E-007_Revised.pdf

PDF 283 KB Posted

Attached to
Natomas Basin Reach D Levee Improvement Construction Project Federal contract opportunity
Solicitation number
W91238-18-B-0001
Issued by
Department of the Army Corps of Engineers Engineering District Sacramento

About this file

E-007 Revised

View the file

Other files for this federal contract opportunity

Other files attached to Natomas Basin Reach D Levee Improvement Construction Project, newest first.
File Type Posted
B01.01_Abstract_KO_Signed.pdf PDF
21_Mar_18_Final_Bid_Schedule.pdf PDF
G-003_Revised.pdf PDF
00_73_05._Revised.pdf PDF
Plant_4_Program_Requirements_and_Functional_Review_40_95_00_A....pdf PDF
M401_Revised.pdf PDF
W91238-18-B-0001_Amend_0004.pdf PDF
Amend_0004_Comformed.pdf PDF
CD111_Revised.pdf PDF
21_Mar_Specs_Conformed.pdf PDF
A07.1_W9123818B0001_Amend_0003.pdf PDF
W9123818B0001_Amend_0002.pdf PDF
Wage_Determination_CA9_3-2-2018.pdf PDF
KleinfelderBorrowReport.pdf PDF
FinalDDRAppendixD-NatomasReach_D_GDR_100COMPLETE.pdf PDF
No_Additional_Site_Visits.pdf PDF
01_22_00.pdf PDF
A07.01-18B0001_AMD_01.docx.pdf PDF
Exhibit_A_-FinalNatDBidSchedule.pdf PDF
01_45_00.pdf PDF
A07.5_Site_Visit_Attendees.pdf PDF
00_01_15.pdf PDF
A07.7_W91238-18-B-0001_IFB.docx DOCX document
Reach_D_-_B_and_V_Sheets_Final_Dec_05.pdf PDF
Reach_D_Plans_Final_Dec_05.pdf PDF
00_73_05.pdf PDF
Reach_D_Specs.pdf PDF
18_Jan_FinalNatDBidSchedule.pdf PDF
WD_9_Feb_18.pdf PDF
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEW ORLEANS DISTRICT

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

X X

X X :1

A M

E R

IC

A N R

IV

E R C

O M

M O

N F

E A

T U

R E

S

N A

T O

M A B

A S

IN

R

E A

C H D W

IN

D

O W

S

J

V

IT

IT

O E

J P

A S

H A

J

V

IT

IT

O E

S .B

A S

S S

A C

R A

M E

N T

O D

IS

T R

IC

T

S A

C R

A M

E N

T O

C A

-2

J S

T R

E E

T

IN

-H

O U

S E D

E S

IG

N

P U

M P

IN

G P

L A

N T

FINAL SUBMITTAL

D E

C E

M B

E R

NOTES:

CONDUITCABLE

CABLE SCHEDULE

DESCRIPTION

CONDUCTORS/TYPE

CONDUITCABLE

CABLE SCHEDULE

DESCRIPTION

CONDUCTORS/TYPE

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

POWER FROM MCC#1 TO PUMP #1

POWER TO MCC#2 FROM GENERATOR 2

POWER TO MCC#1 FROM GENERATOR 1

POWER FROM MCC#1 TO PUMP #2

POWER FROM MCC#1 TO PUMP #4

POWER FROM MCC#2 TO PUMP #5

POWER FROM MCC#2 TO PUMP #6

POWER FROM MCC#2 TO PUMP #7

UTILITY TO PANEL PP1

(2) 3#350 & 1#1/0 GND/XHHW

(2) 3#350 & 1#1/0 GND/XHHW

(2) 3#350 & 1#1/0 GND/XHHWPOWER FROM MCC#1 TO PUMP #3

(2) 3#350 & 1#1/0 GND/XHHW

(2) 3#350 & 1#1/0 GND/XHHW

(2) 3#350 & 1#1/0 GND/XHHW

(5) 3#600 & 1#350 GND/XHHW

(5) 3#600 & 1#350 GND/XHHW

(2) 3#350 & 1#1/0 GND/XHHW

3 1/2"

3 1/2"

3 1/2"

3 1/2"

3 1/2"

3 1/2"

3 1/2"

1/2"

1/2"

3/4"

POWER FROM MPZ TO LP1

LP1 TO RECEPTACLES

LP1 TO EXHAUST FAN #1

LP1 TO BATT CHARGER #1

LP1 TO BATT CHARGER #2

LP1 TO GENSET #1

LP1 TO GENSET #2

LP1 TO EXHAUST #2

PP1 TO GENSET #1 JACKET HEATER

PP1 TO GENSET #2 JACKET HEATER

PP1 TO MCC1 HEATER

PP1 TO MCC2 HEATER

PP1 TO GENSET #1 WIRING HEATER

PP1 TO GENSET #2 WIRING HEATER

PP1 TO CRANE

3#8, & #10 GND/THHN

3#3, & #10 GND/XHHW

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

2#12, & #12 GND/THHN

3#2, & #8 GND/XHHW

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

''4

''2

1/2"

4"

4"

OTHERWISE NOTED.

LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT UNLESS

CONDUITS ATTACHED TO MOTORS SHALL BE

AND OUTSIDE, SHALL BE PVC COATED RGS.

SHALL BE RIGID GALVANIZED STEEL. CONDUITS,EXPOSED

IN THE CONTROL HOUSE AND GENERATOR BUILDING

CONCRETE WHERE APPLICABLE. CONDUITS INSTALLED

CONCRETE TO PVC COATED RGS ABOVE THE

40 PVC. TRANSITION SCHEDULE 40 PVC CONDUIT IN

2. CONDUITS ENCASED IN CONCRETE SHALL BE SCHEDULE

AND SPECIFICATIONS.

BUT NOT SHOWN WITHIN THE ENTIRE DRAWING SET

AND CABLE INCLUDING ADDITIONAL CABLE REQUIRED

FOR PROVIDING, INSTALLING, AND LABELING ALL WIRE

IN THIS SCHEDULE. THE CONTRACTOR IS RESPONSIBLE

1. ONLY WIRE AND CABLE WITH A CABLE ID IS LISTED

AND SHCEMATIC.

5. SEE SHEET E-009 & E-010 FOR CONTROL WIRING LAYOUT

IN A REINFORCED CONCRETE DUCT BANK.

4. ALL BURIED POWER DISTRIBUTION SHALL BE INSTALLED

EXPANSION FITTING.

FROM DUCT BANK TO ABOVE GRADE SHALL ALSO HAVE AN

TO ANOTHER SHALL HAVE AN EXPANSION FITTING. CONDUIT

STRUCTURES, THE TRANSFER FROM ONE STRUCTURE/SLAB

3. WHERE CONDUITS ARE MOUNTED TO DIFFERENT SLABS/

PG-1

PG-2

P-01

P-02

P-03

P-04

P-05

P-06

P-07

LIGHTING ROWS 1 & 3

LIGHTING ROWS 2 & 4

PU-1

LP1 TO EMERGENCY LIGHT 2#12, & #12 GND/THHN 1/2"

P-10

P-08 POWER FROM MPZ TO LP-S

LP1 TO EXT. GEN. BLDG LIGHTS

LP1-4

LP1-11

LP1-5

LP1-6

LP1-7,9

LP1-8,10

LP1-12

PP1-1,3,5

PP1-2,4,6

PP1-7,9,11

PP1-8,10,12

PP1-13,15,17

PP1-14,16,18

PP1-19,21,23

E1

LP1-14,16 LIGHTING CONTACTOR

LP1-1

LP1-2

LP1-13

2#12, & #12 GND/XHHW 1/2"

E-007

C A

B L E S

C H

E D

U L E

S

E -0

.d g n

1 _ O

L D D

R A

W

IN

G

R E

M O

V E

D F

R O

M S

E T

M A

R

File details come from the government source that posted it.