W911XK20R0011-0003.pdf
PDF 395 KB Posted
- Attached to
- UNION STREET DAM FISH PASS
- Solicitation number
- W911XK20R0011
About this file
This modification amends a solicitation for the Union Street Dam Fish Pass project. The project involves installing a fish passage structure at a dam along with associated water and storm sewer lines. The modification provides remaining questions and answers to offerors, adds specifications for compressed air piping and control systems, revises storm sewer plans, and pre-approves two manufacturers for the pedestrian bridge. Eligible offerors must submit responses by the amended deadline. The soliciting agency is the U.S. Army Corps of Engineers Detroit District. The modification maintains other existing terms and conditions of the solicitation.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W56MES90655862
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to:
a. Provide the remaining Questions and Answ ers
b. Add Addendums to Specifications Sections 10 72 00 and 22 15 14.00 40
c. Add Addendums to Plan Sheets C105 and C209
d. Add Submittal Register
All other terms and conditions remain UNCHANGED.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 27-Jul-2020
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W911XK20R0011
X 9B. DATED (SEE ITEM 11)
19-Jun-2020
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
27-Jul-2020
CODE
U.S.ARMY ENGINEER DISTRICT, DETROIT
477 MICHIGAN AVENUE, 7TH FLOOR
DETROIT MI 48226-4523
W911XK 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W911XK20R0011
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)
The following have been added by full text:
QUESTIONS & ANSWERS AMD 0003
Solicitation No. W911XK20R0011 Amendment 0003
Remaining Questions and Answers:
1. Question: Obermeyer gate indicates a compressor air header. There is no compressed air piping or compressor schedule, please clarify
Government Response: Obermeyer will be providing all the major block components via Government Furnished Materials, however the contractor will be responsible for connecting those items. Buried service compressor piping shall be sch10 welded stainless steel, see amended specification Section 22 15
14.00 40 for pipe and fittings. See amended sheet C105 for approximate route, sizes and length. The obermeyer control panel will be provided by the owner, along with the compressor package and associated valves. Shop drawings of provided equipment and layouts will be available upon contract award.
2. Question: Can you please provide Storm Sewer Profiles that is not shown on page (C -209). For all the proposed storm sewer on this project.
Government Response: See amended sheet C209 for a pipe table for the remaining pipes not shown in profile, for size and length for the purposes of bidding.
3. Question: We have concerns with this river crossing being so short the 278’ of 16” SDR9. With this profile going from an elevation of 590 down to an elevation of 560 and back to an elevation of 591 in such a short distance creates a problem. The bend radius needed on our drill stem would be a 337’ radius. The minimum allowable bend radius for drill stem needed for this size of bore is a 600 ft radius. This is with ideal ground conditions. We are wondering if it is at all possible to lengthen this bore out to at least 375 ft and dig an entry ramp to move the machine farther into the ground to allow for a larger radius?
Government Response: Some accommodations in depth of bury and bore pit dimensions can be accommodated for individual pieces of equipment, however the overall length and alignment of the watermain is not subject to significant changes due to other size and real estate limitations.
If a contractor needs to acquire additional real estate to accommodate different means and methods to install the waterline than the contractor can obtain that real estate in accordance with spec section 01 10 10 at no cost to the government.
4. Question: Pioneer Bridges has submitted company information to be consider for pre-approval as a bidder for the pedestrian bridge.
Government Response: Pioneer Bridges has been pre-approved as a manufacturer for the pedestrian bridge. All other performance and aesthetic requirements for this structure will remain in place. See amended Specification 10 72 00
W911XK20R0011
5. Question: Art Thureson, Inc. has submitted company information to be considered for pre-approval as a bidder for the pedestrian bridge.
Government Response: Art Thureson, Inc. has been pre-approved as a manufacturer for the pedestrian bridge. All other performance and aesthetic requirements for this structure will remain in place. See amended Specification 10 72 00
SECTION 00 10 00 - SOLICITATION
The Issued By organization has changed from
U. S. ARMY ENGINEER DISTRICT, LOUISVILLE
600 MARTIN LUTHER KING JR PLACE
LOUISVILLE KY
to
U.S.ARMY ENGINEER DISTRICT, DETROIT
477 MICHIGAN AVENUE, 7TH FLOOR
DETROIT MI 48226-4523
(End of Summary of Changes)