11B0002-SPECS-AM3.PDF
PDF 168 KB Posted
- Solicitation number
- W912BU-11-B-0002
About this file
11B0002-Spec-Amend3
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 11B0002-SPECS-AM6.PDF | ||
| 11B0002-DWGS-AM6.PDF | ||
| 11B0002-Amend5.pdf | ||
| 11B0002-DWGS-AM4.PDF | ||
| 11B0002-SPECS-AM4.PDF | ||
| 11B0002-DWGS-AM3.PDF | ||
| 11B0002-DWGS-AM2.PDF | ||
| 11B0002-SPECS-AM2.PDF | ||
| Bldg12-site visit.pdf | ||
| 11B0002amnd1.pdf | ||
| 11B0002-SPECS-VOL2.PDF | ||
| 11B0002-DWGS.pdf | ||
| RFI Example.xls | XLS spreadsheet | |
| 11B0002-SPECS-VOL1.PDF | ||
| 00843 Topo Survey Plan - Full Size.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
THIS AMENDMENT EXTENDS THE BID OPENING DATE TO: 16 DECEMBER 2010 AT 2:00 P.M. EST
(CONTINUED)
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
MODIFICATION OF CONTRACTS/ORDER
NO.
E. IMPORTANT: Contractor
15B. CONTRACTOR/OFFEROR
is not, copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer tended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDG- MENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
is extended, B.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CON-
TRACT ORDER NO. IN ITEM 10A.
2. AMENDMENT/MODIFICATION NO.
6. ISSUED BY
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) is required to sign this document and return
15A. NAME AND TITLE OF SIGNER (Type or print)
PAGE OF PAGES 1. CONTRACT ID CODE
5. PROJECT NO. (If applicable) 4. REQUISITION/PURCHASE REQ. NO. 3. EFFECTIVE DATE
7. ADMINISTERED BY (If other than Item 6)
15C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16B. UNITED STATES OF AMERICA
BY
16C. DATE SIGNED
9A. AMENDMENT OF SOLICITATION NO.
9B. DATED (SEE ITEM 11)
10B. DATED (SEE ITEM 13)
CODE CODE
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
is not ex-copies to the issuing office.
NSN 7540-01-152-8070
PREVIOUS EDITION UNUSABLE
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
(Signature of person authorized to sign) (Signature of Contracting Officer)
USAPPC V2.00
10A.
30-105-02
U.S. ARMY ENGINEER DISTRICT, PHILADELPHIA
POC: EMILY SHEAFFER
WANAMAKER BUILDING, 100 PENN SQUARE EAST
PHILADELPHIA, PA 19107-3390
U.S. ARMY ENGINEER DISTRICT, PHILADELPHIA
CONTRACTING DIVISION, ROOM 643
WANAMAKER BUILDING, 100 PENN SQUARE EAST
PHILADELPHIA, PA 19107-3390
CODE
W912BU E5CTCEMS
FACILITY CODE
0003 06 December 2010
W912BU-11-B-0002
10 NOVEMBER 2010
Building 12 Renovations, Tobyhanna Army Depot, Tobyhanna, Pennsylvania
This page was intentionally left blank for duplex printing.
Amendment No. 0003
IFB W912BU-11-B-0002
14. DESCRIPTION OF AMENDMENT (continued)
a. VOLUME 1 OF 2:
(1) BIDDING SCHEDULE: Please delete the Bidding Schedule in its entirety and substitute the revised Bidding Schedule, annotated Amendment No. 0003, attached hereto.
(2) Section 08 71 00 – DOOR HARDWARE: Please delete section 08 71 00 in its entirety and substitute revised section 08 71 00, annotated Amendment No. 0003, attached hereto.
(3) Section 09 29 00 – GYPSUM BOARD: Please delete section 09 29 00 in its entirety and substitute revised section 09 29 00, annotated Amendment No. 0003, attached hereto.
(4) Section 28 31 64 – FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE: Please delete section 28 31 64 in its entirety and substitute revised section 28 31 64, annotated Amendment No. 0003, attached hereto.
b. VOLUME 2 OF 2:
(1) Section 28 31 64 – FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE: Please delete section 28 31 64 in its entirety and substitute revised section 28 31 64, annotated Amendment No. 0003, attached hereto.
c. CONTRACT DRAWINGS: Please delete the following drawings in their entirety and substitute the revised drawings of the same numbers, with the latest revision date of 6 December 2010, attached hereto:
12-1-47 12-1-50 12-1-53 12-1-56 12-1-57 12-1-61 12-5-36 12-5-37
d. Please indicate receipt of this amendment on Standard Form 1442(SOLICITATION, OFFER, AND AWARD) as Amendment No. 0003. Failure to acknowledge all amendments may be cause for rejection of the offer.
BID SCHEDULE
(To be attached to SF 1442)
Item Estimated Unit Estimated No. Description Quantity Unit Price Amount
00010-1
BASE BID:
1. Building 12 Renovation (all Building work except Items 2, 3 and 4 below) 1 Job LS $
2. Concrete Foundation Repair Type A 130 SF $ $
3. Concrete Foundation Repair Type B 20 SF $ $
4. Roof Deck Replacement 1000 SF $ $
5. Sitework 1 Job LS $
OPTION 1:
6. Diesel Generator with Automatic Transfer Switch and Uninterruptable Power Supply 1 Job LS $
TOTAL ESTIMATED BASE BID AND OPTION 1 AMOUNT: $ __________
NOTES:
