B08 W9123822R0009 UTTR464-3_M501.pdf
PDF 163 KB Posted
- Solicitation number
- W9123822R0009
About this file
This solicitation is for design-bid-build construction services to build nine earth-covered modular storage magazines at the Utah Test and Training Range in Utah. The U.S. Army Corps of Engineers, Sacramento District, will require construction of magazines sized according to the Modified Standard Navy Modular Storage Magazine design for staging D5 missile motors. Each magazine must include a mechanical room and an elevated concrete dock and floor with an air-pallet-bearing floor finish. The magazines will be located within the existing munitions storage area security perimeter. Supporting facilities include special foundations, paving, antiterrorism/force protection features, electrical utilities, and mechanical utilities. The project will comply with AT/FP regulations and physical security mitigation per DoD standards. Special inspections will be required per UFC criteria, and facility evaluation tests must be completed during and after construction to verify compliance with design documents. The solicitation and attachments provide additional information.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S
PI
VALVE (1/4")
SOLENOID - 3 WAY
TO PNEUMATIC DOOR SEALS
3-WAY
AIR COMPRESSOR
VACUUM EDUCTOR
HPS
1/2" (MANUAL BLEED)
BALL VALVE (TYP.)
VALVE (1/2")
FROM DOOR LIMIT SWITCH
& PUSH BUTTON STATION
CONTROLS
AIR RECEIVER
MANUAL SHUT-OFF
VALVE
(AIR RECEIVER)
PI
TAG ON CHAIN: "MANUAL BLEED"
TAG ON CHAIN:
"MANUAL SHUT-OFF"
PSV
TAG ON CHAIN: "3-WAY VALVE"
TAG ON CHAIN:
"2-WAY VALVE"
2-WAY SOLENOID
TAG ON CHAIN:
"TO EDUCTOR"
TO VENT
TO DRAIN
AUTOMATIC DRAIN
VALVE
FILTER
DRYER
1/2"
1/2"
1/2"
HIGH PRESSURE SWITCH
PRESSURE SAFETY VALVE
PRESSURE INDICATOR
LPS LOW PRESSURE SWITCH
PRESSURE REGULATOR
ADJUSTABLE AIR
NOTES:
1. THE THREE-WAY SOLENOID VALVE SHALL ALLOW COMPRESSED AIR TO PRESSURIZE THE
DOOR SEAL TO CLOSE DOOR AIR-TIGHT.
2. THE THREE-WAY SOLENOID VALVE SHALL EVACUATE AIR FROM DOOR SEAL THROUGH THE
VACUUM EDUCTOR BEFORE THE DOOR OPENS. THE SOLENOID VALVE SHALL REMAIN
OPEN EXACTLY 2 MINUTES.
3. FOR SEQUENCE OF OPERATION AND COMPRESSOR SYSTEM REQUIREMENTS, SEE
SPECIFICATION SECTION 08 39 53.
4. THREE WAY SOLENOID VALVE SHALL REMAIN IN LAST POSITION WHEN POWER IS LOST AND
SHALL BE CAPABLE OF MANUAL OVERRIDE.
5. WHEN MANUAL BLEED VALVE IS MANUALLY OPENED, THE AIR RECEIVER MANUAL SHUT-OFF
VALVE SHALL BE CLOSED.
6. MOUNT 8 1/2"x11" LAMINATED PLASTIC SIGN ON OR ABOVE BLAST DOOR CONTROL PANEL
WITH THE FOLLOWING INSTRUCTIONS (WITH MODIFICATIONS TO INSTRUCTIONS TO BE
COORDINATED WITH THE COR):
• TO MANUALLY DEFLATE DOOR SEALS WITHOUT POWER,
A. CLOSE AIR RECEIVER MANUAL SHUT-OFF VALVE.
B. OPEN MANUAL BLEED VALVE & CLOSE WHEN PRESSURE IS ATMOSPHERIC.
C. OPEN 3-WAY SOLENOID VALVE TO EDUCTOR.
D. OPEN 2-WAY SOLENOID VALVE FOR 30 SECONDS AND CLOSE 2-WAY SOLENOID
VALVE.
• TO MANUALLY INFLATE DOOR SEALS WITHOUT POWER,
A. OPEN 3-WAY SOLENOID VALVE TO COMPRESSOR.
B. OPEN AIR RECEIVER MANUAL SHUT-OFF VALVE.
7. FOR CLARITY, DRIERS, SIGHT GLASSES AND MISCELLANEOUS APPURTENANCES ARE NOT
SHOWN. REFER TO SPECIFICATIONS SECTION 15750 AND 15182 FOR COMPLETE
SPECIFICATIONS OF THE AIR HANDLING SYSTEM AND REFRIGERANT PIPING.
8. PROVIDE THREADED FITTINGS AT COMPRESSED AIR PIPE CONNECTIONS.
1. SUPPORT GAS PIPING FROM STRUCTURE AS REQUIRED. REFER TO
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
GAS-FIRED
EQUIPMENT
NOTES:
4 FT. LONG PROVIDE UNION
IF DRAIN PIPING IS MORE THAN
CAP NO HIGHER THAN
HOLE ON TOP OF
AND DRILL A 1/4"
CAP TOP OF P-TRAP
7"2"4" - 6"
UNION
ON THE DRAIN PAN
THE NIPPLE OR OUTLET
LEAST THE SAME SIZE AS
DRAIN LINE SHALL BE AT
A/C EQUIPMENT
CLEAN OUT PLUG
a b
NOTES:
1. FOR DEPTH OF SEAL
SEE SCHEDULE BELOW
2. LOCATE TRAP SO AS
TO BE ACCESSIBLE
FOR CLEANING.
STATIC PRESSURE ba
1" 2"0" - 1"
2" 3"1" - 2"
2" 4"2" - 3"
REFER TO FLOOR PLANS FOR
CONTINUATION OF PIPING.
BASE RAIL
UNIT TOTAL
DRAIN PAN OUTLET
RS
RL
HAIL GUARD
AIR COOLED
CONDENSING UNIT
PROVIDE REINFORCED
CONCRETE PAD RE:
STRUCTURAL DRAWINGS.
MINIMUM 6"
ABOVE GRADE
TWO-WAY
SIGHT GLASS
LOCKABLE ISOLATION
GATE VALVE
PROVIDE SS FLEXIBLE HOSES
FOR FINAL CONNECTION TO
CONDENSING UNIT
REFRIGERANT LIQUID
AND SUCTION PIPING
NOTE:
1. FINAL QUANTITY AND SIZE OF REFRIGERANT LINES PER MANUFACTURER RECOMMENDATIONS.
2. PROVIDE SEISMIC BRACING PER 23 05 48 19.
PITCH BACK
TO SOURCE
GAS COCK
SEDIMENT TRAP
WITH PLUGGED
TEST CONNECTION
TYPE MAX PIPE
SIZE
SLEEVE
SIZE
SLEEVE SCHEDULE
B 20" 26"
C 18" 24"
D 16" 20"
E 16"12"
G
H
F
4"
3"
6"
6"
5"
10"
I 1 1/2" 3"
EQ. EQ.
EQ.EQ.EQ.
A 24" 30"
CONCRETE OR
MASONRY WALL.
SCHED. 40 STEEL
PIPE SLEEVE GALV.
AFTER MANUF.
MODULAR COMPRESSION
SEALS EACH SIDE OF
WALL
NOTES:
1. SCHED.40 STEEL PIPE SLEEVE
SHALL BE HOT DIPPED
GALVANIZED AFTER
FABRICATION.
SCHED. 40 STEEL
PIPE SUPPLY OR
RETURN. PIPE
SIZE AS SHOWN
IN PLAN
3" HIGH STEEL
FLANGES CONT.
WELDED TO PIPE
SLEEVE. SLEEVE
SHALL HAVE 2
FLANGES ON PIPE
SIZES 16" AND
ABOVE.
2. PROVIDE COMPRESSION SEAL
FASTENERS WITH CAPTURE
DEVICE TO HOLD NUTS IN
PLACE WHILE TIGHTENING
NOTE 2
1"1/2"0 2"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C A
P
IT
A L P
R O
J E
C T
N O
K S
R M
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
D M
IS
S
IL
E
M O
T O
R R
E C
E
IP
T /S
T O
R A
G E
F A
C
IL
IT
Y
U T
A H
T E
S T
T
R A
IN
IN
G R
A N
G E
U T
A H
READY TO ADVERTISE
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
-2
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
A N
U A
R Y
K S
R M
O
P T
IO
N
A L
M O
T O
R S
T O
R A
G E
M
A G
A Z
IN
E
S
SHEET OF 147
IS
S
U E
D A
T E
M-501
UTTR464-3
M E
C H
A N
IC
A
L
A O
R T
O N
A O
R T
O N
H L
IU
B P
E R
L B
E R
G
D E
T A
IL
S
SCALE: NO SCALED4
GAS APPLIANCE CONNECTION DETAIL
SCALE: NO SCALED7
CONDENSATE DRAIN TRAP
SCALE: NO SCALED1
MODULAR COMPRESSION SEAL DETAIL
SCALE: NO SCALEA5
COMPRESSED AIR FLOW DIAGRAM
12" = 1'-0"A1
CONDENSING UNIT INSTALLATION DETAIL
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/0
/2
| Sheets |
| M-501 - DETAILS |
File details come from the government source that posted it. Updated .