GP_Service_Switchgear_and_Transformer_Replacement_BCOE_photo_attachments.pdf
PDF 10 MB Posted
- Attached to
- Station Service Upgrade and Transformer Replacement Federal contract opportunity
- Solicitation number
- W9128F-16-Q-0130
About this file
Additional pictures
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF30_AMD002.pdf | ||
| Gavins_Reference_Dwgs_Amendment.pdf | ||
| PPQ.pdf | ||
| Q A.pdf | ||
| AK-1-25_cubicle_(3).JPG | JPG image | |
| AK-1-25_cubicle_(3).JPG | JPG image | |
| IMG_1856.jpg | JPG image | |
| IMG_1855.jpg | JPG image | |
| IMG_1863.jpg | JPG image | |
| AK-1-25_cubicle_(1).JPG | JPG image | |
| AK-1-25_cubicle_(2).JPG | JPG image | |
| IMG_1862.jpg | JPG image | |
| IMG_1861.jpg | JPG image | |
| AK-1-50_Nameplate.JPG | JPG image | |
| 16-Q-0130.pdf | ||
| SS_Upgrade_specs.pdf | ||
| W9128F-16-Q-0130.pdf | ||
| Gavins_Point_Station_Service_Upgrades_Contract_Drawings.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDEX TO PHOTOGRAPHS
1. El. 1179.5 Looking up through hatch
2. EL. 1179.5 - Looking toward doorway way to switchgear gallery. Note HVAC height limitations will limit ability to move transformer to switchgear gallery fully assembled
3. EL. 1179.5 - Looking through doorway to switchgear gallery toward erection bay. Note height limitations for moving transformer fully assembled into position
4. El. 1179.5 - Switchgear Gallery looking toward erection bay. Cable trays containing feeder cables on right
5. EL. 1179.5 - Control cable trays behind 480 V switchgear
6. El. 1161 – Typical conduits underneath 480 VAC switchgear used for routing the feeder cables to the cable trays located on upstream wall of EL. 1179.5
7. EL. 1179.5 – Typical conduit penetrations into the bottom of the 480 volt switchgear for feeder cables to exit to floor below.
8. Nameplate existing Main and Tie breakers
9. Nameplate existing Feeder breakers
10. El. 1179.5 - Existing transformers and 480 V switchgear line-up
11. El. 1179.5 - 13.8 KV transition section. Transformer is to the left.
12. El 1179.5 - Typical 480 V bus transition from transformer to 480 volt switchgear. Rear view of the 480 volt switchgear. Transformer to left
Note: These photographs are being provided for information only. The Contractor is responsible for verifying all equipment, routing and limitations in the field.
El. 1179.5 Looking up through hatch
EL. 1179.5 - Looking toward doorway way to switchgear gallery. Note HVAC height limitations will limit ability to move transformer to switchgear gallery fully assembled
EL. 1179.5 - Looking through doorway to switchgear gallery toward erection bay. Note height limitations for moving transformer fully assembled into position
El. 1179.5 - Switchgear Gallery looking toward erection bay. Cable trays containing feeder cables on right
EL. 1179.5 - Control cable trays behind 480 V switchgear
El. 1161 – Typical conduits underneath 480 VAC switchgear used for routing the feeder cables to the cable trays located on upstream wall of EL. 1179.5
EL. 1179.5 – Typical conduit penetrations into the bottom of the 480 volt switchgear for feeder cables to exit to floor below.
Nameplate existing Main and Tie breakers
Nameplate existing Feeder breakers
El. 1179.5 - Existing transformers and 480 V switchgear line-up
El. 1179.5 - 13.8 KV transition section. Transformer is to the left.
El 1179.5 - Typical 480 V bus transition from transformer to 480 volt switchgear. Rear view of the 480 volt switchgear. Transformer to left