DRAWINGS - W9128F23Q0001-PH Private Office Renovation.PDF
PDF 8 MB Posted
- Attached to
- FORT RANDALL PRIVATE OFFICE RENOVATION Federal contract opportunity
- Solicitation number
- W9128F23Q0001
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9128F23Q0001 AM0008 - 9 Feb 23.pdf | ||
| 28 31 70 Am-0008.pdf | ||
| W9128F23Q0001 AM0007 - 3 Feb 23.pdf | ||
| 28 31 70 Am-0007.pdf | ||
| W9128F23Q0001 AM0006 - 2 Feb 23.pdf | ||
| Am0005_FR00105MD101.pdf | ||
| Am0005_FR00105FA502.pdf | ||
| 28 31 70 Am-0005.pdf | ||
| W9128F23Q0001 AM0005 - 27 Jan 23_RELEASED.pdf | ||
| Am0005_FR00105M-101.pdf | ||
| W9128F23Q0001 AM0004 - 18 Jan 23.pdf | ||
| W9128F23Q0001 AM0003 - 12 Jan 23.pdf | ||
| FR Private Office Renvoation_23Q0001_ Site Visit_Sign-in Sheet_Redacted.pdf | ||
| Am0002_FR00105FA900.pdf | ||
| 01 12 00 Am-0002.pdf | ||
| 28 31 70 Am-0002.pdf | ||
| W9128F23Q0001 AM0002 - 6 Jan 23.pdf | ||
| Am0002_FR00105FA901.pdf | ||
| AM0001 - W9128F23Q0001 - FR Private Office Renovation.pdf | ||
| SPECS - W9128F23Q0001 - PH Private Office Renovation.pdf | ||
| BRAND NAME - W9128F23Q0001-PH Private Office Renovation.pdf | ||
| W9128F23Q0001_FR Private Office Renovation.pdf |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F R
\F
R G
-0 -n e w d g n
:5
:3
A
M
/1
/2
P D
A
E C p d f.
p lt c fg
D S
A
E C
S c re e n F u ll
S iz e .d s c ri p t
O M
A H
A D
IS
T
R
IC
T
C A
P
IT
O L
A V
E
O M
A H
A
N E
/1
/2
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
A N
S I
D
F
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
P O
W E
R H
O U
S E
P R
IV
A
T E
O F
F
IC
E R
E N
O V
A T
IO
N
R
G
-0
-n e w d g n
M H
O F
F M
A N
M H
O F
F M
A N
M H
O F
F M
A N
M H
O F
F M
A
C
V E
R
I N
D E
X
G-001
OMAHA DISTRICT
FORT RANDALL DAM, SOUTH DAKOTA
POWERHOUSE PRIVATE OFFICE RENOVATION
12/13/2022
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
of Engineers
US Army Corps
ADVERTISEMENT RFQ
g6pmxbas Stamp
F R
\F
R G
-0 d g n
:2
:0
A
M
/1
/2
P D
A
E C p d f.
p lt c fg
D S
A
E C
S c re e n F u ll
S iz e .d s c ri p
A H
A D
IS
T
R
IC
T
C A
P
IT
O L
A V
E
O M
A H
A
N E
/1
/2
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
A N
S I
D
W F
Q
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
P O
W E
R H
O U
S E
P R
IV
A
T E
O F
F
IC
E R
E N
O V
A T
IO
G
-0 d g n
M H
O F
F M
A N
M H
O F
F M
A N
M H
O F
F M
A N
M H
O F
F M
B
B R
E V
IA
T
IO
N
S
G-002
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
COURSE(S)CRS
CROSS GRAINCRG
CORROSIVE RESISTANT STEELCRES
CIRCUMFERENCECRCMF
CARPETCPT
COMPRESSIBLECPRS
COVERCOV
CORRIDORCORR
CONTRACTORCONTR
CONTINUE CONT
CONSTRUCTIONCONSTR
CONNECTCONN
CONCRETECONC
COMPARTMENTCOMPT
COMBUSTIONCOMB
COMMONCOM
COLUMNCOL
CARBON DIOXIDECO2
CLEANOUTCO
COUNTERCNTR
CORNERCNR
CONDUCTIVE NEOPRENE LATEXCNL
CONDUITCND
CONCRETE MASONRY UNITCMU
COMPOSITECMPST
CORRUGATED METAL PIPECMP
CENTIMETER(S)cm
CLEAR WIRED GLASSCLWG
CLEAR(ANCE)CLR
CLOSURECLOS
CLOSETCLO
CONTRACT LIMIT LINECLL
CLEAR GLASSCLGL
CEILING HEIGHTCLG HT
CEILINGCLG
CENTER LINECL
CIRCUIT BREAKERCKT BRKR
CIRCUITCKT
CONSTRUCTION JOINTCJ
CONTROL JOINTCJ
CIRCULARCIRC
CAST-IN-PLACECIP
CURB INLETCI
CAST IRONCI
CHROME PLATEDCHR PL
CHECKCHK
CHIMNEYCHIM
CHAMFERCHFR
CHALKBOARDCH BD
CORNER GUARDCG
CUBIC FEET PER MINUTECFM
COUNTERFLASHINGCFLG
CONDUCTIVE FLOORINGCFI
CERAMICCER
CEMENT PLASTERCEM PLAS
CEMENTCEM
COVER ELEVATIONCE
CLOSED CIRCUIT TELEVISIONCCTV
CUBICLE CURTAIN TRACKCCT
CATCH BASINCB
CAPACITYCAP
CABINETCAB
BOTH WAYSBW
BUILT-UP ROOFINGBUR
BETWEENBTWN
BTU PER HOURBtuH
BRITISH THERMAL UNITBtu
BASEMENTBSMT
BOTH SIDESBS
BRONZEBRZ
BRACKETBRKT
BRICKBRK
BEARING PLATEBRG PL
BEARINGBRG
BRIDGINGBRDG
BRACINGBRCG
BACK PLASTER(ED)BP
BOTTOMBOT
BOTTOM OFBO
BENCHMARKBM
BELOWBLW
BUILDINGBLDG
BUILDING LINEBL
BED JOINTBJT
BITUMINOUSBITUM
BEVELBEV
BRICK EXPANSION JOINTBEJ
BOUNDARYBDRY
BOARDBD
BOOKCASEBC
BULLETIN BOARDBB
ACOUSTICAL WALL TREATMENTAWT
AMERICAN WIRE GAUGEAWG
AVERAGEAVG
AUTOMATICAUTO
ACOUSTICAL TILE CEILINGATC
ASPHALTASPH
ABOVE SUSPENDED CEILINGASC
ASBESTOSASB
AMERICAN REFRIGERATION INSTITUTEARI
ARCHITECTARCH
APPROXIMATEAPPROX
APPROVEDAPPD
AMERICAN NATIONAL STANDARDS INSTITUTEANSI
ANODIZEANOD
AMPEREAMP
AMBIENTAMB
ALUMINUMALUM
ALTERNATEALT
ACTIVE LEAFA.L.
