Amendment 0001 - Telecommunications Infrastructure.pdf

PDF 4 MB Posted

Attached to
ACC Replacement 13 Area Replacement Initial Outfitting Project Federal contract opportunity
Solicitation number
W9127S21Q6000
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

This solicitation requests quotes for the ACC Replacement 13 Area Replacement Initial Outfitting Project. The scope of work includes providing all labor, materials, equipment, transportation, and supervision to complete the initial outfitting of the new medical clinic in accordance with the technical packages. Quotes are due by February 11, 2021 at 12:00pm Central Time. The requirement is set aside for Service-Disabled Veteran-Owned Small Businesses. The contracting agency is the Department of the Army Corps of Engineers Engineering District Little Rock.

View the file

Other files for this federal contract opportunity

Other files attached to ACC Replacement 13 Area Replacement Initial Outfitting Project, newest first.
File Type Posted
Revised PRICE SCHEDULE W9127S21Q6000.xlsx XLSX spreadsheet
Amednment 0001 - Approved VTC list.pdf PDF
Amendment 0001 - ProjNet Inquiries.pdf PDF
W9127S21Q6000 Amendment 0001.pdf PDF
Amendment 0001 - Additional Cutsheets.pdf PDF
P021 AREA 13 MEDICAL CLINIC - Final CID Submittal Redacted.pdf PDF
DMLSS CRLL 13 Area.xlsx XLSX spreadsheet
6.4.1 PN14021 AREA 13 MEDICAL CLINIC-dwgs2of2.pdf PDF
P021 AREA 13 MEDICAL CLINIC - Final SID Submittal Redacted.pdf PDF
X5700 Full Cut Sheet.pdf PDF
Attachment (014) - Program for Design 13 Area Marine Centered Medical Ho....pdf PDF
W9127S21Q6000 Combined Synopsis Solicitation.docx DOCX document
6.4.1 PN14021 AREA 13 MEDICAL CLINIC-dwgs1of2.pdf PDF
X5700 Basis of Design Drawings.pdf PDF
13 AreaLtr 1092-09 Construction Baseline Schedule_20200511.pdf PDF
Staging and Area Map.pdf PDF
6.8.1 PN14021 AREA 13 MEDICAL CLINIC - Final Medical Equipment.pdf PDF
6.8.1 PN14021 AREA 13 MEDICAL CLINIC-spc1of3.pdf PDF
6.8.1 PN14021 AREA 13 MEDICAL CLINIC-spc3of3.pdf PDF
6.8.1 PN14021 AREA 13 MEDICAL CLINIC-spc2of3.pdf PDF
6.7 PRICE SCHEDULE_PN14021_CP_13Area_ACC DEC2020.xlsx XLSX spreadsheet
Attachment 1 - SOW for FY21 ACC Replacement.pdf PDF
PN 14021 CP ACC Replacement_13 Area_IOT Requirement Doc-FY21_14JAN2021_V6.docx DOCX document
7.2 WEEKLY RISK REPORT_PN14021_CP_13Area_ACC_21SEP20.xlsx XLSX spreadsheet
6.6.1 PN14021 AREA 13 MEDICAL CLINIC - PRC.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VOICE/DATA OUTLET, WALL MOUNTED, FOR DESK MOUNTED INSTRUMENTS,

PROVIDE 1 VOICE CABLE AND 2 DATA CABLE,TYPICAL ALL DEVICES UON.

TELECOMMUNICATIONS INFRASTRUCTURE SYSTEM (TIS)

VOICE OUTLET, WALL MOUNTED FOR WALL MOUNTED INSTRUMENT. PROVIDE 1

VOICE CABLE. MOUNT 9" FROM WALL SWITCH OUTLET.

VOICE/DATA OUTLET, MOUNTED IN CASEWORK.

VOICE/DATA OUTLET, MOUNTED IN MODULAR FURNITURE.

MULTI SERVICE HAND ACCESS FLUSH FLOOR MOUNTED VOICE/DATA OUTLET.

FOR POWER REQUIREMENTS SEE LEGEND E-001.

VOICE/DATA CONNECTION TO MODULAR FURNITURE, WALL MOUNTED, ROUTE TO

MODULAR FURNITURE OUTLET(S) VIA FLEXIBLE METALLIC CONDUIT. NUMERAL

DENOTES NUMBER OF OUTLETS SERVED.

VOICE CABLE IN CONDUIT TO CORRIDOR CABLE TRAY.

W

CW

MF

T

T

DATA CABLE IN CONDUIT TO CORRIDOR CABLE TRAY.D

VOICE BACKBONE CABLE IN CONDUIT.TB

DATA BACKBONE CABLE IN CONDUIT.DB

VOICE/DATA CABLE IN CONDUIT TO CORRIDOR CABLE TRAY.VD

VOICE/DATA SYSTEM BACKBOARD, SIZE AS SHOWN OR 48" x 48" x 3/4", MINIMUM AC

PLYWOOD, PAINT WITH TWO COATS GRAY FIRE RETARDANT ENAMEL PAINT.

CONNECTOR BLOCK.

VDBB

CROSS CONNECT FIELD.

BASKET TYPE CABLE TRAY IN CORRIDORS. LADDER TYPE CABLE TRAY IN

COMMUNICATIONS ROOMS. TRAYS SHALL HAVE 4" DEPTH. 'CT-12' DENOTES CABLE TRAY

12" WIDE.

RELAY EQUIPMENT RACK.

WIRE MANAGER, RACK MOUNTED.

PLUG STRIP, RACK MOUNTED.

FIBER OPTIC CONNECTOR PANEL, RACK MOUNTED, 12-PORT.

PATCH PANEL, UNSHIELDED TWISTED PAIR CABLES, RACK MOUNTED. 48 PORT.

CONNECTOR BLOCK WITH PROTECTORS.

LP

REQR

WM

PS

FOCP-12

UTTP-48

TMGB MAIN GROUND BUS, 24 CIRCUIT 400A PANELBOARD NEUTRAL BUS, ATTACHED TO

WALL WITH SCREWS.

TGB GROUND BUS, 24 CIRCUIT 225A PANELBOARD NEUTRAL BUS, ATTACHED TO WALL

WITH SCREWS.

BSG CONNECT TO BUILDING SERVICE GROUND WITH 1#8 GROUND - 3/4"C, UNLESS

OTHERWISE NOTED.

6G 1#6 GROUND CONDUCTOR IN CONDUIT. SIZE CONDUIT AS PER NEC.

WAP DATA OUTLET, MOUNTED ABOVE CEILING FOR WIRELESS ACCESS POINT, PROVIDE

2 DATA CABLES. PROVIDE 48" SLACK FOR EACH CABLE ABOVE CEILING.

VOICE/DATA OUTLET, MOUNTED 6" ABOVE COUNTERTOP.CT

DATA OUTLET, MOUNTED BEHIND FLAT PANEL TV, PROVIDE 1 DATA CABLE.TVF

VOICE/DATA OUTLET, MOUNT BEHIND FLAT PANEL TV, PROVIDE 3 DATA AND 2

VOICE CAT 6 CABLES, 1 1/4"C.

VTC

T

TELECOM JUNCTION BOX, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.T

TELECOM JUNCTION BOX, FLUSH FLOOR MOUNTED.

T VOICE/DATA CONNECTION TO MODULAR FURNITURE, FLUSH FLOOR MOUNTED,

ROUTE TO OUTLET(S) SHOWN ON PLANS VIA FLEXIBLE METALLIC CONDUIT.

NUMERAL DENOTES NUMBER OF OUTLETS SERVED.

FUTURE RELAY EQUPMENT RACK.

TELECOM JUNCTION BOX FOR QUEUING SYSTEM, MOUNTED AT 18" AFF UNLESS

OTHERWISE NOTED. PROVIDE 1" CONDUIT FROM BOX TO QUEUING TERMINAL CABINET

LOCATED IN PHARMACY.

T Q

CT-12

110 BLOCK, RACK MOUNTED, 100-PAIR SHOWN.110-100

CONDUIT/CIRCUIT ROUTED OVERHEAD.

CONDUIT/CIRCUIT ROUTED BELOW SLAB.

T

VOICE/DATA CONNECTION TO MODULAR FURNITURE, CEILING MOUNTED, ROUTE TO

MODULAR FURNITURE OUTLET(S) VIA METALLIC FLEX CONDUIT. NUMERAL DENOTES

NUMBER OF OUTLETS SERVED.

TOILET LAVATORY EMERGENCY STATION WITH PULL CORD TO WITHIN 2" OF

FLOOR, WALL MOUNTED.

NURSE CALL SYSTEM

PATIENT SINGLE BEDSIDE STATION, PULL CORD, WALL MOUNTED.

NURSE CALL CIRCUIT IN CONDUIT, NUMBER OF CONDUCTORS AS REQUIRED BY

SYSTEM MANUFACTURER.

N

NC

EL

N

PS

N CORRIDOR DOME LIGHT, CEILING MOUNTED, 'CB' = WITH CODE BLUE, NUMERAL

DENOTES ZONE LIGHT ASSOCIATED WITH DOME LIGHT.

N CORRIDOR DOME LIGHT, WALL MOUNTED, 'CB' = WITH CODE BLUE, NUMERAL

DENOTES ZONE LIGHT ASSOCIATED WITH DOME LIGHT.

NCA NURSE CALL ANNUNCIATOR, WALL FLUSH MOUNTED

NCCE NURSE CALL CONTROL EQUIPMENT, WALL MOUNTED

NCTC NURSE CALL TERMINAL CABINET, WALL MOUNTED

PUSH BUTTON STATION, WALL MOUNTEDN

CODE BLUE STATION, WALL MOUNTED.N

CB

STAFF ASSIST, WALL MOUNTED.N

SA

N CORRIDOR ZONE LIGHT, 'CB' = WITH CODE BLUE, NUMERAL DENOTES DOME LIGHTS

ASSOCIATED WITH ZONE LIGHT.

N CORRIDOR DOME LIGHT, WALL MOUNTED, 'CB' = WITH CODE BLUE, NUMERAL

DENOTES DOME LIGHTS ASSOCIATED WITH ZONE LIGHT.

Z

Z

SHOWER EMERGENCY STATION WITH PULL CORD TO WITHIN 2" OF FLOOR, WALL

MOUNTED ABOVE SHOWER HEAD.

N

ES

8" SPEAKER RECESSED, CEILING MOUNTED.

PUBLIC ADDRESS SYSTEM

WALL MOUNTED PUBLIC ADDRESS SYSTEM RACK.

SPEAKER CIRCUIT IN CONDUIT. CONDUCTORS AS REQUIRED BY SYSTEM

MANUFACTURER.

PAGING INTERFACE, RACK MOUNTED.

AMPLIFIER, OUTPUT WATTAGE AS SHOWN, RACK MOUNTED.

S

PAWR

PATC TERMINAL CABINET, SIZE AS NOTED OR 6" x 6" x 4" MINIMUM, WITH WOOD

BACKBOARD, HINGED DOOR AND TERMINAL STRIPS.

P

PI

S V VOLUME CONTROL, WALL MOUNTED.

TELEVISION OUTLET, WALL MOUNTED, MOUNT BEHIND FLAT PANEL.

TELEVISION DISTRIBUTION SYSTEM (TVDS)

AMPLIFIER, WALL MOUNTED.

LINE TERMINATOR, MOUNTED IN JUNCTION BOX, ABOVE ACCESSIBLE CEILING.

SPLITTER/MIXER, INPUT-OUTPUT CONNECTOR RATIO AS SHOWN, MOUNT IN

JUNCTION BOX ABOVE ACCESSIBLE CEILING.

DISTRIBUTION TAP, NUMBER DENOTES NUMBER OF TAPS, 12 TAPS AS SHOWN.

GROUNDING BLOCK, CONNECT TO BUILDING GROUND.

EQUIPMENT RACK, FLOOR MOUNTED.

TV

TV

TV

TVER

1:4

TVBB CATV BACKBOARD

TV CIRCUIT IN CONDUIT.

DATA OUTLET WITH TWO CAT 6 CABLES, CEILING OR WALL MOUNTED. 'WP' =

PROVIDE WEATHERPROOF BOX. MOUNT AT HEIGHT SHOWN ABOVE FINISHED

GRADE (EXTERIOR) OR ABOVE FINISHED FLOOR.

VIDEO SURVEILLANCE SYSTEM

TERMINAL CABINET FOR CCTV SYSTEM, BY OTHERS. CCTC

CONDUIT WITH PULL STRING AND JUNCTION BOX FOR MONITOR, MOUNT AT 18"AFF

UNLESS OTHERWISE NOTED.

CCTV CONDUIT WITH PULL STRINGCC

CARD ACCESS SYSTEM

CARD READER, WALL MOUNTED. 'WP' DENOTES WEATHERPROOF.CR

EXIT BUTTON, WALL MOUNTED.EB

ELECTRIC STRIKE. COORDINATE WITH DOOR HARDWARE.ES

CABB CARD ACCESS BACKBOARD, PAINT WITH TWO COATS GRAY FIRE RETARDANT

ENAMEL PAINT.

CARD ACCESS CONTROLLER, WALL MOUNTEDCAC

MONITOR DESK MOUNTED

TERMINAL CABINET, SIZE AS NOTED OR 6" x 6" x 4" MINIMUM, WITH WOOD

BACKBOARD, HINGED DOOR AND TERMINAL STRIPS.

CATC

CA CARD ACCESS SYSTEM IN CONDUIT. CONDUCTORS AS REQUIRED BY

SYSTEM MANUFACTURER.

WIRELESS DURESS ALARM DEVICE.

DURESS SYSTEM

DA

WIRELESS DURESS TRANSMITTER/RECEIVER. PROVIDE TRANSMITTER/REPEATER

SYSTEM FOR DURESS ALARMS THROUGHOUT THE CLINIC FOR 100% COVERAGE

INSIDE THE FACILITY.

DAT

PROVIDE JUNCTION BOX FOR INTRUSION DETECTION PANEL, DEVICE BY

OTHERS.

INTRUSION DETECTION SYSTEM

PROVIDE JUCNTION BOX FOR PASSIVE INFRARED DETECTOR, CEILING MOUNTED,

DEVICE BY OTHERS.

IDP

PI

IDS CIRCUIT CONSISTING OF CONDUIT WITH PULL STRING.ID

GB PROVIDE JUNCTION BOX FOR GLASS BREAK SENSOR, CEILING MOUNTED, DEVICE

BY OTHERS.

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

RI

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

1:4 8 A

M

1/8" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

LE

GE

ND

EY001

MBA MBA RMH

18267522

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

PROFESSIONAL

E RN G I N E E

ABBREVIATIONS

A AMPERES

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AMP AMPLIFIER

BSG BUILDING SERVICE GROUND

C CONDUIT

CATV COMMUNITY ANTENNA TELEVISION (CABLE)

CIRC CIRCUIT

CL CEILING MOUNTED

COMM COMMUNICATIONS

CT COUNTER TOP

CW CASEWORK

DB DIRECT BURIED

DDC HVAC DIGITAL CONTROLLER

EC EMPTY CONDUIT WITH PULL STRING

EM EMERGENCY

EX EXISTING TO REMAIN

FACP FIRE ALARM CONTROL PANEL

FATC FIRE ALARM TERMINAL CABINET

FUT FUTURE

GND GROUND

MH MANHOLE

MTG HT MOUNTING HEIGHT

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OFOP OPTICAL FIBER OUTSIDE PLANT

OFR OPTICAL FIBER RISER

OSP OUTSIDE PLANT

PET PROTECTED ENTRANCE TERMINAL

PR PAIR

REQ'D REQUIRED

REQR RELAY EQUIPMENT RACK

SIM SIMILAR

SMD SURFACE MOUNTED

SMF SINGLE-MODE FIBER

TIS TELECOMMUNICATIONS INFRASTRUCTURE SYSTEM

TPH TWISTED PAIR HORIZONTAL

TPR TWISTED PAIR RISER

TPOP TWISTED PAIR OUTSIDE PLANT

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

UTP UNSHIELDED TWISTED PAIR

VD VOICE/DATA

VDBB VOICE/DATA BACKBOARD

WG WIREGUARD

WP INDICATES WEATHERPROOF EQUIPMENT

CARD ACCESS SYSTEM:

CONTROL PANEL (TO TOP OF DISPLAY) ............................. 66"

CARD READERS ...................................................................... 44"

DURESS SWITCH OUTLET BOX ..............................................18"

TELECOMMUNICATIONS INFRASTRUCTURE SYSTEM (TIS):

DESK OUTLETS ....................................................................... 18" WALL OUTLETS ....................................................................... 54"

COUNTER TOP OUTLET .......................................................... 6"

GROUND BUS ........................................................................... 80" CABLE RACK ............................................................................ 84"

NURSE CALL SYSTEM:

BEDSIDE STATION ................................................................... 48" TOILET STATION ...................................................................... 30"

DOME LIGHT (WALL MOUNTED) .............................................90"

MASTER STATION (TO TOP OF DISPLAY) ..............................66"

TELEVISION DISTRIBUTION SYSTEM:

TELEVISION OUTLET (LOW) ....................................................18"

TELEVISION OUTLET (FLAT PANEL) (OUTLET SHALL

BE LOCATED BEHIND TELEVISION AND ADJACENT

TO POWER OUTLET) ........................................................... 72"

WALL MOUNTED EQUIPMENT (AMPLIFIER,

DISTRIBUTION EQUIPMENT, ETC) ..................................... 48"

PUBLIC ADDRESS SYSTEM:

WALL MOUNTED CABINETS .................................................... 60"

INTRUSION DETECTION SYSTEM:

CONTROL PANEL (TO TOP OF DISPLAY).................................66"

KEYBOARD ............................................................................... 56"

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

1:5 3 A

M

1/8" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

N

OT

ES

EY002

MBA MBA RMH

18267523

02/28/18

1 SEE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR MATERIAL AND METHOD REQUIREMENTS FOR ELECTRICAL BOXES, CONDUITS, FITTINGS, MOUNTING, ETC.

2 FLEXIBLE CONDUIT MUST BE INSTALLED OUT-OF-DOORS, IN ANY MECHANICAL EQUIPMENT ROOM, OR IN NORMALLY WET AREAS. 'MC' CABLE IS NOT ALLOWED

WITH THE EXCEPTION OF USE IN FURNITURE WHIPS & LIGHTING WHIPS.

3 COORDINATE WITH ALL TRADES FOR SPACE REQUIREMENTS IN MECHANICAL ROOMS, CORRIDORS, SHAFTS, ABOVE CEILINGS, ETC. SPACES ABOVE

TELECOMMUNICATIONS CABINETS SHALL NOT HAVE PIPES AND/OR CONDUITS IN THEM.

4 FOR EXACT LOCATIONS OF MECHANICAL EQUIPMENT, SEE MECHANICAL PLANS. FOR EXACT LOCATIONS OF ELECTRICAL EQUIPMENT, SEE ELECTRICAL

PLANS.

5 THE LOCATION OF DEVICES IN MECHANICAL ROOMS AND ELECTRICAL ROOMS, ETC. ARE SHOWN DIAGRAMMATICALLY ONLY. DEVICES SHALL BE INSTALLED

SO AS TO COORDINATE WITH ALL TRADES.

6 PLACE SPEAKERS IN MECHANICAL AND ELECTRICAL ROOMS FOR MAXIMUM SOUND DISTRIBUTION.

7 PROVIDE FLEXIBLE CONDUIT FOR ALL CONDUITS PASSING THROUGH EXPANSION JOINTS. SEE ARCHITECTURAL DRAWINGS FOR EXPANSION JOINT

LOCATIONS.

8 SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF ALL CEILING MOUNTED EQUIPMENT.

9 CONTRACTOR MUST VERIFY AND COORDINATE ALL MOUNTING HEIGHTS OF ALL DEVICES MOUNTED IN CASEWORK OR IN OR ABOVE COUNTERS WITH

SPECIFIC EQUIPMENT FURNISHED.

10 OUTLET BOXES (VOICE, DATA, TELEPHONE, ETC.) OVER 16 SQUARE INCHES IN SMOKE AND FIRE WALLS MUST BE ENCLOSED WITH A FIVE SIDED ENCLOSURE

WITH SAME CONSTRUCTION AS WALL SYSTEM. WHERE OUTLET BOXES ARE ON OPPOSITE SIDES OF A FIRE WALL THERE MUST BE A 24" HORIZONTAL SEPARATION BETWEEN THEM OR BOXES SHALL BE PROTECTED WITH UL LISTED FIRE RESISTANT MATERIAL ON 5 SIDES. IF OUTLET BOXES ON PLANS ARE SHOWN AT EXISTING LOCATIONS IN FIRE WALLS BUT THERE IS LESS THAN 24" OF SEPARATION THE CONTRACTOR SHALL RELOCATE ONE OR BOTH OUTLETS

TO ACHIEVE THE MINIMUM 24" OF SEPARATION REQUIRED.

11 DO NOT MOUNT OUTLETS BACK TO BACK.

12 ALL TELECOMMUNICATION CONDUITS SHALL BE 1" MINIMUM, UNLESS OTHERWISE NOTED.

13 MAINTAIN N.E.C. MINIMUM CLEARANCE IN FRONT OF ALL DEVICES AND OTHER COMMUNICATIONS EQUIPMENT. DETERMINE PROPER CLEARANCE BEFORE

INSTALLATION. DIMENSIONS OF EQUIPMENT SHOWN ARE BASED ON A PARTICULAR MANUFACTURER. IF DIMENSIONS OF EQUIPMENT FURNISHED DIFFER FROM THOSE ON THE DRAWINGS, CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ALL EQUIPMENT FITS IN THE ROOM OR SPACE ALLOCATED WITH

PROPER CLEARANCE.

14 NO CONDUIT SHALL PASS THROUGH ELEVATOR HOIST WAY OR ELEVATOR MACHINE ROOM UNLESS IT SPECIFICALLY SERVES EQUIPMENT IN THAT ROOM.

15 PRIOR TO ROUGH-IN, CONTRACTOR MUST PROVIDE SCALED WALL ELEVATIONS WHERE ALL CABINETS, RACKS, TRUNK CABLES, ETC. ARE INSTALLED IN OTHER

THAN COMMUNICATIONS ROOMS FOR APPROVAL.

16 ALL UNDERGROUND CONDUIT RUNS ENTERING THE BUILDING SHALL BE SEALED TO PREVENT ENTRANCE OF MOISTURE, GASES, AND RODENTS.

17 CONTRACTOR MUST VERIFY AND COORDINATE ALL CONNECTIONS TO EQUIPMENT WITH SPECIFIC EQUIPMENT FURNISHED.

18 CONDUIT FOR COMMUNICATIONS SYSTEMS SHALL BE RUN OVERHEAD UNLESS NOTED OTHERWISE.

19 ALL RECESSED MOUNTED CABINETS SHALL HAVE FOUR 1" EMPTY CONDUITS STUBBED ABOVE THE ACCESSIBLE CEILINGS.

20 CONNECTIONS TO MECHANICAL AND MEDICAL EQUIPMENT ARE BASED ON A PARTICULAR MANUFACTURER. IF CONNECTIONS TO EQUIPMENT DIFFER FROM

THAT SHOWN ON THE DRAWINGS, CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONNECTIONS AS REQUIRED.

21 MOUNT WALL PHONE BOXES 6" FROM LIGHT SWITCHES TO PROVIDE SPACE FOR TELEPHONE INSTRUMENT.

22 ALL CONDUIT MUST BE CONCEALED IN FINISHED WALLS OR ABOVE FINISHED CEILINGS UNLESS INDICATED OTHERWISE.

23 CONTRACTOR MUST COORDINATE WITH ALL OTHER TRADES WHEN INSTALLING CABLE TRAY SYSTEM. MAINTAIN ALL CLEARANCES PER TIA/EIA 569.

24 ALL EMPTY AND SPARE CONDUITS SHALL CONTAIN A PULL STRING.

25 MOUNTING HEIGHTS OF WALL OUTLETS ABOVE FINISHED FLOOR SHALL BE AS INDICATED IN THE FOLLOWING TABLE UNLESS NOTED OTHERWISE ON THE

PLANS (MOUNTING HEIGHTS ARE TO CENTERLINE OF DEVICE):

TELECOMMUNICATIONS NOTES

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

W

W

W

TGB

TVBB

VDBB

CCTC CATC

PATC

NCTCA

REQR-C

REQR-B

REQR-A

(3) FUTURE REQR

LOCATIONS (TYP)

EY101

B1

EY101

D5

EY101

A1

EY101

C5

THIS BOUNDED AREA IS

TO BE FED FROM

TELECOM ROOM 1070

THIS BOUNDED AREA IS

TO BE FED FROM

TELECOM ROOM 1012

THIS BOUNDED AREA IS

TO BE FED FROM

TELECOM ROOM 1124

THIS BOUNDED AREA IS

TO BE FED FROM

TELECOM ROOM 1133

A

B

C

D

G

H

J

K

L

9 10

M

12 14 15 16E

F

TGB

NCTC

TVBB

VDBB

CCTC

CATC

D

REQR-C

REQR-B

REQR-A

FIRE ALARM

RFCU-2

TGB

NCTCCATC

TVBB

VDBB

PATC

CCTC L

REQR-A

REQR-B

REQR-C

IDTC

FIRE ALARM

RFCU-1

TMGB

CATCCCTCNCCE

VDBB

PAWR

TVER

L

REQR-A

REQR-B

REQR-C

TVBB

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

N

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

N

0 10'

1/16" = 1'-0" GRAPHIC SCALE

20' 40' 60'

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:0 9 A

M

As indicated

TE

LE

CO

MM

UN

IC

AT

IO

NS

C

OM

PO

SI

TE

P

LA

N

EY101

MBA MBA RMH

18267524

02/28/18

SCALE: 1/4" = 1'-0"

TELECOM ROOM 1070B1

SCALE: 1/16" = 1'-0"

TELECOM COMPOSITE PLAN - FIRST FLOORA2

SCALE: 1/4" = 1'-0"

TELECOM ROOM 1012D5

SCALE: 1/4" = 1'-0"

TELECOM ROOM 1124A1

SCALE: 1/4" = 1'-0"

TELECOM ROOM 1133C5

0 2' 4' 8'

SCALE: 1/4"=1'-0"

0 2' 4' 8'

SCALE: 1/4"=1'-0"

OSP

CONDUITS

NOTE: SEE BLOCK PLANS

FOR LADDER TRAY LAYOUTS

IN EACH TELECOM ROOM.

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

CR

SV

S

S

S S

S S

WW

CR

TV

W

W

N Z

W W

W W

CRCR

T T

T T

EXAM

EXAM

EXAM

EXAM

TEAM

MECH.

EQUIP.

CLEAN

1038CLEAN

4 5

A

B

CT-12 CT-12

CT-12

CT-12

MECH DDC PANELS

SEE DOOR DETAIL 'B'

SHEET EY604

WAP

WAPWAP

WAP

SEE DOOR DETAIL 'A'

SHEET EY604

WP

TV

NC

A

WP

+18.0'

+30"AFF+30"AFF

+30"AFF +30"AFF

SEE DOOR DETAIL 'B'

SHEET EY604

CORR

CORR

CORR

MFMF

MF

MF

DAT

MECH DDC PANEL

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:1 6 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

1A

EY101-1A

MBA MBA RMH

18267525

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

N

EL

S V

TV

SV

W

S

S

S S S

SS

N

S S

T

T

W T

T

TV

TV

TT

TV

N Z

W W

CR

T T

T T

COPY

ELECT.

AUDIO

EXAM

EXAM

TEAM

AUD OFF

SR OFF

SOIL

CONF

1026JC

RN MGR

LPO

TV

CL

6 7 8

A

B

CT-12 CT-12 CT-12

CT-12

CT-12

WAP WAP

WAP

WAP

1-1"EC

S TLT

+64"

+64"

+64"

TV

TV

1-1"EC

TV

NC

A

+30"AFF

+30"AFF

MGR OFF

SEE DOOR DETAIL 'B'

SHEET EY604

CORR

CORR

CORR

MFMF

MF

MF

MOUNT AT 9'-0" AFF

DAT

DAT

DAT

DAT

CT

CT

CT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:2 3 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

1B

EY101-1B

MBA MBA RMH

18267526

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

TV

EL

N

EL

CR

SSS

S

S S

N N

N

SA

N

SA

N

N

CR

N Z

S V

S

N

CB

N

W W

W W

CONSULT

OB/HY

SCREEN

SCREEN

P TLT

P TLT

TV

SEE DOOR DETAIL 'B'

SHEET EY604

NC

A

4 5

C

D

CT-12 CT-12

CT-12 CT-12

TEAM

WAP

WAP

FOR CCTV

CAMERAS

CB

IMM/OBS

FOR CARD

ACCESS

+30"AFF+30"AFF

+30"AFF +30"AFF

DA DA

RECEP

PAT RECS

CORR

CORR

CORR

LOBBY

MFMF

MFMF

DAT

DATDAT

MOUNT AT 3'-6"

N

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

N

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:2 8 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

1C

EY101-1C

MBA MBA RMH

18267527

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

N N

CR

S

SSS

S

S

S

N

N

CB

N

CB

N

SA

N

N Z

W

W W

W

W

W

AUDIO

EXAM

SCREEN

OH NUR

VISION

1014LACT

BEHAV OFF

COMM.

OH EXAM

OH EXAM

SEE SHEET EY101

FOR COMM ROOM

EQUIPMENT

CT-18

SEE DOOR DETAIL 'B'

SHEET EY604

FOR REFRIG/FRZR

MONITORING,

MOUNT AT 7'-0" AFF.

WP

6 7 8

C

D

CT-12

CT-12

CT-12 CT-12

CT-12

TEAM

WAP

WAP

CB

SEE DOOR DETAIL 'B'

SHEET EY604

E

WP

+13.5'

+30"AFF

+30"AFF

+30"AFF

+30"AFF

IMMUN

DA

+30"AFF

CT-12

CT-12

CT- 12

CT- 12

CORR

CORR

CORR

MFMF

MFMF

MOUNT AT 9'-0" AFF.

DAT DAT

N

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

N

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:3 4 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

1D

EY101-1D

MBA MBA RMH

18267528

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

S V

N

EL

CR

SV

W

CR

S

S

S S S

S S S

N

S S

TV

TV

W

N Z

N Z

N Z

W W

W W

W

W

CR

T T

T T

EXAM

ELECT.

EXAM

EXAM

TEAM

EXAM

EXAM

S TLT

COMM.

SR OFF

SR OFF

1052 SOIL

CT-12

SEE SHEET EY101

FOR COMM ROOM

EQUIPMENT

CT-18

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

WP

21 3

A

B

CT-12 CT-12

CT-12 CT-12

WAP

WAP WAP

WAPWAP

TV

CT-12

TV

NC

A

7 8

WP

+19.0'

+30"AFF

+30"AFF

+30"AFF

+30"AFF

+30"AFF

STF LOUNGE-1

1072-1 SEE DOOR DETAIL 'B'

SHEET EY604

CT-12

CT-12

CT- 12

CT- 12

CORR

CORR

CORR

CORR

10852

MFMF

MF

MF

DAT

DAT

DAT DAT

N

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

N

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:3 9 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

2A

EY101-2A

MBA MBA RMH

18267529

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

NN

N

EL

N

EL

CR

SSS

S

S

S S S

N

N

N N

N N

N Z

N Z

N Z

N

CB

N

CB

N

SA

N

N

CB

N

N

N

N

CB

CR

W W

W

W

W W

W

W

W

W

TV

TV

SCREEN

EKG

EXAM

SCREEN

TREAT

P TLT

OB/HY

EXAM

TREAT

TELEHLTH

PAT ED

BEHAV

CT-12

ISO TLT

WP

SEE DOOR

DETAIL 'B'

SHEET EY604

21 3

C

D

CT- 12

CT-12 CT-12

CT-12

TEAM

WAP

WAP

WAP WAP

CBCB

CT-12

DA

CB

JC

6 7

CB

WP

+13.5'

+30"AFF

+30"AFF

+30"AFF

+30"AFF

+30"AFF

+30"AFF

+30"AFF

+30"AFF

+30"AFF

SEE DOOR DETAIL 'B'

SHEET EY604

ISO

+30"AFF

TV

CORR

CORR

CORR

CORR

LOBBY

TV

MFMF

MFMF

DAT DAT

DATDAT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:4 1 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

2B

EY101-2B

MBA MBA RMH

18267530

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

T

T

T

S

S

S

S S

S

JT T

SEE DOOR DETAIL 'A' SHEET

EY604. COORDINATE

INTERFACE WITH AUTOMATIC

DOOR PROVIDER.

WP

21 3

D

G

H

FOR QUEUING KIOSK

MOUNT AT 14'-6"

AFF FOR

WIRELESS

ACCESS POINT

Q

E

F

TV Q

1"C WITH CABLING AS

REQUIRED, ROUTE TO CABLE

TRAY VIA COLUMN FURRING

WP

+13.5'

LOBBY

WP

+13.5'

QTV

DAT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:4 6 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

3A

EY101-3A

MBA MBA RMH

18267531

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

T T

T T

S

S

S S

S

S

S

JT T

SEE DOOR DETAIL 'A' SHEET

EY604. COORDINATE

INTERFACE WITH AUTOMATIC

DOOR PROVIDER.

WP

4 5

D

G

H12

MOUNT AT 15'-6"

AFF FOR

WIRELESS

ACCESS POINT

MOUNT AT

15'-6" AFF FOR

WIRELESS

ACCESS POINT

E

F

MOUNT AT

15'-6" AFF FOR

WIRELESS

ACCESS POINT

TVQ

Q

FOR QUEUING KIOSK

Q

FOR QUEUING KIOSK

1"C WITH CABLING AS

REQUIRED, ROUTE TO CABLE

TRAY VIA COLUMN FURRING

WP

+8.0'

LOBBY

TVQ

DAT

NOTE 1

NOTE 1

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:5 1 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

3B

EY101-3B

MBA MBA RMH

18267532

02/28/18

NOTES:

1. MOUNT TV AND VOICE/DATA OUTLET FOR THE M1880A

MESSAGE BOARD AT 5'-0" TO CENTER AFF. COORDINATE

WITH MILLWORK AND ARCHITECTURAL SHEETS.

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

N

EL N

EL

SSSS

S

S

N

EL

N

EL

CR

CR

N N

N N Z

T T T

N N

N

NN

N

CB

N

CB

N

CB

N

CBN

T

N

T

N

SA

T T T

W

W

CR

T

N

SA

T

T T

T

T T

T T

T

T TT

T

N

SA

N

LAB WORK

1118 PHLEBOTOMY

S TLT

RECEP.

RADIOLOGY

DRESS

CT-12

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

NC

A

SP TLT

FOR REFRIG/FRZR

MONITORING,

MOUNT AT 7'-0" AFF.

FOR IDS WINDOW

CONTACT (TYP OF 4)

PIPI

PI

PI

RECESSED QUEUING

TERMINAL CABINET,

MOUNT AT 84" AFF.

G

H

J

K

9 10

MFMF

WAP WAP WAP

WAP

WAP

WAP

WAP

WAP

CT

CT

CB

CB

FOR IDS DURESS

FOR QUEUING

SCREEN, MOUNT

AT 60" AFF

CL

M7280

Q TV 5

PHARMACY

MF

FOR IDS DURESS

(TYP OF 4)

GB

GB

GB

PUB TLT(F)

VEND.

LOBBY

SUBWAIT

CONSULT

SEE DOOR DETAIL 'B'

SHEET EY604

MF MF 2

MF MF

PROVIDE TWO JUNCTION BOXES ABOVE

CEILING, ROUTE COMM CABLES TO

OUTLETS MOUNTED IN FURNITURE.

MF MF

PROVIDE JUNCTION BOX ABOVE

CEILING, ROUTE COMM CABLES TO

OUTLETS MOUNTED IN FURNITURE.

PROVIDE JUNCTION BOX ABOVE

CEILING, ROUTE COMM CABLES TO

OUTLETS MOUNTED IN FURNITURE.

MF MF 2

PROVIDE THREE JUNCTION

BOXES ABOVE CEILING, ROUTE

COMM CABLES TO OUTLETS

MOUNTED IN FURNITURE.2

MF

MF

MF

MF

MF

MF

MF

PROVIDE JUNCTION BOX

ABOVE CEILING, ROUTE

COMM CABLES TO OUTLETS

MOUNTED IN FURNITURE.

MF MF MF MF

MF

MF

PROVIDE JUNCTION BOX ABOVE

CEILING, ROUTE COMM CABLES TO

OUTLETS MOUNTED IN FURNITURE.

FOR REFRIGERATOR

TEMPERATURE MONITORING

DA

DA DA DA DA

DAT DAT

DAT

DAT

CT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

2:5 8 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

4A

EY101-4A

MBA MBA RMH

18267533

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

TV

S V

S S S

S

W S V

S

CR

CR

CR

T

T

T

W

W

T

W

W

T T T

T

T

N

SA

TR/HOLD

STF LOUNGE

BRK/DN

PHARMACY

ELECT.

STF LKR(F)

TV

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

STF LACT

WP

GB PI

PI

PI

FOR PHARMACY

CAMERAS

K

L

9 10

CT-12

FOR IDS KEYPAD

WAP WAP

WAP

FOR IDS

WINDOW

CONTACT

FOR IDS DURESS

LKR.TLT(F)

1120-1

Q

FOR QUEUING

COMPUTER

GB

GB

GB

LAB WORK

CORR

MF

MF

MF

MF

PROVIDE JUNCTION BOX ABOVE

CEILING, ROUTE COMM CABLES TO

OUTLETS MOUNTED IN FURNITURE.

MF

MF 2

2 MFMF

MF

PROVIDE JUNCTION BOX ABOVE

CEILING, ROUTE COMM CABLES TO

OUTLETS MOUNTED IN FURNITURE.

DA

MOUNT AT 7'-0" AFF.

JC

DAT

DAT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:0 3 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

4B

EY101-4B

MBA MBA RMH

18267534

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

N

EL

N

EL

N

EL

S

S

S S

S S

S

S

N

EL

N

N

EL

N

EL

N

ES

N

ES

N

N

N

N N

N N

N N

N N N

N

N

N Z

N

N

N

SA

N

N

CB

N

CB

N Z

N Z

N Z

N Z

W

W

W

WW

W W

W

CR

CR

T N

SA

W

SPINAL

OCC THER

TREAT.

EXAM

PT. OFF

CORR

PAT/LKR(F)

TREAT

PAT/LKR(M)

EMG

CUBICLES

CABLE TRAY

AT 10'-0"

THIS AREA

P TLT

P TLT

H

J

K

12 14

CT

-1

CT-12

CT-12

CT

-1

CT-12

WAP

WAP

WAP

WAP

CB

CB

DA

CB

CB

RECEP

1 1

1,3,4

DA

CHIRO

LOBBY

CORR

CORR

PUB TLT(M)

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

Q

FOR QUEUING KIOSK

NCA

DAT

DAT

DAT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:0 9 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

5A

EY101-5A

MBA MBA RMH

18267535

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

S S S

S S

S SS

S V N

N

CB

N

CB

N

N N

CB

N N N

T

T

T T

T

TT

T T T T T T

T T

T T T

T

NN

CR

S

H

J

14 15 16

WAP WAP

WAP

WAP

EXERCISE

CB CB CB

1"EC TO CABLE TRAY

VIA COLUMN FURRING

1"EC TO CABLE TRAY

VIA COLUMN FURRING

1"EC TO

CABLE TRAY

VIA CHASE

1"EC TO

CABLE TRAY

VIA CHASE

1"EC TO CABLE TRAY

VIA CHASE

1"EC TO

CABLE TRAY

VIA CHASE

1"EC TO CABLE TRAY

VIA COLUMN FURRING

1,3 1,3 1,3CB1,3CB1,3

CT-12

WP

+14.5'

WP

SEE DOOR DETAIL 'B'

SHEET EY604

LOCATE ADJACENT TO FLOOR

RECEPTACLE SHOWN ON EP

SERIES SHEETS (TYP)

DAT

DAT

DAT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:1 4 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

5B

EY101-5B

MBA MBA RMH

18267536

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

S S S S

CR

W

N

ELN

EL

S V

S

CRCR

W

W

N N

W W W

LPO OFF.

COPY

PROV

PROV

ELECT.

COMM.

FELLOW

SEE SHEET EY101

FOR COMM ROOM

EQUIPMENT

CT-18

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'A'

SHEET EY604

SEE DOOR DETAIL 'A'

SHEET EY604

PROV

MECH.

WP WP

STF LKR(M)

JC

K

L

12 14

CT

-1

CT-12CT-12

MECH DDC PANELS

MECH DDC PANELS

WAP WAP

LKR.TLT(M)

1121-1

S TLT

TEAM

S TLT

WP

+15.0'

WP

+15.0'

CORR

MECH DDC PANEL

DDC WORKSTATION

CT

-1

CT

-1

CT

-1

CT

-1

DAT DAT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:2 6 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

5C

EY101-5C

MBA MBA RMH

18267537

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

S S S

S

S

CR

W

CR

CR

CR

CR

CR

N

CB

N

CB

N

CB

NN

N

W W

W

W W

N N N

CBN

CB

WWWW W

CRCR

CLEAN

TREAT

TREAT

TREAT

TREAT

RECY

SOIL

TREAT

ALC

CORR

SEE SHEET EY101

FOR COMM ROOM

EQUIPMENT

CT-18

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

SEE DOOR DETAIL 'B'

SHEET EY604

EQUIP

MAIN ELECT.

EQUIP

GAS

WP

WP

WP

K

L

M

14 15 16

CT-12

WAP

WAPWAP

JC

MOUNT AT 7'-0" AFF.

WP

+13.5'

WP

+14.5'

COMM.

CORR

CORR

SEE DOOR DETAIL 'B'

SHEET EY604

FACP

CT-12

CT

-1

CT

-1

CT

-1

CT

-1

DAT

KEYPLAN

2A

2B

1A 1B

1D 1C

3A 3B

4A

4B

5A 5B

5C 5D

NN

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:3 2 A

M

1/4" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

P

LA

N

- S

EC

TO

R

5D

EY101-5D

MBA MBA RMH

18267538

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

NOTES:

1. ALL BACKBOARDS SHALL BE 8'-0" HIGH x LENGTH AS SHOWN ON

PLANS. MOUNT BOTTOM OF BACKBOARD AT 8" AFF.

2. PROVIDE THE FOLLOWING GROUDNING:

A. BOUNDING AND GROUNDING SHALL BE CONFIGURED IN

TELECOM ROOMS (UTILIZING GROUNDING BUS BARS WITH STANDOFF

INSULATORS) IN ACCORDANCE WITH BICSI INFORMATION

TRANSPORTATION SYSTEMS INSTALLATION MANUAL (ITSIM) 5TH

EDITION AND ANSI/TIA/EIA-J-STD-607.

B. TELECOM MAIN GROUNDING BUS BAR (TMGB) SHALL BE TIED TO

BUILDING GROUND SOURCE WITH #4/0 AWG WIRE AND APPROPRIATE

TWO-HOLE COMPRESSION CRIMP-TYPE LUG FITTINGS.

C. THE EQUIPMENT RACKS SHALL BE BONDED TO THE TGB/TMGB

USING IRREVERSABLE COMPRESSION CRIMP-TYPE LUGS AND A

SEPERATE GREEN-JACKETED #6 STRANDED COPPER CONDUCTOR.

D. CABLE TRAY AND LADDER TRAY SHALL BE BONDED IN

ACCORDANCE WITH NFPA 70 AND NEMA STANDARD VE 2.

3. PROVIDE GRAY CAT 6 FOR VOICE, BLUE CAT 6 FOR DATA, AND

YELLOW CAT 6 FOR WAPs. PATCH PANELS AND JACKS SHALL MATCH

SAME COLOR SCHEME.

3- 4P

R, UT

P, 1"

C

6- 4P

R, UT

P, 1 1

/4" C

6- 4P

R, UT

P, 1 1

/4" C

3- 4P

R, UT

P, 1"

C

3- 4P

R, UT

P, 1"

C

3- 4P

R, UT

P, 1"

C

3- 4P

R, UT

P, 1"

C

5- 4P

R, UT

P, 1 1

/4" C

1- 4P

R, UT

P, 1"

C

3- 4P

R, UT

P, 1-

1" C

1-

1"

ECVD VD VD VD VD

VD

VD

VD

VD T T T T T DVD

T

T

T T 2 1

CT

6- 4P

R, UT

P, TP

H, 1"

C

VO

IC

E

CA

BL

ES

T O

DA

TA

P

AT

CH

P

AN

EL

S

CT

DA

TA

C

AB

LE

S

TO

DA

TA

P

AT

CH

P

AN

EL

S

W

J

FACP IDP PAWR

TIS OUTLET WIRING NOTES:

1. MAXIMUM OF 2 OUTLETS PER CONDUIT RUN.

2. SIZE CONDUITS AS FOLLOWS:

CABLE COUNT CONDUIT SIZE

1 1" 2 1" 3 1" 4 1" 5 1" 6 1 1/4" 7 1 1/4" 8 1 1/2"

9 OR GREATER NOT ALLOWED

WIRING DETAIL TIS OUTLET WIRING

NO SCALE

SINGLE LINE DIAGRAM - VOICE AND GROUNDING

1- 4P

R, UT

P, TP

H, 1"

C

1- 4P

R, UT

P, TP

H, 1"

C

6-4PR,UTP,1 1/4"C

OUTSIDE PLANT (OSP) 200 PAIR COPPER. SEE SITE PLAN

FOR LOCATION. SPLICE COPPER IN MH-12.9

REQR-A

VDBB

TMGB

OSP

COPPER

1-50PR

3-4/0G

4/0G BSG

TELECOM

RM 1133

2 - 4"C

1 1-50PR COPPER

2 SPARE W/ PULL STRING

1 - 2"C

1 1- 4/0 GROUND

VDBB

REQR-A

TGB

4/0 GROUND

VDBB

50 PR

REQR-A

TGB

2- 4P

R, UT

P, 1"

C D

ROUTE CAT6 FROM BOX

TO MODULAR FURNITURE

DEVICES VIA FLEXIBLE CONDUIT AS

SHOWN ON THE FLOOR PLANS.

VTC

ROUTE CONDUITS TO CABLE

TRAY AND ATTACH TO CABLE

TRAY WITH A UL LISTED GROUND

CLAMP (TYP ALL DEVICES

ROUTED TO CABLE TRAY)

PRIMARY

PROTECTOR

BLOCKS

LP

4/0 GROUND

VDBB

50 PR

REQR-A

TGB

4/0 GROUND

SINGLE LINE DIAGRAM - DATA

VDBB

REQR-B

VDBB

REQR-B

VDBB

REQR-B

VDBB

REQR-B

2 - 4"C

1 3-1" FABRIC INNERDUCTS

A 1-12S SMF & 1-12S MMF

B SPARE W/ PULL STRING

C SPARE W/ PULL STRING

2 SPARE

WM

WM

WM

WM

WM

FOCP-24

UTPP-48

UTPP-48

W M

W M

SPACE FOR

USER

EQUIPMENT

FOCP-24

ELEVATION

TYPICAL REQR-B (DATA)

NO SCALE

WM

110-100

WM

WM

WM

WM

110-100

UTPP-48

UTPP-48

W M

W M

SPACE FOR

USER

EQUIPMENT

ELEVATION

TYPICAL REQR-A (VOICE)

NO SCALE

WM

UTPP-48

WM

WM

WM

WM

UTPP-48

UTPP-48

UTPP-48

W M

W M

SPACE FOR

USER

EQUIPMENT

ELEVATION

TYPICAL REQR-C (DATA)

NO SCALE

REQR NOTES:

1. PROVIDE UTPP AND FOPP AS REQUIRED TO SUPPORT TERMINATIONS OF ALL

VOICE/DATA CABLES SHOWN PLUS 25% FUTURE.

2. MULTI-OUTLET POWER STRIP, 208V, 1PH, MOUNTED IN RACK (TYP).

3. MULTI-OUTLET POWER STRIP, 120V, 1PH, MOUNTED IN RACK (TYP).

GROUNDING LUG (TYP)

TERMINATE ALL CONDUITS WITH NYLON

INSULATED BUSHING. PROVIDE FIRE

STOP AS REQUIRED (TYP)

TO CABLE

TRAY

4/0G

50 PR

TELECOM

RM 1124

TELECOM

RM 1012

TELECOM

RM 1070

TELECOM

RM 1070

TELECOM

RM 1012

TELECOM

RM 1124

TELECOM

RM 1133

2- 4P

R, UT

P, 1 1

/4" C D

WAP

EXISTING

MH-13-007

EXISTING

MH-12-8

EXISTING

MH-12-9

AVAILABLE DUCTAVAILABLE DUCT

EXISTING

MH-13-007

EXISTING

MH-12-8

EXISTING

MH-12-9

AVAILABLE DUCTAVAILABLE DUCT

OUTSIDE PLANT (OSP) 24-STRAND SINGLE MODE OPTICAL FIBER.

SEE SITE PLAN FOR LOCATION. SPLICE FIBER IN MH-12.9.

SPLICE TO EXISTING IN

WEATHERPROOF ENCLOSURE

SPLICE TO EXISTING IN

WEATHERPROOF ENCLOSURE

NOTE 2 NOTE 3

3- 4P

R, UT

P, 1"

C

6- 4P

R, UT

P, 1 1

/4"

CVD VD

T

T

2- 4P

R, UT

P, 1"

C D

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:3 6 A

M

12" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

S

IN

GL

E

LIN

ES

EY601

MBA MBA RMH

18267539

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

VDBB

PATC

VENT

PI

AMP

VENT

VENT

ELEVATION PAWR

NO SCALE

VDBB

PATC

TELECOM

RM 1133

VDBB

PAWRPATC

P

P

P P

PUBLIC ADDRESS SYSTEM -

SINGLE LINE DIAGRAM

MANUFACTURERS

RECOMMENDED WIRING IN

2"C MINIMUM (TYP)

NTS

TVBB

TV

TVBBVDBB

HEADEND

EQUIPMENT

BY VENDOR

TVER

TV

TV

TELEVISION DISTRIBUTION SYSTEM -

SINGLE LINE DIAGRAM

1 RG-11, 2"C (TYP)

NTS

TV

1-2"EC STUBBED OUT

5'-0" FOR CABLE PROVIDER

TGB

8 8

TV

TV

TV 1 - RG6, 1"C (TYPICAL)

TV

TV

CL

SEE FLOORPLANS FOR

EXACT QUANTITY AND

LOCATIONS OF OUTLETS

DETAIL -

TYPICAL TVBB

NO SCALE

CONNECT EACH TV OUTLET TO A

SINGLE PORT.

TVBB

(TYPICAL)

PLUG STRIP IN

REAR OF RACK

MOUNT PI ON

REAR OF VENT

PANEL

S SP

S SP

PAWR

PHARMACY SPEAKERS

FOUR ZONE

PAGE INTERFACE

SPARES/ZONES AS

REQ'D

3-7

PI

FROM VDBB

(PAGING ZONES)

FROM VDBB

(ALL CALL)

T

T

BLOCK DIAGRAM PAWR

NO SCALE

VOX

250W S-L

VDBB

PATC

TVBB

TV

TV

TELECOM

RM

VDBB

PATC

TYPICAL ALL SPEAKERS,

EACH ZONE, EACH PATC.

SEE FLOOR PLANS FOR

QUANTITY AND LOCATION.

P P

S S

P

S V

DETAIL -

TYPICAL PATC

NO SCALE

TERMINATE ALL CONDUITS WITH NYLON

INSULATED BUSHING. PROVIDE FIRE

STOP AS REQUIRED (TYP)

TELECOM

RM 1124

TELECOM

RM 1012

TELECOM

RM 1070

TELECOM

RM 1133

TELECOM

RM 1124

TELECOM

RM 1012

TELECOM

RM 1070

P

S

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:4 1 A

M

12" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

S

IN

GL

E

LIN

ES

EY602

MBA MBA RMH

18267540

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

64445-101-014/015

LABELING NOTES:

1. THE LABELING EXAMPLE SHOWN ABOVE IS BASED ON THE FOLLOWING DOCUMENT: CAMP PENDLETON

REQUIREMENTS SUPPLEMENT MCIWEST G-6 TELECOMMUNICATIONS REQUIREMENTS SECTION 271500 (ISP)

OCTOBER 17, 2014. COORDINATE OUTLET LABELING WITH BASE G-6.

2. LABEL BOTH ENDS OF THE VOICE AND DATA CABLES ACCORDINGLY (AT THE OUTLET AND IN THE SERVING COMM ROOM). LABEL THE SURFACE OF THE WAP ACCORDING TO THE APPROPRIATE PATCH PANEL LETTER AND CABLE

NUMBER. COORDINATE LABELING WITH BASE G-6.

VOICE/DATA & WALL PHONE & WAP

OUTLET DETAIL & LABELING (TYPICAL)

NOT TO SCALE

120-1-3B

D1 D2

BLUE

JACK

BLUE

JACK

SPARE SPARE

PATCH PANEL

CLOSET NUMBER

RACK NUMBER

BUILDING NUMBER

DROP (SEAT) NUMBER

ROOM NUMBER

64445-101-014/015

120-1-3B

GRAY

JACK

V1

VDBB

NCTC

VDBB

NCTC

TELECOM

RM 1133

VDBB

NCCE

NC

NC

NURSE CALL SYSTEM -

SINGLE LINE DIAGRAM

NO SCALE

NCTC

NC

NC NC

NC NC

NCA

EL

NN

N N

DETAIL- TYPICAL

NCTC/NCCE

NO SCALE

VDBB

NCTC

NC

MANUFACTURERS

RECOMMENDED WIRING IN

2"C MINIMUM (TYP)

TERMINATE ALL CONDUITS WITH NYLON

INSULATED BUSHING. PROVIDE FIRE

STOP AS REQUIRED (TYP)

TELECOM

RM 1124

TELECOM

RM 1012

TELECOM

RM 1070

V1

GRAY

JACK

SPARE

NC

NC

CB

N

N

N Z

CB

64445-101-014/015

120-1-3B

D1 D2

YELLOW

JACK

YELLOW

JACK

SPARE SPARE

T

PI

T

PI

T

JBOX FOR MOTION

DETECTOR

JBOX FOR DURESS DEVICE

MOUNT 6" BELOW WORK SURFACE

(TYP)

JBOX FOR IDS

KEYPAD

ID

ID

ID

ID

ID

NOTE: SYSTEM IS CONDUIT/JUNCTION BOX/PULL

STRING ONLY. SYSTEM DEVICES AND WIRING

ARE BY OWNER. SEE FLOOR PLANS FOR EXACT

QUANTITY AND LOCATIONS OF EACH DEVICE.PHARMACY IDS SYSTEM-

SINGLE LINE DIAGRAM

NO SCALE

1/2"C Minimum

(TYP)

1/2"C TO PHARMACY DOOR(S)

GB GBJBOX FOR GLASS BREAK

SENSOR (TYP)

1/2"C Minimum (TYP)

IDID

1/2"C Minimum

(TYP)

ID

TO ADDITIONAL DEVICES

TO ADDITIONAL DEVICES

TO ADDITIONAL DEVICES

IDTC

TELECOM RM 1124

JBOX FOR WINDOW

CONTACT (TYP)

TT

IDID TO ADDITIONAL DEVICES

1/2"C Minimum

(TYP)

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P-

1 A

RE

A

M

ED

IC

AL

C

LIN

IC

R

EP

LA

CE

ME

NT

M

CK

EA

N

ST

, B

LD

G

CA

MP

P

EN

DL

ET

ON

, C

A

SA

N

DI

EG

O, C

AL

IF

OR

NI

A

NA

VA

L F

AC

IL

IT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D, S

OU

TH

W

ES

T

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

NE

C

OR

PS

B

AS

E

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1558864

DRAWFORM REVISION: 10 MARCH 2009

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22" IT IS A REDUCED SIZE DRAWING

4750 New Broad Street Orlando, Florida 32814 www.rlfae.com

LICENSE #AA C000564 #EB 0000629

FOR OFFICIAL USE ONLY

TBD

SAKARA / SANDROS

C:

\U se rs\ atk iso n_ m\

Do cu me nts

\B

LD

G- P0

-15

4-E _M att he w.

At kis on ss ain c.c om .rv t 2/2

3/2

8 1 0:2

3:4 5 A

M

12" = 1'-0"

TE

LE

CO

MM

UN

IC

AT

IO

NS

S

IN

GL

E

LIN

ES

EY603

MBA MBA RMH

18267541

02/28/18

R REG

IST

ER

ED

CO

MM

UNICATIONS DISTRIBUTION

DESIGNE

CR DD

Robert M. Huggins Reg. No. 191682R expires 12-31-19

R

M

NA T T H E W B A T K I S

O

A AL A B A M

L DI C E N S E

NO. 26286

CATCCATC

TELECOM

RM 1133

VDBB

CATC

PROVIDE CARD ACCESS

CONTROLLERS AND POWER

SUPPLIES AS REQUIRED FOR

DEVICES SHOWN ON FLOOR

PLANS (TYP).

CA

CA

CARD ACCESS SYSTEM -

SINGLE LINE DIAGRAM

NO SCALE

CAC

CAC

CAC

CAC

CAC

CAC

ROOM

CA

1-1"C WITH WIRING TO

COMM ROOM

PROVIDE (1) 4" SQUARE JUNCTION BOX WITH

BLACK COVER ABOVE ACCESSIBLE CEILING.

INSTALL CONCEALED CONDUITS AND WIRING

AS INDICATED. ALL CONDUITS SHALL BE 1/2"C

UON.

SINGLE GANG, NON-

METALLIC BOX WITH

PLASTER RING

MOUNTED FLUSH FOR

CARD READER. MOUNT

AT 44" AFF TO

CENTERLINE OF BOX.

CA CA

CA

CA

CEILING

POWER

TRANSFER

HINGE

SECURED SIDE

FLOOR

POWER

TRANSFER

HINGE

DOOR DETAIL 'A'

NO SCALE

1-1"C WITH WIRING TO

COMM ROOM

PROVIDE (1) 4" SQUARE JUNCTION BOX WITH

BLACK COVER ABOVE ACCESSIBLE CEILING.

INSTALL CONCEALED CONDUITS AND WIRING

AS INDICATED. ALL CONDUITS SHALL BE 1/2"C

UON.

SINGLE GANG, NON-

METALLIC BOX WITH

PLASTER RING

MOUNTED FLUSH FOR

CARD READER. MOUNT

AT 44" AFF TO

CENTERLINE OF BOX.

CA CA

CEILING

SECURED SIDE

FLOOR

DOOR DETAIL 'B'

NO SCALE

8" MINIMUM 8" MINIMUM

DOOR POSITION SWITCHDOOR POSITION SWITCH

CATC

CAC

CAC

CA

MANUFACTURERS

RECOMMENDED WIRING IN

2"C MINIMUM (TYP)

TERMINATE ALL CONDUITS WITH NYLON

INSULATED BUSHING. PROVIDE FIRE

STOP AS REQUIRED (TYP)

CCTCCCTCCCTC

CC

CC

VIDEO SURVEILLANCE SYSTEM -

SINGLE LINE DIAGRAM

NO SCALE

CC

CCTC

CC

TERMINATE ALL CONDUITS WITH NYLON

INSULATED BUSHING. PROVIDE FIRE

STOP AS REQUIRED (TYP)

SEE FLOOR PLANS FOR

EXACT QUANTITY AND

LOCATION (TYP).

PROVIDE DATA OUTLET

EACH LOCATION AS

INDICATED.

TELECOM

RM 1124

VDBB

TELECOM

RM 1012

VDBB

TELECOM

RM 1070

VDBB

TELECOM

RM 1133

VDBB

TELECOM

RM 1124

VDBB

TELECOM

RM 1012

VD…

This is the start of the file's text. The full file is on GovTribe.