This document is an amendment to a solicitation for an aircraft maintenance hangar at Soto Cano Air Base in Honduras. The amendment revises specifications, drawings, and contract clauses. It increases performance bond requirements from 15% to 100% of the original contract price and increases payment bond requirements from 100% to 100% of the original contract price. It also requires contractors to comply with any COVID-19 policies implemented in the local area and describe processes for implementing protective measures on project sites. Revised specifications include additional paragraphs on COVID-19 policies and requirements to submit an exposure control plan and blood-borne pathogens plan. Revised drawings and contract hardware sets are also provided.

View the file

Other files

File Type Posted
AM07.pdf PDF
AM06.pdf PDF
AM06 DRAWINGS.pdf PDF
W9127820R0012 - Virtual Site Visit Presentation.PDF PDF
AM05 DRAWINGS.pdf PDF
AM05.pdf PDF
AM04.pdf PDF
AM03.pdf PDF
AM03 DRAWINGS.pdf PDF
AM02 DRAWINGS.pdf PDF
AM02.pdf PDF
AM01 DRAWINGS.pdf PDF
VOL5.PDF PDF
VOL6.PDF PDF
VOL4.PDF PDF
EM 385-1-1.pdf PDF
VOL 1 RTA DRAWINGS.pdf PDF
VOL 2 RTA DRAWINGS.pdf PDF
VOL2.PDF PDF
VOL1.PDF PDF
VOL3.PDF PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

1 3

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE 5. PROJECT NO. (If applicable)

W9127820R0012-0001 4 JUNE 2020 M017EU45

6. ISSUED BY CODE 7. ADMINISTERED BY(If other than item 6)

CODE

Corps of Engineers 109 St. Joseph St.

Mobile, AL 36602

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION

NO.

W9127820R0012

9B. DATED (SEE ITEM 11)

6 MAY 2020

10A. MODIFICATION OF

CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers is extended, is not extended. Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (if required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO AUTHORITY OF FAR 43.103(b)

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible)

The subject solicitation for: FY20 AIRCRAFT MAINTENANCE FACILITY

SOTO CANO AIR BASE, HONDURAS

Is modified in the following: REFER TO THE ENCLOSED REVISED SPECIFICATIONS FOR AMENDMENT NO. 0001

Except as provided herein, all terms and conditions of the document reference in item 9A or 10A, as Heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICE (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

BY

(Signature of contracting officer)

16C. DATE SIGNED

NSN 7540-01-152-8070 30-105 STANDARD FORM 30 (REV. 10-83)

PREVIOUS EDITION UNUSABLE Prescribed by GSA

FY20 AIRCRAFT MAINTENANCE FACILITY W9127820R0012

SOTO CANO AIR BASE, HONDURAS M017EU45

SF 30 Page 2 W9127820R0012-0001

PART I - REVISIONS MADE BY ADDED AND/OR REPLACEMENT PARAGRAPHS/PAGES/SECTIONS

The items listed below are to be replaced by the corresponding added and/or revised paragraphs/pages or sections. Added and/or revised paragraphs/pages or sections are indicated by a note in bottom right hand corner of each paragraph or page. Added sections are hereby made a part of the contract and are to be inserted in the specification in the proper numerical/alphabetical sequence.

Within the specifications, deletions from the specifications are indicated by strikethrough, e.g.: deletions are marked with strikethrough and additions to the specifications including revisions/substitutions are indicated in bold, italic and underlined, e.g.: additions are indicated thus.

Corresponding Added or Revised Paragraph SECTION Page, and/or Section

00 70 00 Revised Clause 52.228-15 as indicated herein.

01 00 00 Added Paragraph 1.34 as indicated herein.

01 35 26 Added Paragraph 1.17 as indicated herein.

08 71 00 Revised Paragraph 3.6 as indicated herein.

PART II - NOTE: Revised and replacement drawings are listed below. These revised and replacement drawings are to be inserted into the folio in the proper numerical sequence. Drawings that have been revised or replaced by this amendment shall be deleted from the folio. All drawings listed below are revised unless indicated otherwise.