AMERICAN INSTITUTE OF STEEL CONSTRUCTIONAISC
AMPERE INTERRUPTING CAPACITYAIC
AREA INLETAI
AIR HANDLING UNITAHU
ANCHOR AHR
AGGREGATEAGGR
ABOVE FINISHED FLOORAFF
AUTOMATIC DOOR OPERATORADO
ADJACENT, ADJOINING, ADJUSTABLEADJ
ADHESIVEADH
ADDENDUMADDM
ACOUSTICAL CEILING TILEACT
ACOUSTICACST
ALUMINUM CABLE STEEL REINFORCEDACSR
ACCESS PANELACS PNL
ACCESS DOORACS DR
ACRYLIC PLASTICACR
AMERICAN CONCRETE INSTITUTEACI
ACCESSIBLEACC
ALTERNATING CURRENTAC
ABOVEABV
ANCHOR BOLTAB
AIR CONDITIONING UNITA/C UNIT
AIR CONDITIONINGA/C
ANGLEL
FRAMINGFRMG
FORGEDFRG
FRAMEFR
FIRE RESISTANT FR
FEET PER MINUTEFPM
FIREPROOFFP
FIRE PARTITIONFP
FACE OF STUDFOS
FACE OF MASONRYFOM
FACE OF FINISHFOF
FACE OF CONCRETEFOC
FENCEFN
FLUORESCENTFLUOR
FLOOR PLATEFLR PL
FLOORINGFLG
FLEXIBLEFLEX
FLOORFLR
FLASHINGFLASH
FLUSH JOINTFJT
FIXTUREFIXT
FINISH FLOORFIN FLR
FINISHFIN
FIGUREFIG
FLAT HEAD WOOD SCREWFHWS
FIRE HOSE STATIONFHS
FIRE HOSE RACKFHR
FLAT HEAD MACHINE SCREWFHMS
FIRE HOSE CABINETFHC
FLAT HEADFH
FIRE HYDRANTFH
FIBERGLASSFGL
FACTORY FINISHFF
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHER BRACKETFEB
FIRE EXTINGUISHERFE
FOUNDATIONFDTN
FIRE DAMPERFDMPR
FLOOR DRAINFD
FAN COIL UNITFCU
FLOOR CLEANOUTFCO
FLOOR CONSTRUCTION JOINTFCJ
FACINGFCG
FACE BRICKFC BRK
FOOT CANDLEFC
FIRE BRICKF BRK
FRESH AIR INTAKEFAI
FIRE APPARATUS CLOSETFAC
FRESH AIRFA
FIRE ALARMFA
FAHRENHEITF
EXTERIOREXT
EXPANSION BOLTEXP BT
EXPOSEDEXP
EXPANSIONEXP
EXISTINGEXST
EXHAUST AIREXH A
EXHAUSTEXH
EXCAVATEEXC
ENTERING WATER TEMPERATUREEWT
EMERGENCY EYE WASH & SHOWEREWS
ELECTRIC WATER COOLEREWC
ESTIMATE(D)EST
ESCALATORESCAL
EQUIPMENTEQUIP
EQUALEQ
EPOXY COATINGEPY
EXPLOSION PROOFEPRF
ELECTRICAL PANELBOARDEP
ENTRANCE, ENTERINGENTR
ENCLOSE(URE)ENCL
EMERGENCYEMER
ESTIMATED MAXIMUM DEMANDEMD
EXPANDED METAL EM
ELECTRICELEC
ELEVATION - GRADE OR BUILDINGEL
EXPANSION JOINTEJ
EACH FACEEF
ENTERING AIR TEMPERATUREEAT
EACHEA
EASTE
DIRECT EXPANSIONDX
DUMBWAITERDWTR
DRAWERDWR
DOWELSDWLS
DRAWINGDWG
DOVETAIL DVTL
DRAIN TILEDT
DOWNSPOUTDS
DOUBLE STRENGTH (GLASS)DS
DOOR CLOSERDR CL
DRAINBOARDDRB
DRAINDR
DOORDR
DOWNDN
DEMOUNTABLEDMT
DAMPERDMPR
DAMPPROOFINGDMPF
DEAD LOADDL
DIVISIONDIV
DISTRIBUTION PANELDISTR PNL
DISPENSERDISP
DISCONNECTDISC
DIMENSIONDIM
DIAGONALDIAG
DIAMETERDIA
DUCT HEATERDH
DOUBLE HUNGDH
DRINKING FOUNTAINDF
DETAILDET
DEPARTMENTDEPT
DEPRESSIONDEPR
DEMOLITIONDEMO
DEGREEDEG
DUMMY CONTROL JOINTDCJT
DOWELED CONTROL JOINTDCJ
DOUBLE ACTING DOORDBL ACT DR
DOUBLEDBL
DRY BULBDB
DATUMDAT
PENNY (AS IN NAIL - 10D)d
CYLINDERCYL
COLD WATERCW
CONDUCTIVE VINYL HOMOGENEOUS (SHEET TYPE)CVH
CEILING VENTCV
CUBIC YARDSCU YD
CABINET UNIT HEATERCUH
CUBIC FEETCU FT
COPPERCu
CONDENSING UNITCU
CENTERCTR
CENTER TO CENTERC TO C
CURRENT TRANSFORMERCT
CERAMIC TILECT
CASEMENTCSMT
COUNTERSUNKCSK
ABBREVIATIONS
LIGHTINGLTG
LIGHTWEIGHTLT WT
LIGHTLT
LAWN SPRINKLERLS
LIVING ROOMLR
LOW POINTLPT
LIGHTPROOF LOUVERLPL
LIGHTPROOF DOORLPD
LIGHTPROOFLP
LONGITUDINALLONG
LINTELLNTL
LIMESTONELMST
LUMENLM
LEAD-LINED DOORLLD
LIVE LOADLL
LOCKERLKR
LINEARLIN
LEFT HAND(ED)LH
LENGTHLG
LOADINGLDG
LOADLD
LIGHT CONTROLLC
LUMBERLBR
LABELLBL
POUNDLB
LAG BOLTLB
LAVATORYLAV
LAUNDRYLAU
LEAVING AIR TEMPERATURELAT
LAMINATELAM
LADDERLAD
LABORATORYLAB
KEYWAYKWY
KILOWATTkW
KILOVOLT AMPERES REACTIVEkVAR
KILOVOLT AMPERESkVA
KILOVOLTSkV
KICKPLATEKPL
KNOCKOUT PANELKOP
KITCHENKIT
KILOPOUND (1000 POUNDS)KIP
JOINTJT
JOISTJST
JUNCTIONJCT
JUNCTION BOXJ-BOX
JANITOR’S CLOSETJAN CLO
INSIDE PIPE SIZEI.P.S.
IRON PIPE SIZEIPS
IRON PIPEIP
INVERTINV
INTERMEDIATEINTM
INTERIORINT
INSULATIONINSUL
INSULATING FILLINSF
INCLUDEDINCL
INCINERATORINCIN
INCHIN
INTERLOCKILK
ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAIESNA
INSIDE DIAMETERID
INTERCOMIC
HERTZHz
HYDRAULICHYDR
HEATING, VENTILATING AND AIR CONDITIONINGHVAC
HEATERHTR
HEATINGHTG
HEIGHTHT
HOUSEKEEPINGHSKPG
HIGH-STRENGTH GYPSUM PLASTERHSGYP
HIGH STRENGTHHS
HOURHR
HIGH POINTHPT
HORSEPOWERHP
HIGH PRESSUREHP
HORIZONTALHORIZ
HANDRAILHNDRL
HOLLOW METALHM
HOOK(S)HK
HANDHOLEHH
HEXAGONHEX
HIGH EARLY-STRENGTH CEMENTHES
HARDWOODHDWD
HARDWAREHDW
HEADERHDR
HEAD JOINTHD JT
HARDBOARDHDBD
HEAVY DUTYHD
HEADHD
HANDICAPPEDHCP
HALON CONTAINMENT DAMPERHCD
HOLLOW COREHC
HOSE BIBBHB
GYPSUM PLASTERGYP PLAS
GYPSUM BOARDGYP BD
GYPSUMGYP
GLAZED WALL TILEGWT
GROUTGT
GLAZED STRUCTURAL UNITSGSU
GLAZED STRUCTURAL TILEGST
GRATINGGRTG
GRADE LINEGR LN
GRANITEGRAN
GYPSUM TILEGPT
GALLONS PER MINUTEGPM
GOVERNMENTGOVT
GROUNDG
GLAZED CONCRETE MASONRY UNITSGLZ CMU
GLAZINGGLZ
GLASS FIBERGLF
GLASS BLOCKGL BLK
GLASSGL
GASKET(ED)GKT
GALVANIZED IRON PIPEGIP
GALVANIZED IRONGI
GOVERNMENT-FURNISHED EQUIPMENT CONTRACTOR INSTALLEDGFE/CI
GOVERNMENT-FURNISHED EQUIPMENTGFE
GROUND FAULT CIRCUIT INTERRUPTERGFCI
GROUND FACEGF
GENERALGEN
GENERAL CONTRACTORGC
GRAB BARGB
GALVANIZED STEELGALV STL
GALVANIZEDGALV
GALLON(S)GAL
GAGEGA
NATURAL GASG
FABRIC WALL COVERINGFWC
FIRE WATERFW
FUTUREFUT
FURRINGFURG
FOOTINGFTG
FEETFT
FASTEN(ER)FSTNR
FULL SIZEFS
FIRE-RETARDANTFRT
PRESTRESSED CONCRETEPS CONC
PRESSED STEELP.S.
PIPE SPACEPS
PRESSURE-REGULATING VALVEPRV
PROJECTPROJ
PARKINGPRKG
PREFORMEDPREFMD
PREFINISHEDPREFIN
PREFABRICATE(D)PREFAB
PAIRPR
PARTS PER MILLIONPPM
POLISHED PLATE GLASSPPGL
PORTABLEPORT
PORCELAINPORC
POLISHEDPOL
PAINT(ED)PT
PANELPNL
PLYWOODPLYWD
PLATE GLASSPL GL
PILINGPLG
POUNDS PER LINEAR FOOTPLF
PLUMBINGPLBG
PLATFORMPLAT
PLASTERPLAS
PLASTIC LAMINATEPLAM
PROPERTY LINEPL
PLATEPL
POST INDICATING VALVEPIV
PREFAB ISOLATION POWER UNITPIPU
POINT OF INTERSECTIONPI
PHARMACYPHAR
PHASEPH
PERIMETERPERIM
PERFORATE(D)PERF
PEDESTALPED
PAVEMENT DRAINPD
CEMENT PLASTER (PORTLAND)PCP
POUNDS PER CUBIC FOOTPCF
PRECAST CONCRETEPCC
PIECEPC
PUSH BUTTON STATIONPBS
PARTICLE BOARDPBD
PANIC BARPB
PARALLELPAR
PUBLIC ADDRESSPA
POLEP
OBSCURE WIRED GLASSOWGL
OUTSIDE SCREW AND YOKEOS & Y
OPERATIONSOPS
OPAQUEOPQ
OPPOSITEOPP
OPENINGOPNG
OPPOSITE HANDOPH
OVALHEAD WOOD SCREWOHWS
OVALHEAD MACHINE SCREWOHMS
OVERHEADOH
OBSCURE GLASSOGL
OFFICEOFC
OUTSIDE DIAMETEROD
ON CENTER EACH WAYOCEW
ON CENTEROC
OBSERVATION WINDOWOBW
OBSCUREOBSC
OUTSIDE AIROA
NOT TO SCALENTS
NOT REQUIREDN’’REQD
NOISE REDUCTION COEFFICIENTNRC
NOISE REDUCTIONNR
NOMINALNOM
NUMBERNO
NORMALLY OPENNO
NONMETALLICNM
NEOPRENE LATEXN.L.
NAILABLENL
NOT IN CONTRACTNIC
NICKELNi
NATIONAL FIRE PROTECTION ASSOCIATIONNFPA
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNEMA
NATIONAL ELECTRICAL CODENEC
NORMALLY CLOSEDNC
NATURALNAT
NORTHN
MULLIONMULL
MOVABLEMVBL
METALMTL
METAL FURRINGMTFR
MOUNTEDMTD
MOUNTMT
METAL THRESHOLDMT
MACHINE SCREWSMS
METAL ROOF DECKINGMRD
MARBLE BASEMRB
MOP RECEPTORMR
MOVABLE PARTITIONMP
MOTORMOT
MODIFIEDMOD.
MODULARMOD
MASONRY OPENINGMO
MATERIAL NOT IN CONTRACT (INSTALLATION BY CONTRACTOR)MNIC
MILLIMETER(S)mm
MILLWORKMLWK
MOULDINGMLDG
MONOLITHICML
METAL LATHML
MISCELLANEOUSMISC
MIRRORMIRR
MINIMUMMIN
MALLEABLE IRONMI
MANHOLEMH
MATTE-GLAZED TILEMGT
MOTOR GENERATORMG
MANUFACTURERMFR
MANUFACTURINGMFG
METAL FLOOR DECKINGMFD
METAL EDGE STRIPMES
MEMBRANEMEMB
MEDIUMMED
MECHANICAL ROOMMECH RM
MECHANICALMECH
METAL DIVIDER STRIPMDS
METAL-CASED OPENINGMCO
MASONRY CONTROL JOINTMCJ
MEDICINE CABINETMC
MEMBERMBR
MACHINE BOLTSMB
MAXIMUMMAX
MATERIAL(S)MATL
MASONRYMAS
MACHINEMACH
MATCHED AND BEADEDM&B
METER(S)m
LEAVING WATER TEMPERATURELWT
LIGHTWEIGHT CONCRETELWC
LOUVERLVR
LIGHTNINGLTNG
TRUSS HEADTH
TOGGLETGL
TONGUE AND GROOVET&G
TERMINALTERM
TERRAZZOTER
TEMPORARYTEMP
TEMPERATURETEMP
TELEPHONETEL
TERRA COTTATC
TOWEL BARTB
TANGENTTAN
TREADT
SYSTEMSYS
SYNTHETICSYNTH
SYMMETRICALSYMM
SWITCHBOARDSWBD
SWITCHSW
SHEET VINYL SV
SUSPENDEDSUSP
SUBFLOORSUB FL
STAIRWAYSTWY
STRUCTURALSTRUCT
STRINGERSTR
STATIC PRESSUREST PR
STORAGESTOR
STEELSTL
SEATINGSTG
STANDARDSTD
STATIONSTA
STAINLESS STEELSST
STANDING SEAM (ROOF)SS
SERVICE SINKSS
SHELF AND RODS&R
SQUARE HEADSQHD
SQUARESQ
SPEAKERSPKR
SPACE HEATERSPH
SPECIAL FINISHSP FIN
SOUNDPROOFSPF
SPECIFICATIONSPEC
SOUNDPROOF DOORSPD
SPECIALSPCL
SPACERSPC
SHUT OFF VALVESOV
SHEET METAL SCREWSSMS
SHEET METALSM
SLEEVESLV
SEALANTSLNT
SKYLIGHTSKLT
STEEL JOIST INSTITUTESJI
SIMILARSIM
SHELVINGSHV
SHEATHINGSHTHG
SHEETSHT
SHOULDERSHLDR
SHEET GLASSSG
STRUCTURAL FACING UNITSFU
STRUCTURAL FACING TILE UNITSFTU
SAFETY GLASSSFGL
SEQUENCESEQ
SECTIONSECT
STEEL DOOR INSTITUTESDI
STORM DRAINSD
STRUCTURAL CLAY TILESCT
SCREENSCRN
SCHEDULESCHED
SOLID CORESC
SECURITY BARSS.B.
SPLASH BLOCKSB
SUPPLY AIRSA
SOUTHS
RAINWATER CONDUCTORRWC
RIVETRVT
REVERSERVS
RUBBER TILE FLOORRTF
RAISED PATTERN RUBBER TILERPRT
REVOLUTIONS PER MINUTERPM
RETRACTABLE PARTITIONRP
RIGHT OF WAYROW
ROUGH OPENINGRO
ROUNDRND
ROOMRM
RAILINGRLG
RACKRK
ROOF HATCHRH
RIGHT HANDRH
RELATIVE HUMIDITYRH
ROOFINGRFG
REVISIONREV
RETURNRET
RESILIENTRESIL
REQUIREDREQD
REMOVE(ABLE)REM
REINFORCEREINF
REGLETREG
REGISTERREG
REFRIGERATIONREFR
REFLECTREFL
REFERENCEREF
RECTIFIERRECT
RECREATION ROOMREC ROOM
RECEPTACLERECPT
RIGID INSULATIONRDG INS
ROOF DRAINRD
RECEIVERRCVR
REINFORCED CONCRETE PIPERCP
REMOTE CONTAINMENT BASINRCB
REMOTE CONTROLRC
RUBBERRBR
RUBBLE STONERBL
RUBBER BASE, RESILIENT BASERB
RETURN AIR REGISTERRAR
RETURN AIR GRILLERA GR
RABBETEDRAB
RETURN AIRRA
RISERR
RANGER
RADIUSR
QUANTITYQTY
QUARTER ROUND1/4 RND
QUARTERQTR
QUARTQT.
QUARRY TILEQT
PASS WINDOWPW
PAVINGPVG
POLYVINYL CHLORIDEPVC
PAVEDPV
PAPER TOWEL RECEPTACLEPTR
PARTITIONPTN
PAPER TOWEL DISPENSERPTD
POST-TENSIONED CONCRETEPT CONC
POINTPT.
PNEUMATIC TUBEPT
POUNDS PER SQUARE INCHPSI
POUNDS PER SQUARE FOOTPSF
YARD DRAINYD
YARDYD
TRANSFORMERXFMR
WELDED WIRE REINFORCEMENTWWR
WELDED WIRE MESHWWM
WELDED WIRE FABRICWWF
WALL TO WALLW/W
WIDTHWTH
WEIGHTWT
WAINSCOTWSCT
WASTE STACKW.S.
WATERSTOPWS
WARDROBEWRB
WASTE RECEPTACLEWR
WORKING POINTWP
WEATHERPROOFWP
WATERPROOF(ING)WP
WITHOUTW/O
WIRE MESHWM
WORK SHOPWKSH
WROUGHT IRONWI
WATT-HOUR METERWHM
WHEEL BUMPERWHB
WATER HEATERWH
WALL HUNGWH
WIRED GLASSWGL
WIDE FLANGEWF
WINDOWWDW
WASTE DISPOSERWDSP
WOOD DOORWD
WOODWD
WOOD-CASED OPENINGWCO
WHEELCHAIRW/C
WATER CLOSETWC
WOOD BLOCKINGWBL
WET BULBWB
WITHW/
WESTW
VINYL WALL COVERINGVWC
VENT THRU ROOFVTR
VOLTAGE TRANSFORMERV.T.
VENT STACKVS
VERMICULITEVRM
VAPOR RETARDERVR
VOLUMEVOL
VENEERVNR
V-JOINT(ED)VJ
VINYL HOMOGENEOUSVH
VERTICAL GRAINVG
VINYL FABRICVF
VESTIBULEVEST
VERTICALVERT
VENTILATOR(TION)VENT
VAULT DOORVD
VITRIFIED CLAY TILEVCT
VINYL COMPOSITION TILEVCT
VINYL BASEVB
VARNISHVAR
VOLTV
UNIT VENTILATORUV
UTILITYUTIL
URINALUR
UNINTERRUPTABLE POWER SUPPLYUPS
UNFINISHEDUNFIN
UNEXCAVATEDUNEX
UNDERWRITERS LABORATORIESUL
UNIT HEATERUH
UNDERGROUNDUGND
UNIT COOLERUC
TYPICALTYP
TELEVISIONTV
THERMOSTATTSTAT
TRANSVERSETRANS
TRANSOMTRANS
TOILET PARTITIONTPTN
TOILET PAPER DISPENSERTPD
TOP OF WALLTOW
TOP OF STEELTOS
TOP OF SLABTOS
TOPOGRAPHYTOPO
TOLERANCETOL
TOP OFTO
TACKSTRIPTKS
TACKBOARDTK BD
THRESHOLDTHRES
THICK(NESS)THK
DN
CONFERENCE
ROOM
OPEN OFFICE
BREAK ROOM
OD CHIEF TECH
SUPPORT
OD PROJECT
MANAGER
OD CHIEF MAINT
7'
3/
4"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
AD101
D
EM
O
LI
TI
O
N P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
E.
O M
AH
A, N E
M . B
IE
G
ER
T
M . B
IE
G
ER
T
B.
G
O R
U P
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
B.
G
O R
U
P FR
5_
PO
R _C
M .rv t
1/8" = 1'-0"1 DEMOLITION FLOOR PLAN
GENERAL NOTES
1. ALL MEASUREMENTS ARE TO BE FIELD VERIFIED
2. ANY DAMAGE RECEIVED DURING DEMOLITION OR INSTALLATION TO THE EXISTING WALL, FLOORING, OR CEILING
FINISHES TO BE PATCHED TO THE ORIGINAL STATE, MATCHING EXISTING FINISHES
3. ALL MASONRY DEMOLITION TO BE COMPLETED DURING NON-STAFFED HOURS FOR THE OFFICE. COORDINATE MASONRY
DEMOLITION TIMES WITH CONTRACTING OFFICE REPRESENTATIVE. SEE SECTION 01 30 00.24, PARAGRAPH "WORK RESTRICTIONS"
KEY NOTES
REMOVE DOOR FROM THE HINGES AND TURN OVER TO THE GOVERNMENT.
CREATE NEW OPENING IN MASONRY WALL TO FIT FRAME THAT MATCHES EXISTING DOOR PROVIDED BY THE GOVERNMENT.
FRAME IS NOT TO BE PROVIDED BY THE GOVERNMENT, BUT SHALL MATCH THE DOOR PROVIDED BY THE GOVERNMENT.
ADMIN
KEY PLAN
8'0 4' 16'
PLAN NORTH
/8
18' - 10"
1/ 2"
18' - 10"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
AD102
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
AL
A
VE
O M
AH
A, N E
M . B
IE
G
ER
T
M . B
IE
G
ER
T
B.
G
O R
U P
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
B.
G
O R
U
P FR
5_
PO
R _C
M .rv t
GENERAL NOTES
1. ALL MEASUREMENTS ARE TO BE FIELD VERIFIED.
2. ALL CEILING TILE LOCATIONS ARE TO BE FIELD VERIFIED.
3. IN THE INDICATED AREA OF DEMOLITION OF ACOUSTICAL CEILING TILE, REMOVE ANY CEILING TILE NECESSARY FOR THE INSTALLATION
OF NEW LIGHTING FIXTURES. SEE ED-101, AND ED-102 FOR SPECIFICS.
