US Army Corps of Engineers ®
TULSA DISTRICT
TULSA, OKLAHOMA
KC-46A TWO-BAY DEPOT MAINTENANCE HANGAR
5 6
D
C
A
B
1 2 3 4
E
C O
P Y
R
IG
H T
B
U R
N S
M c D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
TINKER AIR FORCE BASE, OKLAHOMA
CONTRACT NUMBER:
SOLICITATION NUMBER: W912BV-16-R-0001
PDC: HANGAR: WWYK153005
/1
/2
:3 :2
P
M
READY TO ADVERTISEJANUARY 2016
VOLUME 3 OF 3
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/2
0/
9:
:2
AM
/0
8/
G-005
M
EC
H B
U
IL
D
IN
G S
H
EE
T
IN
D
EX
V O
LU
M
E
R . T
H O
M
PS
O N C he ck er
W W
YK
0 5
G -0
.D
W G
Ap pr ov er
MECHANICAL BUILDING - STRUCTURAL
SHEET
NUMBER SHEET NAME
S-001M GENERAL NOTES
S-002M ABBREVIATIONS AND KEY
S-003M STATEMENT OF SPECIAL INSPECTIONS
S-004M STATEMENT OF SPECIAL INSPECTIONS
S-005M WIND ISO DIAGRAM
S-006M WIND ISO DIAGRAM
S-007M STANDARD FOUNDATION DETAILS
S-008M STANDARD CONCRETE DETAILS
S-009M STANDARD SLAB ON GRADE DETAILS
S-010M STANDARD MASONRY DETAILS
S-011M STANDARD STEEL DETAILS
S-100M FOUNDATION AND SLAB PLAN
S-101M ROOF FRAMING PLAN
S-200M ELEVATIONS
S-201M ELEVATIONS
S-300M DEEP FOUNDATION DETAILS AND SCHEDULE
S-301M FOUNDATION DETAILS
S-302M FOUNDATION DETAILS
S-303M PIPE PIT DETAILS
S-304M MECHANICAL COURTYARD PLAN AND DETAILS
S-305M TANK AND PIPE FOUNDATION PLAN
S-400M COLUMN SCHEDULE AND DETAILS
S-401M FRAMING DETAILS
S-420M VERTICAL BRACING DETAILS
MECHANICAL BUILDING - ARCHITECTURAL
SHEET
NUMBER SHEET NAME
AE001M ARCHITECTURAL LEGEND, ABBREVIATIONS, AND GENERAL NOTES
AB101M AIR BARRIER EXTENTS AND LIMITS - FLOOR PLAN
AB301M AIR BARRIER EXTENTS AND LIMITS - BUILDING SECTIONS
AE110M OVERALL FLOOR PLAN
AE120M OVERALL REFLECTED CEILING PLAN
AE130M OVERALL ROOF PLAN
AE201M EXTERIOR BUILDING ELEVATIONS
AE202M EXTERIOR BUILDING ELEVATIONS
AE301M BUILDING SECTIONS
AE311M WALL SECTIONS
AE401M ENLARGED TOILET ROOM PLANS AND ELEVATIONS
AE402M GUARDRAIL ELEVATIONS, LADDER AND GUARDRAIL DETAILS
AE501M PARTITION TYPES AND DETAILS
AE502M PENETRATION DETAILS
AE551M DETAILS
AE601M DOOR SCHEDULE, DOOR AND FRAME TYPES, DOOR DETAILS
AE631M LOUVER SCHEDULE AND LOUVER TYPES
AE701M ROOM FINISH AND SIGNAGE PLAN, ROOM FINISH SCHEDULE
I-110M OVERALL FURNITURE PLAN
MECHANICAL BUILDING - FIRE PROTECTION
SHEET
NUMBER SHEET NAME
F-101M LIFE SAFETY PLAN
FA101M FIRE ALARM PLAN
FA601M FIRE ALARM RISER AND MATRIX
FX101M FIRE SUPPRESSION PLAN
FX501M FIRE SUPPRESSION ENLARGED PLANS
FX601M FIRE SUPPRESSION ONE LINE DIAGRAM
MECHANICAL BUILDING - PLUMBING
SHEET
NUMBER SHEET NAME
P-001M PLUMBING LEGEND AND ABBREVIATIONS
P-100M PLUMBING PLAN - BELOW GRADE
P-101M PLUMBING PLAN - GROUND FLOOR
P-111M PLUMBING ENLARGED PLANS
P-501M PLUMBING DETAILS
P-502M PLUMBING DETAILS
P-601M PLUMBING SCHEDULES
P-701M PLUMBING RISER DIAGRAM
P-702M PLUMBING RISER DIAGRAM
MECHANICAL BUILDING - MECHANICAL
SHEET
NUMBER SHEET NAME
M-001M MECHANICAL LEGEND AND ABBREVIATIONS
M-100M MECHANICAL HVAC FLOOR PLAN
M-110M MECHANICAL PIPING FLOOR PLAN
M-111M MECHANICAL PIPING ENLARGED PLAN
M-112M MECHANICAL PIPING ENLARGED PLAN
M-113M MECHANICAL PIPING ENLARGED PLAN
M-114M MECHANICAL PIPING ENLARGED PLAN
M-301M MECHANICAL SECTIONS
M-302M MECHANICAL SECTIONS
M-303M MECHANICAL SECTIONS
M-304M MECHANICAL SECTIONS
M-305M MECHANICAL SECTIONS
M-501M MECHANICAL DETAILS
M-502M MECHANICAL DETAILS
M-503M MECHANICAL DETAILS
M-504M MECHANICAL DETAILS
M-601M MECHANICAL SCHEDULES
M-602M MECHANICAL SCHEDULES
M-603M MECHANICAL SCHEDULES
MECHANICAL BUILDING - ELECTRICAL
SHEET
NUMBER SHEET NAME
E-001M ELECTRICAL SYMBOLS LEGEND & ABBREVIATIONS
EG101M GROUNDING PLAN
EG102M LIGHTNING PROTECTION SCOPE PLAN
EG103M LIGHTNING PROTECTION SYSTEM ROOF PLAN
EG501M GROUNDING DETAILS
EG601M TYPICAL GROUNDING RISER SCHEMATIC
EL101M LIGHTING PLAN
EL501M LIGHTING DETAILS
EL502M LIGHTING DETAILS
EL601M LIGHTING SCHEDULES
EP101M POWER PLAN
EP401M ENLARGED POWER PLANS
EP501M POWER DETAILS
EP601M ONE-LINE DIAGRAM-A
EP602M ONE-LINE DIAGRAM -B AND FIRE PROTECTION ONE-LINE
EP701M PANELBOARD SCHEDULES
EP721M MECHANICAL EQUIPMENT SCHEDULES
MECHANICAL BUILDING - TELECOMMUNICATION
SHEET
NUMBER SHEET NAME
T-001M COMMUNICATIONS LEGEND
TN101M COMMUNICATIONS PLAN
TN501M COMMUNICATIONS DETAILS
GENERAL MECH BUILDING
SHEET
NUMBER SHEET NAME
G-002 COVER - VOLUME 3
G-005 MECH BUILDING SHEET INDEX VOLUME 3
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
1. GENERAL:
A. THESE NOTES, AND OTHER DRAWING NOTES CONTAINED WITHIN, ARE PROVIDED
TO MEET SPECIFIC REQUIREMENTS AND TO SUPPLEMENT THE CONTRACT
SPECIFICATIONS. THESE NOTES NEITHER REPLACE NOR OVERRIDE THE
PROVISIONS AND REQUIREMENTS OF THE CONTRACT SPECIFICATIONS.
B. CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH WORK SHOWN
ON ALL OTHER DRAWINGS.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS OF EXISTING CONSTRUCTION AND
REPORT ANY DISCREPANCIES FROM THE CONTRACT DRAWINGS
TO THE CONTRACTING OFFICER PRIOR TO COMMENCING
WITH WORK. SCALING OF WORKING DIMENSIONS FROM THE STRUCTURAL
DRAWINGS IS PROHIBITED.
D. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS
OF CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, SHORING AND TEMPORARY
BRACING. CONTRACTOR SHALL UNDERTAKE ALL NECESSARY MEASURES TO ENSURE
SAFETY OF ALL PERSONS AND STRUCTURES AT THE SITE AND ADJACENT TO THE SITE.
VISITS TO THE SITE BY THE CONTRACTING OFFICER OR THE ENGINEER SHALL NOT
RELIEVE THE CONTRACTOR OF SUCH RESPONSIBILITY.
E. IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR CALLED FOR ON THE CONTRACT
DRAWINGS OR SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE SAME
CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR, WITH
THE APPROVAL OF THE CONTRACTING OFFICER. WHERE SECTIONS VARY,
CONTRACTOR SHALL PROVIDE FOR SMOOTH TRANSITIONS BETWEEN THEM, UNLESS
NOTED OTHERWISE.
F. ALL PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS'
WRITTEN INSTRUCTIONS AND RECOMMENDATIONS, UNLESS NOTED OTHERWISE.
G. ELEVATION 100'-0" CORRESPONDS TO MSL ELEVATION 1278.00.
2. DESIGN STANDARDS
A. PRINCIPAL CODE OF RECORD: INTERNATIONAL BUILDING CODE 2012 AS MODIFIED
BY UFC 1-200-01 AND UFC 3-301-01.
B. ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, 2010.
C. ACI 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2011.
D. ACI 530/ASCE 5/TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES, 2011.
E. AISC STEEL CONSTRUCTION MANUAL, 14th EDITION, 2010.
F. AISI COLD-FORMED STEEL DESIGN MANUAL, 2007.
G. TINKER AIR FORCE BASE FACILITY STANDARDS.
F. SNOW LOAD
1. GROUND SNOW LOAD: 10 PSF.
2. EXPOSURE FACTOR: 1.0.
3. IMPORTANCE FACTOR: 1.2.
4. THERMAL FACTOR: 1.0.
G. WIND LOAD
1. BASIC WIND SPEED: 120 MPH
2. EXPOSURE CATEGORY: C.
3. BUILDING CONDITION: ENCLOSED
4. TOPOGRAPHIC FACTOR: 1.0.
5. DESIGN PRESSURES FOR COMPONENTS AND CLADDING OF ROOF ARE INDICATED
ON DRAWING S-005M AND S-006M.
H. SEISMIC LOAD
1. MAXIMUM CONSIDERED EARTHQUAKE SPECTRAL RESPONSE ACCELERATIONS Ss = 0.35, S1 = 0.09.
2. DESIGN SPECTRAL ACCELERATION PARAMETERS: Sds = 0.280, Sd1 = 0.102
3. IMPORTANCE FACTOR: 1.5.
3. SITE CLASS: C.
4. SEISMIC DESIGN CATEGORY: C.
5. BASIC SEISMIC FORCE RESISTING SYSTEM: STEEL SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
6. RESPONSE MODIFICATION FACTOR: R = 3.0.
7. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE.
J. THERMAL LOADS
1. DESIGN TEMPERATURE CHANGE: 37 DEGREES FAHRENHEIT
5. GEOTECHNICAL INFORMATION
A. SOURCE: SUBSURFACE INVESTIGATION: PERFORMED BY STANDARD TESTING AND ENGINEERING.
GEOTECHNICAL RECOMMENDATIONS: W2 ENGINEERING EVALUATION FINAL REPORT, NOVEMBER 8, 2014.
B. SITE PREPARATION:
1. EXCAVATION, FILL, AND BACKFILL SHALL BE IN ACCORDANCE WITH THE CONTRACT
DRAWINGS AND SPECIFICATIONS, DIVISION 31.
2. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER WHEN LOOSE OR SOFT
SOILS ARE EXPOSED WHERE SLABS, MATS, OR FOOTINGS ARE TO BE PLACED SO
THAT A DETERMINATION MAY BE MADE REGARDING IMPROVEMENT OF THIS
POTENTIALLY UNDESIRABLE CONDITION.
C. SOIL CHARACTERISTICS:
1. UNIT WEIGHT: 125 PCF (SHALE ROCK)
2. OBSERVED WATER TABLE DEPTH: NOT ENCOUNTERED DURING DRILLING
D. LATERAL EARTH PRESSURE:
1. AT REST COEFFICIENT: 90 PCF
2. ACTIVE COEFFICIENT: 70 PCF
3. PASSIVE PRESSURE: 210 PCF
E. SLAB, MAT, TANK, AND SHALLOW FOUNDATION PARAMETERS:
1. MODULUS OF SUBGRADE REACTION: 100 PCI
2. ALLOWABLE NET BEARING CAPACITY: 2,500 PSF
3. FROST DEPTH: 24" MINIMUM
F. DEEP FOUNDATIONS (DRILLED CAST IN PLACE CONCRETE CAISSONS)
1. ALLOWABLE END BEARING CAPACITIES MEASURED FROM MSL FROM 1278.0 FT (IN CONTACT WITH SHALE ROCK):
a. 14' - 19' DEEP: 33,000 PSF
b. 19' - 29' DEEP: 36,000 PSF
c. 29' DEEP OR GREATER: 43,000 PSF
2. ALLOWABLE SKIN FRICTION CAPACITIES MEASURED FROM MSL FROM 1278.0 FT (IN CONTACT WITH SHALE ROCK):
a. 14' - 19' DEEP: 1,000 PSF
b. 19' - 29' DEEP: 1,000 PSF
c. 29' DEEP OR GREATER: 1,000 PSF
d. UPLIFT RESISTANCE: CAISSON WEIGHT PLUS SKIN FRICTION VALUES ABOVE.
G. MINIMUM STABILITY FACTORS OF SAFETY
1. OVERTURNING: 1.5
2. UPLIFT: 1.5
3. SLIDING: 1.5
3. FORMWORK
a. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN, ENGINEERING, STRUCTURAL
ADEQUACY, AND CONSTRUCTION OF ALL CONCRETE FORMWORK IN ACCORDANCE
WITH THE CONTRACT SPECIFICATIONS.
b. COORDINATE ALL CONCRETE WORK WITH THE PLACEMENT OF PIPING, INSERTS, FLOOR DRAINS, AND OTHER EMBEDDED ITEMS INDICATED ON THE CONTRACT
DRAWINGS OR IN THE CONTRACT SPECIFICATIONS.
c. ALL NEW OR EXISTING PIPING OR UTILITIES PASSING THROUGH NEW CONCRETE
SHALL BE SLEEVED 1/2" CLEAR ALL AROUND, UNLESS NOTED OTHERWISE.
(SEE OTHER DISCIPLINE DRAWINGS FOR SLEEVE DETAILS. CONTRACTOR SHALL
PROVIDE MEASURES TO ENSURE THAT SLEEVES REMAIN FREE OF DEBRIS AND WATER
DURING CONSTRUCTION.)
d. PROVIDE 3/4" CHAMFER STRIPS ON ALL EDGES OF EXPOSED CONCRETE, UNLESS
NOTED OTHERWISE.
e. VOID FORMS SHALL BE 4" DEEP.
f. ALL FORMED CONCRETE SURFACES WITH THE EXCEPTION OF DRILLED CAISSONS SHALL
USE FORMWORK. EARTH FORMED EXCAVATED SURFACES ARE PROHIBITED.
4. REINFORCING STEEL
a. BARS: ASTM A615 GRADE 60.
b. WELDED WIRE FABRIC: ASTM A1064.
c. ALL CONCRETE SHALL BE REINFORCED UNLESS SPECIFICALLY MARKED "NOT
REINFORCED" OR "UNREINFORCED".
d. CONTRACTOR SHALL DETAIL AND PLACE ALL REINFORCEMENT IN ACCORDANCE WITH
ACI SP-66, ACI 301, ACI 318, AND CRSI MANUAL OF STANDARD PRACTICE.
e. MINIMUM CONCRETE CLEAR COVER OVER REINFORCEMENT SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE:
(1) CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3".
(2) CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THROUGH #11 BARS - 2"; #5
AND SMALLER BARS, WELDED WIRE FABRIC - 1 1/2".
(3) CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:
SLABS AND WALLS - 3/4"; BEAMS AND COLUMNS, PRIMARY REINFORCEMENT, TIES,
STIRRUPS, SPIRALS - 1 1/2".
f. EPOXY GROUT: CONFORM TO ASTM C881, TYPE IV, GRADE 3, EXCEPT GEL TIMES.
PROVIDE MINIMUM EMBEDMENT LENGTH REQUIRED TO DEVELOP ULTIMATE STRENGTH
OF BAR.
g. PROVIDE ADDITIONAL REINFORCEMENT AT ALL OPENINGS AND CORNER BARS AT ALL
INTERSECTING GRADE BEAMS, WALLS, AND CURBS IN ACCORDANCE WITH THE STANDARD
DETAILS ON DRAWING S-008M AND S-009M, UNLESS NOTED OTHERWISE.
3. SPECIAL INSPECTIONS: SEE STATEMENT OF SPECIAL INSPECTIONS ON DRAWING S-003M.
4. DESIGN LOADS
A. RISK CATEGORY: IV PER UFC 3-301-01 (BUILDING AND TANKS).
B. ESTIMATED COLLATERAL LOADS (FIRE PROTECTION PIPING, LIGHTING AND
ELECTRICAL, MECHANICAL): 45 PSF
C. LIVE LOADS
1. FLOOR LIVE LOAD
a. UNIFORM: 250 PSF.
2. ROOF LIVE LOAD
a. UNIFORM: 20 PSF NONREDUCIBLE.
b. 500 LB CONCENTRATED, CONCURRENT WITH UNIFORM LOAD
D. EQUIPMENT LOADS
1. AS INDICATED FOR EQUIPMENT WEIGHING IN EXCESS OF 250 LBS. FRAMING AND
FOUNDATIONS ARE DESIGNED FOR EQUIPMENT WHICH SATISFIES THE CONTRACT
SPECIFICATIONS.
2. IF EQUIPMENT FURNISHED IS HEAVIER THAN THE WEIGHTS INDICATED, OR
REQUIRES STRUCTURAL CHANGES FOR ANY OTHER REASON, CONTRACTOR SHALL
PROVIDE ENGINEERING DESIGN CALCULATIONS AND ADDITIONAL STRUCTURAL
WORK NECESSARY TO SUPPORT ALL LOADS IN ACCORDANCE WITH THE DESIGN
STANDARDS SPECIFIED ABOVE, AT NO ADDITIONAL COST TO THE GOVERNMENT
AND WITH NO INCREASE IN CONTRACT TIME.