1. Bidders must bid on all items.
SECTION 08 71 00
DOOR HARDWARE
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
BHMA A156.1 (2006) Butts and Hinges
BHMA A156.13 (2005) Mortise Locks & Latches, Series 1000
BHMA A156.15 (2006) Closer Holder Release Devices
BHMA A156.16 (2008) Auxiliary Hardware
BHMA A156.18 (2006) Materials and Finishes
BHMA A156.21 (2006) Thresholds
BHMA A156.22 (2005) Door Gasketing and Edge Seal Systems
BHMA A156.3 (2008) Exit Devices
BHMA A156.4 (2008) Door Controls - Closers
BHMA A156.5 (2001) Auxiliary Locks & Associated Products
BHMA A156.6 (2005) Architectural Door Trim
BHMA A156.7 (2003) Template Hinge Dimensions
BHMA A156.8 (2005) Door Controls - Overhead Stops and Holders
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2009; Amd 09-1 & 09-2) Life Safety Code
NFPA 80 (2010) Standard for Fire Doors and Other Opening Protectives
SECTION 08 71 00 Page 1
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames
UNDERWRITERS LABORATORIES (UL)
UL 14C (2006; Rev thru Dec 2008) Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs
UL Bld Mat Dir (2010) Building Materials Directory
1.2 SUBMITTALS
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES.
SD-02 Shop Drawings
Hardware schedule; G Keying system
SD-03 Product Data
Hardware items; G
SD-08 Manufacturer's Instructions
Installation
SD-10 Operation and Maintenance Data
Hardware Schedule items, Data Package 1; G Submit data package in accordance with Section 01 78 23 EQUIPMENT
OPERATING, MAINTENANCE, AND REPAIR MANUALS.
SD-11 Closeout Submittals
Key Bitting
1.3 HARDWARE SCHEDULE
Prepare and submit hardware schedule in the following form:
Reference Mfr. UL Mark Publi- Name Key (If fire BHMA Hard- cation and Con- rated Finish ware Quan- Type Catalog trol and Designa- Item tity Size No. Finish No. Symbols listed) tion
1.4 KEY BITTING CHART REQUIREMENTS
Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:
a. Complete listing of all keys (AA1, AA2, etc.).
SECTION 08 71 00 Page 2
b. Complete listing of all key cuts (AA1-123456, AA2-123458).
c. Tabulation showing which key fits which door.
d. Copy of floor plan showing doors and door numbers.
e. Listing of 20 percent more key cuts than are presently required in each master system.
1.5 QUALITY ASSURANCE
1.5.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, pivots, and closers of one lock, hinge, pivot, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.5.1 Key Shop Drawings Coordination Meeting
Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware subcontractor, using Activity and Base Locksmith shall meet to discuss key requirements for the facility.
1.6 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown in hardware schedule. Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Provide hardware to be applied to shop manufactured doors as required by door manufacturer to template. Promptly furnish template information or templates to door and frame manufacturers. Conform to BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 80 for fire doors and NFPA 101 for exit doors, as well as to other requirements indicated, even if such hardware is not specifically mentioned under paragraph entitled "Hardware Schedule." Conform to UL 14C for swinging hardware for the tin-clad fire doors. Provide the label of Underwriters Laboratories, Inc. for such hardware listed in UL Bld Mat Dir or labeled and listed by another testing laboratory acceptable to the Contracting Officer.
2.3 HARDWARE ITEMS
Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark will be visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover.
SECTION 08 71 00 Page 3
2.3.1 Hinges
BHMA A156.1, 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for exterior doors and reverse-bevel interior doors so that pins will be nonremovable when door is closed. Other antifriction bearing hinges may be provided in lieu of ball-bearing hinges.
2.3.2 Locks and Latches
2.3.2.1 Mortise Locks and Latches
BHMA A156.13, Series 1000, Operational Grade 1, Security Grade 2. Install levers of mortise locks with screwless shanks and no exposed screws.
2.3.3 Exit Devices
BHMA A156.3, Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons, not less than 7 by 2-1/4 inch.
2.3.4 Cylinders and Cores
Provide cylinders and cores with seven pin tumblers. Provide cylinders from products of one manufacturer, and provide cores from the products of one manufacturer. Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.
2.3.5 Keying System
Provide a grand master keying system Provide construction interchangeable cores. Provide key cabinet as specified.
Provide sub-master keying system for each building, and keyed to the existing Schlage removable-core master and grand master keying systems or equal, pending acceptance testing with the current TYAD system. Key equipment spaces and mechanical rooms separately from the building systems, and keyed alike to the existing Best master and grand master systems for these doors.
2.3.6 Lock Trim
Cast, forged, or heavy wrought construction and commercial plain design.
2.3.6.1 Lever Handles
Provide lever handles in lieu of knobs. Conform to the minimum requirements of BHMA A156.13 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
2.3.6.2 Texture
Provide knurled or abrasive coated knobs or lever handles for doors which
SECTION 08 71 00 Page 4 are accessible to blind persons and which lead to dangerous areas.
2.3.7 Keys
Furnish seven change keys for each interchangeable core, furnish two control keys, six maters keys, and six construction master keys. Furnish a quantity of key blanks equal to 20 percent of the total number of change keys. Stamp each key with appropriate key control symbol and "U.S.
property - Do not duplicate." Do not place room numbers on keys.
2.3.8 Door Bolts
BHMA A156.16. Provide dustproof strikes for bottom bolts, except for doors having metal thresholds. Surface bolts shall be used where required on exterior doors where scheduled Automatic latching flush bolts: BHMA A156.3, Type 25.
2.3.9 Closers
BHMA A156.4, Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, and other features necessary for the particular application. Size closers in accordance with manufacturer's recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.
2.3.9.1 Identification Marking
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation located to be visible after installation.
2.3.10 Overhead Holders
BHMA A156.8.
2.3.11 Closer Holder-Release Devices
BHMA A156.15.
2.3.12 Door Protection Plates
BHMA A156.6.
2.3.12.1 Sizes of Mop and Kick Plates
2 inch less than door width for single doors; one inch less than door width for pairs of doors.
2.3.13 Door Stops and Silencers
BHMA A156.16. Silencers Type L03011. Provide three silencers for each single door, two for each pair.
