Register_of_Validated_Testing_Laboratories_27_July_2018.xlsx
XLSX spreadsheet 184 KB Posted
- Attached to
- Lower Rouge River Old Canal Remedial Dredging
- Solicitation number
- W911XK18B0002
About this file
Register of USACE-Validated Testing Laboratories - Version 27 July 2018 - EXCEL FILE
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| US Army Corps of Engineers (USACE) ---- Materials Testing Center (CEERD-GMC) ---- Validated Labortories Register | |
| LAST UPDATE: | 27-Jul-2018 |
For further information or questions on our services or laboratory validation, please contact:
| Brittany Hopkins, MTC Administration and Database Mgr | Chad Gartrell, PE, Director, MTC |
| Brittany.N.Hopkins@usace.army.mil | Chad.A.Gartrell@usace.army.mil |
| 601-634-2142 (office) 601-634-3242 (fax) | 601-634-2313 (office) |
MTC Website: http://www.erdc.usace.army.mil/Media/FactSheets/FactSheetArticleView/tabid/9254/Article/476661/materials-testing-center.aspx
| Validations determined and granted according to Engineer Regulation 1110-1-261 defining the requirement for the Quality Assurance of testing procedures and made by the authority of |
| of ER 1110-1-8100 assigning to the Materials Testing Center, solely, the responsibility to validate commercial laboratories to perform USACE work for CONUS MSCs. |
| Country | State, Territory | City | Validation Status | Company Name | POC | Address | Telephone | Fax | Validation Expiration | AASHTO Accredited? | GAI-GAP Accredited? | Aggregate Test Methods | Bituminous Test Methods | Concrete Test Methods | Masonry, Mortar, and Grout Test Methods | Rock Methods | Soil Test Methods | Sprayed Fire-Resistive Material Test Methods | Other Test Methods Validated | No. of Days to Expiration of Current Validation | |
| United States | Alabama | Andalusia | VALIDATED | CDG Engineers | Jonathan Rhodus | 1840 East Three Notch Street, Andalusia, AL 36420 | (334) 222-9431 | jrhodus@cdge.com | 16-Mar-2019 | Yes | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C511 C1077 C1231 E329 | ASTM D421 D422 D698 D1140 D1556 D1557 D2216 D2487 D2488 D3740 D4318 D6938 E329 | 221 | ||||||||
| United States | Alabama | Birmingham | VALIDATION EXPIRED | Bhate Geosciences | 5217 5th Avenue South Birmingham, AL 35212 | (205)591-7062 | 30-Jun-2018 | Yes | ASTM C117, C127, C128, C136, C566, C702, C1077, and E329. | ASTM D1188, D2041, D2172, D2726, D2950, D3203, D3666, D5444, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C42, C78, C157, C496, C511, C617, C803, C805, C1040, C1077, C1231, and E329. | ASTM C140, C780, and C1019. | ASTM D421, D422, D698, D1140, D1556, D1557, D1883, D2166, D2216, D2487, D2488, D2974, D3740, D4318, D6938, and E329. | ASTM E329, E605, and E736. | -38 | ||||||
| United States | Alabama | Birmingham | VALIDATED | Bowser-Morner, Inc. | 3016 Commerce Square, Birmingham, AL 35210 | (205) 956-8805 | 1-Jun-2020 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C123 C131 C142 C535 C566 C702 C1252 C1260 C1567 D75 D546 D2419 D4791 D5821 D6928 D7428 | ASTM C511 C1260 C1567 | ASTM D421 D698 D1140 D1557 D4318 D6913 | 664 | |||||||||
| United States | Alabama | Birmingham | VALIDATION EXPIRED | Building and Earth Sciences , Inc. | Darrell Gargis | 5545 Derby Drive, Birmingham, AL 35210 | (256) 714-0055 | dgargis@besi.biz | 18-Jul-2018 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 C1077 E329 | ASTM D2041 D2726 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C511 C617 | ASTM D421 D422 D698 D1140 D1143 D1556 D1557 D1883 D2216 D2435 D2487 D2488 D2850 D2974 D3740 D4318 D4546 D4767 D4972 D5084 D6938 E329 | -20 | ||||||
| United States | Alabama | Birmingham | VALIDATION EXPIRES IN < 180 DAYS | Terracon | 110 12TH Street North Birmingham ,AL 35203 | (256) 310-9534 | 10-Nov-2018 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 C1077 D3666 E329 | ASTM D2041 D2172 D2726 D3203 D3666 D5444 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C192 C403 C511 C617 C1077 C1231 E329 | ASTM C1019 | ASTM D558 D698 D854 D1140 D1557 D1883 D2216 D2435 D2487 D2488 D3740 D4318 D4546 D5084 D6938 E329 | 95 | |||||||
| United States | Alabama | Huntsville | VALIDATED | Building and Earth Sciences , Inc. | 2607 Leeman Ferry Rd, Ste. 5&6 Huntsville, AL 35801 | (256) 713-0056 | 14-Jun-2020 | No | ASTM C40 C117 C127 C128 C136 C566 C702 D75 | ASTM D1188 D2041 D2172 D2726 D2950 D3203 D3666 D5444 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C470 C511 C617 C1077 C1231 E329 | ASTM C780 C1019 | ASTM D698 D1140 D1556 D1557 D2216 D2487 D2488 D3740 D4318 D6938 E329 | 677 | |||||||
| United States | Alabama | Huntsville | VALIDATED | GEO Solutions | Matt Barnes | 7201 Opportunity Blvd., Huntsville, AL 35810 | (256) 837-6708 | mbarnes@geo-solutions.net | 29-Jun-2020 | Yes | ASTM C117 C127 C128 C136 C566 C702 C1077 | ASTM D2726 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C511 C617 C1077 C1231 E329 | ASTM DD421 D698 D854 D1556 D1557 D2216 D3740 D4318 D6938 | 692 | ||||||
| United States | Alabama | Huntsville | VALIDATED | OMI, Inc. | 5151 Research Drive NW, Ste. A Huntsville, AL 35805 | 16-Jun-2019 | Yes | ASTM C117, C127, C128, C136, C566, C702, C1077 and D75. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C511, C617, C1077, and C1231. | ASTM D698, D854, D1557, D2216, D3740, D4318, and D6938 | 313 | ||||||||||
| United States | Alabama | Huntsville | VALIDATED | Reed Contracting Services, Inc. | 2512 Triana Boulevard SW Huntsville, AL 35805 | (256) 746-1778 | 21-Jun-2019 | Yes | ASTM C128 C702 C1252 D75 D2419 D4791 | ASTM D140 D979 D995 D2014 D2726 D3203 D3666 D4125 D4867 D5444 D6307 D6925 D6926 D6927 D7113 D727 E329 | 318 | ||||||||||
| United States | Alabama | Huntsville | VALIDATED | S&ME, Inc. | Brian Cooley | 360 D Quality Circle, Huntsville, AL 35806 | (256) 837-8882 | bcooley@smeinc.com | 23-Jan-2020 | Yes | ASTM C117 C127 C128 C136 C566 C702 C1077 D75 E329 | ASTM D2726 D2950 D3666 D5444 D6307 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C157 C192 C511 C617 C642 C1077 C1231 C1542 E329 | ASTM D421 D422 D698 D1140 D1556 D1557 D1883 D2166 D2216 D2487 D3740 D4318 D6938 E329 | 534 | ||||||
| United States | Alabama | Madison | VALIDATION EXPIRES IN < 180 DAYS | Total Solutions, Inc. | 1626 County Line Road, Madison, AL 35758 | (256) 705-0154 | 10-Dec-2018 | No | ASTM C117 C127 C128 C136 C29 C702 C1077 D75 | ASTM C31 C39 C143 C172 C231 C1064 C192 C511 C1077 E329 | ASTM C140 C780 C1019 C1093 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D2216 D2487 D2488 D3740 D4318 D6938 E329 | 125 | ||||||||
