B08 W9123822R0009 Attachment 2 Design dated 19 January 2022 _Part3.pdf

PDF 35 MB Posted

Attached to
DBB, Utah Test and Training Range (UTTR) Modular Storage Magazines (MSMs) Federal contract opportunity
Solicitation number
W9123822R0009
Issued by
Department of the Army Corps of Engineers Engineering District Sacramento

About this file

This document outlines a federal contract solicitation for design-bid-build construction services. The U.S. Army Corps of Engineers, Sacramento District, is seeking to construct nine earth-covered Modular Storage Magazines at the Utah Test and Training Range in Utah for staging D5 missile motors. Each magazine must include a mechanical room, elevated concrete dock and floor, and air-pallet-bearing floor finish. They will be located within the existing munitions storage area security perimeter. Supporting facilities include special foundations, paving, antiterrorism/force-protection features, electrical and mechanical utilities. Facility Evaluation Tests will be required during and after construction to verify structures comply with design criteria. The solicitation and attachments provide additional information. Interested parties should review the uploaded solicitation documents for response due dates and other contractual requirements.

View the file

Other files for this federal contract opportunity

Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

01/19/2022

J

CU-XX

48"

GFI

48"

GFI

GFI/

WP

LA#-8

LA#-5

LA#-5

ESM-XX

18"

AIR

BEARING

MOTOR

STORAGE

MECHANICAL

ROOM

E-401

A1

HA#-13,15,17

WP

M

3BLAST DOOR

CONTROL PANEL

IDS PANEL

LA#-21

IDS-MX

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G E

M

A G

A Z

IN

E

S

SHEET OF

E-101

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

P O

W E

R P

L A

N

1/8" = 1'-0"A1

POWER PLAN

1. COORDINATE FINAL LOCATION OF ELECTRICAL EQUIPMENT AND COMPONENTS

WITH OTHER TRADES PRIOR TO ROUGH-IN.

2. REFER TO THE ONE-LINE RISER DIAGRAMS ON SHEET E601 AND E602 FOR

ADDITIONAL INFORMATION.

3. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATION OF

MECHANICAL AND PLUMBING EQUIPMENT. REFER TO THE MECHANICAL EQUIPMENT

CONNECTION SCHEDULE ON SHEET E602 FOR POWER SOURCE AND ADDITIONAL

INFORMATION.

4. REFER TO FIRE ALARM DRAWINGS FOR EXACT LOCATION OF FIRE ALARM

EQUIPMENT.

5. REFER TO PANEL SCHEDULES ON SHEET E603 FOR CIRCUIT INFORMATION.

6. REFER TO TELECOMMUNICATION DRAWINGS FOR EXACT LOCATION OF

TELECOMMUNICATION EQUIPMENT REQUIRING POWER.

7. ALL CONDUIT SHALL BE RGS CONDUIT UNLESS INDICATED OTHERWISE.

8. DO NOT ROUTE EXPOSED CONDUITS ON EXTERIOR WALLS.

9. ALL ELECTRICAL/COMMUNICATION'S EQUIPMENT/DEVICES/BOXES MOUNTED ON

EXTERIOR WALLS SHALL BE PAINTED TO MATCH THE WALL SURFACE COLOR.

10. PAINT METAL ENCLOSURE OF EQUIPMENT TO MATCH THE PAINTED WALL COLOR.

GENERAL SHEET NOTES

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

SHEET KEYNOTES

1 PROVIDE A PUSH BUTTON DOOR CONTROL STATION FOR SLIDING DOOR.

COORDINATE WITH SLIDING DOOR PROVIDER.

2 PROVIDE AND INSTALL ALL ASSOCIATED ANCILARRY DEVICES AND

COORDINATE ALL POWER CONNECTION REQUIREMENTS WITH

MANUFACTURER PRIOR COMMENCING WORK. SUBMIT EQUIPMENT DATA

INFORMATION TO ENGINEER FOR REVIEW AND APPROVAL PRIOR

PROCUREMENT.

3 PROVIDE BLAST DOOR CONTROL PANEL. COORDINATE ALL POWER AND

CONTROL RACEWAY REQUIREMENTS WITH MANUFACTURER. PROVIDE

CONTROL WIRING FOR INTERLOCKS WITH DOOR LIMIT SWITCHES,

COMPRESSED AIR SEALS, AND MECHANICAL BYPASS FOR DOOR OPERATION.

PC

ON ROOF

FACING NORTH

RE: B8/E-502

HA#:8

A a

HA#:9

C

HA#:9

C

HA#:7

D b

HA#:9

C

HA#:7

D b

HA#:9

C

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

A a

HA#:8

B

HA#:8

B

ROUTED VIA

CONTACTOR.

RE: B8/E-502

(TYP)

MECHANICAL

ROOM

AIR

BEARING

MOTOR

STORAGE

ab

HA#:8

B

MOUNTED

AT 9'-0" A.F.F

TO BOTTOM

OF FIXTURE

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-102

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

L

IG

H T

IN

G

P L

A N

1/8" = 1'-0"A1

LIGHTING PLAN

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL SHEET NOTES

1. COORDINATE FINAL LOCATIONS OF ALL LIGHTING FIXTURES AND ASSOCIATED

LIGHTING CONTROLS WITH OTHER TRADES PRIOR TO ROUGH-IN.

2. ALL CONDUIT SHALL BE RGS CONDUIT UNLESS INDICATED OTHERWISE.

3. LIGHTING FIXTURES IN ROOM 101 SHALL BE MOUNTED WITH STEM HANGERS WITHIN

THE ROOF PANEL POCKET AND FLUSH WITH BOTTOM OF POCKET.

4. REFER TO THE DETAILS ON SHEET E-505 FOR ADDITIONAL INFORMATION.

5. ALL TYPE 'A' FIXTURES WILL BE MOUNTED AT 14'-6" A.F.F. TO BOTTOM OF FIXTURE.

6. ALL TYPE 'B' FIXTURES WILL BE MOUNTED AT 7'-8" A.F.F. TO BOTTOM OF FIXTURE.

7. ALL TYPE 'C' & 'D' FIXTURES WILL BE MOUNTED AT 16'-0" A.F.F. TO BOTTOM OF FIXTURE.

8. DO NOT ROUTE EXPOSED CONDUITS ON EXTERIOR WALLS.

9. ALL ELECTRICAL/COMMUNICATION'S EQUIPMENT/DEVICES/BOXES MOUNTED ON

EXTERIOR WALLS SHALL BE PAINTED TO MATCH THE WALL SURFACE COLOR.

10. PAINT METAL ENCLOSURE OF EQUIPMENT TO MATCH THE PAINTED WALL COLOR.

GUARD RAILS

WALL

MOUNTED

ORDNANCE

GROUND

BUS BAR

WALL MOUNTED

ORDNANCE GROUND

BUS BAR (TYP OF 5)

RE: D1/E-501 & F1/E-501

BOND UNDERGROUND

RIGID METAL CONDUIT TO

SECONDARY GROUND

RING WITH #2/0 BARE

COPPER AT ALL

LOCATIONS THAT CONDUIT

CROSSES GROUND RING.

G G G

G G G

G G

G

BOND TO

STRUCTURAL STEEL

(TYP)

GROUND BAR

RE: E7/E-501

TEST WELL

(TYP)

RE: A3/E-502

20' - 0"

MIN (TYP)

GROUND RING

CONDUCTOR

RE: E4/E-501

G G

G G

G G

G G

G

G

REBAR CONNECTION

(TYP) RE: D1/E-504

G G

(TYP)

G G

G G

G

GG

BOND TO HVAC EQUIPMENT WITH #2/0 BARE

COPPER TO GROUND RING.

(TYP)

GUARD RAILS

G

G G

G

GUARD

RAILS

(TYP)

(TYP)

G

ORDNANCE GROUND

TEST POINT

RE: D1/E-502

G

GUARD RAILS 9 10 (TYP)

9 (TYP)

9 10 (TYP)

(TYP)

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-103

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

G R

O U

N D

IN

G

P L

A N

1/8" = 1'-0"A1

LIGHTNING PROTECTION &

GROUNDING PLAN

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

SHEET KEYNOTES

GENERAL SHEET NOTES

1 ROUTE #2/0 BARE COPPER GROUNDING CONDUCTOR (BURIED GROUNDING

RING) AS INDICATED, AT 30" MIN. BELOW FINISHED GRADE AND MINIMUM 3'-0"

FROM FOUNDATION AROUND FACILITY OR AT LEAST 2’-0” FROM THE BUILDING

EXTERIOR DRIP LINE. RE: E4/E-501.

2 FURNISH AND INSTALL ELECTRICAL COPPER GROUNDING BUS. COORDINATE

EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO DETAIL E7, SHEET E-501,

AND DETAIL A1, SHEET E-502.

3 ROUTE #2/0 BARE COPPER GROUNDING CONDUCTOR FROM MAIN GROUND

BUS IN ELECTRICAL ROOM TO SECONDARY GROUNDING RING.

4 ROUTE #2/0 BARE COPPER GROUNDING ELECTRODE FROM REINFORCED

STRUCTURAL STEEL TO SECONDARY GROUNDING RING.

5 ROUTE #2/0 BARE COPPER GROUNDING CONDUCTOR FROM FOUNDATION

STEEL REBAR TO SECONDARY GROUND RING.

6 ROUTE #2/0 BARE COPPER GROUNDING CONDUCTOR BETWEEN UPPER AND

LOWER GUARD RAILS AND SECURE TO HEADWALL.

7 PROVIDE #2/0 INSULATED COPPER GROUNDING CONDUCTOR IN 1” PVC

CONDUIT FROM ORDNANCE GROUND TO GROUND TEST WELL AS INDICATED

UTILIZING BOLTED CONNECTIONS FOR EASE IN DISCONNECTING DURING

TESTING. INSULATION SHALL BE STRIPPED BARE FROM TERMINATION POINT

UP TO THE POINT OF CONCEALMENT IN CONDUIT. PERFORM TESTING PER

NAVSEA OP5. REFER TO TEST PLAN IN SPECIFICATIONS.

