14_W9128A-17-B-0001-Drawings.pdf
PDF 6 MB Posted
- Solicitation number
- W9128A-17-B-0001
About this file
Drawings 14
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
K A
W
A -1
-C -0
X
A -1
-B -0
R E
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N D
Y
J U
N E
.1
X
S C
P
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
ABOVE
ROOF LINE
D
D
13'-0"2'-4"
60'-8"
12'-8"
10'-8"
5'-0" 9'-4"
20'-2"
15'-4"
6'-0" 5'-6"
12'-6" 11'-6" 8'-6"
25'-6"
3'-4"
9'-8"
AT 16" O.C. TYP.
4" METAL STUDS
AT 16" O.C. TYP.
2" METAL FURRING
6'-0" 4'-0" 18'-0" 4'-0"4'-0" 9'-4"
107109
B
A
C
B
A A A
A
A-101OB A-501OB
A-101OB A-501OB
A-101OB A-501OB
F.E.C.
F.E.C.
F.E.C.
E.W.C.
6'-8"
17'-4"
B
A-101OB A-731OB
C
A-101OB A-731OB
A
A-101OB A-731OB
B A
A-901
5'-4"
15'-4"
13'-2"
3'-4"
6'-0" 4'-0" 4'-0"
2'-8"
DETAIL D ON SHEET A-140
SPLASHBLOCK SEE
D E
F A-901
A
A-101OB A-421OB
MH
N
A-101OB A-701OB
C
A-901
2'-0"D
A-101OB A-731OB
E
A-101OB A-731OB
F
A-101OB A-731OB
SHELVING
G F
G I
PANEL
ACCESS
A/A-101OB
SEE ELEV
EA. SIDE -
HANDRAIL
R A
M P D
O W
N
JOINTS.
3. SEE STRUCTURAL SHEETS FOR MASONRY CONTROL
OFFICE LOCATIONS.
CORNERS OF GYPSUM WALLBOARD CORNERS IN
2. PROVIDE CORNER GUARDS AT ALL EXTERIOR
CIVIL SHEETS FOR THE ACTUAL ELEVATIONS.
BUILDING ELEVATIONS REFERENCE ONLY, SEE
1. FINISH FLOOR ELEVATION OF 100'-0" IS FOR
NOTE:
GENERAL NOTES:
1. ALL CMU WALLS ARE 8" UNLESS INDICATED OTHERWISE.
2. ALL STEEL STUDS ARE 4" UNLESS INDICATED OTHERWISE.
3. ALL MASONRY REINFORCEMENT IS INDICATED ON THE STRUCTURAL
DRAWINGS.
PERPENDICULAR WALL.
4. DOOR OPENINGS IN STUD WALLS SHALL BE LOCATED 4" AWAY FROM
5. ALL CHANGES IN FLOOR MATERIALS OCCUR AT THE CENTER LINE OF
DOORS IN THE CLOSED POSITION UNLESS INDICATED OTHERWISE.
6. DIMENSIONS ARE TO CENTER LINE OF COLUMNS, FACE OF STEEL STUDS
FACE OF CONCRETE & FACE OF MASONRY.
7. DOOR LOCATION DIMENSIONS ARE TO CENTER LINE OF DOOR IN
STEEL STUD WALL CONSTRUCTION, TO NOMINAL FACE OF MASONRY &
TO ACTUAL FACE OF OPENING IN CONCRETE WALL CONSTRUCTION.
10. REFER TO REFLECTED CEILING PLAN FOR FIRE RATED PARTITIONS.
9. REFER TO STRUCTURAL SHEETS FOR MASONRY REINFORCEMENT.
8. WALL TYPES INDICATED BY ARE LOACATED ON SHEET A-502OB AND A-503OB.X
1-1/2" STEEL HANDRAIL - TYP.
1'-0"
1'-0"
8'-0"
3"
WALL WITH BLOCKING - TYP.
REINFORCE STEEL STUD
BRACKETS SECURED TO WALL -
STEEL HANDRAIL SUPPORT
WALLS BEYOND
WALL WITH BLOCKING - TYP.
REINFORCE STEEL STUD
BRACKETS SECURED TO WALL -
STEEL HANDRAIL SUPPORT
1-1/2" STEEL HANDRAIL - TYP.
WALLS BEYOND
ELEV. 100'-0"
FINISH FLOOR
ELEV. 100'-0"
FINISH FLOOR @ LAB
6'-0" 1'-0"
6'-0" 1'-0"
3'-1" 2'-8 3/4"
A-101OB
F L
O O
R P
L A
N
M .D .M o r r is o n
M .D .M
B .R .G
A R
C H
S E
C T
IO
N a u t o u s e r n a m e a u t o d e s ig n t o s h o r t d e s ig n a u t o s c le t o s y t im e
SCALE: 1/4" = 1'-0"
0 4'4' 2'
COMPOSITE FLOOR PLAN
NORTH
PLAN
NORTH
TRUE
FOOTAGE 2860 S.F.
