B.08 7N23R0007 TDA Lamprey Amendment 4 Sheet M 001.pdf

PDF 426 KB Posted

Attached to
TDA Fish Accords Lamprey The Dalles
Solicitation number
W9127N23R0007
Issued by

About this file

This document contains mechanical plans and general notes for a lamprey fish passage flume project at The Dalles Dam. The solicitation was issued on April 28, 2023 as solicitation number W9127N23R0007 by the Department of the Army Corps of Engineers Engineering District Portland. The plans call for fabricating flume components from 3/16 inch 5052-H34 aluminum sheet per ASTM B209. All components must be cold formed with minimum bend radii of 9/16 inch and cut without flames. Welds must be water tight and build up where needed to ensure smooth transitions. Supports may use stainless steel shims and must be coated with zinc molybdate prior to installation. The contractor must install flumes leak free with smooth surfaces and no snags.

View the file

Other files

File Type Posted
B.08 7N23R0007 TDA Lamprey Amendment 5.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 4.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 4 Approximate 250 MCM ground conductor routing.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 4 Sheet MF 101.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 4 Specification 35 79 13.04 25.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 4 250 MCM Ground Conductor.jpg JPG image
B.08 7N23R0007 TDA Lamprey Amendment 3 Sheet SL202.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 3 Specification 22 00 00.00 25.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 3.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 3 Specification 35 79 13.04 25.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 3 Specification 05 50 15.00 25.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 3 Sheet SL201.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 2 Mechanical Plans.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 2.pdf PDF
I.01 7N23R0007 TDA Lamprey Site Visit Attendance Sheet.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 2 Sheet G 001.pdf PDF
B.08 7N23R0007 TDA Lamprey Amendment 1.pdf PDF
B.08 7N23R0007 TDA Lamprey Attachment A Offeror Experience Form.pdf PDF
B.08 7N23R0007 TDA Lamprey Attachment B Past Performance Questionnaire.pdf PDF
B.08 7N23R0007 TDA Lamprey Reference Drawings.pdf PDF
B.08 7N23R0007 TDA Lamprey Plans.pdf PDF
B.08 7N23R0007 TDA Lamprey Solicitation and Specifications.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

1 2 3 4 5

A

B

C

D

54321

ANGULAR

GENERAL

LINEAR FRACTIONAL

0.002"

0 DECIMAL PLACES

1 DECIMAL PLACE

LINEAR DECIMAL

0.010"

0.030"

TOLERANCES UNLESS OTHERWISE SPECIFIED

1 DECIMAL PLACE

0.5 0.1

2 DECIMAL PLACES

3 DECIMAL PLACES

SAWING, FLAME CUTTING,

SHEARING, AND BREAKING

STRUCTURAL SHAPES AND

WELDING

D E

S I G

N E

D

B

Y

D A

T E

D W

N

B

Y

C K

D

B

Y

S O

L I C

I T

A T

I O

N

N

O

C O

N T

R A

C T

N

O

S U

B M

I T

T E

D

B

Y

P L

S

A

L E

P

L O

T

D

A T

E

S I Z

E

F I L

E

N

A M

E

US Army Corps of Engineers

PORTLAND DISTRICT

SHEET

IDENTIFICATION

M-001

T H

E

D

A L

L E

S

L O

K

D

M

F Y

F

I S

H

A

C C

O R

L

M

P R

E Y

G

N E

R A

L

M

E C

H A

N I C

A L

N

O T

N I E

L

P

E N

N

G

E C

D D

P

G

E N

C M

G W

W

N

R

D A

N I E

L

M

J E

N S

E N

P

E

A N

S I

D

P O

R T

L A

I S

T R

I C

T

U S

A

R M

Y

C

O R

P

F

E

N G

I N

E E

R S

P O

R T

L A

N D

O

R E

G O

N

D D

F

M e c h a n i c a l

P l a n s i d w M

A R

K D

E S

C R

I P

T I O

N A

P P

R

D A

T

LEGEND:

BOLD LINES REPRESENT NEW ITEMS.

GREY LINES REPRESENT EXISTING ITEMS

BEND LINES

MECHANICAL GENERAL NOTES:

1. INFORMATION, TOLERANCES, AND NOTES ON THIS SHEET APPLY TO ALL MECH. DRAWINGS, UNLESS NOTED OTHERWISE.

2. DIMENSIONS SHOWN ARE BASED ON SPECIFIED EQUIPMENT. ADJUSTMENTS MAY BE REQUIRED DEPENDING ON SPECIFIC

EQUIPMENT APPROVED FOR INSTALLATION.

3. ALL LINEAR UNITS ARE FEET AND INCHES OR INCHES AND ALL ANGULAR UNITS ARE DEGREES, UNLESS SHOWN OTHERWISE.

4. WELDING OF STEEL IS TO BE PERFORMED IN ACCORDANCE WITH AWS D1.1.

5. WELDING OF ALUMINUM IS TO BE PERFORMED IN ACCORDANCE WITH AWS D1.2. WELD SIZES WILL BE THE MINIMUM SIZE

REQUIRED BY AWS D1.2 FOR THE TYPE OF WELD SHOWN UNLESS SHOWN OTHERWISE. REMOVE ALL BACKING BARS AND

STRIPS.

6. PROVIDE MECHANICAL FASTENERS PER ASTM F593C OR STRONGER WITH MATCHING NYLOC NUTS AND INSULATING

WASHERS. INSTALL WITH A MARINE GRADE ANTI-GALLING COMPOUND PER MIL-PRF-907E. INCLUDE NYLON WASHERS SIZED

FOR REQUIRED GASKET PRESSURE PRE-LOAD. SUBMIT ANY CALCULATIONS TO THE CONTRACTING OFFICER FOR APPROVAL.

16 FASTENERS REQUIRED PER FLUME FLANGE CONNECTION. 2 FASTENERS REQUIRED PER FLUME SUPPORT. 2 FASTENERS

REQUIRED PER RAMP SUPPORT.

7. PROVIDE EPDM GASKETS PER ASTM D1056-2A FOR ALL FLANGED PIPE CONNECTIONS. GASKETS SHOULD BE SIZED FOR 30%

COMPRESSION.

8. BREAK CORNERS AND EDGES.

9. ALL FISH CONTACTING SURFACES MUST BE SMOOTH TO THE TOUCH WITH NO BURRS OR SNAGS. FINAL SURFACING

SUBJECT TO USACE BIOLOGIST APPROVAL.

10. ALL FLUME COMPONENTS ARE FABRICATED FROM 3/16" 5052-H34 ALUMINUM SHEET PER ASTM B209 UNLESS SPECIFIED

OTHERWISE.

11. ALL LAMPREY FLUME COMPONENTS ARE TO BE COLD FORMED WITH BEND RADII NO LESS THAN 9/16" UNLESS SPECIFIED

OTHERWISE. COMPONENTS MUST HAVE CLEAN CUTS AND MAY NOT BE FLAME CUT.

12. WELD ALL LAMPREY FLUME COMPONENTS WATER TIGHT. BUILD UP WELDS AND GRIND TO MATCH BEND RADII WHERE

NECESSARY TO ENSURE CONTINUOUS TRANSITION BETWEEN HORIZONTAL AND VERTICAL SURFACES.

13. CONTRACTOR MUST INSTALL FLUMES LEAK FREE. FLUME TRANSITIONS MUST NOT PRESENT AN INTERNAL RAISED EDGE ON THE

UPSTREAM SIDE OF THE FLANGE CONNECTION. PROVIDE GASKETS FOR ALL FLANGED FLUME CONNECTIONS. TEMPLATE

FLANGE FOR GASKETS. GASKET MATERIAL MUST BE AN OUTDOOR RATED ETHYLENE PROPYLENE DIENE MONOMER WITH A

DUROMETER OF 60A, WITH A MINIMUM TENSILE STRENGTH OF 1000 PSI, HAVE A RATED TEMPERATURE RANGE FROM -40F TO

225F, AND HAVE A NOMINAL THICKNESS NO GREATER THAN 1/8".

14. TORQUE FLUME FLANGE FASTENERS EQUALLY ACROSS THE CENTERLINE OF THE FLUME. TORQUE SHOULD BE APPLIED IN

THREE EQUAL STAGES SO FLANGES DO NOT BECOME DISTORTED. FINAL TORQUE SHOULD BE 20 FT-LB.

15. CONTRACTOR DESIGNED SUPPORTS MAY BE INSTALLED USING STAINLESS STEEL SHIMS TO LEVEL OR ACCOUNT FOR SLOPE.

CONTRACTOR PROVIDED SUPPORTS MUST BE PROVIDED TO ALLOW THE SHIM TO BE CAPTURED OR CLAMPED DURING

INSTALLATION.

16. THE SURFACE OF THE RAMP OR FLUME SUPPORT THAT WILL BE INSTALLED AGAINST THE CONCRETE SURFACE MUST BE COATED

WITH ZINC MOLYBENDATE IN ACCORDANCE WITH FED SPEC TT-P-645B PRIOR TO INSTALLATION. THE COATING MUST BE FULLY

CURED BEFORE PIECES ARE SHIPPED TO THE DALLES DAM FOR INSTALLATION.

17. SUPPORT ANCHORS MUST BE INSTALLED WITHOUT INTERFERING WITH EXISTING REBAR LOCATIONS. SURVEY FOR EXISTING

REBAR PRIOR TO INSTALLATION.

18. DIMENSIONS SHOWN IN PARENTHESIS ARE FOR REFERENCE ONLY.

19. HEMMED EDGES MAY BE OPEN OR TEARDROP HEMS. MINIMUM INTERNAL RADIUS OF HEM TO BE EQUAL TO MATERIAL

THICKNESS. MINIMUM HEM RETURN LENGTH TO BE 6 TIMES THE MATERIAL THICKNESS. HEMS MUST NOT PRESENT SHARP

EDGES.

R

E V

I S

P

R

M E

N D

M E g2ecddp9 Cloud

File details come from the government source that posted it. Updated .