| United States | Alaska | Anchorage | VALIDATION EXPIRES IN < 180 DAYS | Alask Testlab (formerly DOWL) | Maria E. Kampsen | 4040B Street Anchorage, AK 99503 | (907) 205-1987 | mkampsen@alaskatestlab.com | 8-Nov-2018 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 C1260 C1567 D75 D2419 D3666 D4791 D5821 E329 | ASTM D2041 D2172 D2726 D2950 D3203 D3666 D4125 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C157 C192 C511 C617 C1077 E329 | ASTM C140 C270 C305 C1093 C1019 C1314 C1437 C1552 | D5240 D5312 D5313 D6473 CRD-C 148 | ASTM D698 D854 D1140 D1557 D2166 D2216 D2419 D2424 D2435 D2487 D2488 D2850 D2974 D3080 D3740 D4253 D4318 D4546 D4767 D5084 D6913 D6938 E329 | E329 E605 E736 | 93 | |||
| United States | Alaska | Anchorage | VALIDATION EXPIRED | Golder Associaties, Inc. | 212 Abbott Road, Ste. 100, Anchorage, AK 99507 | (907) 344-6001 | 10-Nov-2017 | Yes | ASTM C127 | ASTM D421 D422 D698 D854 D1140 D1557 D2166 D2216 D2435 D2487 D2488 D2850 D2974 D3740 D4318 D4718 D4767 D6913 E329 | -270 | ||||||||||
| United States | Alaska | Anchorage | VALIDATION EXPIRED | Hattenburg Dilley and Linnell | 639 West International Drive Anchorage, AK 99503 | (907) 564-2120 | 20-May-2017 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C535 C566 C702 C1077 D2419 D3666 D4791 D5821 E329 | ASTM D2950 D3666 E329 | ASTM C31 C39 C138 C143 C172 C231 C1064 C511 C1077 C1231 E329 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D2216 D2419 D3740 D4791 D5821 E329 | -444 | ||||||||
| United States | Alaska | Anchorage | VALIDATED | Northern Geotechnical Engineering | Ron J.P. Caron | 11301 Olive Lane Anchorage, AK 99515 | 917-344-5934 | afortt@nge-tft.com | 11-Jul-2019 | Yes | ASTM C117, C127, C128, C136, C131, C1077, D2419, D3666, D4791, D5821, and E329 | ASTM D2041, D2726, D3203, D3666, D5444, D6307, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C231, C1064, C192, C511, C1077, C1231, and E329. | ASTM D698, D1140, D1557, D2216, D2419, D2487, D2488, D2974, D3740, D4318, D6938, and E329. | 338 | ||||||
| United States | Alaska | Anchorage | VALIDATED | R&M Consultants, Inc. | 9330 Vanguard Drive, Suite 101 Anchorage, AK 99507 | 29-Sep-2019 | Yes | ASTM C117, C127, C128, C136, C29, C40, C88, C123, C131, C142, C535, C566, C702, C1077, C1252, D75, D546, D3666, D2419, D4791, D5821, and E329. | ASTM D979, D2041, D2172, D2726, D3203, D3666, D4125, D5444, D6307, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C78, C511, C617, C1077, C1231, and E329. | ASTM C780 and C1019. | ASTM D421, D422, D698, D854, D1140, D1556, D1557, D1883, D2166, D2216, D2487, D2488, D2974, D3740, D4318, and D6938, and E329. | 418 | ||||||||
| United States | Alaska | Anchorage | VALIDATED | Shannon and Wilson, Inc. | 5430 Fairbanks Street, Ste.3 Anchorage, AK 99518 | 2-Aug-2019 | Yes | ASTM C117 C127 C128 C136 C40 C566 C702 C1077 D3666 E329 | ASTM D2041 D2726 D3203 D3666 D4125 D5444 D6307 D6936 D6927 E329 | ASTM C31 C39 C138 C143 C172 C231 C1064 C511 C617 C1077 C1231 E329 | ASTM D698 D854 D1557 D2216 D3740 D4318 D6938 E329 | 360 | |||||||||
| United States | Alaska | Fairbanks | VALIDATED | Alask Testlab (formerly DOWL) - Satellite Lab | Maria E. Kampsen | 4040B Street Anchorage, AK 99503 | mkampsen@alaskatestlab.com | 16-May-2019 | No | ASTM C127, C136, C702, and D75. | ASTM D2041, D2726, D3203, D5444, D6307, D6926, and D6927. | ASTM C39, C192, C511, and C1231. | ASTM C109 and C1019. | ASTM D1557, D2168, D2216, D2487, and D6913. | 282 | ||||||
| United States | Alaska | Fairbanks | VALIDATED | Shannon and Wilson, Inc. | 2355 Hill Road, Fairbanks, AK 99709 | (907) 458-3160 | 10-Apr-2020 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 C1252 D75 D546 D2419 D3666 D4791 D5821 E329 | ASTM D2041 D2172 D2726 D3203 D3666 D5444 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C231 C1064 C78 C192 C511 C617 C1077 C1231 E329 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D2216 D2419 D2487 D2488 D2974 D3740 D4318 D4718 D6938 E329 | ASTM E605 and E736. | 612 | |||||||
| United States | Alaska | Kodiak | VALIDATED | Alask Testlab (formerly DOWL) - Satellite Lab | Maria E. Kampsen | 4040 B Street Anchorage, AK 99503 | mkampsen@alaskatestlab.com | 17-May-2019 | No | ASTM C127, C136, C702, and D75.Al | ASTM D2041, D2726, D3203, D5444, D6307, D6926, and D6927. | ASTM C39, C192, C511, and C1231. | ASTM C109 and C1019. | ASTM D1557, D2168, D2216, D2487, and D6913. | 283 | ||||||
| United States | Alaska | North Pole | VALIDATED | Mappa, Inc. | 1956 Richardson Hwy North Pole, AK 99705 | (907) 488-1266 | 28-Feb-2020 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 C1260 C1567 D75 D546 D2419 D3666 D4791 D5821 E329 | ASTM D2041 D2726 D2950 D3203 D3666 D4125 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C192 C617 C1077 C1231 E329 | ASTM C511 C1019 | ASTM D421 D422 D698 D1140 D1556 D1557 D2216 D2487 D2488 D2974 D3740 D4318 D4718 D4972 D6938 E329 | 570 | |||||||
| United States | Alaska | Palmer | VALIDATION EXPIRES IN < 180 DAYS | EMC Engineering, LLC | 5886 E Shop Circle Palmer, AK 99645 | (907) 631-6047 | 20-Oct-2018 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 C1252 D546 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D2041 D2726 D2950 D3203 D3666 D4125 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C231 C1064 C78 C192 C511 C1077 C1231 E329 | ASTM C780 C1019 | ASTM D421 D422 D698 D1140 D1556 D1557 D2216 D2419 D2487 D2488 D2974 D3740 D4318 D6938 E329 | E329 E605 E736 | 74 | ||||||
| United States | Alaska | Palmer | VALIDATION EXPIRES IN < 180 DAYS | HDL Engineering Consultants, LLC | 315 Scott Road Palmer, AK 99645 | 2-Feb-2019 | Yes | ASTM C117, C127, C128, C136, C40, C566, C702, C1077, and D3666. | ASTM D2041, D2172, D2726, D3203, D3666, D5444, D6307, D6926, and D6927. | ASTM C31, C39, C138, C143, C172, C231, C1064, C78, C511, C617, C1077, and C1231. | ASTM D1140, D1557, D2216, D2487, D2488, D3740, D4318, and D6938 | 179 | |||||||||
| United States | American Samoa | Pago Pago | VALIDATED | McConnell Dowell, American Samoa | PO Box 4664 Pago Pago, American Samoa 96799 | 31-Oct-2019 | No | ASTM C117, C127, C128, C136, C29, C40, C566, C702, C1077, D75, D2419, D3744, and D5821. | ASTM D140, D2041, D2726, D2950, D3203, D3665, D3666, D5444, D6307, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C231, C1064, C42, C174, C192, C511, C617, C642, C1077, C1231, and E329 | ASTM C109, C780, and C1019. | ASTM D698, D1140, D1556, D1557, D2216, D2487, D3740, D4318, D4643, D6913, and D6938. | 450 | ||||||||