BUILDING TOTAL GROSS SQUARE
LAUNDRY ROOM107
ELECTRICAL ROOM106
OFFICE105
104 COMMUNICATION ROOM
BREAK AREA103
OPEN OFFICE102
READY ROOM101
LEGEND:
STORAGE CLOSET115
CORRIDOR114
JANITOR CLOSET112
LAB TEST ROOM111
MEN'S TOILET/LOCKER ROOM110
109 WOMEN'S TOILET/LOCKER ROOM
108 MECHANICAL ROOM
C
A-202OB
A-202OB
D
A-201OB
A
B
A-201OB
SCALE: 1/4" = 1'-0"
0 4'4' 2'
HANDRAIL ELEVATION AT LAB A
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
GYPSUM CEILING
CEILING TILE
1 X 4 LIGHT FIXTURE
(SEE ELECTRICAL)
LIGHT FIXTURE
(SEE ELECTRICAL)
RETURN AIR GRILL
OR EXHAUST GRILL
(SEE MECHANICAL)
(SEE MECHANCIAL)
TRANSFER AIR BOOT AND GRILLE
SUPPLY AIR DIFFUSER OR
2 X 4 LIGHT FIXTURE
(SEE ELECTRICAL)
RECESSED LIGHT FIXTURE
(SEE ELECTRICAL)
AND PLUMBING REQUIREMENTS.
ACCESSIBLE. SEE MECHANICAL DRAWINGS FOR ALL VENTILATION
ACOUSTICAL CEILING, AND THAT WOULD OTHERWISE NOT BE
LOCATED ABOVE THE CEILING, OTHER THAN IN SUSPENDED
VALVE, FLOW INDICATOR, DAMPER OR AIR SPLITTER THAT IS
1. ACCESS PANELS SHALL BE INSTALLED DIRECTLY BELOW EACH
NOTE:
2 X 2 ACOUSTICAL
LEGEND:
1-FIRE RATED WALL
PANELS
METAL SOFFIT
ROOM NAMES
109 WOMEN'S TOILET
108 MECHANICAL ROOM
107 LAUNDRY ROOM
106 ELEC. ROOM
105 OFFICE
104 COMM. ROOM
103 BREAK ROOM
102 OPEN OFFICE
101 READY ROOM
115 STORAGE
114 CORRIDOR
113 NOT USED
112 JANITOR CLOSET
111 LAB TEST ROOM
110 MEN'S TOILET
OVERHANG
BUILDING
EXPOSED
EXPOSED
EXPOSED
B
15'-0"
3'-0"
66'-8"
10'-0" 41'-8"
ACCESS PANEL
(SEE NOTE 1 AND PLUMBING DWGS.)
AP
AP
A P
OCCUPANCY SENSOR
(SEE ELECTRICAL)
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
ELEV. 109'-0"
CEILING
" G.W.B.8
BRACING
CEILING
ELEV. 108'-0"
BOTTOM OF SOFFIT
ELEV. 107'-6"
CEILING
ACOUSTICAL TILE
AT 16" O.C.
4" METAL STUDS
AT 16" O.C.
METAL STUDS
" G.W.B. CEILING8
CEILING
ELEV. 108'-0"
AND ASSEMBLY
DOOR, FRAME,
ACCESS PANEL
SYSTEM
SUSPENSION
METAL CEILING
GASKETTING - TYP.
A-131OB
R E
F L E
C T
E D C
E
IL
IN
G P
L A
N
M .D .M
O R
R
IS
O N
M .D .M
B .R .G
A R
C H t o u s e r n a m e a u t o d e s t o s h o r t d e s ig n a u t o s c t o s y t im e
SCALE: 1/4" = 1'-0"
0 4'4' 2'
REFLECTED CEILING PLAN
NORTH
TRUE
NORTH
PLAN
SOFFIT DETAIL A
SCALE: 1-1/2" = 1'-0"
0 1'1' 6"
ACCESS PANEL DETAIL B
SCALE: 1-1/2" = 1'-0"
0 1'1' 6"
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
66'-8"
41'-8"
10'-0"15'-0"
12'-0"42'-8"12'-0"
A
A-140OB A-511OB
B
A
A-140OB A-511OB
A
A-140OB A-511OB
A
A-140OB A-511OB
5'-0"
5'-0"
D.S.
SEE DETAIL D THIS SHT.
SPLASHBLOCK BELOW
TYPICAL
6" GUTTER
METAL ROOFING
STANDING SEAM
RIDGE CAP
BELOW
BUILDING LINE
R O
F
L
O P
E
F
O P
E
ROOF SLOPE
4 : 12
ROOF SLOPE
4 : 12
SEE DETAIL A THIS SHT.
FOR SIZE AND LOCATION
VENTS, SEE PLUMBING
SEE MECH
EXHAUST FAN,
SEE MECH
DUCT GOOSENECKS,
D.S.
D.S. D.S.
D .S
D .S
D .S
D .S
FLASHING
HIP CAP/
D.S.