8 PROVIDE ORDNANCE GROUND BAR WITH MINIMUM OF THREE POINT

CONNECTION FOR FS/SS MOTORS. RE: F1/E-501 & D1/E-501.

9 ALL HEADWALL GUARD RAILS AND ALL ASSOCIATED POSTS SHALL BE DRILLED

AND TAPPED WITH THREADED STUDS FOR CONNECTION TO COPPER

GROUNDING CONDUCTORS WITH #2/0 COPPER WIRE LUGS. ROUTE #2/0 BARE

COPPER GROUNDING CONDUCTOR EXPOSED ALONG THE ENTIRE LENGTH OF

HEADWALL. PROVIDE BIMETALLIC CONNECTORS AS REQUIRED FOR

ATTACHING GUARD RAILS TO DOWN GROUNDING CONDUCTORS. ALL

CONNECTORS, DEVICES AND COMPONENTS UTILIZED SHALL BE EITHER UL

LISTED OR LABELED AND LISTED FOR ITS USE.

10 GUARD RAILS SHALL BE ALUMINUM PIPE. THICKNESS SHALL NOT BE LESS

THAN 3/16” AND MAXIMUM HEIGHT OF 42” (+/-3”). REFER TO ARCHITECTURAL

DRAWINGS AND ELEVATIONS FOR ADDITIONAL INFORMATION.

11 ROUTE #2/0 BARE COPPER GROUNDING DOWN CONDUCTOR IN A 1" CONDUIT

FROM ROOF SYSTEM TO SECONDARY GROUNDING ELECTRODE. DOWN

CONDUCTOR SHALL BE CONTINOUS AND ON EXTERIOR OF BUILDING.

12 ORDNANCE GROUND BAR AT TRANSPORTER APRON SHALL BE

WALL-MOUNTED ON FACE OF LOADING DOCK AT A MAXIMUM DISTANCE OF

180" FROM THE CENTERLINE MONUMENT.

13 PROVIDE AN ENCLOSURE WITH HINGED DOOR TO ACCOMODATE A

GROUNDING BUS BAR (RE: D1/E-502) FOR TESTING OF THE ORDNANCE

GROUNDING SYSTEM. ENCLOSURE SHALL BE 30" ABOVE FINISHED FLOOR.

PROVIDE LABEL ON DOOR "ORDNANCE GROUND TEST POINT".

14 PROVIDE A #2/0 INSULATED COPPER GROUND IN 1" PVC (SCHEDULE 80)

BETWEEN ORDNANCE GROUND BUS BARS. SURFACE-MOUNTED CONDUIT

SHALL BE ROUTED ON WALL TIGHT TO FLOOR, BELOW ORDNANCE GROUND

BUS BAR. PROVIDE A 3" X 9" BLACK PLASTIC BACKGROUND LABEL WITH 1"

WHITE LETTER INDICATING "ORDNANCE GROUND".

15 PROVIDE A #2/0 INSULATED COPPER GROUND IN 1" PVC (SCHEDULE 80)

BETWEEN ORDNANCE GROUND BUS BARS UNDER SLAB. PROVIDE A 3"X9"

BLACK PLASTIC BACKGROUND LABEL WITH 1" WHITE LETTERS INDICATING

"ORDNANCE GROUND" AT EXPOSED LOCATIONS.

16 BOND THE FIXED EMBEDDED RECEIVERS OF THE REMOVABLE HANDRAIL

SYSTEM. NO BOND REQUIRED TO REMOVABLE HANDRAIL.

17 ENSURE TEST WELL LID COVER LIE OUTSIDE THE EARTH COVERING MOUND.

12. ORDNANCE GROUND BUS BAR SHALL BE COPPER AND UTILIZING A MINIMUM OF

(3) BALL STUD GROUND RECEPTACLES EQUAL TO CROUSE-HINDS CAT#GCT-2

MOUNTED ON COPPER BUS. INSTALL 30" ABOVE FINISHED FLOOR.

10. METAL GUARD RAILS WILL BE CONSTRUCTED AND SERVED AS STRIKE TERMINATION

DEVICES AS PER NFPA 780-11, PARAGRAPH 4.6.1.4. GUARD RAILS SHALL NOT

EXCEED 45" HIGH AND SHALL BE COMPLIANCE WITH OSHA REG. 1926.502 FALL

PROTECTION SYSTEM CRITERIA AND PRACTICES PER 1926.502 (b)(1).

11. PROVIDE A #2/0 BONDING CONDUCTOR FROM SECONDARY GROUND RING TO BLAST

DOOR. EXTEND #6 GROUND CONDUCTOR THROUGH FLEXIBLE CARRIER TRACK.

REFER TO ARCHITECTURAL FOR ADDITIONAL DETAILS.

12. REFER TO A5/E-501 FOR TYPICAL GROUNDING ELECTRODE SYSTEM DIAGRAM.

13. DO NOT ROUTE EXPOSED CONDUITS ON EXTERIOR WALLS.

14. ALL ELECTRICAL/COMMUNICATION'S EQUIPMENT/DEVICES/BOXES MOUNTED ON

EXTERIOR WALLS SHALL BE PAINTED TO MATCH THE WALL SURFACE COLOR.

15. PAINT METAL ENCLOSURE OF EQUIPMENT TO MATCH THE PAINTED WALL COLOR.

16. ALL UNDERGROUND POWER AND COMMUNICATIONS CONDUITS SHALL BE IN

PVC-COATED RIGID METAL CONDUIT WITHIN 50 FEET OF PROTECTED FACILITY AND

FOR AT LEAST 50 FEET PRIOR TO ENTERING PROTECTED FACILITY/AREA. ALL METAL

CONDUIT SHALL BE BONDED TO PRIMARY AND SECONDARY GROUND RINGS AS

APPLICABLE.

17. GROUND TEST WELLS WILL BE INSTALLED OUTSIDE THE LIMITS OF THE EARTH

COVERED MAGAZINE MOUND.

1. THE TERM ‘LIGHTNING PROTECTION SYSTEM’ SHALL BE REFERRED TO AS ‘LPS’

HENCEFORTH.

2. LPS INSTALLATIONS SHALL BE IN COMPLIANCE WITH NFPA 780 AND AFI 32-1065

CRITERIA, AND MANUFACTURED IN ACCORDANCE WITH U.L. 96, IN ACCORDING WITH

NAVSEA OP 5 OR AFMAN 91-201.

3. CONTRACTOR SHALL PROVIDE AN UNDERWRITER’S LABORATORY (UL) LIGHTNING

PROTECTION INSPECTION CERTIFICATE FOR ANY FACILITY HAVING A LPS

INSTALLATION. ADDITIONALLY, A COMMERCIAL THIRD PARTY INSPECTION COMPANY

SHALL CERTIFY THE LPS IS IN COMPLIANCE WITH NFPA 780 AND AFI 32-1065.

4. COMPONENTS INDICATED THIS SHEET ARE SCHEMATIC AND PROVIDE GENERAL

DIRECTION FOR THE LPS COMPONENTS. CONTRACTOR SHALL PROVIDE NECESSARY

COMPONENTS FOR A COMPLETE LPS.

5. PROVIDE #2/0 BARE COPPER GROUND CONDUCTOR AND BOND TO ALL METAL

PARTS, INCLUDING FIXED STAIR HANDRAILS, DOOR AND DOOR FRAMES,

REINFORCEMENT IN FLOOR/WALL, METAL DUCTWORK AND PIPES, AND LOUVERS

LOCATED WITHIN 6' OF A DOWN CONDUCTOR OR AS REQUIRED BY NFPA 780.

6. METAL BODIES WITHIN 6' - 0" OF THE LIGHTNING PROTECTION SYSTEM SHALL BE

BONDED TO THE SYSTEM IN ACCORDANCE WITH UL96A.

7. REFER TO LIGHTNING PROTECTION SYSTEM DETAILS ON SHEET E-502 FOR

ADDITIONAL INFORMATION.

8. PROVIDE FLOOR TO WALL BONDING CONNECTIONS EVERY 4'. RE: A6/E-502.

9. PROVIDE BOND AT EACH CONSTRUCTION JOINT. RE: D6/E-502.

10. WALL, FLOOR, AND ROOF REBAR MATS WILL BE BONDED AS INDICATED IN DETAIL

D1/E-504.

11. ALL GROUNDING CONDUCTORS SHALL BE #2/0 BARE COPPER.

GENERAL SHEET NOTES (CONT.)

T

TA# LA# SPDHA#

EUH-XX

AHU-XX

GFI

LA#-8

DDC

FACU

GFI

LA#-8

LA#-23

COMM CABINET

M

DRAIN VALVE

AC-XX

MOD-XX-E EF-XX

MOD-XX-B

MOD-XX-C

MOD-XX-D

MOD-XX-F

MOD-XX-A

GF-XX

LA#-8

GFI

M

SNOW MELT

CONTROL PANEL

MECHANICAL

ROOM

LIGHTING

CONTACTOR

W / HOA SWITCH

LA#-24

LA#-1

LA#-13

M

M

M

M M

M

M

LA#-2

COMM CABINET

GROUND

BAR

SPD

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-401

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

E N

L A

R G

E D

P O

W E

R P

L A

N

3/4" = 1'-0"A1

ENLARGED POWER PLAN - MECHANICAL

ROOM

1. COORDINATE FINAL LOCATION OF ELECTRICAL EQUIPMENT AND COMPONENTS WITH

OTHER TRADES PRIOR TO ROUGH-IN.

2. REFER TO THE ONE-LINE RISER DIAGRAMS ON SHEET E601 AND E602 FOR

ADDITIONAL INFORMATION.

3. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATION OF

MECHANICAL AND PLUMBING EQUIPMENT. REFER TO THE MECHANICAL EQUIPMENT

CONNECTION SCHEDULE ON SHEET E-602 FOR POWER SOURCE AND ADDITIONAL

INFORMATION.