6. MATERIALS: SEE THE CONTRACT SPECIFICATIONS FOR COMPLETE REQUIREMENTS
AND COMPLY WITH ALL APPLICABLE OSHA REGULATIONS
A. REINFORCED CONCRETE: SECTIONS: 03 11 13.00 10, 03 20 00.00 10, 03 30 00.00 10
1. REINFORCED CONCRETE SHALL BE PREPARED AND PLACED IN
ACCORDANCE WITH ACI MANUAL OF CONCRETE PRACTICE.
2. CONCRETE
a. UNLESS NOTED OTHERWISE: MINIMUM 28-DAY COMPRESSIVE STRENGTH f'c = 4500 PSI, NORMAL WEIGHT.
b. SLABS ON GRADE: MINIMUM 28-DAY COMPRESSIVE STRENGTH = 4500 PSI.
GENERAL NOTES: APPLICABLE TO ALL STRUCTURAL SHEETS
C. STRUCTURAL AND MISCELLANEOUS STEEL: SECTIONS 05 05 23, 05 12 00
1. STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN
ACCORDANCE WITH AISC STEEL CONSTRUCTION MANUAL, 14th EDITION.
2. TEMPORARY ERECTION BRACING SHALL BE DESIGNED AND PROVIDED BY THE CONTRACTOR
AS REQUIRED AND SHALL NOT BE REMOVED UNTIL ALL PERMANENT LATERAL-LOAD-RESISTING
ELEMENTS AND CONNECTIONS ARE COMPLETELY INSTALLED.
3. WIDE FLANGE SHAPES AND TEES: ASTM A992, Fy = 50 KSI.
4. OTHER SHAPES, PLATES, AND THREADED RODS
a. ASTM A36, Fy = 36 KSI, UNLESS NOTED OTHERWISE.
b. ASTM A572 GRADE 50, Fy = 50 KSI, WHERE INDICATED AS "(50)".
5. SQUARE AND RECTANGULAR HOLLOW STRUCTURAL SECTIONS: ASTM A500 GRADE
B, Fy = 46 KSI.
6. ROUND HOLLOW STRUCTURAL SECTIONS: ASTM A500 GRADE B, Fy = 42 KSI.
7. PIPE: ASTM A53 TYPE E OR S, GRADE B, Fy = 35 KSI.
8. BOLTS
a. 3/4" DIAMETER ASTM A325, UNLESS NOTED OTHERWISE.
b. FRAMING CONNECTIONS: PRETENSIONED IN STD HOLES, TYP, UNLESS NOTED OTHERWISE.
c. BRACING CONNECTIONS: SLIP CRITICAL IN STD HOLES, UNLESS
NOTED OTHERWISE.
d. SLIP-CRITICAL JOINTS (A325 OR A490 BOLTS) SHALL HAVE CLASS A FAYING
SURFACES WITH SLIP CHECKED AT THE FACTORED LOAD LEVEL.
e. ON ONE SIDE OF EACH DOUBLE CONNECTION OF BEAMS TO A COLUMN WEB OR A
GIRDER WEB DIRECTLY OVER A COLUMN, PROVIDE A TEMPORARY SEAT ANGLE
ATTACHED TO COLUMN OR GIRDER WEB AND TO BOTTOM FLANGE OF BEAM. MINIMUM
SEAT CONNECTION SHALL BE L4x3x3/8 LLH WITH TWO 3/4" DIAMETER A307 OR A325-ST
BOLTS EACH LEG. SINGLE AND DOUBLE STAGGERED CONNECTIONS ARE PROHIBITED
WITHOUT THE EXPLICIT PRIOR APPROVAL IN WRITING OF THE STRUCTURAL ENGINEER OF
RECORD.
9. WELDING: IN ACCORDANCE WITH AWS D1.1 USING E70 ELECTRODE WITH LOW HYDROGEN.
10. ALL DOUBLE ANGLE MEMBERS SHALL HAVE SPACER PLATES TO COMPLY WITH AISC
PARAGRAPH E6.
a. THICKNESS: TO MATCH END GUSSET PLATES.
b. MINIMUM ATTACHMENT: CONNECT TO HEEL AND TOE OF EACH ANGLE USING 3/16" x 1"
LONG FILLET WELDS.
11. HEADED STUDS
a. COLD-FINISHED STEEL CONFORMING TO ASTM A108, GRADE 1015 OR 1020.
b. ALL STUDS LOCATED SO AS TO OBSTRUCT WALKING SURFACES OF BEAMS
SHALL BE FIELD INSTALLED.
12. ANCHOR BOLTS
a. ASTM F1554 GRADE 55 MEETING S1 REQUIREMENTS, UNLESS NOTED OTHERWISE.
b. LOCATE ANCHOR BOLTS ACCURATELY, SET WITH TEMPLATES, AND SECURELY HOLD IN
POSITION WHILE PLACING CONCRETE.
CONCRETE. PROTECT IN-PLACE ANCHOR BOLTS FROM CONSTRUCTION ACTIVITY.
c. THE FOLLOWING ARE PROHIBITED WITHOUT THE EXPLICIT PRIOR APPROVAL IN WRITING
OF THE STRUCTURAL ENGINEER OF RECORD:
(1) INSERTING ANCHOR BOLTS INTO FRESH OR PARTIALLY HARDENED CONCRETE.
(2) SUBSTITUTING POST-INSTALLED ANCHORS WHERE EMBEDDED ANCHOR BOLTS
ARE INDICATED.
(3) REPAIRING, REPLACING, OR MODIFYING INSTALLED ANCHOR BOLTS.
13. POST-INSTALLED ANCHORS
a. CONCRETE ANCHORS: CARBON STEEL MANUALLY EXPANDED WEDGE
TYPE, UNLESS NOTED OTHERWISE.
b. ADHESIVE ANCHORS: ASTM A36 CARBON STEEL THREADED ROD WITH VINYL URETHANE
METHACRYLATE RESIN ADHESIVE, UNLESS NOTED OTHERWISE.
c. MASONRY ANCHORS: ASTM A36 CARBON STEEL THREADED ROD WITH CYLINDRICAL
WIRE MESH SCREEN TUBE AND INJECTABLE HYBRID ADHESIVE, UNLESS NOTED OTHERWISE.
14. GROUT: CEMENTITIOUS NONSHRINK.
6. MATERIALS: (CONT)
5. JOINTS
a. LOCATE ALL CONSTRUCTION, CONTRACTION, ISOLATION, EXPANSION, AND OTHER JOINTS
AS INDICATED OR SPECIFIED, OR OTHERWISE APPROVED BY THE CONTRACTING OFFICER.
b. SURFACES OF ALL HORIZONTAL AND VERTICAL CONSTRUCTION JOINTS SHALL BE CLEANED
OF LAITANCE AND SHALL EXPOSE CLEAN COARSE AGGREGATE SOLIDLY EMBEDDED IN
MORTAR MIX. JUST PRIOR TO DEPOSITING CONCRETE, SURFACE OF CONSTRUCTION JOINT
SHALL BE THOROUGHLY CLEANED AND WETTED.
c. THESE PROVISIONS SHALL ALSO APPLY WHEN NEW CONCRETE IS PLACED AGAINST EXISTING
CONCRETE. IN ADDITION, EXISTING CONCRETE SURFACE SHALL BE ADEQUATELY PREPARED
BY APPLICATION OF A BONDING AGENT.
d. PROVIDE WATERSTOPS AT CONCRETE JOINTS WHERE INDICATED ON THE CONTRACT DRAWINGS.
B. REINFORCED MASONRY: SECTION 04 20 00
1. SEE S-010M FOR REINFORCED MASONRY NOTES AND DETAILS.
D. STEEL DECK: SECTIONS 05 30 00
1. STEEL DECK, ATTACHMENTS, AND ACCESSORIES SHALL BE DESIGNED, FABRICATED,
AND INSTALLED IN ACCORDANCE WITH SDI MANUALS AND AISI COLD-FORMED STEEL
DESIGN MANUAL.
2. ROOF DECK
a. 1 1/2", 18 GAGE, WIDE RIB WITH
Fy = 33 KSI, Imin = 0.289 IN^4/FT, Smin = 0.318 IN^3/FT, GALVANIZED G90
3. ALL STEEL DECK AND DECK ATTACHMENTS SHALL BE CAPABLE OF RESISTING THE WIND
UPLIFT LOADS INDICATED ON THE CONTRACT DRAWINGS AND AN ALLOWABLE
DIAPHRAGM SHEAR STRENGTH OF 761 PLF.
4. ALL STEEL DECK SHALL CROSS A MINIMUM OF TWO SPANS. MINIMUM LENGTH OF END
LAPS AND BEARING AT ALL SUPPORTS SHALL BE 2".
5. ALL STEEL DECK SHALL BE SUPPORTED AT EDGES OF OPENINGS AND AROUND
COLUMNS. ADDITIONAL SUPPORT STEEL SHALL BE PROVIDED BY CONTRACTOR AS
REQUIRED AND FABRICATED SO THAT DECK RUNS CONTINOUSLY OVER MINOR
OPENINGS, WHICH SHALL NOT BE CUT UNTIL NEEDED BY OTHER TRADES.
