These are contract drawings for the Gavins Point Intake Crane Replacement project by the U.S. Army Corps of Engineers, Omaha District. The detailed technical drawings comprehensively document the replacement of an 80-ton intake gantry crane, including mechanical, electrical, and structural specifications. The drawings cover multiple aspects of the new crane system, such as operator cab layout, electrical control configurations, radio control design, walkway plans, crane coverage areas, trolley layouts for main and auxiliary hoists, and detailed elevation and isometric views.
Key technical elements include a new crane with main, auxiliary, and jib hoists designed to handle intake bulkhead gates, service gates, trash rack sections, and other critical components. The project involves replacing power conductors, evaluating the existing power supply system, and potentially rehabbing the rail system. The drawings specify precise design requirements such as crane movement ranges, operator control interfaces, electrical systems, and safety features. The project is scheduled for completion 920 calendar days after contract award, with an estimated construction cost between $10-25 million, and is classified under NAICS code 238290 with a small business size standard of $45 million.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| GP104_G-201XXX Sheet 1 (1).pdf | ||
| GP104_E-201XXX Sheet 1 (1).pdf | ||
| Solicitation Amendment W9128F25RA0400005 SF 30.pdf | ||
| Solicitation Amendment W9128F25RA0400004 SF 30.pdf | ||
| Site Visit Documentation_SAM.pdf | ||
| Solicitation Amendment W9128F25RA0400003 SF 30.pdf | ||
| 41 22 13.71 26 Am-0003.pdf | ||
| 41 22 13.72 26 Am-0003.pdf | ||
| 01 35 26 Am-0003.pdf | ||
| REGISTER Am-0003.pdf | ||
| Solicitation Amendment W9128F25RA0400002 SF 30.pdf | ||
| 41 22 13.74 26 Am-0001.pdf | ||
| Solicitation Amendment W9128F25RA0400001 SF 30.pdf | ||
| 41 22 13.73 26 Am-0001.pdf | ||
| Solicitation - W9128F25RA040.pdf | ||
| W9128F25RA040 GP Intake Crane Replacement - Reference Drawings.pdf | ||
| W9128F25RA040 GP Intake Crane Replacement - Specs.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-0
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
PR
O
JE
C T
LO
C
AT
IO
N A
N D
V
IC
IN
IT
Y M
AP
S
G-001
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
OMAHA DISTRICT
GAVINS POINT DAM
MISSOURI RIVER
POWERHOUSE
INTAKE CRANE REPLACEMENT
W9128F25RA040
MAY 2025
GAVINS
POINT DAM
FLOW
TABOR
YANKTON
CH
AR
LI
E
CR.
SN
AT
C H
C R
CR.
SAN
D
BAZILE
CR.
C R
W
EI
G
AN
D BEAVER
CR.
CROFTON
LEWIS & CLARK LAKE
SPRINGFIELD
SOUTH DAKOTA
NEBRASKA
MISSOURI RIVERLEWIS & CLARK LAKE
FLOW
PICNIC
AREA 1
PICNIC
AREA 3
VISITOR
CENTER
SWIMMING AREA
RAMP
RAMP
RAMP
SWYD.
KN
O
X C
O
C
ED
AR
C
O
SOUTH SHORE
PUBLIC USE
AREA
NEBRASKA
SOUTH
DAKOTA
PICNIC
AREA 2
REST
ROOM
POWERPLANT
SPILLWAY
SHOP &
STOR. BLDG.
PROJECT
BOUNDARY
MAINT.
YARD
SANITARY
DISPOSAL STA.
LAGOON
WELL
CHANGE
HOUSE
CAMP LOOP 1
REST ROOM
CAMP LOOP 2
REST ROOM
RADIO TOWER
WELL
TOE
RD.
FISH CLEANING
FACILITY
PICNIC AREA
CREST RD.
X
X
X
XX
X
X
X X
X X
X
NORTH
SCALE: NTS
VICINITY MAPD1
Image by Google Maps, 2017
NORTH
SCALE: NTS
LOCATION MAPD7
NORTH
SCALE: NTS
SITE PLANJ14
DATE
DATE
SUBMITTED BY:
CHIEF, MECH/STRUCTURAL BRANCH
CHIEF, ELECTRICAL BRANCH
APPROVED BY:
DIRECTOR HDC
JOHN Z. YEN, P.E.
JAMES D. CALNON, P.E.
JORDAN S. FINK, P.E. DATE
THIS PROJECT WAS DESIGNED BY THE HYDROELECTRIC DESIGN CENTER OF THE U.S. ARMY CORPS OF ENGINEERS.
THE INITIALS OR SIGNATURES AND REGISTRATION DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE PROJECT
DOCUMENTS WITHIN THE SCOPE OF THEIR EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
EN
T
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-0
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
IN
D
EX
T O
D R
AW
IN
G S
G-002
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
INDEX TO DRAWINGS
GENERAL
INDEX TO DRAWINGS
TITLEFILE NAMEFILE NAMESHEET
NO. TITLE
G-001 GP104_G-001XXX.DWG PROJECT LOCATION AND VICINITY MAPS
G-002 GP104_G-002XXX.DWG INDEX TO DRAWINGS
G-003 GP104_G-003XXX.DWG INDEX TO RESOURCE DRAWINGS
G-201 GP104_G-201XXX.DWG ELEVATIONS - INTAKE CRANE
G-202 GP104_G-202XXX.DWG PLAN VIEWS - INTAKE CRANE WALKWAYS
G-401 GP104_G-401XXX.DWG CONTRACTOR STAGING AREAS
G-402 GP104_G-402XXX.DWG OPERATOR CAB LAYOUT
G-403 GP104_G-403XXX.DWG CRANE COVERAGE AREAS - EXISTING
G-901 GP104_G-901XXX.DWG ISOMETRIC VIEWS
G-902 GP104_G-902XXX.DWG EXISTING GANTRY DRIVE CLEARANCES
S-901 GP104_S-901XXX.DWG CRANE ANCHOR POINTS
M-401 GP104_M-401XXX.DWG MAIN TROLLEY LAYOUT
M-402 GP104_M-402XXX.DWG AUXILIARY TROLLEY LAYOUT
E-201 GP104_E-201XXX.DWG ELEVATION - UPSTREAM VIEW - ELECTRICAL CONTROL CABINETS
E-501 GP104_E-501XXX.DWG OPERATORS CHAIR - INSTALL
E-502 GP104_E-502XXX.DWG GANTRY CRANE RADIO CONTROL - INSTALL
E-503 GP104_E-503XXX.DWG SECONDARY OPERATOR - CONTROL STATION - INSTALL
E-601 GP104_E-601XXX.DWG ONE LINE DIAGRAM - INSTALL
STRUCTURAL