4. DURING THE REMOVAL OF CEILING TILES, SALVAGE CEILING TILES AND TURNOVER TO THE GOVERNMENT.
LEGEND:
- DEMOLITION AREA
1/8" = 1'-0"1 DEMOLITION REFLECTED CEILING PLAN
8'0 4' 16'
PLAN NORTH
KEY NOTES
REMOVE EXISTING CEILING TILES AND ASSEMBLY .1
BREAK ROOM
OD CHIEF TECH
SUPP
OD CHIEF MAINT
OD PROJECT
MANAGER
CD RE
CONFERENCE
ROOM
9'
4"
/4
8' - 0"10' - 6 7/8"
OPEN OFFICE
CD ADMIN
2' - 1 3/4"1'
0"
3'
0"
1'
0"
4'
0"
/4
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
A-101
O
FF
IC
E
FL
O
O R
P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
E.
O M
AH
A, N E
M . B
IE
G
ER
T
M . B
IE
G
ER
T
B.
G
O R
U P
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
B.
G
O R
U
P FR
5_
PO
R _C
M .rv t
1/8" = 1'-0"1 Level 1
GENERAL NOTES
1. ALL MEASUREMENTS ARE TO BE FIELD VERIFIED
2. DEMOUNTABLE PARTITIONS TO MATCH EXISTING DEMOUNTABLE PARTITIONS
3. DEMOUNTABLE PARTITIONS TO EXTEND FLOOR TO CEILING
4. DOORS, DOOR FRAMES, AND DOOR HARDWARE TO MATCH EXISTING DOOR, DOOR FRAME, AND HARDWARE
5. FLOOR FINISHES TO BE PROVIDED BY FORT RANDALL'S EXISTING STOCK FOR ANY SPOT FIXES
6. ALL MATERIALS FOR THE DEMOUNTABLE PARTITIONS AND ADMIN DESK ARE LOCATED IN THE APPENDICES.
7. ALL DOORS, AND DOOR HARDWARE FOR THE DEMOUNTABLE PARTITIONS ARE SPECIFIED IN THE DEMOUNTABLE
PARTITION QUOTE IN THE APPENDICES
8. SURFACE PREPARE AND PRIME ALL EXISTING SURFACES THAT WILL BE RECEIVEING THE NEW PAINT COATING
SYSTEM. PROVIDE PAINT TO MATCH EXISTING COLOR , TEXTURE, AND FINISH. THE PAINT COLOR IS SHERWIN WILLIAMS 6238 ICICLE. FOR THE SEMI-GLOSS FINISH USE THE THREE COAT SYSTEM CONSISTING OF PRIMER TO MEET MASTER PAINTER INSTITUTE (MPI) 50, INTERMEDIATE TO MEET MPI 54, AND A TOPCOAT TO MEET MPI 54.
9. ANY DAMAGE RECEIVED DURING DEMOLITION OR INSTALLATION TO THE EXISTING WALL, FLOORING, OR CEILING
FINISHES TO BE PATCHED TO THE ORIGINAL STATE, MATCHING EXISTING FINISHES
KEY NOTES
LEAVE EXISTING DOOR FRAME IN PLACE
INSTALL DEMOUNTABLE WALL TO INCLUDE THE DOOR ASSEMBLIES BETWEEN THE CD RE ROOM AND THE CD ADMIN ROOM.
INSTALL PROVIDED DOOR, FRAME, AND HARDWARE. PROVIDE NEW COMPATIBLE DOOR FRAME IN EXISTING MASONRY WALL AND
COORDINATE ALL DOOR HARDWARE
PROVIDE NEW DOOR, FRAME, AND HARDWARE ASSEMBLY WITHIN DEMOUNTABLE PARTITION. DOOR TO FUNCTION AS AN EMERGENCY
EXIT DOOR.
NEW WORK STATION.
PAINT ROOM WHEN THE INSTALLATION OF THE DEMOUNTABLE PARTITION IS COMPLETE. SEE GENERAL NOTE 8.
PAINT THE LENGTH OF THE WALL INDICATED ON THE DRAWING, FROM THE CORNER OF THE OFFICE UNTIL THE SLIGHT BUMPOUT AT
THE DOOR INDICATED. SEE GENERAL NOTE 8.
8'0 4' 16'
PLAN NORTH
NEW DEMOUNTABLE PARTITION
LEGEND:
OS
OSOS
OS
D ,m c
LV
,D
OS OS
OS OS
D ,m c D
,m c
RC RC R
RC
RC
J
J
F
SS
F
SS
F
SS
F
SS
ELTS
ELTS
J
ELTS
J
J21
/8
18' - 10"
1/ 2"
18' - 10"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
A-102
O
FF
IC
E
C
EI
LI
N
G P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
E.
O M
AH
A, N E
M . B
IE
G
ER
T
M . B
IG
ER
T
B.
G
O R
U P
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
B.
G
O R
U
P FR
5_
PO
R _C
M .rv t
GENERAL NOTES
1. ALL MEASUREMENTS ARE TO BE FIELD VERIFIED
2. ALL NEW CEILING WORK IS TO MATCH EXISTING CEILING MATERIALS. THE CEILING ASSEMBLY IS A SUSPENDED ACOUSTICAL
TILE CEILING TAT IS 2' x 4'.
3. SEE ED-101, ED-102, ED103 FOR NEW LIGHTING PLAN
4. SALVAGE UNBROKEN CEILING TILES AND TURN OVER TO THE GOVERNMENT.
5. IF EXISTING SUSPENSION SYSTEM HAS TO BE REMOVED ( EVEN PARTIALLY) REPLACE ALL OF THE SUSPENSION SYSTEM IN THAT ROOM.
1/8" = 1'-0"1 REFLECTED CEILING PLAN
SMOKE DETECTOR. THE LETTER "I" OR "P", IF PRESENT, STIPULATES IONIZATION OR PHOTOELECTRIC
TYPE. "U" STIPULATES UNDER RAISED ACCESS FLOOR. "D" STIPULATES A DUCT TYPE SMOKE
DETECTOR. WHERE DUCT DETECTORS ARE SHOWN IN PAIRS, LOCATIONS ARE IN SUPPLY AND RETURN DUCTS. A SINGLE DETECTOR WOULD BE INSTALLED IN THE SUPPLY DUCT IF THE LOCATION IS NOT
OTHERWISE INDICATED.
SUPPLEMENTAL FIRE ALARM LEGEND
F FIRE ALARM BELL. "SS" = SINGLE STROKE.
SS
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
FA001
FI
R
E
AL
AR
M
G
EN
ER
AL
N O
TE
S
AN
D
SU
PP
LE
M
EN
TA
L
LE
G
EN
D
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
GENERAL NOTES - FA100 THROUGH FA400 SHEETS
1 PROVIDE BACKBOX AT EACH INITIATING/DETECTION AND BELL LOCATION.
2 FINAL DEVICE LOCATIONS SHALL BE COORDINATED PRIOR TO INSTALLATION TO AVOID CONFLICTS WITH ELEMENTS FROM OTHER TRADES.
3 UNLESS OTHERWISE NOTED, ALL NON-DUCT SMOKE DETECTORS ARE MOUNTED AT FINISHED CEILING.
4 THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE FIRE ALARM
BY THE CONTRACTOR. IS GENERIC AND NOT MANUFACTURER-SPECIFIC. SCHEMATIC DRAWING IS INCOMPLETE WITH SOME DEVICES NOT SHOWN OR SEVERAL DEVICES REPRESENTING MORE. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER AND AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING INITIATING DEVICES AND NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION. PROVIDE DEVICES NOT SHOWN FOR A COMPLETE FUNCTIONAL SYSTEM LIMITED TO ADDRESSABLE MONITOR MODULES FOR ALL DEVICES THAT DO NOT HAVE ADDRESS AND CONTROL MODULES TO CONTROL AUXILIARY FUNCTIONS. PROVIDE A COMPLETE FIRE ALARM SYSTEM CONTRACTOR DESIGNED AND INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND AMENDMENTS INCLUDING BUT NOT LIMITED TO UFC 3-600-01, NFPA 70, NFPA 72, NFPA 101, SPECIFICATION 28 31 70, AND THESE DRAWINGS.
5 FOR CONFLICTS BETWEEN THE SPECIFICATION AND THE DRAWINGS, FOLLOW THE SPECIFICATION. WHERE THE DRAWINGS EXCEED REQUIREMENTS OF THE
SPECIFICATION, FOLLOW THE DRAWINGS.
6 CONNECTIONS AND SPLICES SHALL BE MADE USING TERMINAL BOXES.
7 JUNCTION BOXES, BACKBOXES, AND CONDUITS SHALL BE SURFACE MOUNTED ON PRECAST, CONCRETE, AND CONCRETE BLOCK WALLS AND STEEL
MEMBERS. JUNCTION BOXES, BACKBOXES, AND CONDUITS SHALL BE RECESS MOUNTED ON GYPSUM WALLS. COORDINATE WITH ARCHITECTURAL SHEETS.
8 WHERE SHOWN, DIMENSIONS ON FIRE ALARM DRAWINGS ARE PRELIMINARY FOR PLANNING AND BIDDING PURPOSES. CONTRACTOR IS RESPONSIBLE FOR
FINAL LOCATIONS, QUANTITIES, AND SPACING TO SATISFY OF APPLICABLE CODES, STANDARDS, UFCs, AND OTHER REQUIREMENTS IDENTIFIED IN THE
CONTRACT DOCUMENTS.