6. MINIMUM STEEL DECK ATTACHMENT SHALL BE AS FOLLOWS:
a. DECK SHALL BE FASTENED AT EACH END AND AT INTERMEDIATE SUPPORTS
BY 3/4" DIAMETER PUDDLE WELDS, 36/5 PATTERN.
b. SIDE LAP CONNECTIONS SHALL BE MADE AT SEAMS USING 1 1/2" ARC SEAM
WELDS, 4 PER SPAN.
c. CONNECTIONS ALONG SIDE BOUNDARIES, RIDGE PLATES, AND ROOF SUB
FRAMING SHALL BE MADE AT 12" ON CENTER MAXIMUM.
d. PNEUMATIC FASTENERS AND/OR SCREWS SHALL NOT BE SUBSTITUTED WHERE
WELDS ARE SPECIFIED, BUT MAY BE USED IN TEMPORARY ATTACHMENT OF
STEEL DECK.
E. COLD-FORMED STEEL FRAMING: SECTION 05 40 00
1. COLD-FORMED STEEL FRAMING SHALL BE DESIGNED, FABRICATED, AND ERECTED IN
ACCORDANCE WITH AISI COLD-FORMED STEEL DESIGN MANUAL AND SSMA PUBLICATIONS
AS APPLICABLE.
2. SHAPE DESIGNATIONS
a. STUDS, TRACK, CHANNELS, AND FURRING CHANNELS: PER SSMA
PRODUCT TECHNICAL INFORMATION, INDICATING MEMBER DEPTH, STYLE,
FLANGE WIDTH, AND MATERIAL THICKNESS.
3. FRAMING MEMBERS
a. ASTM A1003 GRADE 33, Fy = 33 KSI, UNLESS NOTED OTHERWISE.
b. ASTM A653 GRADE 50, FY = 50 KSI, UNLESS NOTED OTHERWISE.
4. FINISH
a. STEEL CONFORMING TO ASTM A1003/A653: HOT-DIP GALVANIZE TO PROVIDE A COATING
CLASS OF G90.
5. MECHANICAL FASTENERS: CORROSION-RESISTANT-COATED, SELF-DRILLING, SELF-
THREADING STEEL DRILL SCREWS WITH LOW PROFILE HEADS BENEATH SHEATHING AND
MANUFACTURER'S STANDARD HEADS ELSEWHERE.
6. BOLTS: ASTM A307.
7. WELDING: IN ACCORDANCE WITH AWS D1.1 OR D1.3, AS APPLICABLE.
F. STEEL BAR GRATING: SECTION 05 50 13
1. STEEL BAR GRATING SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH
NAAMM MANUALS.
2. MATERIAL: ASTM A569.
3. CONSTRUCTION: WELDED, HOT DIP GALVANIZED, WELDED ANCHORS.
4. W-19-4 GRATING, (1" X 3/16" BEARING BARS)
5. CROSS BARS: AT 4" CENTERS.
6. SURFACE: PLAIN, BAND ALL EDGES.
7. FABRICATE GRATING IN SECTIONS NOT GREATER THAN 5 FT WIDE, UNO.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/1
9/
2:
:2
PM
/2
2/
S-001M
G
EN
ER
AL
N O
TE
S
P.
M
AN
IS
R .Y
O U
N
KE
R C
. M C
G
EE
W W
YK
0 5
S-
1M .D
W G
P.
M
AN
IS
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
CALLOUT IDENTIFICATION
SECTION, DETAIL, AND ELEVATION SYMBOL IDENTIFIERS:
DRAWING SEQUENCE NUMBER INDICATES
WHERE TITLE IS LOCATED (MAY NOT BE
PRESENT IF CALLOUT AND TITLE ARE ON THE
SAME DRAWING)
ONE OR TWO CHARACTER DISCIPLINE
DESIGNATOR (MAY NOT BE PRESENT IF
CALLOUT AND TITLE ARE ON DRAWINGS
WITHIN THE SAME DISCIPLINE)
PLAN
NORTH
BUILDING SECTION CALLOUT EXAMPLE:
DETAIL CALLOUT EXAMPLE:
TITLE EXAMPLE:
WALL SECTION CALLOUT EXAMPLE:
N
A1A1
A1
LETTER AND NUMBER
INDICATES SECTION
DRAWING NUMBER
WHERE SECTION IS
DRAWN
LETTER AND NUMBER
INDICATES SECTION
DRAWING NUMBER
WHERE SECTION IS
DRAWN
A1
LETTER AND NUMBER DESIGNATOR .
LETTER IDENTIFIES THE SHEET ROW
LOCATION AND NUMBER IDENTIFIES THE
SHEET COLUMN LOCATION OF DETAIL
A1
LETTER AND NUMBER
INDICATES DETAIL
DRAWING NUMBER
WHERE DETAIL IS
DRAWN
0 1/2' 1' 2'
S-100 SIM
S-100 SIMS-100 SIM
S-100
SIM
S-100
SIM
SLAB DEPRESSION
LOCATION OF VERTICAL BRACING
AA - ALUMINUM ASSOCIATION
AB - ANCHOR BOLT
ABT - ABOUT
ACI - AMERICAN CONCRETE
INSTITUTE
ADH - ADHESIVE
AGGR - AGGREGATE
AHR - ANCHOR
AISI - AMERICAN IRON AND
STEEL INSTITUTE
AISC - AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AL - ALUMINUM
ALTN - ALTERNATE
ANSI - AMERICAN NATIONAL
STANDARDS INSTITUTE
APPROX - APPROXIMATE
ARCH - ARCHITECT
ASTM - AMERICAN SOCIETY FOR
TESTING OF MATERIALS
AWS - AMERICAN WELDING
SOCIETY
BC - BOLT CIRCLE
BETW - BETWEEN
BLDG - BUILDING
BM - BEAM
BO - BOTTOM OF
BOS OR
B/S - BOTTOM OF STEEL
BTM - BOTTOM
B/C - BASE OF CAISSON
BRG - BEARING
BRKT - BRACKET
CAP - CAPACITY
C/C - CENTER TO CENTER
CL - CENTER LINE
CF - CUBIC FEET
CHKR - CHECKER
CIR - CIRCLE
CJ - CONSTRUCTION JOINT
CLR - CLEAR
CLJ - CONTROL JOINT
CMU - CONCRETE MASONRY UNIT
CO - CONCRETE OPENING
COMP - COMPRESSION
CONC - CONCRETE
CONT - CONTINUOUS
CONTR - CONTRACT
COL - COLUMN
CONN - CONNECTION
COTR - CONTRACTING OFFICER
COR - CORNER
COORD - COORDINATE
CRSI - CONCRETE REINFORCING
STEEL INSTITUTE
CTJ - CONTRACTION JOINT
CTR - CENTER
CTRD - CENTERED
CY - CUBIC YARD
DBL - DOUBLE
DET - DETAIL
DIAG - DIAGONAL
DIA - DIAMETER
DIM - DIMENSION
DK - DECKING
DL - DEAD LOAD
DN - DOWN
DWL - DOWEL
DWG - DRAWING
E - EAST
EA - EACH
EOD - EDGE OF DECK
ED - EQUIPMENT DRAIN
EF - EACH FACE
EJ - EXPANSION JOINT
EL - ELEVATION
ELEC - ELECTRICAL
ELEV - ELEVATOR
EMBED - EMBEDMENT
EQ - EQUAL
EQUIV - EQUIVALENT
EQ SPA - EQUALLY SPACED
EQPT - EQUIPMENT
EXIST - EXISTING
EXP - EXPANSION
EXT - EXTERIOR
EW - EACH WAY
FAB - FABRICATE
FD - FLOOR DRAIN
FDN - FOUNDATION
FTG - FOOTING
FF - FAR FACE
FL - FLOOR
FLG - FLANGE
FNSH - FINISH
FS - FAR SIDE
FT - FEET
FUT - FUTURE
GA - GAGE
GALV - GALVANIZE
GB - GRADE BEAM
GND - GROUND
GR - GRADE
GRTG - GRATING
H - SLAB THICKNESS
HEF - HORIZONTAL EACH
FACE
HEX - HEXAGON
HG - HIGH
HK - HOOK
HR - HANDRAIL
HPT - HIGH POINT
HORIZ - HORIZONTAL
HS - HIGH STRENGTH
IBC - INTERNATIONAL
BUILDING CODE
ID - INSIDE DIAMETER
IF - INSIDE FACE
IJ - ISOLATION JOINT
IN - INCHES
INTR - INTERIOR
INVT - INVERT
IR - INSIDE RADIUS
JT - JOINT
KB - KNEE BRACE
KPL - KICK PLATE
KSI - KIPS PER
SQUARE INCH
L - ANGLE
LAD - LADDER
LB - POUND
LD - DEVELOPMENT LENGTH
LG - LONG
LL - LIVE LOAD
LLBB - LONG LEG BACK TO BACK
LLH - LONG LEG HORIZONTAL
LLO - LONG LEG OUTSTANDING
LLV - LONG LEG VERTICAL
LONG - LONGITUDINAL
LPT - LOW POINT
LNTL - LINTEL
LS - LAP SPLICE
MATL - MATERIAL
MAX - MAXIMUM
MC - MOMENT CONNECTION
MECH - MECHANICAL
MEZZ - MEZZANINE
MFR OR
MFG - MANUFACTURER
MH - MANHOLE
MIN - MINIMUM
MISC - MISCELLANEOUS
MK - MARK
MO - MASONRY OPENING
N - NORTH
NA - NOT APPLICABLE
NE - NORTHEAST
NF - NEAR FACE
NOM - NOMINAL
NW - NORTHWEST
NIC - NOT IN CONTRACT
NTS - NOT TO SCALE
NO - NUMBER
NS - NEAR SIDE
OC - ON CENTER
OD - OUTSIDE DIAMETER
OF - OUTSIDE FACE
OH - OVERHEAD
OPNG - OPENING
OPP - OPPOSITE
OSHA - OCCUPATIONAL SAFETY
AND HEALTH ADMINISTRATION
OZ - OUNCE
