Fort Jackson Generator List 2026.xls
XLS spreadsheet 47 KB Posted
- Attached to
- OmniMetrix Cellular Generator Monitors
- Solicitation number
- W9124C27QA005
About this file
This file is a generator inventory list for Fort Jackson documenting 13 generator units deployed across the installation. The inventory includes detailed specifications for each generator, including building numbers serviced, specific locations, engine manufacturers and model numbers, genset manufacturers and model numbers, fuel type, output capacity (ranging from 7 kW to 400 kW), engine horsepower, manufacture dates, monitoring equipment serial numbers, and controller types. Notable generators include a 400 kW Cummins diesel unit at Building 2400, a 180 kW natural gas Cummins unit at Building 5499 servicing the EMS/Fire Department, and a 275 kW MTU diesel unit at Building 7533 supporting the Emergency Operations Center. Multiple units are equipped with Omnimetrix cellular monitors and Basler or Generac controllers, with monitoring serial numbers recorded for tracking purposes.
This inventory appears to support the related RFQ W9124C27QA005 issued by the Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood for OmniMetrix Cellular Generator Monitors. The solicitation, set-aside for 100% Total Small Business, requires quotes for generator monitoring services by 10:00 AM on November 20, 2026, with vendor questions due by 10:00 AM on November 9, 2026. The inventory list provides the baseline data on existing generator assets at Fort Jackson that would require monitoring services under the contract.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fort Jackson Generators
| Building Number | Serviced By | Specific Location | Building Function | Engine Manufacturer | Engine Model Number | Engine Serial Number | Genset Manufacturer | Genset Model Number | Genset Serial Number | Fuel | Generator Output (kW) | Engine HP | Manufacture Date | Omnimetrix Monitor Serial Number | Unit ID | Model | Controller Type |
| 2400 | DPW | Behind building | Headquarters | Cummins | TD400-01 | P-8376 | Diesel | 400 | 536 | Jun-15 | 59576 | Basler DGC 2020 | |||||
| 2609 | DPW | Behind building, inside fence | NEC | Mitsubishi | 4D34-T(?) | Unknown | Generac | 3931290100 | 2076879 | Diesel | 60 | 80 | Apr-04 | 66272 | Basler DGC 2020 | ||
| 3100 | DPW | Next to building, inside fence | NEC | Cummins | Unknown | Unknown | Cummins | DSFAE-7295859 | F110221737 | Diesel | 80 | 107 | Jun-11 | 7876785926 | 59575 | TG PRO-LTE-BASE | Cummins PCC 2100 Hardwire |
| J4236 | DPW | Next to building, inside fence | NEC | Mitsubishi | 4D34-T | 0D5825 | Generac | 3617980100 | 2074860 | Diesel | 80 | 107 | Nov-03 | 48403 | Basic Controller - Hardwire Only | ||
| 4282 | DPW | Behind building | NEC | Cummins | Q5X15-G9 | 79635574 | Cummins | DFEH-1220445 | A130452520 | Diesel | 354 | 475? | Jan-13 | 48400 | Cummins PCC 2100 Hardwire | ||
| 5499 | DPW | N/A | EMS/Fire Department | Cummins | GTA855C1 | 25273798 | Elliot Power Systems | 180RN | BX01J193 | Natural Gas | 180 | 293 | Nov-01 | 59572 | Special - Custom Application | ||
| 5615 | DPW | Behind building, inside fence | NEC | Cummins | QSM11-G4NR3 | 2003245 | Cummins | DQHAB-8086897 | J110256725 | Diesel | 300 | 402 | Sep-11 | 48401 | Cummins PCC 2100 Hardwire | ||
| 12020 | DPW | N/A | NEC | Cummins | Unknown | Unknown | Cummins | DSFAE-7295845 | F110221739 | Diesel | 80 | 107 | Jun-11 | 48402 | Basic Controller - Hardwire Only | ||
| JRR | DPW | Johnson Rifle Road | NEC | Unknown | Unknown | Generac | 14861230100 | 2118091 | Diesel | 50 | 67 | Dec-16 | 48404 | Generac H Panel | |||
| 7533 | DPW | N/A | Emergency Operations Center (EOC) | MTU | 6R1600G70S | 16301001230 | MTU/Marathon Electric | 433PSL6216 | MX159004 PH | Diesel | 275 | 369 | 2010 | 59574 | Basler DGC 2020 | ||
| F7905 | LRC | Inside fence | Range Control | Unknown | Unknown | TN4T00175 | Generac | 12700960100 | 2109064 | Diesel | 7 | 51 | Jan-11 | 66271 | Generac H Panel | ||
| Gate 4 | DES | N/A | N/A | John Deere | Unknown | PE4024R011093 | Generac | 10648970200 | 2101070 | Diesel | 30 | 40 | Nov-09 | 59573 | Generac H Panel | ||
| Gate 5 | DES | N/A | N/A | John Deere | Unknown | PE4024R007046 | Generac | 10648970200 | 2101071 | Diesel | 30 | 40 | Jan-09 | ? | ? | ||
| Green highlight means calculated horsepower based on kilowatt using the equation: kW x 1.341 = hp. |
&CAppendix A Generator Inventory
File details come from the government source that posted it. Updated .