Dwgs V-II - ATC4 Large Business -RE- RTA.pdf
PDF 35 MB Posted
- Solicitation number
- W9126G-11-R-0216
About this file
Solicitation Dwgs V-II - ATC4 Large Business -RE- RTA
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2nd_Site_Visit_Attendee_List--03_2012.pdf | ||
| 1st_Site_Visit_Attendee_List--01_2012.pdf | ||
| am_6.pdf | ||
| am_5.pdf | ||
| am_4.pdf | ||
| am_3.zip | ZIP file | |
| am_2.pdf | ||
| g11r0216_am_1.zip | ZIP file | |
| Dwgs V-III - Pedestrian Bridge - RE-RTA.pdf | ||
| g11r0216.zip | ZIP file | |
| Dwgs V-I - ATC4 Large Business - RE-RTA.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1 2 3 4 5
E
D
C
B
A
LACKLAND AIR FORCE BASE
SAN ANTONIO, TEXAS
PROJECT NUMBER MPLS 083737R4
CONTRACT NO.
AIRMEN TRAINING COMPLEX - EAST CAMPUS
AIRMEN TRAINING COMPLEX 4 (ATC4)
VOLUME II
SOLICITATION NO. W9126G-11-R-0216
DATED: SEPTEMBER 2011
LACKLAND DRAWING NO. LA 11-0009
VERIFICATION: VERIFY ALL DIMENSIONS, ELEVATIONS, SITE CONDITIONS, AND
EQUIPMENT BEFORE STARTING WORK OR PROCURING PRODUCTS OR EQUIPMENT.
CONFLICTS: IF CONFLICTS OCCUR, THE MORE RESTRICTIVE (INCLUDING
SPECIFICATIONS) SHALL TAKE PRECEDENCE.
CODES: ALL MATERIALS AND WORK SHALL CONFORM TO THE REQUIREMENTS OF THE
IBC 2009, UFC'S, NFPA CODES AND OTHER STANDARDS INDICATED OR SPECIFIED.
SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY
PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK
SHOWN ON DRAWINGS.
PENETRATIONS: PIPES, DUCTS, SLEEVES, CONDUIT, CHASES, ETC.: REFER TO
DRAWINGS AND SPECIFICATIONS FOR REQUIREMENTS. PROVIDE SMOKE SEALING AND
FIRE STOPPING AT ALL FLOORS, SMOKE PARTITIONS AND FIRE RATED WALLS.
EXCAVATIONS: LOCATE AND PROTECT UNDERGROUND OR CONCEALED UTILITIES
INCLUDING CONDUIT, DUCT BANK AND PIPING WHERE NEW WORK IS BEING PERFORMED.
EQUIPMENT LOADS: MATERIAL LOADS SHALL NOT EXCEED THE ALLOWABLE LOADING
FOR THE SUPPORTING MEMBERS AND THEIR CONNECTIONS.
DRAWINGS: REFER TO ALL DRAWINGS FOR ITEMS WHICH REQUIRE COORDINATION AND
SPECIAL PROVISIONS FOR COMPLETE AND OPERATIONAL SYSTEMS.
CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT DRAWINGS AND
SPECIFICATIONS REPRESENT THE FINISHED BUILDING AND DO NOT INDICATE METHODS
OR PROCEDURES. DRAWINGS AND SPECIFICATIONS DO NOT INDICATE SEQUENCE OF
CONSTRUCTION, EXCEPT FOR PHASING PLANS.
DEVIATION: ANY DEVIATION FROM THE APPROVED CONSTRUCTION DOCUMENTS SHALL
ONLY BE MADE AFTER WRITTEN APPROVAL BY THE CONTRACTING OFFICER.
COORDINATION: NON-DIMENSIONED DRAWINGS INDICATE ONLY THE APPROXIMATE
LOCATION OF ITEMS. THE FINAL POSITIONING OF THESE ITEMS IS DEPENDENT UPON
THE ACTUAL ITEMS PROVIDED BY CONTRACTOR IN ACCORDANCE WITH ALL RELEVANT
BUILDING CODES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING
WORK BETWEEN SUBCONTRACTORS AND CRAFTS AND PROVIDING NECESSARY SPACE
ALLOCATION AND DIMENSIONS IN A TIMELY MANNER TO ALL PARTIES INVOLVED TO
ENSURE PROPER COORDINATION.
SCALE: THE DRAWINGS SHALL NOT BE SCALED; REFER TO DIMENSIONS WHERE
PROVIDED.
GENERAL REQUIREMENTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
BID OPTIONS
PEDESTRIAN BRIDGE:
1a: PEDESTRIAN BRIDGE 1b: PEDESTRIAN BRIDGE STAINLESS STEEL PROTECTIVE MESH
EAST CAMPUS QUADRANGLE:
2a: MEDALLION WITH LIGHTING 2b: STONE MOSAIC PLAZA 2c: SIDEWALK TEXTURING 2d: ENHANCED LANDSCAPING 2e: GATEWAY MARKERS WITH LIGHTING 2f: DCF MARKERS WITH LIGHTING 2g: STONE VENEER ON TERRACED WALLS
ATC 4:
3: INSTALLATION OF GOVERNMENT FURNISHED LOCKABLE
TELECOMM CABINETS
4: CID (O&M)
DOCUMENT WAS AUTHORIZED
THE SEAL APPEARING ON THIS
BY DAVID EVANS
21459 ON 1 SEPTEMBER 2011
R
EG
IS
TERED ARCH
IT
EC
T
DA
V ID EVANS
95412 SAXETFOETAT
S
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
/2
8/
1:
:4
A M
D A
V E
E V
A N
S
L U
IS
A
D A
V
IL
A
D A
V E
E V
A N
S
A4-G001
D R
AW
IN
G
IN
D
EX
, B
ID
O
PT
IO
N
S, A
N D
G
EN
ER
AL
R
EQ
U
IR
EM
EN
TS
VOLUME I
CIVIL
Sequence
No Sheet Number Sheet Name
23 A4-C101 DEMOLITION SITE PLAN
24 A4-C102 ELECTRICAL DEMOLITION SITE PLAN
25 A4-C103 COMMUNICATIONS DEMOLITION SITE PLAN
26 A4-C104 SURVEY CONTROL DATA PLAN
27 A4-C105 SITE LAYOUT PLAN
28 A4-C106 PAVING PLAN
29 A4-C107 GRADING SITE PLAN
30 A4-C108 UTILITY SITE PLAN
31 A4-C109 STORM WATER POLLUTION PREVENTION PLAN
32 A4-C110 GARY AVENUE PLAN AND PROFILE
33 A4-C111 DRAINAGE DITCH PLAN AND PROFILE
34 A4-C112 STORM DRAIN LINES A, A-1 AND A-2 PLANS AND PROFILES
35 A4-C113 STORM DRAIN LINE B PLAN AND PROFILE
36 A4-C114 STORM DRAIN LINES B-1, B-2 AND B-3 PLANS AND PROFILES
37 A4-C115 STORM DRAIN LINES C AND C-1 PLANS AND PROFILES
38 A4-C116 STORM DRAIN LINES C-2 AND D PLAN AND PROFILE
39 A4-C117 SANITARY SEWER LINES A AND B PLANS AND PROFILE
40 A4-C118 SANITARY SEWER LINES C, D AND E PLANS AND PROFILES
41 A4-C119 WATER LINE A PLAN AND PROFILE
42 A4-C120 WATER LINES A-1, A-2 AND B PLANS AND PROFILES
43 A4-C121 WATER LINE C PLAN AND PROFILE
44 A4-C122 WATER LINE D PLAN AND PROFILE
45 A4-C123 GAS LINE A PLAN AND PROFILE I
46 A4-C124 GAS LINE A PLAN AND PROFILE II
47 A4-C125 GAS LINE A PLAN AND PROFILE III
48 A4-C126 GAS LINE A-1 PLAN AND PROFILE
49 A4-C127 ELECTRICAL LINE A PLAN AND PROFILE
50 A4-C128 ELECTRICAL LINES B AND C PLANS AND PROFILES
51 A4-C129 ELECTRICAL LINE D PLAN AND PROFILE
52 A4-C130 ELECTRICAL LINE E PLAN AND PROFILE
53 A4-C131 COMMUNICATION LINE A PLAN AND PROFILE
54 A4-C401 ENLARGED BUILDING - ROOF DRAIN COLLECTION PLAN
55 A4-C402 SERVICE DRIVE AND SIDEWALK JOINTING PLAN
56 A4-C501 PAVING DETAILS
57 A4-C502 UTILITY DETAILS
58 A4-C503 DRAINAGE DETAILS
59 A4-C504 SANITARY SEWER DETAILS
60 A4-C505 REMOVABLE PIPE BOLLARD DETAILS
61 A4-C506 TEMPORARY EROSION SEDIMENT AND WATER POLLUTION CONTROL MEASURES
62 A4-C507 CONSTRUCTION FENCE DETAILS
63 A4-C508 FREE ZONE CONSTRUCTION FENCE DETAILS
64 A4-C509 JACKING AND BORING DETAILS
65 A4-ES101 ELECTRICAL SITE PLAN I
66 A4-ES102 ELECTRICAL SITE PLAN II
67 A4-ES501 ELECTRICAL ENLARGED TRANSFORMER YARD AND DETAILS
68 A4-ES502 ELECTRICAL DETAILS I
69 A4-ES503 ELECTRICAL DETAILS II
70 A4-ES504 ELECTRICAL DETAILS III
71 A4-ES505 JACKING AND BORING DETAILS
72 A4-ES506 POLE LINE DETAILS I
73 A4-ES507 POLE LINE DETAILS II
74 A4-ES508 POLE LINE DETAILS III
75 A4-ES509 POLE LINE DETAILS IV
76 A4-ES510 POLE LINE DETAILS V
A4-ES511 Unnamed
77 A4-ES601 ELECTRICAL SCHEDULES
78 A4-ES602 ELECTRICAL ONE-LINE DIAGRAM
STRUCTURAL
Sequence
No Sheet
Number Sheet Name
82 A4-S001 GENERAL NOTES
83 A4-S002 GENERAL NOTES