2.3.14 Thresholds
BHMA A156.21. Use J36130, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.
SECTION 08 71 00 Page 5
2.3.15 Weather Stripping Gasketing
BHMA A156.22. Provide the type and function designation where specified in paragraph entitled "Hardware Schedule". Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weather stripped doors not to exceed 1.25 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E 283.
2.3.16 Soundproofing Gasketing
BHMA A156.22. Include adjustable doorstops at head and jambs and an automatic door bottom per set, both of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed-cell sponge gasket. Furnish door bottoms with adjustable operating rod and silicone rubber or closed-cell sponge neoprene gasket. Doorstops mitered at corners. Provide the type and function designation where specified in paragraph entitled "Hardware Sets".
2.3.17 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, required to service and adjust hardware items.
2.4 FASTENERS
Provide fasteners of proper type, quality, size, quantity, and finish with hardware. Provide stainless steel or nonferrous metal fasteners that are exposed to weather. Provide fasteners of type necessary to accomplish a permanent installation.
2.5 FINISHES
BHMA A156.18. Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 630 finish. Match exposed parts of concealed closers to lock and door trim.
Match hardware finish for aluminum doors to the doors.
2.6 KEY CABINET AND CONTROL SYSTEM
BHMA A156.5, Type E8351 (150 hooks.
PART 3 EXECUTION
3.1 INSTALLATION
Install hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.
Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.
SECTION 08 71 00 Page 6
3.1.1 Weather Stripping Installation
Handle and install weather stripping to prevent damage. Provide full contact, weather-tight seals. Operate doors without binding.
3.1.1.1 Stop-Applied Weather Stripping
Fasten in place with color-matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.
3.1.2 Soundproofing Installation
Install as specified for stop-applied weather stripping.
3.1.3 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves.
3.2 FIRE DOORS AND EXIT DOORS
Install hardware in accordance with NFPA 80 for fire doors, NFPA 101 for exit doors , and UL 14C for swinging tin-clad fire doors.
3.3 HARDWARE LOCATIONS
SDI/DOOR A250.8, unless indicated or specified otherwise.
a. Kick Plates: Push side of single-acting doors.
b. Mop Plates: Bottom flush with bottom of door.
3.4 KEY CABINET AND CONTROL SYSTEM
Locate where indicated. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Furnish complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.5 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, as directed, errors in cutting and fitting and damage to adjoining work.
3.6 HARDWARE SETS
SECTION 08 71 00 Page 7
Provide hardware for aluminum doors under this section. Deliver Hardware templates and hardware, except field-applied hardware to the aluminum door and frame manufacturer for use in fabricating the doors and frames.
Exterior Glazed Doors must meet ATFP requirements. Doors tested with specific hardware to meet these requirements must be installed with the hardware as tested.
Hardware Set 1 Exterior Doors: 101A,101B,118A,118B (Glazed Aluminum Single Doors w/CR)
4 Butt Hinges A5111 4 1/2 x 4 1/2 NRP (by door mfg.) 630 1 Exit Device Type 4, Function 04 with Latch Retraction 630 1 Door Pull J402 630 1 Rim Cylinder Per Facility Requirements 626 1 Closer C02041 689 1 Overhead Stop C04541 630 1 Power Supply 24 Volt For Latch Retraction Exit Device 1 Balanced Magnetic Switch Coordinate with Security 630/626 1 Gasket ROE154 x LAR (Head & Jambs) 1 Card Reader Coordinate with Security 1 Threshold J36130 must be as tested for blast 1 Wiring Diagram WITH POINT TO POINT DRAWING
Note: Perimeter gasket by door/frame manufacturer, card reader and balanced magnetic switches by Security Section 28 20 01.00 10 "ELECTRONIC SECURITY SYSTEM" Subpart 2.8.1 "Card Readers and Credential Cards". Coordinate latch retraction exit device with access control system. Provide power transfer hinge as required by door manufacturer to meet blast resistance.
Coordinate with access control system and with Security Officer.
Hardware Set 2 Not Used
Hardware Set 3 Exterior Doors: ST1-1B (HM Exit Only Single Doors)
3 Butt Hinges A5111 4 1/2 x 4 1/2 NRP (by door mfg.) 630 1 Exit Device Type 1, Function 01 630 1 Door Pull J402 630 1 Rim Cylinder Per Facility Requirements 626 1 Closer C02041 689 1 Overhead Stop C04541 630 1 Balanced Magnetic Switch Coordinate with Security 630/626 1 Gasket ROE154 x LAR (Head & Jambs) 1 Threshold J36130 must be as tested for blast
Note: Perimeter gasket by door/frame manufacturer, balanced magnetic switches by Security Section 28 20 01.00 10 "ELECTRONIC SECURITY SYSTEM".
Coordinate Keying with Security Officer.
Hardware Set 4 Exterior Door: ST2-1C (Ext. HM Door Double Exit Only)
6 Hinges A5111 4 1/2 x 4 1/2 NRP 630 2 Exit Device Type 1, Function 01 630 2 Closers C02021 689 2 Kickplates J102 8" x 2" LDW B4E CSK 630 2 Balanced Magnetic Switches Coordinate with Security 630 2 Concealed OH Stops C01541 630 1 Gasket ROE154 x LAR (Head & Jambs) 1 Threshold J36130
1 Removable Mullion Type 22, Keyed Blast Resistant Match Frame
SECTION 08 71 00 Page 8
Note: Perimeter gasket and Removable Mullion by door/frame manufacturer, balanced magnetic switches by Security Section 28 20 01.00 10 "ELECTRONIC
SECURITY SYSTEM".
