Drawing_Sheet_CO501_-_Amd_0002.pdf
PDF 352 KB Posted
- Attached to
- Portage Lake Revetment Repair
- Solicitation number
- W911XK17B0006
About this file
Drawing Sheet CO501 - Amd 0002
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
S
IZ
E
S U
B M
IT
T E
D B
Y
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
S
A AF
E
Y
Y
T
P S
C O
R P
F
E N
G
IN
E E
R S
D E
T R
IT
D
IS
T R
IC
T
In c r e a s e
P r o f it .S u b m it
V
E C
P 'S
V a lu e
E n g in e e r in g
%PRODUCTION DATA 1%
%PRODUCTION DATA 2% %PRODUCTION DATA 3% %PRODUCTION DATA 4%
W
X K -1
-B -0
A N
S I
D
U
O P
T
IO
N
P H
IL
L
IP
R
O
U
O P
X
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D E
T R
O
IT
D
IS
T R
IC
T
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E
M A
N
IS
T E
E C
O U
N T
Y
O N
E K
A M
A
M I
P O
R T
A G
E L
A K
E H
A R
B O
R
N Z
A G
E R
B
C O
E S R
E V
IE
W F
E B of Engineers
US Army Corps
B
C O
E S R
E V
IE
W J
U N
N O
R T
H S
O U
T H B
R E
A K
W A
T E
R R
E P
A
IR
S
J
U L
Y
F
IN
A L R
O U
T
IN
G
A J
IM
E N
E Z
B
K O
R Z
E T
Z
J
U L
Y
R E
A D
Y T
O A
D V
E R
T
IS
E J
U L
Y
CERTIFIED FINAL - READY TO ADVERTISE
CO501
R E
Q U
IR
E D D
E T
A
IL
S
#4 BARS @ 18" O.C., TOP & BOTTOM
SHEET PILE FILL, M.D.O.T. 4AA AGGREGATE
EXISTING CONCRETE CAP
M.D.O.T. 21AA AGGREGATE
LONG TO SUPPORT CONCRETE IN PAN
OUTSIDE PAN OR TIE TWO #6 BARS 18"
EXTEND TWO BOTTOM BARS INTO EACH
#5 BARS @ 12" O.C.
5'
2" 3"
1/8" PER FOOT
CO301
TYPICAL CONCRETE CAP DETAIL
CO501 SCALE: 1"=1'-0"
CO501 SCALE: 1-1/2"=1'-0"
1/2"
3"
TOP OF REQUIRED CAP
3" CLEAR (TYP.)
1/2"
1"
CO501
TYPICAL REQUIRED SHELF ANGLE DETAIL
SCALE: 1"=1'-0"
18" LONG TO SUPPORT CONCRETE IN PAN
OUTSIDE SSP PAN OR TIE TWO #6 BARS
EXTEND TWO BOTTOM BARS INTO EACH
CONCRETE CAP
REQUIRED REINFORCED
SHELF ANGLE A36 STEEL
REQUIRED L8x8x1/2
4 1/2"
2"
A1
CO101 "=1'4
SCALE:
NOTE:
ELEV. +7 LWD
INCREASE SLUMP UP TO 6"
RANGE PLASTICIZER MAY BE ADDED TO
6AA AGGREGATE AIR ENTRAINED MID
M.D.O.T. GRADE D 4500 P.S.I. CONCRETE
C L SSP
NOTE: PLACE AT EXISTING MONOLITH JOINTS
CAP
TO PLACEMENT OF CONCRETE
INSTALL BOND BREAKER PRIOR
SCALE: 1"=1'-0"
5+00 TO 17+00 = 7' LWD
SOUTH SIDE TOP OF SSP
12+00 TO 17+00 = 6' LWD
5+00 TO 12+00 = 7' LWD
NORTH SIDE TOP OF SSP:
200 FEET ALONG SSP WALL
LADDERS TO BE PLACED EVERY
CO101 SCALE: 1"=1'-0"
SPECIAL PILE TERMINATION
EXISTING CONCRETE CAP
L
INTERLOCK
ADDITIONAL WELDED
Z CORNER W/
C SSP
LESS THAN 4"
NOTES:
CONCRETE CAP. SEE NOTE 1.