MECHANICAL
ELECTRICAL
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-0
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z, JO
R
D
AN
S . F
IN
K, P .E
IN
D
EX
T O
R
ES
O U
R C
E D
R
AW
IN
G
S
G-003
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
INDEX TO RESOURCE DRAWINGS
STRUCTURAL (USACE)
INDEX TO RESOURCE DRAWINGS
TITLEFILE NUMBERFILE NUMBER TITLE
MG51-81E7 ERECTION BAY SUBSTRUCTURE - TRANSVERSE SECTIONS - CONCRETE
MG51-81E8 ABUTMENT GRAVITY WALLS - CONCRETE AND REINFORCEMENT - SHEET 1
MG51-81E9 ABUTMENT GRAVITY WALLS - CONCRETE AND REINFORCEMENT - SHEET 2
MG51-81E19 MISCELLANEOUS STRUCTURAL - DETAILS SHEET 2
MG51-81E20 MISCELLANEOUS STRUCTURAL - DETAILS SHEET 3
MG51-81E30 INTAKE - REINFORCEMENT
MG51-81E35 ERECTION BAY SUBSTRUCTURE - WALLS REINFORCEMENT - SHEET 1
MG51-81E36 ERECTION BAY SUBSTRUCTURE - WALLS REINFORCEMENT - SHEET 2
MG51-81E37 ERECTION BAY SUBSTRUCTURE - WALLS REINFORCEMENT - SHEET 3
MG51-82E1 TRASH RACK GUIDES
MG51-82E4 BULKHEAD GATE GUIDES
838-52 JIB STRUCTURE
838-54 GANTRY STRUCTURE
838-55 GANTRY STRUCTURE
838-57 GANTRY STRUCTURE
838-101 GENERAL DRAWING
838-102 MAIN TROLLEY GENERAL DRAWING
838-103A MAIN HOIST ASSEMBLY
838-103B MAIN HOIST DETAILS
838-103C MAIN HOIST GEARCASE
838-103D MAIN HOIST GEAR CASING
838-105C MAIN TROLLEY DRIVE DETAILS
838-106A GANTRY DRIVE ASSEMBLY
838-106B IDLER TRUCK STRUCTURAL DETAIL
838-106C DRIVE TRUCK STRUCTURAL DETAIL
838-106D GANTRY DRIVE GEARCASE
838-106E GANTRY DRIVE DETAILS
838-106F GANTRY DRIVE DETAILS
838-107 UPPER SHEAVES ASSEMBLY & DETAILS
838-108A MAIN TROLLEY STRUCTURAL
838-108B MAIN HOIST TROLLEY HANDRAIL
838-109C CAB STRUCTURAL
838-109W TRASH RAKE GUIDE EXTENSION
838-109X TRASH APRON
838-110A GATE LIFTING BEAM ASSEMBLY
838-110B GATE LIFTING BEAM DETAILS
838-110C GATE LIFT BEAM STRUCTURAL
838-110D GATE LIFTING BEAM DETAILS
838-112A SPRING BUMPER ASSEMBLY
838-112B TROLLEY BUMPER - MAIN
838-113A TRASH RAKE ASSEMBLY
838-113B TRASH RAKE FOLLOWER ASSEMBLY & DETAILS
838-113C TRASH RAKE DETAILS
838-203 L.H. BRAKE DETAILS
838-203A AUX HOIST ASSEMBLY
838-203B AUX HOIST DETAILS
838-203D AUX HOIST GEARCASE
838-203E AUX HOIST GEAR CASING
838-205B AUX TROLLEY DRIVE DETAILS
838-208B MISC AUX TROLLEY STRUCTURAL
838-??? AUX TROLLEY GENERAL DRAWING
838-207 AUX UPPER SHEAVE ASSEMBLY & DETAILS
838-208A AUX TROLLEY STRUCTURAL
838-210A AUX BLOCK ASSEMBLY & DETAILS
838-210D AUXILIARY LIFT BEAM DETAILS
838-210E AUX LIFT BEAM STRUCTURAL
838-213B AUX POSITION INDICATOR DETAILS
838-302 JIB CRANE GENERAL DRAWING
838-303A JIB HOLDING LINE HOIST ASSEMBLY
838-303C L.H. LOAD BRAKE DETAILS
838-303D HOLDING LINE HOIST GEARCASE
838-304A OPERATING LINE HOIST ASSEMBLY
838-304B OPERATING LINE HOIST DETAILS
838-304C OPERATING LINE HOIST GEARCASE
838-305B JIB DRIVE DETAILS
838-51 GANTRY STRUCTURE
838-307 JIB POINT SHEAVES ASSEMBLY & DETAILS
838-308A JIB STRUCTURE ASSEMBLY
838-308B JIB STRUCTURE
838-308C JIB STRUCTURE
838-312 JIB STOP & L.S.
838-313A MAIN & AUX TR. COLLECTOR POLE
838-105A MAIN TROLLEY DRIVE ASSEMBLY
MECHANICAL (MOFFETT ENGINEERING CO.)
ELECTRICAL (RUNDEL ELECTRIC CO.)
1105-1D4 ELEMENTARY DIAGRAM FOR G.P. INTAKE GANTRY CRANE
1105-1X4 ELECTRICAL PANEL DIMENSION DRAWING
1105-2D3 CONTROL PANEL CONN. DIAGRAM
1105-3D3 CONTROL PANEL CONN. DIAGRAM & REVERSE PHASE RELAY PANEL
1105-4D3 GANTRY CONTROL PANEL CONN. DIAGRAM
1105-5D3 JIB HOIST CONTROL PANELS - CONN. DIAGRAM
1105-6D4 INTERCONNECTION DIAGRAM OF G.P. RESERVOIR INTAKE GANTRY CRANE
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
'-5
" M
IN
C
LE
AR
AN
C E
8' -1
3/
4"
22'-4" MAIN HOIST TRAVEL - SEE NOTE 7
30'-6" AUX HOIST TRAVEL - SEE NOTE 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-2
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
EL
EV
AT
IO
N
S
- I
N
TA
KE
C
R
AN
E
G-201
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
ELEVATION - DOWNSTREAM VIEWA1 SCALE: NTS
SECTION - ELEVATION A10
G-201 A10
MAIN HOIST
TROLLEY
MAIN HOIST
LIFTING BEAM
SEE NOTE 4
AUX HOIST
TROLLEY
AUX HOIST
LIFTING BEAM
OPERATOR
CAB
AU
X
H O
IS
T
M
IN
LI
FT
H
EI
G H
T
5' -2
SE
E N
O
TE
3 M
AI
N H
O
IS
T M
IN
LI
FT
H
EI
G
H T
'-0
SE
E N
O
TE
REMOVEABLE
MACHINERY
HOUSING
REMOVEABLE
MACHINERY
HOUSING
REMOVEABLE
MACHINERY
HOUSING
REMOVEABLE
MACHINERY
HOUSING
JIB HOIST
JIB HOIST
WALKWAY
WALKWAY
WALKWAY
NOT SHOWN
FOR CLARITY
WALKWAY
NOT SHOWN
FOR CLARITY
WALKWAY
WALKWAY
INTAKE GATE
HYDRAULIC CYLINDER
ASSEMBLY, TYP
30'-0"
TRASH RACK
GUIDES
OPERATOR CAB
ANEMOMETER
ANEMOMETER
20'-0" INTAKE
GATE WIDTH
18'-9" TRASH RACK WIDTH
11'-8"
14'-6"
INTAKE GATE
INTAKE CYLINDAR
HYDRAULIC
MACHINERY COVER
COLLECTOR
BUS BAR
30'-3"
FLOW
REMOVEABLE JIB HOIST
MACHINERY HOUSING
BUMPER
GRAPPLE
INTAKE GATE
HYDRAULIC
CYLINDER
ASSEMBLY, TYP
INTAKE GATE
TRASH RACK
EL 1234.0
EL 1262.0
POWERHOUSE
WALL
1. THIS DRAWING SHOWS CONCEPTUAL DESIGN FOR THE NEW CRANE. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE A COMPLETE DESIGN
THAT MEETS THE COMPLETE REQUIREMENTS OF THE CONTRACT.