Hardware Set 5 Exterior Doors: 120A (Ext. HM Mech. Rm. Dbl. Door)
6 Hinges A5111 4 1/2 x 4 1/2 NRP 630 2 Surface Bolts L04161 630 1 Storeroom Lock F07 630 1 Mortise Cylinder Per Facility Requirements 626 2 Closer C02021 689 2 Kickplate J102 8" x 2" LDW B4E CSK 630 2 Overhead Holder C01511 630 2 Balanced Magnetic Switches Coordinate with Security 630 1 Astragal ROE714 SP x LAR 1 Gasket ROE154 x LAR (Head & Jambs) 1 Threshold J36130 x LAR
Hardware Set 6 Exterior Doors: 127C (Ext. HM Door Lever Keyed)
3 Hinges A5111 4 1/2 x 4 1/2 NRP 630 1 Storeroom Lock F07 630 1 Mortise Cylinder Per Facility Requirements 626 1 Closer C02021 689 1 Kickplate J102 8" x 2" LDW B4E CSK 630 1 Balanced Magnetic Switch Coordinate with Security 630 1 Concealed OH Stop C01541 630 1 Gasket ROE154 x LAR (Head & Jambs) 1 Threshold J36130
Hardware Set 7 Doors: 113A, 115A (Multiple Stall Toilet Rm.)
3 Butt Hinges A8111 4 1/2 x 4 1/2 652 1 Door Pull J405 4" x 16" 630 1 Push Plate J301 4" x 16" 630 1 Closer C02021 689 1 Kickplate J102 8" x 2" LDW B4E CSK 630 1 Mop Plate J103 4" x 1" LDW B4E CSK 630 1 Wall Stop L02251 630 3 Door Silencers L03011
Hardware Set 8 Doors: 116A (Interior Privacy Shower Room)
3 Butt Hinge A8112 4 1/2 x 4 1/2 652 1 Privacy Set F22 x Occupancy Indicator 626 1 Kickplate J102 8" x 2" LDW B4E CSK 630 1 Mop Plate J103 4" x 1" LDW CSK B4E 630 1 Wall Stop L02251 630 3 Door Silencers L03011
Hardware Set 9 Doors: 105A,106A,108A,110A,111A,114A (Classroom Door w / Closer)
3 Butt Hinges A8111 4 1/2 x 4 1/2 652 1 Classroom Lock F05 626 1 Mortise Cylinder Per Facility Requirements 626 1 Closer C02021 689 1 Kickplate J102 8" x 2" LDW B4E CSK 630
SECTION 08 71 00 Page 9
1 Kick Down Stop L01382 626 1 Wall Stop L02251 630 3 Door Silencers L03011
Hardware Set 9A Doors: 103A,104A,107A,123A,124A,125A,126B,127A (Classroom Door w cardreader and Closer)
3 Butt Hinges A8111 4 1/2 x 4 1/2 652 1 Classroom Lock F05 626 1 Mortise Cylinder Per Facility Requirements 626 1 Closer C02021 689 1 Kickplate J102 8" x 2" LDW B4E CSK 630 1 Kick Down Stop L01382 626 1 Wall Stop L02251 630 1 Power Supply 24 Volt For Card Reader Electric Strike 1 Balanced Magnetic Switch Coordinate with Security 630/626 1 Gasket ROE154 x LAR (Head & Jambs) 1 Card Reader Coordinate with Security 1 Electric Strike A156.31, Grade 1, Mortised 630 1 Door Bottom Sweep R3A434 x LAR
Notes: Door, frame, hinges, gaskets, door bottomand sound seals by Acoustic Door manufacturer to provide minimum STC-40 rating. Electronic opening to operate as follows: A cardreader is swiped to unlock an electric strike and provide access to the room. Egress from inside the space is constant at all times with operation of an ABA/ADA/NFPA compliant lever that will mechanically unlock the latch and deadbolt.
Hardware Set 10 Doors: 109B,112A,121A,121B (Wood Single Passage Doors)
3 Hinges A8112 4 1/2 x 4 1/2 652 1 Passage Latch F01 626 1 Wall Stop L02251 626 3 Door Silencers L03011
Hardware Set 11 Doors: 109A (Wood Double Closet Doors)
6 Hinges A5111 4 1/2 x 4 1/2 652 2 Surface Bolts L04161 626 1 Passage Latch F01 626 1 Wall Stop L02251 626 4 Door Silencers L03011
Hardware Set 12 Doors: ST1-1B,ST2-1A,ST1-2A,ST2-2A (Interior Fire Rated HM Single Exit)
3 Hinges A5111 4 1/2 x 4 1/2 652 1 Exit Device Type 1, Function 23 630 1 Closer C02021 689 1 Kickplate J102 8" x 2" LDW B4E CSK 630 1 Wall Stop L02251 626 1 Gasket ROE154 x LAR (Head & Jambs) 1 Threshold J36130
Hardware Set 12A Doors: ST1-1A,ST2-1A,ST2-1B (Interior Fire Rated HM Single Exit)
3 Butt Hinges A5111 4 1/2 x 4 1/2 NRP (by door mfg.) 652 1 Exit Device Type 1, Function 04 630
SECTION 08 71 00 Page 10
1 Door Pull J402 630 1 Rim Cylinder Per Facility Requirements 626 1 Closer C02041 689 1 Wall Stop L02251 626 1 Power Supply 24 Volt For Card Reader Electric Strike 1 Gasket ROE154 x LAR (Head & Jambs) 1 Card Reader Coordinate with Security 1 Electric Strike A156.31, Grade 1, Surface Mounted 630 1 Threshold J36130 must be as tested for blast 1 Wiring Diagram WITH POINT TO POINT DRAWING
Note: Perimeter gasket by door/frame manufacturer, card reader by Security Section 28 20 01.00 10 "ELECTRONIC SECURITY SYSTEM" Subpart 2.8.1 "Card Readers and Credential Cards". Coordinate Electric Strike exit device with access control and intrusion detection system. Coordinate with Security Officer.