| United States | Arizona | Chandler | VALIDATION EXPIRES IN < 180 DAYS | ATEK Engineering Consultants, LLC | Michael Connolly | 111 S. Weber Drive, Suite #1 Chandler, AZ 85226 | (602) 291-8828 | mconnolly@atekec.com | 5-Jan-2019 | Yes | ASTM C117, C127, C128, C136, C29, C40, C566, C702, C1077, D75, D2419, D3744, and D5821 | ASTM D140, D2041, D2726, D2950, D3203, D3665, D3666, D5444, D6307, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C231, C1064, C42, C174, C192, C511, C617, C642, C1077, C1231, and E329. | ASTM C109, C780, and C1019. | ASTM D698, D1140, D1556, D1557, D2216, D2487, D3740, D4318, D4643, D6913, and D6938. | 151 | |||||
| United States | Arizona | Gilbert | VALIDATED | Quality Testing, LLC | 175 S. Hamilton Place Bldg. 6, Suite 114 Gilbert, AZ 85233 | 30-May-2019 | Yes | ASTM C117, C127, C128, C136, C29, C40, C88, C123, C142, C566, C702, C1077, D75, D2419, D4791, D5821 and E329. | ASTM D5, D36, D70, D139, D402, D979, D1074, D1188, D2041, D2042, D2170, D2171, D2172, D2726, D2872, D2950, D3203, D3666, D4125, D4867, D5444, D6307, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C42, C78, C174, C192, C495, C511, C617, C1077, C1231, and E329. | ASTM C140. | ASTM D558, D698, D1140, D1556, D1557, D1883, D2166, D2216, D2419, D2435, D2487, D2488, D3080, D3740, D4318, D4546, D4643, D6938, and E329. | 296 | ||||||||
| United States | Arizona | Mesa | VALIDATION EXPIRED | ACS Services, LLC | 2235 West Broadway Rd. Mesa, AZ 85202 | (480) 968-0190 | 16-Mar-2018 | Yes | ASTM C40, C117, C127, C128, C136, C29, C566, C702, C1077, C1252, D2419, D3666, and E329. | ASTM D2041, D2726, D2950, D3203, D3666, D4125, D5444, D6307, D6925, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C42, C78, C511, C617, C1077, C1231, and E329. | ASTM D421, D422, D558, D698, D854, D1140, D1556, D1557, D2216, D2419, D2435, D2487, D3740, D4318, D4546, D4829, D4944, D4972, D6938, and E329. | -144 | ||||||||
| United States | Arizona | Phoenix | VALIDATED | AMEC Environment and Infrastructure, Inc. | 3630 East Wier Ave. Phoenix, AZ 85040 | 2-Aug-2019 | Yes | ASTM C117, C127, C128, C136, C29, C40, C88, C123, C131, C142, C227, C535, C566, C702, C1252, C1260, C1567, D75, D546, D2419, D3744, D4791, and D5821. | ASTM D5, D36, D70, D139, D243, D402, D1074, D1075, D1188, D1461, D1856, D2041, D2042, D2170, D2171, D2172, D2726, D2872, D2950, D3203, D3666, D4125, D4867, D5404, D5444, D6307, D6752, D6925, D6926, D6927, D6931, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C42, C78, C157, C192, C227, C511, C617, C1077, C1231, C1260, D1567, and E329. | ASTM C140, C780, C1019, and C1093. | · ASTM D558, D559, D560, D698, D854, D1140, D1556, D1557, D1883, D2166, D2216, D2434, D2435, D2487, D2488, D2844, D2850, D3080, D3740, D4318, D4546, D4643, D4644, D4767, D4944, D5084, D5731, D6938, and E329. | 360 | ||||||||
| United States | Arizona | Phoenix | VALIDATED | MRM Construction Services | Ramon Lucero | 4806 S 16TH Street, Phoenix, Arizona 85040 | (602) 340-0378 | rlucero@mrmcs.net | 17-Feb-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C142 C566 C702 C1077 C1252 D75 D2419 D3666 D4791 D5821 E329 | ASTM D2041 D2726 D2950 D3203 D3666 D4125 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C143 C172 C173 C231 C1064 C78 C192 C511 C617 C1077 C1231 E329 | ASTM D421 D422 D558 D698 D854 D1140 D1556 D1557 D2216 D2419 D2487 D2488 D3740 D4318 D4944 D4972 D6938 E329 | 194 | ||||||
| United States | Arizona | Phoenix | VALIDATION EXPIRED | Ninyo and Moore | 3202 E Harbour Drive Phoenix, AZ 85034 | (602) 243-1600 | 12-Mar-2017 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 C1252 D2419 D3666 D4791 E329 | ASTM D1074 D2041 D2726 D3203 D3666 D4867 D5444 D6307 D6925 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C192 C617 C1077 C1231 E329 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D2166 D2419 D2435 D2487 D2488 D2850 D2974 D3080 D3740 D4318 D4546 D4767 D4829 D4972 D5084 E329 | ASTM E605 | -513 | |||||||
| United States | Arizona | Phoenix | VALIDATED | Speedie and Associates | Don Cornelison | 3331 E Wood Street, Phoenix, AZ 85040 | (602) 509-9303 | accredit@speedie.net | 2-Jun-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C123 C131 C142 C535 C566 C702 C1077 C1252 D546 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D5 D36 D70 D1074 D1075 D1188 D1461 D1560 D1561 D2041 D2042 D2172 D2726 D2950 D3203 D3666 D4125 D4402 D4867 D5444 D6307 D6390 D6925 D6926 D6927 D6929 D6930 D6931 D6933 D6934 D6935 D6936 D6937 D6997 D6998 D7402 D7496 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C174 C192 C617 C642 C1077 C1231 E329 | C511 C1019 | D7012 | ASTM D558 D698 D854 D1140 D1556 D1557 D1883 D2166 D2216 D2419 D2435 D2487 D2488 D2844 D2974 D3080 D3740 D4318 D4546 D4643 D4718 D4829 D4943 D4944 D4972 D5084 D6938 E329 | 299 | ||||
| United States | Arizona | Phoenix | VALIDATED | Western Technologies, Inc. | 3737 East Broadway Road Phoenix, AZ 85040 | (602) 437-3737 | 2-Mar-2019 | Yes | ASTM C117 C127 C128 C136 C29 C40 C88 C123 C131 C142 C227 C535C566 C702 C1077 C1260 D75 D2419 D3744 D4791 D5821 | ASTM D5 D36 D70 D1074 D1075 D1188 D1856 D2041 D2172 D2726 D2950 D3203 D3666 D4125 D4867 D5444 D6307 D6925 D6926 D6927 | ASTM C31 C39 C138 C143 C172 C173 C231C1064 C42 C78 C157 C192 C511 C1077 C1231 C1260 C1293 C1567 E329 | ASTM C511 | ASTM D421 D422 D558 D698 D1140 D1556 D1557 D1883 D2216 D2419 D2435 D2487 D2488 D3080 D3740 D4318 D4546 D4718 D4829 D4944 D6938 E329 | 207 | |||||||
| United States | Arizona | Sierra Vista | VALIDATION EXPIRED | Western Technologies, Inc. - Satellite Lab at Libby AAF, Ft. Huachuca, AZ | 203 N Canyon Drive, Sierra Vista, AZ 85635 | (520) 458-0364 | 12-Jun-2017 | No | ASTM C117 C136 C702 D75 | ASTM D979, D1074, D1075, D2041, D2726, D2950, D3203, D3666, D4125, D4867, D5444, D6307, D6925, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C231, C1064, C78, C511, C617, C1077, C1231, and E329. | ASTM D421, D698, D1140, D1556, D1557, D2216, D3740, D4318, D4718, D4944, D6938, and E329. | -421 | ||||||||
| United States | Arizona | Tempe | VALIDATED | Alpha Geotechnical & Materials, Inc. | Alf Wold | 2504 W Southern Avenue Tempa, AZ 85282 | (602) 453-3265 | awold@alphageotech.com | 16-Feb-2019 | Yes | ASTM C117, C127, C128, C136, C29, C40, C566, C702, C1077, C1252, D2419, D3666, D4791, D5821, and E329. | ASTM D2041, D2726, D3203, D3666, D5444, D6307, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C511, C617, C1077, C1231, and E329. | ASTM D421, D422, D698, D1557, D2216, D2419, D3740, D4318, D4944, and E329. | 193 | ||||||
| United States | Arizona | Tempe | VALIDATED | ATC Group Services | 9185 South Farmer Avenue, Suite 111 Tempe, Arizona | (480)-894-2056 | 27-Feb-2020 | Yes | ASTM C117, C127, C128, C136, C29, C40, C131, C535, C566, C702, C1077, C1252, D75, D2419, D3666, D4791, D5821, and E329. | ASTM C31 C39 C138 C143 C172 C231 C1064 C42 C192 C511 C617 C1077 E329 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D1883 D2216 D2487 D2488 D3740 D4318 D4643 D5084 D6938 E329 | 569 | |||||||||
