Gavins_Point_Station_Service_Upgrades_Contract_Drawings.pdf
PDF 5 MB Posted
- Attached to
- Station Service Upgrade and Transformer Replacement Federal contract opportunity
- Solicitation number
- W9128F-16-Q-0130
About this file
Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF30_AMD002.pdf | ||
| PPQ.pdf | ||
| Gavins_Reference_Dwgs_Amendment.pdf | ||
| Q A.pdf | ||
| GP_Service_Switchgear_and_Transformer_Replacement_BCOE_photo_attachments.pdf | ||
| IMG_1861.jpg | JPG image | |
| AK-1-50_Nameplate.JPG | JPG image | |
| AK-1-25_cubicle_(1).JPG | JPG image | |
| AK-1-25_cubicle_(2).JPG | JPG image | |
| IMG_1862.jpg | JPG image | |
| AK-1-25_cubicle_(3).JPG | JPG image | |
| AK-1-25_cubicle_(3).JPG | JPG image | |
| IMG_1856.jpg | JPG image | |
| IMG_1855.jpg | JPG image | |
| IMG_1863.jpg | JPG image | |
| 16-Q-0130.pdf | ||
| W9128F-16-Q-0130.pdf | ||
| SS_Upgrade_specs.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NN
X
X
X
X
X
X
X
X
X
XX
X
NN
NN
GAVINS POINT DAM POWERHOUSE
STATION SERVICE SWITCHGEAR
UPGRADE & TRANSFORMER REPLACEMENT
MISSOURI RIVER - NEBRASKA
Omaha District of Engineers
US Army Corps
S W
Y D
G P
P -1 .0
-0 -0 /1
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
S
E V
E N R
M
IL
E S P .E
G P
P .0
G -0
X X
X .d g n
G
H D
C D
K
L
C A
T
IO
N A
N D V
IC
IN
IT
Y M
A P
G-001
P O
W E
R H
O U
S E
M
IS
S O
U R I
R
IV
E R
W F -1
-Q
-0
G A
V
IN
S P
O
IN
T D
A M
A N
S I
D
/0
/2
G
H D
C J P
R
G
H D
C D
M T
:1
S S S
W G
R X
F M
R R
E P
LEWIS & CLARK LAKE
NEBRASKA
CEDAR CO.
KNOX CO.
RADIO TOWER SPILL
WAY
PLANT
POW
ER
CREST RD.
DAKOTA
SOUTH
TRAINING DIKE RD
FACILITY
FISH CLEANING
WELL
PICNIC AREA
F L
O W
CENTER
VISITOR
AREA 1
PICNIC
AREA 3
PICNIC
STOR. BLDG.
SHOP &
ROOM
REST
AREAPUBLI
C
USE
SOUTH
SHORE
BOUNDARY
PROJECT
STA.
DISPOSAL
SANITARY
LAGOON
YARD
MAINT.
AREA 2
PICNIC
RAMP SWIMMING AREA
WELL
HOUSE
CHANGE
TOE RD.
RAMP
M
IS
S O
U R I R
IV
E R
T A
IL
W A
T E
R A
R E
A
CAMP LOOP 1
REST ROOM
CAMP LOOP 2
LOCATION MAP
NEBRASKAB
A
Z
IL
E
FL
O
W
SPRINGFIELD
S A
N D
S N
A T
C H
C R
C R
C R
C H
A R
L
IE
C R
TABOR
POINT DAM
GAVINS
YANKTON
CR.
