Am0005_FR00105MD101.pdf

PDF 736 KB Posted

Attached to
FORT RANDALL PRIVATE OFFICE RENOVATION Federal contract opportunity
Solicitation number
W9128F23Q0001
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

View the file

Other files for this federal contract opportunity

Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

S I Z

E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

10" 0

10" 0 10" 0

10" 0

10" 0

6" 0

14" 0

8" 0

8" 0

12" 0

12" 0

8" 0

8" 0

8" 0

10" 0

10" 0

SD-3SD-3

SD-3 SD-3

SD-3

SD-3

SD-2

SD-2

SD-1

SD-1

SD-1

SD-5

SD-1

SD-4

RG-2

SD-2

SD-2

DH-1

X

6" 0

6" 0 6" 0

SD-5

14" 0

SD-5

14" 0

SD-5

X

RG-1

DH-214 X 7

SD-2

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

16 X 7

T

RR-1

T

RR-1

PARTIAL PLAN - ELEV. 1291.0

12" 0 5'

SCALE: INCH = 1 FOOT

E

E

12" 0 5'

SCALE: INCH = 1 FOOT

RG-1

10" 0

RG-1

10" 0

T

12" X 12"

DH-3

14" 0

MECHANICAL DEMOLITION GENERAL NOTES

AND HEADS TO AVOID DAMAGE OR ACTIVATION.

AREAS. THE CONTRACTOR SHALL PROTECT THE SPRINKLER SYSTEM

THE SPRINKLER SYSTEM WILL REMAIN OPERATIONAL IN THE WORK

THE FIRE SPRINKLERS ARE NOT ABLE TO BE SHUT OFF PER ROOM, SO

REPLACED WITH NEW PER ARCHITECTURAL NEW WORK PLAN.

SALVAGED FOR LATER REINSTALLATION UNLESS OTHERWISE TO BE

AND ACCESSORIES REMOVED DURING THE WORK SHALL BE

CEILING TILES, CEILING GRID, WALL MOLDINGS, CEILING HANGERS

CONDITIONS.

CHANGED FROM THAT SHOWN ON THIS SHEET. FIELD VERIFY EXACT

LOCATION OF EXISTING WALLS AND ROOM DESCRIPTIONS HAVE

DEMOLITION WORK.

ETC. ARE APPROXIMATE. FIELD VERIFY PRIOR TO BEGINNING

LOCATION OF EXISTING DUCTWORK, DIFFUSERS, RETURN GRILLES,

TO BE REMOVED AND DISPOSED SHOWN IN GREEN.

EXISTING ITEMS TO REMAIN SHOWN IN HALF TONE (GRAY) AND ITEMS 1.

2.

3.

795 CFM

4.

BREAKROOM

MECHANICAL KEY NOTES

LAY-IN CEILING TYPE SUPPLY AIR DIFFUSER SD-5.

REMOVE AND DISPOSE OF EXISTING 14" FLEXIBLE DUCT AND 24" X 24" 1.

5.

A N

S I

D

P O

W E

R H

O U

S E

P R

IV

A

T E

O F

F

IC

E R

E N

O V

A T

IO

N

F O

R T

R A

N D

A L

L D

A M

S

O U

T H

D A

K O

T A

W F

Q

/1

/2

O M

A H

A

N E

C A

P

IT

O L

A V

E

O M

A H

A D

IS

T

R

IC

T

F

IL

E

N U

M B

E R

F

IL

E N

A M

E

J

S W

E R

C Z

E K

C H

A N

IC

A

L D

E M

O L

IT

IO

N P

L A

N

MD101

K

P A

R K

J

S W

E R

C Z

F R

M

D

.d g n

P A

R

A

-G

E N

E R

A L

R E

V

IS

IO

N

S

/2

/2