| United States | Arizona | Tempe | VALIDATION EXPIRED | Fisher Sand & Gravel Co. dba Southwest Asphalt | 1302 W Drivers Way, Tempe, AZ 85284 | (480) 730-1033 | 16-Jan-2017 | Yes | ASTM C40 C117 C123 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 C1260 D75 D546 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D979 D1074 D1075 D1188 D2041 D2726 D2950 D3203 D3666 D4125 D4867 D5444 D6307 D6925 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C157 C172 C173 C231 C1064 C42 C78 C174 C192 C293 C403 C511 C617 C1077 C1231 E329 | ASTM C140 C1093 | ASTM D421 D422 D558 D559 D560 D698 D854 D1140 D1556 D1557 D1883 D2166 D2216 D2435 D2487 D2488 D3740 D4318 D4944 D4972 D6938 E329 | ASTM E605 | -568 | ||||||
| United States | Arizona | Tempe | VALIDATED | Terracon | 4685 South Ash Avenue, Suite H-4 Tempe, AZ 85282 | (480) 897-8200 | 20-Mar-2020 | Yes | ASTM C40, C117, C127, C128, C136, C29, C88, C123, C131, C142, C535, C566, C702, C1077, C1252, C1260, C1567, D546, D2419, D3666, D3744, D4791, D5821, and E329. | ASTM D2041, D2726, D2950, D3203, D3666, D4125, D4867, D5444, D6307, D6925, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C42, C78, C157, C192, C511, C617, C1077, C1231, C1260, C1567, and E329. | ASTM C140 and C1093. | ASTM D421, D422, D558, D559, D560, D698, D854, D1140, D1556, D1557, D1883, D2166, D2216, D2419, D2435, D2487, D2488, D2844, D2974, D3080, D3740, D4318, D4643, D5084,E329. | 591 | |||||||
| United States | Arizona | Tucson | VALIDATION EXPIRES IN < 180 DAYS | Conforma Tech, Inc. | Jon Hoffman | 1425 E. Apache Park Pl. Tucson, AZ 85714 | (520)573-2045 | jon.hoffman@conformatech.com | 9-Dec-2018 | Yes | ASTM C40, C117, C127, C128, C136, C29, C142, C566, C702, C1077, D2419, D3666, and E329. | ASTM D2041, D2726, D3203, D3666, D5444, D6307, D6926, D6927, and E329. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C511, C617, C1077, C1231, and E329. | ASTM D698, D1140, D1557, D2216, D2419, D3740, D4318, and E329. | 124 | ||||||
| United States | Arizona | Tucson | VALIDATED | Pattison Engineering, LLC | 1129 N. Winstel Blvd. Tucson, AZ 85716 | (520) 881-1234 | 30-Aug-2019 | Yes | ASTM C117 C136 | ASTM D698 D1140 D1557 D2216 D3740 D4318 | 388 | ||||||||||
| United States | Arizona | Tucson | VALIDATION EXPIRES IN < 180 DAYS | Smith and Annala Engineering Company | 3860 S. Palo Verde Road, Suite 315 Tucson, AZ 85714 | (520) 203-8257 | 3-Jan-2019 | Yes | ASTM C117, C127, C128, C566, and C702. | ASTM C31, C39, C138, C143, C172, C1064, C511, and C1231. | ASTM D421, D698, D1140, D1557, D2216, D2487, D4318, D4643, D4944, and D6938. | 149 | |||||||||
| United States | Arizona | Tucson | VALIDATED | Speedie and Associates | 3125 E 47th street, Tucson, AZ 85713 | (602) 509-9303 | 11-Jul-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C131 C535 C566 C702 C1077 C1252 D2419 D3666 D4791 D5821 E329 | ASTM D2041 D2726 D3203 D3666 D4125 D5444 D6307 D6925 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C174 C192 C511 C617 C642 C1077 C1231 E329 | ASTM D698 D854 D1556 D1557 D2216 D2419 D2435 D2487 D2488 D3740 D4318 D4546 D4944 D4972 D6938 E329 | 338 | ||||||||
| United States | Arizona | Tucson | VALIDATED | Western Technologies, Inc. | 3480 South Doge Blvd., Tucson, AZ | 29-Sep-2019 | Yes | ASTM C117 C127 C128 C136 C29 C40 C88 C123 C131 C142 C535 C702 C1077 C1252 D75 D2419 D4791 D5821 E329 | ASTM D1188 D2041 D2726 D3203 D3666 D4125 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C192 C511 C1077 C1231 E329 | ASTM C140 C780 C1019 C1093 C1314 C1552 | ASTM D421 D422 D558 D698 D1556 D1557 D1883 D2216 D2419 D3740 D2487 D2488 D4318 D4718 D4829 D4944 D6938 E329 | 418 | ||||||||
| United States | Arizona | Yuma | VALIDATED | Goetechnical Testing Services, Inc. | Mr. Courtney Arviso | 1044 E. 21st Street, Yuma, AZ 85365 | (928) 329-4695 | carviso@arvisoengineering.com | 9-Jan-2020 | Yes | ASTM C117, C127, C128, C136, C29, C39 C40, C131, C142, C174, C566, C702, C1077, C1252, D2419, D3666, D4791, D5821, and E329 | ASTM D2041, D2726, D3203, D3666, D4125, D5444, D6307, D6926, D6927, and E329 | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C78, C192, C511, C617, C1077, C1231, and E329 | ASTM C1019 | ASTM D698, D1140, D1556, D1557, D2216, D3740, D4318, D6938, and E329 | 520 | |||||
| United States | Arizona | Yuma | VALIDATED | NEI Geotechnical | 1851 W 24th Street Yuma, AZ 85364 | (928) 344-8844 | 30-May-2019 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 C1077 D2419 D3666 E329 | ASTM D2041 D2726 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C231 C1064 C78 C511 C1077 C1231 E329 | ASTM D421 D422 D698 D1140 D1556 D1557 D2216 D2419 D2487 D2488 D3740 D4318 D4944 D6938 E329 | 296 | ||||||||
| United States | Arkansas | Fayetteville | VALIDATION EXPIRED | GTS, Inc. | 1915 N Shiloh Drive, Ste. 1 Fayetteville, AR 72704 | (479) 521-7465 | 21-Jul-2018 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C142 C566 C702 C1077 C1252 D2419 D4791 E329 | ASTM D1188 D2726 D2950 D3666 E329 | ASTM C31 C39 C138 C143 C172 C231 C1064 C42 C78 C511 C617 C1077 C1231 E329 | ASTM C780 C1019 | ASTM D421 D422 D558 D854 D1140 D1557 D1883 D2216 D2419 D2487 D2974 D3740 D4318 D4972 D5084 D6938 E329 | -17 | |||||||
| United States | Arkansas | Little Rock | VALIDATION EXPIRED | Anderson Engineering Consultants, Inc. | 10205 West Rockwood Road, Little Rock, AR 72204 | (501) 455-4545 | 9-Jul-2018 | No | ASTM C40 C117 C127 C128 C136 C88 C131 C535 C702 C1077 D75 | ASTM D2041 D2172 D2726 D3666 D5444 E329 CRD-C650 | ASTM C31 C39 C138 C143 C172 C231 C1064 C42 C78 C192 C470 C511 C617 C1077 E329 | ASTM C140 C780 C1019 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D1883 D2166 D2216 D2487 D3740 D4318 D6938 E329 | -29 | |||||||
| United States | Arkansas | Little Rock | VALIDATED | Grubbs, Hoskyn, Barton, and Wyatt, Inc. | #1 Trigon Place Little Rock, AR 72209 | (501) 455-2536 | 7-Feb-2019 | Yes | ASTM C40 C117 C127 C128 C136 C88 C131 C566 C702 C1077 D3666 | ASTM D2041 D2726 D3203 D3666 D4125 D5444 D6307 D6925 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C511 C617 C1077 C1231 E329 | ASTM C109 C185 C270 C305 C1093 C1437 C1506 | ASTM D421 D422 D698 D1140 D1557 D1883 D2216 D3740 D4318 D6938 E329 | 184 | |||||||
| United States | Arkansas | Little Rock | VALIDATION EXPIRES IN < 180 DAYS | Materials Testing of Arkansas, Inc. | P O Box 23715 Little Rock, AR 72221 | (501) 753-2526 | 15-Aug-2018 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 C1077 | ASTM D2041 C2726 C3203 C3666 C5444 D6307 D6925 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C511 C617 C1077 E329 | ASTM D421 D698 D1557 D2216 D2419 D3740 D4318 D6938 E329 | 8 | ||||||||
| United States | Arkansas | Little Rock | VALIDATION EXPIRED | W2 Engineering - Satellite Lab | Little Rock Air Force Base, Little Rock, AR | 8-Jul-2017 | No | ASTM C117 C136 C702 D75 | ASTM C31 C39 C138 C143 C172 C231 C1064 C78 C47 C511 C1077 | ASTM D1556 D1557 D3740 D4318 D6938 E329 | -395 | ||||||||||
| United States | Arkansas | Springdale | VALIDATED | Grubbs, Hoskyn, Barton, and Wyatt, Inc. | Dr. Subra T. Bhat, PhD, PE | 341 West County Line Road, Springdale, AR 72764 | (479)756-5999 | sbhat@grubbsengineering.com | 23-Jan-2020 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 C1077 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C511 C617 C1077 C1231 | ASTM D698 D1140 D1557 D2216 D3740 D4318 D6938 | 534 | |||||||
| United States | Arkansas | Texarkana | VALIDATED | ETTL Engineers and Consultants, Inc. | Mr. Chavin Caraway | 210 Beech Street, Texarkana, AR 71854 | (870) 772-0013 | 15-Nov-2020 | No | ASTM C117, C127, C128, C136, C29, C40, C566, C702 and D75 | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C42, C78, C174, C192, C470, C511, C617, C1231 | ASTM C109, C140, C1019 | ASTM D558, D698, D1140, D1556, D1557, D2168, D2216, D2487, D4318, D6913, D6938 | 831 | |||||||
| United States | California | Anaheim | VALIDATION EXPIRED | Group Delta Consultants, Inc. | 1320 Simpson Circle, Anaheim, CA 92806 | (714) 660-7500 | 17-Nov-2017 | Yes | ASTM C40 C117 C127 C128 C136 C29 C142 C566 C702 C1077 D546 D2419 D3666 D3744 E329 | ASTM D1188 D1560 D1561 D2041 D2726 D2950 D3203 D3666 D5444 D6307 D6925 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C174 C192 C293 C617 C1077 C1231 E329 | ASTM D421 D422 D1140 D1556 D1557 D2216 D2419 D2487 D2844 D3740 D4318 D4829 D6938 E329 | -263 | ||||||||
| United States | California | Anaheim | VALIDATION EXPIRES IN < 180 DAYS | MTGL, Inc. | Michael Landon | 2992 E. La Palma Avenue, Ste. A Anaheim, CA 92806 | (714) 632-2999 | mlandon@mtglinc.com | 17-Jan-2019 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 C1077 D3666 D75 D2419 D3744 D4791 D5821 E329 | ASTM D1560 D1561 D2041 D2726 D2950 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C192 C511 C617 C1077 C1231 E329 | ASTM C140 | ASTM D421 D1140 D2216 D2419 D2844 D3740 4318 D6938 E329 | 163 | |||||
| United States | California | Apple Valley | VALIDATED | Merrell Engineering Company, Inc. | Clayton Garrison | 16091 Kamana Road, Apple Valley, CA 92307 | (760) 256-2068 | clayton.garrison@merrelljohnson.com | 19-Apr-2020 | Yes | ASTM C29 C40 C117 C136 C566 C702 D3666 D75 D2419 D5821 | ASTM D979 D1560 D1561 D2726 D2950 D3203 D6307 D6926 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C511 C617 C1077 C1231 E329 | ASTM C511 C1019 | ASTM D698 D1140 D1556 D1557 D2216 D2487 D2937 D3740 D4318 D6938 E329 | 621 | |||||
| United States | California | Bakersfield | VALIDATED | BSK Associates | 700 22nd Street Bakersfield, CA 93301 | (661) 327-0671 | 14-Sep-2019 | Yes | ASTM C117 C127 C128 C136 C29 C40 C566 C702 C1077 D75 D2419 E329 | ASTM D2041 D2726 D2950 D3203 D3666 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C511 C617 C1077 C1231E329 | ASTM D698 D854 D1140 D1556 D2216 D2419 D2487 D2488 D2850 D3740 D4318 D6938 E329 | 403 | ||||||||
| United States | California | Chico | VALIDATED | Holdrege & Kull | Chad Borean | 48 Bellarmine Court, Chico, CA 95928 | 530-894-2487 | cborean@handk.net | 22-Jan-2020 | yes | ASTM C117 C127 C128 C136 C29 C40 C142 C566 C702 C1077 D2419 D3666 D3744 D5821 E329 | ASTM D3666 E329 | ASTM C31 C39 C138 C143 C172 C231 C1064 C192 C511 C617 C1231 | ASTM D698 D1140 D1556 D1557 D2166 D2216 D2487 D2488 D2850 D2937 D4318 D4767 D5084 D6938 | ASTM E329 E605 E736 | 533 | |||||
| United States | California | El Dorado Hills | VALIDATED | Youngdahl Consulting Group, Inc. | Jeffry Cannon | 1234 Glenhaven Court, El Dorado Hills, CA 95762 | (916) 933-0633 | jlc@youngdahl.net | 1-Mar-2020 | Yes | ASTM C40 C117 C127 C128 C136 C29 C131 C535 C566 C702 D75 D2419 D3744 D4791 D5821 | ASTM D1188 | ASTM C31 C39 C138 C143 C172 C173 C192 C231 C1064 C511 C617 C1077 C1231 C1542 C1604 | ASTM C140 C780 C1019 C1093 C1314 C1552 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D2166 D2216 D2435 D2487 D2488 D3080 D3740 D4318 D4546 D4643 D5084 D6913 D6938 | ASTM E605 and E736 | 572 | ||||
| United States | California | Escondido | VALIDATION EXPIRES IN < 180 DAYS | Construction Testing and Engineering, Inc. | 1441 Montiel Road, Ste. #115 Escondido, CA 92026 | (760) 746-4955 | 21-Sep-2018 | Yes | ASTM C40 C117 C127 C128 C136 C131 C535 C566 C702 C1077 D2419 D3666 D75 E329 | ASTM D1560 D1561 D2041 D2726 D2950 D3203 D3666 D4867 D54444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C192 C511 C617 C1077 C1231 E329 | ASTM C140 C1019 C1093 C1314 C1552 | ASTM D421 D422 D698 D1140 D1556 D1557 D2216 D2419 D2435 D2487 D2488 D2844 D3740 D4318 D4643 D4829 D6938 E329 | 45 | |||||||
| United States | California | Fremont | VALIDATED | CTE Cal, Inc. | Rod Ballard | 46716 Fremont Blvd. Fremont, CA 94538 | (510) 573-6362 | rod.ballard@ctecal.com | 17-Apr-2019 | Yes | ASTM C117 C127 C128 C136 C40 C566 C702 C1077 D2419 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C511 C617 C1077 C1231 E329 | ASTM D698 D854 D1140 D1557 D2216 D2419 D2487 D2488 D3740 D4318 D4643 D4972 D6938 E329 | 253 | |||||||
| United States | California | Fresno | VALIDATED | Moore Twinning Associates, Inc. | 2527 Fresno Street, Fresno, CA 93721 | 559-268-7021 | 1-Mar-2020 | Yes | ASTM C40 C117 C127 C128 C136 C29 C40 C70 C88 C123 C131 C142 C535 C566 C1077 C3666 D75 D2419 D4791 D5821 E329 | ASTM D1188 D1560 D1561 D2041 D2172 D2726 D2950 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C157 C174 C192 C293 C511 C617 C1077 C1231 E329 | ASTM C140 C1093 | ASTM D421 D422 D558 D698 D854 D1140 D1556 D1557 D1883 D2166 D2216 D2435 D2487 D2974 D3080 D3740 D4318 D4643 D5084 D6938 E329 | 572 | |||||||
| United States | California | Fresno | VALIDATED | RMA Geoscience, Inc. | 3897 N Ann Avenue Fresno, CA 93727 | 29-Mar-2019 | Yes | ASTM C117, C127, C128, C136, C40, C566, C702, C1077, D2419, D3744, and E329 | ASTM D1188, D2041, D2726, D2950, D3203, D5444, and D6307 | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C511, C617, C1077, C1231, and E329 | ASTM C140 and C1552 | ASTM D698, D1140, D1556, D1557, D2216, D2419, D4318, D4829, D4944, D6913, and D6938 | ASTM E605 and E736 | 234 | |||||||