SHT

REF. TITLE OF DRAWINGS

COVER SHEET

S-110 FIRST FLOOR SLAB PLAN AREA B

S-112 FIRST FLOOR SLAB PLAN AREA D

S-114 FIRST FLOOR SLAB PLAN AREA F

S-119 LOW ROOF FRAMING PLAN AREA A AND D

S-124 INTERMEDIATE ROOF FRAMING PLAN AREA C AND F

S-129 HANGAR ROOF FRAMING PLAN COMPOSITE

S-130 HANGAR ROOF FRAMING PLAN AREA D

S-131 HANGAR ROOF FRAMING PLAN AREA E

S-132 HANGAR ROOF FRAMING PLAN AREA F

S-207 FRAMING ELEVATIONS

S-210 GIRT FRAMING ELEVATIONS

S-211 GIRT FRAMING ELEVATIONS

S-309 ROOF FRAMING SECTION AND DETAILS

S-311 ROOF FRAMING SECTION AND DETAILS

S-312 GIRT FRAMING SECTIONS

S-504 TYPICAL FRAMING DETAILS

SF 30 Page 3 W9127820R0012-0001

S-512 TYPICAL DOOR SUPPORT FRAMING DETAILS

S-513 TYPICAL BOTTOM CHORD FRAMING DETAILS

S-514 TYPICAL ROOF DECK AND JOIST DETAILS

A-104 FIRST FLOOR ANNOTATIVE PLAN

A-319 ENLARGED SECTIONS

A-405 ENLARGED MILLWORK PLANS & ELEVATIONS

A-406 ENLARGED MILLWORK PLANS & ELEVATIONS

A-502 STAIR SECTIONS - L101

A-508 ELEVATOR SECTION

A-511 ROOF DETAILS

A-513 EXTERIOR WALL & ROOF DETAILS

A-601 DOOR SCHEDULE

A-602 DOOR SCHEDULE SECOND FLOOR DOOR SCHEDULE

A-608 WINDOW SCHEDULE AND ELEVATIONS

A-611 LOUVER & WINDOW DETAILS

I-002 FURNITURE FIXTURES & EQUIPMENT LEGEND

I-121 FIRST FLOOR FFE COMPOSITE PLAN

I-122 FIRST FLOOR FFE PLAN

I-123 FIRST FLOOR FFE PLAN

I-124 FIRST FLOOR FFE PLAN

I-125 SECOND FLOOR FFE PLAN

I-126 SECOND FLOOR FFE PLAN

I-127 SECOND FLOOR FFE PLAN

I-128 SECOND FLOOR BRIEFING ROOM FFE ENLARGED PLANS

Encl as stated Replaced pages of the specifications as indicated in Part I.

41 Revised drawing as indicated in Part I.

00 70 00 Revised by Amendment No. W9127820R0012-0001

00 70 00

52.228‐15 ‐ Performance and Payment Bonds‐‐Construction

(a) Definitions. As used in this clause‐‐

Original contract price means the award price of the contract; or, for requirements contracts, the price payable for the estimated total quantity; or, for indefinite‐quantity contracts, the price payable for the specified minimum quantity. Original contract price does not include the price of any options, except those options exercised at the time of contract award.

(b) Amount of required bonds. Unless the resulting contract price is $150,000 or less, the successful offeror shall furnish performance and payment bonds to the Contracting Officer as follows:

(1) Performance bonds (Standard Form 25). The penal amount of performance bonds at the time of contract award shall be 100 15 percent of the original contract price.

(2) NOT USED. Payment Bonds (Standard Form 25‐A). The penal amount of payment bonds at the time of contract award shall be 100 percent of the original contract price.

(3) Additional bond protection. (i) The Government may require additional performance and payment bond protection if the contract price is increased. The increase in protection generally will equal 100 percent of the increase in contract price.

(ii) The Government may secure the additional protection by directing the Contractor to increase the penal amount of the existing bond or to obtain an additional bond.

(c) Furnishing executed bonds. The Contractor shall furnish all executed bonds, including any necessary reinsurance agreements, to the Contracting Officer, within the time period specified in the Bid Guarantee provision of the solicitation, or otherwise specified by the Contracting Officer, but in any event, before starting work.

(d) Surety or other security for bonds. The bonds shall be in the form of firm commitment, supported by corporate sureties whose names appear on the list contained in Treasury Department Circular 570, individual sureties, or by other acceptable security such as postal money order, certified check, cashier's check, irrevocable letter of credit, or, in accordance with Treasury Department regulations, certain bonds or notes of the United States. Treasury Circular 570 is published in the Federal Register or may be obtained from the U.S. Department of the Treasury, Financial Management Service, Surety Bond Branch, 3700 East West Highway, Room 6F01, Hyattsville, MD 20782. Or via the internet at http://www.fms.treas.gov/c570/.

(e) Notice of subcontractor waiver of protection (40 U.S.C. 3133(c)). Any waiver of the right to sue on the payment bond is void unless it is in writing, signed by the person whose right is waived, and executed after such person has first furnished labor or material for use in the performance of the contract.

