This document appears to be a set of electrical and mechanical plans for the South Entry Gate project at Minot Air Force Base in North Dakota. The plans provide detailed design information for electrical and communications infrastructure, as well as mechanical systems and equipment for the guard booths and inspection bays.
The key details include the layout of underground conduits, handholes, and other electrical and communications components. The mechanical plans show the placement of HVAC equipment, gas piping, exhaust systems, and other mechanical systems for the buildings. The plans also include specific requirements and notes, such as equipment locations, conduit sizing, utility coordination, and installation standards. This appears to be part of the solicitation package for the overall South Entry Gate construction project at Minot AFB.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CP CP CP
TP
COMM
COMM
COMM
COMM
COMM
COMM
COMMCOMMCOMMCOMM
COMM
COMM
COMM
EEEEEEEE
18" CMP
INVERT = 1639.033
18" CMP
INVERT = 1638.961
8FT CHAIN LINK WITH BARB WIRE
8FT C
H
AIN
LIN
K W
ITH
BAR
B W
IR
E
H
H
COMM
COMM
COMM
E
E
E
E
E
E
E
E
E
E
E E E E E
E E
E E
E E
E E
1"C PVC, LOOP
DETECTOR WIRE
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
L2
1. 4' X 4' COMM HANDHOLE
2. NEW SECTIONALIZING CABINET BY UTILITY. VERENDRYE ELECTRIC
COOPERATIVE WILL PROVIDE ALL PRIMARY SIDE ELECTRICAL
WORK.
3. TRANSFORMER LOCATION. TRANSFORMER PROVIDED BY
VERENDRYE ELECTRIC COOPERATIVE. SEE SHEET EP600 FOR SIZE.
4. 3' X 6' COMM HANDHOLE
5. 3' X 6' POWER HANDHOLE
6. 2' X 3' COMM HANDHOLE
7. REPLACE EXISTING POLE AND REMOVE FOUNDATION. TURN OVER
EXISTING POLE AND LUMINAIRE TO THE LOCAL UTILITY,
VERENDRYE ELECTRIC COOPERATIVE.
8. 2' X 2' COMM HANDHOLE
9. 2' X 2' POWER HANDHOLE
10. LOCATION FOR AVB EPU AND PANEL BG1.
11. LOCATION FOR OVERWATCH ENCLOSURE AND CONTROL PANEL.
12. 2' X 3' POWER HANDHOLE
13. PULL 12-STRAND FIBER BACK TO THIS LOCATION AND PROTECT IN
PLACE UNTIL NEW PATHWAY IS ESTABLISHED. THEN REPULL TO
NEW COMMUNICATIONS ROOM.
14. CONNECT TO EXISTING COPPER AND PULL 50 STRAND COPPER TO
NEW COMMUNICATIONS ROOM.
15. LOCATION FOR POV SEARCH CONTROL PANEL FOR AVB SYSTEM.
TP
TP
TP
E
H
MW
G
S
ELEC
L
TP
C
C
J
J
J
J
C
C
C
TP
TP
S
TP
J
J
J
TP
TPELEC
S
J
C TP
TP
S
E
C
J
J
TP
TPTP
E
C
C
PIV
TP
TP
TP
D
S
SVE
V
S
S
S S
TP
TP
TP
UNDERGROUND PRIMARY/MEDIUM VOLTAGE
COMMUNICATIONS HANDHOLE
UNDERGROUND COMMUNICATIONS CONDUIT
UNDERGROUND SECONDARY VOLTAGE
COMM
E
H
ES
ELECTRICAL HANDHOLEE
ABOVE GROUND ELECTRICAL VAULTE
ROADWAY LIGHT
CCTV POLE
1. CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND
EXISTENCE OF ALL UTILITIES SHOWN PRIOR TO
CONSTRUCTION. ANY UTILITY DAMAGED SHALL BE REPAIRED
AT NO ADDITIONAL COST TO THE GOVERNMENT. PROVIDE
REPAIRS THAT MEET OR EXCEED THE QUALITY OF
CONSTRUCTION PRIOR TO DAMAGE.
2. MAINTAIN EXISTING UTILITY SERVICES AT ALL TIMES EXCEPT
WHEN SCHEDULED WITH THE CONTRACTING OFFICER.
3. USE #6 AWG FOR ROADWAY LIGHT CIRCUITS UNLESS OTHERWISE
NOTED.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
M
IE
3E S1
.d w g
S.
L
IN
D
G R
EN
J.
M
O
EN
C H
J.
M
O
EN
C H
S.
L
IN
D
G R
EN
EL
EC
TR
IC
AL
S
IT
E
PL
AN
C :\T
EM
P\
N W
O
1\ G
6E D
XJ
M
7\ D
6\
M
IE
3E S1
.D
W G
9:
:2
PM
/2 2/
AE
C
_N C
S_ 4_
M O
N O
.C
TB
G 6E
D
XJ
M
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
E
O M
AH
A, N E
/1
1/
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
AN
SI
D
W
F2
4R
M
IN
O T
AF
B, N O
R
TH
D
AK
O
TA
AD
AL
S O
U
TH
G
AT
E
EC
F
D
ES
IG
N
ES101
AR
EA
P
LA
N
A1 SCALE: 1" = 40' - 0"
ELECTRICAL AND COMMUNICATIONS SITE PLAN
40' 80'0
NORTH
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T
ES
NORTH
SCALE: 1" = 800'
GENERAL NOTES
KEYNOTES
LEGEND
KEY PLAN
AM
. 0
1:
G
EN
ER
AL
R
EV
IS
IO
N S
-2 2-
C
C
C
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
G
G
G
G
G
G
G
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
8FT CHAIN LINK WITH BARB WIRE
COMM
COMM
H
COMM
COMM
COMM
H
E E
E
E
E
COMM
COMM
COMM
COMM
COMM
COMM
H
COMM
C E
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
C
E
ES
ES
ES
ES
E
H
H
H
H
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
E
E E
E E E E E
E E
E E
E E
E E
E E
E E
E
H
E
E
E
E
E
E
E
E
E E E
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-17, 19
P1
GL1-14, 16
P1
GL1-14, 16
P1
GL1-14, 16
P1
GL1-14, 16
P1
GL1-14, 16
P1
GL1-14, 16
P1
GL1-14, 16
P1
GL1-14, 16
P1
GL1-14, 16
P2
GL1-17, 19
P2
GL1-17, 19
P2
GL1-17, 19
2"C PVC 6 STRAND FIBER
4"C PVC, 12
STRAND FIBER
L3
L4
4" PVC CONDUIT
4" PVC CONDUIT
PRIMARY POWER BY UTILITY
1"C PVC, LOOP
DETECTOR WIRE
1"C PVC, LOOP
DETECTOR WIRE
P1
GL1-17, 19
1"C PVC, LOOP
DETECTOR WIRE
4" PVC CONDUIT
4"C PVC, 50 PAIR COPPER
2"C PVC 6 STRAND FIBER
PRIMARY POWER BY UTILITY
4"C PVC, 12
STRAND FIBER
2"C PVC 6 STRAND FIBER
1. 4' X 4' COMM HANDHOLE
2. NEW SECTIONALIZING CABINET BY UTILITY. VERENDRYE ELECTRIC
COOPERATIVE WILL PROVIDE ALL PRIMARY SIDE ELECTRICAL
WORK.
3. TRANSFORMER LOCATION. TRANSFORMER PROVIDED BY
VERENDRYE ELECTRIC COOPERATIVE. SEE SHEET EP600 FOR SIZE.
4. 3' X 6' COMM HANDHOLE
5. 3' X 6' POWER HANDHOLE
6. 2' X 3' COMM HANDHOLE
7. REPLACE EXISTING POLE AND REMOVE FOUNDATION. TURN OVER
EXISTING POLE AND LUMINAIRE TO THE LOCAL UTILITY,
VERENDRYE ELECTRIC COOPERATIVE.
8. 2' X 2' COMM HANDHOLE
9. 2' X 2' POWER HANDHOLE
10. LOCATION FOR AVB EPU AND PANEL BG1.
11. LOCATION FOR OVERWATCH ENCLOSURE AND CONTROL PANEL.
12. 2' X 3' POWER HANDHOLE
13. PULL 12-STRAND FIBER BACK TO THIS LOCATION AND PROTECT IN
PLACE UNTIL NEW PATHWAY IS ESTABLISHED. THEN REPULL TO
NEW COMMUNICATIONS ROOM.
14. CONNECT TO EXISTING COPPER AND PULL 50 STRAND COPPER TO
NEW COMMUNICATIONS ROOM.
15. LOCATION FOR POV SEARCH CONTROL PANEL FOR AVB SYSTEM.
TP
TP
TP
E
H
MW
G
S
ELEC
L
TP
C
C
J
J
J
J
C
C
C
TP
TP
S
TP
J
J
J
TP
TPELEC
S
J
C TP
TP
S
E
C
J
J
TP
TPTP
E
C
C
PIV
TP
TP
TP
D
S
SVE
V
S
S
S S
TP
TP
TP
UNDERGROUND PRIMARY/MEDIUM VOLTAGE
COMMUNICATIONS HANDHOLE
UNDERGROUND COMMUNICATIONS CONDUIT
UNDERGROUND SECONDARY VOLTAGE
COMM
E
H
ES
ELECTRICAL HANDHOLEE
ABOVE GROUND ELECTRICAL VAULTE
ROADWAY LIGHT
CCTV POLE
1. CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND
EXISTENCE OF ALL UTILITIES SHOWN PRIOR TO
CONSTRUCTION. ANY UTILITY DAMAGED SHALL BE REPAIRED
AT NO ADDITIONAL COST TO THE GOVERNMENT. PROVIDE
REPAIRS THAT MEET OR EXCEED THE QUALITY OF
CONSTRUCTION PRIOR TO DAMAGE.
2. MAINTAIN EXISTING UTILITY SERVICES AT ALL TIMES EXCEPT
WHEN SCHEDULED WITH THE CONTRACTING OFFICER.
3. USE #6 AWG FOR ROADWAY LIGHT CIRCUITS UNLESS OTHERWISE
NOTED.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
M
IE
3E S1
.d w g
S.
L
IN
D
G R
EN
J.
M
O
EN
C H
J.
M
O
EN
C H
S.
L
IN
D
G R
EN
EL
EC
TR
IC
AL
S
IT
E
PL
AN
C :\T
EM
P\
N W
O
1\ G
6E D
XJ
M
7\ D
6\
M
IE
3E S1
.D
W G
9:
:5
PM
/2 2/
AE
C
_N C
S_ 4_
M O
N O
.C
TB
G 6E
D
XJ
M
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
E
O M
AH
A, N E
/1
1/
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
AN
SI
D
W
F2
4R
M
IN
O T
AF
B, N O
R
TH
D
AK
O
TA
AD
AL
S O
U
TH
G
AT
E
EC
F
D
ES
IG
N
ES102
AR
EA
P
LA
N
A1 SCALE: 1" = 40' - 0"
ELECTRICAL AND COMMUNICATIONS SITE PLAN
40' 80'0
NORTH
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T
ES
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T
ES
NORTH
SCALE: 1" = 800'
GENERAL NOTES
KEYNOTES
LEGEND
KEY PLAN
AM
. 0
1:
G
EN
ER
AL
R
EV
IS
IO
N S
-2 2-
H
J
J
C
TP
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
E
EE
E
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
COMM
COMM
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
C
C
COMM
COMM
COMM COMM
COMM
COMM
COMM
COMM
COMM
C
COMM
COMM
ES
ES
ES
C
E
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
E
COMM
ESCOMM COMM
COMM
COMM
P2
GL1-17, 19
P2
GL1-17, 19
P2
GL1-17, 19
P2
GL1-17, 19
P2
GL1-17, 19
P2
GL1-17, 19
P1A, POWERED
BY AVB EPU
P1A, POWERED
BY AVB EPU
P1A, POWERED
BY AVB EPU
2"C PVC 6 STRAND FIBER
4" PVC CONDUIT
4" PVC CONDUIT
4" PVC CONDUIT
L7
A1
ES505
A1
ES505
2"C PVC 6 STRAND FIBER
4" PVC CONDUIT
WITH PULL STRING
4" PVC CONDUIT
WITH PULL STRING
2"C PVC, BARRIER COMM CABLE
2"C PVC
6 STRAND FIBER
1. 4' X 4' COMM HANDHOLE
2. NEW SECTIONALIZING CABINET BY UTILITY. VERENDRYE ELECTRIC
COOPERATIVE WILL PROVIDE ALL PRIMARY SIDE ELECTRICAL
WORK.
3. TRANSFORMER LOCATION. TRANSFORMER PROVIDED BY
VERENDRYE ELECTRIC COOPERATIVE. SEE SHEET EP600 FOR SIZE.
4. 3' X 6' COMM HANDHOLE
5. 3' X 6' POWER HANDHOLE
6. 2' X 3' COMM HANDHOLE
7. REPLACE EXISTING POLE AND REMOVE FOUNDATION. TURN OVER
EXISTING POLE AND LUMINAIRE TO THE LOCAL UTILITY,
VERENDRYE ELECTRIC COOPERATIVE.
8. 2' X 2' COMM HANDHOLE
9. 2' X 2' POWER HANDHOLE
10. LOCATION FOR AVB EPU AND PANEL BG1.
11. LOCATION FOR OVERWATCH ENCLOSURE AND CONTROL PANEL.
12. 2' X 3' POWER HANDHOLE
13. PULL 12-STRAND FIBER BACK TO THIS LOCATION AND PROTECT IN
PLACE UNTIL NEW PATHWAY IS ESTABLISHED. THEN REPULL TO
NEW COMMUNICATIONS ROOM.
14. CONNECT TO EXISTING COPPER AND PULL 50 STRAND COPPER TO
NEW COMMUNICATIONS ROOM.
15. LOCATION FOR POV SEARCH CONTROL PANEL FOR AVB SYSTEM.
TP
TP
TP
E
H
MW
G
S
ELEC
L
TP
C
C
J
J
J
J
C
C
C
TP
TP
S
TP
J
J
J
TP
TPELEC
S
J
C TP
TP
S
E
C
J
J
TP
TPTP
E
C
C
PIV
TP
TP
TP
D
S
SVE
V
S
S
S S
TP
TP
TP
UNDERGROUND PRIMARY/MEDIUM VOLTAGE
COMMUNICATIONS HANDHOLE
UNDERGROUND COMMUNICATIONS CONDUIT
UNDERGROUND SECONDARY VOLTAGE
COMM
E
H
ES
ELECTRICAL HANDHOLEE
ABOVE GROUND ELECTRICAL VAULTE
ROADWAY LIGHT
CCTV POLE
1. CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND
EXISTENCE OF ALL UTILITIES SHOWN PRIOR TO
CONSTRUCTION. ANY UTILITY DAMAGED SHALL BE REPAIRED
AT NO ADDITIONAL COST TO THE GOVERNMENT. PROVIDE
REPAIRS THAT MEET OR EXCEED THE QUALITY OF
CONSTRUCTION PRIOR TO DAMAGE.
2. MAINTAIN EXISTING UTILITY SERVICES AT ALL TIMES EXCEPT
WHEN SCHEDULED WITH THE CONTRACTING OFFICER.
3. USE #6 AWG FOR ROADWAY LIGHT CIRCUITS UNLESS OTHERWISE
NOTED.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
M
IE
3E S1
.d w g
S.
L
IN
D
G R
EN
J.
M
O
EN
C H
J.
M
O
EN
C H
S.
L
IN
D
G R
EN
EL
EC
TR
IC
AL
S
IT
E
PL
AN
C :\T
EM
P\
N W
O
1\ G
6E D
XJ
M
7\ D
6\
M
IE
3E S1
.D
W G
9:
:4
PM
/2 2/
AE
C
_N C
S_ 4_
M O
N O
.C
TB
G 6E
D
XJ
M
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
E
O M
AH
A, N E
/1
1/
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
AN
SI
D
W
F2
4R
M
IN
O T
AF
B, N O
R
TH
D
AK
O
TA
AD
AL
S O
U
TH
G
AT
E
EC
F
D
ES
IG
N
ES103
AR
EA
P
LA
N
A1 SCALE: 1" = 40' - 0"
ELECTRICAL AND COMMUNICATIONS SITE PLAN
40' 80'0
NORTH
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T
ES
NORTH
SCALE: 1" = 800'
GENERAL NOTES
KEYNOTES
LEGEND
KEY PLAN
AM
. 0
1:
G
EN
ER
AL
R
EV
IS
IO
N S
-2 2-
F-1
8"ø
EF-5
EF-4
UH-1
RH-1A
RH-3A
CU-1
UH-2
SS-1
CU-2
RH-2A
GAS
METER
1 1/2" NG SEE CIVIL FOR CONTINUATION
EF-2 EF-1
EF-3
A 230
R 100
B 125
R 155
C 100
F 90
TF-1
1 1/2" NG
1" NG
3/4" NG
3/4" NG
3/4" NG
N G
N G
N G
3/4" NG
EF-6
T
S
S
36" x 48" OA LOUVER
WITH MOTORIZED
DAMPER AND
ACTUATOR.