9 PLACE NEW FIRE ALARM BELLS ON EXISTING FIRE ALARM BELL CIRCUIT.
10 COORDINATE RECESS MOUNTING OF CONDUIT, BACKBOXES, DEVICES, AND EQUIPMENT WITH OTHER TRADES.
11 MOUNTING OF DEVICES SHALL COMPLY WITH NFPA AND ABA REQUIREMENTS UNLESS OTHEREWISE NOTED.
12 PLACE NEW SMOKE DETECORS ON EXISTING SMOKE DETECOR CIRCUIT.
FA401
FA402
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
FA100
O
VE
R
AL
L
FI
R E
AL
AR
M P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
1/8" = 1'-0"FA100
1 OVERALL FIRE ALARM PLAN
8'0 4' 16'
PLAN NORTH
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE FA001.
ADMIN
KEY PLAN
SS
F
SS
CD RE
CD ADMIN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
FA401
EN
LA
R G
ED
F
IR
E
AL
AR
M P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
3/8" = 1'-0"FA401
1 FIRE ALARM PLAN
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE FA001.
0 2' 4' 6'
SS
F
SS
OD CHIEF MAINT
OD CHIEF TECH
SUPP
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
FA402
EN
LA
R G
ED
F
IR
E
AL
AR
M P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
3/8" = 1'-0"FA402
1 FIRE ALARM PLAN
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE FA001.
DETECTOR
DROP CEILING TILE
J-BOX ON BOTTOM OF
ROOF DECK/STRUCTURE
CEILING MOUNTED
4"x4"x2-1/4" J-BOX
DETECTOR BASE
1/2" FLEX WITH FIRE
DETECTION CIRCUITS
"T" BAR TYPE HANGER
CONDUIT
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
FA501
FI
R
E
AL
AR
M
D
ET
AI
LS
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
N.T.S.FA501
1 DETECTOR DETAIL - DROP CEILING
MISC. FIRE ALARM
INITIATING
DEVICES
FIRE ALARM RISER DIAGRAM
ISO
ISO
M
R
M
C
FIRE ALARM
CONTROL PANEL
(FACP)
LTG ROOM CONTROLLER
INTERIOR AUDIBLE
NOTIFICATION DEVICES
2 3
# KEY NOTES
1. CONNECT NEW SMOKE DETECTORS ON EXISTING SMOKE DETECTOR CIRCUITRY.
2. CONNECT NEW AUDIBLE NOTIFICATION DEVICES ON THE EXISTING INTERIOR AUDIBLE NOTIFICATION APPLIANCE CIRCUITRY.
3. MAXIMUM NUMBER OF NOTIFICATION AND INITIATING DEVICES PER CIRCUIT SHALL BE IN ACCORDANCE WITH THE CONTROL PANEL LIMITATIONS. CONDUCTOR INTEGRITY MONITORING IS REQUIRED. PROVIDE NEW CIRCUITRY ROUTED BACK TO THE FACP IF EXISTING CIRCUIT DOES NOT HAVE CAPACITY TO SUPPORT ADDITIONAL NOTIFICATION OR INITIATING DEVICES.
4. PROVIDE SIGNAL TO CD ADMIM ROOM CONTROLLERS AND CONTACTOR(S) TO OVERRIDE LOCAL CONTROLS AND ACTIVATE EGRESS LIGHTING WHILE FIRE ALARM SYSTEM IS IN ALARM STATE. COORDINATE WITH LIGHTING CONTROLS (EL500 SERIES).
PROVIDE SEPARATE RELAY TO EACH ROOM CONTROLLER AND CONTACTOR.
GENERAL NOTES
1. RISER IS A DIAGRAMMATIC REPRESENTATION OF THE FIRE ALARM SYSTEM AND IS NOT CONSIDERED COMPLETE.
INCOMPLETENESS IS SHOWN FOR CLARITY. SEE FIRE ALARM PLANS FOR LOCATIONS OF INITIATING DEVICES AND NOTIFICATION APPLIANCES. PROVIDE DEVICES FOR A COMPLETE FUNCTIONAL SYSTEM NOT LIMITED TO ADDRESSABLE MONITOR MODULES FOR ALL DEVICES THAT DO NOT HAVE ADDRESS AND CONTROL MODULES TO CONTROL AUXILIARY FUNCTIONS.
2. REFER TO FIRE ALARM/MASS NOTIFICATION FLOOR PLANS AND SPECIFICATIONS FOR PRELIMINARY QUANTITY AND
LOCATIONS OF INDICATION AND NOTIFICATION DEVICES.
3. REFER TO THE FIRE ALARM AND MASS NOTIFICATION SPECIFICATIONS FOR ADDITIONAL INTERFACE REQUIREMENTS
BETWEEN THE FIRE ALARM AND MASS NOTIFICATION SYSTEMS.
4. SEE FA001 AND SPECIFICATION 28 31 70 FOR ADDITIONAL FIRE ALARM NOTES.
F
SS
M
F
SS
EXISTING CIRCUITRY
NEW CIRCUITRY
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
FA502
FI
R
E
AL
AR
M
R
IS
ER
D
IA
G
R
AM
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
10" 0
10" 0 10" 0
10" 0
10" 0
6" 0
14" 0
8" 0
8" 0
12" 0
12" 0
8" 0
8" 0
8" 0
10" 0
10" 0
SD-3SD-3
SD-3 SD-3
SD-3
SD-3
SD-2
SD-2
SD-1
SD-1
SD-1
SD-5
SD-1
SD-4
RG-2
SD-2
SD-2
DH-1
X
6" 0
6" 0 6" 0
SD-5
14" 0
SD-5
14" 0
SD-5
X
RG-1
DH-214 X 7
SD-2
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
16 X 7
T
RR-1
T
RR-1
PARTIAL PLAN - ELEV. 1291.0
12" 0 5'
SCALE: INCH = 1 FOOT
E
E
12" 0 5'
SCALE: INCH = 1 FOOT
RG-1
10" 0
RG-1
10" 0
T
12" X 12"
DH-3
14" 0
MECHANICAL DEMOLITION GENERAL NOTES
REPLACED WITH NEW PER ARCHITECTURAL NEW WORK PLAN.
SALVAGED FOR LATER REINSTALLATION UNLESS OTHERWISE TO BE
AND ACCESSORIES REMOVED DURING THE WORK SHALL BE
CEILING TILES, CEILING GRID, WALL MOLDINGS, CEILING HANGERS
CONDITIONS.
CHANGED FROM THAT SHOWN ON THIS SHEET. FIELD VERIFY EXACT
LOCATION OF EXISTING WALLS AND ROOM DESCRIPTIONS HAVE
DEMOLITION WORK.
ETC. ARE APPROXIMATE. FIELD VERIFY PRIOR TO BEGINNING
LOCATION OF EXISTING DUCTWORK, DIFFUSERS, RETURN GRILLES,
TO BE REMOVED AND DISPOSED SHOWN IN GREEN.
EXISTING ITEMS TO REMAIN SHOWN IN HALF TONE (GRAY) AND ITEMS 1.
2.
3.
795 CFM
4.
BREAKROOM
MECHANICAL KEY NOTES
LAY-IN CEILING TYPE SUPPLY AIR DIFFUSER SD-5.
REMOVE AND DISPOSE OF EXISTING 14" FLEXIBLE DUCT AND 24" X 24" 1.
A N
S
P
W E
R H
O U
S E
P R
IV
A
T E
O F
F
IC
E R
E N
O V
A T
IO
N
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
Q
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
IC
T
IL
E
N U
M B
E R
F
IL
E N
A M
E
J
S W
E R
C Z
E K
C H
A N
IC
A
L D
E M
O L
IT
IO
N P
L A
N
MD101
K
P A
R K
J
S W
E R
C Z
M
D
.d g n
P A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
10" 0
10" 0 10" 0
10" 0
10" 0
6" 0
8" 0
8" 0
12" 0
12" 0
8" 0
8" 0
8" 0
10" 0
10" 0
SD-3SD-3
SD-3 SD-3
SD-3
SD-3
SD-2
SD-2
SD-1
SD-1
SD-1
SD-3
SD-1
SD-4
RG-2
SD-2
SD-2
DH-1
X
6" 0
6" 0 6" 0
SD-5
14" 0
SD-5
14" 0
SD-5
X
RG-1
DH-214 X 7
SD-2
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
16 X 7
T
RR-1
T
RR-1
PARTIAL PLAN - ELEV. 1291.0
12" 0 5'
SCALE: INCH = 1 FOOT
E
E
12" 0 5'
SCALE: INCH = 1 FOOT
RG-1
10" 0
RG-1
10" 0
T
DH-3
ROOM
BREAK
TECH SUPP
OD CHIEF
MAINT
OD CHIEF
MANAGER
OD PROJECT
ROOM
CONFERENCE
14" 0
CD RE OFFICE
ADMIN
MECHANICAL NEW WORK GENERAL NOTES
SPECIFICATION SECTION 23 31 13.00 40.
FOR METAL DUCT AND SEAL REQUIREMENTS, REFER TO
23 07 00.
FOR INSULATION REQUIREMENTS, REFER TO SPECIFICATION SECTION
TO INSTALL NEW AIR DIFFUSER AND GRILLES IF NECESSARY.
PROVIDE ADDITIONAL CEILING GRID SYSTEM AND HANGERS IN ORDER
WORK PLAN.
OTHERWISE TO BE REPLACED WITH NEW PER ARCHITECTURAL NEW
HANGERS AND ACCESSORIES SHALL BE REINSTALLED UNLESS
SALVAGED CEILING TILES, CEILING GRID, WALL MOLDINGS, CEILING
NEW MECHANICAL ITEMS TO BE INSTALLED SHOWN IN RED.
DEMOUNTABLE WALLS AND ASSOCIATED DOORS SHOWN IN BLUE, AND
EXISTING ITEMS TO REMAIN SHOWN IN HALF TONE (GRAY), NEW 1.
2.
3.
MECHANICAL KEY NOTES
07 00.
EACH SPACE. INSULATE DUCTWORK PER SPECIFICATION SECTION 23
DEG ELBOWS. INSTALL WITH PERFORATED TRANSFER AIR GRILLE IN
PROVIDE NEW 12" X 12" RETURN AIR TRANSFER DUCT WITH TWO (2) 90
BETWEEN THE DIFFUSER AND WYE BRANCH. (TYP. OF 2)
DIFFUSER SD-3. PROVIDE 10" FACTORY INSULATED FLEXIBLE DUCT
WITH ADJUSTABLE VENT COVER) LAY-IN CEILING TYPE SUPPLY AIR
PROVIDE NEW 24" X 24" (NECK SIZE-10" Ø - 4 WAY -PERFORATED FACE
EXISTING 14" Ø OPENING. PROVIDE AIRTIGHT SEAL AT JOINTS.
GALVANIZED STEEL BULLHEAD ROUND WYE BRANCH CONNECTED TO
PROVIDE NEW 14" X 10" X10" ASTM A653 CS TYPE B HOT DIPPED 1.
SD-312 X 12
2.
3.
4.
ADJUSTABLE VENT COVER
PHOTO 1. AN EXAMPLE OF EXISTING 24" X 24"
OPEN OFFICE OPEN OFFICE
OPEN OFFICE
5.
A N
S
W E
R H
O U
S E
P R
IV
A
T E
O F
F
IC
E R
E N
O V
A T
IO
N
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
Q
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
J
S W
E R
C Z
C H
A N
IC
A
L N
E W
W O
R K
P L
A N
M-101
K
P A
R K
J
S W
E R
C Z
M
-1
.d
P A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
N.T.S. N.T.S.
M1 M2
VENT COVER
ADJUSTABLE
VENT COVER
ADJUSTABLE
(ACCEPTABLE ALTERNATIVE)
MAX. 4FT
A N
S
W E
R H
O U
S E
P R
IV
A
T E
O F
F
IC
E R
E N
O V
A T
IO
N
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
Q
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
J
S W
E R
C Z
T A
IL
S
M-501
K
P A
R K
J
S W
E R
C Z
M
-5
.d
P A
EXISTING LIGHTING FIXTURE. LOCATION IS APPROXIMATE.
SUPPLEMENTAL DEMOLITION LEGEND
EXISTING EMERGENCY LIGHTING FIXTURE. LOCATION IS APPROXIMATE.
EXISTING LIGHTING FIXTURE. LOCATION IS APPROXIMATE.
EXISTING EMERGENCY LIGHTING FIXTURE. LOCATION IS APPROXIMATE.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
ED001
EL
EC
TR
IC
AL
D
EM
O
LI
TI
O N
N O
TE
S
AN
D
SU
PP
LE
M
EN
TA
L
LE
G
EN
D
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
KEYNOTES - ED100 THROUGH ED400 SHEETS
1 APPROXIMATE LOCATION OF EXISTING SMOKE DETECTOR WHICH IS TO BE KEPT IN PLACE.
2 APPROXIMATE LOCATION OF EXISTING SPRINKLER WHICH IS TO BE KEPT IN PLACE.
3 PROTECT FIXTURE IN PLACE. REMOVE EXISTING BATTERY BACKUP AND EXISTING CIRCUIT FROM FIXTURE. RE-WIRE EXISTING CIRCUIT TO BYPASS THIS
FIXTURE.
4 PROTECT FIXTURE IN PLACE. REMOVE EXISTING CIRCUIT FROM FIXTURE. RE-WIRE EXISTING CIRCUIT TO BYPASS THIS FIXTURE.
2 2
2 2
2 2
CD OFFICE
OD OFFICE
OPEN OFFICE
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
ED100
O
VE
R
AL
L D
EM
O
LI
TI
O N
P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
1/8" = 1'-0"ED100
1 OVERALL DEMOLITION PLAN
0 2' 4' 6'
PLAN NORTH
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE ED001.
ADMIN
KEY PLAN
ELECTRICAL DEMOLITION PLAN LEGEND
1 REMOVE INTERIOR LIGHTING FIXTURES, CONDUITS, CONDUCTORS, BOXES, AND OTHER-LIGHTING RELATED EQUIPMENT NOT LISTED HERE, UNLESS OTHERWISE NOTED.
LUMINAIRE TYPE DESIGNATION (SEE SCHEDULE AND DETAILS)
FIXTURE UNIQUE IDENTIFIER FOR AIMING PURPOSES (IF PRESENT)
SWITCH DESIGNATION (IF PRESENT)
CIRCUIT IDENTIFICATION (IF PRESENT)
A2,BA1
LP1-1,a
'3'
'p'
'4' 'a'
'mc'
'wp'
LOW VOLTAGE OCCUPANCY SENSOR, CEILING MOUNTED UNLESS OTHERWISE INDICATED.
SINGLE POLE 20A SWITCH. SUBSCRIPT (WHERE PRESENT) DENOTES THE FOLLOWING:
LOW VOLTAGE SWITCH. SUBSCRIPT (WHERE PRESENT) DENOTES THE FOLLOWING:LV
'bi' BI-LEVEL SWITCH. PROVIDE TWO TOGGLE SWITCHES SIDE BY SIDE IN A SHARED JUNCTION
BOX. SEE LIGHTING FIXTURE SCHEDULE AND KEYED NOTES ON PLANS INDICATING
SWITCHED BALLAST DESIGNATIONS PER FIXTURE ("a" or "b").
S
WEATHERPROOF (GASKETED) SWITCH.
PILOT LIGHT SWITCH.
SWITCH CONTROLLING MATCHING LETTERED FIXTURES (TYPICAL, SINGLE LOWER CASE
LETTERS).
FOUR-WAY SWITCH.
THREE-WAY SWITCH.
'D' DIMMER SWITCH.
SWITCH ID. WHERE MULTIPLE SWITCHES SHARE THE SAME ID, THE CONTROLLED AREAS
AND FUNCTIONS ARE IDENTICAL.
MOMENTARY CONTACT SWITCH. LETTER (WHERE PRESENT) DENOTES SWITCH
CONTROLLING MATCHING LETTERED FIXTURES.
'K' KEY SWITCH.
EMERGENCY ("E") LIGHTING FIXTURES
ELTS EMERGENCY LIGHTING TRANSFER SWITCH.
##E
'maint' MAINTAINED CONTACT TOGGLE SWITCH.
'R' RED SWITCH HANDLE.
'UB' LABEL SWITCH "UNCLEAN BEACONS".
'MUSH' MUSHROOM STYLE PUSHBUTTON.
SYMBOL DENOTES GENERAL TYPE OF LUMINAIRE
OS
aS
SUPPLEMENTAL LIGHTING LEGEND
##E
R RELAY CONNECTION TO THE FIRE ALARM PANEL.
ROOM CONTROLLERRC
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
EL001
LI
G
H
TI
N G
N O
TE
S
AN
D
S U
PP
LE
M
EN
TA
L
LE
G
EN
D
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
KEYNOTES - EL100 THROUGH EL400 AND EL510 SHEETS
1 EXTEND EXISTING CIRCUIT 10L-42 TO EMERGENCY FIXTURES AND NEW EXIT SIGNS.
2 PROVIDE SWITCHES IN COMMON ENCLOSURE AT LOCATIONS INDICATED ON PLANS.
3 FIRE ALARM NOTIFICATION SYSTEM PANEL DRY CONTACT ACTUATES "HOLD-ON" DURING FIRE ALARM.
4 FIRE ALARM DRY CONTACT CONNECTION IS ONLY REQUIRED IN THE CD ADMIN ROOM. HOLD-ON WIRING IS TO BE CAPPED FOR THE OTHER ROOMS.
5 EXTEND TO EXISTING CIRCUIT 10L-39.
6 CONNECT TO NEW EMERGENCY FIXTURE AND EXIT SIGN CIRCUIT.
7 JUNCTION BOX REPRESENTS THE CONNECTION FROM AN UNSWITCHED POINT OF EXISTING CIRCUIT 12LA-9 TO AN ELTS.
#GENERAL NOTES - EL100 THROUGH EL400 SHEETS
1 COORDINATE RECESS MOUNTING OF CONDUIT, BACKBOXES, DEVICES, AND EQUIPMENT WITH OTHER TRADES.
2 INTERIOR LIGHT FIXTURES IN ROOMS WITH DIMMER SWITCHES SHALL HAVE DIMMING BALLASTS AND SHALL WORK IN CONJUNCTION WITH THE OCCUPANCY
SENSOR AND/OR WALL SWITCHES IN THE ROOM.
3 EACH LIGHTING BRANCH CIRCUIT HOME RUN SHALL CONSIST OF MINIMUM 2-#12, #12G CONDUCTORS IN MINIMUM 3/4" CONDUIT UNLESS OTHERWISE NOTED.
ENTIRE CIRCUIT SHALL BE SAME SIZE AS HOME RUN SIZE INDICATED UNLESS OTHERWISE NOTED.
4 LIGHT SWITCHES SHOWN SIDE-BY-SIDE ON THE PLANS SHALL BE INSTALLED IN A SINGLE MULTI-GANG BOX UNLESS OTHERWISE INDICATED.
5 JUNCTION BOXES, DEVICES, BACKBOXES, ASSOCIATED CONDUIT, ETC., LOCATED ON STEEL MEMBERS, PRECAST CONCRETE, CONCRETE, AND CONCRETE
BLOCK WALLS SHALL BE SURFACE MOUNTED. JUNCTION BOXES, DEVICES, BACKBOXES, ASSOCIATED CONDUIT, ETC., SHALL BE RECESS MOUNTED ON
GYPSUM WALLS, UON. COORDINATE WITH ARCHITECTURAL SHEETS.
6 INTERIOR EMERGENCY FIXTURES SHALL BE SWITCHED BY THE LOCAL SWITCHING DEVICE IN THE ROOM AND SHALL HAVE AUTOMATIC TESTING CAPABILITY.
UPON LOSS OF POWER, EMERGENCY FIXTURES SHALL BYPASS THE LOCAL SWITCHING DEVICE AND TURN ON AUTOMATICALLY.
7 LIGHTING FIXTURES ARE CONTROLLED BY SWITCHING DEVICE WITHIN SAME ROOM OR AREA, UON.
8 ALL EGRESS ZONE LIGHT FIXTURES CONTROLLED BY AN OCCUPANCY SENSOR MUST COMPLY WITH NFPA 101 SECTION 7.8.1.2.2. FIRE ALARM INTERFACE TO
HOLD ON THE LIGHTS MAY BE MADE AT THE ROOM CONTROLLER OR THE ELTS.
9 WIRELESS CONTROLS SHALL NOT BE USED.
10 OCCUPANCY SENSOR AND VACANCY SENSOR LAYOUT IS CONCEPTUAL ONLY AND IS SHOWN FOR COVERAGE INTENT ONLY. CONTRACTOR TO DETERMINE
ACTUAL QUANTITY AND LOCATIONS WITHIN EACH ROOM PER MANUFACTURER'S INSTRUCTION.
11 LINE VOLTAGE AND LOW VOLTAGE WIRING SHALL BE PROVIDED IN SEPARATE CONDUITS/RACEWAYS.
12 DO NOT PENETRATE STRUCTURAL COLUMNS, BEAMS, AND TRUSSES. AFIX DEVICES AND RACEWAY WITH BEAM C-CLAMPS, BRACKETS, CLIPS, UNISTRUT, AND OTHER NON-PENETRATING AND NON-ADHESIVE HARDWARE.
13 CONDUIT AND CONDUCTOR SIZES LISTED ARE MINIMUM SIZES. CIRCUITS MAY BE COMBINED INTO COMMON CONDUIT. CONTRACTOR IS RESPONSIBLE FOR
RESIZING CONDUITS PER NFPA 70 FILL RATIO AND CURRENT-CARRYING CONDUCTOR/TEMPERATURE DERATING REQUIREMENTS.
EL401
EL402
EL403
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
EL100
O
VE
R
AL
L
LI
G H
TI
N
G P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
1/8" = 1'-0"EL100
1 OVERALL LIGHTING PLAN
8'0 4' 16'
PLAN NORTH
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE EL001.
OS
OSOS
OS
D ,m c
LV
,D
RC
RC
RJ
ELTS
C2 C2E
C2C2
C2 C2E
12LA-11
10L-42 6
CD RE
CD ADMIN
ROOM
CD RE
LIGHTING CONTROLS MATRIX NOTES:
1. IN THE EVENT OF A FIRE ALARM EVACUATION SIGNAL, TURN ON FIXTURES AND INCREASE LIGHT
OUTPUT TO FULL OPERATION. HOLD ALL LIGHTS AT FULL ON OUTPUT FOR DURATION OF
EVACUATION SIGNAL.
2. CONTROLLED RECEPTACLES TO COORDINATE WITH RELEVANT OCCUPANCY SENSORS SO THAT
APPROPRIATE RECEPTACLES POWER OFF AND ON ACCORDINGLY.
CONTROL FUNCTION
AU
TO
M
AT
IC
O
N T
O
0% V
IA
O
C C
U P A
N C
Y
SE
N
SO
R
M
AN
U
AL
O
FF
A T
SW
IT
C H
M
AN
U
AL
O N
T O
L
EV
EL
S
ET
B
Y
SW
IT
C
H
AU
TO
M
AT
IC
O
FF
A
FT
ER
M
IN
O F
N O
O C
C U
PA
N
C Y
R O
O M
H
AS
R
EC
EP
TA
C
LE
C O
N
TR
O L S
. S
EE
N O
TE
FI
R
E
AL
AR
M
E
VA
C U
AT
IO
N S
IT
U
AT
IO
N . S
EE
N
O
TE
M
AN
U
AL
D
IM
M
IN
G C
O N
TR
O
LS
P
R O
V I D
ED
A
T
SW
IT
C
H
A B C D E F G
CD ADMIN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
EL401
EN
LA
R G
ED
L
IG
H
TI
N
G P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
3/8" = 1'-0"EL401
1 LIGHTING REFLECTED CEILING PLAN
0 2' 4' 6'
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE EL001.
OS OS
OS OS
D ,m c D
,m c
RC
RC
J
C2 C2 C2
C2 C2 C2
12LA-11
OD CHIEF MAINT
OD CHIEF TECH
SUPP
ROOM
OD CHIEF MAINT
LIGHTING CONTROLS MATRIX NOTES:
1. IN THE EVENT OF A FIRE ALARM EVACUATION SIGNAL, TURN ON FIXTURES AND INCREASE LIGHT
OUTPUT TO FULL OPERATION. HOLD ALL LIGHTS AT FULL ON OUTPUT FOR DURATION OF
EVACUATION SIGNAL.
2. CONTROLLED RECEPTACLES TO COORDINATE WITH RELEVANT OCCUPANCY SENSORS SO THAT
APPROPRIATE RECEPTACLES POWER OFF AND ON ACCORDINGLY.
CONTROL FUNCTION
M
AN
U
AL
O
FF
A T
SW
IT
C H
M
AN
U
AL
O N
T O
L
EV
EL
S
ET
B
Y
SW
IT
C
H
AU
TO
M
AT
IC
O
FF
A
FT
ER
M
IN
O F
N O
O C
C U
PA
N
C Y.
O M
H
AS
R
EC
EP
TA
C
LE
C O
N
TR
O L S
. S
EE
N O
TE
M
AN
U
AL
D
IM
M
IN
G C
O N
TR
O
LS
P
R O
V I D
ED
A
T
SW
IT
C
H
A B C D E
OD CHIEF TECH SUP
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
EL402
EN
LA
R G
ED
L
IG
H
TI
N
G P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
3/8" = 1'-0"EL402
1 LIGHTING REFLECTED CEILING PLAN
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE EL001.
ELTS
J
ELTS
J
XW2
XW1
12LA-9
10L-39
12LA-9
10L-42
OPEN OFFICE
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
EL403
EN
LA
R G
ED
L
IG
H
TI
N
G P
LA
N
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
1/8" = 1'-0"EL403
1 LIGHTING PLAN
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE EL001.
BLACK
RED
CLASS 2 WIRING DESIGNATIONS
BLUE
BLUE/WHITE
YELLOW
ORANGE
YELLOW/ORANGE
DC RETURN
POWER (24VDC)
OCCUPANCY: AUTO-ON / AUTO-OFF
OCCUPANCY: MANUAL-ON / AUTO-OFF
HOLD-ON
HOLD-OFF
LOCAL SWITCH INPUT
BROWN
GREEN
BROWN/WHITE
DRY CONTACT NC (NORMALLY CLOSED)
DRY CONTACT COMMON
DRY CONTACT NO (NORMALLY OPEN)
HVAC WIRING DESIGNATIONS
YL
W
O R
N O
R N
/Y
LW
BL
U
BL
U
/W H
T G
R N
BR
N
/W H
T
BR
N R
ED
BL
K
RED (LINE)
RED (LOAD)BLK
WHT
WHITE (NEUTRAL)
POWER PACK
HOT
WHTNEUTRAL
RECEPTACLE
LOAD
RED (LINE)
RED (LOAD)
WHITE (NEUTRAL)
YL
W
O R
N O
R N
/Y
LWBL
U
BL
U /W
H T
G R
N
BR
N /W
H T
BR
N
R
EDBL
K
LOAD
0-10V
DIMMING
DRIVER
NEUTRAL
HOT
WHT
OCCUPANCY
SENSOR
TO EMERGENCY AND OTHER
LOADS (WHERE APPLICABLE)
ROOM CONTROLLER
OCCUPANCY
SENSOR
SIGNAL VIA FACP
FIRE ALARM
EGRESS RELAY
(TYP)
LOW VOLTAGE
DIMMING ONLY
CONTROL
ZONE SWITCH
MOMENTARY
SWITCH
WHITE (NEUTRAL)
SENSOR SWITCH
RED (LOAD)
DESCRIPTION OF OPERATION:
AUTO ON VIA SENSOR SWITCH.
DIMMING CONTROL FUNCTION.
MANUAL/AUTO OFF VIA SENSOR SWITCH.
NEUTRAL
LOAD
HOT
WHT
TO EMERGENCY AND OTHER
LOADS (WHERE APPLICABLE)
WHITE (NEUTRAL)
SENSOR SWITCH
RED (LOAD)
DESCRIPTION OF OPERATION:
MANUAL ON VIA SENSOR SWITCH.
DIMMING CONTROL FUNCTION.
MANUAL/AUTO OFF VIA SENSOR SWITCH.
NEUTRAL
LOAD
HOT
WHT
TO EMERGENCY AND OTHER
LOADS (WHERE APPLICABLE)
1 2 3 4 5 6 7 1 2 3 4 5 6 7
GTD20A
ELECTRONICS
COVER
GTD20A TERMINAL
BLOCKS
LOCAL
SWITCHING
MEANS
EMERGENCY
LIGHTING
LOAD UP
TO 20A
HOT
NEUTRAL
EMERGENCY
SOURCE
HOT
NEUTRAL
HOT
NEUTRAL
NORMAL
CKT BKR
PANEL
T1 T2
NOTE: BODINE GTD20A RELAY DEVICE OR EQUAL FOR CONTROL OF POWER TO FIXTURES WITH EXTERNAL EMERGENCY SUPPLY IN LIEU OF INTEGRAL EMERGENCY DRIVER/BALLAST/BATTERY. UNDER NORMAL CIRCUMSTANCES, RELAY SHALL BE CONTROLLED BY SWITCH ON WALL AND NORMAL POWER. IN THE EVENT OF A POWER OUTAGE, RELAY SHALL BYPASS TOGGLE SWITCH CONTROL AND SUPPLY POWER FROM THE EMERGENCY
SOURCE.
INSTALL PER MANUFACTURER RECOMMENDATION. LOCATE RELAY ABOVE CEILING NEAR SWITCH. UNLESS NOTED
OTHERWISE.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
LE
N
AM
E:
EL510
LI
G
H
TI
N G
C O
N
TR
O L
D
ET
AI
LS
O M
AH
A
D
IS
TR
IC
T
C
AP
IT
O L
AV
EN
U E
O M
AH
A, N E
T.
R
IC
H
LI
N
G
T.
R
IC
H
LI
N
G
D . O
TT
ER
BY
/1
3/
W
F2
3Q
PO
W
ER
H
O U
SE
P
R
IV
AT
E
O
FF
IC
E
R
EN
O
VA
TI
O
N
FO
R T
R
AN
D
AL
L D
AM
, S
O U
TH
D
AK
O
TA
S.
L
IN
D
G R
EN FR
5_
PO
R
_E .rv t
N.T.S.EL510
POWER PACK
WIRING DESIGNATIONS
N.T.S.EL510
MULTIPLE CIRCUITS UTILIZING
COMMON CONTROL DEVICES WITH
FIRE ALARM HOLD ON
N.T.S.EL510
WALL SWITCH
OCCUPANCY SENSOR
N.T.S.EL510
WALL SWITCH
VACANCY SENSOR
N.T.S.EL510
EMERGENCY LIGHTING CONTROL RELAY
DETAIL FOR CENTRAL EMERGENCY SOURCE
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYNOTES SEE EL001.
GENERAL NOTES - EL500 SHEETS
1 MAXIMUM NUMBER OF SENSORS PER ROOM CONTROLLER MAY VARY BETWEEN MANUFACTURERS.
2 DO NOT CONNECT THE RED (+24VDC) WIRES TOGETHER ACROSS ROOM CONTROLLERS.
3 OCCUPANCY AND VACANCY SENSOR SHUT OFF DELAY IS 15 MINUTES, UON.
4 THE ROOM CONTROLLER GRACE PERIOD IS (MIN. 15 SECONDS, MAX 60 SECONDS) FOR “MANUAL ON” OPERATION WHEREBY
THE LOAD TURNS OFF WHEN THE SENSOR TIME DELAY EXPIRES, THEN THE LOAD TURNS BACK ON IF OCCUPANCY SENSOR INPUT IS TRIGGERED DURING THE GRACE PERIOD. USE THE MOMENTARY CONTACT SWITCH TO TURN THE LOAD ON IF THE
GRACE PERIOD EXPIRES WITH NO SENSOR INPUT.
5 ROOM CONTROLLER UNDER AUTO ON/OFF WITH OVERRIDE SWITCH FUNCTION: ONCE THE LOAD IS TURNED OFF USING THE MOMENTARY CONTACT SWITCH, THE POWER PACK DOES NOT TURN THE LOAD ON UNTIL AFTER THE SENSOR TIME DELAY EXPIRES. PRESS THE MOMENTARY CONTACT SWITCH BEFORE THE SENSOR TIME DELAY EXPIRES TO TURN THE LOAD ON, AND WHEN THE OCCUPANCY SENSOR’S TIME DELAY EXPIRES, THE POWER PACK REVERTS TO AUTO ON OPERATION.
6 OVERRIDE THE AUTOMATIC OFF FUNCTIONS USING INPUTS ON THE “HOLD ON” LINE. ALSO, OVERRIDE THE MANUAL OFF
STATE AT THE TIME OF “HOLD ON” INITIATION USING “HOLD ON” INPUTS.
7 PROVIDE ROOM CONTROLLER WITH FAIL-SAFE CIRCUITRY WHEREBY THE CONTACTS FAIL IN THE CLOSED POSITION IN THE
EVENT OF POWER FAILURE OR MALFUNCTION.
8 USE FULLY COMPATIBLE LIGHTING CONTROLS INCLUDING DIMMING BALLASTS/DRIVERS, DIMMING SWITCHES, AND
OCCUPANCY SENSORS.
9 MOUNT ROOM CONTROLLER AND POWER PACKS ABOVE THE CEILING IMMEDIATELY IN FRONT OF THE DOOR WHERE CEILING SPACE IS ACCESSIBLE. IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SENSOR MANUFACTURER USE SINGLE OR DOUBLE GANG POWER PACK BOXES. MOUNT POWER PACKS IN A RECESSED SWITCH BOX WHERE CEILING IS INACCESSIBLE. PLACE POWER PACKS WALL BOXES SIX INCHES FROM INSIDE CORNER OF THE ROOM AND 46 INCHES ABOVE FINISHED FLOOR. PERMANENTLY ENGRAVE “OCCUPANCY SENSOR POWER PACK” ON THE BOX FACEPLATE.
10 CONTROL WIRE COUNTS ARE NOT SHOWN ON LIGHTING PLANS. CONSULT LIGHTING CONTROL FUNCTIONAL DIAGRAMS AND
MANUFACTURER REQUIREMENTS FOR GUIDANCE.
11 QUANTITY OF FIXTURES, SENSORS, POWER PACKS, AND OTHER DEVICES IS NOT REPRESENTED IN THESE DIAGRAMS.
PROVIDE QUANTITY OF DEVICES SHOWN (MINIMUM) OR AS REQUIRED. MAXIMUM NUMBER OF SENSORS PER POWER PACK
MAY VARY BETWEEN MANUFACTURERS.
12 BRANCH CIRCUIT(S) TO EMERGENCY BALLAST IN FIXTURES ARE NOT SHOWN TO COMPLETION IN THESE DIAGRAMS.
PROVIDE CONDUCTORS FROM THE BRANCH CIRCUIT TO THE FIXTURES WITH EMERGENCY BALLASTS OR DRIVERS WITHOUT ROUTING THROUGHOUT FIXTURE SWITCHING, TIMER, OCCUPANCY CONTROLS, OR DAYLIGHTING CONTROLS.
13 PROVIDE CONDUIT RACEWAY FOR ALL WIRING.
14 SUBMIT SHOP DRAWINGS WITH LIGHTING CONTROL DIAGRAMS FOR THE ACTUAL MANUFACTURER’S DEVICES PROVIDED, AND REVISE THE LIGHTING CONTROL DIAGRAMS “AS-BUILT”.
15 ADDITIONAL POWER PACKS MAY BE REQUIRED FOR LONG MOMENTARY CONTACT SWITCH LOW VOLTAGE CIRCUITS. VERIFY
MAXIMUM LOW VOLAGE CIRCUIT LENGTH WITH MANUFACTURER.
16 PROVIDE CONDUIT RACEWAY FOR ALL WIRING. PROVIDE LOW VOLTAGE CONTROL RACEWAY SYSTEM SEPARATE FROM
120V AND/OR 277V RACEWAY SYSTEM.
17 DIM TO MINIMUM PHOTOSENSOR DIMMING CONTROLS. DO NOT DIM CONTROLS TO OFF.
18 DO NOT USE WIRELESS CONTROLS.
19 THE LIGHTING CONTROL FUNCTIONAL DIAGRAMS SHOW ONE METHOD OF ACCOMPLISHING THE LIGHTING CONTROL
STRATEGIES INTENDED FOR EACH SPACE OR ZONE. ALTERNATE METHODS ARE ACCEPTABLE ONLY IF THERE IS NO LOSS OF FUNCTIONALITY AS DESCRIBED BY THE LIGHTING CONTROL FUNCTIONAL DIAGRAMS AND THE CONTRACT SPECIFICATIONS. SUBMIT TO THE GOVERNMENT FOR EVALUATION AND APPROVAL A DETAILED DESCRIPTION INDICATING HOW THE PROPOSED ALTERNATE METHODS SATISFY THE CONTRACT DOCUMENTS. GOVERNMENT APPROVAL IS NEEDED FOR INSTALLATION TO PROCEED. PROCUREMENT PENDING GOVERNMENT APPROVAL IS AT RISK FOR THE CONTRACTOR.
DIRECT/INDIRECT LED TROFFER
REVISED: APRIL 2016 NL-1LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, WITH ONE-PIECE LOWER REFLECTOR HAVING
TEXTURED, HIGH REFLECTANCE, WHITE POLYESTER POWDER-COATED FINISH. OPTIONAL
SIZES OF 1FT x 4FT, 2FT x 2FT, AND 2FT x 4FT AVAILABLE.
2. LIGHT SOURCE - UPWARD-FACING LEDS WITH DIFFUSE LENS TO ELIMINATE DIRECT VIEW OF
LIGHT SOURCE. LED BOARD OR ARRAY WITH MINIMUM 50K HOURS RATED LIFE AT L70. COLOR
TEMPERATURE, EFFICACY, COLOR RENDERING INDEX, MAXIMUM INPUT POWER, AND MINIMUM
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE. MAXIMUM BINNING TOLERANCE
OF A 4-STEP MCADAM ELLIPSE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION.
STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED IN LUMINAIRE SCHEDULE.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED WITH
EMERGENCY BATTERY BACK-UP. IC RATED WHEN INDICATED.
6. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
7. SKETCHES ARE NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY
MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN
MANUFACTURER OR PREFERENCE.
3.5"
NOMINAL
TYPE C2
RCR
CU
Note: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
TYPE XW1, XW2
EXIT SIGN
REVISED: NOVEMBER 2020 NL-28LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM OR HIGH-IMPACT, UV-STABILIZED, INJECTION-MOLDED
THERMOPLASTIC.
2. LIGHT SOURCE - SOLID STATE LEDS.
3. DRIVER - INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING
VOLTAGE OF 120/277V, THERMAL MANAGEMENT, AND < 20% THD.
4. CERTIFICATION - NFPA 101, UL LISTED FOR DAMP OR WET LOCATION, AND ROHS
COMPLIANT.
5. MOUNTING - SURFACE MOUNTED ON CEILING AND/OR WALL.
6. OPTIONS - RED LETTERING, ONE- OR TWO-SIDED. ELU REMOTE HEAD CAPABILITIES.
BATTERY BACKUP.
Note: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .