E-201_Color.pdf
PDF 284 KB Posted
- Solicitation number
- W9127N-20-R-0016
About this file
This document includes engineering drawings and specifications for the replacement of two electrical panels at Bonneville Lock and Dam Powerhouse II in Oregon. The solicitation is seeking proposals to replace the original SU and CQ 480V panels, which are no longer being manufactured and are rated as being in marginal condition. The work will be performed by the U.S. Army Corps of Engineers Portland District for Bonneville Dam, which is located on the Columbia River approximately 40 miles east of Portland. Bonneville Dam includes two powerhouses, with Powerhouse II being the subject of this work to replace its aging secondary unit and control and quarter panels.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P O
R T
L A
N D
O R
E G
O N
P O
R T
L A
N D D
IS
T R
IC
T
U S A
R M
Y C
O R
P S O
F E
N G
IN
E E
R S
-1
-2
-1
-2
A N
S I F
S
W
T H A
V E
N U
E S
T E
P O
R T
L A
N D
O R
-1
H D
R E
N G
IN
E E
R
IN
G
IN
C
H D
R
H D
R
H D
R W
N
R
A S N
O T
E D
0 6" 1' 2'
SCALE:1 1/2"=1'
SUA FRONT ELEVATION
EL 5
WIREWAY (TYP)
HORIZONTIAL
WIREWAY (TYP)
HORIZONTIAL
WIREWAY (TYP)
VERTICAL
EL 15.0
EL 14.0
LINE 1 LINE 2 NO.
NAMEPLATE SCHEDULE
3P 50A
3P 50A
3P 30A
3P 15A
3P 15A
3P 30A
3P 50A
3P 50A
3P 15A
3P 15A
3P 100A
3P 70A
3P 15A
3P 45A
3P 50A
3P 20A
3P 70A
3P 30A
3P 15A
3P 40A
3P 20A
3P 50A
3P 30A
#2/0 #2/0
0 6" 1' 2'
SCALE:1 1/2"=1'
SUA SINGLE LINE DIAGRAM
UNIT F1 GOVERNOR
UNIT F2 GOVERNOR
UNIT F1
480V OUTLETS
UNIT F1 HIGH PRESSURE
LIGHTING TRANSFORMER
UNIT F1 COOLING
PASSENGER
POWER PANEL 2-CRA
UNIT F1 TURBINE BRG.
UNIT F1 HEAD COVER
UNIT F2 HEAD COVER
UNIT F2 TURBINE BRG.
UNIT F1 HEAD COVER
PASSENGER
SPACE
BUS 2
480V OUTLET
POWER PANEL 2-CRA
LIGHTING TRANSFORMER
UNIT F2 COOLING
UNIT F2 HIGH PRESSURE
480V OUTLETS
UNIT F1 GOVERNOR
UNIT F2 GOVERNOR
UNIT F2
OIL PUMP NO. 1
OIL PUMP NO. 1
HEATERS
BRG. OIL PUMP
TR4
WATER STRAINER
ELEVATOR NO. 1
VIA ATS NORMAL
OIL RETURN PUMP
PUMP NO. 1
PUMP NO. 2
OIL RETURN PUMP
PUMP NO. 2
ELEVATOR NO. 2
MAIN LUGS
VIA ATS ALTERNATE
TR5
WATER STRAINER
BRG. OIL PUMP
OIL PUMP NO. 2
OIL PUMP NO. 2
HEATERS
1A
1B
1C
1D
1E
2A1
2A2
2B1
2B2
2C1
2C2
2D
2E
2F
4A
4B
4C
4D1
4D2
4E
5A1
5A2
5B1
5B2
5C1
5C2
5D
5E
5F 2C1
2B1
2A1 2A2
2B2
2C2
4D24D1
5C25C1
5B1 5B2
5A25A11A
1B
1C
1D
1F
2D
2E
2F
4A
4B
4C
4E
4F
5D
5E
5F
BDP-5-6-1A8/6 - 480 VOLT CONTROL CENTERS - SUA
W57790056006 - ASSEMBLY DRAWING - MCC SUA
REFERENCE DRAWINGS:
E-630 - SUA CONTROL SCHEMATICS - INSTALL
E-602 - SUA ONE-LINE DIAGRAM - INSTALL
COMPANION DRAWINGS:
3A
3B
3C
3D
3E
3A
3B
3C
3D
3E
UNIT F2 HEAD COVER PUMP NO. 1
SPACE
SPACE
SPACE
SPACE
Q5
Q2
SPACE
Q1
ETM (TYP)
HORIZONTAL BUS RATED FOR 600A
HORIZONTAL BUS RATED FOR 600A
4F
NOTE 3
1E
BUS 1 MAIN LUGS 1F
SPACE
OIL RETURN PUMPUNIT F1
UNIT F2 OIL RETURN PUMP
3P 15A
3P 15A
SEE NOTE 2
SUA-q1-AQF2, 3/4"
SUA-c1-AF1, 1 1/4"
SUA-q1-AQF1, 3/4"
SUA-q1-HCF2, 1/2"
SUA-q1-HCF1, 1/2"
SUA-q1-HPF1, 1/2"
SUA-q1-QPF1, 1/2"
SUA-Q1-GHF1. 3/4"
SUA-q1-QPF2, 1/2"
SUA-q1-GHF2, 3/4"
SUA-q1-HPF2, 1/2"
SUA-q2-HCF2, 1/2"
SUA-q2-HCF1, 1/2"
SUA-c1-AF2, 1 1/4"
SUA-q2-AQF1, 3/4"
SUA-q2-AQF2, 3/4"
SUA-c1-TPF1, 1 1/4"
SUA-q3, 1" SUA-q4, 1"
SUA-c1-TPF2, 1 1/4"
SUA-q2-HCF1, 1/2"
3P 15A
3P 15A
1'-8"1'-8"1'-8"1'-8"1'-8"
8'-4"
THE FLOOR.
IN ITS HIGHEST POSITION, IS MORE THAN 6 FT 7 IN. ABOVE
THE OPERATING HANDLE OF THE CIRCUIT BREAKER, WHEN
CIRCUIT BREAKERS WHERE THE CENTER OF THE GRIP OF
CONTRACTOR TO PROVIDE HANDLE EXTENSIONS FOR 5.
ALL VERTICAL BUS SECTIONS TO BE RATED 600A.4.
LOCATED IN MCC.
GROUND INSERT AND NEW CONTINUOUS GROUND BUS
CU CONDUCTOR BETWEEN POWERHOUSE STATION
CONTRACTOR SHALL SUPPLY AND INSTALL NEW BARE #2/0 3.
EXISTING CONDUIT TO BE REUSED FOR NEW CABLE.2.
BDP-1-6-1C1_1.
AT ELEVATION 5.67. REFERENCE SECTION A-A ON DRAWING
1", SQ3-Q2-SUA 2" ENTER SUA THROUGH WALL BEHIND SUA
1", SUA-Q1-GWF2 1/2", SUA-S1 1 1/4", SUA-Q1-TR5 3/4" SUA-Q2
SQ3-Q1-SUA 2", SUA-Q1-GWF1 1/2", SUA-Q1-TR4 3/4", SUA-Q1 1.
NOTES:
1'-0"
EXISTING CABLE TRAY
BREAKER CONDUCTORS.
BOX FOR SUA MAIN CIRCUIT
DEPTH TO BE USED AS PULL
PROVIDE TOP HAT WITH 18"
SQ3-q2.2-SUA, 2" SQ3-q2.1-SUA, 2" SQ3-q1.2-SUA, 2" SQ3-q1.1-SUA, 2"
SEE E217
BREAKERS
CIRCUIT
TO SUA MAIN
E-201
IN
S
T A
L L
S U
A E
L E
V A
T
IO
N V
IE
W
E -X .X
X X
E -2
X X
X .d g n
E
PORTLAND DISTRICT
of Engineers
US Army Corps
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
1 2 3 4 5
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
C O
L U
M B
IA
R
IV
E R
S E
C O
N D P
O W
E R
H O
U S
E
S U A
N D C
Q R
E P
L A
C E
M E
N T
File details come from the government source that posted it. Updated .