| United States | California | Fresno | VALIDATED | Technicon Engineering Services, Inc. | 4539 N Brawley #108, Fresno, CA 93722 | (559) 276-9311 | 18-Oct-2019 | Yes | ASTM C117 C127 C128 C136 C29 C88 C123 C142 C566 C702 C1077 D75 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D979 D1560 D1561 D2041 D2726 D2950 D3203 D3666 D4867 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C157 C192 C511 C617 C805 C1077 C1231 E329 | ASTM C140 C1019 C1093 | ASTM D421 D422 D698 D1140 D1557 D2166 D2216 D2419 D2435 D2487 D2488 D2844 D2850 D2974 D3080 D3740 D4318 D4829 D6938 E329 | ASTM E605 E736 | 437 | ||||||
| United States | California | Grass Valley | VALIDATED | Geo-Logic Associates | 143E Spring Hill Drive Grass Valley, CA 95945 | (530) 272-2448 | 20-Mar-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C131 C142 C702 D2419 D3744 | ASTM C31 C39 C138 C143 C172 C231 C1064 C511 C1077 C1231 E329 | ASTM D421 D422 D698 D854 D1140 D1556 D1557 D2166 D2216 D2419 D2435 D2487 D2488 D2850 D2974 D3080 D3740 D4318 D4546 D4718 D4767 D4832 D5084 D5731 D6913 D6938 E329 | 225 | |||||||||
| United States | California | Hayward | VALIDATED | Kleinfelder West | 2601 Barrington Court Hayward, CA 94545 | (925) 484-1700 | 29-Sep-2019 | Yes | ASTM C117 C127 C128 C136 C29 C40 C88 C123 C131 C142 C535 C566 C702 C1007 C1252 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D1074 D1075 D1560 D1561 D2041 D2172 D2726 D3203 D4867 D5444 D6307 D6390 D6925 D6926 D6927 D3666 E29 | ASTM C31 C39 C42 C78 C138 C143 C157 C172 C173 C192 C227 C231 C469 C496 CD511 C617 C642 C1064 C1231 C1260 C1293 C1567 C1077 E329 | ASTM D421 D422 D698 D854 D1140 D1557 D2166 D2216 D2419 D2435 D2487 D2488 D2844 D2850 D2974 D3080 D3740 D4318 D4546 D4643 D4767 D4829 D4972 D5084 E329 | ASTM E329 E605 | 418 | |||||||
| United States | California | Hayward | VALIDATED | Signet Testing Laboratories, Inc. | 3526 Breakwater Court, Hayward, CA 94545 | 6-Apr-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C142 C566 C702 C1252 D546 D2419 D3666 E329 | ASTM D1560 D1561 D2041 D2726 D3203 D3666 D4867 D5444 D6307 D6926 D6927 E329 | ASTM C31 C398 C138 C143 C172 C173 C231 C164 C78 C192 C511 C617 C1077 C1231 E329 | ASTM D421 D422 D558 D559 D698 D854 D1140 D1557 D1883 D2166 D2216 D2419 D2435 D2487 D2488 D2844 D2850 D2974 D3740 D4318 D4546 D4767 D5084 D6938 E329 | 242 | |||||||||
| United States | California | Irwindale | VALIDATION EXPIRED | Sully-Miller Contracting Company | 2600 Avenida Basbosa, Irwindale, CA 91706 | (714)-240-1584 | 7-Jun-2018 | Yes | ASTM C117, C127, C128, C136, C29, C88, C131, C566, C702, C1252, D75, D546, D2419, D3666, D3744, D4791, and D5821 | ASTM D1074, D1075, D1188, D1560, D1561, D2041, D2726, D2950, D3203, D3666, D4867, D5444, D6307, D6925, D6926, D6927, and E329 | ASTM D698, D1556, D1557, D2419, D3740, D6938, and E329. | -61 | |||||||||
| United States | California | La Habra | VALIDATED | Hushmand Associates, Inc. | 1271 E. Lamber Rd. Suite B La Habra, CA 90631 | (949) 777-1266 | 18-Jul-2020 | Yes | ASTM C31 C39 C138 C143 C172 C231 C511 C1064 C1077 C1231 | ASTM D421 D422, D698, D854, D1140, D1556, D1557, D2216, D2419, D2435, D2487, D2488, D2850, D3080, D3740, D4318, D4546, D4767, D5084, D6913, D6938, and E329 | 711 | ||||||||||
| United States | California | Lancaster | VALIDATION EXPIRED | Arrow Infrastructure Solutions, Inc. dba Arrow Engineering | 42138 Tenth Street West Lancaster, CA 93534 | (661) 949-2525 | 9-Oct-2017 | Yes | ASTM C40 C117 C127 C128 C136 C29 C566 C702 C1077 D75 D2419 D4791 E329 | n | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C511 C617 C1077 C1231 E329 | ASTM D421 D422 D698 D1140 D15556 D1557 D2216 D2419 D2435 D2487 D2488 D3740 D4318 D4643 D6938 E329 | -302 | ||||||||
| United States | California | Lancaster | VALIDATION EXPIRES IN < 180 DAYS | Krazan & Associates, Inc. | 42326 10th Street West Lancaster, CA 93534 | 29-Sep-2018 | Yes | ASTM C117, C127, C128, C136, C29, C40, C142, C566, C702, D75, D2419, and D3666 | ASTM D2041, D2172, D2726, D2950, D3666, D5444, D6926, and D6927 | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C78, C511, C617, C1077, C1231, and E329 | ASTM D421, D422, D558, D854, D1140, D1556, D1557, D2216, D3740, D4318, and D6938 | 53 | |||||||||
| United States | California | Lathrop | VALIDATED | ENGEO, Inc. | 17278 Golden Valley Parkway Lathrop, CA 95330 | 28-Feb-2019 | Yes | ASTM C117, C127, C128, and C136 | ASTM D698, D854, D1140, D1557, D2166, D2216, D2435, D2487, D2488, D2850, D3080, D3740, D4318, D4546, D6913 and E329 | 205 | |||||||||||
| United States | California | Livermore | VALIDATED | BSK Associates | 324 Earhart Way Livermore, CA 95377 | 17-Feb-2019 | No | ASTM C117, C127, C128, C136, C29, C40, C566, C702, C1077, D75, 2419, and E329. | ASTM D2041, D2726, D2950, and D3203 | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C78, C511, C617, C1077, C1231, and E329. | ASTM C140, C1019 and C1093. | ASTM D421, D422, D698, D854, D1140, D1556, D1557, D2216, D2419, D2487, D2488, D2850, D3740, D4318, D6938, and E32 | 194 | ||||||||
| United States | California | Lodi | VALIDATION EXPIRES IN < 180 DAYS | Terracon Consultants, Inc. | Joe Edwards | 902 Industrial Way, Lodi, CA 95240 | (209) 367-3701 | joe.edwards@terracon.com | 19-Aug-2018 | Yes | ASTM C117, C127, C128, C136, C566, C702, C1077, D75, D2419, D3666, D3744, D4791, D5821, and E329 | ASTM D1561, D2041, D2726, D3203, D3666, D4867, D5444, D6307, E329, and AASHTO T275 and T324 | ASTM C31, C39, C138, C143, C172, C231, C1064, C42, D511, C617, C1077, C1231, and E329. | ASTM D421, D422, D698, D854, D1140, D1557, D2166, D2216, D2435, D2487, D2488, D2974, D3740, D4318, D4643, and E329 | 12 | ||||||
| United States | California | Long Beach | VALIDATION EXPIRES IN < 180 DAYS | Twining, Inc. | 3310 E Airport Way, Long Beach, CA 90806 | 3-Feb-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C70 C88 C131 C142 C289 C535 C566 C702 C1260 C1567 D75 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D1560 D1561 D2041 D2172 D2726 D2950 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C109 C151 C157 C174 C183 C185 C187 C188 C191 C192 C204 C266 C305 C311 C403 C430 C441 C451 C469 C495 C496 C511 C512 C567 C617 C642 C805 C827 C939 C989 C1012 C1038 C1090 C1077 C1140 C1202 C1231 C1437 C1260 C1293 C1506 C1542 C1567 C1609 E329 | ASTM C109 C140 C185 C270 C305 C511 C780 C1093 C1019 C1314 C1437 C1506 C1552 | ASTM D698 D1556 D1557 D2216 D2419 D2487 D2488 D3740 D4829 D6938 E329 | E605 E736 | Metals: ASTM A123-A90 A185 A185-A370 A325-E-18 A325-F606 A416-A1061 A496 A416-A1061 A496-A370 A4971 A497-A370 A615-A1034 A615 A370 A615-E290 A706-A1034 A706-A370 A706-E290 A709-E23 A741-A370 A775 A82 A82-A370 A970 A970-A370 A996-A1034 A996-370 A996-E328 | 180 | ||||||
| United States | California | Los Angeles | VALIDATED | Smith-Emery of San Francisco, Inc. | 781 E Washington Blvd. Los Angeles, CA 90021 | (213) 749-3411 | 14-Aug-2019 | Yes | ASTM C117 C127 C128 C136 C29 C40 C88 C131 C142 C535 C566 C702 C1077 D75 D2419 D3744 E329 | ASTM C39 C78 C511 C617 | ASTM D698 D854 D1140 D2166 D2216 D2419 D2435 D2487 D3080 D4318 | 372 | |||||||||
| United States | California | Los Angeles | VALIDATED | USACE Prado Dam Quality Assurance Laboratory | 915 Wilshire Blvd. Los Angeles, CA 90017 | 24-Jun-2019 | No | ASTM C117, C127, C128, C136, C29, C40, C131, C142, C535, C566, C702, C1077, D75, and D2419 | ASTM D2940 | ASTM C31, C39, C138, C143, C172, C231, C1064, C192, C470, C511, C617, C1077, C1231, and E329 | ASTM D421, D422, D558, D698, D854, D1140, D1556, D1557, D1883, D1632, D1633, D2166, D2168, D2216, D2435, D2487, D2850, D3080, D3740, D4318, D4767, D4829, D5084, D6467, D6913, D6938, D7608, and E329 | 321 | |||||||||
| United States | California | Maryville | VALIDATION EXPIRES IN < 180 DAYS | MHM, Inc. | John Mallen | 1204 E Street Maryville, CA 95901 | 530-742-6485 | jmallen@mhm-inc.com | 10-Nov-2018 | Yes | ASTM D698 D1556 D1557 D2216 D2487 D2488 D3740 D4318 D4829 D6938 E329 | 95 | |||||||||
| United States | California | Moreno Valley | VALIDATED | United Testing Corp. dba United-Heider Inspection Group | Steve Lindquist | 22620 Goldencrest Drive, Ste. 114, Moreno Valley, CA 92553 | (951) 697-4777 | slindquist@uit-inc.us | 21-Feb-2019 | Yes | ASTM C117, C127, C128, C29, C40, C131, C142, C535, C702, and D2419. | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C511, C617, C1077, C1231, and E329 | ASTM C140, C1019, C1314, and C1552 | ASTM D698, D1556, D1557, D2216, D2419, D2487, D2488, and D6938 | ASTM E605 and E736. | 198 | |||||
| United States | California | Murphys | VALIDATED | Micro-Chem Laboratories | 635 Bret Harte Drive Murphys, CA 95247 | (209) 728-8200 | 6-Mar-2019 | No | ASTM C88 C295 C702 D75 D3740 CRD-C130 | ASTM C856 | ASTM D5312 D5313 | 211 | |||||||||
| United States | California | North Highlands | VALIDATED | Consolidated Engineering Laboratories | Mr. Dan Allopenna | 5304 Roseville Road, Ste. K. North Highlands, CA 95660 | (916) 343-6995 | jp@ce-labs.com | 9-Jan-2020 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 C1077 D2419 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C511 C617 C1077 C1231 E329 | ASTM C1019 | ASTM D421 D698 D1140 D1557 D2216 D3740 D4318 D6938 E329 | ASTM E329 E605 E736 | 520 | |||||
| United States | California | North Highlands | VALIDATION EXPIRES IN < 180 DAYS | CTE Cal, Inc. | Kristin Kohls | 3628 Madison Avenue, Ste. 22, North Highland, CA 95660 | (916) 331-6030 | kristin.kohls@ctecal.com | 3-Feb-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 D2419 D3666 D4791 D5821 E329 | ASTM D2041 D2726 D2950 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 1C38 C143 C172 C173 C231 C1064 C42 C78 C157 C174 C192 C469 C511 C512 C617 C1077 C1231 E329 | ASTM C140 C1019 C1093 C1552 | ASTM D421 D422 D698 D1140 D1556 D1557 D2216 D2419 D2487 D2488 D2844 D3740 D4318 D4829 D6938 E329 | 180 | |||||
| United States | California | Oakland | VALIDATED | Consolidated Engineering Laboratories | 534 23rd Ave. Oakland, California 94606 | (510) 436-7626 | 21-Feb-2019 | Yes | ASTM C117 C127 C128 C136 C29 C131 C535 C566 C702 D75 D2419 E329 | ASTM D1074 D1560 D1561 D2041 D2726 D2950 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C511 C617 C1077 C1231 E329 | ASTM C140 C1019 C1093 C1314 C1552 | ASTM D421 D698 D1140 D1557 D2216 D2419 D2844 D3740 D4318 D6938 E329 | ASTM E605 E736 | 198 | ||||||
| United States | California | Ontario | VALIDATED | Kleinfelder | Jeffrey Diaz | 620 South Magnolia Ave. Ontario, CA 91762 | (909)-657-1716 | jmdiaz@kleinfelder.com | 28-Mar-2020 | Yes | ASTM C117 C127 C128 C136 C29 C88 C131 C142 C535 C566 C702 C1077 D75 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D2041 D2726 D2950 D3203 D3666 D4867 D5444 D6307 E329 | ASTM C31 C39 C138 C143 C157 C172 C173 C231 C1064 C42 C78 C174 C192 C511 C617 C1077 C1231 C1542 E329 | ASTM C140 C780 C1019 C1093 | ASTM D421 D422 D558 D698 D1140 D1556 D1557 D2166 D2216 D2435 D2487 D2488 D3080 D3740 D4318 D6938 E329 | E329 E605 E736 | 599 | ||||
| United States | California | Orange | VALIDATED | Sequoia Consultants, Inc. | 361 W. Grove Avenue Orange, CA 92865 | (714) 974-6316 | 29-Sep-2019 | Yes | ASTM C117 C127 C128 C136 C40 D2419 D3666 D3744 D4791 E329 | ASTM D1560 D1561 D2041 D2172 D2726 D2950 D3203 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C192 C231 C511 C617 C1064 C1077 C1231 E329 | ASTM D558 D559 D698 D1140 D1556 D1557 D2166 D2419 D2488 D2844 D4318 D6938 E329 | 418 | ||||||||
| United States | California | Oxnard | VALIDATED | CTE South, Inc. | 1645 Pacific Avenue Oxnard, CA 93033 | (805) 486-6475 | 29-May-2020 | Yes | ASTM C117 C127 C128 C136 C566 C702 C1077 D2419 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C511 C617 C1077 C1231 | ASTM D421 D698 D1556 D1557 D2216 D2487 D3740 D4318 D6938 | 661 | |||||||||
| United States | California | Palmdale | VALIDATION EXPIRED | Earth Systems Southern California | 1024 West Avenue M4 Palmdale, CA 93534 | (661) 948-7538 | 3-Feb-2018 | Yes | ASTM C40 C117 C127 C128 C136 C88 C131 C142 C535 C566 C702 C1077 D75 D2419 D3666 E329 | ASTM D1188 D1560 D1561 D2041 D2172 D2726 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C192 C617 C1077 C1231 E329 | ASTM D421 D422 D698 D1140 D1556 D1557 D1883 D2216 D2419 D2487 D2488 D2844 D3740 D4318 D6938 E329 | -185 | ||||||||
| United States | California | Palo Alto | VALIDATED | Cooper Testing Labs, Inc. | 937 Commercial Street, Palo Alto, CA 94303 | (650) 213-8436 | 30-Aug-2019 | Yes | ASTM C127 | ASTM D4644 D5731 | ASTM D422 D698 D854 D1140 D1557 D1883 D2166 D2216 D2434 D2435 D2487 D2844 D2850 D3080 D3740 D4318 D4546 D4767 D4829 D5084 G57 | 388 | |||||||||
| United States | California | Pleasanton | VALIDATION EXPIRES IN < 180 DAYS | Krazan & Associates, Inc. | 1061 Serpentine Lane Suite F Pleasanton, CA 94566 | (925)307-1160 | 1-Sep-2018 | Yes | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C511, C617, C1077 and C1231 | ASTM D421, D698, D1140, D1557, D2216, D2487, D3740, D4318, and D6938. | 25 | ||||||||||
| United States | California | Racho Cordova | VALIDATION EXPIRES IN < 180 DAYS | Geocon Consultants, Inc. | 3160 Gold Valley Drive, Ste. 800, Rancho Cordova, CA 95742-7207 | (916) 852-9118 | 20-Oct-2018 | Yes | ASTM C40 C117 C127 C128 C136 C29 C566 C702 | ASTM D2041 | ASTM C31 C39 C138 C143 C172 C231 C1064 C192 C511 C617 C1077 C1231 E329 | ASTM D421 D422 D698 D1140 D1557 D2166 D2216 D2435 D2850 D3740 D4318 D4767 D5084 D6938 E329 | 74 | ||||||||
| United States | California | Rancho Cordova | VALIDATED | Gulf Shore Construction Services | 3383 Fitzgerald Road, Ste. A Rancho Cordova, CA 95742 | (916) 939-4117 | 14-Feb-2020 | Yes | ASTM C117 C123 C127 C128 C136 C29 C40 C88 C142 C566 C702 C136 D75 D2419 D1077 D3744 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C511 C617 C1064 C1231 | ASTM D421 D422 D698 D1140 D1556 D1557 D2166 D2216 D1883 D2419 D2435 D2487 D2488 D2850 D2937 D3740 D4253 D4254 D4318 D4643 D4767 D5084 D6938 | 556 | |||||||||
| United States | California | Rancho Cordova | VALIDATION EXPIRES IN < 180 DAYS | RMA Group | 3150 Fitzgerald Road Rancho Cordova, CA 95742 | (916) 631-7194 | 5-Jan-2019 | Yes | ASTM C40 C117 C127 C128 C136 C29 C88 C123 C131 C142 C535 C566 C702 C1077 C1252 D546 D2419 D3666 D3744 D4791 D5821 E329 | ASTM D1188 D1560 D1561 D2041 D2172 D2726 D2950 D3203 D3666 D4867 D5444 D6307 D6925 D6926 D6927 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C42 C78 C157 C192 C511 C617 C1077 C1231 E329 | ASTM C140 C780 C1093 C1019 C1314 C1552 | ASTM D421 D422 D558 D698 D854 D1556 D1557 D2216 D2419 D2435 D2488 D2844 D3740 D4253 D4254 D4318 D4718 D4829 D6938 E329 | 151 | |||||||
| United States | California | Rancho Cucamonga | VALIDATED | Fenagh Engineering | 9070 Center Avenue Rancho Cucamonga, CA 91730 | 10-Oct-2019 | Yes | ASTM C117 C127 C128 C136 C29 C40 C566 C1077 D75 D2419 D3666 D3744 E329 | ASTM D979 D1188 D2726 D2950 D3666 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C78 C192 C511 C617 C1231 E329 | ASTM C780 C1019 | ASTM D421 D698 D1140 D1556 D1557 D2216 D2487 D2488 D3740 D4318 D6913 D6938 E329 | ASTM E329 E605 E736 | 429 | |||||||
| United States | California | Rancho Cucamonga | VALIDATED | RMA Group | Steve Pitzer | 12130 Santa Margarita Court Rancho Cucamonga, CA 91730 | (949) 521-1048 | spitzer@rmacompanies.com | 1-Mar-2019 | Yes | ASTM C117, C123, C127, C128, C136, C142, C29, C40, C88, C131, C535, C566, C702, C1077, C1252, D546, D2419, D3666, D3744, D4791, D5821, D75, and E329 | ASTM D1188, D1560, D1561, D2041, D2172, D2726, D3203, D3666, D4867, D5444, D6307, D6925, D6926, D6927, and E329. | ASTM C31, C39, C42, C138, C143, C157, C172, C173, C174, C192, C231, C403, C495, C496,C511, C567,C1064, C1140, C78, C617, C1077, C1231, and E329 | ASTM C140, C305, C780, C1019, and C1552 | ASTM D421, D422, D558, D559, D698, D854, D1140, D1556, D1557, D2166, D2216, D2419, D2435, D2487, D2488, D2844, D3740, D4318, D4546, D4829, D4972, D6938, and E329. | ASTM E605. | 206 | ||||
| United States | California | Redding | VALIDATED | Pavement Engineering | 20260 Skypark Drive Redding, CA 96002 | (530)-224-4535 | 30-Aug-2019 | Yes | ASTM C117, C127, C128, C136, C88, C131, C535, C566, C702, D546, D2419, D3666, D3744, D4791, D5821, and E329 | ASTM D1188, D1560, D1561, D2041, D2172, D2726, D2950, D3203, D3666, D4867, D5444, D6307, D6926, D6927, and E329 | ASTM D698, D1140, D1557, D2216, D2487, D4318, D6913, and D6938 | 388 | |||||||||
| United States | California | Riverside | VALIDATED | Construction Testing and Engineering, Inc. (CTE) | Robert Ellerbusch | 14538 Meridian Parkway, Ste. A Riverside, CA 92518 | (951) 571-4081 | 28-Mar-2020 | Yes | ASTM C117 C127 C128 C136 C566 C702 C1077 D2419 E329 | ASTM D2041 D2726 D3203 D3666 D5444 D6307 D6926 D6927 E329 | ASTM C31 C39 C78 C138 C143 C172 C173 C231 C1064 C511 C617 C1077 C1231 E329 | ASTM D421 D422 D558 D698 D854 D1140 D1556 D1557 D1633 D2216 D2487 D3740 D4318 D6938 E329 | 599 | |||||||
| United States | California | Rocklin | VALIDATED | Construction Testing Services | Bradford Quon | 4400 Yankee Hill Road, Building D, Rocklin, CA 95677 | (916) 419-4747 | bquon@cts-1.com | 9-Feb-2020 | Yes | ASTM C117, C127, C128, C136, C29,C40, C88, C131, C535, C566, C702, C1077, C1252, D75, D2419, D3666, D3744, D4791, D5821, and E329. | ASTM D979 D1188 D1560, D1561, D2041, D2726, D2950, D3203, D3666, D4867, D5444, D6307, D6925, D6926, D6927, and E329 | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C192, C511, C617, C1077, C1231, and E329. | ASTM D421, D422, D698, D1140, D1556, D1557, D2166, D2216, D2419, D2487, D2488, D2844, D2974, D4318, D4643, D4718, D4829, D5080, D6938, and E329 | ASTM E605, E736, and E329 | 551 | |||||
| United States | California | Rocklin | VALIDATED | ENGEO, Inc. | 2213 Plaza Drive Rocklin, CA 95765 | (916) 786-8883 | 18-Jul-2019 | Yes | ASTM C40 C117 C127 C128 C136 C566 C702 | ASTM D2041 D2172 D3666 E329 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C511 C617 C1077 C1231 E329 | ASTM D698 D1140 D1557 D2216 D3740 D4318 D4829 E329 | 345 | ||||||||
| United States | California | Roseville | VALIDATION EXPIRED | WRECO | 8331 Sierra College Boulevard, Suite 208 Roseville, CA 95661 | (916)757-6150 | 21-Jul-2018 | Yes | ASTM D421 D422 D698 D1140 D1557 D2216 D2487 D2488 D3740 D4318 D6913 | -17 | |||||||||||
| United States | California | Sacramento | VALIDATION EXPIRED | Kiewit/CTE Quality Control Laboratory at Folsom Dam | 3628 Madison Avenue, Ste. 22, Sacramento, CA | (916) 331-6030 | 28-Oct-2017 | No | ASTM C40 C117 C127 C128 C136 C142 C566 C702 D75 CRD-C104 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C470 C511 C617 C1077 C1231 E329 | ASTM C109 | ASTM D698 D1556 D1557 D2216 D3740 E329 | -283 | ||||||||
| United States | California | Sacramento | VALIDATED | Kleinfelder, Inc. | 3077 Fite Circle Sacramento, CA 95827 | (916) 366-1701 | 3-May-2019 | Yes | ASTM C117, C127, C128, C136, C29, C40, C88, C131, C142, C535, C566, C702, C1077, C1252, D75, D2419, D3666, D3744, D4791, D5821, and E329 | ASTM D1560, D1561, D2041, D2172, D2726, D2950, D3203, D3666, D5444, D6307, and E329 | ASTM C31, C39, C138, C143, C172, C173, C231, C1064, C42, C78, C157, C192, C511, C617, C1077, C1140, C1231, C1542, and E329 | ASTM C140, C780, C1093, C1019, C1314, C1552, and E329 | ASTM D421, D422, D698, D854, D1140, D1556, D1557, D2166, D2216, D2419, D2434, D2435, D2487, D2488, D2850, D2974, D3080, D3740, D4318, D4546, D4767, D4791, D4829, D5084, D6913, D6938, and E329 | ASTM E605 and E736 | 269 | ||||||
| United States | California | Sacramento | VALIDATION EXPIRES IN < 180 DAYS | Krazan & Associates, Inc. | 4320 Orange Grove Avenue Suite E, Sacramento, CA 95841 | 916-564-2200 | 13-Jan-2019 | Yes | ASTM C117 C136 D2419 | ASTM C31 C39 C138 C143 C172 C173 C231 C1064 C511 C617 C1077 C1231 | ASTM D698 D1557 D2216 D2419 D4318 D4829 | 159 |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.