PCF - POUNDS PER CUBIC FOOT
PED - PEDESTAL
PEN - PENETRATE
PEMP - PRE-ENGINEERED METAL
BUILDING
PERP - PERPINDICULAR
PJNT - PROJECTION
PL - PLATE
PLC - PLACES
PREFAB - PREFABRICATED
PS - PIPE SUPPORT
PSF - POUNDS PER SQUARE FOOT
PSI - POUNDS PER SQUARE INCH
PT - PRETENSIONED
PVC - POLYVINYL CHLORIDE
R - RISER
RAD - RADIUS
RD - ROOF DRAIN
REF - REFERENCE
REINF - REINFORCE
REQD - REQUIRED
REV - REVISION
RM - ROOM
S - SOUTH
SB - SHEAR BAR
SCHED - SCHEDULE
SE - SOUTHEAST
SECT - SECTION
SH - SHEET
SIM - SIMILAR
SF - SWAY FRAME
SLO - SHORT LEG OUTSTANDING
SLP - SLOPE
SLV - SLEEVE
SP - SPACE
SPEC - SPECIFICATION
SQ - SQUARE
SST - STAINLESS STEEL
STD - STANDARD
STL - STEEL
STIF - STIFFENER
STIR - STIRRUP
STR - STRAIGHT
STRL - STRUCTURAL
STRUC - STRUCTURE
SW - SOUTHWEST
SYMM - SYMMETRICAL
T - TON
TEMP - TEMPORARY
THK - THICK
THRU - THROUGH
THD - THREAD
T/ - TOP OF
TOB - TOP OF BOLT
T/C OR
TOC - TOP OF CONCRETE
TOG - TOP OF GRATING
T/STL OR
TOS - TOP OF STEEL
T/C - TOP OF CAISSON
T&B - TOP AND BOTTOM
TRANS - TRANSVERSE
TRD - TREAD
TYP - TYPICAL
UNO - UNLESS NOTED
OTHERWISE
UT -ULTRASONICALLY TESTED
VAR - VARIES
VERT - VERTICAL
VEF - VERTICAL EACH FACE
VRC - VERTICAL RECIPROCATING CONVEYOR
W - WEST
WD - WIDE
W/ - WITH
W/O - WITHOUT
WP - WORK POINT
WS - WATERSTOP
WT - WEIGHT
WWF - WELDED WIRE
FABRIC
WDT - WIDTH
XX - LOCATION OF BRACING
@ - AT
& - AND
# - POUNDS OR NUMBER
% - PERCENT
ABBREVIATIONS:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/1
9/
2:
:2
PM
/2
2/
S-002M
AB
BR
EV
IA
TI
O
N S
AN
D
K
EY
P.
M
AN
IS
R .Y
O U
N
KE
R C
. M C
G
EE
W W
YK
0 5
S-
2M .D
W G
P.
M
AN
IS
SCALE: 1" = 1'-0"A1 VIEW TITLE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
IBC 2012 TABLE 1705.2.2 REQUIRED VERIFICATION AND INSPECTION
OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARDª
1. MATERIAL VERIFICATION OF COLD-FORMED STEEL DECK:
APPLICABLE ASTM
MATERIAL STANDARDS
2. INSPECTION OF WELDING:
AWS D1.4
ACI 318: SECTION 3.5.2
— X
X—
X—
a. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS.
b. MANUFACTURER'S CERTIFIED TEST REPORTS.
a. COLD-FORMED STEEL DECK:
AWS D1.3X—1) FLOOR AND ROOF DECK WELDS.
b. REINFORCING STEEL:
X—1) VERIFICATION OF WELDABILITY OF REINFORCING STEEL
OTHER THAN ASTM A 706.
—X2) REINFORCING STEEL RESISTING FLEXURAL AND AXIAL
FORCES IN INTERMEDIATE AND SPECIAL MOMENT FRAMES,
AND BOUNDARY ELEMENTS OF SPECIAL STRUCTURAL
WALLS OF CONCRETE AND SHEAR REINFORCEMENT.
3) SHEAR REINFORCEMENT
X—4) OTHER REINFORCING STEEL.
IBC 2012 TABLE 1705.3 REQUIRED VERIFICATION
AND INSPECTION OF CONCRETE CONSTRUCTION
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARDª IBC REFERENCE
1. INSPECTION OF REINFORCING STEEL. X ACI 318: 3.5, 7.1-7.7 1910.4
2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE
WITH TABLE 1705.2.2, ITEM 2b.
AWS D1.4 ACI 318: 3.5.2 —
3. INSPECTION OF ANCHORS CAST IN CONCRETE WHERE
ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE
STRENGTH DESIGN IS USED.
1908.5, 1909.1
4. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED
CONCRETE MEMBERS.
X ACI 318: 3.8.6, 8.1.3, 21.2.8 1909.1
5. VERIFYING USE OF REQUIRED DESIGN MIX. ACI 318: CH. 4, 5.2-5.4
6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR
CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
X
ASTM C 172
ASTM C 31
ACI 318: 5.6, 5.8
1910.10
7. INSPECTION OF CONCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
__ ACI 318: 5.9, 5.10 1910.6,
1910.7, 1910.8
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
a. APPLICATION OF PRESTRESSING FORCES. X ACI 318: 18.20
9. INSPECTION OF PRECAST CONCRETE :
10.ERECTION OF PRECAST CONCRETE MEMBERS. X ACI 318: CH. 16
11.VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO
STRESSING OF TENDONS IN POST-TENSIONED CONCRETE AND
PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND
STRUCTURAL SLABS. X ACI 318: 6.2
X
X
ACI 318: 8.1.3, 21.2.8
1904.2, 1910.2, 1910.3
X— ACI 318: 5.11- 5.13 1910.9
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.
X ACI 318: 6.1.1—
X—
FOR SI: 1 INCH = 25.4 MM
a. WHERE APPLICABLE, SEE ALSO SECTION 1705.11, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE.
b. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN
APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2 OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE
APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK.
c. WHEN DIRECTED BY THE CONTRACT DOCUMENTS TO PROVIDE POST-INSTALLED ANCHORAGES THE FOLLOWING GUIDELINES SHALL BE
FOLLOWED:
1. A REPRESENTATIVE OF THE ANCHOR MANUFACTURER OR PROJECT SPECIAL INSPECTOR SHALL BE ON SITE TO OVERSEE THE
INSTALLATION OF THE FIRST FOUR ANCHORS FOR EACH TYPE OF ANCHOR INSTALLED. THIS MEASURE SHALL BE TAKEN FOR EACH INSTALLER OF THE ANCHORS. THIS SERVICE IS TYPICALLY PROVIDED FREE BY THE LOCAL ANCHOR REPRESENTATIVE.
2. THE FIRST FOUR ANCHORS SHALL BE TENSION TESTED ONCE INSTALLATION IS COMPLETE FOR 200% OF THE SERVICE LEVEL LOAD
CAPACITY AS SPECIFIED BY THE MANUFACTURER.
IBC 2012 TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION TASK
CONTINUOUS DURING
TASK LISTED
PERIODICALLY DURING
TASK LISTED
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. — X
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. — X
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. — X
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL. X —
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN
PREPARED PROPERLY. — X
IBC 2012 TABLE 1705.8 REQUIRED VERIFICATION AND
INSPECTION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
VERIFICATION AND INSPECTION TASK
1. OBSERVE DRILLING OPERATIONS AND MAINTAIN COMPLETE AND ACCURATE RECORDS FOR EACH ELEMENT. X
2. VERIFY PLACEMENT LOCATIONS AND PLUMBNESS, CONFIRM ELEMENT DIAMETERS, BELL DIAMETERS (IF APPLICABLE), LENGTHS, EMBEDMENT INTO BEDROCK (IF APPLICABLE) AND ADEQUATE END-BEARING
STRATA CAPACITY. RECORD CONCRETE OR GROUT VOLUMES.