4. REFER TO FIRE ALARM DRAWINGS FOR EXACT LOCATION OF FIRE ALARM EQUIPMENT.

5. REFER TO PANEL SCHEDULES ON SHEET E602 FOR CIRCUIT INFORMATION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR EXACT LOCATION OF

TELECOMMUNICATION EQUIPMENT REQUIRING POWER.

8. ALL CONDUIT SHALL BE RGS CONDUIT UNLESS INDICATED OTHERWISE.

9. DO NOT ROUTE EXPOSED CONDUITS ON EXTERIOR WALLS.

10. ALL ELECTRICAL/COMMUNICATION'S EQUIPMENT/DEVICES/BOXES MOUNTED ON

EXTERIOR WALLS SHALL BE PAINTED TO MATCH THE WALL SURFACE COLOR.

11. PAINT METAL ENCLOSURE OF EQUIPMENT TO MATCH THE PAINTED WALL COLOR.

GENERAL SHEET NOTES

SHEET KEYNOTES

1 PROVIDE POWER CONNECTION TO HVAC EQUIPMENT. REFER TO E-602

FOR ADDITIONAL INFORMATION OF CIRCUITING AND FEEDER/PROTECTION

DEVICE RATINGS.

GALVANIZED STEEL

STAND-OFF

BRACKET (TYPICAL)

2700V INSULATOR

(TYPICAL)

ELECTROLYTIC COPPER (1/4" x 4")

BUS BAR LENGTH 24".

TWO-HOLE COMPRESSION

LUG GROUND CONNECTION

1 1/8" (TYP.)

1" (TYPICAL)

1/2" DIAMETER

HOLE (TYPICAL)

3/8" DIAMETER HOLE

(TYPICAL)

PROVIDE LABEL INDICATING

USE OF GROUNDING CONDUCTOR

INITIAL BACKFILL PER

SPECIFICATION 31 00 00

EARTHWORK

BACKFILL USING

EXCAVATED MATERIALS

EXISTING

GRADE

M

IN

WARNING TAPE

6" WIDE

6" TOPSOIL

4" MIN.

(TYP.)

4" MIN.

(TYP.)

(T Y

P

IC

A L

3'-0" MIN.

(TYPICAL)

BUILDING

PERIMETER

FOUNDATION

BARE COPPER

COUNTERPOISE.

E4

TYPICAL GROUND RING INSTALLATION DETAIL

SCALE: NO SCALE

A1

ARC FLASH WARNING LABEL

SCALE: NO SCALE

E7

SINGLE POINT GROUNDING BUS (SPGB) BAR DETAIL

SCALE: NO SCALE

A5

GROUNDING ELECTRODE SYSTEM

(TYPICAL FOR EACH MAGAZINE)

SCALE: NO SCALE

2/0 INSULATED GROUND CABLE. 6" MAXIMUM LENGTH EXPOSED

OUTSIDE OF CONDUIT. GROUND CONDUCTOR SHALL BE ROUTED

ABOVE THE FLOOR AND ATTACHED TO THE CONCRETE WALL WITH

CLIP CABLE SUPPORTS. (UNLESS INDICATED OTHERWISE)

2"

1" 1" 6"

18"

22"

11"

LABEL "ORDNANCE GROUND HERE"

1 INCH WHITE LETTERS ON

BLACK PLASTIC BACKGROUND

BRASS GROUND STUD. 2 9/32" OVERALL LENGTH, 1 1/16" THREADED,

3/8-16 NC-2A THREAD. CROUSE-HINDS GCT-2 MOUNTED ON

COPPER BUS BAR. PROVIDE ACCESS HOLE IN 1" PVC PLATE ONLY -

NOT THROUGH 1/4" PVC BACKING PLATE. TYP 3 PLACES

HEX JAM NUT WITH EXT

2 1/8" E-501

D1

TOOTH LOCK WASHER.

COUNTERBORE PVC AS REQD

TYP 2 PLACES.

FLUSH MOUNTED TO WALL.

1" PVC CONDUIT

WALL MOUNTING

HARDWARE

FLAT HEAD COUNTERSINK MACHINE

BOLT (3/8" DIA MAX) WITH

EXTERNAL TOOTH LOCK WASHER.

TYP 2 PLACES.

/4

P

V C

P V

C

/4

C

O P

P E

R

/8

/8

/2

T Y

P

P L

A C

E S

3/4"

BOND PVC PLATES

TOGETHER WITH ADHESIVE

APPROVED FOR USE WITH PVC

F1

WALL MOUNTED ORDNANCE BAR

SCALE: NO SCALE

D1

ORDNANCE GROUND SYSTEM DETAIL

SCALE: NO SCALE

12" MIN.

(TYP.)

NOTES:

1. PROVIDE SELF-ADHESIVE VINYL LABEL TO AFFIX TO ELECTRICAL EQUIPMENT TO WARN OF ARC FLASH HAZARDS.

2. THE LABEL FORMAT AND TEXT CAN BE MODIFIED PROVIDED THAT THE INFORMATION REQUIRED BY

UFC 3-501-01 IS INCLUDED.

3. THE LABEL SHALL BE LOCATED ON THE EQUIPMENT TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE

EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT.

4. THE SIZE OF THE LABEL SHALL BE MINIMUM: EQUIPMENT TYPE HEIGHT WIDTH

INDOOR 2" 3"

OUTDOOR 3" 4.5"

5. A DOWNLOADABLE WINDOWS METAFILE IS AVAILABLE ON THE WHOLE BUILDING DESIGN GUIDE

WEBSITE (WWW.WDBG.ORG) FOR USE IN A LABEL MAKING MACHINE.

A. THE FILE IS LOCATED ON THE "NAVFAC CADD DETAILS" PAGE. TO NAVIGATE TO THIS LOCATION, FOLLOW:

HOME > DOCUMENTS & REFERENCES > CCB > CADD LIBRARY > NAVFAC CADD RESOURCES > NAVFAC CADD DETAILS.

B. ALTERNATIVELY, TYPE IN THE FOLLOWING ADDRESS IN INTERNET EXPLORER: HTTP://WWW.WBDG.ORG/CCB/BROWSE_CAT.PHP?C=232

WIDTH

HEIGHT

REINFORCING

STEEL IN FLOOR

AND WALL (TYP)

LIGHTNING PROTECTION

ALUMINUM GUARD RAILS ON

HEAD WALL

LIGHTNING PROTECTION

ALUMINUM GUARD RAILS

ON HEAD WALL

#2/0 BARE CU GND CONDUCTOR

#2/0 BARE CU

GND CONDUCTOR

GROUND CONNECTION

(TYP)

SECONDARY GROUND RING #2/0

BARE CU GND CONDUCTOR

GROUND TEST WELL WITH

3/4"CU GND ROD; LENGTH

AS REQUIRED.

SECONDARY GROUND

RING #2/0 BARE CU GND

CONDUCTOR

ORDNANCE

GROUND

OG

#2/0 CU GND

CONDUCTOR

IN 1" PVC

CONDUIT

SPGB

MSM PANEL 'HAXX'

G N

#2/0 BARE CU

GND CONDUCTOR

ORDNANCE

GROUND

OG

#4/0

GEC

MAIN DIST.

PANEL 'MDAX'

G N

DOCKING

STATION

G

N

ECG

G

N

TO SERVICE

TRANSFORMER

SERVICE

PANEL 'MPXX'

G

N

PORTABLE

GENERATOR

ECG

ORDNANCE

GROUND

TESTING

POINT

MECHANICAL

EQUIPMENT

SECTION

A. USE STAINLESS STEEL MOUNTING HARDWARE. USE WASHER AND SPLIT LOCK WASHER UNDER

ALL NUTS.

NOTES:

3/4" RADIUS, TYP

1/4" ALUMINUM PLATE, ROUND EDGES; SIZE PER EQUIPMENT REQUIREMENTS

1/2" ALUMINUM PLATE

1/2" RADIUS, TYP

ALUMINUM CHANNEL(4x2.16 IN SEISMIC ZONES 0 AND 1, 6x3.00 IN SEISMIC

ZONES 2 AND HIGHER) LENGTH PER EQUIPMENT REQUIREMENTS

PROVIDE HIGH DENSITY POLYETHYLENE SPACE, MINIMUM THICKNESS 1/16" OR

BITUMASTIC COATING BETWEEN ALUMINUM CONCRETE

NON-SHRINK GROUT

1/2" STAINLESS STEEL CONCRETE ANCHORS OR ANCHOR BOLTS WITH LEVELING

NUTS, (TYP OF 4 EACH BASE)

MINIMUM 12" DIAMETER X 38" DEEP CONCRETE FOOTING. THE FOOTING TO EXTEND

A MINIMUM 4" ABOVE GROUND LEVEL & HAVE A 1/2" SLOPE AWAY FROM THE POST

TO ALLOW FOR DRAINAGE.

12"

TYP

1 1/4", TYP

FOR HEIGHTS EXCEEDING 5'-0" OR WEIGHT OF MOUNTED EQUIPMENT

EXCEEDING 200 LBS, SIZE POSTS AND CONNECTIONS FOR LATERAL

LOADS. EXTEND POSTS TO STRUCTURE ABOVE WHERE REQUIRED BY

CALCULATION, SEE GENERAL ELECTRICAL CONSTRUCTION NOTES.

KEYED NOTES:

3"

M A

X

48" MAX 3"

TYP

3/16

3/16

3/4" CU GND ROD;

LENGTH AS REQUIRED.

B. WHERE EQUIPMENT PAD IS NOT PROVIDED, USE CONCRETE FOOTINGS AS SHOWN.

C4

ELECTRICAL EQUIPMENT SUPPORT DETAIL

SCALE: NO SCALE

PROVIDE 1/2" THREADED INSERTS.

ENSURE ISOLATION FROM REBAR

OR OTHER METALLIC OBJECTS IN WALL.

C. WHERE A LONGER EQUIPMENT RACK IS REQUIRED, PROVIDE ADDITIONAL FOOTINGS/ANCHORS

AT A MAXIMUM SPAN OF 48" O.C. AS INDICATED.

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-501

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

D E

T A

IL

S

2" x 12" x 3/4"

PVC BASE PLATE THICK

1" 3"

12" MIN.

PLAN VIEW

SECTION

MOUNTING

HARDWARE, TYP

1" X 8" X 1/4"

THICK COPPER

BUS BAR

2" X 12" X 1/4"

THICK PVC BACKING

PLATE LAMINATED

TO BASE PLATE

MOUNTING

HARDWARE, TYP

NOTES:

1. PROVIDE A NEMA 3 FIBERGLASS ENCLOSURE WITH HINGED DOOR.

2. SIZE OF COPPER BUS BAR AND ENCLOSURE TO BE DETERMINED BY

NUMBER OF CONDUCTOR CONNECTIONS.

3. PROVIDE LABEL ON DOOR "ORDNANCE GROUND TEST POINT."

BONDING CABLEEXOTHERMIC WELD - INTERSECTION MOLD

GROUND ROD

EXOTHERMIC WELD - GROUND ROD/ CONDUCTOR MOLD

CONDUCTOR

MOLD

CONDUCTOR

MOLD

BUS TERMINAL

CABLE TO METAL CONNECTION

BONDING LUG

PARALLEL

COMBINATION CABLE

TO WIRE SPLICER

MAIN LIGHTNING

PROTECTION CONDUCTOR

E3

TYPICAL CABLE

TERMINATIONS/CONNECTIONS DETAIL

SCALE: NO SCALE E6

TYPICAL CABLE

EXOTHERMIC WELD DETAIL

SCALE: NO SCALE E8

TYPICAL CABLE SPLICE DETAIL

SCALE: NO SCALE

C

600V ELECTRICALLY HELD

CONTACTOR 30 AMP.

RATED CONTACTS WITH

HOA SWITCH

PC

INLINE 120V PHOTOCELL INTERMATIC-MOUNT ON

ROOF AIM TO NORTH.

120V

N

B8

MSM EXTERIOR LIGHTING CONTROL

SCALE: NO SCALE

TO EXTERIOR BLDG MT. LIGHTS

SPARE

SPARE

SPARE

HA#-7

HA#-9 TO EXTERIOR BLDG MT. LIGHTS

EXOTHERMIC WELD (TYP)

CABLE TO REBAR CONNECTION

#2/0 BARE CU CONDUCTOR (TYP)

1'-0" MAX FROM

BOTTOM EDGE OF

BUILDING

REBAR (TYP)

TO EARTH ELECTRODE

SYSTEM (TYP)

#2/0 BARE CU

CONDUCTOR (TYP)

CONDUCTOR TO REBAR OR

WIREMESH CONNECTION

EXOTHERMIC WELD TYPICAL

EVERY 4'-0"

CONDUCTOR TO WIREMESH

CONNECTION IN FLOOR EVERY

4'-0"

#2/0 BARE CU CONDUCTOR

PROVIDE SUFFICIENT

SLACK FOR 1" EXPANSION

CONDUCTOR

TO REBAR

CONNECTION

IN WALL

EVERY 4'-0"

EXOTHERMIC

WELD (TYP)

D8

GROUNDING REINFORCING STEEL

SCALE: NO SCALE

D6

AT EACH CONSTRUCTION JOINT

SCALE: NO SCALE

TYPICAL BOND CONNECTION

A6

FLOOR TO WALL/ROOF CONNECTION

SCALE: NO SCALE

NOTE 1:

NOTE 2:

M

IN

1'-6" (MIN.)

8''x4' TERRACOTTA TILE, PVC, OR CONCRETE

PIPE FILLED WITH

SAND/GRAVEL MIX

(SEE NOTE 2)

3/4" GROUND ROD

BONDING CONNECTOR

#2/0 BARE CU GROUND

CONDUCTORS (TYP)

(SEE NOTE 1)

3/4"X10' GROUND ROD

(MINIMUM SIZE)

ORIGINAL (NATURAL)

GRADE

#2/0 CU CONDUCTOR IN 1"

PVC CONDUIT BACK TO

ORDNANCE GROUND INSERT.

SEE "ORDNANCE GROUND

INSERT DETAIL" ON SHEET E-502.

(TYP ONLY FOR GROUND TEST

WELL BONDED TO ORDNANCE

GROUND SYSTEM)

GROUND CONDUCTORS

BOLTED (REMOVABLE FOR

PERIODIC TESTING) TO

THE BONDING

CONNECTOR

CAST IRON COVER

WITH FINGER

HOLE (SEE NOTE 2)

THE DEPTH OF GROUND ROD BELOW NATURAL GRADE SHALL BE SITE ADAPTED TO SUIT LOCAL

SOIL CONDITION. AT NO TIME SHALL THE MINIMUM DEPTH BE LESS THAN 10'-0".

MAINTAIN THE GROUND CONDUCTORS ISOLATED FROM THE GROUND ROD UNTIL

THE BOND CONNECTION AT THE TOP

PROVIDE "TRAFFIC RATED" TEST WELL AND COVER FOR PAVED AREAS

FINISHED

FILL GRADE

LEVEL

2'-0"

(MIN)

A3

INSTALLATION IN EARTH FILL

SCALE: NO SCALE

GROUND TEST WELL

GROUND CONNECTION (TYP)

SECONDARY GROUND RING

BOND TO REBAR

#2/0 BARE CU CONDUCTOR TO

SECONDARY GROUND RING

CU GROUND BAR

RE: E7/E-501

SINGLE CONDUCTOR

COMPRESSION

CONNECTOR (TYP)

#2/0 BARE CU

CONDUCTOR TO

INCOMING CONDUIT OR

CIRCUIT (TYP)

A1

SINGLE POINT GROUND BAR

CONNECTIONS DETAIL

SCALE: NO SCALE

#4/0 CU GROUNDING

ELECTRODE CONDUCTOR

TO PANEL "HAXX"

NOTE:

WALL TO ROOF BONDING WILL BE SIMILAR WITH #2/0 BARE CU

CONDUCTOR BONDING THE WALL MATS AND ROOF MATS EVERY 4'-0".

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-502

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

D E

T A

IL

S

SCALE: NO SCALED1

ORDNANCE GROUND TEST POINT

NOTES:

1. NUMBER OF CONDUITS AS REQUIRED FOR THE APPLICATION.

2. SCHEDULE 40 PVC CONDUIT, UNLESS INDICATED OTHERWISE.

3. PROVIDE BARE COPPER GROUND CONDUCTOR FOR MEDIUM VOLTAGE

DISTRIBUTION DUCTBANKS AND DUCTBANKS SERVING BUILDINGS.

4. BOND BARE COPPER GROUND CONDUCTOR TO GROUND LOOPS IN

MANHOLES AND GROUND RINGS AT ALL EQUIPMENT PADS.

5. PROVIDE BASE AND INTERMEDIATE PLASTIC SPACERS FOR DUCTBANK

CONDUIT WITH A 3" MINIMUM SEPARATION (EVERY 6 FEET).

6. CEMENT SHALL BE ASTM C150 TYPE V.

7. DUCTBANKS SHALL BE REINFORCED AS REQUIRED BY SPECIFICATIONS,

UNDER STRUCTURES, TRAFFIC AREAS, AND FOR A MIN. DISTANCE OF

10 FT ON EITHER SIDE OF TRAFFIC AREAS.

8. ALL POWER AND COMMUNICATIONS CONDUITS SHALL BE IN PVC COATED

RGS CONDUIT FOR AT LEAST 50 FT PRIOR TO ENTERING THE MSMs.

9. PROVIDE MINIMUM 12" HORIZONTAL CLEARANCE FROM OTHER UTILITIES. FIELD

VERIFY EXISTING UTILITY LOCATIONS.

M

IN

IM

U

M

3" MINIMUM 3" MINIMUM

12"

MINIMUM

D E

P T

H

M

IN

O R

A S

S P

E C

IF

IE

D

M

IN

IM

U M

NOTE 1

M

IN

IM

U

M

T Y

P

IC

A L

FINISH GRADE

CONCRETE

ENCASEMENT

WARNING TAPE

BETWEEN POWER &

COMMUNICATIONS

M

IN

IM

U

M

3" MINIMUM 3" MINIMUM

12"

MINIMUM

D E

P T

H

M

IN

O R

A S

S P

E C

IF

IE

D

M

IN

IM

U M

M

IN

IM

U

M

T Y

P

IC

A L

FINISH GRADE

(GRASS)

WARNING TAPE

BETWEEN POWER &

COMMUNICATIONS

INITIAL BACKFILL

PER

SPECIFICATION 31

00 00 EARTHWORK

BACKFILL USING

EXCAVATED

MATERIALS

NOTES:

1. CONTRACTOR SHALL RESTORE DISTURBED AREA TO MATCH SURROUNDING AREA.

2. SCHEDULE 40 PVC CONDUIT, UNLESS INDICATED OTHERWISE.

3. DUCTBANKS SHALL BE REINFORCED AS REQUIRED BY SPECIFICATIONS,

UNDER STRUCTURES, TRAFFIC AREAS, AND FOR A MIN. DISTANCE OF

10 FT ON EITHER SIDE OF TRAFFIC AREAS.

4. ALL POWER AND COMMUNICATIONS CONDUITS SHALL BE IN PVC COATED

RGS CONDUIT FOR AT LEAST 50 FT PRIOR TO ENTERING THE MSMs.

5. PROVIDE MINIMUM 12" HORIZONTAL CLEARANCE FROM OTHER UTILITIES. FIELD

VERIFY EXISTING UTILITY LOCATIONS.

#4/0 BARE GND

CONDUCTOR

(LENGTH OF

DUCTBANK)

E8

DIRECT BURY CONDUIT DETAIL

SCALE: NO SCALEE6

CONCRETE

ENCASED DUCT BANK DETAIL

SCALE: NO SCALE

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-503

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

D E

T A

IL

S

CONDUIT/PIPE

SIDE VIEWBOTTOM VIEWS

LOOP

CONDUCTOR AT

TERMINAL END

BRONZE

GROUND

CLAMP

GROUND CONDUCTOR TO

NEXT CONDUIT/PIPE

BRONZE GROUND CLAMP.

SIZE TO SUITE ACTUAL

CONDUIT/PIPE

CONDUIT/PIPE. CONFIRM

ACTUAL SIZE

BARE COPPER (STANDARD)

GROUNDING CONDUCTORS

GROUND CONDUCTOR FROM GROUND

GIRDLE, GROUND BUS, ET CETERA

1. CONCEAL GROUNDING CONDUCTORS WHERE POSSIBLE

ΝOTES:

GROUNDING CONDUCTOR

ZINC COATED STEEL WASHER

ZINC COATED, HEX HEAD, STEEL JAM NUT

MΑS0ΝRY WALLCONCRETE WALL

SIDE VIEWSLATERAL VIEWTOP VIEW

2. FOR GROUNDING CONDUCTORS RUN EXPOSED, SUPPORT

CONDUCTORS 36" ON CENTERS AND WITHIN 12" OF

GROUND CONNECTIONS.

3. PROVIDE WALL FASTENER IN ACCORDANCE WITH THE WALL TYPE

SEE "SIDE VIEW DETAILS" FOR REQUIREMENTS

1/4" - 20 THREADED STEEL STUD, ZINC COATED.

MAY APPLY BY EXPLOSIVE CHARGE METHOD

1/4" - 20 HEX HEAD,

ZINC COATED STEEL

MACHINE SCREW

MACHINE SCREW

ANCHOR. LOCATE ONLY

IN A MORTAR JOINT

ZINC COATED STEEL WASHER

GROUNDING CONDUCTOR. SIZE AS INDICATED

SIDE ENTRANCE CABLE LUG.

SIZED FOR ACTUAL CONDUCTOR.

SIDE ENTRANCE CABLE LUG.

SIZED FOR ACTUAL CONDUCTOR.

ZINC COATED

STEEL WASHER

BARE COPPER (STRANDED) GROUNDING

CONDUCTOR. PROVIDE SIZES AS INDICATED

ZINC COATED

STEEL WASHER

SECONDARY GROUND RING

HEADWALL

ALUMINIUM

PIPE GUARDRAILS

V A

R

IE

S

EXOTHERMIC

CONNECTION (TYP)

REINFORCING

STEEL (TYP)

FOR CONNECTION TO

STEEL DOOR ASSEMBLY

DOWN CONDUCTOREXTERNAL

TO BUILDING (TYP)

SUPPORT BASE (TYP)

HIGH COMPRESSION CLAMP

EXOTHERMIC WELD

WALL

WELD TO CHANNEL PLATE

EXOTHERMIC WELD OR HIGH COMPRESSION CLAMP

ROOF TOPPING SLAB

FLOOR

HIGH COMPRESSION CLAMP

GROUTING TUBE

WALL

ROOF

NOTES:

1. TACK WELDS MAY BE USED AS AN ALTERNATE BONDING METHOD TO WIRE TIES.

2. BONDING AND GROUNDING NOTE: ELECTRICAL BONDING REQUIREMENTS INTERNAL TO PRECAST ROOF AND WALL PANELS SHALL BE PROVIDED BY

THE PRECAST MANUFACTURER IN ACCORDANCE WITH THE STRUCTURAL DRAWINGS. ELECTRICAL BONDING REQUIREMENTS EXTERNAL TO

PRECAST PANELS AND WITHIN CAST-IN-PLACE CONCRETE SLABS SHALL BE FIELD INSTALLED.

#2/0 BARE CU WIRE.

PROVIDE AT 48" O.C.

CHANNEL PLATES WELDED

TOGETHER AT ALL PRECAST JOINTS (TYP)

WIRE TIE HEADED STUDS TO

REBAR CAGE @ 48" EA FACE

WIRE TIE REBAR TO HEADED STUDS

ON CHANNELS @ 48" O.C.

WALL-TO-FOOTING PIGTAILS. MAKE AS

SHORT AS PRACTICAL. MIN 24" x #2/0

BARE CU WIRE. PROVIDE AT EVERY WALL

PANEL JOINT AND EXOTHERMICALLY WELD

TO VERTICAL CHANNEL.

SECONDARY GROUNDING

RING. SEE SHT. E-103

WALL-TO FOOTING TO SECONDARY RING PIGTAIL (REBAR CONNECTION), PROVIDE #2/0 BARE CU

AT A MINIMUM OF FOUR PLACES PER MAGAZINE. SEE SHEET E-103.

PIGTAIL TO CONNECT FOOTING TO FLOOR SLAB REBAR. ROUTE THROUGH

ROCK FILL. PROVIDE AT 48" SPACING ALONG ENTIRE FOOTING.

#4 AWG BARE COPPER WIRE TWISTED

IN FIGURE 8 PATTERN SECURELY AROUND

REBAR JOINT TYPICAL AT 48" MAX SPACING

IN ALL WALL, FLOOR, FOOTINGS, STEMWALL

AND ROOF SECTIONS SEE STRUCTURAL

DRAWINGS FOR ADDITIONAL DETAIL.

BONDING REQUIREMENTS APPLY TO BOTH

THE INNER AND OUTER REBAR MATS.

D1

WALL/FLOOR/ROOF BONDING DETAIL (TYPICAL)

SCALE: NO SCALE

E5

CONDUIT/PIPE GROUND CONNECTION

SCALE: NO SCALE

E8

GROUND SECTION

SCALE: NO SCALE

B7

GROUNDING CONDUCTOR SUPPORT DETAILS

(TYPICAL FOR EXPOSED CONDUCTORS)

SCALE: NO SCALE

1/2" DIA. COPPER DOWEL ROD WITH 90 DEG. BEND

1/2" DIA. COPPER DOWEL ROD WITH 90 DEG.

BEND AT 48" MAX. INTERVALS BETWEEN PANEL

JOINTS/VERTICAL CHANNEL

1/2" DIA. COPPER REBAR

WITH 90 DEG. BEND

3. ALL REBAR IN CONCRETE FLOOR, WALLS, AND ROOF COMPRISING THE ENVELOPE OF THE MAGAZINE SHELL WILL BE ELECTRICALLY CONTINUOUS.

REBAR IN CONCRETE FOR THE MECHANICAL ROOM, RETAINING WALL, AND RETAINING WALL FOOTINGS, ARE NOT REQUIRED TO BE ELECTRONICALLY CONTINUOUS.

400A

PANEL

600A

DOCKING

STATION

A

D

IS

T P

A N

E L

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

#6 BARE

COPPER

#4/0 BARE

COPPER

#4/0 BARE

COPPER

#6 BARE

COPPER

TYPICAL TRANSFORMER SKID FOR SERVICE TO 4 MAGAZINE BUILDINGS

#1/0 BARE

COPPER

NOTE: CONCRETE PAD, MEDIUM VOLTAGE TRANSFORMER AND

GROUNDING SHALL BE PART OF PACKAGE 2 MTF SCOPE. LOW VOLTAGE

EQUIPMENT IS SHOWN FOR REFERENCE ONLY.

600A

PANEL

600A

DOCKING

STATION

A

D

IS

T P

A N

E L

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

#6 BARE

COPPER

#4/0 BARE

COPPER

#4/0 BARE

COPPER

#6 BARE

COPPER

TYPICAL TRANSFORMER SKID FOR SERVICE TO 5 MAGAZINE BUILDINGS

#2/0 BARE

COPPER

NOTE: CONCRETE PAD, MEDIUM VOLTAGE TRANSFORMER AND

GROUNDING SHALL BE PART OF PACKAGE 2 MTF SCOPE. LOW VOLTAGE

EQUIPMENT IS SHOWN FOR REFERENCE ONLY.

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

3/4" x 10'-0"

SOLID COPPER

GROUND ROD

SKID SKID

EPM

#8 BARE

COPPER

EPM

#8 BARE

COPPER

RACK MOUNTED

ELECTRIC METER.

REFER TO DETAIL

E2/E-505.

RACK MOUNTED

ELECTRIC METER.

REFER TO DETAIL

E2/E-505.

NOTE:

TRANSFORMER SKIDS ARE EXISTING TO REMAIN. DETAIL INCLUDED

FOR REFRENCE ONLY TO DEPICT EXISTING CONDITIONS

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-504

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

D E

T A

IL

S

SCALE: NO SCALEA1

MSM TRANSFORMER SKID DETAIL

LED ENCLOSED AND GASKETED

NL-11LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

1. HOUSING - IMPACT-RESISTANT POLYCARBONATE HOUSING, WITH ALUMINUM COMPONENT

TRAY AND HEAT SINK. OPTIONAL LENGTHS OF 4FT OR 8FT.

2. LENS - IMPACT-RESISTANT ACRYLIC OR OPTIONAL POLYCARBONATE, WITH CONTINUOUS

CLOSED-CELL POLYURETHANE GASKET, SECURED WITH STAINLESS STEEL OR POLYCARBONATE

3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70, 3500K CCT

UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING TOLERANCE FOR COLOR

CONSISTENCY, AND MINIMUM EFFICACY OF 100 LUMENS/WATT. INITIAL LUMEN OUTPUT AS

4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING

VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION. ON-OFF

CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.

5. CERTIFICATION - UL 1598, WET LOCATION (IP65, IP66, IP67), DLC QUALIFIED, AND ROHS

COMPLIANT. COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN

6. MOUNTING - SURFACE-MOUNTED OR SUSPENDED FROM CEILING.

7. OPTIONS - EMERGENCY BACK-UP.

8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY

MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN

LATCHES.

INDICATED IN LUMINAIRE SCHEDULE.

EQUIPPED WITH EMERGENCY BATTERY BACK-UP.

MANUFACTURER OR PREFERENCE.

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE-CAST ALUMINUM HOUSING HAS INTEGRAL HEAT SINK FINS TO OPTIMIZE

THERMAL MANAGEMENT THROUGH CONDUCTIVE AND CONVECTIVE COOLING. HOUSING IS

COMPLETELY SEALED AGAINST MOISTURE AND ENVIROMENTAL CONTAMINANTS.

2. FINISH - ZINC-INFUSED SUPER DURABLE TGIC THERMOSET POWDER COAT FINISH. FINISH

SHALL PASS 2500 HOUR SALT SPRAY TEST PER ASTM B117. STANDARD FINISH IS DARK

BRONZE, WITH OTHER CUSTOM COLORS AVAILABLE.

3. POWER SUPPLY/LED DRIVER - CLASS 1 DRIVER SHALL OPERATE AT 120/277 VOLTS, 50/60 HZ, WITH OTHER VOLTAGES OPTIONAL; POWER FACTOR GREATER THAN 0.9 AND THD LESS THAN

20% AT FULL LOAD. MINIMUM EFFICACY SHALL BE 60 LM/W AT MAXIMUM 600mA OPERATING

4. LED OPTICAL ASSEMBLY - PRECISION MOLDED ACRYLIC LENS PROVIDED FOR MULTIPLE

HIGH-POWERED LEDS PRODUCING NEMA TYPE III DISTRIBUTION OR AS OTHERWISE INDICATED.

BUG UPLIGHT RATING OF U0, WITH GLARE RATING AS DETERMINED BY LIGHTING ZONE

INSTALLED. MINIMUM COLOR RENDERING INDEX (CRI) SHALL BE 70 FOR CORRELATED COLOR

5. CERTIFICATION - UL AND/OR ETL LISTED FOR DAMP OR WET LOCATIONS AS INDICATED, AND

RoHS COMPLIANT.

6. OPTIONS - VARIOUS LUMEN OUTPUT RATING AS INDICATED, AND 0-10 VOLT DIMMING DRIVER.

7. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETY GRAPHIC REPRESENTATION OF A

LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO

INDICATE A CERTAIN MANUFACTURER'S PREFERENCE. ALL DIMENSIONS ARE NOMINAL AND

XL-17LUMINAIRE PLATE:

LED WALL PACK

CURRENT.

TEMPERATURE (CCT) OF 4000-4500 DEGREES K.

VARY PER MANUFACTURER. MANUFACTURER'S PREFERENCE. ALL DIMENSIONS ARE NOMINAL

AND VARY PER MANUFACTURER.

XL-21LUMINAIRE PLATE:

LED FLOOD LUMINAIRE

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE CAST ALUMINUM WITH INTEGRAL HEAT SINK FINS TO OPTIMIZE THERMAL

MANAGEMENT THROUGH CONDUCTIVE AND CONVECTIVE COOLING. HOUSING IS COMPLETELY

SEALED AGAINST MOISTURE AND ENVIROMENTAL CONTAMINANTS.

2. FINISH - ZINC-INFUSED SUPER DURABLE TGIC THERMOSET POWDER COAT FINISH. FINISH

THAT CAN WITHSTAND EXTREME CLIMATE CHANGES WITHOUT CRACKING OR PEELING.

3. POWER SUPPLY/LED DRIVER - CLASS 1 ELECTRONIC DRIVER SHALL OPERATE AT 120/277

VOLTS, 50/60 HZ, WITH OTHER VOLTAGES OPTIONAL. POWER FACTOR SHALL BE GREATER THAN

0.9 AND THD LESS THAN 20% AT FULL LOAD. MINIMUM EFFICACY SHALL BE 60 LM/W AT

MAXIMUM 600mA OPERATING CURRENT.

4. LED OPTICAL ASSEMBLY - VARIETY OF PERCISION MOLDED VACUUM METALLIZED SPECULAR

REFLECTORS ARE ENGINEERED FOR SUPERIOR TARGET ILLUMINATION. MINIMUM COLOR

RENDERING INDEX (CRI) OF 70 FOR CORRELEATED COLOR TEMPERATURE OF 4000-4500

5. LENS - TEMPERED GLASS IN DIE-CAST ALUMINUM FRAME WITH SILICONE GASKET.

6. SURGE PROTECTION - 6 KV MINIMUM, COMPLIANT WITH ANSI C62.41.2.

7. CERTIFICATION - UL AND/OR ETL LISTED FOR WET LOCATIONS AND 2G VIBRATION STANDARD

PER ANSI C136.32. OPTICAL ASSEMBLY SHALL BE MINIMUM IP65 PER ANSI/IEC 60529.

8. OPTIONS - FINISH COLOR, OUTPUT DISTRIBUTION TYPE AND TRUNNION OR SLIPFITTER

TYPE MOUNTING.

9. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A

LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO

INDICATE A CERTAIN MANUFACTURER'S PREFERENCE. ALL DIMENSIONS ARE NOMINAL AND VARY

PER MANUFACTURER.

DEGREES K.

RACK MOUNTED LOCKABLE NEMA-4X SS

ENCLOSURE WITH HINGED DOOR AND BACK

PANEL FOR INTERIOR DEVICE MOUNTING.

ELECTRICAL METER. IN ENCLOSURE DOOR.

BMS DATA OUTLET MOUNTED TO BACK PANEL.

PROVIDE 8P8C CONNECTOR.

3' CAT6 PATCH CABLE FROM OUTLET TO METER.

2" PVC COATED RIGID CONDUIT WITH ONE

OUTDOOR RATED CAT6 CABLE FROM

NEAREST MAGAZINE MECHANICAL ROOM.

REFER TO SITE PLANS FOR LOCATIONS.

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-505

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

D E

T A

IL

S

SCALE: NO SCALEE2

ELECTRIC POWER METER INSTALLATION

A1

MEDIUM VOLTAGE ELECTRICAL ONE-LINE DIAGRAM

NOT TO SCALE

NO

300 kVA

XFMR. #3A

480Y/277V Z = 5.75%

480Y/277V Z = 5.75%

XFMR. #4A

225 kVA

NC NC"T"

SWITCH

(200A)

12.47 kV :12.47 kV :

NCNC

225 kVA

XFMR. #1A

480Y/277V Z = 5.75%

480Y/277V Z = 5.75%

XFMR. #2A

300 kVA

NO NC

12.47 kV :12.47 kV :

NC

SERVICE-

ENTRANCE

PANEL 'MP11'

SERVICE-

ENTRANCE

PANEL 'MP21'

SERVICE

ENTRANCE

PANEL 'MP41'

SEE: A1/E-601

FI FIFI FIFI FIFI FI

TRANSFORMER SKID 2 TRANSFORMER SKID 3 TRANSFORMER SKID 4

MH-1

MH-3

TRANSFORMER SKID 1

UNDERGROUND CABLE

IN NEW DUCTBANK

3-#2, 15kV, U.G. LINE

4" PVC (TYP)

NC

CLP

RISER POLE &

FUSED CUTOUTS

NEW CLP

PRIMARY POLE

200A

NC

CLP

RISER POLE &

FUSED CUTOUTS

200A

R

(TYP)

15kV RECLOSER

200A

VFI

200A

VFI

200A

VFI

200A

VFI

AUTOMATIC SOURCE

TRANSFER CONTROL

SCHEME

SEL-451

RELAY

600/5 600/5

3 3

15KV, 600A, 3-PHASE

MV 6-WAY

PADMOUNTED

SWITCHGEAR

12.47kV AERIAL SERVICE 12.47kV

AERIAL SERVICE

600A

NC

VFI

600A

NO

VFI 5-PORT

SWITCH

SEL

700GW

SEL

700GW

M M

TO RECLOSER

WITH

COMMUNICATIONS

CONTROL WIRE (TYP)

2" C WITH COPPER

ETHERNET

COMMUNICATIONS (TYP)

MOTOR OPERATOR

SWITCH (TYP)

UNDERGROUND

CABLE IN NEW

DUCTBANK

3#1/0, 15KV U.G. LINE

4"C PVC

MH-2

7200/1207200/120

200/5 200/5 200/5 200/5

SERVICE

ENTRANCE

PANEL 'MP31'

SEE: A4/E-601

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-600

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

M V

D

IS

T R

IB

U

T

IO

N O

N E

-L

IN

E

GENERAL SHEET NOTES:

1. ALL MEDIUM VOLTAGE PRIMARY WORK INCLUDING SERVICE TRANSFORMER IS EXISTING TO

REMAIN. SHOWN FOR REFERENCE ONLY.

SCHEDULED SERVICE AMPACITY: 1000 AMPS

TOTAL AMPACITY: 1068 AMPS

25% SPARE 214 AMPS

TOTAL AMPACITY: 854 AMPS

TOTAL SERVICE OF 18

SCHEDULED SERVICE AMPACITY: 450 AMPS

TOTAL AMPACITY: 295 AMPS

25% SPARE 59 AMPS

TOTAL AMPACITY: 236 AMPS

TOTAL SERVICE OF 5 (TYPICAL)

SCHEDULED SERVICE AMPACITY: 350 AMPS

TOTAL AMPACITY: 242 AMPS

25% SPARE 48 AMPS

TOTAL AMPACITY: 193 AMPS

TOTAL SERVICE OF 4 (TYPICAL)

EACH MSM BUILDING AMPACITY: 80 AMPS

TOTAL AMPACITY: 59 AMPS

25% SPARE 12 AMPS

DEMAND AMPACITY 47 AMPS

SERVICE VOLTAGE: 480 VOLTS

EACH MSM BUILDING:

TOTAL 47 39 47 39

LARGEST MOTOR (25%) 1 1 1 1

CONTINUOUS MOTORS: 6 5 6 5

AC/HEATING: 35 29 35 29

LIGHTING: 3 2 3 3

RECEPTACLES: 1 1 1 1

EQUIPMENT: 0 0 0 0

TYPE AMPACITY KVA AMPACITY KVA

CONNECTED DEMAND

NEW NEW

MAIN DISTRIBUTION: PANEL MDB 480 VOLT

SQ FOOTAGE: 2320 SF

PROJECT NUMBER: 10121996

PROJECT: UTTR - MSM

SERVICE LOAD ANALYSIS

MAIN DISTRIBUTION PANEL 'MDA4'

400A, 480/277V, 3PH, 4W, NEMA 3R, 35 KAIC

SPD

PANEL

'HA41'