AS REQUIRED FOR INSTALLATION OF
HORIZONTAL SAWCUT EXISTING CONCRETE
SSP
TYPICAL EXPANSION JOINT DETAIL TYPICAL CONTROL JOINT DETAIL
TYPICAL LADDER ELEVATION
(TYP)
1 1/2" DIA STEEL LADDER RUNG
SEALANT (ON LEVEL SURFACE)
HOT-POURED OR COLD APPLIED RUBBER
FROM TOP OF CONCRETE)
HOT-POURED OR COLD APPLIED
SPACING ONE END GREASED
1/2" DIA. x 1'-6" LONG BAR @ 1'-0"
JOINT FILLER
1/2" PREMOLDED EXPANSION
SHELF ANGLE
NOTE: PLACE NO MORE THAN 50 FEET APART
EQUAL TO SSP
TIP ELEVATION
INTERLOCK
WELDED
PIPE PILE W/
ASTM A 572, GR 50
O.C.(TYP.)
SPACED @ 5'-0" MAX.
F3125, GRADE A325 BOLT
REQUIRED (1) 3/4" DIA. ASTM
APPROVAL BY THE COR.
SUBMITTAL AND
FILLED. REQUIRED
GROUT VOID TO BE
BAR GRAB RAIL (TYP.)
REQUIRED 1 1/2" DIA.
2'-5 1/2"
REQUIRED SSP WALL
SAFETY ORANGE TO LWD
COATS OF INTERNATIONAL
GRAB BAR AND RUNGS 2
PAINT SSP LADDER WELL,
A6
CO501
SCALE: 1"=1'
A9
CO501
SCALE: 1"=1'
DETAIL
TYPICAL GRAB RAIL
TYP
1 TYP
(SEE NOTE 2)
CONCRETE ANCHOR
REQ'D POST INSTALLED
7"
6"
(SEE NOTE 2)
CONCRETE ANCHOR
REQ'D POST INSTALLED
4" MIN. (TYP.)
7" (TYP.)
PLATE (TYP.)
REQ'D 7"x7"x1/4" THICK
1.5" (TYP.)
REQ'D SSP
DETAIL
TYPICAL GRAB RAIL
CO501
A9
CO501
A9
CO501
A7
CO501
A7
GRAB BAR (TYP)
REQUIRED 1 1/2" DIA
TO LWD
SAFETY ORANGE
INTERNATIONAL
COATS OF
AND RUNGS 2
WELL, GRAB BAR
PAINT SSP LADDER
TYP
3/16"
PLACEMENT
REQUIRED IN SSP FOR
RUNG (TYP) HOLE
1 1/2" DIA STEEL LADDER
OR BELOW -3.0' L.W.D.
BOTTOM RUNG TO BE AT
2"
GALVANIZED.
318, BE AN EPOXY TYPE, AND HOT DIPPED
500 LBS. ANCHOR SHALL BE DESIGNED PER ACI
CAPACITY OF 500 LBS AND TENSION CAPACITY OF
2. CONCRETE ANCHOR SHALL HAVE A SHEAR
CONCRETE CAP IS +6.5.
AREA OF +6.0 SO THAT FINAL GRADE OF
CONCRETE CAP IS +7.0. NO SAWCUT REQUIRED IN
WALL IN +7.0 AREA SO THAT FINISH GRADE OF
+7.0 TO +6.0 LWD. HORIZONTAL SAWCUT EXISTING
1. TOP OF EXISTING WALL TRANISTIONS FROM
P K
F Y
A M
D e ta il s C
O .d g n
A U
G
A M
R E
M O
V E
N O
R T
H S
ID
E
T E
X T O
N D
E T
A
IL
File details come from the government source that posted it. Updated .