INTERLOCK WITH
EF-5.
48" x 36" OA LOUVER
WITH MOTORIZED
DAMPER AND
ACTUATOR.
INTERLOCK WITH
EF-4.
S
TCO
M-501
12"X12" OA LOUVER WITH
MOTORIZED DAMPER.
INTERLOCK WITH F-1.
BALANCING DAMPER (TYP)
18' A.F.F.
T
A F
B DC E
M-501
T
M-502
M-502
M-501
M-5012
M-501
M-502
M-502
M-502
M-502
GATEHOUSE
102 JANITOR
RESTROOM
COMM.
DRIVER WAITING
INSPECTION
BAYS
MECH/ELEC
K-9 ROOM
EQUIP. STORAGE
M-502
9 10 12
9 10 13
9 10 14
CO
15 16
D 25
E 90
12"X12" EA LOUVER WITH
MOTORIZED DAMPER.
INTERLOCK WITH EF-6.
RH-1B
RH-2B
RH-3B 1
12"X12" OA LOUVER WITH
MOTORIZED DAMPER.
INTERLOCK WITH EF-6.
6" VENT THRU ROOF
8"ø
/4
N
G
N G
1" NG
3/4" NG
3/4" NG
6" VENT THRU ROOF
M-501
6" VENT THRU ROOF
3/4" NG
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
F
IL
E N
A M
E
A D
V E
R T
IS
E
M E
N T
C
U s e rs
\g e d x tw
\D o c u m e n ts
\R e v it F ile s \M
IE
D
M M
P g e d x tw
.r v t
/2
/2
:5
:0
A
M
M-101
C O
M P
O S
IT
E
M E
C H
A N
IC
A
L P
L A
N
M
IN
O T
A F
B N
O R
T H
D A
K O
T A
O M
A H
A D
IS
T
R
IC
T C
A P
IT
O
L A
V E
O M
A H
A N
E
T W
E E
D E
R
T W
E E
D E
R
J S
W E
R C
Z E
K P
.E
J S
W E
R C
Z E
K
/1
/2
W F
R
A D
A L S
O U
T H
G A
T E
E C
F
M
IE
D
M M
P .r v t
FIRST FLOOR MECHANICAL PLAN
KEY NOTES:
1. PROVIDE AND INSTALL GAS-FIRED RADIANT
HEATERS, IN ACCORDANCE WITH (IAW)
MANUFACTURER'S RECOMMENDATIONS. SUPPORT
FROM ROOF STRUCTURE. MOUNT AT 18' A.F.F. TOP
REFLECTORS SHALL BE PROVIDED ALONG THE
HORIZONTAL LENGTH OF THE RADIANT PIPE AND
TAILPIPE. EXTEND OUTSIDE AIR SUPPLY AND
EXHAUST PIPING THROUGH BUILDING ROOF AS
INDICATED IAW SYSTEM MANUFACTURER'S
RECOMMENDATIONS. TERMINATE WITH PEST
SCREEN AND WEATHER HOOD. SEAL ALL
PENETRATIONS WATER TIGHT. COORDINATE
MOUNTING LOCATION TO MAINTAIN ALL BURNER
CLEARANCES AND COORDINATE WITH LIGHTING.
2. MAINTAIN SAFE DISTANCE FROM OVERHEAD
RADIANT HEATING SYSTEM FOR PEOPLE STANDING
ON THE INSPECTION PLATFORMS. REFER TO ARCH.
SHEETS FOR THE BUILDING CROSS SECTION VIEWS.
POSITION OUTSIDE AIR (OA) PIPE 18' A.F.F. TYP.
3. PROVIDE SIDE REFLECTORS ALONG THE LENGTH OF
THE OVERHEAD RADIANT HEATING SYSTEM, ALONG
SIDES ADJACENT BUILDING WALLS.
4. EXHAUST FLUE AND COMBUSTION AIR INTAKE
THROUGH WALL PER FURNACE MANUFACTURER'S
INSTALLATION REQUIREMENTS. MIN 8' ABOVE
GRADE. SIZE AS PER MANUFACTURER'S
RECOMMENDATIONS. PROVIDE WITH PEST SCREEN.
SEAL WALL PENETRATION WATER TIGHT.
5. MECHANICAL EXHAUST SYSTEM ZONE
TEMPERATURE SENSOR. PROVIDE INPUT FROM
TEMPERATURE SENSOR TO HVAC CONTROL SYSTEM
FOR OPERATION OF EF-6 AND CORRESPONDING
OUTSIDE AIR DAMPER AND FOR OPERATION OF UH-1.
6. OUTDOOR CONDENSING UNITS ON 6" THICK
CONCRETE PADS. CONCRETE PADS SHALL EXTEND
6" PAST ALL SIDES OF THE CONDENSING UNITS.
7. PROVIDE SPLIT SYSTEM INDOOR UNIT WITH
CONDENSATE OVERFLOW CUT-OFF SWITCH.
PROVIDE UNIT WITH 3/4" CONDENSATE DRAIN LINE
FROM SS-1. ROUTE DRAIN LINE OUTSIDE.
8. FURNACE SYSTEM ZONE TEMPERATURE SENSOR.
TEMPERATURE SENSOR SHALL BE LOCATED
APPROXIMATELY 5' A.F.F. PROVIDE 2 ADDITIONAL
FEET OF COILED CONTROL WIRE IN WALL TO ALLOW
FOR FUTURE HEIGHT ADJUSTMENT IF REQUIRED.
9. SENSOR SHALL BE LOCATED APPROXIMATELY 5'
A.F.F. MOUNT TO 1" THICK INSULATING PAD
PERMANENTLY ATTACHED TO WALL.
10. PROVIDE INPUT FROM TEMPERATURE SENSOR TO
HVAC CONTROL SYSTEM FOR OPERATION OF EF-4,
EF-5 AND ASSOCIATED OUTSIDE AIR DAMPERS.
PROVIDE SUN SHIELD ON EACH SIDE OF
TEMPERATURE SENSOR.
11. PROVIDE INPUT FROM CARBON MONOXIDE (CO)
SENSOR TO HVAC CONTROL SYSTEM FOR
OPERATION OF EF-4, EF-5 AND CORRESPONDING
OUTSIDE AIR DAMPERS.
12. GAS-FIRED RADIANT SYSTEM ZONE TEMPERATURE
SENSOR. PROVIDE INPUT FROM TEMPERATURE
SENSOR TO HVAC CONTROL SYSTEM FOR
OPERATION OF RH-1A & RH-1B.
13. GAS-FIRED RADIANT SYSTEM ZONE TEMPERATURE
SENSOR. PROVIDE INPUT FROM TEMPERATURE
SENSOR TO HVAC CONTROL SYSTEM FOR
OPERATION OF RH-2A & RH-2B.
14. GAS-FIRED RADIANT SYSTEM ZONE TEMPERATURE
SENSOR. PROVIDE INPUT FROM TEMPERATURE
SENSOR TO HVAC CONTROL SYSTEM FOR
OPERATION OF RH-3A & RH-3B.
15. OUTSIDE AIR TEMPERATURE SENSOR. PROVIDE
INPUT FROM TEMPERATURE SENSOR TO HVAC
CONTROL SYSTEM.
16. SENSOR SHALL BE LOCATED APPROXIMATELY 12'
A.F.F. MOUNT TO 1" THICK INSULATING PAD
PERMANENTLY ATTACHED TO WALL. PROTECT
SENSOR ON EVERY SIDE WITH SUN-SHIELD.
17. EXTEND EXHAUST DUCT THROUGH BUILDING SIDE
WALL. TERMINATE WITH WALL CAP WITH PEST
SCREEN. SEAL WALL PENETRATION WATER TIGHT.
TYP OF 3.
18. COMM. ROOM TEMPERATURE SENSOR. PROVIDE
INPUT FROM TEMPERATURE SENSOR TO HVAC
CONTROL SYSTEM.
19. PROVIDE EXHAUST INLET WITH REMOVABLE BIRD
SCREEN.
20. NATURAL GAS CONNECTION TO WATER HEATER.
PROVIDE ISOLATION VALVE, UNION, AND 6" DRIP LEG.
GENERAL NOTES:
1. EQUIPMENT AND HVAC COMPONENTS SHALL BE
INSTALLED WITH ADEQUATE CLEARANCE TO PERMIT
ACCESS FOR OPERATION AND MAINTENANCE.
CLEARANCE SHALL COMPLY WITH MANUFACTURERS
REQUIREMENTS, WHERE APPLICABLE.
2. COORDINATE DUCT ELEVATIONS WITH STRUCTURAL
AND ELECTRICAL SYSTEMS.
3. FLEXIBLE DUCT CONNECTED TO DIFFUSERS SHALL BE
LIMITED TO A MAXIMUM LENGTH OF 3 FEET, WHERE
APPLICABLE. FLEXIBLE DUCT MUST NOT BE
INSTALLED ABOVE HARD CEILINGS.
4. ALL DUCTWORK SHALL BE SEAL CLASS A.
5. PROVIDE MANUAL BALANCING DAMPERS REQUIRED
TO BALANCE AIRFLOWS TO VALUES SHOWN ON THIS
SHEET. LOCATE DAMPERS AS FAR FROM DIFFUSER
AS POSSIBLE, AS SHOWN.
A
M
G
E N
E R
A L R
E V
IS
IO
N S
-2
-2
J
M,2
D
BMS
BMS
D B
CB1
G,WP
G,WP
G,WP
GU1-5
CG1-1
CG1-3
CG1-7,9
4 5
CB1
F41
CG1-2
4D
BELOW
COUNTER
10 2
2"C TO
SIGNAL
HH ON
ISLAND
1"C FOR UPS
CIRCUIT
2"C TO FROM
SIGNAL HH
TWO 2"C TO SIGNAL
HH FOR IDS
2"C TO
SIGNAL HH
FOR CCTV
TWO SPARE 1/2"C
TO GUARDBOOTH
PANELBOARD.
SPARE 1"C TO
SIGNAL HH.
D14 E-101
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
AD
VE
R
TI
SE
M
EN
T
C :\U se rs
\g 6e dx jm
7\ D oc um en ts
\M
IE
3_ D
M _E
_g 6e dx jm
7.
rv t 4/
/2
9:
:0
PM
E-101
G U
AR
D
B O
O
TH
P
LA
N S
M
IN
O T
AF
B, N O
R
TH
D
AK
O
TA
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
E.
O M
AH
A, N E
J.
M
O
EN
C H
J.
M
O
EN
C H
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/1
1/
W
F2
4R
AD
AL
S
O U
TH
G
AT
E
EC
F
M
IE
3_ D
M _E
.rv t
1/2" = 1'-0"K8 GUARD BOOTH POWER PLAN
1/2" = 1'-0"K14
GUARD BOOTH LIGHTING REFLECTED
CEILING PLAN
1/2" = 1'-0"F2
GUARD BOOTH TELECOMMUNICATION
PLAN
PLAN NORTH
0 1' 2' 4'
1/2" = 1'-0"K2 GUARD BOOTH GROUNDING PLAN
1/2" = 1'-0"D14 GUARD BOOTH SIGNAL ELEVATION
1/2" = 1'-0"F8 GUARD BOOTH SIGNAL
ELECTRICAL KEYNOTES
1 GROUNDING CONDUCTORS. SEE GROUNDING DIAGRAM SHEET EG600.
2 GUARD BOOTH 2 QUAD CIRCUIT IS ON GUPS-9. 1"C. 1"C TO POWER HAND HOLE.
3 PANELBOARD SUPPLIED BY GUARD BOOTH MANUFACTURER. SEE PANEL SCHEDULE ON GUARD BOOTH SHEET EP603. PROVIDE EXTERNAL SURGE
PROTECTIVE DEVICE. MOUNT BELOW WINDOW.
4 MOTOR DISCONNECT SWITCH. SWITCH WITH BUILT IN THERMAL OVERLOADS. SUPPLIED BY BOOTH MANUFACTURERS.
5 MECHANICAL UNIT SHALL HAVE A 26 SEER OR BETTER. LOW AMBIENT HEATING (OVER 90% CAPACITY @ 5 DEGREES F).
6 WEATHERPROOF, GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE MOUNTED 6" BELOW EAVE.
7 LIGHT SWITCH FOR INTERIOR LIGHT. SWITCH AND LUMINAIRE(S) PROVIDED AS PART OF GUARD BOOTH. LUMINAIRE MOUNTING SHALL BE RECESSED IN
CEILING.
8 THREE POSITION SWITCH FOR OPEN / CLOSED SIGN. TWO POSITIONS ARE ALLOCATED TO SWITCHING BETWEEN OPEN AND CLOSED. ANOTHER POSITION
TURNS THE SIGN OFF. SWITCH WILL HAVE ANNOTATED OR VISUAL INDICATOR TO CONVEY WHETHER SIGN IS DISPLAYING MESSAGE FOR OPEN, DISPLAYING
MESSAGE FOR CLOSED, OR OFF.
9 PROVIDE THREE 1-1 1/2" C HOLES WITH GROMETTS ALONG BACK OF COUNTER. COORDINATE GROMETT LOCATIONS WITH ELECTRONIC PANELS AND
SCREEN ON COUNTER TOP.
10 VOICE/DATA JACK TO BE MOUNTED BELOW COUNTER. SEE RISER DIAGRAM ON TN601GH. RUN THE CAT 6 CABLES TO THREE STAGE PROTECTIVE ENTRANCE TERMINAL (PET) PRIOR TO RUNNING CAT 6 CABLES TO JACKS. RUN CAT 6 CABLES IN 1"C FROM PET TO JACKS.
11 MOUNT A 4-INCH SQUARE JUNCTION BOX BELOW QUAD RECEPTACLE. SPLICE 2 #4 & #4 GRD TO 2 #12 & 12 GRD IN JUNCTION BOX. CONNECT #12 TO
RECEPTACLE.
12 AUTOMATED INSTALLATION ENTRY (AIE) CABINET WITH BACK PLANE. SIZE IS 8"x8"x4"D. MOUNT BELOW COUNTER.
13 DURESS BUTTON. PROVIDE 1"C TO GATEHOUSE SECURITY CABINET WITH PULL WIRE FOR FUTURE DURESS BUTTON. MOUNT JUNCTION BOX ON COUNTER
FOR FUTURE CONNECTION OF DURESS BUTTON. PROVIDE RIGID STEEL CONDUIT AND JUNCTION BOXES WITH TAMPER RESISTANT SCREWS.
14 GUARD BOOTH BARRIER CONTROL PANEL, SEE DETAIL 2 ON SHEET TY101.
15 AIE COMPUTER, MONITOR, AND PHONE (N.I.C.).
16 PROVIDE JUNCTION BOX AND 3/4" C TO JUNCTION BOX USED FOR BALANCED MAGNETIC SWITCH (BMS) N.I.C. PROVIDE RIGID STEEL CONDUIT AND JUNCTION
BOXES WITH TAMPER RESISTANT SCREWS. MOUNT JUNCTION BOX ABOVE DOOR.
A
M . 0
1:
G
EN
ER
A L
R
EV
I S
IO
N S
4-
-2
| MIE3ES101 |
| Sheets and Views |
| ES101 |
| Sheet 1 |
| MIE3ES102 |
| Sheets and Views |
| ES102 |
| Sheet 1 |
| MIE3ES103 |
| Sheets and Views |
| ES103 |
| Sheet 1 |
| MIE3M-101 |
| Sheets |
| M-101 - COMPOSITE MECHANICAL PLAN |
| MIE3E-101 |
| Sheets |
| E-101 - GUARD BOOTH PLANS |
File details come from the government source that posted it. Updated .