480/277V 80A

MCB

N

G

PANEL

'LA41'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

MSM SITE

MSM ELEC/

MECH ROOM

TO 225KVA XFMR

RE: 1/E-600

DOCKING STATION

600A/480Y/277V/3PH/4W/N3R

35 KAIC

N

GPHASE

ROTATION

MALE

CAM

LOCK

HARDWIRE

LUG

A1

FOUR MAGAZINE BUILDINGS

ELECTRICAL ONE-LINE RISER DIAGRAM

NOT TO SCALE

N

G

SERVICE ENTRANCE

RATED PANEL

480V/3PH/N3R/400A

35 KAIC, RACK

MOUNTED (TYP)

MTS

A4

FIVE MAGAZINE BUILDINGS

ELECTRICAL ONE-LINE RISER DIAGRAM

NOT TO SCALE

S P

D

TRANSFORMER

SKID 4

CONNECTION

FOR

TEMPORARY/

PORTABLE

GENERATOR

350N

350N

80G

100N

80N 80G

350NG

#6 GEC

#1/0

GEC

EPM AMRS COMPLIANT

ELECTRIC METER

LTG

CON

PC

LIGHTING

CONTACTOR

RE: B8/E-502

(TYP)

MAIN DISTRIBUTION PANEL 'MDA3'

600A, 480/277V, 3PH, 4W,

NEMA 3R, 35 KAIC

SPD

MSM SITE

MSM ELEC/

MECH ROOM

TO 300KVA XFMR

RE: 1/E-600

DOCKING STATION

600A/480Y/277V/3PH/4W/N3R

35 KAIC

N

GPHASE

ROTATION

MALE

CAM

LOCK

HARDWIRE

LUG

N

G

SERVICE ENTRANCE

RATED PANEL

480V/3PH/N3R/600A

35 KAIC, RACK

MOUNTED (TYP)

MTS

S P

D

TRANSFORMER

SKID 3

CONNECTION

FOR

TEMPORARY/

PORTABLE

GENERATOR

450N

450N

80G 80N

450NG

#2/0

GEC

EPM

PANEL

'HA42'

480/277V 80A

MCB

PANEL

'LA42'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

LTG

CON

PC

80N

PANEL

'HA43'

480/277V 80A

MCB

PANEL

'LA43'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

LTG

CON

PC

PANEL

'HA44'

480/277V 80A

MCB

PANEL

'LA44'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

LTG

CON

PC

N

G

PANEL

'HA31'

480/277V 80A

MCB

PANEL

'LA31'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

LTG

CON

PC

LIGHTING

CONTACTOR

RE: B8/E-502

(TYP)

PANEL

'HA32'

480/277V 80A

MCB

PANEL

'LA32'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

LTG

CON

PC

80N

PANEL

'HA33'

480/277V 80A

MCB

PANEL

'LA33'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

PC

LTG

CON

80N

PANEL

'HA34'

480/277V 80A

MCB

PANEL

'LA34'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

PC

LTG

CON

80G

PANEL

'HA35'

480/277V 80A

MCB

PANEL

'LA35'

208/120V 100A

MCB

TRANSFORMER

Δ480V-208Y/120V

30KVA/3PH/4W

S P

D S

P D

100N

#6 GEC

PC

LTG

CON

60 60

S P

D

S P

D

PANEL 'MP41' PANEL 'MP31'

2 2 2 2 2 2 2 2 2

4 4

MANUAL TRANSFER SWITCH, 600A/4P MANUAL TRANSFER SWITCH, 600A/4P

AMRS COMPLIANT

ELECTRIC METER

#1/0

GEC

#2/0

GEC

20A 1P

TO EPM TO EPM6 6SPARE SPARE SPARE SPARE

6 6

350AT

400AF

350AT

400AF

LSI

450AT

600AF

450AT

600AF

LSI

60AT

100AF

60AT

100AF

20A 1P

Z = 4.6% Z = 4.6% Z = 4.6% Z = 4.6% Z = 4.6% Z = 4.6% Z = 4.6% Z = 4.6% Z = 4.6%

80AT

100AF

60AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

60AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

80AT

100AF

MSM

30312

MSM

30311

MSM

30310

MSM

30309

MSM

30317

MSM

30316

MSM

30315

MSM

30314

MSM

30313

SEE GENERAL

NOTES 1 AND 2

SEE GENERAL

NOTES 1 AND 2

7 7 7 7 7 7 7 7 7

FEEDER SCHEDULE

PHASE NEUTRAL GROUND FEEDER

TAG CONDUIT CONDUCTORS CONDUCTORS CONDUCTORS AMPS

30 (1) - 3/4" WITH (3) - #10 - (1) - #10 30

30N (1) - 3/4" WITH (3) - #10 (1) - #10 (1) - #10 30

40 (1) - 3/4" WITH (3) - #8 - (1) - #10 40

40N (1) - 3/4" WITH (3) - #8 (1) - #8 (1) - #10 40

50 (1) - 3/4" WITH (3) - #6 - (1) - #10 55

50N (1) - 1" WITH (3) - #6 (1) - #6 (1) - #10 55

60 (1) - 1" WITH (3) - #4 - (1) - #10 70

60N (1) - 1-1/4" WITH (3) - #4 (1) - #4 (1) - #10 70

70 (1) - 1" WITH (3) - #4 - (1) - #8 70

70N (1) - 1-1/4" WITH (3) - #4 (1) - #4 (1) - #8 70

80 (1) - 1" WITH (3) - #3 - (1) - #8 85

80N (1) - 1-1/4" WITH (3) - #3 (1) - #3 (1) - #8 85

90 (1) - 1-1/4" WITH (3) - #2 - (1) - #8 95

90N (1) - 1-1/4" WITH (3) - #2 (1) - #2 (1) - #8 95

100 (1) - 1-1/4" WITH (3) - #1 - (1) - #8 110

100N (1) - 1-1/2" WITH (3) - #1 (1) - #1 (1) - #8 110

125 (1) - 1-1/2" WITH (3) - #1 - (1) - #6 130

125N (1) - 1-1/2" WITH (3) - #1 (1) - #1 (1) - #6 130

150 (1) - 1-1/2" WITH (3) - #1/0 - (1) - #6 150

150N (1) - 1-1/2" WITH (3) - #1/0 (1) - #1/0 (1) - #6 150

175 (1) - 1-1/2" WITH (3) - #2/0 - (1) - #6 175

175N (1) - 2" WITH (3) - #2/0 (1) - #2/0 (1) - #6 175

200 (1) - 2" WITH (3) - #3/0 - (1) - #6 200

200N (1) - 2" WITH (3) - #3/0 (1) - #3/0 (1) - #6 200

225 (1) - 2" WITH (3) - #4/0 - (1) - #4 230

225N (1) - 2-1/2" WITH (3) - #4/0 (1) - #4/0 (1) - #4 230

250 (1) - 2" WITH (3) - #250 - (1) - #4 255

250N (1) - 2-1/2" WITH (3) - #250 (1) - #250 (1) - #4 255

300 (1) - 2-1/2" WITH (3) - #350 - (1) - #4 310

300N (1) - 3" WITH (3) - #350 (1) - #350 (1) - #4 310

350 (1) - 3" WITH (3) - #500 - (1) - #3 380

350N (1) - 3-1/2" WITH (3) - #500 (1) - #500 (1) - #3 380

400 (2) - 2" EA. WITH (3) - #3/0 - (1) - #3 400

400N (2) - 2" EA. WITH (3) - #3/0 (1) - #3/0 (1) - #3 400

450 (2) - 2" EA. WITH (3) - #4/0 - (1) - #2 460

450N (2) - 2-1/2" EA. WITH (3) - #4/0 (1) - #4/0 (1) - #2 460

500 (2) - 2" EA. WITH (3) - #250 - (1) - #2 510

500N (2) - 2-1/2" EA. WITH (3) - #250 (1) - #250 (1) - #2 510

600 (2) - 2-1/2" EA. WITH (3) - #350 - (1) - #1 620

600N (2) - 3" EA. WITH (3) - #350 (1) - #350 (1) - #1 620

700 (2) - 3" EA. WITH (3) - #500 - (1) - #1/0 760

700N (2) - 3-1/2" EA. WITH (3) - #500 (1) - #500 (1) - #1/0 760

800 (3) - 2-1/2" EA. WITH (3) - #300 - (1) - #1/0 855

800N (3) - 3" EA. WITH (3) - #300 (1) - #300 (1) - #1/0 855

900 (3) - 2-1/2" EA. WITH (3) - #350 - (1) - #2/0 930

900N (3) - 3" EA. WITH (3) - #350 (1) - #350 (1) - #2/0 930

1000 (3) - 3" EA. WITH (3) - #400 - (1) - #2/0 1,005

1000N (3) - 3" EA. WITH (3) - #400 (1) - #400 (1) - #2/0 1,005

1200 (4) - 2-1/2" EA. WITH (3) - #350 - (1) - #3/0 1,240

1200N (4) - 3" EA. WITH (3) - #350 (1) - #350 (1) - #3/0 1,240

450NG (2) - 2-1/2" EA. WITH (3) - #4/0 (1) - #4/0 - 460

80G (1) - 3" WITH (3) - #2 (1) - #2 (1) - #6 85

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-601

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

O N

E -L

IN

E

D

IA

G R

A M

1. REFER TO A5/E-501 FOR GROUNDING SYSTEM DETAIL.

2. PROVIDE EXTERNALLY MOUNTED SPD ON LOAD SIDE OF A DEDICATED CIRCUIT

BREAKER (BREAKER SIZE AND WIRE SIZE AS RECOMMENDED BY MANUFACTURE).

LOCATE AS CLOSE AS PRACTICAL TO THE BREAKER WITH A MAXIMUM LEAD OF 3FT.

3. PROVIDE A 480V/3PH/N3R/60A ENCLOSED CIRCUIT BREAKER FOR SPD.

4. PROVIDE A COMBINATION PHASE FAILURE / UNDERVOLTAGE RELAY FOR MAIN BREAKER

AND CAPACITOR TRIP DEVICE. MAIN BREAKER SHALL BE EQUIPPED WITH A SHUNT TRIP

TO TRIP THE BREAKER. UPON LOSS OF POWER OR LOSS OF A PHASE.

5. BOND THE GENERATOR-SIDE NEUTRAL OF THE MTS TO THE DOCKING STATION NEUTRAL

BUS WITH THE INDICATED SIZE COPPER CONDUCTOR. NEUTRAL BUS MUST BE KEPT

ISOLATED FROM ALL OTHER NEUTRAL CONDUCTORS/BUSSING. INSTALL A SYSTEM

BONDING JUMPER FROM THE DOCKING STATION NEUTRAL BUS TO A COMMON

GROUNDING BUS WITH THE INDICATED SIZE COPPER CONDUCTOR.

6. IF THE POWER METER REQUIRES A 120V POWER CONNECTION, PROVIDE A 277:120V

SINGLE PHASE TRANSFORMER AND CONNECT EPM TO THE TRANSFORMER SECONDARY.

7. ROUTE CONDUCTORS VIA EXISTING CONDUIT, UNDER SEPARATE CONTRACT. REFER TO

KEY NOTE 6/ES102 FOR ADDITIONAL INFORMATION.

SHEET KEYNOTES

GENERAL SHEET NOTES

1. ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH THE TRANSFORMER SKIDS IS

EXISTING TO REMAIN UNLESS NOTED OTHERWISE. TRANSFORMER SKID

EQUIPMENT, DESCRIPTIONS, AND WIRE SIZES IS INCLUDED FOR REFERENCE ONLY.

2. ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH THE INDIVIDUAL MAGAZINES WILL BE

FURNISHED AND INSTALL IN THIS CONTRACT. CONDUITS FROM DISTRIBUTION

PANELS 'MDA3' AND 'MDA4' TO THE INDIVIDUAL MAGAZINES IS INSTALLED TO 5'

OUTSIDE THE MAGAZINE FOUNDATION AND CAPPED AND MARKED. CONTRACTOR

RESPONSIBLE TO EXTEND CONDUIT AND FURNISH AND INSTALL ASSOCIATED

CONDUCTORS

1"1/2"0 2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C A

P

IT

A L P

R O

J E

C T

N O

K S

R M

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D M

IS

S

IL

E

M O

T O

R R

E C

E

IP

T /S

T O

R A

G E

F A

C

IL

IT

Y

U T

A H

T E

S T

T

R A

IN

IN

G R

A N

G E

U T

A H

READY TO ADVERTISE

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

-2

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

A N

U A

R Y

K S

R M

O

P T

IO

N

A L

M O

T O

R S

T O

R A

G

A Z

IN

E

S

SHEET OF

E-602

UTTR 464-3

E L

E C

T R

IC

A

L

K .L

E

F .O

L

IV

A R

E Z

H L

IU

P .D

A V

IL

A

S C

H E

D U

L E

S

EQUIPMENT CONNECTION SCHEDULE (TYPICAL PER MAGAZINE)

TAG DESCRIPTION LOCATION VOLTAGE PH kW FLA/MCA HORSEPOWER CB SIZE STARTER SIZE VFD LOCAL DISCONNECT SWITCH FEEDER SIZE PANEL

CIRCUIT

NUMBER

AC-XX AIR COMPRESSOR MECH/ELEC EQUIP 120 V 1 - 9.8A 1.5 HP 20A/1P - No MOTOR RATED SWITCH 2#10, #10 EGC, 3/4"C LA# 10

AHU (HEAT)-XX AIR HANDLING UNIT MECH/ELEC EQUIP 208 V 1 7.21 - - 50A/2P MFR (NOTE 1) No 60A/2P/NF/N1 2#8, #10 EGC, 3/4"C LA# 7,9

AHU(FAN)-XX AIR HANDLING UNIT MECH/ELEC EQUIP 208 V 1 - 4.1A FLA - 15A/2P MFR (NOTE 1) No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 12,14

BLAST DOOR MOTORIZED SLIDING BLAST DOOR ENTRANCE 480 V 3 - 2.1 FLA 1 HP 15A/3P - No MOTOR RATED SWITCH 3#10, #10 EGC, 3/4"C HA# 13,15,17

CU-XX CONDENSING UNIT MECH/ELEC EQUIP 208 V 1 - 18A MCA - 30A/2P MFR (NOTE 1) No 30A/2P/30AF/N3R 2#10, #10 EGC, 3/4"C LA# 17,19

DDC-1 DDC CONTROL PANEL MECH/ELEC EQUIP 120 V 1 - 1A - 20A/1P - No - 2#12, #12 EGC, 1/2"C LA# 1

DRAIN VALVE DRAIN VALVE MECH/ELEC EQUIP 120 V 1 - - 20A/1P - No - 2#12, #12 EGC, 1/2"C LA# 15

EF-XX EXHAUST FAN MECH/ELEC EQUIP 120 V 1 - 4.4A 1/6 HP 20A/1P MFR (NOTE 1) No MFR (NOTE 1) 2#12, #12 EGC, 1/2"C LA# 20

ESM-XX SNOW MELT MAT (NOTE 2) MAGAZINE DOOR-UNDER FLOOR 480 V 3 8 - - 20A/3P (GFEP) MFR (NOTE 1) No 30A/3P/NF/N3R 3#10, #10 EGC, 3/4"C (NOTE 3) HA# 10,12,14

EUH-XX ELECTRIC UNIT HEATER MECH/ELEC EQUIP 480 V 3 3.3 - - 20A/3P MFR (NOTE 1) No MFR (NOTE 1) 3#10, #10 EGC, 3/4"C HA# 1,3,5

FACU FIRE ALARM CONTROL UNIT MECH/ELEC EQUIP 120 V 1 - 2A - 20A/1P - No - 2#12, #12 EGC, 1/2"C LA# 13

GF-XX GAS FURNACE MECH/ELEC EQUIP 120 V 1 - 14.5A FLA 1 HP 20A/1P MFR (NOTE 1) No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 11

HVAC PNL SNOW MELT CONTROL PANEL MECH/ELEC EQUIP 120 V 1 - 1A - 20A/1P - No - 2#12, #12 EGC, 1/2"C LA# 3

IDS-MX IDS-MX 120 V 1 No LA# 21

MOD-XX-A MOTOR OPERATED DAMPER MECH/ELEC EQUIP 120 V 1 - 3A - 20A/1P - No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 4

MOD-XX-B MOTOR OPERATED DAMPER MECH/ELEC EQUIP 120 V 1 - 3A - 20A/1P - No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 4

MOD-XX-C MOTOR OPERATED DAMPER MECH/ELEC EQUIP 120 V 1 - 3A - 20A/1P - No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 4

MOD-XX-D MOTOR OPERATED DAMPER MECH/ELEC EQUIP 120 V 1 - 3A - 20A/1P - No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 6

MOD-XX-E MOTOR OPERATED DAMPER MECH/ELEC EQUIP 120 V 1 - 3A - 20A/1P - No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 6

MOD-XX-F MOTOR OPERATED DAMPER MECH/ELEC EQUIP 120 V 1 - 3A - 20A/1P - No MOTOR RATED SWITCH 2#12, #12 EGC, 1/2"C LA# 6

1. PROVIDE A GFEP TYPE (30mA TRIP) CIRCUIT BREAKER FOR SNOW MELT CABLE PROTECTION.

2. THIS EQUIPMENT APPLIES TO ONLY MAGAZINE 01.

Notes:

TOTAL ESTIMATED DEMAND + SPARE: 54 A

SPARE AMPERAGE: 20.00%

TOTAL ESTIMATED DEMAND 45 A

MTR 7687 VA 100.00% 7687 VA TOTAL CONNECTED: 45 A

REC 1080 VA 100.00% 1080 VA TOTAL ESTIMATED DEMAND: 37574 VA

LTS 2103 VA 100.00% 2103 VA TOTAL CONNECTED LOAD: 37574 VA

HVAC 3744 VA 100.00% 3744 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

PANEL TOTALS

TOTAL... 54 A 43 A 39 A

TOTAL... 14867 VA 11880 VA 10877 VA

41 SPACE -- -- -- 0.0 0.0 -- -- -- SPACE 42

39 SPACE -- -- -- 0.0 0.0 -- -- -- SPACE 40

37 SPACE -- -- -- 0.0 0.0 -- -- -- SPACE 38

35 36

33 34

31 32

29 SPARE -- 20 A 1 0.0 0.0 1 20 A -- SPARE 30

27 SPARE -- 20 A 1 0.0 0.0 1 20 A -- SPARE 28

25 SPARE -- 20 A 1 0.0 0.0 1 20 A -- SPARE 26

23 SPARE -- 20 A 1 0.0 0.0 1 20 A -- SPARE 24

21 SPARE -- 20 A 1 0.0 0.0 1 20 A -- SPARE 22

19 SPARE -- 20 A 1 0.0 0.0 1 20 A -- SPARE 20

17 -- -- -- -- 582.0 0.0 1 20 A -- SPARE 18

15 -- -- -- -- 582.0 0.0 1 20 A -- SPARE 16

13 MOTORIZED SLIDING BLAST DOOR MTR 15 A 3 582.0 2666.7 -- -- -- -- 14

11 2666.7 -- -- -- -- 12

9 LTS - EXTERIOR LIGHTING (TYPE C) LTS 20 A 1 216.0 2666.7 3 20 A EQPT ESM-XX 10

7 LTS - EXTERIOR LIGHTING (TYPE D) LTS 20 A 1 204.0 1683.0 1 20 A LTS LGT - INTERIOR LIGHTING 8

5 -- -- -- -- 1100.0 6528.4 -- -- -- -- 6

3 -- -- -- -- 1100.0 7315.0 -- -- -- -- 4

1 EUH-XX EQPT 20 A 3 1100.0 8631.4 3 45 A HVAC;... TA# (PANEL LA#) 2

CKT CIRCUIT DESCRIPTION CLASS TRIP P A B C P TRIP CLASS CIRCUIT DESCRIPTION CKT

Ser…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .