SECTION J-1 (FACILITY LIST)

WEST POINT FACILITIES 1 2 3 4

FACILITY NAME: West Point ES (old) West Point ES (new) West Point MS West Point Gym INSTALLATION: West Point West Point West Point West Point LOCATION: 705B Barry Road, West Point ,NY 10996 705 Barrry Road, West Point, NY 10996

705 Barry Road, West Point, NY 10996

705C Barry Road, West Point, NY 10996

COUNTY: Orange County Orange County Orange County Orange County FACILITY USE: Pre-K - 4 Pre-K - 4 Grades 5 - 8 Pre-K - 4

GROSS SQUARE FOOTAGE: 59,663 95,552 73,062 14,797

KITCHEN/CAFETERIA? Heat & Serve Only Yes Yes No MULTIPURPOSE ROOM/AUDITORIUM? Yes Yes Yes Yes GYMNASIUM? No No Yes Yes

MAJOR MECHANICAL SYSTEMS: Hot water system. Heated by steam supplied by the post.

Air cooled chiller and natural gas boiiler

Hot water system. Heated by steam supplied by the post.

Roof Mounted AC.

Hot water system. Heated by steam supplied by the post.

Roof mounted AC.

PRIMARY TYPE OF CONSTRUCTION: Block and brick with flat built up roof

Block/Brick with pitched metal roof

Brick veneer with flat built up roof

Block w/ brick veneer and flat built up roof

YEAR OF CONSTRUCTION: 1962; Renovation 1985;

Addition 2005; Demo 2019

Under construction;

Completion Winter 2018

1934; Renovation/Addition 2013 2003

MAINTENANCE SECTIONS

Section C-3 (Mech) Yes Yes Yes Yes Section C-4 (DDC) Yes Yes Yes Yes Section C-5 (Plumbing) Yes Yes Yes Yes Section C-6 (Electrical) Yes Yes Yes Yes Section C-7 (Kitchen Equipment) Yes Yes Yes Yes Section C-8 (Roof Systems & Site) Yes Yes Yes Yes Section C-9 (Building Systems) Yes Yes Yes Yes Section C-10 (Fire Alarm & Suppression) Yes Yes Yes Yes Section C-11 (Playgrounds) Yes Yes Yes Yes

NOTE: The scope of the contract shall include all requisite preventative maintenance, demand maintenance, and repair services, as defined more fully in this Performance Work Statement (PWS) up to the limit of liability ($20,000) for the “Maintenance Sections” indicated above with a “yes.” In addition, the scope of the contract shall include the ability to order on demand maintenance or repair services for requirements above the limit of liability for any “Maintenance Section” indicated above with a “yes.” Also, the contract shall include the ability to order on demand maintenance or repair services for requirements for any amount for those “Maintenance Sections” indicated above by a “no” or to add Sections in their entirety, or portions thereof, for requisite preventive maintenance. Those on demand requirements or “Maintenance Sections” not included in the initial solicitation shall be added by way of bilateral task order or modification.