84 A4-S003 GENERAL NOTES AND ABBREVIATIONS
85 A4-S101 FOUNDATION OVERALL PLAN
86 A4-S102 FOUNDATION PLAN - AREA A
87 A4-S103 FOUNDATION PLAN - AREA B
88 A4-S104 FOUNDATION PLAN - AREA C
89 A4-S105 FOUNDATION PLAN - AREA D
90 A4-S106 GROUND FLOOR OVERALL SLAB PLAN
91 A4-S107 GROUND FLOOR SLAB PLAN - AREA A
92 A4-S108 GROUND FLOOR SLAB PLAN - AREA B
93 A4-S109 GROUND FLOOR SLAB PLAN - AREA C
94 A4-S110 GROUND FLOOR SLAB PLAN - AREA D
95 A4-S111 GROUND FLOOR TWO-WAY SLAB BOTTOM REINFORCING PLAN - AREA A
96 A4-S112 GROUND FLOOR TWO-WAY SLAB BOTTOM REINFORCING PLAN - AREA B
97 A4-S113 GROUND FLOOR TWO-WAY SLAB BOTTOM REINFORCING PLAN - AREA C
98 A4-S114 GROUND FLOOR TWO-WAY SLAB BOTTOM REINFORCING PLAN - AREA D
99 A4-S115 GROUND FLOOR TWO-WAY SLAB TOP REINFORCING PLAN - AREA A
100 A4-S116 GROUND FLOOR TWO-WAY SLAB TOP REINFORCING PLAN - AREA B
101 A4-S117 GROUND FLOOR TWO-WAY SLAB TOP REINFORCING PLAN - AREA C
102 A4-S118 GROUND FLOOR TWO-WAY SLAB TOP REINFORCING PLAN - AREA D
103 A4-S119 SECOND FLOOR OVERALL SLAB PLAN
104 A4-S120 SECOND FLOOR SLAB PLAN - AREA A
105 A4-S121 SECOND FLOOR SLAB PLAN - AREA B
106 A4-S122 SECOND FLOOR SLAB PLAN - AREA C
107 A4-S123 SECOND FLOOR SLAB PLAN - AREA D
108 A4-S124 SECOND FLOOR POST TENSIONING SLAB PLAN - AREA A
109 A4-S125 SECOND FLOOR POST TENSIONING SLAB PLAN - AREA B
110 A4-S126 SECOND FLOOR POST TENSIONING SLAB PLAN - AREA C
111 A4-S127 SECOND FLOOR POST TENSIONING SLAB PLAN - AREA D
112 A4-S128 THIRD AND FOURTH FLOOR OVERALL SLAB PLAN
113 A4-S129 THIRD AND FOURTH FLOOR SLAB PLAN - AREA A
114 A4-S130 THIRD AND FOURTH FLOOR SLAB PLAN - AREA B
115 A4-S131 THIRD AND FOURTH FLOOR SLAB PLAN - AREA C
116 A4-S132 THIRD AND FOURTH FLOOR SLAB PLAN - AREA D
117 A4-S133 THIRD AND FOURTH FLOOR POST TENSIONING SLAB PLAN - AREA A
118 A4-S134 THIRD AND FOURTH FLOOR POST TENSIONING SLAB PLAN - AREA B
119 A4-S135 THIRD AND FOURTH FLOOR POST TENSIONING SLAB PLAN - AREA C
120 A4-S136 THIRD AND FOURTH FLOOR POST TENSIONING SLAB PLAN - AREA D
121 A4-S137 PENTHOUSE OVERALL SLAB PLAN
122 A4-S138 PENTHOUSE SLAB PLAN - AREA A
123 A4-S139 PENTHOUSE SLAB PLAN - AREA B
124 A4-S140 PENTHOUSE SLAB PLAN - AREA C
125 A4-S141 PENTHOUSE SLAB PLAN - AREA D
126 A4-S142 PENTHOUSE POST TENSIONING SLAB PLAN - AREA A
127 A4-S143 PENTHOUSE POST TENSIONING SLAB PLAN - AREA B
128 A4-S144 PENTHOUSE POST TENSIONING SLAB PLAN - AREA C
129 A4-S145 PENTHOUSE POST TENSIONING SLAB PLAN - AREA D
130 A4-S146 ROOF OVERALL FRAMING PLAN
131 A4-S147 LOW ROOF FRAMING PLAN - AREA A
132 A4-S148 LOW ROOF FRAMING PLAN - AREA B
133 A4-S149 LOW ROOF FRAMING PLAN - AREA C
134 A4-S150 LOW ROOF FRAMING PLAN - AREA D
135 A4-S151 HIGH ROOF FRAMING PLAN
136 A4-S201 TRUSS ELEVATIONS
137 A4-S301 SHEAR WALL ELEVATIONS
138 A4-S302 SHEAR WALL ELEVATIONS
139 A4-S401 MECHANICAL YARD, STAIRS AND MISCELLANEOUS PLANS
140 A4-S402 ENLARGED HANGING TOILET PARTITION SUPPORT
141 A4-S501 TYPICAL CONCRETE DETAILS
142 A4-S502 CONCRETE DETAILS
143 A4-S503 TYPICAL COLUMN DETAILS
144 A4-S504 TYPICAL TWO-WAY SLAB DETAILS AT GROUND FLOOR
145 A4-S505 TWO-WAY SLAB DETAILS
146 A4-S506 TYPICAL POST TENSIONED SLAB DETAILS
147 A4-S507 TYPICAL CONCRETE BEAM SECTIONS AND DETAILS
148 A4-S508 TYPICAL MASONRY SECTIONS AND DETAILS
149 A4-S509 TYPICAL FRAMING DETAILS
150 A4-S510 TRUSS AND MISCELLANEOUS DETAILS
151 A4-S511 HIGH ROOF DETAILS
152 A4-S512 FRAMING DETAILS
153 A4-S513 FRAMING DETAILS
154 A4-S514 SECOND, THIRD AND FOURTH FLOOR BEAM TO COLUMN INTERSECTIONS
155 A4-S515 SECOND, THIRD, AND FOURTH FLOOR BEAM TO COLUMN INTERSECTIONS
156 A4-S516 PENTHOUSE BEAM TO COLUMN INTERSECTIONS
157 A4-S517 PENTHOUSE BEAM TO COLUMN INTERSECTIONS
158 A4-S518 SECOND, THIRD, FOURTH AND PENTHOUSE FLOOR BEAM TO COLUMN
INTERSECTIONS
159 A4-S601 WIND LOAD DIAGRAMS
160 A4-S602 CONCRETE COLUMN AND SHEAR WALL SCHEDULES
161 A4-S603 CONCRETE BEAM SCHEDULES
162 A4-S604 CONCRETE BEAM SCHEDULES
163 A4-S605 CONCRETE BEAM SCHEDULES
164 A4-S606 CONCRETE BEAM SCHEDULES
165 A4-S607 TYPICAL LIGHT GAGE STEEL SECTION, DETAILS AND SCHEDULES
INTERIORS
Sequence
No Sheet
Number Sheet Name
245 A4-I101 GROUND FLOOR FURNITURE PLAN
246 A4-I102 SECOND FLOOR FURNITURE PLAN - AREA A
247 A4-I201 INTERIOR ELEVATIONS
248 A4-I401 ENLARGED PLANS
249 A4-I402 ENLARGED PLANS
250 A4-I501 INTERIOR SECTIONS AND DETAILS
251 A4-I601 FINISH SELECTIONS AND FINISH SCHEDULE #1
252 A4-I602 FINISH SCHEDULE #2
253 A4-I603 FINISH SCHEDULE #3
ARCHITECTURAL
Sequence
No Sheet
Number Sheet Name
166 A4-A001 ABBREVIATIONS AND ARCHITECTURAL SYMBOLS
167 A4-A002 LIFE SAFETY PLAN GROUND FLOOR
168 A4-A003 LIFE SAFETY PLAN FLOORS 2 - 4 TYPICAL AREA
169 A4-A004 PENTHOUSE LIFE SAFETY PLAN
170 A4-A101 CRAWL SPACE OVERALL PLAN
171 A4-A102 GROUND FLOOR OVERALL PLAN
172 A4-A103 GROUND FLOOR PLAN - AREA A
173 A4-A104 GROUND FLOOR PLAN - AREA B
174 A4-A105 GROUND FLOOR PLAN - AREA C
175 A4-A106 GROUND FLOOR PLAN - AREA D
176 A4-A107 SECOND FLOOR OVERALL PLAN
177 A4-A108 SECOND FLOOR PLAN - AREA A
178 A4-A109 SECOND FLOOR PLAN - AREA B
179 A4-A110 SECOND FLOOR PLAN - AREA C
180 A4-A111 SECOND FLOOR PLAN - AREA D
181 A4-A112 THIRD FLOOR OVERALL PLAN
182 A4-A113 THIRD FLOOR PLAN - AREA A
183 A4-A114 THIRD FLOOR PLAN - AREA B
184 A4-A115 THIRD FLOOR PLAN - AREA C
185 A4-A116 THIRD FLOOR PLAN - AREA D
186 A4-A117 FOURTH FLOOR OVERALL PLAN
187 A4-A118 FOURTH FLOOR PLAN - AREA A
188 A4-A119 FOURTH FLOOR PLAN - AREA B
189 A4-A120 FOURTH FLOOR PLAN - AREA C
190 A4-A121 FOURTH FLOOR PLAN - AREA D
191 A4-A122 PENTHOUSE PLAN
192 A4-A123 ROOF PLAN
193 A4-A124 GROUND FLOOR OVERALL REFLECTED CEILING PLAN
194 A4-A125 GROUND FLOOR REFLECTED CEILING PLAN - AREA A
195 A4-A126 GROUND FLOOR REFLECTED CEILING PLAN - AREA B
196 A4-A127 GROUND FLOOR REFLECTED CEILING PLAN - AREA C
197 A4-A128 GROUND FLOOR REFLECTED CEILING PLAN - AREA D
198 A4-A129 SECOND AND THIRD FLOOR OVERALL REFLECTED CEILING PLAN
199 A4-A130 SECOND AND THIRD FLOOR REFLECTED CEILING PLAN - AREA A
200 A4-A131 SECOND AND THIRD FLOOR REFLECTED CEILING PLAN - AREA B
201 A4-A132 SECOND AND THIRD FLOOR REFLECTED CEILING PLAN - AREA C
202 A4-A133 SECOND AND THIRD FLOOR REFLECTED CEILING PLAN - AREA D
203 A4-A134 FOURTH FLOOR OVERALL REFLECTED CEILING PLAN
204 A4-A135 FOURTH FLOOR REFLECTED CEILING PLAN - AREA A
205 A4-A136 FOURTH FLOOR REFLECTED CEILING PLAN - AREA B
206 A4-A137 FOURTH FLOOR REFLECTED CEILING PLAN - AREA C