BEAVER
CROFTON
W E
IG
A N
D
C R
LEWIS & CLARK LAKE
SOUTH DAKOTA
RAMP
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/1
/2
BORDER VERSION UPDATE [09-2012]
G-001SHEET NAME:g2hdcdmt Daniel M. TrowbridgeBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 8/16/2016 10:29:47 AM
D R
A W
N B
Y
C H
E C
K E
D B
Y
OMAHA DISTRICT
GAP-1.03_G-002XXX.DGN
GAP-1.03_G-001XXX.DGN
G-002
G-001
E-601
E-201
E-102
E-101
E-001
GAP-1.03_E-601XXX.DGN
GAP-1.03_E-201XXX.DGN
GAP-1.03_E-102XXX.DGN
GAP-1.03_E-101XXX.DGN
GAP-1.03_E-001XXX.DGN
480 VAC ONE LINE DIAGRAM INSTALL
480 VAC SWITCHGEAR ELEVATION VIEW INSTALL
PLAN 1179.5 & 1181
PLAN EL 1195
TRANSVERSE SECTION
INDEX TO DRAWINGS
PROJECT LOCATION AND VICINITY MAP
GAP-1.03-0-0/2
GAP-1.03-0-0/1
GAP-1.03-6-1/2
GAP-1.03-6-1/1
GAP-1.03-6-0/3
GAP-1.03-6-0/2
GAP-1.03-6-0/1
E V
E N R
M
IL
E S P .E
W F -1
-Q
-0
P .0
G -0
X X
X .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
IN
D
E X T
O D
R A
W
IN
G S
G-002
P O
W E
R H
O U
S E
M
IS
S O
U R I
R
IV
E R
G P
P -1 .0
-0 -0 /2
G A
V
IN
S P
O
IN
T D
M
INDEX TO DRAWINGS
GENERAL
ELECTRICAL
REFERENCE DRAWINGS
NO.
SHEET
FILE NUMBER CADD FILE NAME TITLE FILE NUMBER TITLE
S S S
W G
R X
F M
R R
E P
L
/0
/2
G
H D
C J P
R
G
H D
C D
M T
:1
A N
S I
D
G
H D
C D
K
MG72-84E117.9
MG72-84E108.6
MG72-84E107.5
MG72-84E106.2
MG72-84E105.3
MG72-84E104.2
MG72-83E142.3
MG72-83E138.2
MG72-83E137.2
MG72-83E119.3
MG72-83E111.1
MG72-83E110.1
MG72-83E108.1
MG72-83E102.7
MG66-83E108.1
MG51-83E158.4
MG51-83E157.5
MG51-83E156.7
MG51-83E149.5
MG51-83E148.6
HK-207
HK-186
HK-177
HK-177 R3
HK-176-R2
HK-176 R2
HK-175 R4
ERECTION BAY CENTER PORTION FLOOR EL.1195.0 ARCHITECTURAL.pdf
GEN, SERVICE & ERECTION BAY FLR EL.1179.5 & EL.1181.0 ARCHITECTURAL.pdf
SERVICE AND ERECTION BAYS FLOOR EL.1161.0 ARCHITECTURAL.pdf
SERVICE BAY FLOOR EL.1134.0 ARCHITECTURAL.pdf
LONGITUDINAL SECTIONS ARCHITECTURAL SHEET 2.pdf
LONGITUDINAL SECTIONS ARCHITECTURAL SHEET 1.pdf
CABLE TRAYS SPILLWAY TUNNEL.pdf
CABLE TRAY ARRANGEMENT SHEET 2.pdf
CABLE TRAY ARRANGEMENT SHEET 1.pdf
13.8KV SWITCHGEAR AND 460V STATION SERVICE SWITCHGEAR.pdf
ANNUNCIATOR SCHEDULE SHEET 2.pdf
ANNUNCIATOR SCHEDULE SHEET 1.pdf
CONTROL SCHEMATICS STATION SERVICE.pdf
460V AC ONE LINE DIAGRAM.pdf
CONTROL SCHEMATICS STATION SERVICE.pdf
CONDUIT AND GROUNDING ERECTION BAY - EL. 1179.5 SHEET 3.pdf
CONDUIT AND GROUNDING ERECTION BAY - EL. 1179.5 SHEET 2.pdf
CONDUIT AND GROUNDING ERECTION BAY - EL. 1179.5 SHEET 1.pdf
CONDUIT AND GROUNDING ERECTION BAY - EL. 1195 SHEET 2.pdf
CONDUIT AND GROUNDING ERECTION BAY - EL. 1195.0 SHEET 1.pdf
REAR VIEW & DTLS 125VDC & 115VAC 1 PH DIST SWBD & MAIN LTG PNL.pdf
SCHEMATIC WIRING DIAGRAM STATION SERVICE.pdf
WIRING DIAGRAM 460 VOLT STATION SERVICE SWITCHGEAR.pdf
WIRING DIAGRAM 460 VOLT STATION SERVICE SWITCHGEAR .pdf
460V STATION SERVICE SWITCHGEAR.pdf
ASSEMBLY AND FOUNDATION 460V STATION SERVICE SWITCHGEAR.pdf
BUSING AND DETAILS 460V STATION SERVICE SWITCHGEAR .pdf
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/1
/2
BORDER VERSION UPDATE [09-2012]
G-002SHEET NAME:g2hdcdmt Daniel M. TrowbridgeBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 8/16/2016 10:29:57 AM
D R
A W
N B
Y
C H
E C
K E
D B
Y
EL.1234.0
INTAKE DECK
MAXIMUM DESIGN FLOOD EL.1221.60
ANCHORS FOR FLOATING CRAFT
MAXIMUM OPERATING POOL EL.1210.0
NORMAL POWER POOL EL.1208.0
MINIMUM POWER POOL EL.1203.5
LIMIT OF DRAWDOWN EL.1195.0
DE-ICER NOZZLES
EL.1139.5
INTAKE FLOOR
TRASHRAKE
HANDRAIL
LADDER
DEVICE
GATE DOGGING
FEEDRAIL
T R
A S
H R
A C
K G
U
ID
E
B U
L K
H E
A D G
A T
E G
U
ID
E
L A
D D
E R R
U N
G S
S E
R V
IC
E G
A T
E G
U
ID
E
AIR VENTS
CAVITY WALL
3'-0"
35'-0"29'-0"
R10 + 52.25
L UNITS
CORRIDOR
GUARD RAIL
MAIN LTG. PANEL
D.C. PANELS &
WINDOW
OBSERVATION
C
250 TON CRANE
L GENERATOR BAY
CTROLLEYTROLLEY
TRASH RACK
BULKHEAD GATE
GATE
SERVICE
LINER
TURBINE PIT
NOSE
PIER
EL.1157.0
L DISTRIBUTORC
PIEZOMETER TIPS
EL.1097.0
(80 TON)
INTAKE GANTRY CRANE
JIB HOIST
64'-0" C TO C CRANE RAILS
FLOW
TOP OF PARAPET EL.1263.75
CEILING
SUSPENDED
ROOM
SUPPLY
TOP OF PARAPET EL.1263.75
(25TON)
GANTRY CRANE
DRAFT TUBE
SHELVES
EL.1211.0
MAIN CONTROL SWBD'S
DRAFT TUBE ACCESS MANHOLE
SWGR & SPRD'G ROOM
EL.1195.0
EL.1179.5
EL.1179.5
COMPRESSOR ROOM
L A
D D
E R
EL.1179.0
HANDRAIL
GATE DOGGING DEVICE
ANCHORS FOR FLOATING CRAFT
EL.1161.0
EL.1134.0
AIR RECEIVER ROOM
RECEIVER
FUTURE AIR
EL.1135.0
RUNNER
DRAIN
16" SPIRAL CASE
ACCESS STAIRS
SPIRAL CASE
NOSING
STEEL PIER
DRAFT TUBE
DRAIN
4" VALVE WELL
UNWATERING DRAIN
18" DRAFT TUBE
LADDER RUNGS
EL.1143.0
DRAFT TUBE GATE GUIDES
DRAFT TUBE GATE
TAILRACE PAVING SLAB
EL.1110.38
87'-0"91'-6"
LINEUP
SWITCHGEAR
480 VAC
15 KV AND
E V
E N R
M
IL
E S P
F -1
-Q
-0
P .0
E -0
X X
X .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
T R
A N
S V
E R
S E S
E C
T
IO
N
E-001
P O
W E
R H
O U
S E
M
IS
S O
U R I
R
IV
E R
G P
P -1 .0
-6 -0 /1
G A
V
IN
S P
O
IN
T D
A M
TRANSVERSE SECTION THRU C OF UNITL
/0
/2
G
H D
C J P
R
G
H D
C D
M T
:1
A N
S I
D
S S S
W G
R X
F M
R R
E P
L
G
H D
C
NOTES:
1. TRANSVERS VIEW SHOWS ELEVATIONS FOR WORK AND ACCESS.
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/1
/2
BORDER VERSION UPDATE [09-2012]
E-001SHEET NAME:g2hdcdmt Daniel M. TrowbridgeBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 8/16/2016 10:30:04 AM
D R
A W
N B
Y
C H
E C
K E
D B
Y
DOOR
ROLL UP
MAIN
HATCH
GEN HRG
NEW DIESEL
PLAN EL. 1195.00
C
DN UP
JOINT
CONTRACTION
JOINT
CONTRACTION
JOINT
CONTRACTION
TRASH RACK
SHOP
ELECTRIC
MACHINE SHOP REPAIR PIT
UPPER GRATE
SHAFT
ELEV.
ROOM
SHOWER
SHAFT
AIR INTAKE
TOILET
ROOM
ERECTION
OBSERVATION WINDOW
L UNIT 2 STA. 20+03.0
DNDN
AIR COOLERS
GENERATOR
SUPPORT BEAMS
GENERATOR HOUSING
ACTUATOR
GENERATOR ROOM
GATE
BULKHEAD
ACCESS
INSPECTION
GATE
SLOPE
GATE
SERVICE
BEARING BRACKETS
TOILET:MEN
VESTIBULE
GUARD
LOUNGE
TEL
LOBBY
FOUNTAIN
DRINKING
CLO'S
JAN
WOMEN
DISPLAY ROOM
C L
O S
ROOM
AID
FIRST
KITCHEN
ROOM
DARK CONTROL ROOM
FILES
DESK
CORRIDORMOTOR GEN. ROOM
FUTURE
ROOM
BATTERYRM
CURR
CAR
TEL &
REPAIRS
BATTERY
RM
STOR
ELECT.
RM
GEN
DIESEL
DRAFT TUBE DECK - EL.1179.0
TRACKS
TRANSFER
TRANSFORMER
L OF UNITSC
L UNIT 3 STA. 20+83.0CCL UNIT STA. 19+23.0
NOTES:
NOTE 1
D.C. BOARDS
RECORDER BOARD
INSTRUMENT & RELAY BOARDS
PANEL
CONTROL
DIESEL
4. HATCH SHOWN FOR ACCESS ONLY AND NOT TO BE REPLACED.
EXISTING SWITCHGEAR. APPROXIMATE LENGTH IS 240 FT.
TRAY W6 AND CONDUITS 4P33 AND 4P33A BETWEEN HRG AND
3. EDG-c1-SQ1 TO BE 7C/#12 AWG INSTALLED IN EXISTING CABLE
CONTROL CABINET TO ADJACENT HRG.
2. EDG-q1-HRG TO BE 3C/#10 AWG ROUTED FROM DIESEL GENERATOR
REMOVAL OF EXISTING SWITCHGEAR.
1. ACCESS TO ELEVATIONS 1179.5 AND 1181 FOR INSTALLATION &
23' 3"
/0
/2
G
H D
C D
K
G P
P -1 .0
-6 -0 /2
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
H
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
E V
E N R
M
IL
E S P .E
A N
S I
D G
P P .0
E -1
X X
X .d g n
G
H D
C J P
R
G
H D
C D
M
A N E
L .0
E-101
:1
S
W G
R X
F M
R R
E P
L
P O
W E
R H
O U
S E
M
IS
S O
U R I
R
IV
E R
W F -1
-Q
-0
V
IN
S P
O
IN
T D
A M
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/1
/2
BORDER VERSION UPDATE [09-2012]
E-101SHEET NAME:g2hdcdmt Daniel M. TrowbridgeBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 8/16/2016 10:30:11 AM
D R
A W
N B
Y
C H
E C
K E
D B
Y
L UNIT 1 STA. 19+23.0C CL UNIT 2 STA. 20+03.0 CL UNIT 3 STA. 20+83.0
WATER PUMP
GEN. COOLING STRAINER
RAW WATER
R A
M P
OIL PRESSURE TANKS
UNITS
AIR HANDLING
R A
M P
EL.1181.0
TURBINE FLOOR
CYLINDERS
CO
FRAME
VALVE
R A
M P
UP
TRASHRACK
BULKHEAD GATE
SERVICE GATE
CONTRACTION JOINT AIR VENTS
TANKS
OIL PRESSURE
SWGR 11
SWGR 12 UNIT
AIR HANDLING
UPDN CUBICLES
EXCITATION
CUBICLES
EXCITATION
SWGR 2
SWITCHGEAR AND SPREADING ROOM EL. 1179.5
ACCESS MANHOLE
DRAFT TUBE
DRAFT TUBE GATE SLOT
SWGR 13
VENT SHAFT
TURBINE PIT
AIR CONDITIONING ROOM EL.1179.5
480 V SWITCHGEAR
FROM EL 1195
HATCH OUTLINE
8'-6"
STATION SERVICE TRANSFORMERS.
ELEVATION 1181
TURBINE FLOOR
E V
E N R
M
IL
E S P
F -1
-Q
-0
P .0
E -1
X X
X .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
P L
A N E
L .5
.0
E-102
P O
W E
R H
O U
S E
M
IS
S O
U R I
R
IV
E R
G P
P -1 .0
-6 -0 /3
G A
V
IN
S P
O
IN
T D
A M
PLAN EL. 1179.5 & 1181.0
/0
/2
G
H D
C J P
R
G
H D
C D
M T
:1
A N
S I
D
S S S
W G
R X
F M
R R
E P
L
G
H D
C
ASSEMBLED AT FINAL LOCATION OF THE NEW TRANSFORMERS.
3. THE TRANSFORMER ENCLOSURES TO BE DESIGNED TO BE FIELD
2. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS.
BY EXISTING HVAC DUCTING OF APPROXIMATELY 82 INCHES.
1. ACCESS TO SWITCHGEAR AND SPREADER ROOM IS HEIGHT LIMITED
A
E-201
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/1
/2
BORDER VERSION UPDATE [09-2012]
E-102SHEET NAME:g2hdcdmt Daniel M. TrowbridgeBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 8/16/2016 10:30:18 AM
D R
A W
N B
Y
C H
E C
K E
D B
Y
REFERENCE DRAWINGS:
SHUNT
TRIP
GROUND BUS
V
VS
480-120V
XQ02
V
VS
480-120V
A1
A1
1A 6A
S T
A T
IO
N S
E R
V
IC
E T
R A
N S
F O
R M
E R
S T
A T
IO
N S
E R
V
IC
E
T
R A
N S
F O
R M
E R
11A
NAMEPLATE SCHEDULE
NAMEPLATE SCHEDULE
NAMEPLATE SCHEDULE
V
VS
LT1LT2 LT3
PB1
DETAIL B
DOOR FRAME 1B & 11B
DETAIL A
DOOR FRAME 1A& 11A
LT4 LT5
P1 P2
P4P3
SS1 SS2
NAMEPLATE SCHEDULE DETAIL A NAMEPLATE SCHEDULE DETAIL B
MT1
PB2
SEE DETAIL A
SEE DETAIL A
SEE DETAIL B
HK-177-R3
DRAWING NO. TITLE
STATION SERVICE SWITCHGEAR
WIRING DIAGRAM 460 VOLT
NO.
ITEM
LINE
FIRST
LINE
SECOND
1A
BUS #2
BUS #2
BUS #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
FEEDER #2
SWGR #17 MACHINE SHOP FEEDER
SWGR #22 TRANS YARD & SWYD
SWGR #19 AIR COMPRESSORS
NO.
ITEM
NAMEPLATE LETTERING
V
VS
LINE
FIRST
LINE
SECOND
PHASE C
GROUND DETECTED
LT1
LT2
LT3
PB1
VOLTMETER
GROUND TEST
GROUND DETECTED PHASE A
GROUND DETECTED
PHASE B
VOLTMETER480V BUS
NO.
ITEM
NAMEPLATE LETTERING
6A
LINE
FIRST
LINE
SECOND
BREAKERBUS TIE
DIESEL GENERATOR
NO.
ITEM
NAMEPLATE LETTERING
P1
P2
P3
LINE
FIRST
LINE
SECOND
TESTER & METER
P4
AMMETER
LT4
LT5
HORN
GROUND CURRENT
GROUND FAULT INDICATOR
HIGH RESISTANCE GROUND CONTROL MODULE
GROUND FAULT INDICATION
INDICATIONSYSTEM NORMAL
SS2
PB2
GROUND PULSE
GROUND TEST
MT1
SS1
HORN TEST
NO.
ITEM
LINE
FIRST
LINE
SECOND
BUS #1
BUS #1
BUS #1
11A METERING & RELAYING
STATION SERVICE MAIN
FEEDER #1
FEEDER #1
FEEDER #1
FEEDER #1
FEEDER #1
FEEDER
FEEDER #1
FEEDER
FEEDER #1
FEEDER #1
SELECT SWITCH
SELECT SWITCH
SELECT SWITCH
A
AMMETER
PUSH BUTTON
PUSH BUTTON
GROUND CURRENT
FEEDER #1
FEEDER #1
FEEDER #1
SEE DETAIL B
XQ01
XQ03
1B
17 16 15 14
13121110
9 8 7 6
6B1B
6B
11B
BUS #2 NAMEPLATE LETTERING BUS #1 NAMEPLATE LETTERING
11B
14 15 16 17
13 12 11 10
6 7 8 9
5 4 3 2
UNDER THIS CONTRACT. MOUNT PER SPEC SECTION 13 48 00.00 26
2. BOTH STATION SERVICE TRANSFORMERS TO BE REPLACED
1. ITEMS IN BOLD INDICATE EQUIPMENT TO BE INSTALLED OR MODIFIED
SWGR #20 CHILLER FEEDER #2
PPCS UPS NORMAL FEEDER
PPCS UPS EMERGENCY FEEDER
WASTE WATER TREATMENT FEEDER
FEEDER #1SWGR #20 CHILLER
SWGR #14 MISC POWER
SWGR #31 AIR CONDITIONING
DIESEL GENERATOR
SWGR #16 SUMP PUMPS
SWGR #15 INTAKE
MAIN LIGHTING PANEL
SWGR #12 UNIT #2 AUX PNL
SPARE
SWGR #13 UNIT #3 AUX PNL
SWGR #11 UNIT #1 AUX PNL
DAM & SPILLWAY
HIGH RESISTANCE GROUND
STATION SERVICE MAIN
METERING & RELAYING
SWGR #13 UNIT #3 AUX PNL
SWGR #22 TRANS & SWYD
SWGR #19 AIR COMP
SWGR #15 INTAKE
SWGR #12 UNIT #2 AUX PNL
SWGR #18 OIL PUMPS & PUR
MAIN LIGHTING PANEL
SWGR #16 SUMP PUMPS
SWGR #11 UNIT #1 AUX PANEL
SWGR #14 MISC POWER
DAM & SPILLWAY
POWERHOUSE CRANE
SWGR #31 AIR CONDITIONING
HIGH RESISTANCE GROUND
E V
E N R
M
IL
E S P .E
W F -1
-Q
-0
P .0
E -2
X X
X .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
E-201
P O
W E
R H
O U
S E
M
IS
S O
U R I
R
IV
E R
G P
P -1 .0
-6 -1 /1
G A
V
IN
S P
O
IN
T D
A M
V
A C S
W
IT
C H
G E
A R
E L E
V A
T
IO
N V
IE
W
IN
S T
A L L
G
H D
C J
R
/0
/2
:1
A N
S I
D
S S S
W G
R X
F M
R R
E P
L
G
H D
C D
M T
G
H D
C D
K
E-102
A N.T.S.
ELEVATION VIEW & SINGLE LINE DIAGRAM
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/1
/2
BORDER VERSION UPDATE [09-2012]
E-201SHEET NAME:g2hdcdmt Daniel M. TrowbridgeBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 8/16/2016 10:30:25 AM
D R
A W
N B
Y
C H
E C
K E
D B
Y
150150350150225300300225300300400150600225225225
/0
/0
/0
/0
/0
M C
M
M C
M
/0
M C
M
M C
M
/0
/0
M C
M
225225600150400300300225300300225100150350150
/0
/0
M C
M
M C
M
M C
M
/0
/0
M C
M
/0
M C
M
-3
M C
M
/0
ANN.
52-2
ACB TRIP
F
VR
VS V
GEN
EXC.
3-400/5 A
500MCM
1-400/5
A
VS
DEVICES
PROTECTIVE
SHUNT TRIP
125V-DC
DIESEL DRIVEN
480V-30 275KVA
ELECTRICAL INTERLOCK (NOTE 1)
52-3
VS
ANN.
ACB TRIP
52-1
STATIONS
TRIP
SAFETY
13,800/480V
1000KVA, 3 O,
TRANSFORMER NO. 2
STATION SERVICE
13,800/480V
1000KVA, 3 O,
TRANSFORMER NO. 1
STATION SERVICE
REFERENCE DRAWING
NOTES:
MG72-830102
B R
ID
G E C
R A
N E
S W
G R
F
D R
S W
G R
F
D R
F E
E D
E R
D
A M S
P
IL
L W
G R
F
D R
A
IR
C
O N
D H
E A
T
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
M A
IN
L
IG
H T
IN
G
F
D R
M A
IN
L
IG
H T
IN
G F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
S W
G R
F
D R
F E
E D
E R
D
A M S
P
IL
L W
A Y
YY
BA
BA
BA
GROUND
RESISTANCE
HIGH
ZIG-ZAG
800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800
10 14 17 9 4 15 16 5 13 12 8 6 7 2 3 18 3 7 6 2 8 13 12 5 11 16 15 4 9 17 14 10
3 PH 480 VAC Bus #23 PH 480 VAC Bus #1
SJ1 SJ2
VV
Y
Y
Y
Y
HRGHRG
3C#10
P P
C S U
P S N
O R
M A
L
/0
S P
A R
E
W A
S T
E W
A T
E R T
R T
M N
T
P P
C S U
P S E
M E
R G
/0
/0
S W
G R
F
D R
S W
G R
F
D R
C -5
M C
M
TO NEW HRG CABINET (REFER TO E-101).
MOUNTED IN THE GENERATOR CONTROL PANEL ADJACENT
6. DIESEL HRG LINE CONNECTION TO BE MADE AT BREAKER
EXISTING SYSTEM FUNCTIONALITY.
BETWEEN NEW AND EXISTING EQUIPMENT TO MAINTAIN
5. FIELD VERIFY ALL CONNECTION POINTS FOR INTERCONNECTION
EXISTING BUS GROUND ALARM POINTS.
4. HRG BUS GROUND ALARMS TO BE CONNECTED TO THE
CORRESPONDING PROTECTED BUS.
CONTROL POWER FOR, OR BE DERIVED FROM, THE
3. HRG CONTROL POWER TO BE CONNECTED TO THE 125 VDC
2. ALL BREAKERS TO BE EQUIPPED WITH BELL ALARM CONTACTS
TWO OF THE THREE CAN BE CLOSED AT ANY ONE TIME.
1. MAIN AND TIE BREAKERS ARE INTERLOCKED SUCH THAT ONLY
E V
E N R
M
IL
E S P .E
W F -1
-Q
-0
P .0
E -6
X X
X .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
E-601
P O
W E
R H
O U
S E
M
IS
S O
U R I
R
IV
E R
G A
V
IN
S P
O
IN
T D
A M
G
H D
C J P
R
O N
E L
IN
E D
IA
G R
A M
G P
P -1 .0
-6 -1 /2
V
A C S
Y S
T E
M
/0
/2
G
H D
C D
M T
IN
S
T A
L L
:1
A N
S I
D
S S S
W G
R X
F M
R R
E P
L
G
H D
C D
K
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/1
/2
BORDER VERSION UPDATE [09-2012]
E-601SHEET NAME:g2hdcdmt Daniel M. TrowbridgeBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 8/16/2016 10:30:32 AM
D R
A W
N B
Y
C H
E C
K E
D B
Y
| GPP1.03_G-001XXX |
| GPP1.03_G-002XXX |
| GPP1.03_E-001XXX |
| GPP1.03_E-101XXX |
| GPP1.03_E-102XXX |
| GPP1.03_E-201XXX |
| GPP1.03_E-601XXX |