2. SEE SHEETS G-403 FOR LIFTING HOOK COVERAGE.
3. SEE SPECIFICATION SECTION 41 22 13.71 26 FOR LIMITS OF HOOK ELEVATIONS.
ENSURE THAT THE NEW CRANE'S HOIST LIMITS AS DEPICTED AND DETAILED IN
THE SPECIFICATIONS ARE SUFFICIENT TO PERFORM GATE, BULKHEAD,
CYLINDER, AND TRASH RACK PLACEMENT, REMOVAL, AND POSITIONING.
4. MAIN HOIST LIFTING BEAM MUST CLEAR AUX HOIST TROLLEY HOUSE.
5. THERE IS VERY LIMITED CLEARANCE AT THE INTAKE DECK BETWEEN EXISTING
STRUCTURES/EQUIPMENT AND THE NEW GANTRY DRIVE MACHINERY. SEE
SHEET G-902 FOR PICTURES OF EXISTING CLEARANCES.
6. AIRCRAFT WARNING LIGHTS ARE REQUIRED TO BE INSTALLED AND MOUNTED
ON EACH OF THE FOUR CORNERS OF THE CRANE, AT THE HIGHEST POINTS
FEASIBLE.
7. UPSTREAM AND DOWNSTREAM LIMITS OF THE MAIN AND AUXILIARY HOISTS
MUST BE IDENTICAL TO THE EXISTING HOIST ARRANGEMENT. SEE
REFERENCE DRAWINGS FOR DETAILS.
8. INCLUDE PLEXIGLASS OR SEE-THROUGH PORTION OF CAB ROOF ON THE
SOUTH SIDE OF THE CAB TO IMPROVE LINE OF SIGHT VISIBILITY TO THE MAIN
HOIST HOOKS AT THEIR HIGHEST POSITION.
9. GUARDRAILS ON THE WALKWAY BETWEEN THE TWO UPPER TRASH RACK
ACCESS PLATFORMS MUST BE REMOVABLE. SEE CONTRACT SPECIFICATIONS
FOR DETAILS
10. CONTRACTOR TO VERIFY EXISTING TRASH RACK GUIDE DIMENSIONS AND
SLOPE TO ENSURE THAT THE NEW CRANE'S TRASH RACK GUIDES WILL
INTERFACE PROPERLY WITH THE EXISTING TRASH RACKS AND GUIDES.
11. ENSURE THERE IS A MINIMUM OF 6 INCHES OF CLEARANCE BETWEEN THE
TOP OF THE AUXILIARY HOIST TROLLEY AND THE LOWEST POINT OF THE MAIN
LIFTING BEAM ASSEMBLY.
GENERAL NOTES
POWERHOUSE
WALL
JIB HOIST
HOLDING LINE
ASSEMBLY
JIB HOIST
SLEW DRIVE
GEARMOTOR
MANUAL CRANE
TIE OFF ANCHOR
POINTS. SEE S-901
CL OF RAIL CL OF RAIL
TRASH RACK
GUIDES. SEE
NOTE 10
4'-6 3/4" 10'-2" 15'-6"
IR HEATERS
IR HEATER
IR HEATER
REMOVEABLE JIB HOIST
MACHINERY HOUSING
STAIRSSTAIRS
STAIRS
UPPER TRASH RACK
ACCESS PLATFORM
WALKWAY (GUARDRAILS
HIDDEN FOR CLARITY)
SEE NOTE 9
SWING GATE
TO LADDER
SEE NOTE 8
3" MIN CLEARANCE
'-5
/2
" M
IN
C
LE
AR
AN
C E
E-201 A1
ADD PERSONNEL TIE
DOWN BOTH SIDES
1'-6 3/4"
2'-1"
RIGGING ENCLOSURE
2X STORM
BRAKES
G-402 H1
G-902 A8
SEE NOTE 5
INTAKE GATE SLOT
ROADWAY BARRIER
BULKHEAD SLOT
G-902
H6
SEE NOTE 5
INTAKE DECK
GUARDRAILS
G-201 A1
G-202 K1
G-202 A1
G-202 A10
1" C
LR
M
IN
6'-3 1/2"
CONTRACTOR
TO FIELD
VERIFY
9" C
LE
AR
AN
C
E M
IN
2' -6
" M
IN
6" M
IN
C
LE
AR
AN
C
E.
SE
E N
O
TE
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
EN
T
26'-4"
TRASH RACK
LADDER
ACCESS
OPENING
LADDER
ACCESS
OPENING
UP
UP DOWN
DOWN
DOWN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-2
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
PL
AN
V
IE
W
S
- I
N
TA
KE
C
R
AN
E W
AL
KW
AY
S
G-202
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: 1/4"=1'-0"
PLAN - AUX HOIST LEVEL WALKWAYSA1 SCALE: 1/4"=1'-0"
PLAN - MAIN HOIST LEVEL WALKWAYSA10
1. ELECTRICAL AND CONTROLS CABINETS MUST BE CAPABLE OF OPENING
150 DEGREES. CLEARANCES IN FRONT OF ELECTRICAL AND CONTROLS
CABINETS MUST BE KEPT AT A MIN OF 36 INCHES. SEE SPECIFICATIONS
FOR ADDITIONAL REQUIREMENTS.
GENERAL NOTES
G-201 A10
FLOW
SCALE: 3/8"=1'-0"
PLAN - OPERATOR CAB LEVEL WALKWAY (SOUTH SIDE)K1
G-201 A10
G-201 A10
ACCESS TO TRASH RACK
UPPER POSITIONING
PLATFORM
STAIRS TO OPERATOR CAB
LEVEL WALKWAY
STAIRS TO MAIN HOIST
LEVEL WALKWAY
ELECTRICAL CABINETS
AUXILIARY HOIST
TROLLEY
STAIRS TO OPERATOR CAB
LEVEL WALKWAY (SOUTH SIDE)
STAIRS TO AUX HOIST
LEVEL WALKWAY
JIB HOIST
STRUCTURAL
SUPPORT
STAIRS TO AUX HOIST
LEVEL WALKWAY
MAIN HOIST
TROLLEY
JIB HOIST
MACHINERY
HOUSING
ACCESS TO INTAKE DECK
2'-0" MIN
3' -0
C
LE
AR
AN
C
E M
IN
2'-0" MIN U
.S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
EN
T
PLAN
NORTH
4'0 2' 8'
FLOW
FLOW
0 4' 8'2' 0 4' 8'2'
PLAN
NORTH
PLAN
NORTH
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-4
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
C
O N
TR
AC
TO
R
S
TA
G
IN
G A
R
EA
S
G-401
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
Image by Google Maps, 2021CONTRACTOR STAGING AREA
SCALE: NTS
CONTRACTOR STAGING AREASA1
GENERAL NOTES:
1. INDICATES CONTRACTORS STAGING AREAS.
2. STAGING AREA BY OVERHEAD HIGH VOLTAGE POWER LINES THAT WILL
RESTRICT ABILITY TO USE MOBILE CRANE FOR EQUIPMENT HANDLING.
3. CREST ROAD IS A PUBLIC ROAD. COORDINATE WITH THE GOVERNMENT TO
CLOSE PUBLIC ACCESS.
ADMINISTRATIVE BUILDING
POWERHOUSE ACCESS ROAD
SECURITY GATE
POWERHOUSE ENTRANCE
POWERHOUSEINTAKE DECK
PUBLIC ROAD
ERECT NEW CRANE IN THIS AREA BLUFF
EXISTING INTAKE CRANE
NORTH
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
UP2'-6"
2' -6
C
LE
AR
AN
C
E
SWING GATE
GUARD RAIL
7" C
LE
AR
AN
C
E
OPERATOR CAB WALKWAY
OPERATOR CAB
4'-8" MIN
UPSTREAM
MAIN
HOIST
LOWER
RAISE
UPSTREAM
TROLLEY
UPSTREAM
AUX HOIST
LOWER
RAISE
BRAKE
FAULT
ON
START
STOP
LOWER DOWNSTREAM LOWER
RAISE UPSTREAM RAISE
BRIDGE
EMERGENCY
STOP
DOWNSTREAM
MAIN
HOIST
LAND
SIDE
DOWNSTREAM
TROLLEY
RIVER
SIDE
HORN
TANDEM
CONTROL SLOW
TANDEM
CONTROL
FLOOD
LIGHTS
ONOFF
EMERGENCY STOP & CRANE STOP
PUSHBUTTONS MUST NOT BE
OPERATED DURING A BRAKE FAULT
NORM
FAST
OFF ON
DOWNSTREAM
AUX HOIST
EMERGENCY
STOP
RADIO
CONTROL
RADIO
CONTROL
ONOFF
UPSTREAM
DOWNSTREAM
DOWNSTREAM DOOR
FIRE
EXTINGUISHER
STAIRS TO AUX
HOIST
OPERATOR CHAIR
ABLE TO ROTATE
270° AND SERVICE
NORTH AND SOUTH
SIDES OF CRANE.
3' -0
" M
IN
LADDER
LADDER/
PLATFORM
OPENING
FLOOR WINDOW, TYP
CRANE
LEG
SECONDARY OPERATOR
CONTROL CENTER
BRIDGE
LAND
SIDE
RIVER
SIDE
SLOW
ONOFF
FAST
OFF ON
SLOW
ONOFF
FAST
OFF ON
LOWER DOWNSTREAM LOWER
RAISE UPSTREAM RAISE
DOWNSTREAM
MAIN
HOIST
DOWNSTREAM
TROLLEY
DOWNSTREAM
AUX HOIST
SLOW FASTSLOW FAST
LADDER
ACCESS
OPENING
BOTTOM OPERABLE CASEMENT
WINDOWS ALONG LENGTH OF CAB TO
AID COMMUNICATION WITH RIGGERS
HEAT PUMP
UNIT
8' -0
" M
IN
IM
U
M
5'-0"
20'-0" MAXIMUM
3' -0
" M
IN
IM
U
M
GUARD RAILS
REMOVED FOR
CLARITY
1'-4" MINIMUM 3'
-6
" T
YP
OPERATOR CAB
CRANE LEG
IR HEATER
9'-0"
IR HEATER
WINDOW, TYP
~HVAC
11'-0" MIN
OPERATOR CAB
CRANE LEG
LADDER
STAIRWELL
IR HEATER
WINDOW, TYP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-4
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
O
PE
R
AT
O
R C
AB
L
AY
O
U T
G-402
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
ELEVATION - OPERATOR CABA1
GENERAL NOTES:
1. THIS DRAWING SHOWS A CONCEPTUAL DESIGN FOR THE NEW CRANE. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE A COMPLETE DESIGN
THAT MEETS THE COMPLETE REQUIREMENTS OF THE CONTRACT.
2. SECONDARY OPERATOR CONTROL STATION MAY CONTROL THE CRANE VIA
SELECTOR SWITCH LOCATED ON OPERATOR CONTROL CHAIR. SECONDARY
OPERATOR CONTROL STATION IS INTENDED FOR OPERATOR USE DURING
PRECISION LIFTS UTILIZING THE MAIN AND AUXILIARY HOISTS.
3. OPERATOR CONTROL CHAIR TO BE MOUNTED ON SLIDING TRACKS THAT
ALLOW THE CHAIR TO MOVE NORTH AND SOUTH WITHIN THE CAB, THE ENTIRE
DISTANCE FROM WINDOW TO WINDOW.
SCALE: NTS
END VIEW - CAB A14
SCALE: NTS
PLAN - OPERATOR CABH1
NOTE: CAB ROOF REMOVED FOR CLARITY
FLOW
FLOW
G-402 G1
A1 G-402
G-402 A1
A14 G-402
G-201 A10
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
EN
T
AUX HOIST
COVERAGE AREAMAIN HOIST COVERAGE AREA
JIB HOIST COVERAGE AREA
INTAKE GATE
HYDRAULIC CYLINDER (x9)
INTAKE GATE
HYDRAULIC CYLINDER
CONTROL STATION (x3)
INTAKE GATE SLOT (x9)NEW INTAKE CRANE INTAKE BULKHEAD SLOT (x9)MOVEABLE CONCRETE
JERSEY BARRIERS
DECK HATCH
CL INTAKE
CRANE
RAILS
CL INTAKE
CRANE
RAILS
JIB HOIST
TRASH RACK SLOT (X9)
18'-9" AUX HOIST
'-6
" A U
X H
O
IS
T
'-4
" M
AI
N H
O
IS
T 3'
-5
1/
3' -4
31'-0"
'-0
" R
EF
3' -1
0"
295'-1"
GATE REPAIR PIT
R28 '-0
(300'-11")
18'-1"
AUX HOIST
16'-1"
MAIN HOIST
15'-0"
AUX HOIST
17'-10"
MAIN HOIST
2' -1
1' -6
/4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-4
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
C
R
AN
E C
O
VE
R
AG
E
AR
EA
EX
IS
TI
N
G
G-403
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
CRANE COVERAGE AREASA1
GENERAL NOTES:
1. ALL DIMENSIONS TO BE FIELD VERIFIED BY CONTRACTOR.
2. NOMINAL DIMENSIONS ARE SHOWN BASED ON THE GEOMETRY OF THE
CONCEPTUAL DESIGN AND DRAWINGS OF THE ORIGINAL CRANE AND
POWERHOUSE. FINAL DESIGN OF THE NEW CRANE BUT THE COVERAGES
LISTED MUST BE MET OR EXCEEDED FOR EACH HOIST AND EACH HOIST MUST
BE CAPABLE OF PICKING AND PLACING COMPONENTS (INTAKE GATES,
BULKHEADS, CYLINDERS, TRASH RACKS, ETC.) AS REQUIRED FOR
POWERHOUSE OPERATIONS.
LEGEND
JIB HOIST COVERAGE AREA (CENTERLINE OF HOIST)
AUX HOIST COVERAGE AREA (CENTERLINE OF HOIST)
MAIN HOIST COVERAGE AREA (CENTERLINE OF HOIST)
PLAN
NORTH
FL
O
W
1' -9
1/
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-9
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
IS
O M
ET
R
IC
V
IE
W
S
G-901
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
ISOMETRIC - DOWNSTREAM VIEWB1
GENERAL NOTES:
1. AS REQUIRED BY ALL SPECIFICATION, ALL HOUSING ROOFS MUST BE SLOPED.
2. SEPARATE STAIR HAND AND GUARD RAILS ARE NOT SHOWN BUT ARE
REQUIRED PER EM385-1-1 AND OSHA.
3. FALL ARREST TIE-OFF POINTS REQUIRED ON THE INBOARD SIDE OF EACH
CRANE LEG 76" ABOVE DECK LEVEL.
4. MOUNT ANEMOMETER TO THE NORTH UPSTREAM CORNER OF THE JIB HOIST
MACHINERY HOUSING. DISPLAY TO BE MOUNTED ON ELECTRICAL CABINET.
SEE SPECIFICATION 41 22 13.74 26 PARAGRAPH 2.5.2 FOR DETAILS.
5. DESIGN TROLLEY ACCESS SUCH THAT THE INBOARD GUARDRAILS ON THE
LAND SIDE AND RIVER SIDE FOR THE AUX TROLLEY AND THE LAND SIDE FOR
THE MAIN TROLLEY MAY SERVE AS DUAL PURPOSE GUARD RAILS AND LADDER
RUNGS FOR ACCESS TO MAIN AND AUXILIARY HOIST TROLLEYS. PROVIDE
FALL PROTECTION AND OTHER ACCESS DESIGN AS REQUIRED.
SCALE: NTS
ISOMETRIC - UPSTREAM VIEWA10
FLOW
FLOW
MAIN HOIST TROLLEY
ELECTRICAL
CONTROL
CABINETS
WALKWAY (TYP)
AUXILIARY HOIST TROLLEY
JIB HOIST
MACHINERY HOUSING
OPERATOR CAB
GRAPPLE
GRAPPLE
JIB HOIST
OPERATOR CAB
JIB HOIST
MACHINERY HOUSING
TRASH RACK GUIDES
AUXILIARY
HOIST
TROLLEY
AUXILIARY TROLLEY RAILS
AND END STOP (TYP)
MAIN HOIST TROLLEY
ANEMOMETER
SEE NOTE 4
OPERABLE WINDOWS ON
THIS SIDE OF CAB TO AID
COMMUNICATION WITH
RIGGERS
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
EN
T
2X RIGGING CABINET
2X STORM BRAKE
INBOARD LANDSIDE AND RIVERSIDE
WALKWAY GUARDRAILS. SEE NOTE 5
MAIN TROLLEY RAILS
AND END STOP (TYP)
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_G
-9
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
G
AN
TR
Y C
R
AN
E C
LE
AR
AN
C
ES
G-902
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
PHOTO - GANTRY CRANE CLEARANCES DOWNSTREAMA8
GENERAL NOTES:
1. CONTRACTOR TO FIELD-VERIFY CLEARANCES AROUND EXISTING CRANE'S
GANTRY DRIVE EQUIPMENT FOR USE IN DESIGNING THE NEW CRANE'S
GANTRY DRIVE EQUIPMENT AND STORM BRAKE PLACEMENT.
SCALE: NTS
PHOTOS - GANTRY CRANE CLEARANCE. UPSTREAM SIDEH6
G-201 A10
G-201 A10
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_S
-9
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
T.
M
C G
IL
VR
EY
, P
.E
JO
R
D
AN
S . F
IN
K, P .E
C
R
AN
E
AN
C H
O R
P O
IN
TS
S-901
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
DOWNSTREAM ANCHOR POINTS (UPSTREAM SIMILAR)A1
GENERAL NOTES:
1. CRANE ANCHOR POINTS LOCATED ON EACH LEG OF CRANE.
2. NEW GANTRY CRANE ANCHOR POINTS MUST BE COMPATIBLE WITH THE
EXISTING ANCHOR POINTS AND ANCHORING MECHANISM SHOWN.
SCALE: NTS
DOWNSTREAM ANCHOR POINTS (UPSTREAM SIMILAR)A10
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
1 TON BRIDGE CRANE STYLE
MAINTENANCE HOIST
CL OF
WHEELS
CL OF
WHEELS
MAIN HOIST
UPPER BLOCK
X2
HOIST BRAKES
HOIST GEARBOX
HOIST MOTOR
TROLLEY DRIVE
GEARBOX
TROLLEY DRIVE
MOTOR
TROLLEY DRIVE
BRAKE
HOIST DRUM
HOIST DRUM
OPENINGS IN
TROLLEY FLOOR.
SEE NOTE 5
HOIST MOTOR
HOIST BRAKES
HOIST GEARBOX
TROLLEY DRIVE
GEAR BOX
MAINTENANCE HOIST
ACCESS HATCH
ENTRY
DOOR
1 TON BRIDGE CRANE
STYLE TOOL HOIST
MAIN HOIST
UPPER BLOCK, X2
TROLLEY DRIVE MOTOR
TROLLEY DRIVE BRAKE
3' -0
4'-6"
DRUM BEARING
PEDESTAL
HOIST DRUM
BEARING
MAINTENANCE HOIST
MINIMUM COVERAGE AREA
SEE NOTE 7
2X ACCESS HATCH
TIE OFF POINT
SEE NOTE 6
ENTRY DOOR
6' -0
" M
IN 7'
-0
" M
IN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_M
-4
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
M
AI
N
T R
O
LL
EY
L
AY
O
U T
M-401
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
ELEVATION - MAIN HOIST TROLLEYA1
GENERAL NOTES:
1. THIS DRAWING SHOWS A CONCEPTUAL DESIGN FOR THE NEW CRANE'S MAIN
HOIST. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE A
COMPLETE DESIGN THAT MEETS THE COMPLETE REQUIREMENTS OF THE
CONTRACT.
2. CMAA 70 STYLE A1 TROLLEY DRIVE IS DEPICTED HERE. SEE CONTRACT
SPECIFICATIONS FOR DRIVE ARRANGEMENT DETAILS.
3. SEE SPECIFICATIONS FOR HOIST DRUM TO SPEED REDUCER CONNECTIONS.
4. LOCATE ACCESS GATES IN THE WALKWAY GUARD RAILS SUCH THAT THEY
ALIGN WITH THE TROLLEY ENTRY DOOR WHEN THE TROLLEY IS POSITIONED
AT EITHER END OF THE TROLLEY TRACKS AGAINST THE TROLLEY END STOPS.
5. MINIMIZE OPENINGS FOR WIRE ROPE AS MUCH AS POSSIBLE. PROVIDE MEANS
TO EXCLUDE BIRDS AND OTHER ANIMALS.
6. PROVIDE TIE OFF POINTS FOR FALL PROTECTION NEAR THE MAINTENANCE
HOIST HATCH THAT COMPLY WITH CONTRACT SPECIFICATIONS AND
APPLICABLE SAFETY CODES AND GUIDANCES.
7. MAINTENANCE HOIST MUST BE CAPABLE OF ACCESSING HOIST BRAKES, HOIST
MOTOR, TROLLEY BRAKES, TROLLEY MOTORS, AND THE MAINTENANCE HOIST
ACCESS HATCH.
SCALE: NTS
END VIEW - MAIN HOIST TROLLEYA10
SCALE: NTS
PLAN - MAIN HOIST TROLLEYG1
FLOW
FL
O
W
M-401 G1
A1 M-401
M-401 A1
A10 M-401
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
EN
T
ENTRY DOOR
7' -0
" M
IN
6' -0
" M
IN
HOIST MOTORHOIST BRAKE
HOIST GEARCASE
HOIST DRUM
MAINTENANCE HOIST
ACCESS HATCH
ENTRY
DOOR
AUXILIARY HOIST
UPPER BLOCK
X2
ENTRY
DOOR
DRUM PEDESTAL
4'-6"
3'
OPENINGS IN
TROLLEY FLOOR.
SEE NOTE 5
TIE OFF POINT
2X ACCESS HATCH TIE OFF
POINT - SEE NOTE 6
MAINTENANCE HOIST
MINIMUM COVERAGE AREA
SEE NOTE 7
1 TON BRIDGE CRANE
MAINTENANCE HOIST
CL OF
WHEELS CL OF
WHEELS
HOIST DRUM
HOIST GEARCASE
HOIST BRAKE
AUXILIARY HOIST
UPPER BLOCK
X2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_M
-4
XX
X.
dw g
S.
H
IN
N
EN
, P
.E
P.
H
AR
PO
LE
S.
H
EI
N
Z
JO
R
D
AN
S . F
IN
K, P .E
AU
XI
LI
AR
Y
H O
IS
T
TR
O
LL
EY
L
AY
O U
T
M-402
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SCALE: NTS
PLAN - AUXILIARY HOIST TROLLEYA1
GENERAL NOTES:
1. THIS DRAWING SHOWS A CONCEPTUAL DESIGN FOR THE NEW CRANE'S
AUXILIARY HOIST TROLLEY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR
TO PROVIDE A COMPLETE DESIGN THAT MEETSTHE COMPLETE
REQUIREMENTS OF THE CONTRACT.
2. THE CONTRACTOR IS RESPONSIBLE FOR DESIGNING THE AUX HOIST TROLLEY
DRIVE SYSTEM SUCH THAT IT IS SUITABLE FOR SIDE LOADING INDUCED BY
PICKING AND PLACING THE TRASH RACKS. SEE SPECIFICATIONS FOR AUX
HOIST TROLLEY DRIVE DETAILS.
3. CONCEPTUAL DESIGN SHOWS ONE METHOD FOR DRUM TO SPEED REDUCER
CONNECTION. SEE SPECS FOR ALTERNATE ALLOWABLE METHODS.
4. LOCATE ACCESS GATES IN THE WALKWAY GUARD RAILS SUCH THAT THEY
ALIGN WITH THE TROLLEY ENTRY DOOR WHEN THE TROLLEY IS POSITIONED
AT EITHER END OF THE TROLLEY TRACKS AGAINST THE TROLLEY END STOPS.
5. MINIMIZE OPENINGS FOR WIRE ROPE AS MUCH AS POSSIBLE. PROVIDE MEANS
TO EXCLUDE BIRDS AND OTHER ANIMALS.
6. PROVIDE TIE OFF POINTS FOR FALL PROTECTION NEAR THE MAINTENANCE
HOIST HATCH THAT COMPLY WITH CONTRACT SPECIFICATIONS AND
APPLICABLE SAFETY CODES AND GUIDANCES.
7. MAINTENANCE HOIST MUST BE CAPABLE OF ACCESSING HOIST BRAKES, HOIST
MOTOR, TROLLEY BRAKES, TROLLEY MOTORS, AND THE MAINTENANCE HOIST
ACCESS HATCH.
SCALE: NTS
PLAN - AUXILIARY HOIST TROLLEYG1
SCALE: NTS
END VIEW - AUXILIARY HOIST TROLLEY A11
FLOW
FL
O
W A1 M-402
M-402 G1
M-402 A1
A11 M-402
NOTE: AUXILIARY TROLLEY DRIVE MACHINERY OMITTED FOR CLARITY. SEE NOTE 2
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
EN
T
3'-6" TYP
2'-0" TYP
2' -0
" T
YP
6' -0
" T
YP
16'-6" (ELECTRICAL CONTROL CABINETS)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_E
-2
XX
X.
dw g
D . T
R O
W
BR
ID
G
E, P
.E
P.
H
AR
PO
LE
E.
J
AC
KS
O N
, P .E
JO
R
D
AN
S . F
IN
K, P .E
EL
EV
AT
IO
N
EL
EC
TR
IC
AL
C O
N
TR
O L
C
AB
IN
ET
S
E-201
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
GENERAL NOTES:
1. THIS DRAWING SHOWS CONCEPTUAL DESIGN FOR THE NEW CRANE. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE A COMPLETE DESIGN
THAT MEETS THE COMPLETE REQUIREMENTS OF THE CONTRACT.
2. ELECTRICAL CABINETS AND RESISTOR BANKS TO BE MOUNTED ON SILL BEAM
AS SHOWN. CABINETS MUST INCLUDE 480V DISTRIBUTION EQUIPMENT, VFDS,
AND CONTROL CIRCUITRY. ALL ELECTRICAL DISTRIBUTION EQUIPMENT IS
EXPECTED TO RESIDE WITHIN OR NEAR THE ELECTRICAL CONTROL CABINETS
AS SHOWN.
3. SOME PARTS OF CRANE AND DECK NOT SHOWN FOR CLARITY.
SCALE: NTS
ELEVATION - ELECTRICAL CONTROL CABINETSA1G-201
A1
SILL BEAM
STAIRS NOT
SHOWN FOR
CLARITY
GUARD RAILS
NOT SHOWN
FOR CLARITY
FLOW
TRASH RACK
GUIDES
TRASH RACK LOWER
POSITIONING PLATFORM
INTAKE DECK GUARD RAIL
TRASH RACK UPPER
POSITIONING PLATFORM
EL 1234.0 BULKHEAD SLOT
ROADWAY BARRIER
INTAKE GATE HYDRAULIC
CYLINDER ASSEMBLY, TYP
INTAKE CYLINDER HYDRAULIC
MACHINERY COVER
COLLECTOR BUS BAR
1" C
LR
M
IN
4" C
LR
M
IN
GUARD RAILS
NOT SHOWN
FOR CLARITY
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
MAIN HOIST
HORN
RADIO ON
LAMP
CRANE ON
LAMP
START STOP
LOWER
RAISE
SPEED
NORMAL
FASTSLOW
EMERGENCY
STOP
AUX HOIST
BRAKE FAILURE
HIGH LOAD
WARNING(1
'-8
(1'-3")
GANTRY
NORTH
FLOODLIGHTS
ONOFF
GANTRY
SOUTH
TROLLEY
D.S.
TROLLEY
U.S.
AUX
HOIST JIB HOIST
LOWER
RAISE
JIB SLEW
CLOCKWISELOWER
RAISE COUNTER
CLOCKWISE
ALARM
SILENCE
TROLLEY
SELECTOR
AUXMAIN
IR HEATERS
ONOFF
HOIST
OVERLOAD
JIB HOIST
BRAKE FAILURE
MAIN HOIST
BRAKE FAILURE
JIB HOIST
OPEN
JIB HOIST
CLOSE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_E
-5
XX
X.
dw g
D . T
R O
W
BR
ID
G
E, P
.E
P.
H
AR
PO
LE
E.
J
AC
KS
O N
, P .E
JO
R
D
AN
F
IN
K, P
.E
IN
ST
AL
L
O
PE
R
AT
O R
S C
H
AI
R
E-501
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
GENERAL NOTES:
SCALE: NTS
OPERATORS CHAIRA1
SINGLE AXIS MASTER SWITCH
1. FOR CLARITY, NOT ALL COMPONENTS ARE SHOWN.
2. REFER TO ADDITIONAL SPECIFICATIONS IN SECTION
41 22 13.74 26.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS
AND CONDITIONS.
4. DRAWING IS CONCEPTUAL. OMISSION OF
COMPONENTS FROM THIS DRAWING SHALL NOT BE
CONSTRUED AS PERMITTING DEVIATIONS FROM
CODE OR FROM THE SPECIFICATIONS.
5. CONTRACTOR SHALL DESIGN AND SUBMIT FOR
APPROVAL IN ACCORDANCE WITH SPECIFICATION
SECTIONS 26 05 00.01 26 AND 41 22 13.74 26.
LEGEND:
MAIN HOIST
MASTER SWITCH
JIB HOIST
BRAKE FAILURE
LAMP
AUX HOIST
BRAKE FAILURE
LAMP
RADIO ON LAMP
CRANE ON LAMP
START
STOP
HOIST
OVERLOAD
WARNING
LAMP
HORN
EMERGENCY
STOP
FLOODLIGHTS
ON/OFF
HOIST SPEED
SELECTOR
INDICATION LIGHT
MOMENTARY PUSH BUTTON
E-STOP BUTTON
(MAINTAINED, PUSH-PULL, TWIST TO RELEASE)
MAINTAINED SELECTOR SWITCH
GANTRY
MASTER SWITCH
TROLLEY
MASTER SWITCH
AUX HOIST
MASTER SWITCH
JIB HOIST
MASTER SWITCH
JIB SLEW
MASTER SWITCH
ALARM
SILENCE
TROLLEY
SELECTOR
IR HEATERS
MAIN HOIST
BRAKE FAILURE
LAMP
HIGH LOAD
WARNING LAMP
JIB CLAM SHELL
MASTER SWITCH
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_E
-5
XX
X.
dw g
D . T
R O
W
BR
ID
G
E, P
.E
P.
H
AR
PO
LE
E.
J
AC
KS
O N
, P .E
JO
R
D
AN
F
IN
K, P
.E
IN
ST
AL
L
G
AN
TR
Y
C R
AN
E
R
AD
IO
C
O N
TR
O
L
E-502
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
GENERAL NOTES:
SCALE: NTS
GANTRY CRANE RADIO CONTROLA1
1. DRAWING IS CONCEPTUAL. OMISSION OF COMPONENTS FROM
THIS DRAWING SHALL NOT BE CONSTRUED AS PERMITTING
DEVIATIONS FROM CODE OR FROM THE SPECIFICATIONS.
ALTERNATE CONFIGURATIONS ARE SUBJECT TO APPROVAL.
2. CONTRACTOR SHALL DESIGN AND SUBMIT FOR APPROVAL IN
ACCORDANCE WITH SPECIFICATION SECTIONS 26 05 00.01 26
AND 41 22 13.74 26.
MAIN HOIST: XX.X TONS MAIN HOIST: XXX.X FT
AUX HOIST: XX.X TONS AUX HOIST: XXX.X FT
JIB HOIST: XX.X TONS JIB HOIST: XXX.X FT
FAULT ANNUNCIATION
HORN
HOIST SPEED
NORMAL
SLOW FAST
GANTRY
NORTH/RIVER
GANTRY
SOUTH/LAND
TROLLEY
UPSTREAM
TROLLEY
DOWNSTREAM
MAIN
HOIST
LOWER
MAIN
HOIST
RAISE
ON/OFF
FLOODLIGHTS
OFF ON
TRANSMITTER
ON/OFF SWITCH
DIGITAL DISPLAY
TRAVEL ALARM
SILENCE SWITCH
JIB
HOIST
LOWER
JIB
HOIST
RAISE
JIB
SLEW
CW
JIB
SLEW
CCW
AUX
HOIST
LOWER
AUX
HOIST
RAISE
IR HEATERS
OFF ON
TROLLEY
SELECTOR
MAIN AUX
JIB OP.
OPEN
JIB OP.
CLOSE
NOTE: QTY 2 (1-SPARE)
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
MAIN HOISTHORN
RADIO ON
LAMP
CRANE ON
LAMP
START STOP
LOWER
RAISE
SPEED
NORMAL
FASTSLOW
EMERGENCY
STOP
MAIN HOIST
BRAKE FAILURE
AUX HOIST
BRAKE FAILURE
(1 '-0
(2'-0")
GANTRY
NORTH
FLOODLIGHTS
ONOFF
GANTRY
SOUTH
TROLLEY
D.S.
TROLLEY
U.S.
AUX
HOIST
LOWER
RAISE
ALARM
SILENCE
IR HEATERS
ONOFF
HOIST
OVERLOAD
HIGH LOAD
WARNING
TROLLEY
SELECTOR
AUXMAIN
OP. SOURCE
STATION
RADIOCAB
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_E
-5
XX
X.
dw g
D . T
R O
W
BR
ID
G
E, P
.E
P.
H
AR
PO
LE
E.
J
AC
KS
O N
, P .E
JO
R
D
AN
F
IN
K, P
.E
IN
ST
AL
L
C O
N
TR
O L
ST
AT
IO
N
SE
C
O N
D
AR
Y O
PE
R
AT
O
R
E-503
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
GENERAL NOTES:
SCALE: NTS
SECONDARY OPERATOR CONTROL STATIONA1
SINGLE AXIS MASTER SWITCH
1. FOR CLARITY, NOT ALL COMPONENTS ARE SHOWN.
2. REFER TO ADDITIONAL SPECIFICATIONS IN SECTION
41 22 13.74 26.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS
AND CONDITIONS.
4. DRAWING IS CONCEPTUAL. OMISSION OF
COMPONENTS FROM THIS DRAWING SHALL NOT BE
CONSTRUED AS PERMITTING DEVIATIONS FROM
CODE OR FROM THE SPECIFICATIONS.
5. CONTRACTOR SHALL DESIGN AND SUBMIT FOR
APPROVAL IN ACCORDANCE WITH SPECIFICATION
SECTIONS 26 05 00.01 26 AND 41 22 13.74 26.
LEGEND:
AUX HOIST
BRAKE FAILURE
LAMP
RADIO ON LAMP
CRANE ON LAMPSTART STOP
MAIN HOIST
BRAKE FAILURE
LAMP
HOIST OVERLOAD
WARNING LAMP
HIGH LOAD
WARNING LAMP
FLOODLIGHTS
ON/OFF
HOIST SPEED
SELECTOR
INDICATION LIGHT
MOMENTARY PUSH BUTTON
E-STOP BUTTON
(MAINTAINED, PUSH-PULL, TWIST TO RELEASE)
MAINTAINED SELECTOR SWITCH
GANTRY
MASTER
SWITCH
TROLLEY
MASTER
SWITCH
MAIN HOIST
MASTER SWITCH
AUX HOIST
MASTER SWITCH
ALARM
SILENCE
IR HEATER
ON/OFF
TROLLEY
SELECTOR
EMERGENCY
STOP HORN OPERATING
SOURCE
SELECTOR
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
G P1
_E
-6
XX
X.
dw g
D . T
R O
W
BR
ID
G
E, P
.E
P.
H
AR
PO
LE
E.
J
AC
KS
O N
, P .E
JO
R
D
AN
F
IN
K, P
.E
IN
ST
AL
L
O N
E
LI
N E
D
IA
G R
AM
E-601
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
GANTRY
BRAKES
VFD
GANTRY
MAIN LINE
CONTACTOR
PANELBOARD
MAIN
UTILITY
DISCONNECT
480V MCC-15
208(240)/120VAC PANELBOARD
480VAC PANELBOARD
CONTROL PANEL
CAB
LIGHTS
MACHINERY
HOUSE
LIGHTS
CATWALK
LIGHTS
480VAC POWER
OUTLET
480VAC POWER
OUTLET
AIR CONDITIONER CAB
HEATERS
MAINTENANCE
HOIST
480V-120/240V
UTILITY
XFMR
MACHINE HOUSE
EXHAUST FAN
FLOODLIGHTS CAB
RECEPTACLES
MACHINE HOUSE
RECEPTACLES
GANTRY
RECEPTACLES
BRAKE
HEATERS
LIGHTS AND
INDICATIONS
MOTOR
HEATERS
MAIN LINE
DISCONNECT
LOAD REACTOR, TYP
LINE REACTOR, TYP
RUNWAY CONDUCTOR AND
COLLECTOR SYSTEM
480V/60HZ
(REPLACE)
RUNWAY CONDUCTOR FEEDERS
CONDUCTORS LOCATED IN EXISTING CONDUIT
SEE REFERENCE DRAWINGS FOR CONDUIT ROUTING
7.5
HP
7.5
HP
BB
INTAKE DECK
BREAKER ENCLOSURE
SPARE
SPARES (3)
4C
1. 187-c20-72/87.2 CONDUIT AND GROUNDING POWERHOUSE
UPSTREAM WALL
BRAKE
CONTROLLER
3-1/C #4/0 + #4 GND
200A
225A
IR HEATERS
GENERAL NOTES:
RESOURCE DRAWINGS:
SCALE: NTS
ONE LINE DIAGRAMA1
TROLLEY
BRAKES
VFD
AUX HOIST TROLLEY
LOAD REACTOR, TYP
LINE REACTOR, TYP
X
HP
X
HP
BB
BRAKE
CONTROLLER
AUX HOIST
BRAKES
VFD
AUX HOIST
LOAD REACTOR, TYP
LINE REACTOR, TYP
BB
BRAKE
CONTROLLER
MAIN HOIST
BRAKES
VFD
MAIN HOIST
LOAD REACTOR, TYP
LINE REACTOR, TYP
HP
JIB HOIST HOLDING
BRAKES
VFD
JIB HOIST HOLDING
LOAD REACTOR, TYP
LINE REACTOR, TYP
B
BRAKE
CONTROLLER
HP
JIB HOIST OPERATOR
BRAKES
VFD
JIB HOIST OPERATOR
LOAD REACTOR, TYP
LINE REACTOR, TYP
B
BRAKE
CONTROLLER
HP
JIB HOIST SLEW
BRAKES
VFD
JIB HOIST SLEW
LOAD REACTOR, TYP
LINE REACTOR, TYP
B
BRAKE
CONTROLLER
HP
CONTROL
CIRCUITS
BB
HP
BRAKE
CONTROLLER
3-1/C #4/0 + #6 GND
1. RED/BOLD INDICATES NEW EQUIPMENT TO BE INSTALLED.
2. FOR CLARITY, NOT ALL COMPONENTS ARE SHOWN.
3. REPLACE FEEDER CONDUCTORS FROM INTAKE DECK BREAKERS
TO NEW CRANE RUNWAY CONDUCTOR SYSTEM.
4. DRAWING IS CONCEPTUAL, OMISSION OF PROTECTIVE DEVICES,
WIRING, AND OTHER COMPONENTS FROM THIS DRAWING SHALL
NOT BE CONSTRUED AS PERMITTING DEVIATION FROM CODE OR
FROM THE SPECIFICATIONS.
5. THE BREAKER/CIRCUIT QUANTITY IS CONCEPTUAL, MORE
BREAKERS AND CIRCUITS ARE REQUIRED TO MEET THE
SPECIFICATION.
6. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND
CONDITIONS.
7. CONTRACTOR SHALL DESIGN AND SUBMIT FOR APPROVAL
COMPLETE POWER, LIGHTING, AND CONTROL SYSTEMS IN
ACCORDANCE WITH SPECIFICATIONS.
8. MOTOR SIZES SHOWN ARE FOR REFERENCE ONLY. SIZE MOTORS
PER SPECIFICATION SECTION 41 22 13.18 26.
9. TROLLEY DRIVE MOTOR(S) TO BE SIZED BY CONTRACTOR. PLEASE
REFER TO SPECIFICATION SECTION 41 22 13.72 26, PARAGRAPH
"TROLLEY DRIVE".
10. CONTRACTOR TO VERIFY THAT EXISTING INTAKE DECK BREAKER
ENCLOSURE MAY BE REUSED FOR THE NEW 200A CIRCUIT BREAKER.
IF EXISTING ENCLOSURE IS FOUND TO NOT BE COMPATIBLE WITH NEW
CIRCUIT BREAKER, CONTRACTOR WILL MODIFY THE ENCLOSURE AS
NECESSARY.
GANTRY
STORM
BRAKES
BB
BRAKE
CONTROLLER
TROLLEY
BRAKES
VFD
MAIN HOIST TROLLEY
LOAD REACTOR, TYP
X
HP
X
HP
BB
BRAKE
CONTROLLER
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
H
YD
R O
EL
EC
TR
IC
D
ES
IG
N
C
EN
TE
R
PO
R
TL
AN
D , O
R
EG
O N
O M
AH
A
D
IS
TR
IC
T O
M
AH
A N
EB
R
AS
KA
C
AP
IT
O
L
AV
E.
, O
M
AH
A N
E
M
AY
D R
AW
IN
G N
O
FI
LE
N
AM
E:
AN
SI
D
W
F2
5R A0
G
AV
IN
S
PO
IN
T D
AM
M
IS
SO
U R
I R
IV
ER
PO
W
ER
H O
U
SE
IN
TA
KE
C
R
AN
E R
EP
LA
C
EM
| Sheets and Views |
| GP104_G-001XXX-G-001 ANSI 'D' |
| GP104_G-002XXX-Sheet 1 |
| GP104_G-003XXX-Sheet 1 |
| GP104_G-201XXX-Sheet 1 |
| GP104_G-202XXX-Sheet 1 |
| GP104_G-401XXX-Sheet 1 |
| GP104_G-402XXX-Sheet 1 |
| GP104_G-403XXX-Sheet 1 |
| GP104_G-901XXX-Sheet 1 |
| GP104_G-902XXX-Sheet 1 |
| GP104_S-901XXX-Sheet 1 |
| GP104_M-401XXX-Sheet 1 |
| GP104_M-402XXX-Sheet 1 |
| GP104_E-201XXX-Sheet 1 |
| GP104_E-501XXX-Sheet 1 |
| GP104_E-502XXX-Sheet 1 |
| GP104_E-503XXX-Sheet 1 |
| GP104_E-601XXX-Sheet 1 |
| 2025-05-12T16:24:45-0700 | |
| CALNON.JAMES.D.1231641170 |
| 2025-05-13T06:49:20-0700 | |
| YEN.JOHN.ZHONG.1386572999 |
| 2025-05-13T09:48:07-0700 | |
| FINK.JORDAN.S.1391890664 |
File details come from the government source that posted it. Updated .