X —
3. FOR CONCRETE ELEMENTS, PERFORM ADDITIONAL INSPECTIONS IN ACCORDANCE WITH SECTION 1705.8 ——
CONTINUOUS DURING
TASK LISTED
PERIODICALLY DURING
TASK LISTED
ACI 530-11 TABLE 1.19.2 - LEVEL B QUALITY
ASSURANCE - MASONRY
CONTINUOUS PERIODIC
ART. 1.5X—1. VERIFY COMPLIANCE WITH THE APPROVED SUBMITTALS
MINIMUM TESTS
MINIMUM INSPECTION
VERIFICATION OF SLUMP FLOW AND VISUAL STABILITY INDEX (VSI) AS DELIVERED TO THE PROJECT SITE IN ACCORDANCE WITH SPECIFICATION ARTICLE 1.5 B.1b.3 FOR SELF-CONSOLIDATING GROUT
VERIFICATION OF f' m IN ACCORDANCE WITH SPECIFICATION ARTICLE 1.4 B PRIOR TO
CONSTRUCTION, EXCEPT WHERE SPECIFICALLY EXEMPTED BY THIS CODE
INSPECTION TASK
FREQUENCY (a) REFERENCE FOR CRITERIA
TMS 402/
ACI 530/
ASCE 5
TMS 602/
ACI 530.1/
ASCE 6
2. AS MASONRY CONSTRUCTION BEGINS, VERIFY THAT THE
FOLLOWING ARE IN COMPLIANCE:
ART. 2.1, 2.6 Aa. PROPORTIONS OF SITE-PREPARED MORTAR X—
ART. 3.3 Bb. CONSTRUCTION OF MORTAR JOINTS X—
c. LOCATION OF REINFORCEMENT, CONNECTORS X— ART. 3.4,
3.6 A
3. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN
COMPLIANCE:
a. GROUT SPACE X—
b. GRADE, TYPE, AND SIZE OF REINFORCEMENT AND ANCHOR
BOLTS X—
c. PLACEMENT OF REINFORCEMENT, CONNECTORS X—
d. PROPORTIONS OF SITE-PREPARED GROUT X— ART. 2.6 B,
2.4 G.1.b
ART. 3.3 Be. CONSTRUCTION OF MORTAR JOINTS X—
ART. 3.2 D,
3.2 F
SEC. 1.16
SEC. 1.16
ART. 2.4, 3.4
ART. 3.2 E,
3.4, 3.6 A
4. VERIFY DURING CONSTRUCTION:
a. SIZE AND LOCATION OF STRUCTURAL ELEMENTS X—
b. TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING OTHER
DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL
MEMBERS, FRAMES, OR OTHER CONSTRUCTION
X—
c. PREPARATION, CONSTRUCTION, AND PROTECTION OF
MASONRY DURING COLD WEATHER (TEMPERATURE BELOW
40°F (4.4°C)) OR HOT WEATHER (TEMPERATURE ABOVE
90°F (32.2°C))
X—
d. PLACEMENT OF GROUT X— ART. 2.6 B,
2.4 G.1.b
ART. 3.2 D,
3.2 F
SEC. 1.16
SEC. 1.16
ART. 2.4, 3.4
ART. 3.2 E,
3.4, 3.6 A
3. OBSERVE PERPARATION OF GROUT SPECIMENS, MORTAR
SPECIMENS, AND/OR PRISMS X— ART. 1.4
B32.a.3,
1.4 B.2.b.3,
1.4 B.2.c.3,
1.4 B.3,
1.4 B.4
(a) FREQUENCY REFERS TO THE FREQUENCY OF INSPECTION, WHICH MAY BE CONTINUOUS DURING THE TASK LISTED OR
PERIODICALLY DURING THE LISTED TASK, AS DEFINED IN THE TABLE.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/1
9/
2:
:3
PM
/2
2/
S-003M
ST
AT
EM
EN
T O
F
SP
EC
IA
L
IN
SP
EC
TI
O
N S
P.
M
AN
IS
R .Y
O U
N
KE
R C
. M C
G
EE
W W
YK
0 5
S-
3M .D
W G
P.
M
AN
IS
1. STATEMENT OF SPECIAL INSPECTIONS
A. THIS "STATEMENT OF SPECIAL INSPECTIONS" HAS BEEN PREPARED IN ACCORDANCE WITH IBC 2012, SECTION 1704.
B. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED THIRD-PARTY QUALITY ASSURANCE AGENCIES TO PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
C. EACH SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE CONTRACTING OFFICER'S REPRESENTATIVE, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION.
D. SPECIAL INSPECTION AGENCY SHALL SUBMIT INSPECTION REPORTS DURING CONSTRUCTION FOR VERIFICATION, INCLUDING FINAL REPORTS IN ACCORDANCE WITH IBC 2012, SECTION 1704.1.2.
E. SPECIAL INSPECTOR SHALL USE THE LATEST ISSUE OF THE STRUCTURAL DRAWINGS FOR ALL INSPECTIONS. SHOP FABRICATION DRAWINGS SHALL NOT BE USED FOR SUCH PURPOSES.
F. THE FOLLOWING TABLES IDENTIFY THE MATERIALS, SYSTEMS, AND COMPONENTS FOR WHICH SPECIAL INSPECTION IS REQUIRED.
2. TESTING REQUIREMENTS
A. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED THIRD-PARTY TESTING AGENCIES TO PROVIDE STRUCTURAL TESTING DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
B. TESTING AGENCY SHALL SUBMIT TEST RESULTS DURING CONSTRUCTION FOR VERIFICATION INCLUDING A FINAL REPORT IN ACCORDANCE WITH IBC 2012, 1704.2.4.
C. THE TABLES BELOW IDENTIFY THE STRUCTURAL TESTS REQUIRED FOR THIS PROJECT.
3. STRUCTURAL OBSERVATIONS
A. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED THIRD-PARTY REGISTERED DESIGN PROFESSIONALS TO PROVIDE STRUCTURAL OBSERVATIONS DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
B. EACH STRUCTURAL OBSERVER SHALL SUBMIT WRITTEN STATEMENTS IDENTIFYING FREQUENCY AND EXTENT OF STRUCTURAL OBSERVATIONS AND ANY REPORTED DEFICIENCIES WHICH, TO THE BEST OF THE STRUCTURAL OBSERVERS KNOWLEDGE, HAVE NOT BEEN RESOLVED.
NOTES:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
AISC 360-10 TABLE N5.4-1
INSPECTION TASKS PRIOR TO WELDING
INSPECTION TASKS PRIOR TO WELDING QC QA
WELDING PROCEDURE SPECIFICATION (WPSs) AVAILABLE P
MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
MATERIAL IDENTIFICATION (TYPE/GRADE)
WELDER IDENTIFICATION SYSTEM (1)
FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)
• JOINT PREPARATION
• DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
• BACKING TYPE AND FIT (IF APPLICABLE)
CONFIGURATION AND FINISH OF ACCESS HOLES
FIT-UP OF FILLET WELDS
(1) THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS TYP.
CHECK WELDING EQUIPMENT
P
• DIMENSIONS (ALIGNMENT, GAPS AT ROOT)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
PP
OO
OO
OO
OO
OO
—O
AISC 360-10 TABLE N5.4-2
INSPECTION TASKS DURING WELDING
INSPECTION TASKS DURING WELDING QC QA
USE OF QUALIFIED WELDERS O
NO WELDING OVER CRACKED TACK WELDS
ENVIRONMENTAL CONDITIONS
• WIND SPEED WITHIN LIMITS
• PRECIPITATION AND TEMPERATURE
WELDING TECHNIQUES
O
• INTERPASS AND FINAL CLEANING
• EACH PASS WITHIN PROFILE LIMITATIONS
• EACH PASS MEETS QUALITY REQUIREMENTS
OO
OO
OO
OO
OO
CONTROL AND HANDLING OF WELDING CONSUMABLES
• PACKAGING
• EXPOSURE CONTROL
WPS FOLLOWED
• SETTINGS ON WELDING EQUIPMENT
• TRAVEL SPEED
• SELECTED WELDING MATERIALS
• SHIELDING GAS TYPE/FLOW RATE
• PREHEAT APPLIED
• INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)
• PROPER POSITION (F, V, H, OH)
AISC 360-10 TABLE N5.4-3
INSPECTION TASKS AFTER WELDING
INSPECTION TASKS AFTER WELDING QC QA
WELDS CLEANED O
ARC STRIKES
O
PP
PP
WELDS MEET VISUAL ACCEPTANCE CRITERIA
• CRACK PROHIBITION
• WELD/BASE-METAL FUSION
• CRATER CROSS SECTION
• WELD PROFILES
• WELD SIZE
• UNDERCUT
• POROSITY
SIZE, LENGTH AND LOCATION OF WELDS PP
K-AREA (1) PP
BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) PP
REPAIR ACTIVITIES PP
DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER PP
(1) WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 3 IN. (75 MM) OF THE WELD.
AISC 360-10 TABLE N5.6-1
INSPECTION TASKS PRIOR TO BOLTING
INSPECTION TASKS PRIOR TO BOLTING QC QA
MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS P
PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH
IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE)
O
FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS
PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL
CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION
AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS
PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED
AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED
PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER
COMPONENTS
OO
OO
OO
OO
OP
OO
AISC 360-10 TABLE N5.6-2
INSPECTION TASKS DURING BOLTING
INSPECTION TASKS DURING BOLTING QC QA
FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND
WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED
JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONG
OPERATION
FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING
FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION,
PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE
EDGES
OO
OO
OO
OO
AISC 360-10 TABLE N5.6-3
INSPECTION TASKS AFTER BOLTING
INSPECTION TASKS AFTER BOLTING QC QA
DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS PP
AISC 360-10 TABLE N6.1
INSPECTION OF STEEL ELEMENTS OF COMPOSITE
CONSTRUCTION PRIOR TO CONCRETE PLACEMENT
INSPECTION OF STEEL ELEMENTS OF COMPOSITE
CONSTRUCTION PRIOR TO CONCRETE PLACEMENT QC QA
PLACEMENT AND INSTALLATION OF STEEL DECK PP
PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS PP
DOCUMENT ACCEPTANCE OR REJECTION OF STEEL ELEMENTS PP
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/1
9/
2:
:3
PM
/2
2/
S-004M
ST
AT
EM
EN
T O
F
SP
EC
IA
L
IN
SP
EC
TI
O
N S
P.
M
AN
IS
R .Y
O U
N
KE
R C
. M C
G
EE
W W
YK
0 5
S-
4M .D
W G
P.
M
AN
IS
O = OBSERVE THESE ITEMS ON A RANDOM BASIC. OPERATIONS NEED NOT TO BE DELAYED PENDING THESE INSPECTIONS.
P = PERFORM THESE TASKS FOR EACH JOINT OR MEMBER.
QA = INSPECTION THAT THE WORK IS IN COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS
QC = INSPECTION THAT THE WORK IS PERFORMED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS ALL COSTS DUE TO SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2012, ACI 530-11 AND AISC 300-10 SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THIS INCLUDES ALL QC AND QA REQUIREMENTS INDICATED ON S-003H AND S-004H.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
GRID
OVERHANG A
2H 3H
2H 3H
SEE
NOTE 5
1. REFER TO GENERAL NOTES FOR WIND LOAD DESIGN CRITERIA.
2. WIND PRESSURES ARE IN SERVICE LEVEL (0.6*WL PER ASCE 7-10) AND
SHALL APPLY NORMAL TO MEMBER SERVICE.
3. PLUS AND MINUS (+/-) SIGNS SIGNIFY PRESSURES ACTING
TOWARD AND AWAY FROM SURFACE RESPECTIVELY.
4. EACH COMPONENT SHALL BE DESIGNED FOR MAXIMUM
POSITIVE AND NEGATIVE PRESSURES.
5. OVERHANG LOAD IS APPLIED TO EITHER SIDE BUT NOT SIMULTANEOUSLY ON BOTH SIDES.
6. ASSUMED ROOF SYSTEM DEAD LOAD IS 8 PSF.
7. "A" = 9 FEET.
GENERAL NOTES: THIS SHEET ONLY
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/1
9/
2:
:3
PM
/2
2/
S-005M
W
IN
D
IS
O D
IA
G
R
AM
P.
M
AN
IS
R .Y
O U
N
KE
R C
. M C
G
EE
W W
YK
0 5
S-
5M .D
W G
P.
M
AN
ISNTSSCALE:B1 WIND ISOMETRIC
5 5
DESIGN WIND PRESSURES (PSF)
WIND ZONE
ROOF DECK CMU WALL
MAX MIN MAX MIN
1 9.6 -20.4 - - 2 9.6 -34.2 - - 3 9.6 -51.5 - - 4 - - 15.0 -16.5 5 - - 15.0 -17.5
2H 9.6 -30.0 - - 3H 9.6 -48.4 - -
NTSSCALE:B5 WIND ISOMETRIC OVERHANG & NOTES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
1. REFER TO GENERAL NOTES FOR WIND LOAD DESIGN CRITERIA.
2. WIND PRESSURES ARE IN SERVICE LEVEL (0.6*WL PER ASCE 7-10) AND
SHALL APPLY NORMAL TO MEMBER SERVICE.
3. PLUS AND MINUS (+/-) SIGNS SIGNIFY PRESSURES ACTING
TOWARD AND AWAY FROM SURFACE RESPECTIVELY.
4. EACH COMPONENT SHALL BE DESIGNED FOR MAXIMUM
POSITIVE AND NEGATIVE PRESSURES.
5. OVERHANG LOAD IS APPLIED TO EITHER SIDE BUT NOT SIMULTANEOUSLY ON BOTH SIDES.
6. ASSUMED ROOF SYSTEM DEAD LOAD IS 8 PSF.
7. "A" = 9 FEET.
GENERAL NOTES: THIS SHEET ONLY
GRID
OVERHANG A
2H 3H
2H 3H
SEE
NOTE 5
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/1
9/
2:
:3
PM
/2
2/
S-006M
W
IN
D
IS
O D
IA
G
R
AM
P.
M
AN
IS
R .Y
O U
N
KE
R C
. M C
G
EE
W W
YK
0 5
S-
6M .D
W G
P.
M
AN
IS
NTSSCALE:B1 WIND ISOMETRIC
DESIGN WIND PRESSURES (PSF)
WIND ZONE
ROOF DECK CMU WALL
MAX MIN MAX MIN
1 9.6 -20.4 - - 2 9.6 -34.2 - - 3 9.6 -51.5 - - 4 - - 15.0 -16.5 5 - - 15.0 -17.5
2H 9.6 -30.0 - - 3H 9.6 -48.4 - -
NTSSCALE:B5 WIND ISOMETRIC OVERHANG & NOTES
5 5
5 5
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
EXTERIOR SLAB ON
GRADE, PER CIVIL DWGS
1'-0"
2' -0
PER MECHANICAL
PLANS, 4" MIN
ISOLATORS AND
ANCHOR BOLTS
(GALVANIZED) PER
MECH UNIT SUPPLIER
MECH UNIT SEE
MECH PLANS
#4 BARS @ 12" OC
EACH WAY TOP AND BOTTOM
0' - 1"
0'
7/
0'
3/
SEE NOTE 1
SEE NOTE 2
PIPE PER CIVIL
2.
1.
COMPACTED FILL PER SPECIFICATIONS.
TYP SLAB REINF PER PLAN.
NOTES
"T
"T " M
IN6" MIN
"T " M
IN
3. SEE OTHER DISCIPLINE DRAWINGS FOR PIPE LOCATIONS.
STEM WALL
CONCRETE
FOUNDATION
SLEEVE. PROVIDE 1/2" MIN.
CLEARANCE AROUND PIPE
PIPE, SEE OTHER DISCIPLINE
DRAWINGS FOR PIPE INFORMATION
CONCRETE FILL TO
BE PLACED BEFORE
FOUNDATION IS POURED
AND POUR FULL WIDTH
OF PIPE TRENCH.
STEM WALL
AS OCCURS
CONCRETE FOOTING
OR FOUNDATION
SLEEVE. PROVIDE 1/2" MIN.
CLEARANCE AROUND PIPE
PIPE
CONCRETE FILL TO BE PLACED
BEFORE FOOTING IS POURED AND
POUR FULL WIDTH OF PIPE TRENCH.
1/ 2"
M
IN
8" MIN., 3'-0" MAX. WHERE DEPTH IS
GREATER THAN 3'-0" SEE DETAIL "PIPE
PASSING BELOW CONT. FOOTING"
THIS SHEET WHERE DEPTH IS LESS
THAN 8". SEE DETAIL "PIPE BELOW
SLAB ON GRADE"
PIPES SHALL NOT PASS THRU GRADE BEAMS.
0'
/3 2"
0'
1/
2"
A
SECTION A
STEM WALL
AS OCCURS
CONCRETE FOOTING
OR FOUNDATION
1'-6" MAX. WHERE TRENCH
EXCEEDS 1'-6" NOTIFY
STRUCTURAL ENGINEER PRIOR
TO PLACEMENT OF FOOTING.
SELECT BACKFILL AND
RECOMPACT TRENCH
PER SPECIFICATIONS.
BOTTOM OF TRENCH
0'
0' - 1 17/32"
GREATER THAN 3'-0". SEE DETAIL
"PIPE PASSING UNDER
CONT. FOOTING" THIS SHEET
FOR DEPTHS 3'-0" AND LESS.
SEE OTHER DISCIPLINE DRAWINGS
FOR PIPE INFORMATION
SECTION
EP-1
NOTES:
1. PROVIDE EP-1 EQUIPMENT PAD FOR INTERIOR EQPT WHERE
INDICATED ON OTHER DISCIPLINE DWGS.
2. PROVIDE NUMBER OF DOWELS TO MATCH TOTAL CROSS-SECTIONAL
AREA OF ANCHOR BOLTS, EQUALLY SPACED AROUND PAD, EXCEPT
THAT SPACING OF DOWELS SHALL NOT EXCEED 12".
3. IF FLOOR SLAB IS CONSTRUCTED BEFORE DOWELS ARE PLACED,
DOWELS SHALL BE EPOXY GROUTED INTO FLOOR SLAB.
4. EQPT SHALL BE GROUTED IN PLACE W/ NON-SHRINK GROUT UNLESS
OTHERWISE RECOMMENDED BY EQPT MFR.
5. EQPT ANCHOR BOLTS SHALL BE STANDARD TYPE V
BOLTS, UNLESS OTHERWISE RECOMMENDED BY EQPT MFR.
6. HEIGHT OF PAD ABOVE SURROUNDING FLOOR SLAB SHALL BE 4" MIN.
3/4" CHAMFER
BUSH-HAMMER ROUGH UNDER
AREA OF FOUNDATION AND
APPLY BONDING COMPOUND
#4 @ 12" EW TOP
#4 DOWELS
SEE NOTES 2 & 3
6" M
AX
4" TO EQUIPMENT BASE
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
B U
R N
S
M C
D O
N N
E
LL
W
AR
D P
A R
KW
AY
K
AN
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
SHEET
IDENTIFICATION
S O
LI
C
IT
AT
IO
N
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
S
IZ
E:
SB
M
T
BY
P
LO
T
SC
AL
E:
P
LO
T D
AT
E:
C O
N
TR
AC
T
N O
KC
-4
6A D
E P O
T M
AI
N
T C
O M
PL
E X
M
EC
H S
YS
TE
M S
BL
D
G
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
TI
N
KE
R
A
IR
FO
R
C E
BA
S E
PD
C
:W W
YK
FY
: 1
1:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
W
2B V-
-R
-0
/1
9/
2:
:3
PM
/2
2/
S-007M
ST
AN
D
AR
D F
O U
N D
AT
IO
N D
ET
AI
LS
P.
M
AN
IS
R .Y
O U
N
KE
R C
. M C
G
EE
W W
YK
0 5
S-
7M .D
W G
P.
M
AN
IS
NTSSCALE:E2 EXTERIOR EQUIPMENT PAD
NTSSCALE:A3 PIPE BELOW SLAB ON GRADE
NTSSCALE:A1 PIPE PASSING UNDER CONT. FOOTING (LESS THAN 3'-0)
NTSSCALE:A4
PIPE PASSING BELOW CONT. FOOTING
(GREATER THAN 3'-0)
NTSSCALE:D1 INTERIOR EQUIPMENT PAD FOUNDATION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
D = BOLT DIAMETER
K = THREADS (2D+3" SINGLE NUT)
= THREADS (3D+3" DOUBLE NUTS)
P = BOLT PROJECTION,SEE
FOUNDATION SCHEDULE
0' - 0 3/4"
0'
/3 2"
0'
2" 0'
3/ 4"
0'
1/
2"
D
K
P B
A
TOC ELEVATION AS
NOTED ON PLANS
SQUARE PL
DAMAGE LAST THREAD
TO PREVENT REMOVAL
OF BOLT
TYPE II ANCHOR BOLT
UNSLEEVED BOLT
WELD
3 PTS
D 5/8" 3/4"
1" 7/8"
1 1/8" 1 1/4" 1 1/2"
SCHEDULE
A 2" 2" 3" 3" 3" 3" 4"
B 8" 10"
1'-10" 1'-0"
2'-0" 2'-2" 2'-4"
SQUARE PL
PL 1/2"x2 1/2" SQ
PL 1/2"x3" SQ PL 5/8"x3 1/2" SQ PL 5/8"x3 1/2" SQ
PL 3/4"x4" SQ PL 3/4"x4 1/2" SQ PL 7/8"x5 1/2" SQ
REMARKS
ASTM F1554
GRADE 55, TYP
HEAVY HEX NUT
WASHER THICKNESS PER
AISC 360-10 TABLE 14-2
STANDARD REINFORCEMENT DETAILS
VERTICAL WALL TO SLAB CORNER
AND INTERSECTION REINFORCEMENT DETAILS
SEE CORNER REINFORCEMENT NOTE 3
CORNER REINFORCEMENT NOTES:
1. UNLESS OTHERWISE INDICATED, THE CONTRACTOR HAS
THE OPTION OF REINFORCING CORNERS IN ACCORDANCE
WITH OPTION #1 OR OPTION #2.
2. UNLESS OTHERWISE INDICATED, THE CONTRACTOR HAS
THE OPTION OF CONSTRUCTING INTERSECTIONS WITH
OR WITHOUT CONSTRUCTION JOINTS. REINFORCE PER
APPLICABLE DETAIL.
3. INDICATES CONTRACTOR OPTION: WITH OR
WITHOUT LAP SPLICE AT THESE LOCATIONS.
ELEVATION
VERT REINF
NOT SHOWN
ELEVATION
DOWEL
VERT REINF
NOT SHOWN
VERT REINF
NOT SHOWN
ELEVATION ELEVATION
DOWEL TYP
VERT REINF
NOT SHOWN
LA
P
SP
LI
C E
LA
P
SP
LI
C E
LAP
SPLICE
LA
P
SP
LI
C E
LA
P
SP
LI
C E
LAP SPLICE
HORIZONTAL WALL REINFORCEMENT DETAILS
INTERSECTIONS
SEE CORNER REINFORCEMENT NOTE 2
PLAN
WITHOUT CJ
PLAN
WITH CJ
PLAN
WITHOUT CJ
PLAN
WITH CJ
VERT REINF
NOT SHOWN
VERT REINF
NOT SHOWN
VERT REINF
NOT SHOWN
VERT REINF
NOT SHOWN
DOWEL TYP
LA
P
SP
LI
C E
STD 90°
HOOK UNO
DOWEL
HORIZONTAL WALL REINFORCEMENT DETAILS
CORNERS
SEE CORNER REINFORCEMENT NOTE 1
PLAN
OPTION #1
PLAN
OPTION #2
PLAN
OPTION #1
PLAN
OPTION #2
VERT REINF
NOT SHOWN
VERT REINF
NOT SHOWN
VERT REINF
NOT SHOWN
VERT REINF
NOT SHOWN
LAP SPLICE LAP SPLICE
LA
P
SP
LI
C E
CORNER BAR
STD 90°
HOOK
WHERE
INDICATED
LAP SPLICE LAP SPLICE
LA
P
SP
LI
C E
STD 90°
HOOK
WHERE
INDICATED
STD 90°
HOOK UNO
STD 90°
HOOK UNO
STD 90°
HOOK UNO
STD 90°
HOOK UNO
STD 90°
HOOK UNO
LA
P
SP
LI
C E
TOP
DEVELOPMENT LENGTH
REINFORCING DEVELOPMENT AND SPLICES
f'c=4500psi
1'-6" 2'-0"
2'-11" 2'-6"
4'-11"
6'-3" 6'-11"
5'-7"
4'-4"
1'-2"#3
#11 #10
#8 #9
#6 #7
#4 #5
3'-9" 4'-4"
5'-4" 4'-10"
1'-7"
2'-3" 1'-11"
3'-4"
BAR
SIZE OTHER
1'-11"1'-6"
4'-11"
6'-11"
5'-7" 6'-3"
2'-11" 4'-4"
2'-0" 2'-6"
6'-4"
8'-11"
7'-2" 8'-1"
3'-10" 5'-7"
2'-7" 3'-2"
SPLICE LENGTH
OTHER TOP
- MAIN REINF
- LAPPED REINF
7"#3
#8
#10 #11
#9
#5
#7 #6
#4
1'-7"
2'-0" 2'-3"
1'-10"
1'-0" 1'-3" 1'-5"
10"
DEVELOPMENT LENGTHS
HOOKED BARS (f'c = 4500psi)
LENGTH OR
MIN EMBEDMENTBAR SIZE
TYPICAL REINFORCING NOTES:
1. REINFORCING BAR DEVELOPMENT AND LAP SPLICE LENGTHS SHALL
BE AS SHOWN IN THESE TABLES UNLESS NOTED OTHERWISE ON
THE DRAWINGS.
2. THE LENGTHS SHOWN IN THE TABLES ARE BASED ON THE FOLLOWING
CONCRETE COVERAGE AND REINFORCING C-C SPACING:
BEAMS OR COLUMNS: COVER ≥ 1.0bd (BAR DIAMETER)
CENTER TO CENTER (C-C) SPACING ≥ 2.0bd ALL OTHERS: COVER ≥ 1.0bd
CENTER TO CENTER SPACING > 3.0 bd
3. TOP BARS ARE DEFINED AS HORIZONTAL REINFORCEMENT PLACED
SUCH THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE
MEMBER BELOW THE DEVELOPMENT LENGTH OR SPLICE.
4. THE DEVELOPMENT AND SPLICE LENGTHS SHOWN SHALL NOT
APPLY IF ANY OF THE FOLLOWING CONDITIONS OCCUR:
A) f'c < 4500 psi B) fy > 60,000 psi
C) THE COVER OR C-C BAR SPACING IS NOT AS LISTED ABOVE.
D) THE REINFORCING STEEL IS EPOXY COATED.
E) LIGHT WEIGHT CONCRETE IS USED.
5. WHERE BAR SPLICES ARE STAGGERED SUCH THAT ONE-HALF OR LESS
OF TOTAL REINFORCEMENT IS SPLICED WITHIN REQUIRED LAP LENGTH.
SPLICE LENGTH MAY EQUAL DEVELOPMENT LENGTH.
6. CENTER TO CENTER SPACING(S) IS DEFINED AS BELOW:
LE
N
G
TH
CRITICAL
SECTION
12X DIA OF BAR
LE
N
G
TH
0'
5/
4x D
IA
O
F
BA
R O
R
/2
" M
IN
RADIUS OF HOOK:
4x DIA OF BAR - #3 TO #8 BARS 5x DIA OF BAR - #9 TO #11 BARS 6x DIA OF BAR - #14 & #18 BARS
M
IN
EM
BE
D M
EN
T LA
P
SP
LI
C
E
SE
E
N O
TE
LA
P
SP
LI
C
EHOOKED BAR
DETAIL 1 DETAIL 2
DEVELOPMENT LENGTH NOTES:
1. WHERE DWGS ARE DETAILED SIMILIAR TO DETAIL 2,
EXTEND THE EMBEDMENT LENGTH SUCH THAT THE
HOOKED BAR CONTACTS THE LAYER OF MAIN
REINFORCING SHOWN.
2. EMBEDMENT LENGTHS IN CHART ARE TYPICAL
EXCEPT AS NOTED IN DETAIL 2, OR AS INDICATED
ON DRAWINGS.
0' - 1 1/8""S"
SLOPE
FD
SLOPE
SL
O
PERAD=18"
SLOPE 1/2"
TO DRAIN
CONTRACTOR SHALL COORDINATE DRAIN
LOCATIONS WITH OTHER…