207 A4-A138 FOURTH FLOOR REFLECTED CEILING PLAN - AREA D
208 A4-A139 PENTHOUSE REFLECTED CEILING PLAN
209 A4-A201 SOUTH AND EAST EXTERIOR ELEVATIONS
210 A4-A202 NORTH AND WEST EXTERIOR ELEVATIONS
211 A4-A203 EXTERIOR ELEVATIONS GROUND FLOOR
212 A4-A301 BUILDING SECTIONS
213 A4-A401 ENLARGED PLANS
214 A4-A402 ENLARGED PLANS
215 A4-A403 CANOPY PLANS, ELEVATIONS AND DETAILS
216 A4-A404 ENLARGED ORIEL WINDOW PLANS AND ELEVATION
217 A4-A405 ELEVATOR PLANS, SECTIONS AND DETAILS
218 A4-A406 STAIR B PLANS AND SECTIONS
219 A4-A407 STAIR A PLANS AND SECTIONS
220 A4-A408 STAIR DETAILS
221 A4-A409 MECHANICAL YARD AND TRANSFORMER YARD PLANS AND ELEVATIONS
222 A4-A410 ENLARGED WINDOW PLANS AND ELEVATIONS
223 A4-A411 ENLARGED WINDOW PLANS AND ELEVATIONS
224 A4-A412 ENLARGED PLANS
225 A4-A413 ENLARGED PLANS
226 A4-A501 PARTITION TYPES
227 A4-A502 DETAILS
228 A4-A503 EXTERIOR WALL SECTIONS
229 A4-A504 WALL SECTIONS
230 A4-A505 WALL SECTION AND DETAILS
231 A4-A506 PLAN DETAILS
232 A4-A507 PLAN DETAILS
233 A4-A508 SECTION DETAILS
234 A4-A509 DETAILS
235 A4-A510 ROOF HATCH ENLARGED PLAN, DETAILS AND CEILING DETAILS
236 A4-A511 ROOF HATCH AND DORMER DETAILS
237 A4-A512 ROOF DETAILS
238 A4-A513 SKYLIGHT PLAN, ELEVATIONS AND DETAILS
239 A4-A601 DOOR SCHEDULE GROUND FLOOR, FRAME TYPES, DOOR TYPES AND SIGN DETAILS
240 A4-A602 DOOR SCHEDULE SECOND FLOOR
241 A4-A603 DOOR SCHEDULE THIRD FLOOR
242 A4-A604 DOOR SCHEDULE FOURTH FLOOR AND PENTHOUSE
243 A4-A605 WINDOW SCHEDULE AND DETAILS
244 A4-A606 DOOR DETAILS
GENERAL
Sequence
No Sheet
Number Sheet Name
1 A4-G001 DRAWING INDEX, BID OPTIONS, AND GENERAL REQUIREMENTS
2 A4-G002 DRAWING INDEX
3 A4-G003 PROJECT LOCATION PLAN
4 A4-G004 EAST CAMPUS LAYOUT PLAN
5 A4-G005 CAMPUS PHASING PLAN
6 A4-G006 CONSTRUCTION PHASING PLAN
7 A4-G007 CONSTRUCTION PHASING PHASE 4A AND 4B PLANS
8 A4-G008 CONSTRUCTION PHASING PHASE 4C, 4D, 4E AND 4F PLAN
9 A4-G009 TEMPORARY UTILITY SITE PLAN
79 A4-CS101 COMMUNICATIONS SITE PLAN
80 A4-CS501 COMMUNICATIONS MANHOLE DETAILS
81 A4-CS502 CONCRETE ENCASED CONDUIT DETAILS
CIVIL-TOPOGRAPHICAL
Sequence
No Sheet Number Sheet Name
15 A4-V101 TOPOGRAPHICAL SURVEY SHEET 1 OF 4
16 A4-V102 TOPOGRAPHICAL SURVEY SHEET 2 OF 4
17 A4-V103 TOPOGRAPHICAL SURVEY SHEET 3 OF 4
18 A4-V104 TOPOGRAPHICAL SURVEY SHEET 4 OF 4
CIVIL- AD SERIES
Sequence
No Sheet Number Sheet Name
19 A4-AD101 BUILDING 6275 FIRST FLOOR DEMOLITION PLAN
20 A4-AD102 BUILDING 6275 SECOND FLOOR DEMOLITION PLAN
21 A4-AD103 BUILDING 6275 THIRD FLOOR DEMOLITION PLAN
22 A4-AD104 BUILDING 6359 DEMOLITION FLOOR PLAN
BORING LOGS
Sequence
No Sheet
Number Sheet Name
10 A4-B101 BORING LOCATIONS
11 A4-B201 LOGS OF BORINGS - 1 OF 4
12 A4-B202 LOGS OF BORINGS - 2 OF 4
13 A4-B203 LOGS OF BORINGS - 3 OF 4
14 A4-B204 LOGS OF BORINGS - 4 OF 4
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D at e
DOCUMENT WAS AUTHORIZED
THE SEAL APPEARING ON THIS
BY DAVID EVANS
21459 ON 1 SEPTEMBER 2011
R
EG
IS
TERED ARCH
IT
EC
T
DA
V ID EVANS
95412 SAXETFOETAT
S
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
8/
/2
3:
:2
P
M
D A
V E
E V
A N
S
L U
IS
A
D A
V
IL
A
D A
V E
E V
A N
S
A4-G002
D R
AW
IN
G
IN
D
EX
VOLUME II
406 A4-TN101 GROUND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA A
407 A4-TN102 GROUND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA B
408 A4-TN103 GROUND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA C
409 A4-TN104 GROUND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA D
410 A4-TN105 SECOND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA A
411 A4-TN106 SECOND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA B
412 A4-TN107 SECOND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA C
413 A4-TN108 SECOND FLOOR TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREA D
414 A4-TN109 THIRD FLOOR OVERALL TELECOMMUNICATION AND SECURITY SYSTEMS PLAN
415 A4-TN110 FOURTH FLOOR OVERALL TELECOMMUNICATION AND SECURITY SYSTEMS PLAN
416 A4-TN111 PENTHOUSE TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREAS A AND B 417 A4-TN112 PENTHOUSE TELECOMMUNICATION AND SECURITY SYSTEMS PLAN - AREAS C AND D
418 A4-TN401 GROUND FLOOR COMMUNICATIONS ROOMS - ENLARGED PLANS AND ELEVATIONS
419 A4-TN402 SECOND FLOOR COMMUNICATIONS ROOMS - ENLARGED PLANS AND ELEVATIONS
420 A4-TN501 TELECOMMUNICATION SYSTEM DETAILS
421 A4-TN502 A/V SYSTEM AND CATV SYSTEM RISER DIAGRAMS
422 A4-TN601 GROUND FLOOR TELECOMMUNICATION SYSTEM RISER DIAGRAM
423 A4-TN602 SECOND FLOOR TELECOMMUNICATION SYSTEM RISER DIAGRAM
424 A4-TN603 THIRD FLOOR TELECOMMUNICATION SYSTEM RISER DIAGRAM
425 A4-TN604 FOURTH FLOOR TELECOMMUNICATION SYSTEM RISER DIAGRAM
426 A4-TN605 TELECOMMUNICATION SYSTEM BACKBONE AND GROUNDING RISER DIAGRAM
427 A4-TN606 CCTV SYSTEM RISER DIAGRAM
428 A4-TN607 SECURITY SYSTEM RISER DIAGRAM
429 A4-TN608 INTERCOM PAGING RISER DIAGRAM
390 A4-FA101 GROUND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA A
391 A4-FA102 GROUND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA B
392 A4-FA103 GROUND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA C
393 A4-FA104 GROUND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA D
394 A4-FA105 SECOND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA A
395 A4-FA106 SECOND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA B
396 A4-FA107 SECOND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA C
397 A4-FA108 SECOND FLOOR FIRE ALARM / MASS NOTIFICATION PLAN - AREA D
398 A4-FA109 THIRD FLOOR OVERALL FIRE ALARM / MASS NOTIFICATION PLAN
399 A4-FA110 FOURTH FLOOR OVERALL FIRE ALARM / MASS NOTIFICATION PLAN
400 A4-FA111 PENTHOUSE FIRE ALARM / MASS NOTIFICATION PLAN - AREAS A AND B
401 A4-FA112 PENTHOUSE FIRE ALARM / MASS NOTIFICATION PLAN - AREAS C AND D
402 A4-FA601 GROUND AND SECOND FLOORS FIRE ALARM / MASS NOTIFICATION SYSTEMS RISER
DIAGRAM
403 A4-FA602 THIRD FLOOR FIRE ALARM / MASS NOTIFICATION SYSTEMS RISER DIAGRAM
404 A4-FA603 FOURTH FLOOR AND PENTHOUSE FIRE ALARM / MASS NOTIFICATION SYSTEMS RISER
DIAGRAM
405 A4-FA604 FIRE ALARM / MASS NOTIFICATION CONTROL MATRIX AND DETAILS
PEDESTRIAN BRIDGE
BID OPTION 1a
EAST CAMPUS QUADRANGLE
EAST CAMPUS - STRUCTURAL
Sequence
No Sheet
Number Sheet Name
39 EC-S001 GENERAL NOTES
40 EC-S100 PLAZA PLAN AND SECTION - BASE BID
41 EC-S101 PLAZA PLAN AND SECTION - BID OPTION 2A
42 EC-S501 TYPICAL CONCRETE DETAILS - BASE BID
43 EC-S502 TYPICAL CONCRETE DETAILS - BID OPTIONS 2A, 2E AND 2F
EAST CAMPUS - LANDSCAPE
Sequence
No Sheet
Number Sheet Name
24 EC-L101 LANDSCAPE LAYOUT PLAN
25 EC-L102 PLANTING PLAN BASE BID
26 EC-L103 PLANTING PLAN BID OPTION 2D
27 EC-L104 LANDSCAPE UNDERGROUND IRRIGATION PLAN BASE BID
28 EC-L105 LANDSCAPE UNDERGROUND IRRIGATION PLAN BID OPTION 2D
29 EC-L301 SECTION ELEVATIONS
30 EC-L401 SITE PLAN ENLARGEMENT - AREA A
31 EC-L402 SITE PLAN ENLARGEMENT - AREA B
32 EC-L403 SITE PLAN ENLARGEMENT - AREA C
33 EC-L404 SITE PLAN ENLARGEMENT - AREA D
34 EC-L501 SITE DETAILS
35 EC-L502 SITE DETAILS
36 EC-L503 PLANTING NOTES AND DETAILS
37 EC-L504 LANDSCAPE UNDERGROUND IRRIGATION DETAILS
38 EC-L505 LANDSCAPE UNDERGROUND IRRIGATION NOTES
EAST CAMPUS - ELECTRICAL
Sequence
No Sheet
Number Sheet Name
50 EC-ES100 ELECTRICAL SITE PLAN OVERALL AND LEGEND
51 EC-ES101 ELECTRICAL SITE PLAN AREA A
52 EC-ES102 ELECTRICAL SITE PLAN AREA B
53 EC-ES103 ELECTRICAL SITE PLAN AREA C
54 EC-ES104 ELECTRICAL SITE PLAN AREA D
55 EC-ES501 SITE ELECTRICAL DETAILS
EAST CAMPUS - CIVIL
Sequence
No Sheet
Number Sheet Name
9 EC-B101 EAST CAMPUS QUADRANGLE BORING LOCATIONS AND LOGS OF
BORINGS
10 EC-C101 EAST CAMPUS QUADRANGLE DEMOLITION SITE PLAN
11 EC-C102 EAST CAMPUS QUADRANGLE SITE LAYOUT PLAN
12 EC-C103 EAST CAMPUS QUADRANGLE PAVING PLAN
13 EC-C104 EAST CAMPUS QUADRANGLE GRADING SITE PLAN
14 EC-C105 EAST CAMPUS QUADRANGLE UTILITY SITE PLAN
15 EC-C106 EAST CAMPUS QUADRANGLE STORM WATER POLLUTION PREVENTION
PLAN
16 EC-C107 EAST CAMPUS SIDEWALK A PLAN AND PROFILE
17 EC-C108 EAST CAMPUS SIDEWALK B PLAN AND PROFILE
18 EC-C109 EAST CAMPUS QUADRANGLE - STORM DRAIN LINE A - PLAN AND PROFILE
19 EC-C110 EAST CAMPUS QUADRANGLE - STORM DRAIN LINES B AND C - PLAN AND
PROFILE
20 EC-C401 EAST CAMPUS QUADRANGLE ENLARGED SUBDRAIN LINE PLAN AND
DETAILS
21 EC-C402 EAST CAMPUS QUADRANGLE ENLARGED GRADING PLAN
22 EC-C501 EAST CAMPUS QUADRANGLE MISCELLANEOUS DETAILS
23 EC-C502 EAST CAMPUS QUADRANGLE TEMPORARY EROSION SEDIMENT AND
WATER POLLUTION CONTROL MEASURES
EAST CAMPUS - ARCHITECTURAL (SITE FEATURES ELEMENTS DESIGN)
Sequence
No Sheet
Number Sheet Name
44 EC-A100 PLAZA AND WALK PLAN
45 EC-A101 PLAZA PLAN AND SECTIONS (BID OPTIONS)
46 EC-A102 PLAZA PLAN AND SECTIONS (BASE BID)
47 EC-A103 PLAZA PLAN (BID OPTIONS)
48 EC-A200 GATEWAY MARKERS AND DCF MARKERS (BID OPTIONS)
49 EC-A201 WALLS FINISH / VENEER DETAILS (BID OPTIONS 2G)
PEDESTRIAN BRIDGE - STRUCTURAL
Sequence
No Sheet
Number Sheet Name
14 P4-S001 GENERAL NOTES - BID OPTION 1A
15 P4-S002 GENERAL NOTES AND ABBREVIATIONS - BID OPTIONS 1A
16 P4-S101 FOUNDATION PLAN - BID OPTION 1A
17 P4-S102 PLAN AND ELEVATION - AREA A - BID OPTION 1A
18 P4-S103 PLAN AND ELEVATION - AREA B - BID OPTION 1A
19 P4-S201 ARCH ELEVATION - BID OPTION 1A
20 P4-S501 TYPICAL DETAILS - BID OPTION 1A
21 P4-S502 ABUTMENT PLAN, SECTIONS AND DETAILS - BID OPTION 1A
22 P4-S503 BENT PLAN, SECTIONS AND DETAILS - BID OPTION 1A
23 P4-S504 DECK SLAB AND CURB DETAILS - BID OPTION 1A
24 P4-S505 PRESTRESSED CONCRETE I-BEAM DETAILS - BID OPTION 1A
25 P4-S506 ELASTOMERIC BEARING AND BEAM END DETAILS - BID OPTION 1A
26 P4-S507 MISCELLANEOUS DETAILS - BID OPTION 1A
27 P4-S508 ARCH SECTIONS AND DETAILS - BID OPTION 1A
PEDESTRIAN BRIDGE - ELECTRICAL
Sequence
No Sheet
Number Sheet Name
32 P4-EL101 LIGHTING AND DETAILS BID OPTION 1A
VOLUME III
FIRE PROTECTION
Sequence
No Sheet
Number Sheet Name
254 A4-F001 FIRE PROTECTION LEGEND AND NOTES
255 A4-F100 GROUND FLOOR FIRE PROTECTION PLAN - AREA A
256 A4-F101 GROUND FLOOR FIRE PROTECTION PLAN - AREA B
257 A4-F102 GROUND FLOOR FIRE PROTECTION PLAN - AREA C
258 A4-F103 GROUND FLOOR FIRE PROTECTION PLAN - AREA D
259 A4-F104 SECOND THROUGH FOURTH FLOOR FIRE PROTECTION PLAN - AREA A
260 A4-F105 SECOND THROUGH FOURTH FLOOR FIRE PROTECTION PLAN - AREA B
261 A4-F106 SECOND THROUGH FOURTH FLOOR FIRE PROTECTION PLAN - AREA C
262 A4-F107 SECOND THROUGH FOURTH FLOOR FIRE PROTECTION PLAN - AREA D
263 A4-F108 PENTHOUSE FIRE PROTECTION PLAN - AREA A
264 A4-F109 PENTHOUSE FIRE PROTECTION PLAN - AREA B
265 A4-F110 PENTHOUSE FIRE PROTECTION PLAN - AREA C
266 A4-F111 PENTHOUSE FIRE PROTECTION PLAN - AREA D
267 A4-F501 FIRE PROTECTION DETAILS
268 A4-F601 FIRE PROTECTION OCCUPANCY SCHEDULE
269 A4-F602 FIRE PROTECTION OCCUPANCY SCHEDULE
PLUMBING
Sequence
No Sheet
Number Sheet Name
270 A4-P001 PLUMBING LEGEND
271 A4-P101 CRAWL SPACE OVERALL PLUMBING PLAN
272 A4-P102 GROUND FLOOR OVERALL PLUMBING PLAN
273 A4-P103 SECOND AND THIRD FLOOR OVERALL PLUMBING PLAN
274 A4-P104 FOURTH FLOOR OVERALL PLUMBING PLAN
275 A4-P105 PENTHOUSE OVERALL PLUMBING PLAN
276 A4-P106 MECHANICAL YARD PLUMBING PLAN
277 A4-P401 ENLARGED CRAWL SPACE RESTROOM PLANS
278 A4-P402 ENLARGED RESTROOM PLUMBING PLANS
279 A4-P403 ENLARGED PLUMBING PLANS
280 A4-P404 ENLARGED MECHANICAL ROOM PLUMBING PLANS
281 A4-P405 ENLARGED MECHANICAL ROOM PLANS
282 A4-P501 PLUMBING DETAILS
283 A4-P502 PLUMBING DETAILS
284 A4-P601 PLUMBING SCHEDULES
285 A4-P901 PLUMBING ISOMETRIC PLANS
286 A4-P902 PLUMBING ISOMETRIC PLANS
287 A4-P903 PLUMBING PIPING RISER ISOMETRIC PLANS - AREAS A - D
288 A4-P904 PLUMBING ISOMETRIC PLANS
289 A4-P905 PLUMBING ISOMETRIC PLANS
290 A4-P906 PLUMBING ISOMETRIC PLANS
291 A4-P907 PLUMBING ISOMETRIC PLANS
292 A4-P908 PLUMBING FUEL GAS ISOMETRIC PLAN
293 A4-P909 PLUMBING ISOMETRIC PLANS
MECHANICAL
Sequence
No Sheet
Number Sheet Name
294 A4-M001 HVAC LEGEND AND GENERAL NOTES
295 A4-M100 CRAWL SPACE OVERALL HVAC AND HYDRONIC PLAN
296 A4-M101 GROUND FLOOR OVERALL HVAC PLAN
297 A4-M102 SECOND FLOOR OVERALL HVAC PLAN
298 A4-M103 THIRD FLOOR OVERALL HVAC PLAN
299 A4-M104 FOURTH FLOOR OVERALL HVAC PLAN
300 A4-M105 PENTHOUSE OVERALL HVAC PLAN
301 A4-M106 GROUND FLOOR HVAC PLAN - AREA A
302 A4-M107 GROUND FLOOR HVAC PLAN - AREA D
303 A4-M108 SECOND THROUGH FOURTH FLOOR TYPICAL HVAC PLAN - AREA A
304 A4-M109 SECOND THROUGH FOURTH FLOOR TYPICAL HVAC PLAN - AREAS B, C AND D
305 A4-M110 PENTHOUSE HVAC FLOOR PLAN - AREA A
306 A4-M111 PENTHOUSE HVAC FLOOR PLAN - AREA B
307 A4-M112 PENTHOUSE HVAC FLOOR PLAN - AREA C
308 A4-M113 PENTHOUSE HVAC FLOOR PLAN - AREA D
309 A4-M114 GROUND FLOOR HYDRONIC PIPING PLAN - AREA A
310 A4-M115 GROUND FLOOR HYDRONIC PIPING PLAN - AREA D
311 A4-M116 PENTHOUSE HYDRONIC PIPING PLAN - AREA A
312 A4-M117 PENTHOUSE HYDRONIC PIPING PLAN - AREA B
313 A4-M118 PENTHOUSE HYDRONIC PIPING PLAN - AREA C
314 A4-M119 PENTHOUSE HYDRONIC PIPING PLAN - AREA D
315 A4-M301 HVAC SECTIONS
316 A4-M302 HYDRONIC PIPING SECTIONS
317 A4-M303 HVAC SECTIONS
318 A4-M304 HVAC SECTIONS
319 A4-M401 ENLARGED MECHANICAL ROOM PLANS AND SECTION
320 A4-M402 ENLARGED MECHANICAL PLANS
321 A4-M403 ENLARGED MECHANICAL PLANS
322 A4-M501 HVAC DETAILS
323 A4-M502 HVAC DETAILS
324 A4-M601 HVAC SCHEDULES
325 A4-M602 HVAC SCHEDULES
326 A4-M603 HEATING WATER FLOW DIAGRAM
327 A4-M604 CHILLED WATER FLOW DIAGRAM
328 A4-M605 HVAC CONTROLS
329 A4-M606 HVAC CONTROLS
330 A4-M607 HVAC CONTROLS
331 A4-M608 HVAC CONTROLS
332 A4-M609 HVAC CONTROLS
333 A4-M610 HVAC CONTROLS
ELECTRICAL
Sequence
No Sheet
Number Sheet Name
334 A4-E-001 ELECTRICAL SYMBOL LEGENDS AND ABBREVIATIONS
335 A4-EL101 GROUND FLOOR LIGHTING PLAN - AREA A
336 A4-EL102 GROUND FLOOR LIGHTING PLAN - AREA B
337 A4-EL103 GROUND FLOOR LIGHTING PLAN - AREA C
338 A4-EL104 GROUND FLOOR LIGHTING PLAN - AREA D
339 A4-EL105 SECOND FLOOR LIGHTING PLAN - AREA A
340 A4-EL106 SECOND FLOOR LIGHTING PLAN - AREA B
341 A4-EL107 SECOND FLOOR LIGHTING PLAN - AREA C
342 A4-EL108 SECOND FLOOR LIGHTING PLAN - AREA D
343 A4-EL109 THIRD FLOOR OVERALL LIGHTING PLAN
344 A4-EL110 FOURTH FLOOR OVERALL LIGHTING PLAN
345 A4-EL111 PENTHOUSE LIGHTING PLAN - AREAS A AND B
346 A4-EL112 PENTHOUSE LIGHTING PLAN - AREAS D AND C
347 A4-EL501 LIGHTING FIXTURE DETAILS
348 A4-EL502 LIGHTING FIXTURE DETAILS
349 A4-EL503 LIGHTING CONTROL DETAILS AND SCHEDULES
350 A4-EP101 GROUND FLOOR POWER PLAN - AREA A
351 A4-EP102 GROUND FLOOR POWER PLAN - AREA B
352 A4-EP103 GROUND FLOOR POWER PLAN - AREA C
353 A4-EP104 GROUND FLOOR POWER PLAN - AREA D
354 A4-EP105 SECOND FLOOR POWER PLAN - AREA A
355 A4-EP106 SECOND FLOOR POWER PLAN - AREA B
356 A4-EP107 SECOND FLOOR POWER PLAN - AREA C
357 A4-EP108 SECOND FLOOR POWER PLAN - AREA D
358 A4-EP109 THIRD FLOOR OVERALL POWER PLAN
359 A4-EP110 FOURTH FLOOR OVERALL POWER PLAN
360 A4-EP111 PENTHOUSE ENLARGED POWER PLAN - AREAS A AND B
361 A4-EP112 PENTHOUSE ENLARGED POWER PLAN - AREAS C AND D
362 A4-EP401 CRAWL SPACE POWER AND LIGHTING PLAN - AREAS A AND B
363 A4-EP402 CRAWL SPACE POWER AND LIGHTING PLAN - AREAS C AND D
364 A4-EP403 EQUIPMENT YARDS ENLARGED SITE POWER PLAN - AREA A
365 A4-EP404 GROUND FLOOR MECHANICAL AND ELECTRICAL ROOM ENLARGED POWER PLANS
366 A4-EP405 SECOND FLOOR MECHANICAL AND ELECTRICAL ROOM ENLARGED POWER PLANS
367 A4-EP406 THIRD FLOOR MECHANICAL AND ELECTRICAL ROOM ENLARGED POWER PLANS
368 A4-EP407 FOURTH FLOOR MECHANICAL AND ELECTRICAL ROOM ENLARGED POWER PLANS
369 A4-EP408 TYPICAL ELECTRICAL ROOM ELEVATIONS AND ENLARGED PLANS
370 A4-EP409 MAIN ELECTRICAL ROOM A123 ELEVATIONS
371 A4-EP501 ELECTRICAL DETAILS
372 A4-EP502 GENERATOR INSTALLATION DETAILS
373 A4-EP601 ELECTRICAL ONE-LINE DIAGRAM
374 A4-EP602 ELECTRICAL SCHEDULES
375 A4-EP603 MECHANICAL EQUIPMENT SCHEDULES
376 A4-EP604 PANEL SCHEDULES
377 A4-EP605 PANEL SCHEDULES
378 A4-EP606 PANEL SCHEDULES
379 A4-EP607 PANEL SCHEDULES
380 A4-EP608 PANEL SCHEDULES
381 A4-EP609 PANEL SCHEDULES
382 A4-EP610 PANEL SCHEDULES
383 A4-EP611 PANEL SCHEDULES
384 A4-EP612 PANEL SCHEDULES
385 A4-EP613 PANEL SCHEDULES
386 A4-EP614 PANEL SCHEDULES
387 A4-EG101 ROOF LIGHTNING PROTECTION PLAN
388 A4-EG501 GROUNDING / LIGHTNING PROTECTION SYSTEM DETAILS
389 A4-EG601 GROUNDING SYSTEM RISER DIAGRAM
PEDESTRIAN BRIDGE - GENERAL - VOLUME III
Sequence
No Sheet
Number Sheet Name
1 A4-G001 DRAWING INDEX, BID OPTIONS, AND GENERAL REQUIREMENTS
2 A4-G002 DRAWING INDEX
EAST CAMPUS - GENERAL - VOLUME IV
Sequence
No Sheet
Number Sheet Name
1 A4-G001 DRAWING INDEX, BID OPTIONS, AND GENERAL REQUIREMENTS
2 A4-G002 DRAWING INDEX
3 EC-G003 EAST CAMPUS QUADRANGLE PROJECT LOCATION PLAN
4 EC-G004 EAST CAMPUS QUADRANGLE CONSTRUCTION AREA PLAN
5 EC-G005 EAST CAMPUS QUADRANGLE CONSTRUCTION FENCE PHASING PLANS I
6 EC-G006 EAST CAMPUS QUADRANGLE CONSTRUCTION FENCE PHASING PLANS II
7 EC-G007 EAST CAMPUS QUADRANGLE CONSTRUCTION FENCE PAHSING PLANS III
8 EC-G008 EAST CAMPUS QUADRANGLE - PHASING PLAN
VOLUME IV
PEDESTRIAN BRIDGE - CIVIL
Sequence
No Sheet
Number Sheet Name
6 P4-B101 BORING LOCATIONS AND LOGS OF BORINGS
7 P4-C101 BID OPTION 1A DEMOLITION SITE AND ELECTRICAL PLANS
8 P4-C102 BID OPTION 1A SITE LAYOUT AND GRADING PLANS
9 P4-C103 STORM DRAIN LINE - PLAN AND PROFILE
10 P4-C501 MISCELLANEOUS DETAILS
11 P4-C502 TEMPORARY EROSION SEDIMENT AND WATER POLLUTION CONTROL
MEASURES
12 P4-C503 CONSTRUCTION FENCE DETAILS
13 P4-C504 FREE ZONE CONSTRUCTION FENCE DETAILS
PEDESTRIAN BRIDGE - ARCHITECTURAL
Sequence
No Sheet
Number Sheet Name
28 P4-A100 PLANS
29 P4-A101 ELEVATIONS - BID OPTION 1A
30 P4-A501 DETAILS - BID OPTION 1A
31 P4-A502 DETAILS - BID OPTION 1A
GENERAL - VOLUME II
Sequence
No Sheet
Number Sheet Name
1 A4-G001 DRAWING INDEX, BID OPTIONS, AND GENERAL REQUIREMENTS
2 A4-G002 DRAWING INDEX
3 P4-G003 PROJECT LOCATION PLAN
4 P4-G004 CONSTRUCTION AREA PLAN
5 P4-G005 AREA PLAN - BID OPTION 1A
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D
DUAL CHECK VALVE/ BACK FLOW PREVENTER
ELEVATOR
FIRE DAMPER
FIRE DEPARTMENT CONNECTION VALVE
FIRE DEPARTMENT CONNECTION
FIRE DEPARTMENT
FIRE EXTINGUISHER CABINET
FIRE HYDRANT
FIRE HOSE CABINET
FIRE PUMP
FIRE VALVE CABINET
GALLONS PER MINUTE
JOCKEY PUMP
PULL BOX
POST INDICATOR VALVE
POUNDS PER SQUARE INCH
TAMPER SWITCH
DCVA / BFP
ELEV.
FD
FDCV
FDC
FIRE DEPT.
FEC
FH
FHC
FP
FVC
GPM
JP
PB
PIV
PSI
TS
FIRE PROTECTION LEGEND
FIRE PROTECTION WATER
PRE-ACTION
FIRE SPRINKLER
WET STANDPIPE
ALARM VALVE
DRY-PIPE VALVE
PRE-ACTION VALVE
FIRE HYDRANT
SECTIONAL VALVE
ANGLE VALVE WITH DRAIN
OS AND Y
OS AND Y WITH TAMPER SWITCH
POST INDICATOR VALVE
ALARM CHECK VALVE
CHECK VALVE
VALVE WITH TAMPER DETECTION
FREE STANDING TEST HEADER
WALL MOUNTED TEST HEADER
FIRE DEPARTMENT CONNECTION
FREE STANDING SIAMESE
FIRE DEPARTMENT CONNECTION
SIAMESE
FLOW ALARM
FULLY SPRINKLERED SPACE
FIRE SYSTEM RISER
FIRE ALARM TRANSMITTER
FIRE SYSTEM ANNUNCIATOR
FIRE ALARM COMMUNICATOR
HVAC CONTROL PANEL
BUILDING FIRE CONTROL PANEL
DRY STANDPIPE
FIRE PROTECTION ABBREVIATIONS
DSP
FW
PA
SP
WSP
AS
FTR
FSA
FAC
HVA
FCP
WATER FLOW GPM
.344
.688 1.032
1.376 1.720
2.064 2.408 2.752 3.096 3.440 3.784 4.128 4.472 4.816 5.160 5.504 5.898 6.192 6.536 6.880 7.224 7.568 7.912
8.256 120
45PR
ES
SU
R
E, B ar s
PR
ES
SU
R
E, PS
I
N1.