(Note: The remainder of the section is unchanged by this amendment.)

01 00 00

01 00 00

1.34 COVID-19 POLICY

The contractor is to comply with any local/host nation policies and regulations implemented in response to COVID-19. Additionally, the contractor shall describe their processes for implementing effective COVID-19 protective measures while working on USACE project sites.

These measures shall be addressed in the Accident Prevention Plan (APP) required by Section 01 35 26, via a Site Sanitation Plan, Health Hazard Control Plan (HAZCOM), or a specific memo/policy that clearly defines how the contractor is going to implement these steps.

01 35 26

01 35 26

1.17 COVID-19 POLICY

In accordance with Appendix A of the EM 385-1-1, the contractor is required to submit an Exposure Control Plan (ECP) and a Blood-Borne Pathogens Plan (BPP).

08 71 00

3.6 HARDWARE SETS

Provide hardware for aluminum doors under this section. Deliver Hardware templates and hardware, except field-applied hardware to the aluminum door and frame manufacturer for use in fabricating the doors and frames.

SET ITEM DESCRIPTION FINISH

HW-1 PAIR ALUM. ENTRANCE DOORS: L101

6 EA. PIVOTS BY ALUM DOOR MANUFACTURER 630

2 EA. CLOSERS C02081 PT1,PT4C,PT4D,PT4F 626

2 EA. PUSH PAD, EXIT DEVICES, TYPE 6, FUNCTION 10 626

2 EA. DOOR PULLS by door mfr. 628

2 EA DUST PROOF STRIKE L04011

2 EA SWEEP ROY416 718

1 EA. THRESHOLD 7" equal to Pemko 1718 718

4 EA. SILENCERS GREY

1 SET WEATHERSTRIP

1 SET MEETING STILES ROY824

HW-2 SINGLE DOOR EXITS EXTERIOR:112D 114A 104A 115B 117B 126B

1 1/2 PAIRS BUTTS, A5111 NRP 630

1 EA. LOCKSET, FUNCTION F04, ENTRY DOOR LOCK 626

1 EA. CLOSER C02021 689

1 EA, OVERHEAD STOP C01511 626

1 EA. KICKPLATE, J102 630

1 EA. THRESHOLD 5 1/2" Equal to Pemko 158 718

3 EA. SILENCERS L03011 GREY

1 EA RAIN DRIP ROY936(FOR DOORS WITHOUT OVERHEAD COVER)

1 EA SWEEP ROY536 718

1 SET WEATHERSTRIPPING

HW-3 SINGLE DOOR EXTERIOR CORRIDOR-EXIT: C101A C104B C102A 101A 102B 102C

102D 109B S101A

1 1/2 PAIRS BUTTS, A5111 NRP 630

1 EA. EXIT DEVICES, TYPE 1, (PUSH PAD), FUNCTION 10 689

1 EA. CLOSER C02021 689

1 EA. KICKPLATE J102 630

1 EA. THRESHOLD 5 1/2" Equal to Pemko 158 718

1 EA RAIN DRIP ROY936 (FOR DOORS WITH OUT OVERHEAD COVER)

1 EA SWEEP ROY536 718

3 EA. SILENCERS L03011 GREY

HW-4 SINGLE DOOR EXTERIOR UTILITY: E101 E102 108 M103 M105 S301

1 1/2 PAIRS BUTTS, A5111 NRP 630

1 EA. LOCKSET, FUNCTION F07, STORAGE DOOR LOCK 626

1 EA, OVERHEAD STOP C01511 626

1 EA. THRESHOLD 5 1/2" Equal to Pemko 158 718

1 EA RAIN DRIP ROY936 718

1 SET WEATHERSTRIPPING

HW-5 PAIR EXTERIOR EQUIPMENT ROOM DOORS: E103 M101 M102 M106 110B 119B

3 PAIR BUTTS, 5"X5" A5111 NRP 630

1 EA. LOCKSET, FUNCTION 07, STORAGE LOCK 626

1 SET FLUSH BOLTS L04081 626

2 EA. HOLDER STOP C03511 689

1 EA ASTRAGAL 630

1 EA COORDINATOR TYPE 21 630

1 EA DUST PROOF STRIKE L04011 630

2 EA RAIN DRIP ROY936 718

1SET WEATHERSTRIPPING GREY

1 EA. THRESHOLD 5 1/2" Equal to Pemko 158 719

HW-6 PAIR HANGAR BAY DOORS FR: 110A 113 117A

3 PAIR BUTTS, 5"x5" A8111 626

1 EA. LOCKSET, FUNCTION 07, STORAGE LOCK 626

1 SET FLUSH BOLTS L04081 626

2 EA. CLOSER C02021 689

1 EA ASTRAGAL 630

1 EA COORDINATOR TYPE 21 630

1 EA DUST PROOF STRIKE L04011 630

4 EA. GASKET R0Y184 GREY

HW-7 UPWARD ACTING COILING DOORS: 102A

1 EA. CYLINDER LOCK BY DOOR MANUFACTURER SEE SECTION 08 33 23

1 SET WEATHER SEAL BY DOOR MANUFACTURER EXTERIOR DOORS ONLY

HW-8 UPWARD ACTING COILING DOORS FR: 112B 114C

1 EA. CYLINDER LOCK BY DOOR MANUFACTURER SEE SECTION 08 33 23

1 EA. FUSIBLE LINK CLOSING ACTIVATION

1 SET SMOKE SEAL BY DOOR MANUFACTURER

HW-9 INTERIOR SINGLE DOORS: 123 125 127 130 133 134 135 203 204 205 207 217

218 220 221 222 225 226 227 228 229 230 231 232 233 234 236 237 238 239 240 242 243 244 245 246 247 248 250 251

1 1/2 PAIR BUTTS, A8112 652

1 EA. LOCKSET, FUNCTION F82 OFFICE LOCK 626

1 EA. WALL STOP, L02151 (Where door is adjacent to wall) 626 1 EA. OVERHEAD STOP, CO2541 (For other conditions) 689

3 EA. SILENCERS, L03011 GREY

HW-10 INTERIOR SINGLE DOORS: 213,

1 1/2 PAIR BUTTS, A8112 652

1 EA. LOCKSET, FUNCTION F04 ENTRY LOCK 626

1 EA. SECURITY X-10 LOCK

1 EA. WALL STOP, L02151 (Where door is adjacent to wall) 626

3 EA. SILENCERS, L03011 GREY

HW-11 INTERIOR SINGLE FR DOORS: 112C 114B 115A 117A 118 122 126A 131 132

1-1/2 PAIR BUTTS, A8112 652

1 EA. LOCKSET, FUNCTION F04 ENTRY LOCK 626

1 EA. CLOSER C02011

1 EA. OVERHEAD STOP C01541 689

2 EA. KICKPLATES J102 630

3 EA. SILENCERS L03011 GREY

HW-12 INTERIOR SINGLE FR DOORS: S101B

1 1/2 PAIR BUTTS, A8112 652

1 EA. LOCKSET, FUNCTION F75 PASSAGE LOCK 626

1 EA. CLOSER C02011

1 EA. OVERHEAD STOP C01541

2 EA. KICKPLATES J102 630

3 EA. SILENCERS L03011 GREY

HW-13 INTERIOR SINGLE COMSEC DOORS: 116

1 1/2 PAIR BUTTS(nonremoval hinge pins) A8112 652

1 EA. LOCKSET, FUNCTION F07 STORE ROOM LOCK 626

1 EA. OVERHEAD STOP C02511 626

2 EA. KICKPLATES J102 630

3 EA. SILENCERS L03011 GREY

HW-14 INTERIOR SINGLE DOORS: 104B 103 106 107 109A 115C 119A 124

1 1/2 PAIR BUTTS A8112 652

1 EA. LOCKSET, FUNCTION F04 ENTRY LOCK 626

1 EA. WALL STOP, C02251 (Where door is adjacent to wall) 626 1 EA. OVERHEAD STOP, CO2541 (For other conditions) 626

1 EA. KICKPLATE J102 630

3 EA. SILENCERS L03011 GREY

HW-15 INTERIOR SINGLE SINGLE FR EXIT DOOR: C101B C102B C103A C103B C104A

C105A 129B C200 S201

1 1/2 PAIRS BUTTS, A8111 626

1 EA. EXIT DEVICE TYPE 1 FUNCTION 14 PASSAGE 626

1 EA. CLOSER C02011 689

1 EA. KICK PLATE J102 630

1 EA. WALL STOP, L02101

3 EA. SILENCERS L03011 GREY

HW-16 INTERIOR SINGLE WOOD DOOR RESTROOM DOOR: 120 121 212 216 215

1 1/2 PAIRS BUTTS, A5111 630

1 EA. CLOSER C02021 689

1 EA. PUSH PLATE J302 626

1 EA. PULL PLATE J303 626

1 EA. KICKPLATE, J102 630

1 EA. MOP PLATE, J103 630

1 EA. WALL STOP L02101 626

3 EA. SILENCERS L03011 GREY

HW-17 EXTERIOR DOUBLE EXIT DOOR: C105B

3 EA. PAIR BUTTS, 5"X5" A5111 652

2 EA. EXIT DEVICE TYPE 2 FUNCTION 10 630

2 EA. CLOSER/HOLD C02061 689

2 EA DUST PROOF STRIKE L04011 630

2 EA. KICK PLATES J102 630

1 EA. THRESHOLD 6" equal to Pemko 256 718

4 EA. SILENCERS GREY

1 SET WEATHERSTRIP meetin g stiles 630

1 EA RAIN DRIP ROY936 718

HW-18 INTERIOR SINGLE DOORS: E104 E105 M104 128 E200 E201 208 211 249

1 1/2 PAIR BUTTS, A8112 652

1 EA. LOCKSET, FUNCTION F86 STORE ROOM LOCK 626

3 EA. SILENCERS L03011 GREY

1 EA. WALL STOP L02251 626

1 EA. KICK PLATES J102 630

HW-18A INTERIOR SINGLE DOORS: 118 208

1 1/2 PAIR BUTTS, A8112 652

1 EA. LOCKSET, FUNCTION F86 STORE ROOM LOCK 626

3 EA. SILENCERS L03011 GREY

1 EA. WALL STOP L02251 626

1 EA. KICK PLATES J102 630

1 EA. HEAD/JAMB SEALED GASKET R0Y165

1 EA. AUTOMATIC DOOR BOTTOM R0Y336

HW-19 INTERIOR SINGLE DOORS: 210B 210A 214A 214B 224

1 1/2 PAIR BUTTS, A8112 652

1 EA. LOCKSET, FUNCTION F84 CLASS ROOM LOCK 626

1 EA. OVERHEAD STOP C01541 689

1 EA. WALL STOP L02251 (AT DOOR SWING ADJACENT TO WALLS)

3 EA. SILENCERS L03011 GREY

2 EA. KICK PLATES J102 630

HW-20 PAIR DOUBLE METAL DOOR: M201 M202 M203 M204

3 EA. PAIR BUTTS, 5"X5" A8112 652

1 EA. LOCKSET, FUNCTION F86, STORE ROOM LOCK 626

1 SET LEVER EXTENSION FLUSH BOLTS L04081 630

2 EA. STOP/HOLDOPEN C02511 689

1 EA. COORDINATOR TYPE 21 626

1 EA DUST PROOF STRIKE L04011

4 EA. KICK PLATES J102 630

HW-21 COUNTER SHUTTER: CD1

1 EA. CYLINDER LOCK 626

HW-22 HANGAR EMERGENCY DOORS: H101 H102

1-1/2 PAIR BUTTS K81011F SPRING HINGE 652

1 EA. LATCH SET EXIT PASSAGE WITH RECESSED RELEASE HANDLE 626

PROVIDE EXTERIOR SIDE LATCH RELEASE

HW-23 SINGLE DOORS: 111

1-1/2 PAIR BUTTS A8112 652

1 EA. LOCKSET, FUNCTION F86, STORE ROOM LOCK 626

1 EA. CLOSER C03021 689

1 EA. KICK PLATES J102 630

3 EA. SILENCERS L03011 GREY

HW-24 CLASS V VAULT DOOR W/ DAY GATE: V105 117

ALL HARDWARE BY DOOR MANUFACTURER. SEE SECTION 08 34 59.

HW-25 METAL WIRE CAGE DOORS:

1 1/2 PAIR BUTTS 5"X5" A8133 652

1 EA. RIM LOCK E06211 652

HW-26 ROOF ACCESS HATCH PADLOCK 626

HW-27 CHAINLINK GATES 5 BUTTON MECHANICAL LOCK 652

(SIMPLEX L1000 KABA)

HW-28 COM ROOM 219

1 EA 5 BUTTON MECHANICAL LOCK 652

(SIMPLEX 5021BWL KABA)

1 1/2 PAIR BUTTS, A8112 652

1 EA. WALL STOP, L02151 626

3 EA. SILENCERS, L03011 GREY

HW-29 INTERIOR SINGLE DOORS: 211

1 1/2 PAIR BUTTS 652

1 EA LOCKSET FUNCTION F05, CLASSROOM LOCK 652

1 EA CLOSER C02011 689

1 EA KICKPLATE J102 630

1 EA WALLSTOP L02101 626

3 EA SILENCERS, L03011 GREY