Hardware Set 13 Exterior Door: 200A (Exterior HM Double Loading Door)
6 Hinges A5111 4 1/2 x 4 1/2 NRP 630 1 Storeroom Lock F30 630 1 Mortise Cylinder Per Facility Requirements 626 2 Surface Bolts L04161 626 2 Balanced Magnetic Switches Coordinate with Security 630 2 Concealed OH Stops C01541 630 1 Gasket ROE154 x LAR (Head & Jambs) 1 Threshold J36130
1 Removable Mullion Type 22, Keyed Blast Resistant Match Frame
Note: Perimeter gasket and Removable Mullion by door/frame manufacturer, balanced magnetic switches by Security Section 28 20 01.00 10 "ELECTRONIC
SECURITY SYSTEM".
Hardware Set 14 Door: 126A (High Security Lock w/pedestrian egress)
3 Butt Hinge A8111 NRP 4 1/2 x 4 1/2 652 1 High Security Lock FF-L-2740 (Kaba Mas X09 w/LKM 7003) 630/626 1 Closer C02011 689 1 Kickplate J102 8" x 2" LDW B4E CSK 630 1 Wall Stop L02251 630 1 Power Supply 24 VDC as Specified 1 Power Transfer Power transfer or electric hinge 652 1 Card Reader Coordinate with Security 1 Balanced Magnetic Switch Coordinate with Security Match Frame 1 Wiring Diagram With Point to Point Drawing Balance of Hardware by Door Manufacturer to provide minimum STC-45 rating 1 Gasket ROE154 x LAR (by Acoustic Door manufacturer) 1 Gasket ROE264 x LAR (by Acoustic Door manufacturer) 1 Door Bottom ROE336 (by Acoustic Door manufacturer) 1 Threshold J36130 (by Acoustic Door manufacturer)
Notes: Door, frame, hinges, gaskets, door bottom, threshold and sound seals by Acoustic Door manufacturer to provide minimum STC-45 rating. Electronic opening to operate as follows: High Security Combination Lock is unlocked with combination and dogged with a keyed bypass cylinder unlocking the deadbolt. A cardreader is then swiped to unlock an electronic mortise lock and provide access to the room. Egress from inside the space is constant at all times with operation of an ABA/ADA/NFPA compliant lever that will mechanically unlock the latch and the high security deadbolt. Note: Door, SECTION 08 71 00 Page 11 frame, gaskets, door bottom, and threshold by Acoustic Door manufacturer as required to provide an STC-45 rating. Substitutions for Balance of Hardware items are expected.
Hardware Set 15 Doors: 109A,122A (Storeroom Double Door)
6 Hinges A5111 4 1/2 x 4 1/2 NRP 652 2 Surface Bolts L04161 626 1 Storeroom Lock F07 630 1 Mortise Cylinder Per Facility Requirements 626 2 Wall Stops L02251 626 1 Threshold J36130
Hardware Set 16 Doors: 117A,119A (Storeroom Single Door)
3 Hinges A5111 4 1/2 x 4 1/2 NRP 652 1 Storeroom Lock F07 630 1 Mortise Cylinder Per Facility Requirements 626 1 Wall Stop L02251 626 1 Threshold J36130
-- End of Section --
SECTION 08 71 00 Page 12
SECTION 09 29 00
GYPSUM BOARD
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI A108.11 (1992) Interior Installation of Cementitious Backer Units
ASTM INTERNATIONAL (ASTM)
ASTM C 1002 (2007) Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs
ASTM C 1047 (2009) Standard Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base
ASTM C 1396/C 1396M (2009a) Standard Specification for Gypsum Board
ASTM C 36/C 36M (2003e1) Gypsum Wallboard
ASTM C 475/C 475M (2002; R 2007) Joint Compound and Joint Tape for Finishing Gypsum Board
ASTM C 514 (2004e1; R 2009) Standard Specification for Nails for the Application of Gypsum Board
ASTM C 840 (2008) Application and Finishing of Gypsum Board
ASTM C 954 (2007) Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from
0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness
ASTM D 226/D 226M (2009) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
SECTION 09 29 00 Page 1
GYPSUM ASSOCIATION (GA)
GA 214 (2007) Recommended Levels of Gypsum Board Finish
GA 216 (2007) Application and Finishing of Gypsum Board
GA 224 (2008) Installation of Predecorated Gypsum Board
GA 600 (2009) Fire Resistance Design Manual
UNDERWRITERS LABORATORIES (UL)
UL Fire Resistance (2009) Fire Resistance Directory
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data
Glass Mat Water-Resistant Gypsum Tile Backing Board
Deleted
Accessories
Submit for each type of gypsum board and backer units.
SD-07 Certificates
Asbestos Free Materials; G
Certify that gypsum board types, gypsum backing board types, cementitious backer units, and joint treating materials do not contain asbestos.
SD-08 Manufacturer's Instructions
Material Safety Data Sheets
SD-10 Operation and Maintenance Data
Manufacturer maintenance instructions
Waste Management
SD-11 Closeout Submittals
Local/Regional Materials; (LEED)
LEED documentation relative to local/regional materials credit in accordance with LEED Reference Guide. Include in LEED
SECTION 09 29 00 Page 2
Documentation Notebook.
Gypsum Board; (LEED)
LEED documentation relative to recycled content credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.
Adhesives; (LEED)
LEED documentation relative to low emitting materials credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.
1.3 DELIVERY, STORAGE, AND HANDLING
1.3.1 Delivery
Deliver materials in the original packages, containers, or bundles with each bearing the brand name, applicable standard designation, and name of manufacturer, or supplier.
1.3.2 Storage
Keep materials dry by storing inside a sheltered building. Where necessary to store gypsum board and cementitious backer units outside, store off the ground, properly supported on a level platform, and protected from direct exposure to rain, snow, sunlight, and other extreme weather conditions.
Provide adequate ventilation to prevent condensation. Store per manufacturer's recommendations for allowable temperature and humidity range. Do not store panels near materials that may offgas or emit harmful fumes, such as kerosene heaters, fresh paint, or adhesives.
1.3.3 Handling
Neatly stack gypsum board and cementitious backer units flat to prevent sagging or damage to the edges, ends, and surfaces.
1.4 ENVIRONMENTAL CONDITIONS
1.4.1 Temperature
Maintain a uniform temperature of not less than 50 degrees F in the structure for at least 48 hours prior to, during, and following the application of gypsum board, cementitious backer units, and joint treatment materials, or the bonding of adhesives.
1.4.2 Exposure to Weather
Protect gypsum board and cementitious backer unit products from direct exposure to rain, snow, sunlight, and other extreme weather conditions.
1.5 SUSTAINABLE DESIGN REQUIREMENTS
1.5.1 Local/Regional Materials
Use materials or products extracted, harvested, or recovered, as well as manufactured, within a 500 mile radius from the project site, if available from a minimum of three sources.
SECTION 09 29 00 Page 3
1.6 QUALIFICATIONS
Furnish type of gypsum board work specialized by the installer with a minimum of 3 years of documented successful experience.
PART 2 PRODUCTS
2.1 MATERIALS
Conform to specifications, standards and requirements specified. Provide gypsum board types, gypsum backing board types, cementitious backing units, and joint treating materials manufactured from asbestos free materials only.
2.1.1 Gypsum Board
ASTM C 36/C 36M and ASTM C 1396/C 1396M. Gypsum board shall contain a minimum of 5 percent post-consumer recycled content, or a minimum of 20 percent post-industrial recycled content.
2.1.1.1 Regular
48 inch wide, 5/8 inch thick, tapered edges.
2.1.1.2 Type X (Special Fire-Resistant)
48 inch wide, 5/8 inch thick, tapered edges.
2.1.2 Regular Water-Resistant Gypsum Backing Board
ASTM C 1396/C 1396M
2.1.2.1 Regular
48 inch wide, 5/8 inch thick, tapered edges.
2.1.3 Deleted
2.1.3.1 Deleted
2.1.3.2 Deleted
2.1.4 Joint Treatment Materials
ASTM C 475/C 475M. Use all purpose joint and texturing compound containing inert fillers and natural binders, including lime compound. Pre-mixed compounds shall be free of antifreeze, vinyl adhesives, preservatives, biocides and other slow releasing compounds.
2.1.4.1 Embedding Compound
Specifically formulated and manufactured for use in embedding tape at gypsum board joints and compatible with tape, substrate and fasteners.
2.1.4.2 Finishing or Topping Compound
Specifically formulated and manufactured for use as a finishing compound.
SECTION 09 29 00 Page 4
2.1.4.3 All-Purpose Compound
Specifically formulated and manufactured to serve as both a taping and a finishing compound and compatible with tape, substrate and fasteners.
2.1.4.4 Setting or Hardening Type Compound
Specifically formulated and manufactured for use with fiber glass mesh tape.
2.1.4.5 Joint Tape
Use cross-laminated, tapered edge, reinforced paper, or fiber glass mesh tape recommended by the manufacturer.
2.1.5 Fasteners
2.1.5.1 Nails
ASTM C 514.
2.1.5.2 Screws
ASTM C 1002, Type "G", Type "S" or Type "W" steel drill screws for fastening gypsum board to gypsum board, wood framing members and steel framing members less than 0.033 inch thick. ASTM C 954 steel drill screws for fastening gypsum board to steel framing members 0.033 to 0.112 inch thick. Provide cementitious backer unit screws with a polymer coating.
2.1.5.3 Staples
No. 16 USS gage flattened galvanized wire staples with 7/16 inch wide crown outside measurement and divergent point for base ply of two-ply gypsum board application. Use as follows:
Length of Legs (inch) Thickness of Gypsum Board (inch)
1 1/4 5/8
2.1.6 Adhesives
Do not use adhesive containing benzene, carbon tetrachloride, or trichloroethylene. Adhesive shall contain a maximum VOC content of 50 grams per liter.
2.1.6.1 Adhesive for Fastening Gypsum Board to Metal Framing
Type recommended by gypsum board manufacturer.
2.1.7 Accessories
ASTM C 1047. Fabricate from corrosion protected steel or plastic designed for intended use. Accessories manufactured with paper flanges are not acceptable. Flanges shall be free of dirt, grease, and other materials that may adversely affect bond of joint treatment. Provide prefinished or job decorated materials.
2.1.8 Asphalt Impregnated Building Felt
Provide a 15 lb asphalt moisture barrier over gypsum sheathing. Conforming
SECTION 09 29 00 Page 5 to ASTM D 226/D 226M Type 1 (No. 15) for asphalt impregnated building felt.
2.1.9 Water
Provide clean, fresh, and potable water.
PART 3 EXECUTION
3.1 EXAMINATION
3.1.1 Framing and Furring
Verify that framing and furring are securely attached and of sizes and spacing to provide a suitable substrate to receive gypsum board and cementitious backer units. Verify that all blocking, headers and supports are in place to support plumbing fixtures and to receive soap dishes, grab bars, towel racks, and similar items. Do not proceed with work until framing and furring are acceptable for application of gypsum board and cementitious backer units.
3.1.2 Gypsum Board and Framing
Verify that surfaces of gypsum board and framing to be bonded with an adhesive are free of dust, dirt, grease, and any other foreign matter. Do not proceed with work until surfaces are acceptable for application of gypsum board with adhesive.
3.1.3 Masonry Walls
Verify that surfaces of masonry walls to receive gypsum board applied with adhesive are dry, free of dust, oil, form release agents, protrusions and voids, and any other foreign matter. Do not proceed with work until surfaces are acceptable for application of gypsum board with adhesive.