HYDRAULIC DESIGN DATA
THE WATER FLOW INFORMATION PROVIDED ABOVE IS BASED ON A FLOW TEST PERFORMED
ON 12/04/08, INDICATING A STATIC PRESSURE OF 55 PSI AND A RESIDUAL PRESSURE OF 50
PSI AT 1,030.9 GPM. THE WATER SUPPLY FOR THE FIRE SYSTEM SHALL BE PRESSURIZED BY
A NEW FIRE PUMP. THE FIRE PUMP SHALL BE DESIGNED TO PROVIDE THE FOLLOWING FLOW
CHARACTERISTICS AT THE HMD STANDPIPE OUTLET: RESIDUAL PRESSURE OF 100 PSI AT
250 GPM AT THREE HOSE VALVES (750 GPM TOTAL). THE SYSTEM DESIGN SHALL INCLUDE A
10 PSI SAFETY FACTOR.
DESIGN PARAMETERS
1. THE ENTIRE BUILDING SHALL BE PROTECTED BY A WET PIPE SPRINKLER SYSTEM .
THE FIRE PROTECTION SYSTEM SHALL BE FED FROM AN EXISTING FIRE SYSTEM MAIN
CONNECTED TO THE POST WATER SYSTEM.
2. FOR WATER FLOW DEMAND CALCULATIONS RE: HYDRAULIC DESIGN DATA.
3. THE SYSTEM SHALL BE HYDRAULICALLY CALCULATED FOR THE MOST
HYDRAULICALLY REMOTE AREA.
4. THE WATER FLOW DEMAND SHALL BE AS FOLLOWS:
LIGHT HAZARD:
DESIGN DENSITY: 0.1 GPM / SQUARE FOOT
DESIGN AREA: 3000 SQUARE FEET
HOSE ALLOWANCE: 250 GPM
ORDINARY HAZARD, GROUP 1:
DESIGN DENSITY: 0.15 GPM / SQUARE FOOT
DESIGN AREA: 3000 SQUARE FEET
HOSE ALLOWANCE: 500 GPM
5. THE FOLLOWING APPLICABLE STANDARDS WERE USED TO EVALUATE
THE FIRE PROTECTION REQUIREMENTS:
NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS, LATEST EDITION, 2010.
NFPA 20 INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2010
UFC 3-600-01 DESIGN: FIRE PROTECTION ENGINEERING FOR FACILITIES.
6. FIRE DETECTION AND ANNUNCIATION:
THE FIRE ALARM SYSTEM SHALL HAVE TAMPER VALVE STATUS AND WATER
FLOW TO INDIVIDUAL FIRE PROTECTION ZONES. A FIRE HORN AND
STROBE SHALL BE PROVIDED ON THE EXTERIOR OF THE BUILDING.
RE: THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
200018001600140012001000800600400200
TS
PRESSURE GAUGE
GENERAL NOTES:
1. COORDINATE LOCATION OF ALL ACCESS PANELS, REQUIRED FOR ACCESS TO
THE FIRE PROTECTION SYSTEM, WITH THE ARCHITECTURAL REFLECTED
CEILING PLANS.
2. ALL PRESSURE PIPING IN THE CRAWL SPACE. SHALL BE AS TIGHT TO
STRUCTURE AS PRACTICAL.
6" FIRE SERVICE
6" CHECK VALVE
AND 1/2" BALL VALVE
TO REMOTE FREE STANDING 4-
WAY 6"x2-1/2" FIRE DEPARTMENT
PUMPER CONNECTION. RE: CIVIL
PLANS FOR EXACT LOCATION.
6"
6" SUCTION MAIN
6"
TS TS
6"
6"
6"
TS TS TS
TS
6" 6"
TS 6"
6"
6" FIRE PUMP BY-
PASS
6"
1-1/4"
1-1/4"
FIRST FLOOR
FOURTH FLOOR
PENTHOUSE
SECOND FLOOR
THIRD FLOOR
1-1/4" COMMON
DRAIN RISER
4"
4"
2-1/2" FIRE DEPT. HOSE VALVE WITH
1-1/2" REDUCER AND 1-1/2" CAP AND CHAIN
HOSE THREADS TO MATCH LACKLAND FIRE
DEPT. HOSE LINES (TYP. 16). LOCATE AT
EACH INTERMEDIATE STAIR LANDING.
6"
6" ALARM CHECK VALVE, 2"
MAIN DRAIN VALVE AND PIPING.
DRAIN TO FLOOR DRAIN.
6" CONTROL VALVE
AND TAMPER SWITCH
6" FLOW SWITCH
6"
4"
DRAIN TO STORM.
4" CONTROL
VALVE AND TS
6"
4"6"
6"
TS
STAIR C
STAIR B
6" CONTROL
VALVE AND TS
4"
ROOF
6"
4"
6"
6" CAP
JOCKEY PUMP
4"
4"
4"
STAIR A
6" CONTROL VALVE AND TS
TO PENTHOUSE LEVEL
INTERCONNECTED SYSTEM
6" CAP
6"
6"
6"
6"
4" CAP
STAIR D
4"
4"
4"
2-1/2"
4" CONTROL
VALVE AND TS
4"
4"
4"
4"
4"
1-1/4" COMMON
DRAIN RISER
4" CAP
750 GPM AT 98 PSI ELECTRIC
CASE FIRE PUMP, 60 HP, NOT
TO EXCEED 175 PSI AT CHURN
6" FIRE PUMP TEST HEADER,
WITH (2) 2-1/2" HOSE VALVES
6" DCVA/ BFP
TO FOURTH FLOOR
INTERCONNECTED SYSTEM
TO THIRD FLOOR
INTERCONNECTED SYSTEM
TO SECOND FLOOR
INTERCONNECTED SYSTEM
TO FIRST FLOOR
INTERCONNECTED SYSTEM
FIRST FLOOR
RE: CIVIL FOR CONTINUATION
CRAWL SPACE
4"
4"
4"
4"
4"
4"
4" CAP
6"4"
DC
FIRE PUMP RM
A126
FP-R4-1
JP-R4-16" DOUBLE CHECK
VALVE ASSEMBLY
6" FIRE SERVICE RE: CIVIL
PLANS FOR
CONTINUATION
TO FIRE DEPT. CONNECTION.
COORDINATE EXACT LOCATION
WITH CIVIL PLANS.
FIRE PUMP TEST HEADER
6" FP BELOW REFER TO
A4-P101 AND CIVIL
32681
A
THE SEAL APPEARING ON THIS
P.E. 32681 ON 1 SEPTEMBER 2011
BY KEVIN P. BRESLIN, JR.
DOCUMENT WAS AUTHORIZED
NO
F
ESS
OI N
O R
P
C
I K
E V
OL
ODAR
P. RE
NI
EL
NG
S
N, IL
R E
E
E D
E
IREG
BR
ST
R
J
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
8/
/2
:4 0:
A
M
K E
V
IN
B R
E S
LI
N
R . D
O U
G Y
E S
T E
R
R . D
O U
G Y
E S
T E
R
A4-F001
FI
R
E
PR
O
TE
C
TI
O N
L
EG
EN
D
A N
D N
O
TE
S
SCALE: N.T.S. A4-F001
1FIRE PUMP/ STANDPIPE RISER DIAGRAM
NOTE:
FOR ALL FASTENERS THAT ATTACH TO CONCRETE
SLABS ON LEVELS 2, 3, 4, AND PENTHOUSE, PRIOR
TO DRILLING, DETERMINE LOCATIONS OF POST
TENSIONING STRAND AND PLACE FASTENERS TO
AVOID STRAND.
N
PLAN
NORTH
N
TRUE
NORTH
2' 4'0 1'
SCALE:1/2"=1'-0"
A4-F001
3ENLARGED FIRE PUMP ROOM PLAN
GENERAL FIRE PROTECTION REQUIREMENTS
VERIFICATION: VERIFY ALL DIMENSIONS, ELEVATIONS, SITE CONDITIONS, AND EQUIPMENT PROVIDED BY OTHER TRADES BEFORE STARTING WORK OR PROCURING MECHANICAL EQUIPMENT.
CONFLICTS: IF CONFLICTS SHOULD OCCUR, THE MORE RESTRICTIVE (INCLUDING SPECIFICATIONS) SHALL TAKE PRECEDENCE.
CODES: ALL MATERIALS AND WORK SHALL CONFORM TO THE REQUIREMENTS OF THE IBC 2009, UFC'S AND NFPA CODES.
SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK SHOWN ON DRAWINGS.
PENETRATIONS: PIPES, DUCTS, SLEEVES, CHASES, ETC.: REFER TO CONTRACT SPECIFICATIONS, STRUCTURAL PLANS AND ARCHITECTURAL PLANS FOR REQUIREMENTS.
EXCAVATIONS: LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT, DUCT BANK, OR OTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED.
EQUIPMENT LOADS: MATERIAL LOADS SHALL NOT EXCEED THE ALLOWABLE LOADING FOR THE SUPPORTING MEMBERS AND THEIR CONNECTIONS.
DRAWINGS: THE FIRE PROTECTION DRAWINGS ILLUSTRATE FIRE PROTECTION EQUIPMENT AND DESIGN REQUIREMENTS, REFER TO OTHER DISCIPLINE DRAWINGS FOR NON-FIRE PROTECTION ITEMS WHICH REQUIRE COORDINATION AND SPECIAL PROVISIONS FOR COMPLETE AND OPERATIONAL SYSTEMS.
CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED BUILDING AND DO NOT INDICATE METHODS, PROCEDURES OR
SEQUENCE OF CONSTRUCTION.
DEVIATION: ANY DEVIATION FROM THE APPROVED SET OF MECHANICAL DRAWINGS SHALL ONLY BE MADE AFTER WRITTEN APPROVAL BY THE CONTRACTING OFFICER.