2'-0"
TO DS
SLOPE
TO DS
SLOPE
G.E.J.
T O D
S
S L
O P
E
T O D
S
S L
O P
E
G.E.J.
TO DS
SLOPE
JOINT - G.E.J.
GUTTER EXPANSION
TO DS
SLOPE
T O D
S
S L
O P
E
T O D
S
S L
O P
EJOINT - G.E.J.
GUTTER EXPANSION
BASE - TYP.
SSMR SEAM CLAMPING
NON-PENETRATING
AIR TERMINAL WITH
FOR LOCATIONS
BASE - SEE EG101OB
SSMR SEAM CLAMPING
NON-PENETRATING
AIR TERMINAL WITH
B
SIM
C
A-140OB A-140OB
D
A-140OB A-511OB
EACH FASTENER HEAD
NEOPRENE GASKET UNDER
(R-19 MINIMUM)
INSULATION
FILL W/ BATT
- SEE STR.
RIDGE PLATE
CONT. METAL
- BEYOND
STEEL JOISTS
(SEE STRUCT. DWGS.)
STEEL RIDGE BEAM
STEEL ROOF DECK
MEMBRANE
LEAK BARRIER
VAPOR, AIR AND
WITH THE MANUFACTURER
PURLIN AS STANDARD
"Z" PURLIN - OR
INSULATION (R-15 MIN.)
3" OF RIGID ROOF
METAL ROOFING W/
STANDING SEAM
STD. W/ MFR.
W/ CONT. SEALANT AS
PANEL "Z" CLOSURE
BY ROOF MFR.
SEALANT AS RECOMMENDED
- SEE ELEC.
BRACKET- TYP.
NON SEAM PENETRATNG
AIR TERMINAL W/
AS STD. W/ MFR.
CONT. SEALANT AT LAPS
CONT. SUB-FLASHING W/
CAP AS STD. W/ MFR.
CONT. SSMR RIDGE
TO MATCH ROOF
BASE COLOR
PIPE THRU ROOF
FLEXIBLE EPDM
PIPE FLASHING
BOOT
CONTOURED TO
METAL BASE RING
ROOF PROFILE
STANDING SEAM
RIGID INSULATION
METAL ROOF W/
MAMBRANE
LEAK BARRIER
VAPOR, AIR, AND
STEEL DECK
DIRECTIONS
2'-0" IN ALL
EXTENDS
FLASHING
W /P
IP
E D
IA
V A
R
IE
S /2
M
IN
.BASE DIA. VARIES W/PIPE DIA.
4'-2"
/2
STANDARDS.
SHALL BE PER MANUFACTURER'S
COARSE AGGREGATE. REINFORCING
INCH TO NO. 4 NOMINAL SIZE 2
FOR BUILDING CONSTRUCTION USING
CONFORMING TO SECTION CONCRETE
CONSTRUCTED OF 4000 p.s.i. CONCRETE
PRECAST SPLASH BLOCKS SHALL BE
NOTE:
PIPE THRU ROOF
METAL FL BOOT
FLASHING BOOT OR
FLEXIBLE EPDM PIPE
FLANGED SLEEVE
LOW END AND INTEGRAL
DOWN OVER RIBS AT
METAL TRAY TURN
STANDING SEAM
RIGID INSULATION
METAL ROOF W/
MAMBRANE
LEAK BARRIER
VAPOR, AIR, AND
STEEL DECK
DIRECTIONS
2'-0" IN ALL
EXTENDS
FLASHING
W /P
IP
E D
IA
V A
R
IE
S /2
M
IN
.BASE DIA. VARIES W/PIPE DIA.
CLAMPING RING
STAINLESS STEEL
CLAMPING RING
COLLAR HOOD W/ S.S.
FABRICATED STORM
STAINLESS STEEL FIELD
A-140OB
O P
E R
A T
IO
N S B
U
IL
D
IN
G
R O
O F P
L A
N A
N D D
E T
IA
L S
X X t o u s e r n a m e a u t o d e s t o s h o r t d e s ig n a u t o s c t o s y t im e
ROOF DETAIL AT PLUMBING VENT - TYP. A
SCALE: 1-1/2" = 1'-0"
0 1'1' 6"
RIDGE/HIP CAP AND AIR TERMINAL DETAIL
SCALE: 1-1/2" = 1'-0"
0 1'1' 6"
ROOF PLAN
SPLASHBLOCK DETAIL D
A-101OB A-140OB
N.T.S.
NORTH
PLAN
NORTH
TRUE
A-101AF
B
ROOF DETAIL AT ROUND GOOSENECK DUCT C
SCALE: 1-1/2" = 1'-0"
0 1'1' 6"
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
METAL ROOFING
STANDING SEAM
METAL FASCIA
STANDING SEAM
ELEV. 113'-10"
TOP OF C.M.U.
ELEV. 107'-2"
TOP OF WINDOW
ELEV. 100'-0"
FINISH FLOOR
ELEV. 103'-2"
TOP OF ACCENT BAND
SPLIT FACE CMU
LAMINATED GLASS
ALUM. WINDOW W/
METAL ROOFING
STANDING SEAM
ALUM. DOOR
LAMINATED GLASS
ALUM. WINDOW W/
METAL FASCIA
STANDING SEAM
ELEV. 113'-10"
TOP OF C.M.U.
ELEV. 107'-2"
TOP OF WINDOW
ELEV. 103'-2"
T.O. ACCENT BAND
ELEV. 100'-0"
FINISH FLOOR
CONC. SPLASH BLOCK
ALUM. GUTTER
SPLIT FACE CMU
DOWNSPOUT
FACED CMU
1 ROW OF SMOOTH
FACED CMU
2 ROWS OF SMOOTH
SSMR BEYOND
GUTTER
FACED CMU
2 ROWS OF SMOOTH
DOWNSPOUT
ALUM. WINDOW
FACED CMU
1 ROWS OF SMOOTH
SEE ELEC.
LIGHT FIXTURE
TO RIDGE
HIP CAP - SIM
- SEE ELEC.
AIR TERMINAL
GUTTER
RIDGE CAP
TO RIDGE
HIP CAP - SIM
- SEE ELEC.
AIR TERMINAL
- SEE MECH.
GOOSENECK DUCT
STAINLESS STEEL
STACK- SEE MECH.
IN-LINE EXHAUST FAN
GUTTER
RIDGE CAP
SEE ELEC.
LIGHT FIXTURE
12 12
12 12
ELEV. 99'-6"
@ LAB TEST RM.
FINISH FLOOR
A-201OB
B U
IL
D
IN
G E
L E
V A
T
IO
N S
M .D .M
O R
R
IS
O N
M .D .M
B .R .G
A R t o u s e r n a m e a u t o d e s t o s h o r t d e s ig n a u t o s c t o s y t im e
ELEVATION A
A-101OB A-201OB
ELEVATION B
A-101OB A-201OB
SCALE: 1/4" = 1'-0"
0 4'4' 2'
SCALE: 1/4" = 1'-0"
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
RIDGE CAP
METAL ROOFING
STANDING SEAM
METAL FASCIA
STANDING SEAM
ELEV. 113'-10"
TOP OF C.M.U.
ELEV. 107'-2"
B.O. ACCENT BAND
ELEV. 100'-0"
FINISH FLOOR
ELEV. 103'-2"
TOP OF ACCENT BAND
- SEE MECH & DTL F/A702OB
HOODED WALL VENT
METAL ROOFING
STANDING SEAM
ALUM. DOOR
ELEV. 113'-10"
TOP OF C.M.U.
ELEV. 107'-2"
T.O. WINDOW
ELEV. 103'-2"
T.O. ACCENT BAND
ELEV. 100'-0"
FINISH FLOOR
SSMR BEYOND
GUTTER
SEE ELEC.
LIGHT FIXTURE
FACED CMU
2 ROWS OF SMOOTH
DOWNSPOUT
ALUM. DOOR
FACED CMU
1 ROW OF SMOOTH
SPLASHBLOCK
GUTTER
SPLIT FACE CMU
SEE ELEC.
LIGHT FIXTURE
SPLASHBLOCK
DOWNSPOUT
RIDGE CAP
METAL FASCIA
STANDING SEAM
SPLIT FACE CMU
ELEV. 109'-0" MIN
WALL VENT
B.O. HOODED
- SEE ELEC.
AIR TERMINAL
STACK- SEE MECH.
IN-LINE EXHAUST FAN- SEE MECH.
GOOSENECK DUCT
STAINLESS STEEL
- SEE MECH.
GOOSENECK DUCT
STAINLESS STEEL
- SEE ELEC.
AIR TERMINAL
RIDGE CAP
HIP CAP
DTL F/A702OB - SEE MECH.
FOR DRYERS - SIM. TO
HOODED WALL VENT
HIP CAP
A-202OB
B U
IL
D
IN
G E
L E
V A
T
IO
N S
X X t o u s e r n a m e a u t o d e s t o s h o r t d e s ig n a u t o s c t o s y t im e
ELEVATION C
A-101OB A-202OB
SCALE: 1/4" = 1'-0"
0 4'4' 2'
ELEVATION D
A-101OB A-202OB
SCALE: 1/4" = 1'-0"
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
(TP)
TOWEL PIN
WALL LINE
(TTD)
DISPENSER
TOILET TISSUE
(MH)
MOP HOLDER
ROD (SC/SCR)
SHOWER CURTAIN
SHOWER CURTAIN/
S U
R F
A C
E
R E
F L
T O
2'-0"
(SH)
SOAP HOLDER
(PTD/WR)
TOWEL DISPENSER
WITH WASTE RECEPTACLE
/2
METAL LOCKER
(ML)
M A
X
M
IN
7-9"
(MG)
MIRROR
GRAB BAR 2GRAB BAR 1
(GB1) (GB2)
MAX.
12"
MIN.
42"
HC
(TP)
TOWEL PIN
1'-0"
MIN.
12"
MIN.
24"
(SND)
DISPOSER
& TAMPON
SANITARY NAPKIN
(SD)
DISPENSER
SOAP
(EWC)
COOLER
ELECTRIC WATER
S P
O U
T H
E
IG
H T
M A
X
FOR EWC LOCATIONS
SEE DRAWING A-110
(EHD)
DRYER
ELECTRIC HAND
BACKSPLASH
COUNTERTOP W/
SOLID SURFACE
MECH. DWGS.)
LAVATORY (SEE
2" X 4" WD. FRAME
END PANEL BEYOND
3/4" PLYWOOD
2'-0"
8"
-6
LAMINATE
PLASTIC
6"
BEYOND
INT. DIVIDER
ST. STL. ANGLE @
STL. ANGLE
CONT. STAINLESS
3"x4"x1/4"
ELEV. = 102'-10"
ELEV. = 100'-0"
MIRROR (MG)
TAMPER SCREWS
STEEL NON-
REMOVABLE STAINLESS
SINK, ATTACHED W/
CENTERLINE OF EACH
ACCESS PANEL AT
PROVIDE 1' -0" WIDE
3/4" PLYWOOD (TYP.)
TP
SH
SH
SH
SH
SH
TP
TP
TP
TP
PTDWC
PTDWC
SC/SCR
SC/SCR
SC/SCR
SC/SCR
SC/SCR
SC/SCR
SC/SCR
SC/SCR
SC/SCRSC/SCR
TTD
TTD
3'-1"
7'-7" 6'-4"
3'-9"
4'-5"
7'-10"
8'-0"3'-6"
1'-7"
5'-8"
GB1
GB2
/8
GB1
GB2
12'-6"5'-6"
5'-6"
3'-6"
3'-1"
MR
AT 16" O.C.
6" METAL STUDS
ML ML
GB3
GB3
DRYING AREA.
ONE HANDICAP TOWEL PIN IN EACH HANDICAP SHOWER
60" ABOVE THE FINISH FLOOR FOR ALL OTHERS. PROVIDE
FINISH FLOOR FOR THE HANDICAP SHOWER AREAS AND
1. TOWEL PINS SHALL BE MOUNTED AT 40" ABOVE THE
NOTES:
GB-3 SHALL BE 24" LONG BY 18" LONG
GB-2 SHALL BE 36" LONG
GB-1 SHALL BE 42" LONG
BE AS FOLLOWS:
2. GRAB BAR LENGHTS SHALL
MORTAR BED. COORDINATE WITH STRUCTURAL FOR SLAB ELEVATION.
3. FLOOR TILE IN ROOMS 109 AND 110 SHALL BE INSTALLED IN A
5'-0"
5'-0"
MH
A-421OB A-902OB
5A
5B
5B
EACH HANDICAPPED SHOWER STALL.
4. PROVIDE ONE HANDICAPPED TOWEL PIN (TP) IN
HC
TP
HC
TP
WOMEN'S TOILET
MEN'S TOILET
JANITOR
5. WALL TYPES ARE LOCATED ON SHEETS A-502OB AND A-503OB
LAB TEST ROOM
MECHANICAL RM.
EHD
EHD
SD
SD
SND
TYP.
SEAT
SHOWER
FOLDING 9
9 9
A-421OB
E N
L A
R G
E T
O
IL
E T P
L A
N
A N
D F
IX
T U
R E
S E
L E
V A
T
IO
N S
M .D .M
M .D .M
B .R .G
A R
C H
IT
E C
T U
R t o u s e r n a m e a u t o d e s t o s h o r t d e s ig n a u t o s c t o s y t im e
ENLARGED TOILET PLAN
SCALE: 1/2" = 1'-0"
0 2'2' 1'
A
A-101OB A-421OB
SECTION
SCALE: 3/4" = 1'-0"
2' 1' 0 2'
NORTH
TRUE
NORTH
PLAN
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
ASSEMBLY
AIR BARRIER
CONTINUOUS
ASSEMBLY
AIR BARRIER
CONTINUOUS
BARRIER MEMBRANE
VAPOR, AND LEAK
CONTINUOUS AIR,
CONT. SPF
MEMBRANE
VAPOR RETARDER
CONTINUOUS AIR,
SEALANT ALL AROUND
TAPE AROUND ENTIRE OPENING
SELF ADHESIVE SHEATHING
SPRAY FOAM INSULATION
INSULATION BD. INTO CMU
FASTENERS THROUGH RIGID
WALL INSULATION
2" RIGID CAVITY
CMU VENEER ANCHOR
BARRIER MEMBRANE
JOINTS AND LAP AIR/MOISTURE
MEMBRANE - TAPE ALL
CONT. VAPOR RETARDER
BARRIER MEMBRANE
CONT. AIR/MOISTURE
MEMBRANE - LAP OPNG.
VAPOR RETARDER
CONT. AIR/MOISTURE
AIR/MOISTURE BARRIER 6" MIN.
OVER VAPOR RETARDER AND
TAPE AROUND ENTIRE OPNG
SELF-ADHESIVE FLASHING
CMU RETURN
ALL CORNERS & JOINTS - TYP.
ADHESIVE FLASHING TAPE -
REINFORCING MESH/SELF-
WAL INSULATION
2" RIGID CAVITY
INSULATION BOARD
MASONRY CAVITY WALL
LOW EXPANSION FOAM
FLUSH TO SURFACE
CURED FOAM SHAVED OFF
SHEATHING FLASHING TAPE
SELF ADHESIVE INSULATION/
BARRIER MEMBRANE
CONTINUOUS AIR/MOISTURE
TO EXTERIOR
PAN FLASHING - SLOPE TO DRAIN
RIGID INSULATION
OVERLAP EDGE OF PAN FLASHING
FENESTRATION FLASHING,
AIR/ MOISTURE BARRIER
RIGID INSULATION
(TOP, BOTTOM, AND SIDES)
EXTEND TO OUTSIDE OF OPENING
VAPOR RETARDER MEMBRANE
AIR/MOISTURE BARRIER/
A MINIMUM OF 6-INCHES
ON BOTH INTERIOR AND EXTERIOR
ALL EDGES OF OPENINGS AN RETURN
FENESTRATION FLASHING TO LAP
(TOP, BOTTOM, AND SIDES)
TO INSIDE OF OPENING
VAPOR RETARDER MEMBRANE
MEMBRANE TO EXTEND/LAP
AIR/MOISTURE BARRIER/
VAPOR RETARDER MEMBRANE
AIR/ MOISTURE BARRIER/
ON RIGID INSULATION BOARD
VAPOR RETARDER MEMBRANE
AIR/MOISTURE BARRIER/
EXTERIOR SHEATHING TAPE
WALL INSULATION BOARD
EXTERIOR MASONRY CAVITY
SELF-ADHESIVE FLASHING TAPE
THRU-WALL FLASHING
-IF APPLICABLE
BOTTOM OF MTL STUD TRACK
CONTINUOUS SILL SEALER AT
VAPOR RETARDER MEMBRANE
CONT. AIR/MOISTURE BARRIER/
TAPE OVER THE TOP OF BASE PLATE
ANCHOR BASE PLATE - FLASHING
SELF-ADHESIVE PATCH UNDER
LOW EXPANSION FOAM
8" CMU
8" CMU
SHOWN FOR CLARITY
4" CMU VENEER NOT
SHOWN FOR CLARITY
4" CMU VENEER NOT
8" CMU
VAPOR RETARDER MEMBRANE
CONT. AIR/MOISTURE BARRIER/
8" CMU
8" CMU
A-431OB
A
IR
B
A R
R
IE
R P
L A
N
M .D .M
M .D .M
B .R .G t o u s e r n a m e a u t o d e s
M
A
O B .D
G N a u t o s c t o s y t im e
AIR BARRIER SYSTEM ASSEMBLY PLAN
N.T.S.
TYPICAL AIR BARRIER SYSTEM ASSEMBLY DETAILS
TYPICAL AIR BARRIER SYSTEM ASSEMBLY SECTION
W A
L L S
E C
T
IO
N
A N
D D
E T
A
IL
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
METAL FASCIA PANEL
WALLBOARD
5/8" GYPSUM
RIGID ROOF INSULATION
2 LAYERS OF
ON STEEL TRUSS/JOISTS
METAL ROOF DECKING
STUDS AT 16" O.C.
2" STEEL FURRING
4" CMU
3'-0"
MEMBRANE
LEAK BARRIER
AIR, VAPOR, AND
ALUM. SOFFIT PANELS
THRU-WALL FLASHING
METAL FASCIA PANEL
INSULATION
RIGID ROOF
4" CMU
STEEL JOIST BEYOND
METAL SOFFIT PANELS
THRU-WALL FLASHING
FRAME
ALUM. WINDOW
LAMINATED GLASS
AT 16" O.C.
2" FURRING/STUDS
ACCENT COURSE
5/8" GWB
C
A-702OBA-501OB
A
A-702OBA-501OB
METAL ROOFING
STANDING SEAM
METAL ROOFING
STANDING SEAM
ELEV. 109'-10"
BOTTOM OF FASCIA
ELEV. 108'-6"
TOP OF ACCENT
ELEV. 103'-2"
TOP OF ACCENT
ELEV. 100'-0"
FINISH FLOOR
ELEV. 109'-10"
BOTTOM OF FASCIA
ELEV. 108'-6"
TOP OF ACCENT
ELEV. 103'-2"
TOP OF ACCENT
ELEV. 100'-0"
FINISH FLOOR
AT 16" O.C.
4" STEEL STUDS
SPLIT FACE CMU
A
ELEV. 113'-10"
TOP OF CMU
ELEV. 107'-2"
BO ACCENT
CONC. SPLASHBLOCK
SEE STRUCT. SHTS.
CONC. FOUNDATION
PERIMETER INSULATION (12")
R-7.5 RIGID UNDER-SLAB
B
A
A-511OBA-501OB
ON STEEL TRUSS/JOISTS
METAL ROOF DECKING
MEMBRANE
LEAK BARRIER
AIR, VAPOR, AND
SCORED ACCENT BLOCKS
SMOOTH FACE 1/2
SCORED ACCENT BLOCKS
SMOOTH FACE 1/2
INSULATION - (R-11)
CAVITY WALL
SCORED ACCENT BLOCKS
SMOOTH FACE 1/2
@ 16" O.C.
4" STEEL STUDS
CONT. SPF
CONT. SPF
B
A-501OB A-511OB
CONT. AIR/VAPOR BARRIER
GUTTER - TYP.
6" x 5" METAL
GUTTER - TYP.
6" x 5" METAL
A-501OB
B U
IL
D
IN
G W
A L L S
E C
T
IO
N S
A N
D D
E T
A
IL
S
M .D .M
O R
R
IS
O N
M .D .M
B .R .G
A R t o u s e r n a m e a u t o d e s t o s h o r t d e s ig n a u t o s c t o s y t im e
8" CMU
WALL SECTION 1
A-101OB A-501OB
2'
SCALE: 3/4" = 1'-0"
1' 0 2'
WALL SECTION 2
A-101OB A-501OB
2'
SCALE: 3/4" = 1'-0"
1' 0 2'
FIN. GRADE
W/ WEEPS
THRU WALL FLASHING
4" SPLIT FACE CMU
INSULATION
2" CAVITY
5/8" GWB
SCHEDULED
BASE AS
SEE STRUCT.
FLOOR SLAB
INSULATION
UNDER-SLAB
SEE STRUCT. SHTS.
CONC. FOUNDATION
DETAIL - TYP. A
SCALE: 1-1/2" = 1'-0"
0 1'1' 6"
INSULATION
2" CAVITY
CMU
4" SPLIT FACE
SEALANT
PANELS
ALUM SOFFIT
16" O.C.
STEEL STUDS AT
4" CMU
FLASHING
ALUM SOFFIT
DETAIL B
GROUT SOLID
MTL DRIP EDGE
COLLECTION MAT'L
MORTAR
0 3" 6" 9" 12"
SCALE: 3" = 1'-0"
"8
BARRIER
CONT. AIR
"4 32 "8
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
L O
P E
R A
T
IO
N S B
U
IL
D
IN
G
4" MTL. STUD PARTITION
STRUCTURE
UNDERSIDE OF
4'-0" O.C. (TYP.)
ALTERNATE DIRECTION AT
MTL. STUD BRACING
(SEE SCHEDULE)
WHERE OCCURS
FINISH CEILING
FRAMING AT 1'-4" O.C.
4" MTL. STUD
5/8" GWB EACH SIDE
FINISH SCHEDULE)
WALL BASE (SEE
FINISH SCHEDULE)
FINISH FLOOR (SEE
STRUCTURE
UNDERSIDE OF
(SEE SCHEDULE)
WHERE OCCURS
FINISH CEILING
O.C.
FRAMING AT 1'-4"
4" MTL. STUD
5/8" GWB EACH SIDE
FINISH SCHEDULE)
FINISH FLOOR (SEE
FINISH SCHEDULE)
WALL BASE (SEE
W-245
WAINSCOT TCA METHOD
PORCELAIN TILE
CONC. CURB
4" X STUD WIDTH
FINISH SCHEDULE)
FINISH FLOOR (SEE
5/8" GWB EACH SIDE
4'-0" O.C. (TYP.)
ALTERNATE DIRECTION AT
MTL. STUD BRACING
(SEE SCHEDULE)
WHERE OCCURS
FINISH CEILING
STRUCTURE
UNDERSIDE OF
4" MTL. STUD PARTITION
4'-0" O.C. (TYP.)
ALTERNATE DIRECTION AT
MTL. STUD BRACING
5/8" GWB
OCCURS (SEE SCHEDULE)
FINISH CEILING WHERE
STRUCTURE
UNDERSIDE OF
MTL. STUD PARTITION
MTL. STUD PARTITION
METHOD W-245
WAINSCOT, TCA
PORCELAIN TILE
4" MTL. STUD PARTITION
STRUCTURE
UNDERSIDE OF
OCCURS (SEE SCHEDULE)
FINISH CEILING WHERE
METHOD W-245
WAINSCOT, TCA
PORCELAIN TILE
WALLS
5/8" TYPE "X" GWB @ FR
MTL. STUD PARTITION
/2
FINISH SCHEDULE)
WALL BASE (SEE
FINISH SCHEDULE)
FINISH FLOOR (SEE
FIRE SAFING
STRUCTURE
UNDERSIDE OF
(SEE SCHEDULE)
WHERE OCCURS
FINISH CEILING
FINISH SCHEDULE)
FINISH FLOOR (SEE
FINISH SCHEDULE)
WALL BASE (SEE
OCCURS (SEE SCHEDULE)
FINISH CEILING WHERE 6
STRUCTURE
UNDERSIDE OF
TCA METHOD W-245
PORCELAIN TILE WALL
MTL. STUD PARTITION
IN WALL 5A & 5B
SOUND BATTS
IN WALL
SOUND BATTS
/2
/2
/2
4'-0" O.C. (TYP.)
ALTERNATE DIRECTION AT
MTL. STUD BRACING
FRAMING AT 1'-4" O.C.
20 GA 4" MTL. STUD
OCCURS (SEE SCHEDULE)
FINISH CEILING WHERE
STRUCTURE
UNDERSIDE OF
MTL. STUD PARTITION
TCA METHOD W-245
PORCELAIN TILE WALL
6" MTL. STUD PARTITION
5A
FIN. FLR.
ELEV. = 100'-0"
OR FIRE SAFING
COMPRESSIBLE FILLER
NON COMBUSTIBLE
FRAMING AT 1'-4" O.C.
20 GA 4" MTL. STUD
FRAMING AT 1'-4" O.C.
20 GA 4" MTL. STUD
FRAMING AT 1'-4" O.C.
20 GA 4" MTL. STUD
FRAMING AT 1'-4" O.C.
20 GA 4" MTL. STUD
5B
4" AND 6" MTL. STUD PARTITION
BATTS
SOUND ATTENAUTAION
NGC 2386
STC 42 MIN. - SIM. TO
16" O.C.
U425 EXCEPT STUDS
UL DES SIM TO NO.
RATING INDICATED:
WHERE 1-HOUR FIRE
SEALANT
ACOUSTICAL
MIN. 3//8" GAP W/
WALLS
5/8" TYPE "X" GWB @ FR
CONC.
WALLBOARD GLUED TO
5/8" GYPSUM
FRAMING AT 1'-4" O.C.
20 GA 6" MTL. STUD
CONT SEALANT
/2
NGC 2386
STC 42 MIN. - SIM. TO
O.C.
EXCEPT STUDS 16"
UL DES NO. U465
RATING INDICATED:
WHERE 1-HOUR FIRE
WALLS
5/8" TYPE "X" GWB @ FR
NGC 2386
STC 42 MIN. - SIM. TO
O.C.
EXCEPT STUDS 16"
UL DES NO. U425
RATING INDICATED:
WHERE 1-HOUR FIRE
SIDE - TYP.
CONT. SEALANT EA.
SIDE - TYP.
CONT. SEALANT EA.
NGC 2386
STC 42 MIN. - SIM. TO
TYP.
SEALANT EA. SIDE -
CONT. ACOUSTICAL
TYP.
SEALANT EA. SIDE -
CONT. ACOUSTICAL
DEFLECTION TRACK
FABRICATED
FACTORY OR FIELD
SEALANT
ACOUSTICAL
MIN. 3//8" GAP W/
DEFLECTION TRACK
FABRICATED
FACTORY OR FIELD
DEFLECTION TRACK
FABRICATED
FACTORY OR FIELD
OR FIRE SAFING
COMPRESSIBLE FILLER
NON COMBUSTIBLE
DEFLECTION TRACK
FABRICATED
FACTORY OR FIELD
OR FIRE SAFING
COMPRESSIBLE FILLER
NON COMBUSTIBLE
FINISH SCHEDULE)
WALL BASE (SEE
FINISH SCHEDULE)
FINISH FLOOR (SEE
SIDE - TYP.
CONT. SEALANT EA.
FINISH SCHEDULE)
WALL BASE (SEE
CONC. CURB
4" X STUD WIDTH
CONC. CURB
4" X STUD WIDTH
FINISH SCHEDULE)
WALL BASE (SEE
FINISH SCHEDULE)
FINISH FLOOR (SEE
FINISH SCHEDULE)
FINISH FLOOR (SEE
SIDE - TYP.
CONT. SEALANT EA.
FINISH SCHEDULE)
WALL BASE (SEE
CONC. CURB
4" X STUD WIDTH
MTL. STUD FURRING
STRUCTURE
UNDERSIDE OF
OCCURS (SEE SCHEDULE)
FINISH CEILING WHERE
TCA METHOD W-245
PORCELAIN TILE WALL
FINISH SCHEDULE)
WALL BASE (SEE
FINISH SCHEDULE)
FINISH FLOOR (SEE
TYP.
CONT. SEALANT -
CHANNELS AT 1'-4" O.C.
7/8" MTL. FURRING
A-502OB
W A
L L T
Y P
E S
M .D .M
O R
R
IS
O N
M .D .M
B .R .G t o u s e r n a m e a u t o d e s t o s h o r t d e s ig n a u t o s c t o s y t im e
File details come from the government source that posted it. Updated .