unit / Gerät | Manufacturer / Hersteller | Type/Model | Constr. |
| Year | WRG | |||
| [kW] | Cooling | |||
| [kW] | Heating | |||
| [kW] | KM-Menge | |||
| [kg] | Air Volume | |||
| [m³/h] | Electr. | |||
| [kW] | Filters | Each / | ||
| Stck | PM | |||
| p.a. | Cost Each / Kosten pro Stück [€] | Kosten Basis Jahr / Base Year |
Cost PM p.a. [€]
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 4.4 Wet control valve sets / 4.4 Nass-Alarmventilstationen | not applicable | 484 | 0004/FireSup | S | V1-2 | GFI | Sprinkler | Basement | U.10 | Wet System Valve Assemblies / Nass Alarm | TYCO | AV-1-300 EUR / FM | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 2 | - 0 € | - 0 € | |
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8 Fire detection and alarm systems / 8 Brandmeldeanlagen | not applicable | 486 | 0004/FireSup | S | SIT1 | GFI | Sprinkler | Basement | U.10 | FMZ / Control Unit | LST | Serie BC016 | 2013 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 3.3 Pressure maintenance pumps and tanks / 3.3 Druckhaltepumpen und -behälter | not applicable | 487 | 0004/FireSup | S | Boost | GFI | Sprinkler | Basement | U.10 | Booster Station/ | |||||||||||||||
| Trennstation | GEP | 313 4RE | 2013 | 0 | 0 | 0 | 0 | 0 | 2x18 | 0 | 1 | 2 | - 0 € | - 0 € | ||||||||||||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 3.3 Pressure maintenance pumps and tanks / 3.3 Druckhaltepumpen und -behälter | not applicable | 488 | 0004/FireSup | S | SIT2 | GFI | Sprinkler | Basement | U.10 | Separating Station-Control | GEP | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 3.3 Pressure maintenance pumps and tanks / 3.3 Druckhaltepumpen und -behälter | not applicable | 489 | 0004/FireSup | S | P1 | GFI | Sprinkler | Basement | U.10 | Fire PumpFeuerlöschpumpe | GEP/DANFOSS | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 3.3 Pressure maintenance pumps and tanks / 3.3 Druckhaltepumpen und -behälter | not applicable | 490 | 0004/FireSup | S | P2 | GFI | Sprinkler | Basement | U.10 | Fire PumpFeuerlöschpumpe | GEP/DANFOSS | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 4.3 Pressure tanks/pressure maintenance pumps / 4.3 Druckluftwasserbehälter/Druckhaltepumpen | not applicable | 491 | 0004/FireSup | S | C1 | GFI | Sprinkler | Basement | U.10 | Doppelkompressor | GEP | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 4.3 Pressure tanks/pressure maintenance pumps / 4.3 Druckluftwasserbehälter/Druckhaltepumpen | not applicable | 492 | 0004/FireSup | S | C2 | GFI | Sprinkler | Basement | U.10 | Kompressor | GEP | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | |
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 3.3 Pressure maintaining pumps and tanks / 3.3 Druckhaltepumpen und -behälter | not applicable | 494 | 0004/FireSup | S | P3 | GFI | Sprinkler | Basement | U.10 | Pressure Maintenance/ | |||||||||||||||
| Druckhaltepumpe | GEP/DANFOSS | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 2 | - 0 € | - 0 € | ||||||||||||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 4.10 Water flow detectors / 4.10 Strömungsmelder | not applicable | 496 | 0004/FireSup | S | FC1 - 8 | GFI | Fire Control | Basement | Schacht 7 | Flow Switch/ | |||||||||||||||
| Strömungsmelder | Minimax | ZONECHECK | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8 | 2 | - 0 € | - 0 € | ||||||||||||
| Total / Gesamt: | 19 | - 0 € |
x
&11W912CM-16-T-0032 &11USAG Wiesbaden Gray Cyber Center, Bldg 01500 Base Year - Price Book Exhibit B4, Fire Suppression System
&D &P / &N
Exhibit_B5_Fire AlarmSystem_BY
VDMA 24186
Maintenance instructions Chapter / Wartungsanleitung Kapitel VDMA 24186 Maintenance instructions Classification and item description / Wartungsanleitung Klassifizierung und Positions-
| Beschreibung | Additional Maintenance Requirements e.g. manufacturer's instructions/ Zusätzliche Anforderungen an die Wartung wie z.B. Herstellerangaben |
| # | CLIN/Trade / |
CLIN/Gewerk
| Unit ID | Inventory Num | Installation / | ||
| Errichter | System | |||
| Name | Location / | |||
| Einbauort | Room / | |||
| Raum | Type of Unit / Gerät | Manufacturer / Hersteller | Type/Model | Constr. |
| Year | WRG | |||
| [kW] | Cooling | |||
| [kW] | Heating | |||
| [kW] | KM-Menge | |||
| [kg] | Air Volume | |||
| [m³/h] | Electr. | |||
| [kW] | Filters | Each / | ||
| Stck | PM | |||
| p.a. | Cost Each / Kosten pro Stück [€] | Kosten Base Year / Base Year |
Cost PM p.a. [€]
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 530 | 0005/FireAlarm | BM | SHE 1.21a | Zeka | Fire Control | Fire Alarm Center | 1.21 | Überwachungsmodule | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 1 | - 0 € | - 0 € | ||||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 531 | 0005/FireAlarm | BM | SHE 1.21b | Zeka | Fire Control | Fire Alarm Center | 1.21 | Filterlüfter | Striebel&John | RFZ100 RFZ200 | 2013 | 0 | 0 | 0 | 0 | 15-40 | RZA100 RZA200 | 1 | 1 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 532 | 0005/FireAlarm | BM | SHE 1.21c | Zeka | Fire Control | Fire Alarm Center | 1.21 | Switch / Leistungsschalter, Trennschalter | ABB | SACE Emax | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 533 | 0005/FireAlarm | BM | FC1 | Zeka | Fire Control | Server Farm | 1.04 | Venturi Air Duct Kit | Esser | 781443 | 2013 | 0 | 0 | 0 | 0 | 0 | 781444 | 1 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 534 | 0005/FireAlarm | BM | FC2 | Zeka | Fire Control | Server Farm | 1.04 | Smoke aspirating system | Esser | LRS compact/EB 801519 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 535 | 0005/FireAlarm | BM | FC3 | Zeka | Fire Control | Main Staircase | 1.08 | Alarm Control Panel / BMA | Esser | IQ8Control C/M | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 536 | 0005/FireAlarm | BM | FC4 | Zeka | Fire Control | 0 | 0 | O2T Melder | Esser | Fire Detector IQ8Quad | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 37 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 537 | 0005/FireAlarm | BM | FC5 | Zeka | Fire Control | 0 | 0 | Analog Ring Modul | Esser | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 4 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 538 | 0005/FireAlarm | BM | FC6 | Zeka | Fire Control | 0 | 0 | Peripheriemodul | Esser | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 539 | 0005/FireAlarm | BM | FC7 | Zeka | Fire Control | 0 | 0 | Esserbus-Koppler transponder 32AE | Esser | 808611.10 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 540 | 0005/FireAlarm | BM | FC8 | Zeka | Fire Control | 0 | 0 | Esserbus-Koppler transponder 4ln/2AE | Esser | 808613 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 29 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 541 | 0005/FireAlarm | BM | FC9 | Zeka | Fire Control | 0 | 0 | TD-Melder | Esser | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 39 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 542 | 0005/FireAlarm | BM | FC10 | Zeka | Fire Control | 0 | 0 | O-Melder | Esser | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 543 | 0005/FireAlarm | BM | FC11 | Zeka | Fire Control | 0 | 0 | OT-Melder | Esser | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 4 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 544 | 0005/FireAlarm | BM | FC12 | Zeka | Fire Control | 0 | 0 | Meldersockel | Esser | 0 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 82 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 545 | 0005/FireAlarm | BM | FC13 | Zeka | Fire Control | 0 | 0 | Lüftungkanalmelder | Esser | 781443 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 4 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 546 | 0005/FireAlarm | BM | FC14 | Zeka | Fire Control | 0 | 0 | Fire Detector Manuel /Handmelder | Esser | IQ8 Handmelder | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 34 | 4 | - 0 € | - 0 € | ||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 547 | 0005/FireAlarm | BM | FC15 | Zeka | Fire Control | 0 | 0 | Blitzleuchte klar | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 92 | 4 | - 0 € | - 0 € | ||||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 548 | 0005/FireAlarm | BM | FC16 | Zeka | Fire Control | 0 | 0 | Key Depot / Feuerwehrschlüsseldepot | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 4 | - 0 € | - 0 € | ||||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 549 | 0005/FireAlarm | BM | FC17 | Zeka | Fire Control | 0 | 0 | Flash Lights / Blitzleuchte amber | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 4 | 4 | - 0 € | - 0 € | ||||
| 7. FIRE SAFETY SYSTEMS / 7. BRANDSCHUTZTECHNISCHE ANLAGEN | 8.1 Fire detection and alarm systems / 8.1 Brandmeldeanlagen | not applicable | 550 | 0005/FireAlarm | BM | FC18 | Zeka | Fire Control | 0 | 0 | FAT 3000 | 2013 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 4 | - 0 € | - 0 € |