COORDINATION: FIRE PROTECTION PLANS INDICATE ONLY THE APPROXIMATE LOCATION OF ARCHITECTURAL, INTERIOR, FURNISHINGS, ELECTRICAL, MECHANICAL AND OTHER EQUIPMENT, AS WELL AS THE RELATED FIRE PROTECTION REQUIREMENTS NECESSARY TO SUPPORT SUCH EQUIPMENT. THE FINAL POSITIONING OF THESE ITEMS IS DEPENDENT UPON THE EQUIPMENT PROVIDED BY CONTRACTOR IN ACCORDANCE WITH ALL RELEVANT BUILDING CODES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK BETWEEN SUBCONTRACTORS AND CRAFTS IN THIS REGARD, AND PROVIDING NECESSARY SPACE ALLOCATION AND DIMENSIONS IN A TIMELY MANNER TO ALL PARTIES INVOLVED TO ENSURE PROPER COORDINATION.
SCALE: THE DRAWINGS SHALL NOT BE SCALED; REFER TO DIMENSIONING ON THE STRUCTURAL AND ARCHITECTURAL DRAWINGS.
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D
UP
DN
D F HBA G
E
C
SECTION
OFFICER
A101
SECTION
OFFICER
A102
FIRST SGT
A103
COMMANDER'S
OFFICE
A104
CONFERENCE
A105 CHAPLAIN
A106
TOILET
A109
TRAINING
SUPERINTENDENT
A107
BREAK ROOM
A115
MEN
A116
HOLDING
A114
CORRIDOR
A119
CORRIDOR
A120
EQPT
D111
WOMEN
D112
PRT SUPPLY
A110
COMM A1
A121
ELECTRICAL A1
A123
STAIR A1
A122
ENTRY
A100
ORDERLY
A111
MDC
A112
CHARGE OF
QUARTERS
A113
VEST
A117
VEST
A118
CORR
D116
ELEV 1A
A124
ELEV EQUIP
RM
A125MECHANICAL A1
A127
FIRE PUMP RM
A126
COMM
D110
6" FP DOWN TO
CRAWL SPACE
2" DRAIN DN. TO
STORM SEWER.
RE: PLUMBING PLANS.
STANDPIPE, SYSTEM DRAIN
AND VALVE. RE: 1 / A4-
F001
4" FP TO HOSE VALVE AT
INTERMEDIATE STAIR
LANDING. RE: 1 / A4-F001
HOSE VALVE
PROVIDE FREEZE
PROOF HEADS
FOR COMM ROOM
PROVIDE FIRE
PROTECTION SERVICE TO
ELEV. EQUIPMENT RM
FROM CRAWL SPACE
FORMATION AREA
FP-R4-1
JP-R4-1
A4-F001
HOLD OVER
DORMITORY
A108
LIGHT HAZARD
ORDINARY HAZARD GROUP 1
LEGEND
DESIGN PARAMETERS
GENERAL NOTES
1. RE: SHEET A4-P101 FOR FIRE PROTECTION
PIPING IN THE CRAWL SPACE.
1. THE ENTIRE BUILDING SHALL BE PROTECTED BY A
WET PIPE SPRINKLER SYSTEM. PROVIDE OCCUPANCY
COVERAGE AS INDICATED IN THE LEGEND AND BY THE
HATCHING.
2. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS:
A. SPACES WITH LAY-IN OR GYPSUM BOARD
CEILINGS TILE SHALL HAVE QUICK
RESPONSE SPRINKLER HEADS.
B. SPACES WITH EXPOSED STRUCTURE
SHALL HAVE UPRIGHT SPRINKLER HEADS.
3. SPRINKLER HEADS LOCATED IN LAY-IN CEILINGS
SHALL BE PLACED IN THE CENTER OF THE TILE.
COORDINATE THE CEILING TYPES WITH THE
ARCHITECTURAL REFLECTED CEILING PLANS.
32681
A
THE SEAL APPEARING ON THIS
P.E. 32681 ON 1 SEPTEMBER 2011
BY KEVIN P. BRESLIN, JR.
DOCUMENT WAS AUTHORIZED
NO
F
ESS
OI N
O R
P
C
I K
E V
OL
ODAR
P. RE
NI
EL
NG
S
N, IL
R E
E
E D
E
IREG
BR
ST
R
J
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A
KEY PLAN
M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
D C
A B
8/
/2
2:
:5
P
M
K E
V
IN
B R
E S
LI
N
R . D
O U
G Y
E S
T E
R
R . D
O U
G Y
E S
T E
R
A4-F100
G R
O U
N D
F
LO
O R
F
IR
E
PR
O
TE
C
TI
O N
P
LA
N
AR
EA
A
A4-F100
GROUND FLOOR FIRE PROTECTION
PLAN - AREA A
MATCH LINE AREA D
SHEET A4-F103
M
AT
C H
L
IN
E
AR
EA
B
SH
EE
T A4
-F
N
PLAN
NORTH
N
TRUE
NORTH
8'0 4' 16'
SCALE:1/8"=1'-0"
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D
H K L N P QMJ
COMM B1
B121
MECHANICAL B1
B123
STAIR B1
B122
STANDPIPE, SYSTEM
DRAIN AND VALVE
RE: 1 / A4-F001
HOSE VALVE
RE: 1 / A4-
F001
PROVIDE FREEZE
PROOF HEAD
FORMATION AREA
FORMATION AREA
LIGHT HAZARD
ORDINARY HAZARD GROUP 1
LEGEND
DESIGN PARAMETERS
GENERAL NOTES
1. RE: SHEET A4-P101 FOR FIRE PROTECTION
PIPING IN THE CRAWL SPACE.
1. THE ENTIRE BUILDING SHALL BE PROTECTED BY A
WET PIPE SPRINKLER SYSTEM. PROVIDE OCCUPANCY
COVERAGE AS INDICATED IN THE LEGEND AND BY THE
HATCHING.
2. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS:
A. SPACES WITH LAY-IN OR GYPSUM BOARD
CEILINGS TILE SHALL HAVE QUICK
RESPONSE SPRINKLER HEADS.
B. SPACES WITH EXPOSED STRUCTURE
SHALL HAVE UPRIGHT SPRINKLER HEADS.
3. SPRINKLER HEADS LOCATED IN LAY-IN CEILINGS
SHALL BE PLACED IN THE CENTER OF THE TILE.
COORDINATE THE CEILING TYPES WITH THE
ARCHITECTURAL REFLECTED CEILING PLANS.
32681
A
THE SEAL APPEARING ON THIS
P.E. 32681 ON 1 SEPTEMBER 2011
BY KEVIN P. BRESLIN, JR.
DOCUMENT WAS AUTHORIZED
NO
F
ESS
OI N
O R
P
C
I K
E V
OL
ODAR
P. RE
NI
EL
NG
S
N, IL
R E
E
E D
E
IREG
BR
ST
R
J
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A
KEY PLAN
M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
D C
A B
8/
/2
2:
:5
P
M
K E
V
IN
B R
E S
LI
N
R . D
O U
G Y
E S
T E
R
R . D
O U
G Y
E S
T E
R
A4-F101
G R
O U
N D
F
LO
O R
F
IR
E
PR
O
TE
C
TI
O N
P
LA
N
AR
EA
B
A4-F101
GROUND FLOOR FIRE PROTECTION
PLAN - AREA B
MATCH LINE AREA C
SHEET A4- F102
M
AT
C H
L
IN
E
AR
EA
A
SH
EE
T A4
-F
8'0 4' 16'
SCALE:1/8"=1'-0"
N
PLAN
NORTH
N
TRUE
NORTH
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D
H K L N P QMJ
VENDING
C123
STAIR C1
C122
COMM C1
C124
4" FIRE PROTECTION
SYSTEM DRAIN DOWN,
RE: A4-P101 FOR
CONTINUATION
PROVIDE FREEZE
PROOF HEAD
STANDPIPE, SYSTEM
DRAIN AND VALVE
RE: 1 / A4-F001
HOSE VALVE
FORMATION AREA
FORMATION AREA
4" FP
LIGHT HAZARD
ORDINARY HAZARD GROUP 1
LEGEND
DESIGN PARAMETERS
GENERAL NOTES
1. RE: SHEET A4-P101 FOR FIRE PROTECTION
PIPING IN THE CRAWL SPACE.
1. THE ENTIRE BUILDING SHALL BE PROTECTED BY A
WET PIPE SPRINKLER SYSTEM. PROVIDE OCCUPANCY
COVERAGE AS INDICATED IN THE LEGEND AND BY THE
HATCHING.
2. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS:
A. SPACES WITH LAY-IN OR GYPSUM BOARD
CEILINGS TILE SHALL HAVE QUICK
RESPONSE SPRINKLER HEADS.
B. SPACES WITH EXPOSED STRUCTURE
SHALL HAVE UPRIGHT SPRINKLER HEADS.
3. SPRINKLER HEADS LOCATED IN LAY-IN CEILINGS
SHALL BE PLACED IN THE CENTER OF THE TILE.
COORDINATE THE CEILING TYPES WITH THE
ARCHITECTURAL REFLECTED CEILING PLANS.
32681
A
THE SEAL APPEARING ON THIS
P.E. 32681 ON 1 SEPTEMBER 2011
BY KEVIN P. BRESLIN, JR.
DOCUMENT WAS AUTHORIZED
NO
F
ESS
OI N
O R
P
C
I K
E V
OL
ODAR
P. RE
NI
EL
NG
S
N, IL
R E
E
E D
E
IREG
BR
ST
R
J
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A
KEY PLAN
M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
D C
A B
8/
/2
2:
:2
P
M
K E
V
IN
B R
E S
LI
N
R . D
O U
G Y
E S
T E
R
R . D
O U
G Y
E S
T E
R
A4-F102
G R
O U
N D
F
LO
O R
F
IR
E
PR
O
TE
C
TI
O N
P
LA
N
AR
EA
C
A4-F102
GROUND FLOOR FIRE PROTECTION
PLAN - AREA C
N
PLAN
NORTH
N
TRUE
NORTH
8'0 4' 16'
SCALE:1/8"=1'-0"
M
AT
C H
L
IN
E
AR
EA
D
SH
EE
T A4
-F
MATCH LINE AREA B
SHEET A4-F101
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D
D F HBA G
E
C
SECTION
OFFICER
D100
SECTION
OFFICER
D101
JANITOR
D106
HOLD OVER
DORMITORY
D107
TOILET
D108
SUPPLY
STORAGE
D109
EQPT
D111
WOMEN
D112
PRT SUPPLY
A110
CORRIDOR
D115
MECHANICAL D1
D123
COMM D1
D121
STAIR D1
D122
ENTRY
A100
CHARGE OF
QUARTERS
A113
MULTI-FUNCTION/TRAINING
OFFICE
D102
WOMEN STAFF
D103
MEN STAFF
D104
VEST
D113
VEST
D114
CORR
D116
CORRIDOR
D117
MEN SHOWER
D105
COMM
D110
PROVIDE FREEZE
PROOF HEAD
HOSE VALVE AT
INTERMEDIATE
STAIR LANDING
STANDPIPE,
SYSTEMDRAIN AND
VALVE RE: 1 / A4-
F001
FORMATION AREA
LIGHT HAZARD
ORDINARY HAZARD GROUP 1
LEGEND
DESIGN PARAMETERS
GENERAL NOTES
1. RE: SHEET A4-P101 FOR FIRE PROTECTION
PIPING IN THE CRAWL SPACE.
1. THE ENTIRE BUILDING SHALL BE PROTECTED BY A
WET PIPE SPRINKLER SYSTEM. PROVIDE OCCUPANCY
COVERAGE AS INDICATED IN THE LEGEND AND BY THE
HATCHING.
2. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS:
A. SPACES WITH LAY-IN OR GYPSUM BOARD
CEILINGS TILE SHALL HAVE QUICK
RESPONSE SPRINKLER HEADS.
B. SPACES WITH EXPOSED STRUCTURE
SHALL HAVE UPRIGHT SPRINKLER HEADS.
3. SPRINKLER HEADS LOCATED IN LAY-IN CEILINGS
SHALL BE PLACED IN THE CENTER OF THE TILE.
COORDINATE THE CEILING TYPES WITH THE
ARCHITECTURAL REFLECTED CEILING PLANS.
32681
A
THE SEAL APPEARING ON THIS
P.E. 32681 ON 1 SEPTEMBER 2011
BY KEVIN P. BRESLIN, JR.
DOCUMENT WAS AUTHORIZED
NO
F
ESS
OI N
O R
P
C
I K
E V
OL
ODAR
P. RE
NI
EL
NG
S
N, IL
R E
E
E D
E
IREG
BR
ST
R
J
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A
KEY PLAN
M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
D C
A B
8/
/2
2:
:2
P
M
K E
V
IN
B R
E S
LI
N
R . D
O U
G Y
E S
T E
R
R . D
O U
G Y
E S
T E
R
A4-F103
G R
O U
N D
F
LO
O R
F
IR
E
PR
O
TE
C
TI
O N
P
LA
N
AR
EA
D
A4-F103
GROUND FLOOR FIRE PROTECTION
PLAN - AREA D
8'0 4' 16'
SCALE:1/8"=1'-0"
N
PLAN
NORTH
N
TRUE
NORTH
MATCH LINE AREA A
SHEET A4-F100
M
AT
C H
L
IN
E
AR
EA
C
SH
EE
T A4
-F
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D
D F HBA G
E
C
DORM 2A1
A201
SHOWER 2A1
A202
WC 2A1
A204
LAUNDRY 2A1
A205
LUGGAGE 2A1
A206
DAYROOM 2A1
A207
OFFICE 2A1
A208
STORAGE
A209
MECH 2A
A210
COMM 2A
A211
DAYROOM 2A2
A212
OFFICE 2A2
A213 LAUNDRY 2A2
A214
LUGGAGE 2A2
A215
WC 2A2
A216
SHOWER 2A2
A218
DORM 2A2
A219
CORRIDOR 2A
A221
STAIR 2A
A222
CORRIDOR 2A
A223
ELEV 2A
A224
CORRIDOR 2A
A225
CORRIDOR 2A
A227
CORRIDOR 2A
A220
CORRIDOR 2A
A226
CORRIDOR 2A
A228
ENTRY 2A1
A203
ENTRY 2A2
A217
ELEC 2A
A210A
HOSE VALVE
SPRINKLER ZONE
RISER AND SYSTEM
DRAIN
STANDPIPE
LIGHT HAZARD
ORDINARY HAZARD GROUP 1
LEGEND
DESIGN PARAMETERS
1. THE ENTIRE BUILDING SHALL BE PROTECTED BY A
WET PIPE SPRINKLER SYSTEM. PROVIDE
OCCUPANCY COVERAGE AS INDICATED IN THE
LEGEND AND BY THE HATCHING.
2. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS:
A. SPACES WITH LAY-IN OR GYPSUM BOARD
CEILINGS TILE SHALL HAVE QUICK
RESPONSE SPRINKLER HEADS.
B. SPACES WITH EXPOSED STRUCTURE
SHALL HAVE UPRIGHT PENDANT HEADS.
3. SPRINKLER HEADS LOCATED IN LAY-IN CEILINGS
SHALL BE PLACED IN THE CENTER OF THE TILE.
COORDINATE THE CEILING TYPES WITH THE
ARCHITECTURAL REFLECTED CEILING PLAN.
ROOM NUMBER LEGEND
D201
BUILDING QUADRANT
FLOOR LEVEL
ROOM NUMBER
NOTE: ROOM NUMBERS ON 2ND, 3RD AND 4TH
FLOOR ARE THE SAME EXCEPT FOR FLOOR LEVEL
32681
A
THE SEAL APPEARING ON THIS
P.E. 32681 ON 1 SEPTEMBER 2011
BY KEVIN P. BRESLIN, JR.
DOCUMENT WAS AUTHORIZED
NO
F
ESS
OI N
O R
P
C
I K
E V
OL
ODAR
P. RE
NI
EL
NG
S
N, IL
R E
E
E D
E
IREG
BR
ST
R
J
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt ed b y:
E N
G
IN
E E
R
D at e:
S ol
N o.
C on tr N o.
R ev
P lo t s ca le
P lo t d at e:
Fi le n am e:
C on tr N o.
D E
S
IG
N F
IL
E
Fort Worth District
US Army Corps of Engineers
1:
D A
V
ID
L U
K E
, P E of
LA
C
K
LA
N D
A
FB
, T E
X A
S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
E A
S T
C A
M P
U S
A
IR
M E
N T
R A
IN
IN
G C
O M
P
LE
X
(A
TC
4)
X X
X X
X
P lo t D at e H er e
S E
P
TE
M B
E R
1 2 3 4 5
D
C
B
A
KEY PLAN
M P
LS
R
D R
A W
IN
G
N U
M B
E R
: L A
1 -
X X
X X
X X
X
D
C
B
A
1 2 3 4 5
W
G
-1 1-
R -0
D C
A B
8/
/2
2:
:3
P
M
K E
V
IN
B R
E S
LI
N
R . D
O U
G Y
E S
T E
R
R . D
O U
G Y
E S
T E
R
A4-F104
SE
C
O N
D T
H R
O U
G H
F O
U R
TH
F
LO
O
R F
IR
E
PR
O
TE
C
TI
O
N P
LA
N
AR
EA
A
A4-F104
SECOND THROUGH FOURTH FLOOR
FIRE PROTECTION PLAN - AREA A
N
PLAN
NORTH
N
TRUE
NORTH
8'0 4' 16'
SCALE:1/8"=1'-0"
M
AT
C
H L
IN
E
AR
EA
B
SH
EE
T
A4 -F
MATCH LINE AREA D
SHEET A4-F107
N o.
D es cr ip tio n
D .O
.N o.
A ct io n
D
DNUP
H
K L N P QMJ
DORM 2B2
B219
SHOWER 2B2
B218
ENTRY 2B2
B217
WC 2B2
B216
LAUNDRY 2B2
B214
LUGGAGE 2B2
B215
OFFICE 2B2
B213
DAYROOM 2B2
B212
COMM 2B
B211
MECH 2B
B210
STORAGE
B209
OFFICE 2B1
B208
DAYROOM 2B1
B207
LUGGAGE 2B1
B206 LAUNDRY 2B1
B205
WC 2B1
B204
SHOWER 2B1
B202
DORM 2B1
B201
CORRIDOR 2B
B221
STAIR 2B
B222
CORRIDOR 2B
B223
CORRIDOR 2B
B225
CORRIDOR 2B
B227
CORRIDOR 2B
B226
CORRIDOR 2B
B228
SHAFT
B224
ENTRY 2B1
B203
ELEC 2B
B210A
HOSE VALVE
STANDPIPE AND
SYSTEM DRAIN
CORRIDOR 2B
B220
LIGHT HAZARD
ORDINARY HAZARD GROUP 1
LEGEND
DESIGN PARAMETERS
1. THE ENTIRE BUILDING SHALL BE PROTECTED BY A
WET PIPE SPRINKLER SYSTEM. PROVIDE
OCCUPANCY COVERAGE AS INDICATED IN THE
LEGEND AND BY THE HATCHING.
2. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS:
A. SPACES WITH LAY-IN OR GYPSUM BOARD
CEILINGS TILE SHALL HAVE QUICK
RESPONSE SPRINKLER HEADS.
B. SPACES WITH EXPOSED STRUCTURE
SHALL HAVE UPRIGHT PENDANT HEADS.
3. SPRINKLER HEADS LOCATED IN LAY-IN CEILINGS
SHALL BE PLACED IN THE CENTER OF THE TILE.
COORDINATE THE CEILING TYPES WITH THE
ARCHITECTURAL REFLECTED CEILING PLAN.
ROOM NUMBER LEGEND
D201
BUILDING QUADRANT
FLOOR LEVEL
ROOM NUMBER
NOTE: ROOM NUMBERS ON 2ND, 3RD AND 4TH
FLOOR ARE THE SAME EXCEPT FOR FLOOR LEVEL
32681
A
THE SEAL APPEARING ON THIS
P.E. 32681 ON 1 SEPTEMBER 2011
BY KEVIN P. BRESLIN, JR.
DOCUMENT WAS AUTHORIZED
NO
F
ESS
OI N
O R
P
C
I K
E V
OL
ODAR
P. RE
NI
EL
NG
S
N, IL
R E
E
E D
E
IREG
BR
ST
R
J
Sheet reference number
Sheet
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
TR
IC
T, C O
R P
S O
F E
N G
IN
E
E R
S
FO
R T
W O
R
TH
, T E
X A
S
D es ig ne d by
D w n by
R ev ie w ed b y:
S ub m itt…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .