Am0005_FR00105MD101.pdf
PDF 736 KB Posted
- Attached to
- FORT RANDALL PRIVATE OFFICE RENOVATION Federal contract opportunity
- Solicitation number
- W9128F23Q0001
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
10" 0
10" 0 10" 0
10" 0
10" 0
6" 0
14" 0
8" 0
8" 0
12" 0
12" 0
8" 0
8" 0
8" 0
10" 0
10" 0
SD-3SD-3
SD-3 SD-3
SD-3
SD-3
SD-2
SD-2
SD-1
SD-1
SD-1
SD-5
SD-1
SD-4
RG-2
SD-2
SD-2
DH-1
X
6" 0
6" 0 6" 0
SD-5
14" 0
SD-5
14" 0
SD-5
X
RG-1
DH-214 X 7
SD-2
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
16 X 7
T
RR-1
T
RR-1
PARTIAL PLAN - ELEV. 1291.0
12" 0 5'
SCALE: INCH = 1 FOOT
E
E
12" 0 5'
SCALE: INCH = 1 FOOT
RG-1
10" 0
RG-1
10" 0
T
12" X 12"
DH-3
14" 0
MECHANICAL DEMOLITION GENERAL NOTES
AND HEADS TO AVOID DAMAGE OR ACTIVATION.
AREAS. THE CONTRACTOR SHALL PROTECT THE SPRINKLER SYSTEM
THE SPRINKLER SYSTEM WILL REMAIN OPERATIONAL IN THE WORK
THE FIRE SPRINKLERS ARE NOT ABLE TO BE SHUT OFF PER ROOM, SO
REPLACED WITH NEW PER ARCHITECTURAL NEW WORK PLAN.
SALVAGED FOR LATER REINSTALLATION UNLESS OTHERWISE TO BE
AND ACCESSORIES REMOVED DURING THE WORK SHALL BE
CEILING TILES, CEILING GRID, WALL MOLDINGS, CEILING HANGERS
CONDITIONS.
CHANGED FROM THAT SHOWN ON THIS SHEET. FIELD VERIFY EXACT
LOCATION OF EXISTING WALLS AND ROOM DESCRIPTIONS HAVE
DEMOLITION WORK.
ETC. ARE APPROXIMATE. FIELD VERIFY PRIOR TO BEGINNING
LOCATION OF EXISTING DUCTWORK, DIFFUSERS, RETURN GRILLES,
TO BE REMOVED AND DISPOSED SHOWN IN GREEN.
EXISTING ITEMS TO REMAIN SHOWN IN HALF TONE (GRAY) AND ITEMS 1.
2.
3.
795 CFM
4.
BREAKROOM
MECHANICAL KEY NOTES
LAY-IN CEILING TYPE SUPPLY AIR DIFFUSER SD-5.
REMOVE AND DISPOSE OF EXISTING 14" FLEXIBLE DUCT AND 24" X 24" 1.
5.
A N
S I
D
P O
W E
R H
O U
S E
P R
IV
A
T E
O F
F
IC
E R
E N
O V
A T
IO
N
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
Q
/1
/2
O M
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
IC
T
F
IL
E
N U
M B
E R
F
IL
E N
A M
E
J
S W
E R
C Z
E K
C H
A N
IC
A
L D
E M
O L
IT
IO
N P
L A
N
MD101
K
P A
R K
J
S W
E R
C Z
F R
M
D
.d g n
P A
R
A
-G
E N
E R
A L
R E
V
IS
IO
N
S
/2
/2