US Army Corps of Engineers
Omaha District
JUNE 2017
ADVERTISEMENT
MARSHALL ISLANDS
SOLICITATION NO. W9128A-17-B-0001
REPLACE FUEL STORAGE TANKS
PN DESC1704 (FY17)
DEFENSE FUEL SUPPLY POINT
KWAJALEIN ATOLL
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
K A
W
A -1
-C -0
X
A -1
-B -0
R E
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N D
Y
J U
N E
.1
X
S C
IN
E
G-002
M L
H
M L
H M
T a u t o s c le
S a u t o s h o r t d e s ig n a u t o s y t im e a u t o u s e r n a m e a u t o d e s ig n
INDEX
SHEET SEQUENCE NUMBER
w/ Level 2 Designator
DISCIPLINE DESIGNATOR
M - 2 0 1
2. DISCIPLINE DESIGNATORS:1. SHEET IDENTIFICATION NUMBERS:
Designator)
RELEASE 3.0 for Level 2
(see A/E/C CADD STANDARD
INDEX LEGEND:
SHEET TYPE DESIGNATOR
3. SHEET TYPE DESIGNATORS:
3D REPRESENTATIONS
USER DEFINED
USER DEFINED
SCHEDULES & DIAGRAMS
DETAILS
LARGE-SCALE VIEWS
SECTIONS
ELEVATIONS
PLANS
GENERAL
FA
EI
EG
EP
EL
MH
M-
A-
AD
X-
S-
EX
ES
ED
MS
MD
CU
CE
CG
CP
CS
CD
VF
GC
GI
G-
FIRE DETECTION AND ALARM
ELECTRICAL INSTRUMENTATION
ELECTRICAL GROUNDING
ELECTRICAL INTERIOR POWER
ELECTRICAL INTERIOR LIGHTING
MECHANICAL HVAC
MECHANICAL
ARCHITECTURAL
ARCHITECTURAL DEMOLITION
TANKS
STRUCTURAL
ELECTRICAL CATHODIC PROTECTION
ELECTRICAL SITE
ELECTRICAL DEMOLITION
MECHANICAL SITE
MECHANICAL DEMOLITION
CIVIL UTILITY
CIVIL EROSION CONTROL
CIVIL GRADING
CIVIL PAVING
CIVIL SITE
CIVIL DEMOLITION
FIELD SURVEY
GENERAL CIVIL
GENERAL INFORMATION
GENERAL
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
IN
E X
C O
N T
G-003
H
M L
H M t o s c le
S a u t o s h o r t d e s ig n a u t o s y t im e a u t o u s e r n a m e a u t o d e s
INDEX (CONT.)
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
G-004
B
B R
E V
IA
T
IO
N
H
M L
H M
T S
R
I6
G
-0
ABBREVIATIONS
ANGLE
ACOUSTICAL WALL TREATMENT
AMERICAN WIRE GAUGE
AVERAGE
AUTOMATIC
AUTOMATIC TANK GAUGING
ACOUSTICAL TILE CEILING
ASSISTANT
ASPHALT
ASBESTOS
AMERICAN REFRIGERATION INSTITUTE
ARCHITECTURAL OR ARCHITECT
AMERICAN PETROLEUM INSTITUTE
ACCESS PANEL
INSTITUTE
AMERICAN NATIONAL STANDARDS
AMPERE
ALTERNATE
ACTIVE LEAF
ALUMINUM
CONSTRUCTION
AMERICAN INSTITUTE of STEEL
AMPS INTERRUPTING CAPACITY (SYM RMS)
AREA INLET
AIR HANDLING UNIT
AGGREGATE
AUTOMATED FUEL HANDLING EQUIPMENT
AQUEOUS FILM FORMING FOAM
ABOVE FINISH FLOOR
ARC FAULT CIRCUIT INTERRUPTOR
ADMINISTRATION/ADMINISTRATIVE
AREA DRAIN
ACCESS DOOR
ACOUSTIC
ALUMINUM CABLE - STEEL REINFORCED
AMERICAN CONCRETE INSTITUTE
AIR CONDITIONING
ALTERNATING CURRENT
ANCHOR BOLT
AUTOMATIC AIR VENT
AWT
AWG
AVG
AUTO
ATG
ATC
ASSIST.
ASPH
ASB
A.R.I.
ARCH
API
AP
ANSI
AMP
ALT
A.L.
ALUM
AISC
AIC
A.I.
AHU
AGGR
AFHE
AFFF
AFF
AFCI
ADMIN
AD
AD
ACST
ACSR
ACI
A/C
AC
AB
AAV
BUILT-UP ROOFING
BTU PER HOUR
BRITISH THERMAL UNIT
BENT
BOTTOM SEDIMENT AND WATER
BASKET STRAINER
BRACKET
BRICK
BEARING
BRIDGING
BRACING
BULLETPROOF (BULLET-RESISTANT)
BOTTOM
BOTTOM OF
BENCH MARK
BEAM
BLOCKING
BLOCK
BUILDING
BUILDING LINE
BITUMINOUS
BRICK EXPANSION JOINT
BOTH ENDS
BOUNDARY
BOARD
BOOKCASE
BARREL
BATT INSULATION
BUR
BTUH
BTU
BT
BSAW
BS
BRKT
BRK
BRG
BRDG
BRCG
BPRF
BOT
B.O.
BM
BM
BLKG
BLK
BLDG
BL
BITUM
BEJ
BE
BDRY
BD
BC
BBL
BATT INSUL
B
CONSTRUCTION
CONNECTION
CONFERENCE
CONCRETE
COMMUNICATION
COMBUSTION
COMBINATION
COMMON
COLUMN
CORPS OF ENGINEERS
CARBON DIOXIDE
CARBON MONOXIDE
CLEANOUT
COUNTER
CONDUIT (FOR RACEWAY-ELEC. SHTS)
CONCRETE MASONRY UNIT
CORRUGATED METAL PIPE
CLEAR WIRE GLASS
CLEARANCE
CLOSED
CLOSET
CAULKING
CEILING
CLASS
CENTER LINE
CIRCUIT BREAKER
CIRCUIT
CHECKED
CONSTRUCTION JOINT
CONTROL JOINT
CIRCULAR
CAST IRON
CURB INLET
CHIMNEY
CERAMIC FLOOR TILE
CUBIC FEET PER SECOND
CODE OF FEDERAL REGULATIONS
CUBIC FEET PER MINUTE
CEMENT
COVER ELEVATION
CIRCUIT BREAKER
CATCH BASIN
CENTER TO CENTER
CAPACITY
CONSTR
CONN
CONF
CONC
COMM
COMB
COMB
COM
COL
COE
CO
CO
CO
CNTR
CND
CMU
CMP
CLWG
CLR
CLOS
CLO
CLKG
CLG
CL
CL
CKT BRKR
CKT
CKD
CJ
CJ
CIRC
CI
CI
CHIM
CFT
CFS
CFR
CFM
CEM
CE
CB
CB
C TO C
CAP
C
CYLINDER
CERAMIC WALL TILE
COLD WATER
CHECK VALVE
CEILING VENT
CUBIC YARDS
CABINET UNIT HEATER
COPPER
CONDENSING UNIT
CENTER
CARPET TILE
CURRENT TRANSFORMER
CERAMIC TILE
CASEMENT
CAST STONE TILE
COUNTER SUNK
CARBON STEEL
COURSE
CARRIAGE
CORROSIVE RESISTANT STEEL
CARPET
CYCLES PER SECOND (HERTZ)
COMPRESSIBLE
CATHODIC PROTECTION
COVERED
CORRIDOR
CORNER
CONTINUOUS
CONSTRUCTION JOINT
CYL
CWT
CW
CV
CV
CU YD
CUH
CU
CU
CTR
CTL
CT
CT
CSMT
CST
CSK
CS
CRSE
CRG
CRES
CPT
C.P.S. ~
CPRS
CP
COV
CORR
COR
CONT
CONSTR JT.
C (cont.)
DX
DWLS
DWG
DS
DR
DR
DMPF
DN
D & M
DIV
DISTR
DISC
DISSEM
DIP
DIM
DIAG
DIA or Ø
DHW
DH
DH
DF
DET
DEPT
DEPR
DEG
DCW
DCL
DCJT
DCJ
DC
DBL
DBB
DB
DAT
DA
d
D
DIRECT EXPANSION
DOWELS
DRAWING
DOWNSPOUT
DRAIN
DOOR
DAMPPROOFING
DOWN
DRESSED & MATCHED
DIVISION
DISTRIBUTION
DISCONNECT
DISSEMANATION
DUCTILE IRON PIPE
DIMENSION
DIAGONAL
DIAMETER
DOMESTIC HOT WATER
DUCT HEATER
DOUBLE HUNG
DRINKING FOUNTAIN
DETAIL
DEPARTMENT
DEPRESSION
DEGREE
DOMESTIC COLD WATER
DOOR CLOSER
DUMMY CONTROL JOINT
DOWELED CONTROL JOINT
DIRECT CURRENT
DOUBLE
DOUBLE BLOCK AND BLEED PLUG VALVE
DRY BULB
DATUM
DOUBLE ACTING
PENNY (as in nail - 10d)
EXTERIOR
EXPLOSION PROOF
EXPANSION
EXPOSED
EXISTING
EXHAUST
EXIT DEVICE
EXCAVATE
ET CETERA
ENTERING WATER TEMPERATURE
ELECTRIC WATER COOLER
ESTIMATE
EACH SIDE
EQUIPMENT
EQUAL
EMERGENCY POWER DOWN SWITCH
ENTRANCE
ENCLOSURE
ESTIMATED MAXIMUM DEMAND
ELEVATOR
ELECTRIC or ELECTRICAL
ELEVATION - GRADE OR BUILDING
EXPANSION JOINT
EXTERIOR INSULATION & FINISH SYSTEM
EMERGENCY FUEL SHUT-OFF
EMERGENCY EYEWASH & SHOWER
ECCENTRIC
ENTERING AIR TEMPERATURE
EXHAUST AIR
EACH
EAST
EXT
EXPL
EXP
EXP
EXIST
EXH
EXD
EXC
EWT
EWC
ETC
EST
ES
EQUIP
EQ
EPDS
ENTR
ENCL
EMD
ELEV
ELEC
EL
EJ
EIFS
EFSO
EES
ECC
EAT
EA
EA
E
E
FWC
FW
FUR
FTG
FT
FSCV
FSC
F/S
FS
FS
FRP
FR
FPM
FP
FP
FOB
FML
FLUOR
FLG
FLEX
FLASH
FLR
FIXT
FIN
FIG
FHC
FH
F (cont.)
GLAZED WALL TILE
GYPSUM WALL BOARD
GYPSUM
GUTTER
GRAZED STRUCTURAL UNIT
GALVANIZED RIGID STEEL CONDUIT
GRADE
GALLONS PER MINUTE
GROUND
GOVERNMENT
GLASS
GALVANIZED IRON
GROUND FAULT INTERRUPTOR
GOVERNMENT FURNISHED EQUIPMENT
GOVERNMENT INSTALLED
GOVERNMENT FURNISHED EQUIPMENT
CONTRACTOR INSTALLED
GOVERNMENT FURNISHED EQUIPMENT
GROUND FAULT CIRCUIT INTERRUPTOR
GENERAL
MAT
GEOSYNTHETIC CEMETITIOUS COMPOSITE
GALVANIZED
GALLON
GAGE or GAUGE
GUTTER
NATURAL GAS
GWT
GWB
GYP
GUT
GSU
GRS
GR
GPM
GND or GRND
GOVT
GL
GI
G.F.I. or GFI
GFE
GFE/GI
GFE/CI
GFCI
GEN
GCCM
GALV
GAL
GA
G
G
G
HERTZ
HYDRAULIC
HOT WATER HEATER
HOT WATER
HEADWALL
HEATER
HEATING
HOLLOW STRUCTURAL SECTION
PLASTERHEIGHT
HIGH - STRENGTH GYPSUM
HIGH STRENGTH
HAND SWITCH
HOUR
HIGH-POINT VENT
HIGH POINT
HIGH PRESSURE
HORSEPOWER
HIGH MOLECULAR WEIGHT POLYETHYLENE
HOLLOW METAL
HIGH LIQUID LEVEL SHUT-OFF VALVE
HIGH LEVEL SWITCH
HIGH LEVEL ALARM
HIGH-HIGH LEVEL SWITCH
HIGH-HIGH LEVEL ALARM
HAND HOLE
HARDWARE
HANDRAIL
HEADER
HIGH DENSITY POLYETHYLENE
HARDBOARD
HEAD
HALON CONTAINMENT DAMPER
HANDICAP
HOSE BIBB
Hz
HYDR
HWH
HW
HDWL
HTR
HTG
HSS
HT
HSGYP
HS
HS
HR
HPV
H.PT.
HP
HP
HMWPE
HM
HLV
HLS
HLA
HHLS
HHLA
HH
HDW
HNDRL
HDR
HDPE
HDBD
HD
HCD
HC
HB
JOINT
JOIST
JUNCTION
JUNCTION BOX
JANITOR CLOSET
JT
JST
JCT
J-BOX
JC
KILOWATT HOUR
KILOWATT
KILOVOLT AMPERE REACTIVE
KILOVOLT AMPERE
KILOVOLT
KICK PLATE
KEY LOCK
KITCHEN
KILOPOUND (1000 LBS)
KILO CIRCULAR MIL
KEY
THOUSAND
kWh kW kVAR kVA kV
KPL
KL
KIT
KIP
kcmil or KCM
K
K
J
K
L
LWT
LVP
LT WT
LTG
LT
L.R.