3.2 APPLICATION OF GYPSUM BOARD
Apply gypsum board to framing and furring members in accordance with ASTM C 840 or GA 216 and the requirements specified. Apply gypsum board with separate panels in moderate contact; do not force in place. Stagger end joints of adjoining panels. Neatly fit abutting end and edge joints.
Use gypsum board of maximum practical length; select panel sizes to minimize waste. Cut out gypsum board to make neat, close, and tight joints around openings. In vertical application of gypsum board, provide panels in lengths required to reach full height of vertical surfaces in one continuous piece. Lay out panels to minimize waste; reuse cutoffs whenever feasible. Surfaces of gypsum board and substrate members may be bonded together with an adhesive, except where prohibited by fire rating(s).
Treat edges of cutouts for plumbing pipes, screwheads, and joints with water-resistant compound as recommended by the gypsum board manufacturer.
Provide type of gypsum board for use in each system specified herein as indicated.
3.2.1 Application of Single-Ply Gypsum Board to Wood Framing
Apply in accordance with ASTM C 840, System I or GA 216.
3.2.2 Application of Two-Ply Gypsum Board to Wood Framing
Apply in accordance with ASTM C 840, System II or GA 216.
SECTION 09 29 00 Page 6
3.2.3 Adhesive Nail-On Application to Wood Framing
Apply in accordance with ASTM C 840, System III or GA 216. This method may be used in lieu of ASTM C 840, System I at the option of the Contractor.
3.2.4 Semi-Solid Gypsum Board Partitions
Provide in accordance with ASTM C 840, System IV or GA 216 .
3.2.5 Solid Gypsum Board Partitions
Provide in accordance with ASTM C 840, System V or GA 216.
3.2.6 Adhesive Application to Interior Masonry or Concrete Walls
Apply in accordance with ASTM C 840, System VI or GA 216.
3.2.7 Application of Gypsum Board to Steel Framing and Furring
Apply in accordance with ASTM C 840, System VIII or GA 216.
3.2.8 Arches and Bending Radii
Apply gypsum board in accordance with ASTM C 840, System IX or GA 216.
3.2.9 Gypsum Board for Wall Tile or Tile Base Applied with Adhesive
In dry areas (areas other than tubs, shower enclosures, saunas, steam rooms, gang shower rooms), apply glass mat water-resistant gypsum tile backing board in accordance with ASTM C 840, System X or GA 216.
3.2.10 Exterior Application
Apply exterior gypsum board (such as at soffits) in accordance with ASTM C 840, System XI or GA 216.
3.2.11 Floating Interior Angles
Minimize framing by floating corners with single studs and drywall clips.
Locate the attachment fasteners adjacent to ceiling and wall intersections in accordance with ASTM C 840, System XII or GA 216, for single-ply and two-ply applications of gypsum board to wood framing.
3.2.12 Control Joints
Install expansion and contraction joints in ceilings and walls in accordance with ASTM C 840, System XIII or GA 216. Fill control joints between studs in fire-rated construction with firesafing insulation to match the fire-rating of construction.
3.2.13 Application of Foil-Backed Gypsum Board
Apply foil-backed gypsum board in accordance with ASTM C 840, System XIV or
GA 216.
3.2.14 Application of Predecorated Gypsum Board
Apply predecorated gypsum board in accordance with GA 224. Attach
SECTION 09 29 00 Page 7 predecorated gypsum board with adhesive and fasteners as recommended by the manufacturer. Conceal fasteners in the finished work.
3.2.15 Deleted
3.3 APPLICATION OF CEMENTITIOUS BACKER UNITS
3.3.1 Application
In wet areas (tubs, shower enclosures, saunas, steam rooms, gang shower rooms), apply cementitious backer units in accordance with ANSI A108.11.
Place a 15 lb asphalt impregnated, continuous felt paper membrane behind cementitious backer units, between backer units and studs or base layer of gypsum board. Place membrane with a minimum 6 inch overlap of sheets laid shingle style.
3.3.2 Joint Treatment
ANSI A108.11.
3.4 FINISHING OF GYPSUM BOARD
Tape and finish gypsum board in accordance with ASTM C 840, GA 214 and GA 216. Finish plenum areas above ceilings to Level 1 in accordance with GA 214. Finish water resistant gypsum backing board, ASTM C 1396/C 1396M, to receive ceramic tile to Level 2 in accordance with GA 214. Finish walls and ceilings to receive a heavy-grade wall covering or heave textured finish before painting to Level 3 in accordance with GA 214. Finish walls and ceilings without critical lighting to receive flat paints, light textures, or wall coverings to Level 4 in accordance with GA 214. Finish all gypsum board walls, partitions and ceilings to Level 5 in accordance with GA 214. Provide joint, fastener depression, and corner treatment.
Tool joints as smoothly as possible to minimize sanding and dust. Do not use fiber glass mesh tape with conventional drying type joint compounds;
use setting or hardening type compounds only. Provide treatment for water-resistant gypsum board as recommended by the gypsum board manufacturer. Protect workers, building occupants, and HVAC systems from gypsum dust.
3.4.1 Uniform Surface
Wherever gypsum board is to receive eggshell, semigloss or gloss paint finish, or where severe, up or down lighting conditions occur, finish gypsum wall surface in accordance to GA 214 Level 5. In accordance with GA 214 Level 5, apply a thin skim coat of joint compound to the entire gypsum board surface, after the two-coat joint and fastener treatment is complete and dry.
3.5 SEALING
Seal openings around pipes, fixtures, and other items projecting through gypsum board and cementitious backer units as specified in Section 07 92 00 JOINT SEALANTS Apply material with exposed surface flush with gypsum board or cementitious backer units.
3.6 FIRE-RESISTANT ASSEMBLIES
Wherever fire-rated construction is indicated, provide materials and application methods, including types and spacing of fasteners, wall and
SECTION 09 29 00 Page 8 ceiling framing in accordance with the specifications contained in UL Fire Resistance for the Design Number(s) indicated, or GA 600 for the File Number(s) indicated. Joints of fire-rated gypsum board enclosures shall be closed and sealed in accordance with UL test requirements or GA requirements. Seal penetrations through rated partitions and ceilings tight in accordance with tested systems.
3.7 PATCHING
Patch surface defects in gypsum board to a smooth, uniform appearance, ready to receive finishes.
3.8 SHAFTWALL FRAMING
Install the shaftwall system in accordance with the system manufacturer's published instructions. Coordinate bucks, anchors, blocking and other items placed in or behind shaftwall framing with electrical and mechanical work. Patch or replace fireproofing materials which are damaged or removed during shaftwall construction.
3.9 WASTE MANAGEMENT
As specified in Waste Management Plan.
Identify manufacturer's policy for collection or return of remaining construction scrap, unused material, demolition scrap, and packaging material. Institute demolition and construction recycling to take advantage of manufacturer's programs. When such a service is not available, seek local recyclers to reclaim the materials.
-- End of Section --
SECTION 09 29 00 Page 9
SECTION 28 31 64
FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ACOUSTICAL SOCIETY OF AMERICA (ASA)
ASA S3.41 (1990; R 2008) Audible Emergency Evacuation Signal (ASA 96)
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
IEEE C62.41.1 (2002; R 2008) IEEE Guide on the Surges Environment in Low-Voltage (1000 V and Less) AC Power Circuits
IEEE C62.41.2 (2002) IEEE Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and Less) AC Power Circuits
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2008; AMD 1 2008) National Electrical Code
- 2008 Edition
NFPA 72 (2010; Am 10-2; Am 10-3; Proposed Am 971) National Fire Alarm and Signaling Code
NFPA 90A (2009; Errata 09-1) Standard for the Installation of Air Conditioning and Ventilating Systems
UNDERWRITERS LABORATORIES (UL)
UL 1242 (2006; Rev thru Jul 2007) Standard for Electrical Intermediate Metal Conduit -- Steel
UL 1971 (2002; R 2004 thru 2008) Standard for Signaling Devices for the Hearing Impaired
UL 228 (2006; R 2008) Standard for Door Closers-Holders, With or Without Integral Smoke Detectors
UL 268 (2009) Smoke Detectors for Fire Alarm Signaling Systems
UL 268A (2008; R 2009) Standard for Smoke
SECTION 28 31 64 Page 1
Detectors for Duct Application
UL 38 (2008; R 2008) Standard for Manual Signaling Boxes for Fire Alarm Systems
UL 464 (2009) Standard for Audible Signal Appliances
UL 521 (1999; R 2002 thru 2005) Standard for Heat Detectors for Fire Protective Signaling Systems
UL 6 (2007) Standard for Electrical Rigid Metal Conduit-Steel
UL 797 (2007) Standard for Electrical Metallic Tubing -- Steel
UL 864 (2003; R 2003 thru 2009) Standard for Control Units and Accessories for Fire Alarm Systems
1.2 SYSTEM DESCRIPTION
The fire detection and alarm system shall be a complete, supervised fire alarm reporting system configured in accordance with NFPA 72; exceptions are acceptable as directed by the Contracting Officer. Furnish equipment compatible and UL listed, FM approved, or approved or listed by a nationally recognized testing laboratory in accordance with the applicable NFPA standards. Locks shall be keyed alike. Provide four keys for the system. Furnish tags with stamped identification number for keys and locks.
All new devices shall be connected to the new addressable fire alarm control panel. All existing devices in the unrenovated areas are to remain connected to the existing fire alarm control panel. Connect the two panels such that an alarm on one panel will initiate notification circuits on both panels.
1.2.1 Operation
Activate the system into the alarm mode by actuation of any alarm initiating device. The system will remain in the alarm mode until the initiating device is reset and the fire alarm control panel is reset and restored to normal. Alarm and supervisory initiating devices shall be individually addressable. Alarm initiating devices shall be connected to signal line circuits (SLC), Style 6, in accordance with NFPA 72. Connect alarm notification appliances to notification appliance circuits (NAC), Class A in accordance with NFPA 72. Provide a looped conduit system so that if the conduit and all conductors within are severed at any point, all IDC, NAC and SLC will remain functional. The conduit loop requirement is not applicable to the signal transmission link from the local panels (at the protected premises) to the Supervising Station (fire station, fire alarm central communication center). Textual, audible, and visual appliances and systems shall comply with NFPA 72. Fire alarm system components requiring power, except for the control panel power supply, shall operate on 24 Volts dc. The new addressable system shall be microcomputer (microprocessor or microcontroller) based with a minimum word size of eight bits and shall provide the following features:
a. Sufficient memory to perform as specified and as shown for addressable
SECTION 28 31 64 Page 2 system.
b. Individual identity of each addressable device for the following conditions: alarm; trouble; open; short; and appliances missing/failed remote detector - sensitivity adjustment from the panel for smoke detectors.
c. Capability of each addressable device being individually disabled or enabled from the panel.
d. Size each SLC to provide 40 percent addressable expansion without hardware modifications to the panel.
e. New addressable fire alarm control panel will be sized to account for new devices and future conversion of devices in the nonrenovated areas.
1.2.2 Operational Features
The system shall have the following operating features:
a. Monitor electrical supervision of IDC, SLC, and NAC.
b. Monitor electrical supervision of the primary power (ac) supply, battery voltage, placement of alarm zone module (card, PC board) within the control panel, and transmitter tripping circuit integrity.
c. A trouble buzzer and trouble LED/LCD (light emitting diode/liquid crystal diode) to…