LR
LPT
LPS
LPD
LONG
LNTL
LM
LLS
LLLS
LLLA
LLA
LIS
LIN
LG
LDG
LD
LBS
LBR
LB
LAV
LAU
LAT
LAB
LEAVING WATER TEMPERATURE
LOW VOLTAGE POWER
LIGHT WEIGHT
LIGHTING
LIGHT
LONG RADIUS
LIVING ROOM
LOW POINT
LIGHT PROOF SHADE
LOW-POINT DRAIN
LONGITUDINAL
LINTEL
LUMEN
LOW LEVEL SWITCH
LOW-LOW LEVEL SWITCH
LOW-LOW LEVEL ALARM
LOW LEVEL ALARM
LAWN IRRIGATION SYSTEM
LINEAR
LENGTH
LOADING
LOAD
POUNDS
LUMBER
ELBOW
LAVATORY
LAUNDRY
LEAVING AIR TEMPERATURE
LABORATORY
M
MTL
MTD
MT
MSTC
MSL
MSB
MOV
MOT
MO
MLDG
ML
ML
MIN
MH
MGT
MGT
MG
MFR
MFG
MER
MECH
MCJ
MCC
MC
MC
M & B
MAX
MAV
MAT
MAS
MAINT
MACH
MA
M
METAL
MOUNTED
METAL THRESHOLD
MASTIC
MEAN SEA LEVEL
MAIN SWITCH BOARD
MOTOR OPERATED VALVE
MOTOR
MASONRY OPENING
MOLDING (MOULDING)
MONOLITHIC
METAL LATH
MINIMUM
MANHOLE
MANAGEMENT
MATTE - GLAZED TILE
MOTOR GENERATOR
MANUFACTURER
MANUFACTURING
MECHANICAL EQUIPMENT ROOM
MECHANICAL
MASONRY CONTROL JOINT
MOTOR CONTROL CENTER
MOLDED CASE
MEDICINE CABINET
MATCHED & BEADED
MAXIMUM
MANUAL AIR VENT
MATERIAL
MASONRY
MAINTENANCE
MACHINE
MIXED AIR
THOUSAND
N
NOT TO SCALE
NOT REQUIRED
NATIONAL PIPE THREAD
NORMALLY OPEN
NUMBER
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
ASSOCIATION
NATIONAL ELECTRICAL MANUFACTURERS
NATIONAL ELECTRICAL CODE
NON COMMISSIONED OFFICER
NORMALLY CLOSED
NORTH
N.T.S.
N.R.
NPT
NO
NO.
NIC
NFPA
NEMA
NEC
NCO
NC
N
O
OSHA
OS & Y
O.R.
OPS
OPP
OPNG
OH
OGL
OFF
OD
OD
OCEW
O.C.
OWGL
OBSC
OA
P
PW
PVMT
PVC
PTN
PTD
PT
PT
P.T.
PST
PSI
PSF
P.S.
PRV
PRV
PROJ
PROC
PREFIN
PREFAB
PR
PPM
PORC
POL
POL
PNL
PLYWD
PLG
PLC
PLBG
PLAT
PLAS
PLAM
PL or P
PIV
PI
PI
PH
P.E.
PERF
PDI
PC
P.C.
P.C.C.
PBS
PB
PART
PA
P
PASS WINDOW
PAVEMENT
POLYVINYL CHLORIDE (PLASTIC)
PARTITION
PAINTED
POTENTIAL (VOLTAGE) TRANSFORMER
POINT
POINT OF TANGENCY
PRODUCT SAVER TANK
POUNDS per SQUARE INCH
POUNDS per SQUARE FOOT
PRESSED STEEL
PRESSURE REDUCING VALVE
PRESSURE REGULATING VALVE
PROJECT
PROCESSING
PREFINISH
PREFABRICATE
PAIR
PARTS PER MILLION
PORCELAIN
PETROLEUM, OIL, LUBRICANT
POLISHED
PANEL
PLYWOOD
PILING
PROGRAMMABLE LOGICAL CONTROLLER
PLUMBING
PLATFORM
PLASTER
PLASTIC LAMINATE
PLATE
POST INDICATOR VALVE
PRESSURE INDICATOR
POINT OF INTERSECTION
PHASE
POLYETHYLENE
PERFORATED
PRESSURE DIFFERENTIAL INDICATOR
PIECE
POINT OF CURVE
PORTLAND CEMENT CONCRETE
PUSH BUTTON STATION
PULL BOX
PARTICLE
PUBLIC ADDRESS
POLE
L
Q
QUARTER ROUND
QUANTITY
QUARTER
QUARRY TILE
QUART
1/4 RD
QTY
QTR
QT
QT
R
RECLAIMED WATER
RAISED PATTERN RUBBER TILE
REVOLUTIONS PER MINUTE
RND
ROOM
RELATIVE HUMIDITY
ROUGH
RAISED FLOOR SYSTEM
ROOFING
REVISION
RESILIENT
REQUIRED
REPRODUCE
REMOVABLE
REINFORCE
REGISTER
REFRIGERATOR
REFERENCE
RECTIFIER
RECREATION
RECEPTACLE
RIDGE
ROOF DRAIN
RECEIVER
REINFORCED CONCRETE PIPE
REMOTE CONTROL
RUBBER
RESILIENT BASE
RETURN AIR REGISTER
RETURN AIR GRILLE
RETURN AIR
RELIEF AIR
RANGE
RADIUS
RISER
RW
RPRT
RPM
RND
RM
RH
RGH
RFS
RFG
REV
RESIL
REQD
REPRO
REM
REINF
REG
REFR
REF
RECT
RECR
RECPT
RDGE
RD
RCVR
RCP
RC
RBR
RB
RAR
RAG
RA
RA
R
R
R
S
SYMM
SWBD
SW
SVF
SV
SUSP
SUB FL
STWY
STRUCT
STR
ST PR
STOR
STN
STL
STD
STC
STA
SST or SS
SSMR
SRV
SQ or
SPKR
SPH
SPF
SPEC
SPCL
SOV
SJI
SIM
SHTHG
SHT
SHLDR
SFU
S.F.
SEQ
SECT
SDI
SD
SD
SCUT
SCT
SCR
SCIF
SCHED
SCH
S.B.
SB
SA
S
SYMMETRICAL
SWITCHBOARD
SWITCH
SOLENOID VALVE
SHEET VINYL FLOORING
SUSPEND
SUBFLOOR
STAIRWAY
STRUCTURAL
STRINGER
STATIC PRESSURE
STORAGE
STONE
STEEL
STANDARD
SOUND TRANSMISSION CLASS
STATION
STAINLESS STEEL
STANDING SEAM METAL ROOFING
SAFETY RELIEF VALVE
SQUARE
SPEAKER
SPACE HEATER
SOUNDPROOF
SPECIFICATION
SPECIAL
SHUT OFF VALVE
STEEL JOIST INSTITUTE
SIMILAR
SHEATHING
SHEET
SHOULDER
STRUCTURAL FACING UNIT
SQUARE FOOT (FEET)
SEQUENCE
SECTION
STEEL DECK INSTITUTE
SUBDRAIN
SMOKE DAMPER
SCUTTLE
STRUCTURAL CLAY TILE
SCREW
INFORMATION FACILITY
SENSITIVE COMPARTMENTED
SCHEDULE
SCHEDULE
SECURITY BARS
SPLASH BLOCK
SUPPLY AIR
SOUTH
T
TYPICAL
TELEVISION
THERMOSTAT
TRANSVERSE
THERMAL RELIEF VALVE
TOPOGRAPHY
TOILET
TOP OF
TACK BOARD
NYLON-COATED
THERMOPLASTIC HIGH WATER-RESISTANT
THRESHOLD
THREAD
THICKNESS
TOGGLE
TERMINAL
TERRAZZO
TEMPERATURE
TELEPHONE
TECHNICAL
TOP ELEVATION
TILE COUNCIL of AMERICA
TOP OF CURB
TANGENT
TREAD
TYP
TV
TSTAT
TRANS
TRV
TOPO
TOIL
TO
TK BD
THWN
THRES
THRD
THK
TGL
TERM
TER
TEMP
TEL
TECH
TE
TCA
TC
TAN
T
UV
UTIL
UR
UPS
UON
UNFIN
UNEX
UNC
UL
UH
UG
UFGS
UFC
UC
UNIT VENTILATOR
UTILITY
URINAL
UNINTERRUPTIBLE POWER SYSTEM
UNLESS OTHERWISE NOTED
UNFINISH
UNEXCAVATED
UNIFIED NATIONAL COARSE
UNDERWRITERS LABORATORIES
UNIT HEATER
UNDERGROUND
UNIFIED FACILITIES GUIDE SPECIFICATIONS
UNIFIED FACILITIES CRITERIA
UNIT COOLER
U
V
VINYL-WALL COVERING
VENT THRU ROOF
VOLTAGE TRANSFORMER
VINYL-TILE
VENT STACK
VOLTAGE REGULATOR
VAPOR RETARDER
VERTICAL POINT OF TANGENCY
VERTICAL POINT OF INTERSECTION
VERTICAL POINT OF CURVATURE
VOLUME
VARIABLE FREQUENCY DRIVE
VESTIBULE
VERTICAL
VENTILATOR
VENTILATION
VOLUME DAMPER
VAULT DOOR
VINYL COMPOSTION TILE
VITRIFIED CLAY PIPE
VOLT
VWC
VTR
VT
VT
VS
VR
VR
V.P.T.
V.P.I.
V.P.C.
VOL
VFD
VEST
VERT
VENT
VENT
VD
VD
VCT
VCP
V
W
WOVEN WIRE MESH
WELDED WIRE FABRIC
WEIGHT
WAINSCOT
WASTE STACK
WARDROBE
WATER PROOFING
WEATHER PROOF
WELD NECK FLANGE
WORK SHOP
WROUGHT IRON
WHITE
WATTHOUR METER
WALL HYDRANT
WIRED GLASS
WIDE FLANGE
WINDOW
WOOD DOOR
WOOD BLOCKING
WASTE DRAIN
WOOD
WATER CLOSET
WET BULB
WITHOUT
WITH
WIRE
WEST
WWM
WWF
WT
WSCT
WS
WRB
WP
WP
WNF
WKSH
WI
WHT
WHM
WH
WGL
WF
WDW
WD. DR.
WD. BLK.
W.D.
WD
WC
WB
W/O
W/
W
W
X
DOUBLE EXTRA STRONG
TRANSFORMER
XXS
XFMR
Y
YD
YD
YARD DRAIN
YARD
IP
INV
INT
INSUL
IN
IESNA
I.E.
ID
IC
IC
I or EF
IRON PIPE
INVERT or INVERTRE
INTERIOR
INSULATION
INCHES
SOCIETY of NORTH AMERICA
ILLUMINATION ENGINEERING
INVERT ELEVATION
INSIDE DIAMETER
INSULATED CASE
INTERCOM
IRON
I
F
F.E.S
FEC
FEB
FE
FDN
FD
FD
FCJ
FCG
FCC
FC
FB
FA
F
FLARED END SECTION
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER BRACKET
FIRE EXTINGUISHER
FOUNDATION
FIRE DAMPER
FLOOR DRAIN
FLOOR CONSTRUCTION JOINT
FACING
FEDERAL COMMUNICATIONS COMMISSION
FOOTCANDLE
FLAT BAR
FRESH AIR
FAHRENHEIT
FABRIC WALLCOVERING
FIRE WATER
FURRING
FOOTING
FEET
FILTER SEPARATOR CONTROL VALVE
FUEL SAMPLE CONNECTOR
FILTER/SEPARATOR
FLOW SWITCH
FULL SIZE
FIBERGGLASS REINFORCED PIPE
FRAME
FEET PER MINUTE
FIREPROOF
FIRE PROTECTION
FLAT ON BOTTOM
FLEXIBLE MEMBRANE LINER
FLUORESCENT
FLOORING
FLEXIBLE
FLASHING
FLOOR
FIXTURE
FINISH
FIGURE
FIRE HOSE CABINET
FIRE HYDRANT
H
ADMINISTRATION
OCCUPATIONAL SAFETY AND HEALTH
OUTSIDE SCREW & YOKE
OBSERVATION RISER
OPERATIONS
OPPOSITE
OPENING
OVERHEAD
OBSCURE GLASS
OFFICE
OVERFLOW DRAIN
OUTSIDE DIAMETER
ON CENTER EACH WAY
ON CENTER
OBSCURE WIRE GLASS
OBSURE
OUTSIDE AIR
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
G E
N
G-005
H
M L
H M t o s c a le
R W
S a u t o s h o r t d e s ig n a u t o s y t im e a u t o u s e r n a m e a u t o d e s
STANDARD NORTH ARROWS
GENERAL NOTES:
AND HATCHED THUSLY.
3. EXISTING FACILITIES TO BE REMOVED ARE INDICATED BY USE OF THESE SYMBOLS
ON THIS SHEET.
SET OF DRAWINGS TO INDICATE SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN
2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY APPEAR IN THIS
THE CONDITIONS ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO
DUCTWORK
20 x 12 RG
20 x 12 SG
700 CFM
20 x 12 GR
20 x 12 SR
700 CFM
700 CFM
20 O/
700 CFM
700 CFM
MECHANICAL LEGEND
HPS
HEATING
LPC
FW
PC
FEED WATER
PUMPED CONDENSATE
LPS
MPS
MPC
HTWS
HPC
LOW PRESSURE CONDENSATE
MEDIUM PRESSURE CONDENSATE
HIGH PRESSURE CONDENSATE
LOW PRESSURE STEAM
MEDIUM PRESSURE STEAM
HIGH PRESSURE STEAM
HIGH TEMPERATURE WATER SUPPLY
DOOR GRILLE
12 x 12
700 CFM
DG
12 x 6
20 x 12
R
BBD
FOG
BOILER BLOW-DOWN
FUEL OIL GAGE LINE
FOS
FOF
FOR
GASG
FOV
FUEL OIL FILL
F & T TRAP
FUEL OIL RETURN
FUEL OIL SUPPLY
THERMODYNAMIC TRAP
FUEL OIL TANK VENT
HTWR
HWS
HWR
GHWS
GHWR
F FLOAT TRAP
THERMOSTATIC TRAP
BUCKET TRAP
A
VAC
F
FC
F
VACUUM
FIRE LINE
COMPRESSED AIR
FOAM CONCENTRATE
HIGH TEMPERATURE WATER RETURN
HOT WATER HEATING RETURN
HOT WATER HEATING SUPPLY
UNDERSLAB FIRE LINE
MISCELLANEOUS PIPING
FOR AFFF SYSTEMS
GLYCOL HOT WATER HEATING RETURN
GLYCOL HOT WATER HEATING SUPPLY
ROADS
NEW
WALKS
CULVERT
77.2
EXISTING
77.2
SD
W
FW
S
FW
WD
OR OR
FM
SD
W
S
FW
FM
FW
WD
PIV
MW-2
MT
MW-1
MT
DH-2 DH-2
PIV
BUILDINGS
CURB & GUTTER
CIVIL LEGEND
RAILROAD
CONTOURS
STORM DRAIN
DIRECTION OF DRAINAGE
SPOT GRADE ELEVATIONS
SUBDRAIN
FIRE WATER LINE
FORCE MAIN
SANITARY SEWER
WATER LINE
SUBDRAIN OUTLET LINE
OBSERVATION RISER
UTILITY LINE
WASTE DRAIN
SUBDRAIN FLUSHING &
AREA INLET
FIRE HYDRANT
POST INDICATOR VALVE
MONITORING WELL
CONTROL POINT
DRILL HOLE
CURB INLET
DEPENDING ON TYPE OF
OR SERVICE STOP & BOX
PROPERTY LINE MONUMENT
FIRE PROTECTION WATER LINE
MANHOLE SELF EXPLANATORY
GATE VALVE & VALVE BOX
FIRE DAMPER:
MODSEC.
VD
OR
FD
AD
SD
AD
AD
AS INDICATED
WOOD
XX
NEW
X
EARTH
CONCRETE
XX
X
EXISTING
AS INDICATED
GRAVEL
BRICK
METAL
PLYWOOD
WOOD (FINISH)
WOOD (ROUGH)
AS INDICATED
CRUSHED ROCK
PLASTER
GLASS (ELEVATION)
BLANKET INSULATION
RIGID INSULATION
GYPSUM WALLBOARD
WOOD STUD PARTITION
CONCRETE MASONRY UNITS (PLAN)
CONCRETE MASONRY UNITS (SECTION)
GLASS (LARGE SCALE SECTION)
METAL STUD PARTITION
ARCHITECTURAL LEGEND
FENCES
WOVEN WIRE
BARBED WIRE
CHAIN LINK SECURITY
SUPPLY GRILLE (SG)
FLOW DIRECTION
FLOW DIRECTION
DIRECTION OF FLOW
SPLITTER DAMPER
ACCESS PANEL (AP)
ACCESS DOOR (AD)
FLEXIBLE DUCT
TURNING VANES
SMOKE DAMPER
(TYPE AS SPECIFIED) INDICATE
SUPPLY OUTLET, CEILING, RECTANGULAR
(TYPE AS SPECIFIED) INDICATE
SUPPLY OUTLET, CEILING ROUND
CEILING (INDICATE TYPE)
EXHAUST OR RETURN AIR INLET
+ INTEGRAL VOL. CONTROL)
SUPPLY REGISTER (SR) (A GRILLE
GRILLE (NOTE AT FLR. OR CLG.)
RETURN (RG) OR EXHAUST (EG)
VENTILATOR-SUPPLY (SRV)
POWER OR GRAVITY ROOF
UNIT HEATER (VERTICAL)
POINT OF CHANGE IN DUCT CONSTRUCTION
VENTILATOR-EXHAUST (ERV)
POWER OR GRAVITY ROOF
UNIT HEATER (HORIZONTAL)
PARALLEL BLADE DAMPERS
FOR NET FREE AREA
2ND FIGURE, SIDE NOT SHOWN)
DUCT (1ST FIGURE, SIDE SHOWN
FLAT ON TOP OR F.O.B. FLAT
TRANSITIONS: GIVE SIZES. NOTE F.O.T.
IN DIRECTION OF AIR FLOW
INCLINED RISE (R) OR DROP (D) ARROW
DUCT SECTION (EXHAUST OR RETURN)
DUCT SECTION (SUPPLY)
ACOUSTICAL LINING DUCT DIMENSIONS
(BY STATIC PRESSURE CLASS)
OPPOSED BLADE DAMPERS
SHOW HORIZ. POS.
SHOW VERTICAL POS.
AUTOMATIC DAMPERS MOTOR OPERATED
VOLUME DAMPER MANUAL OPERATION
& RETURN (NO SPLITTER)
STANDARD BRANCH FOR SUPPLY
FLEXIBLE CONNECTION
ON BOTTOM IF APPLICABLE
GLOBE VALVE
W/TAMPER SWITCH
NEEDLE VALVE
STRAINER
HOSE GATE VALVE
GATE VALVE
M
S
SOLENOID VALVE
RELIEF VALVE
PA
FLOAT VALVE
BALL VALVE
BUTTERFLY VALVE
ANCHOR
WAFER CHECK VALVE
O, S, & Y GATE VALVE
PRESSURE REDUCING VALVE
MOTOR OPERATED VALVE
AUTOMATIC BALANCING VALVE AS INDICATED
CALIBRATED BRONZE BALANCING VALVE OR
PLUG VALVE OR BALANCING COCK
TEMPERATURE REGULATING VALVE
CAP
ELBOW UP
TEE UP
TEE DOWN
ELBOW DOWN
UNION
BLIND FLANGE
FLANGE
EXPANSION JOINT, BELLOWS
EXPANSION JOINT, SLIDING
PIPE INCREASER OR DECREASER
VALVES & FITTINGS
VENT
HB
WALL HYDRANT
HOSE BIBB
DOMESTIC HOT WATER
DOMESTIC COLD WATER
CLEAN OUT
FLOOR DRAIN
CO
D
CO
ST
ST
RL
RD
RS
CWS
CWR
CR
CHWS
CHWR
GCWS
THERMOSTATT
GCWR
C
FOR ADDITIONAL LEGEND
WALL CLEAN OUT
STORM DRAIN BELOW FLOOR
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
REFRIGERANT STRAINER
CHILLED WATER RETURN
CHILLED WATER SUPPLY
REFRIGERANT SUCTION
REFRIGERANT DISCHARGE (HOT GAS)
REFRIGERANT LIQUID
CHILLED-HOT WATER RETURN
GLYCOL CHILLED WATER RETURN
GLYCOL CHILLED WATER SUPPLY
CHILLED-HOT WATER SUPPLY
THERMOSTATIC EXPANSION VALVE
STORM DRAIN ABOVE FLOOR
SEE TEMPERATURE CONTROL DRAWINGS
S
N
OA
E
H
P
PB
HUMIDITY SENSOR
PRESSURE SENSOR
EMCS SENSOR
MANUAL OVER-RIDE SWITCH
NIGHT THERMOSTAT
TEMPERATURE SENSOR
PLUMBING
REFRIGERATION
TEMPERATURE CONTROLS
COND CONDENSATE DRAIN LINE
OR SENSOR (AS INDICATED)
OUTDOOR AIR THERMOSTAT
FCO FLOOR CLEAN OUT
A-7A-5 A-6 A-7 A-8
A
C D
A
A-
B
A
A-
SECTION NUMBER
SHEET NUMBER OF DWG.
OF ELEV. ON PLAN
DIRECTION OF SIGHT
ELEV. IS SHOWN
OF ELEV. ON PLAN
DIRECTION OF SIGHT
WHERE ELEV. IS SHOWN *
NOTE: LOCATION OF DWG. WHERE
WHERE SECTION IS SHOWN *
SHEET NUMBER OF DRAWING
WHERE SECTION IS CUT *
SHEET NUMBER OF DRAWING
DRAWING WHERE SECTION IS SHOWN
SECTION IS CUT WILL BE LISTED ONLY ON
ANY ADDITIONAL DRAWINGS WHERE
CUT AND DETAILED ON SAME DRAWING.
* SHEET NUMBERS OMITTED IF SECTION IS
SECTION IDENTIFICATION
ELEVATION IDENTIFICATION
ARCHITECTURAL SYMBOLS
101 ROOM NUMBER
DOOR NUMBERS
COLUMN LINES NUMBER-LETTER (OPPOSITE DIR.)
MATCH LINE
WINDOW TYPES
CENTER LINE
X DIRECTION OF SIGHT OF PHOTOGRAPH
WALL AND PARTITION TYPES
A
A
A 1
101101
SAN SANITARY SEWER
RW RECLAIMED WATER
V
WH
DCW
DHW
POLE, NO., LENGTH, AND CLASS AS INDICATED
CLASS 7 SOIL) "MT" INDICATES TWIN EYE ANCHOR ROD
(ANCHOR STRENGTH IS BASED ON HOLDING POWER IN
DOWN GUY AND ANCHOR. STRENGTH IN LBS. INDICATED
OVERHEAD COMMUNICATIONS LINE
EXTERIOR ELECTRICAL LEGEND
EXIST NEW
APPROX. HORIZ. AIMING
ARROWS INDICATE NO. OF LUMINAIRES AND
POLE MOUNTED FLOODLIGHTING INSTALLATION.
CONDUCTOR AND LINE VOLTAGE AS INDICATED.
SERVICE DROP NO., SIZE AND TYPE OF
OVERHEAD POWERLINE-SECONDARY OR
VOLTAGE AS INDICATED
NO., SIZE, AND TYPE OF CONDUCTORS AND LINE
OVERHEAD POWERLINE-PRIMARY DISTRIBUTION.
SIZE AND TYPE OF WIRE AS INDICATED.
LIGHTING CIRCUIT RESPECTIVELY. NO.,
SERIES STREET LIGHT AND AIRFIELD
NUMERAL INDICATES IES TYPE DISTRIBUTION
INSTALLATION, WATTS AS INDICATED, ROMAN
POLE MOUNTED ROADWAY OR AREA LIGHTING
OR PER CROSS SECTION DETAIL
LINE). NO., SIZE AND VOLTAGE OF CABLE AS INDICATED
ELECTRICAL POWER LINE, "C" A COMMUNICATIONS TYPE
MIN. IF NOT IDENTIFIED). LETTER "P" INDICATES
SPECS). NUMERAL INDICATES QUANTITY OF DUCTS (4"
UNDERGROUND DUCT LINE, CONCRETE ENCASED (SEE
ANSI (C84.1) VOLTAGE CONFIGURATION AS INDICATED.
CONCRETE PAD MOUNTED TRANSFORMER INSTALLATION
NUMBER, SIZE, AND TYPE OF CABLE AS INDICATED
VOLTAGE), "C" A COMMUNICATIONS TYPE LINE.
CABLES ARE USED), "S" SECONDARY POWER (LOW
PRIMARY POWER (#8 MIN. IF SINGLE-CONDUCTOR
DIRECT BURIED LINE. THE LETTER "P" DESIGNATES
AND RACEWAY AS DESCRIBED ( * ) OR DETAILED
CONFIGURATIONS. NO. AND SIZE OF CONDUCTORS
UNDERGROUND DISTRIBUTION-MISC.
NO., AND TYPE AS INDICATED
PULLBOX, HANDHOLE OR MANHOLE.
VAULT (POWER OR CONTROLS)
UNDERGROUND ELECTRICAL EQUIPMENT
CABINET OR EQUIPMENT ASSEMBLY
ELECTRICAL EQUIPMENT IN PAD MOUNTED
NUMERAL IF PRESENT DESIGNATES KVA RATING
CONFIGURATION AS INDICATED, SINGLE
FENCED APPLICATIONS. ANSI VOLTAGE
INDIVIDUAL TRANSFORMER FOR OVERHEAD OR
PHOTOELECTRIC CONTROL RELAY
AERIAL AUTOMATIC RECLOSER.
AERIAL AUTO SECTIONALIZER
(COUNTERPOISE) (BARE COPPER) SIZE AS INDICATED
GROUNDING SYSTEM. ELECTRODE AND CONDUCTOR
LIMITS OF CONDUIT CASING OR SLEEVE
CAPPED CONDUIT
DRAWOUT FUSE ASSEMBLY
RESPECTIVELY, SIZE AS INDICATED
FUSE-POWER AND CONTROL APPLICATIONS
BUS NUMBER FOR ANALYSIS AND REFERENCE ONLY
VOLTAGE RATING AND SIZE AS INDICATED
FUSED CUTOUT OR FUSED SWITCH ASSEMBLY.
FRAME SIZE WITH ADJUSTABLE TRIP SETTINGS.
MOLDED CASE CIRCUIT BREAKER OF A GIVEN
THREE POLE UNLESS DESIGNATED '1P' OR '2P'.
MOLDED CASE CIRCUIT BREAKER, FIXED TRIP.
MOLDED CASE CB TYPE). SIZE AS INDICATED.
INDICATES INSULATED CASE, "MC" INDICATES
("LVP" INDICATES LOW VOLTAGE POWER CB, "IC"
DRAWOUT TYPE CIRCUIT BREAKER ASSEMBLY
RATING AND CLASS AS INDICATED
SURGE ARRESTOR - VOLTAGE
- NUMBER DENOTES KVAR RATING
POWER FACTOR CORRECTION CAPACITOR
STEEL (#6 MIN. CONDUCTOR IF NOT SHOWN)
TYPE ELECTRODE, TO NEAREST STRUCTURAL
GROUND CONNECTION - TO STANDARD ROD
BETWEEN BREAKERS, RELAY/CONTACTOR, ETC.)
BETWEEN 2 OR MORE DEVICES (KEY INTERLOCK
CONTROL INTERFACE OR OPERATING RELATIONSHIP
IDENTIFIED). AMPACITY AS INDICATED
ASSEMBLIES (HIGH OR MEDIUM VOLTAGE). (CU BUS IF NOT
FEEDER TYPE BUS DUCT (FB) OR METAL-ENCLOSED BUS
LOADBREAK AND NON-LOADBREAK STYLES RESPECTIVELY
(ELBOW TERMINATOR AND BUSHING COMBINATION)-
SEPARABLE CONNECTOR IN PRIMARY DISTRIBUTION LINE
KILOWATT-HOUR METER (WH IS WATT-HOUR METER)
PARENTHESIS INDICATES QUANTITY OF CT'S
OF METERING/ACCESSORY CIRCUIT. NUMERAL IN
TRANSFORMATION RATIO IDENTIFIES NOMINAL CURRENT
CURRENT TRANSFORMER (CT). SECOND NUMERAL OF
INDICATED
AND NON-DRAWOUT. QUANTITY AND VOLTAGE RATING AS
VOLTAGE (POTENTIAL) TRANSFORMER (VT/PT), DRAWOUT
INDICATED.
VOLTAGE, CONNECTIONS, COOLING CLASS AND TYPE AS
POWER & DISTRIBUTION TRANSFORMER, RATED kVA, USED BY A TRANSFORMER SYMBOL.
TRANSFORMER DELTA CONNECTION DESIGNATION WHEN
IT IS AN UNGROUNDED OR FLOATING WYE CONNECTION.
RESPECTIVELY. IF THE GROUND SYMBOL IS MISSING, THEN
DIRECT GROUNDED AND RESISTOR GROUNDED
DESIGNATION WHEN USED BY A TRANSFORMER SYMBOL,
TRANSFORMER GROUNDED-WYE CONNECTION
AMMETER AND VOLTMETER WITH PHASE SELECTOR SWITCH
INTERLOCKING CONTROL AS INDICATED
WITH TRIP SETTING AT DESIGNATED TIME DELAY
GROUND FAULT INTERRUPTING EQUIPMENT (SEE SPECS)
FUNCTION PER ANSI/IEEE C37.2
ELECTROMECHANICAL); NUMERAL IDENTIFIES TYPE OR
SENSOR, DEVICE OR APPARATUS (ELECTRICAL OR
EXISTING AND NEW, RESPECTIVELY
CORRESPONDING SWITCH
THEN 2' X 2' IN SIZE - LETTER IDENTIFIES
INCANDESCENT OR H.I.D. LUMINAIRE LESS
FIXTURE C )
WALL FIXTURE - MOUNTING HEIGHT INDICATED (TO
OMITTED IN CONTINUOUS ROW CONFIGURATIONS)
SIZE (THE OUTLET SYMBOL WILL NORMALLY BE
FLUORESCENT OR HID LUMINAIRE 2' x 2' OR LARGER IN
OF EGRESS
CEILING EXIT LIGHT. ARROWS IDENTIFY DIRECTION
(TO C ), ARROWS IDENTIFY DIRECTION OF EGRESS
WALL EXIT LIGHT - MOUNTING HEIGHT INDICATED
VOLTAGE RATINGS AS INDICATED
LIGHTING CONTACTOR - NO. OF POLES, CURRENT AND
RATINGS AND PHYSICAL SIZE AS INDICATED
BATTERY INVERTER SET (OR FORWARD TRANSFER UPS),
EMERGENCY POWER SYSTEM FOR EGRESS LIGHTING -
LUMINAIRE HEADS AS INDICATED
BATTERY OPERATED EMERGENCY LIGHT SET, NO. OF
WITH THE 'E' ANNOTATION
2-LAMP FIXTURE WILL BE SHOWN SHADED OR UNSHADED
SUPPLIED FROM EMERGENCY POWER. A 1-LAMP OR
INDICATES 2 LAMPS OF A 3 OR 4 LAMP FIXTURE ARE
THE SHADED PORTION OF THE FLUORESCENT SYMBOL
FIXTURE, RESP. SUPPLIED FROM AN EMERGENCY CIRCUIT.
FEEDER, DEVICE OR FIXTURE, AND FLUORESCENT TYPE
CEILING AND WALL MOUNT TYPES INDICATED.
JUNCTION BOX, 4" SQUARE UNLESS NOTED OTHERWISE.
DIMMING CONTROL FOR LIGHTING
OVERLOADS (MOTOR RATED SWITCH)
MANUAL STARTER WITH THERMAL
DOUBLE POLE SINGLE THROW SWITCH
SINGLE POLE SWITCH
THREE WAY SWITCH
FOUR WAY SWITCH
SINGLE POLE SWITCH WITH PILOT LIGHT
TIMER OPERATED SWITCH
KEY OPERATED SWITCH
MOMENTARY CONTACT SWITCH
8.
OUTLETS, NEMA 5-XX SERIES. DEFAULT SIZE IS 15A. SEE NOTE
CLOCKOUTLET, FO= FAN OUTLET, IG= ISOLATED GROUND TYPE
DUPLEX & SIMPLEX "SW" INDICATES SPLIT WIRED, CO=
2P,3W GROUNDING TYPE RECEPTACLE - 125V, CONVENTIONAL
FIXTURES
SWITCHED
IDENTIFY
WHERE USED,
C, ETC.
LETTERS A, B,
4'-0" UP
APPLICATIONS) UNLESS NOTED OTHERWISE
PLANS) IN SURFACE MOUNTED RACEWAY. WALL MOUNTED AT
RECEPTACLES SPACED AT INTERVAL INDICATED (SEE FLOOR
RECEPTACLE STRIP ASSEMBLY - DUPLEX NEMA 5-15
OTHERWISE.
BOTTOM OF THE OUTLET BOX, UNLESS INDICATED
BE MOUNTED 15 - INCHES A.F.F. AS MEASURED TO THE
8. ALL RECEPTACLE AND COMMUNICATION OUTLETS SHALL
ABBREVIATIONS SHEET FOR DEFINITIONS.
INDICATE SPECIAL CONSTRUCTION IS REQUIRED. SEE
7. LETTERS SUCH AS "WP", "EP" ADJACENT TO ANY SYMBOL
CONDUCTORS UNLESS INDICATED OTHERWISE.
6. SIZES OF WIRE AND CABLE ARE BASED ON COPPER
FIXTURE PER FIXTURE SCHEDULE.
ADJACENT TO SYMBOL INDICATES FIXTURE TYPE FOR EACH
(B) CAPITAL LETTER OR FIXTURE DESIGNATION INSIDE OR
WHEN ADJACENT TO THE FIXTURE SYMBOL.
NAME OR NUMBER DESIGNATION OR FOR SINGLE FIXTURE
FOR ENTIRE ROOM OR AREA WHEN ADJACENT TO THE ROOM
(A) INDICATES FIXTURE TYPE, PER FIXTURE SCHEDULE,
BOTH OF THE FOLLOWING METHODS:
5. ELECTRIC LIGHT FIXTURES ARE IDENTIFIED BY EITHER OR
(FILLED-IN) SYMBOL.
OPEN SYMBOL; NEW ITEMS WITH A THICK LINE OR CLOSED
4. EXISTING ITEMS ARE DESIGNATED BY A THIN LINE OR AN
3. NOT USED.
CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
NOT COVERED BY THIS SHEET OR TO INDICATE SPECIFIC
THIS SET OF DRAWINGS TO ESTABLISH SYMBOLS FOR ITEMS
2. SUPPLEMENTAL ELECTRICAL LEGENDS MAY APPEAR IN
PREFERRED FORM IS SHOWN FIRST.
1. WHERE MORE THAN ONE SYMBOL FORMAT IS SHOWN, THE
K
234B1
NOTED
ELECTRIC WATER COOLER (DRINKING WATER DISPENSER) SIZE AS
RECESSED (FLUSH MOUNTED) TYPE, SEE SPECS
MOUNTED TYPE (ABOVE FLOOR SERVICE FITTING), 'R' DENOTES
INDIVIDUAL FLOOR OUTLET ASSEMBLY.'SM' DENOTES SURFACE
TO EXTEND ABOVE SUSPENDED CEILING. SEE NOTE 8.
RELOCATIBLE SERVICE POST ASSEMBLY - LENGTH AS REQUIRED
TELEPHONE, P= PUBLIC TELEPHONE, SEE NOTE 8.
THE DEVICE INDICATE IT IS FLOOR MOUNTED. HL=HOTLINE
WITHOUT LEG(S) REQUIRES DUPLEX JACKS. A SQUARE AROUND
CONFIGURATIONS (8 PIN JACKS). SEE SPECS. SYMBOL SYMBOL
TELEPHONE OUTLET, SINGLE AND DUPLEX JACK
DIMENSIONS AS INDICATED (W X D)
CABLE TRAY FOR COMMUNICATIONS AND DATA PROCESSING,
TELEPHONE TERMINAL CABINET, SIZE AS INDICATED
TELEPHONE TERMINAL BOARD (PLYWOOD BACKBOARD);
(NO INSERTS).
NOMINAL WIDTH; UFD IDENTIFIES A SECTION OF FEEDER DUCT
COMMUNICATIONS DUCT W/BUSHED FITTING; FIGURES IDENTIFY
DUCT WITH DUPLEX RECEPTACLES (NEMA 5-15), 'C' DENOTES
SOLID DENOTES A DEVICE INSTALLATION; 'P' INDICATES A POWER
(SEE SPECS.). OPEN CIRCLE DENOTES BLANK INSERT LOCATION,
MULTIOUTLET CONFIGURATION IN UNDERFLOOR DUCT SYSTEM
- PART WINDING TYPE.
REDUCED VOLTAGE TYPE, 'AT' - AUTO TRANSFORMER TYPE, 'PW"
FULL VOLTAGE TYPE (DEFAULT IF NOT INDICATED), 'RV' -
INDICATES: 'R' - REVERSING TYPE, '2S' - TWO SPEED TYPE, 'FV'-
NUMERAL DESIGNATES NEMA SIZE; LOWER LETTER, IF USED,
MOTOR CONTROLLER - MAGNETIC OR AS INDICATED, UPPER
MOTOR - USE AND SIZE AS INDICATED
COMBINATION STARTER W/EXTERNALLY OPERATED DISCONNECT
240V, 30A MIN)
DISCONNECT SWITCH, SIZE AND TYPE AS INDICATED (OR 3P,
EMERGENCY POWER OFF.
PUSHBUTTON CONTROL STATION - 1, 2, OR 3 BUTTONS "EPO" =
'MAN-OFF-AUTO' (OR 'H.O.A.)
LEGEND PLATE DESIGNATIONS WILL BE 'ON-OFF' AND
3 POSITION AS INDICATED. IF NOT SPECIFIED ELSEWHERE,
SELECTOR SWITCH (SEPARATE FROM STARTER)- 2 POSITION OR
THERMOSTAT - SEE MECH. SPECS, 5'-0" UP
SCHEDULE FOR SIZES, RATINGS, AND LOADS
(MIN) VERTICAL SECTIONS INDICATED. SEE DIAGRAM AND/OR
MOTOR CONTROL CENTER, FREE STANDING W/NO. OF 20" WIDE
SCHEDULE. OPEN SYMBOL INDICATES EXISTING
AND SURFACE MOUNTED TYPES, SEE CORRESPONDING PANEL
LIGHTING AND APPLIANCE TYPE PANELBOARD - FLUSH MOUNTED
DISTRIBUTION TYPE PANEL
DIMENSIONS, CLEARANCES, AND ELECTRICAL RATINGS
SPELLED OUT), SEE FLOOR PLANS AND DIAGRAMS FOR
MAIN SWITCH BOARD OR MAIN SWITCH GEAR (ABBREVIATED OR
DEVICE.
(FIGURES INDICATE RATING OF RECEPT AND OVERCURRENT
RECEPT. SYMBOL IDENTIFIES A BOX WITH RECEPTACLE ATTACHED
CIRCLE A PLUG IN BOX WITH BREAKER OR SWITCH (SEE SPECS),
REPRESENTS A POSITION WITH BLANK COVER ONLY, SOLID
INTERVALS, CURRENT RATING AS INDICATED. OPEN CIRCLE
BUS DUCT ASSEMBLY WITH PLUG-IN POWER BOX CAPABILITY AT 2'
EQUIPMENT GROUND RESPECTIVELY (AS APPLICABLE).
CONDUCTOR, NEUTRAL, EQUIPMENT GROUND, AND ISOLATED
DOT AND DOUBLE DOT HASH MARKS REPRESENT PHASE
BRANCH CIRCUIT AND FEEDER WIRING. LONG, SHORT, SINGLE
THE CIRCUIT IS TWO-WIRE (MIN #12 IN 1/2"C).
SEGMENTS. A CIRCUIT WITHOUT ANY DESIGNATION INDICATES
UNDERSTOOD TO APPLY TO ALL UNMARKED INTERVENING
SEGMENTS, AND END-OF-LINE DEVICES, REQUIRED QUANTITY IS
IF HASH MARKS ARE OMITTED BETWEEN HOME-RUNS, TRANSITION
ARROWS AND LETTER/NUMERALS IDENTIFY HOME-RUN CIRCUITS.
CONDUIT ONLY - NO CONDUCTORS, PULL WIRE IF OVER 50'
LIGHT LINE - EXISTING, OR BY OTHER TRADES
COATED R.S. CONDUIT UNLESS INDICATED OTHERWISE
COMM OR POWER FEEDER INSTALLED UNDER FLOOR SLAB IN
HEAVY LINE - NEW ELECTRICAL WORK
MATCH LINES, ETC.)
(TO LIGHTING SHEET FROM POWER OR COMM DWG., ACROSS
FUTURE WORK OR ELECTRICAL ITEM REPEATED FOR CLARITY
(NEW LOCATION)
EXISTING EQUIPMENT; EXISTING EQUIPMENT AS RELOCATED
GENERATOR OR GENERATOR CONNECTION.
XRX
LP-2,4,6
/2
A
MSGMSB
LP2
MCC-2
B
NOTE 5
G
CO
UF
MC
K
T
P
TO
20A
X"
INTERIOR ELECTRICAL LEGEND
FIRE ALARM CONTROL PANEL, (SEE SPECS)
SPECS
W/OR W/O GRAPHIC REPRESENTATION, SEE
FIRE ALARM ANNUNCIATION PROVISIONS,
ANTENNA FOR FM RADIO TYPE), SEE SPECS
FIRE ALARM SIGNAL TRANSMITTING (WITH
MANUAL FIRE ALARM STATION - 4'-0" A.F.F.
LOCATION IS NOT OTHERWISE INDICATED.
INSTALLED IN THE SUPPLY DUCT IF THE
DUCTS, A SINGLE DETECTOR WOULD BE
LOCATIONS ARE IN SUPPLY AND RETURN
DUCT DETECTORS ARE SHOWN IN PAIRS,
DUCT TYPE SMOKE DETECTOR. WHERE
PHOTOELECTRIC TYPE. 'D' STIPULATES A
PRESENT, STIPULATES IONIZATION OR
SMOKE DETECTOR. THE LETTER 'I' OR 'P', IF
SWITCH, SEE MECH. SPECS
VALVES, WATER FLOW INDICATOR AND FLOW
Y) VALVE, TAMPER SWITCH, ALARM CHECK
FIRE ALARM CONTACTS AT SOLENOID (OS &
24-INCH LIGHTNING AIR TERMINAL.
60-INCH LIGHTNING AIR TERMINAL.
LIGHTNING PROTECTION MAIN CONDUCTOR
NOTES:
ELECTRICAL POWER DIAGRAM LEGEND
#2
40'-4 40'-4
6M
12 MT
6M
II
WP2#6
OHSOHS
4-#6 ACSR
3#1
OHPOHP
13.8KV
3#1
OHC OHC
1-#6 CWC
AFL
1#6
SL
USE
4#8, TYPE
DBP DBP
DBS
DBCDBC
DBS
4P
4P/2C
2C 2C
+3 SPARE
1-#3 600V
3-#3,15 KV
4P
UG
UG
PB#4 HH#2 MH#4
A
EV EV
EPEP
PE PE
R
SSSS
R
#4
2" C
G
LVP
400A
3P
20 A
1600AF
1200AT
9KV
50A
SS
1600A
FBFB
KWH
1200:5
(3)
(3)
AS A VS V
400 AT
0.3 s#2
GFI
50N 51N
27B3
A
+7'
EPS
E E
OR
E
J J
D
S S S S
S
S
S
S
S
3/4HP
SM
SM
R
CT
12" X 4"
TTB-2
36X24X6
TTC#4
7"
3"P
C
UF
UF
UFD
UFD
EF-3 2HP
M
#3
2S
SS2PHOAS
T
PB
400A
FCP FCP
FAA FAA
FSTFST
F
F
I D P
WFITSSVOSY
STATIC GROUND ROD
A.F.F.
NOTIFICATION, HORN, BELL, OR CHIME - 6'-8"
AND VISIBLE - FLASHING LIGHT WITH A MASS
F.A. WARNING DEVICE, COMBINED AUDIBLE
FS
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
OF ENGINEERS
US ARMY CORPS
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
OMAHA DISTRICT
O M
A H
A
N E
B R
A S
A -1
-C -0
A -1
-B -0
P L
A C
E F
U E
L S
T O
R A
G E T
A N
K S
K W
A J
A L E
IN
A
T O
L L
M A
R S
H A
L L I S
L A
N
N E
.1
X
S C
E
C R
IC
A L L
E G
E N
G-006
H
M L
H M t o s c a le
R W
S a u t o s h o r t d e s ig n a u t o s y t im e a u t o u s e r n a m e a u t o d e s
File details come from the government source that posted it. Updated .